Loading...
HomeMy WebLinkAboutNCG551466_Compliance Evaluation Inspection_20180206K. Water Resources Environmental Qtu lity February 6, 2018 Richard F. Masselli 3313 Mt. Zion Church Road Mebane, NC 27302 ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER hiteilin Dirc�tor RECEIVED/DENR/DWR FEB 13 2018 Water Resources Subject: Compliance Evaluation Inspection Permitting Section Single Family Wastewater Treatment System Permit No. NCG551466 Orange County Dear Mr. Masselli: On January 22, 2018,. Mitch Hayes from the Raleigh Regional Office visited your single-family residence (SFR) wastewater treatment system to evaluate compliance with the above permit to discharge wastewater. The checked boxes below show what conditions were noted at your facility: ❑ In compliance: You are reminded to regularly maintain the chlorine disinfection and dechlorination systems, have the effluent sampled once a year, and have the septic tank pumped out every 3 to 5 years. Your good record of operation and meeting the permit requirements is highly commended. ❑ Your home is improperly plumbed: Some of the wastewater discharges are going directly to the environment without first passing through the treatment system. This must be corrected immediately. Please submit a schedule to this office within 30 days of receipt of this letter that states your plan for correcting this deficiency. The work is to be completed within the next 3 months. ❑ Disinfection: Your system is lacking disinfection, either chlorine tablets or a W light system. New rules put into place on August 1, 2007 require all SFR systems to have a means of disinfection (and dechlorination when chlorine tablets are used to disinfect, if the system was installed since that date). Since your system had no disinfection, the installation is to include a chlorine tablet dispenser, a contact chamber capable of providing a minimum 30 -minute contact time, and another tablet dispenser that will hold dechlorination tablets. Please submit a schedule to this office within 20 calendar days of receipt of this letter that states your plan for correcting this deficiency. ❑ Treatment tablets missing or are wrong kind: You are responsible for always having chlorine tablets and dechlorination tablets (if a required part of your system) in place. They must be the kind for wastewater treatment and not for swimming pools. ❑ Dechlorination: Your system was installed after August 1, 2007, so must have a means of dechlorination located downstream of the chlorinator and its contact chamber. See Disinfection paragraph above. Please submit a schedule to this office within 20 calendar days of receipt of this letter statingyourplan for correcting this deficiency. -�:_ ''Nothing Compares"-_-... Division of Water Resources, Raleigh Regional Office, Water Quality Operations Section http:%/portal.ncdenr.org/web/wq/aps 1628 Mail Service Center, Raleigh, NC 27699-1628 Phone: (919) 791-4200 Location: 3800 Barrett Drive, Raleigh, NC 27609 Fax: (919) 788-7159