HomeMy WebLinkAboutWQ0001664_Adjusted Daily Sewage Flow Rate Approval_20180222a;.
Water Resources
ENVIRONMENTAL QUALITY
February 22, 2018
Bryce Mendenhall, VP of Operations for NC & TN
Carolina Water Service, Inc. of North Carolina
4944 Parkway Plaza Boulevard, Suite 375
Charlotte, NC 28217
Subject: Adjusted Daily Sewage Flow Rate Approval
Belvedere Plantation (WQ0001664)
Pender County
Dear Mr. Mendenhall:
ROY COOPER
Governor
MICHAEL S. REGAN
secreta,y
LINDA CULPEPPER
Interim Director
On December 11, 2017, the Division of Water Resources (Division) received an adjusted daily sewage
flow rate (flow reduction) request that would apply to all permitted but not yet tributary residential
connections and all future residential connections within the Belvedere Plantation WWTF service area.
In accordance with 15A NCAC 02T .0114(f)(2), the Division has evaluated the request as well as
additional information received on February 2, 2018, and based on the data submitted and the Division
of Water and Infrastructure (DWI) guidance, the Division hereby approves for use by the Belvedere
Plantation WWTF an adjusted daily sewage design flow rate with the following conditions:
• The flow reduction is applicable to residential single family dwellings only.
• The minimum flow for 1 and 2 bedroom dwellings shall be 130 gallons per day.
• Each additional bedroom above two bedrooms shall increase the volume by 65 gallons per day
per bedroom.
• This flow reduction shall not apply to sewer extension applications and/or permits for any other
public or private organizations whose wastewater flows are or might become tributary to
Belvedere Plantation collection system (WQCS00331).
Future sewer extension applications should be made using the flow reduction amount stated above. All
other aspects of the permitting process remain unchanged, and all applications must be in compliance
with the statues, rules, regulations and minimum design criteria as certified by the owner and engineer.
Regardless of the adjusted design daily wastewater flow rate, at no time shall the wastewater flows
exceed the effluent limits defined in the NPDES Permit for the treatment facility or exceed the capacity
of the sewers downstream of any new sewer extension or service connection(s).
Nothing Compares_
State of North Carolina I Environmental Quality 1 Water Resources
1617 Mail Service Center I Raleigh, North Carolina 27699-1617
919-807-6300
Carolina Water Service, Inc, of North Carolina
WQ0001664
The granting of this flow reduction does not prohibit the Division from reopening, revoking, reissuing
and/or modifying the flow reduction as allowed by the laws, rules, and regulations contained in 15A
NCAC 02T, NCGS 143-215.1, or as needed to address changes in State and/or Federal regulations with
respect to wastewater collection systems protection of surface waters and/or wastewater treatment.
If you have any questions, please contact Christyn Fertenbaugh, P E., at (919) 807-6312, or via email at
ChristVn.Fertenbaugh@ncdenr.gov.
Sincerely,
k-zl� —4�
for Linda Culpepper
Interim Director, Division of Water Resources
by Deborah Gore, Supervisor
Pretreatment, Emergency Response and Collection Systems Branch
Cc: Logan Parsons, E.I., LKC Engineering PLLC (logan@Ikcengineering com)
Wilmington Regional Office, Water Quality Regional Operations
Belvedere Plantation WWTF (WQ0001664)
PERCS (electronic copy)
Page 2 of 8