Loading...
HomeMy WebLinkAboutNC0047384_Drawings_2018021511 U 7 7 I i n n V 0 ry i 0 Q U Q iT V) z Li W Of 1L. 0 r-- U N OL w z In City of Greensboro Water Resources Department T.Z. OSBORNE Water Reclamation Facility Improvements CITY OF GREENSBORO MELVING MUNICIPAL OFFICE BUILDING (MMOB) 300 W. WASHINGTON ST. GREENSBORO, NC 27401 CITY OF GREENSBORO WATER RESOURCES DEPT. 2602 S. ELM—EUGENE ST. GREENSBORO, NC 27406 VOLUME I: ASH PRESS REPLACEMENT VOLUME II: ASH CLARIFIER IMPROVEMENTS 2017-0 1 4A PERMIT SET r1. .S CL -1,I:�boro North Carolina r' �grit_.:.ttura� and Technical garner Park, VICINITY MAP SCALE: 1 "=5000' 1111LIIIIIIf,/' =a' ` 4 53 Olt,js•• ,GINE• QQ-� KA CV\ ff f 11111►►T.`pa .w PROJECT SITE TZO WATER RECLAMATION FACILITY 2350 HUFFINE MILL RD MCLEANSVILLE, NC 27405 A � oF�io p� oFESsio• Oss. ��i�': � � '� �'� .moi. = = �. Qe-, tiy'•. -9 'J� _ �t23669 = = 25802 - '111114 A. BO '/ff ►111111111 - - t //f/11111111 3pN MUS T 1ILITY p �N�O 00 �o o ��► o J W Z S Q IIIII 1 y m BEFORE YOU DIG! CONTACT ONE—CALL CENTER 1-800-632-4949 CHH COG Water 73-2033 C GDOT Traf 73-2606 COG/Guilf 73-2084 COG Wat r 73-5855 Tanks r GOOT St 73-2569 W 0 a J N M, O N C7 M C O t C Q Lo 11 D L, KE 'GVVER SUBS IA iii)ti x x TANKS f '(UREN0.2----­---- {{�'EOiUA IiATiON IA.NK N0.2-- y4 1 I f PRIMARY c-TTa sad( TANK N0,9 - -- R OW EUA{_IZA;;O`� TAN;C 4 �1 SET i LIN G TANK NO.5 0 rn f r � TZO WATER RECLAMATION FACJL(TY MAIN ENTRANCE f E { {I l 1 ADMINISTRATION S�I�(jING X x CONTRACTOR ACCESS ROUTE X i i HOCL SP_ITIL;), FINAL SETTLING 3 J RNAL. SETTLING II TANK N t.I I1 { TP"sNK N(1.2 1 Ii II I I I � is FINAL SETTLING TANKS i DtSTRIB J110N CHAIMSER I i I _- PRIMARY Y SETI�.!NC iI rF�NAIL SILT1LII ; sNA(_ S �`�i_.iNG iA KS I�!G.1 NK NO.3 TANK X50.4 ii FINAL SE i TLING � 1 FINAL Si:_TTLItvG TANK NC,S ), �o TANK NO 6 RAS Ptj41P ! - RAS PUMP STATION: N0." STATION 40.2 - liI t� ERROU CIIi ORIDE ' !::. -.: _ f -CONTRACTOR FILTERS l ..:... f jj STAGING AREA � ..'...N. i Fo c1EA AL STRAGE NG.2 - . .::': : : : I . ,..... .. f F � •. I �3......'.' SOLIDS I - -'HANDLING f' • BUILDING ;.. .......... (' 9IT AND PRE-AERAT!ON `-GRAVITY SL DGEI .:.: _ - n' r r- . S AND TANKS AND PS ..... //CHLORINE f� PUMP SIAPON A TANK f!.. ... `tJf '— "FMC: 4 -----�' HOLDING TANKS - x - PROJECT LOCATION -'" SEE SHEET C-2 RAS PUMP .; ; A I•I0N NLt. � _. SODRIM 4HY1 FACILITY ORIN i ,, TACI i,�`,NK AND �fi�SLAI��:S _ / -x_ x co E 0 CD S C� Of 4 < ¢ < \ < i -1J f FINAL SETTLING 3 J RNAL. SETTLING II TANK N t.I I1 { TP"sNK N(1.2 1 Ii II I I I � is FINAL SETTLING TANKS i DtSTRIB J110N CHAIMSER I i I _- PRIMARY Y SETI�.!NC iI rF�NAIL SILT1LII ; sNA(_ S �`�i_.iNG iA KS I�!G.1 NK NO.3 TANK X50.4 ii FINAL SE i TLING � 1 FINAL Si:_TTLItvG TANK NC,S ), �o TANK NO 6 RAS Ptj41P ! - RAS PUMP STATION: N0." STATION 40.2 - liI t� ERROU CIIi ORIDE ' !::. -.: _ f -CONTRACTOR FILTERS l ..:... f jj STAGING AREA � ..'...N. i Fo c1EA AL STRAGE NG.2 - . .::': : : : I . ,..... .. f F � •. I �3......'.' SOLIDS I - -'HANDLING f' • BUILDING ;.. .......... (' 9IT AND PRE-AERAT!ON `-GRAVITY SL DGEI .:.: _ - n' r r- . S AND TANKS AND PS ..... //CHLORINE f� PUMP SIAPON A TANK f!.. ... `tJf '— "FMC: 4 -----�' HOLDING TANKS - x - PROJECT LOCATION -'" SEE SHEET C-2 RAS PUMP .; ; A I•I0N NLt. � _. SODRIM 4HY1 FACILITY QQ -- O 3" <C1 i Y 0 'GREENSBORO CON FROL POINT 16 'CGS X=797'56.3.01 Y=855009.36NFiUFEz ?r 1— -M, F1 7f OVERALL SITE P SCALE: 1"= 100' 0 100' 200' LEGAL ENTITY: ARCADIS G&M OF �r NORTH CAROLINA, INC. f ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 N Know what's be10W. PLANT NORTH Cali before you dig. CHy of ,0 ensboro0 ` round Locai-es I nforrn ;uests COG Water Resourdes,Dept _;1�5-373-2033 GDOT Traffic Signal''85-373-2606 COG/Guilford (m &o Telecaf 6-373-2084 COG Water. S 8-373-5855 Tanks/Trea4eOtn GDOT Storm Water 6-373--2569 CONTRACTOR ACCESS ROUTE SEALS 4 3 v2. 4- . 1 . KA C�''�P �• rrrrrlil►t►" CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 12/01/20181 PERMIT N0. I DATE I ISSUED FOR I BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: C--1 DESIGNED BY: M. GROSSELL DRAWN BY: W. LEAK CHECKED BY: D. BAIRD SHEET TITLE CIVIL OVERALL SITE PLAN i rte' SCALE: 1 " = 100' CONTRACT SHEET 4 of 48 SHEET c-1 OF Z ORIN i ,, TACI i,�`,NK AND �fi�SLAI��:S _ / -x_ x QQ -- O 3" <C1 i Y 0 'GREENSBORO CON FROL POINT 16 'CGS X=797'56.3.01 Y=855009.36NFiUFEz ?r 1— -M, F1 7f OVERALL SITE P SCALE: 1"= 100' 0 100' 200' LEGAL ENTITY: ARCADIS G&M OF �r NORTH CAROLINA, INC. f ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 N Know what's be10W. PLANT NORTH Cali before you dig. CHy of ,0 ensboro0 ` round Locai-es I nforrn ;uests COG Water Resourdes,Dept _;1�5-373-2033 GDOT Traffic Signal''85-373-2606 COG/Guilford (m &o Telecaf 6-373-2084 COG Water. S 8-373-5855 Tanks/Trea4eOtn GDOT Storm Water 6-373--2569 CONTRACTOR ACCESS ROUTE SEALS 4 3 v2. 4- . 1 . KA C�''�P �• rrrrrlil►t►" CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 12/01/20181 PERMIT N0. I DATE I ISSUED FOR I BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: C--1 DESIGNED BY: M. GROSSELL DRAWN BY: W. LEAK CHECKED BY: D. BAIRD SHEET TITLE CIVIL OVERALL SITE PLAN i rte' SCALE: 1 " = 100' CONTRACT SHEET 4 of 48 SHEET c-1 OF Z IL CD 3 0 I L L / V L L� 2 V C C V. L C d C fk CL C G L a C a 4 0 0) 0 F- m 0 N 5i 0 7 0 0 U c� 0 I U J U w i 0 0 cn U 0 fy a 0 U Q i U ci li m z w LLJ r� c� 0 U U v CL U) J Q) U3 M 1 i I I i I If: I D EXISTING POLYMER SYSTEM (SEE NOTE 1) 16" AND SMALLER DRAINS TO ASH CLARIFIER (VOLUME II) SS —SS SS EXISTING X55 SS RETAINING RETAINING 555 =SS�ss / // wALL SSS ss ASH CLARIFIER II (VOLUMN II) /I I I I I EXISTING DUPLEX FILTRATE CONTROL PANELS II I I FILINAIL I-'UW'I JIHIIiJIV (SEE NOTE 4) I I I I I V I I v� I I TEMPORARY ASH II DEWATERING FACILITIES SS / (VOLUME I) I SS 55 PARTIAL PARTIAL S PLAN SCALE: 1"= 10' 0 10' 20' NOTES: a .1 PLANT NORTH CONTRACTOR STAGING AREA 1. FILL POLYMER CONTAINERS FROM EXISTING POLYMER SYSTEM AND TRANSPORT TO TEMPORARY ASH DEWATERING FACILITIES. 2. CONNECT TEMPORARY TASH PIPING ROUTE TO TEMPORARY ASH DEWATERING FACILITIES. 3. CONNECT TEMPORARY NPW PIPING ROUTE TO TEMPORARY ASH DEWATERING FACILITIES. 4. DISCHARGE FILTRATE AND WASH WATER FROM TEMPORARY DEWATERING FACILITIES TO FILTRATE PUMP STATION. c /mkRCADIs LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's below. Call before you dig. Ctty COG Water R GDOT Traffi COG/Guilfor COG WaterS Tanks/Tre GDOT Storni? res Dept naa:' ''i r%.f 6-373-2569 i 57' SEALS CA S AL 0 0 Oa •tA_ CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 2/01 /20181 PERMIT N0. DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.D001 FILE NAME: DESIGNED BY: C-3 M. GROSSELL DRAWN BY: W. LEAK CHECKED BY: D. BAIRD SHEET TITLE CIVIL TEMPORARY DEWATERING FACILITIES SCALE: 1 " = 10' CONTRACT SHEET 6 OF 48 SHEET C-3 OF 3 L- -----------, 16" AND SMALLER DRAINS TO ASH CLARIFIER (VOLUME II) SS —SS SS EXISTING X55 SS RETAINING RETAINING 555 =SS�ss / // wALL SSS ss ASH CLARIFIER II (VOLUMN II) /I I I I I EXISTING DUPLEX FILTRATE CONTROL PANELS II I I FILINAIL I-'UW'I JIHIIiJIV (SEE NOTE 4) I I I I I V I I v� I I TEMPORARY ASH II DEWATERING FACILITIES SS / (VOLUME I) I SS 55 PARTIAL PARTIAL S PLAN SCALE: 1"= 10' 0 10' 20' NOTES: a .1 PLANT NORTH CONTRACTOR STAGING AREA 1. FILL POLYMER CONTAINERS FROM EXISTING POLYMER SYSTEM AND TRANSPORT TO TEMPORARY ASH DEWATERING FACILITIES. 2. CONNECT TEMPORARY TASH PIPING ROUTE TO TEMPORARY ASH DEWATERING FACILITIES. 3. CONNECT TEMPORARY NPW PIPING ROUTE TO TEMPORARY ASH DEWATERING FACILITIES. 4. DISCHARGE FILTRATE AND WASH WATER FROM TEMPORARY DEWATERING FACILITIES TO FILTRATE PUMP STATION. c /mkRCADIs LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's below. Call before you dig. Ctty COG Water R GDOT Traffi COG/Guilfor COG WaterS Tanks/Tre GDOT Storni? res Dept naa:' ''i r%.f 6-373-2569 i 57' SEALS CA S AL 0 0 Oa •tA_ CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 2/01 /20181 PERMIT N0. DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.D001 FILE NAME: DESIGNED BY: C-3 M. GROSSELL DRAWN BY: W. LEAK CHECKED BY: D. BAIRD SHEET TITLE CIVIL TEMPORARY DEWATERING FACILITIES SCALE: 1 " = 10' CONTRACT SHEET 6 OF 48 SHEET C-3 OF 3 0 T J 0 0 0 0 0 L 0 0 0 0 it N I` F- 0 N N N P 0 O 0 U V) c� �a i i S U LLL i U) W 0 0 V) 0 0 0 of IL a a U �i a� m co z w w c� 0 U U a 0 J W Er - 7) 0 r; a� SLUDGE PUMP ROOM (M-2, M-3, M-4, M-5) � .-..,..�..� _....� ��....-- -- .- .. � ._ .111... ...._..,_.. — L1 ................ � y I F ........... ._., l... 1i 0 PROJECT NO.: GRGRN104.DO01 FILE NAME: M-1 j I i DRAWN BY: A. SUMNER CHECKED BY: D. BAIRD i) _1 13 f Yry, � qg I:� SOLIDS HANDLING BUILDING - EL 710.00 SCALE: 1/1611 = 1'-0" CAN COL POLY FEED (M—c -j ASH DEWATERING ROOM (M-6, M-7, M-8, S-1, S-2, S-3) SOLIDS HANDLING BUILDING - EL 724.00 SCALE: 1/16" = 1'-0" 0 8' 16' 32' CANOPY OUTLINE SLUDGE PRESS ROOM (M-11, M-12, M-13, S-4, S-6, S-7) I a SOLIDS HANDLING BUILDING - EL 742.00 A /Am�RC'AkDIS LEGAL ENTITY: . ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL 336--292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's below. Call before you dig. city COG Water R' >res GDOT Traffi COG/Guilfor " COG Water's S Tanks/,' ;ea GOOT Stow 73-5855 73--2569 CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A I 1 12/01/20181 PERMIT I I N0. I DATE I ISSUED FOR I BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: M-1 DESIGNED BY: M. GROSSELL DRAWN BY: A. SUMNER CHECKED BY: D. BAIRD SHEET TITLE MECHANICAL SCALE: 1/16" = 1'-0" ° 8' 16 32'1 SHB KEY FLOOR PLAN SCALE: AS SHOWN CONTRACT SHEET 7 OF 48 SHEET M — 1 OF 13 0 a N 0 L 0 0 0 0 0 0. co In r2 OD 0 0 r7 d 0 0 v) 0 U EXI"STIN-1C 1=Lt," DEMOLISH BIOSOLIDS PIPING AS SHOWN %I,`' PCLYM�R i- .� 722(3.'00' - C A DONEG SUCTION .......... i r . ......... ... . . -int— .- -x1 I -A• P91P'.1►IA AIIt1R AfA%! SHB SLUDGE PUMP ROOM DEMOLITION PLAN EL 710.00 SCALE: 3 /831 = -. 04ARGOLDIS LEGAL ENTITY: �r ARCADIS G&M OF .I� NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 335-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM JL LICENSE NO. C-1869 know what's below. Call before you dig. Clay of;Ge Loccfe�s I S. 5 ' COG Water R Y Ves GDOT Traffic„r; ; COG/Guilfor. COG Water;. S Tanks/Te GDOT Ston atm, SEALS CArrrr,r RO S 01 3 60 GINA �'�.,� �fKAtCN�;.��• CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 2/01/2018 PERMIT r NO. I DATE I ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.D001 FILE NAME: M-2 DESIGNED BY: M. GROSSELL DRAWN BY: A. SUMNER CHECKED BY: D. BAIRD SHEET TITLE MECHANICAL SHB -- SLUDGE PUMP ROOM DEMOLITION PLAN EL 710.00 SCALE: AS SHOWN CONTRACT SHEET B OF 48 SHEET M-2 OF 13 N co QS O U C� 2 Ld W (f] W O N H O Ln C� O d' O ry a_ 0 U a / 0 a 0 T rm LO r� ui E s= 0 N 0 0 cu 0 co U U7 c� Ll v - I / U tti V) w V) 0 N 0 V) 0 0 cr0 0 Q m cn z LU W 0 U U Q ry W Z L SHB SLUDGE PUMP ROOM PLAN EL 710.00 04ARCADIS LEGAL ENTITY: Al ARCADIS G&M OF A NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM L LICENSE NO. C-1869 Know what's below. Call before you dig. Clay of GteerI round COG Water` R6 i^ OSA tv -373-2033 GOOT Traffi -373-2606 COG/Gu i 1 f ar`l -373--2064 COG Water:.'. SE .' � _; .6-373-5855 Tanks/Tr ea �' GOOT Star��M:Wa ' -373-2569 SEALS Arf����, °�iy'�s S INCE Pc'�•`. CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 1 12/01/20181 PERMIT N0. I DATE I ISSUED FOR I BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.D001 FILE NAME: M-4 DESIGNED BY: M. GROSSELL DRAWN BY: A. SUMNER CHECKED BY: D. BAIRD SHEET TITLE MECHANICAL SHB — SLUDGE PUMP ROOM PLAN EL 710.00 SCALE: AS SHOWN CONTRACT SHEET 10 of 48 SHEET M-4 OF 13 CL c G m 0 0 J r; Lo ASH DEWATERING ROOM DEMOLITION PLAN EL 724.00 0 2' 4' 6' NOTES: 1. RELOCATE AND MODIFY ROTARY FAN PRESS AND SCREW CONVEYOR. 2. RELOCATE FLCCCULATOR AND REMOVE CONCRETE PAD. 3. RELOCATE AIR TANK AND PIPING AND REMOVE CONCRETE PAD. 4. RELOCATE TO SLUDGE PRESS ROOM. Know what's below. Call before you dig. SEALS �A H R E 53 t,7) 70 KA CH�;.�• �fl11111Sti►�\ CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A I 1 12/01/20181 PERMIT I I N0. I DATE I ISSUED FOR I BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: POARCADIS PROJECT NO.: GRGRN104.DO01 FILE NAME: LEGAL ENTITY: ARCADIS G&M OF M. NORTH CAROLINA, INC. DRAWN BY: ONE CENTERVIEW DRIVE, SUITE 208 SUMNER GREENSBORO, NORTH CAROLINA 27407 ,1 L, TEL: 336-292-2279 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's below. Call before you dig. SEALS �A H R E 53 t,7) 70 KA CH�;.�• �fl11111Sti►�\ CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A I 1 12/01/20181 PERMIT I I N0. I DATE I ISSUED FOR I BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: M-6 DESIGNED BY: M. GROSSELL DRAWN BY: A. SUMNER CHECKED BY: D. BAIRD SHEET TITLE MECHANICAL SHB — ASH DEWATERING ROOM DEMOLITION PLAN EL 724.00 SCALE: AS SHOWN CONTRACT SHEET 12 OF 48 SHEET M-6 OF 13 C� C cn O n - 0 N 0 0 Li 0 U Ql CL N RELOCATED ELECTRIC PANEL (SEE E -6)— /A f ..._ 1:... :;�.33 a Ln 3" TASH FROM CLARIFIER NO. 2 2 M-8 �_............. - ---- ---..... .... _ _. � a I i I .. R INSTUME " � NT AIR 2" NPW POLYMER MIXER (SEE NOTE 1) 4" TASH — I l BELT FILTER PRESS CONTROL PANEL j -. ... , ._.._.� / Z ASH DEWATERING ROOM PLAN EL 724.00 N OTE: 1. LOCATE AS DIRECTED BY BELT FILTER PRESS MANUFACTURER. Al. EXISTING 2." POLYMER PIPING f `L 7'17POLYMER FLOW METER (TYP) TASH FLOW METER (TYP) -------- BELT _—a -- 1" POLYMER FLANGED SPOOL PIECE (TYP) ROUTE POLYMER .PIPING TO INJECTION POINT PER BELT FILTER PRESS MANUFACTURER'S INSTRUCTION BELT FILTER PRESS MAINTENANCE PLATFORM AND STAIRS (SHEET S-3) 2" NPW 7�,11 3" FLOOR DRAIN 4" TASH 1"POLYMER j III II l PORTABLE EYEWASH STATION JQ 0 IllXxv II I I 3" FLOOR DRAIN II II II POARCADIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's below. Gall before you dig. a City of a round Locates Irt u8sts COG Water Rdes 0 e -373-2033 GDOT Traffi `. a 373-2606 COG/Guilfor' b-373-2064 COG Water S 6-373-5855 Tanks/Ttea F; GDOT Stora -373-2569 SEALS �;2_� '�2yjs FNG 1 N�F • PQ��,. H fill CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 12/01/20181 PERMIT I NO. DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.D001 FILE NAME: M-7 DESIGNED BY: M. GROSSELL DRAWN BY: A. SUMNER CHECKED BY: D. BAIRD SHEET TITLE MECHANICAL SHB — ASH DEWATERING ROOM PLAN EL 724.00 SCALE: 3/8" = 1'-0" CONTRACT SHEET 13 OF 48 SHEET M-7 OF 13 °, n J 0 N 0 0 N }v} a a �, 0 iu a 0 0 M u7 I= 1•- r O N O M �; 0 0 V C9 a I i U w i w z 0 N F, 0 c� 0 0 0 U m z c� a �_ V v a 0 .� 0 sECT�oN .JV11LL. �!/ V � I V 2" POLYMER CL EL 739.17' POLYMER FEED 'MANIFOLD {TYP) 2 NPW CL EL 736.83' FLANGED SPOOL PIECE (TYP OF 2) 2"x1" REDUCER 3" TASH FLOW METER BALL VALVE {TYP) i " POLYMER FLOW METER 4"x3" REDUCER i" POLYMER CL EL 735.83 4" TASH CL EL 733.83' 2" NPW CL EL 730.67' 1" POLYMER CL EL 728.67 3" TASH FROM CLARIFIER N0. 2 CL EL 727.00' 3" TASH FROM CLARIFIER N0. 1 CL EL 725.33' 3" FLOOR DRAIN �. � �� �.� LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUffE 208 GREENS8OR0, NORTH CAROLINA 27407 TEL: 33fi-292-2271 FAX: 336--855-5648 WWW.ARc�wls.CaM LICENSE N0. C-1869 Know what's �eiOW. Call before you dig. city COG Water' R GDOT Traffi COG/Guilfpr COG Wates. S 'tanks/l :,e GDOT 5tpr\ SEALS `,+,��ti�y�C r�rrr��i� i �,. -� M Rp ' �. ��� O� of �'s s i0'• �� �'�. . __ Q2- �q -y • = 4 53 a . I;� • �� o :�� A _ ti i Y � ��i /sFNGIN���P,Q' • ,,���'' `fKA'GH,`,`,���. 373-2569 CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 201 �—�� 4A i 2/01/2018 PERMIT N0. DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 20i 8 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRIV104.D001 FILE NAME: M-8 DESIGNED BY: M. GROSSELL DRAWN BY: A. SUMNER CHECKED BY: D. BAIRD � SHEET TITLE I MECHANICAL SHB — ASH DEWATERING ROOM SECTIONS SCALE: CONTRACT SPIFFY 14 of 48 SHEET M ` S car= � _� �•- �• '� . ._� e<.j f: - .� �• 4 I �.. E.r �' � � ...:m, ,�, I.,«�`, ' ..= � .,� Vie. - �4• '��, .... [ i _ f •a R � •' r _� � � � � LS11 .. jW �. �. R � f ... $ .�� l < �,Q .<' I_. / � , € .. ,.I Q. Q 1� fav �%�-/��...����� Ij y �• �y-b h � €jI �. j f"l�i� - e � E ��� � •• � ,. ,. ..., -;� �._._._.__ ,� 4� 3" TASH FROM CLARIFIER N0. 2 �;.;•;.R:•. '�� \ CL EL 730.33' �•`� - .� � \ e � �Y s� �i`£�..71t� ^��IY1 U�:l-M �EW� IY�. i �A,y �p) _?�y� _ iF£ .�' .� ', 4i t+ _ 1 � � _ � I �� �q " '. / f, i 4 -. - � 1 � i " INSTRUMENT AIR � a - .°' i I � �� � � - f` � ° .x '. i - � .a., r ° -0 � ! e 3 'y 3 k i _ A.. � i I ; . 3 ' fjjjfjf f , A r !'4 it I'b. � • it « . 5 a' I ' r 3 � . ,Y•- k - E � ...._ •..• :. 1=" ,� .- ,. m .�: a__.�..,_M___._��..... sECT�oN .JV11LL. �!/ V � I V 2" POLYMER CL EL 739.17' POLYMER FEED 'MANIFOLD {TYP) 2 NPW CL EL 736.83' FLANGED SPOOL PIECE (TYP OF 2) 2"x1" REDUCER 3" TASH FLOW METER BALL VALVE {TYP) i " POLYMER FLOW METER 4"x3" REDUCER i" POLYMER CL EL 735.83 4" TASH CL EL 733.83' 2" NPW CL EL 730.67' 1" POLYMER CL EL 728.67 3" TASH FROM CLARIFIER N0. 2 CL EL 727.00' 3" TASH FROM CLARIFIER N0. 1 CL EL 725.33' 3" FLOOR DRAIN �. � �� �.� LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUffE 208 GREENS8OR0, NORTH CAROLINA 27407 TEL: 33fi-292-2271 FAX: 336--855-5648 WWW.ARc�wls.CaM LICENSE N0. C-1869 Know what's �eiOW. Call before you dig. city COG Water' R GDOT Traffi COG/Guilfpr COG Wates. S 'tanks/l :,e GDOT 5tpr\ SEALS `,+,��ti�y�C r�rrr��i� i �,. -� M Rp ' �. ��� O� of �'s s i0'• �� �'�. . __ Q2- �q -y • = 4 53 a . I;� • �� o :�� A _ ti i Y � ��i /sFNGIN���P,Q' • ,,���'' `fKA'GH,`,`,���. 373-2569 CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 201 �—�� 4A i 2/01/2018 PERMIT N0. DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 20i 8 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRIV104.D001 FILE NAME: M-8 DESIGNED BY: M. GROSSELL DRAWN BY: A. SUMNER CHECKED BY: D. BAIRD � SHEET TITLE I MECHANICAL SHB — ASH DEWATERING ROOM SECTIONS SCALE: CONTRACT SPIFFY 14 of 48 SHEET M ` S car= � _� DEMOLISH EXISTING CONTROL PANEL AND EQUIPMENT PAD SEE NOTE 2 — XISTI IG POLYMER 11 PUMP CONTROL I 11 `",NEL (TY") all f O 1 I o - - LE 1 Ld W c \yam X=STiNs"� POLYMER FEED ROOM PLAN - EL 724.00 V 4? a m Z SCALE: 1/4" w 1'-0" V) D A, NOTE: 1. * INDICATES EQUIPMENT PAD DIMENSIONS DETERMINED BASED UPON PUMP ANCHOR BOLT SPACING. 2. PERSERVE ALL EXISTING WIRING IN SERVICE AND ROUTE AS DIRECTED BY OWNER. 3. SLOPE DRAINS AT 1/8" PER 1'. • m POLYMER FEED PUMP N0. 1 — 4'-6" 3 M-10 POLYMER PUMP CONTROL PANEL (TYP) POLYMER FEED PUMP NO. 2 — 1.25" UNION (TYP) —1 1.25" 90 DEG BEND TYP 1.25"x1" REDUCER (TYP) EXISTING 2" POLYMER 1" NPT ADAPTER (TYP) <' TO ASH ROOM 1" PRV TYP EXISTING 4_= PULSATION DAMPENER (TYP) POLYMER PUMP CONTROL POS YMEP 1" PRESSURE INDICATOR (TYP) PANEL (TYP) -- - - 1 5"x1�" REDUCER (TYP) - _ - I 1 M-10 EXISTI r. co i C LL i C a L v im 0 J r 0 C 0 r a L a� CG E V) P n d Q QJ E 4- cp 0 i� 0 V) 0 U c� 0 i i U W i V) t w U) 0 N r 0 CD 0 q, n m z w w Ir0 U U d V) Ld CREATE 40" x 40" HOLE IN WALL DEMOLISH AIR HANDLING EQUIPMENT DEMOLISH AIR SCRUBBER EQUIPMENT DEMOLISH DEWATERED SLUDGE DISCHARGE CHUTE DEMOLISH BELT CONVEYOR I V 1111 PIPING DEMOLISH EXISTING GRIT REMOVAL EQUIPMENT AND PIPING TYP SLUDGE PRESS ROOM DEMOLITION PLAN - EL 742.00 jA/-kR0A,D1S LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855--5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Be' Know whars below. Cal[ before you dig. City of round Locates In uests COG Water `es -373-2033 GDOT Traffl -373-2606 COG/Guilfor. -373-2084 j COG WateO S ,. 6-373-5855 I Tanks/T�.e GDOT Star*.;��Wla `' -373-2569 SEALS '0 � � r 2 • .NGIN6f' Q- CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 2/01/2018 PERMIT NO. DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN 104.D001 FILE NAME: M-11 DESIGNED BY: M. GROSSELL DRAWN BY: A. SUMNER CHECKED BY: D. BAIRD SHEET TITLE MECHANICAL SHB — SLUDGE PRESS ROOM DEMOLITION PLAN EL 742.00 SCALE: AS SHOWN CONTRACT SHEET 17 OF 48 SHEET M -1 1 OF 13 Go C) C14 E Z3 U) ui E C2 0 U) U V) 0 0 0 51 m Uj Lj cr- 0 Li - 0 cu cl. U) Z) ID U) O SEAL GAP BETWEEN WALL OPENING AND CONVEYOR SEE DETAIL SHEET S-6 - 4 j I" NPW 3" THICKENED SLUDGE DRAIN (DOWN) 1" TEE REINSTALL EXIST 1" WATER HAMMER ARRESTER REINSTALL EXIST 1" PRESSURE REGULATOR-" 1.5"x1" REDUCER 1.5" ELBOW, 1.5" BALL VALVE IN VERTICAL - 1.5" TEE 1.5" BALL VALVE 4 a . ...... ...... EQUIPMENT PAD SEE NOTE 5 KX - X 1 f REPAIR FLOOR 6PLY AIR TO, OPENING (SEE FLOCCULATOR DETAIL, SHEET S-5) 1x). !N p 3" THICKENED 6'- 7 1/2" SLUDGE C, CL EL 752.00' 6" FILTRATE DRAIN (DOWN) PROPOSED 3" FEED PIPE "'- EQUIPMENT PAD RELOCATED FLOCCULATOR - 1.5" POLYMER UP TO EXIST FLANGED METER CONNECTION 3" THICKENED SLUDGE UP TO EXISTING FLANGED METER CONNECTION AL III I U 111 0 KI./ --------------- RELOCATED AIR TANK rt ER m RELOCATED CONTROL PANEL II EQUIPMENT PAD I t 7-- 3 n E -�NG S" EXISTING R FLOOR r2 R, DRAIN 0 0 . .......... 1.5" 90 DEG BEND (TYP) ! I[ !2 -13 �0 F 3 7-A,11 M Hi .1-2 .1 A .......... SLUDGE PRESS ROOM PLAN EL 742.00 / )10 2- 4' 6* SCALF: 3/ 8 1'—Off !2!!!!T NOTES: 1. REINSTALL EXISTING ROTARY FAN PRESS AND RELATED EQUIPMENT. 2. REUSE EXISTING PIPING TO EXTENT POSSIBLE AND PROVIDE NEW PIPING TO COMPLETE INSTALLATION UNLESS SPECIFIED ELSEWHERE. 3. CONVERT PRESS FOR BIOSOLIDS DEWATER AS SPECIFIED. 4. * INDICATES EQUIPMENT PAD DIMENSIONS DETERMINED BASED UPON, EQUIPMENT ANCHOR BOLT SPACING. 5. EQUIPMENT PAD WIDTH EQUALS SKID OF ROTARY FAN PRESS PLUS 2". c lakRCImOIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Knowwhat's below. Call before you dig. ctty COG WateO R1 &:es,,D —3 –373-2033 GDOT Traffi6-373-2606 COG/Guilfor A –373-2084 COG Water*, S –373-5855 Tanks/-*i,'P'e GDOT Stor�''�'W"' –373-2569 SEALS I \A CAR "le 0 % 3 053 k eP A- KA CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 1 12/01/20181 PERMIT I I NO. I DATE I ISSUED FOR I BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: INSTRUMENT AIR TO ROTARY FAN PRESS JUNCTION BOX . ..... . .... ... .. .. ..... .. .. .... ..... .. .. . .... .. .. .. FILE NAME: RELOCATED AIR TANK rt ER m RELOCATED CONTROL PANEL II EQUIPMENT PAD I t 7-- 3 n E -�NG S" EXISTING R FLOOR r2 R, DRAIN 0 0 . .......... 1.5" 90 DEG BEND (TYP) ! I[ !2 -13 �0 F 3 7-A,11 M Hi .1-2 .1 A .......... SLUDGE PRESS ROOM PLAN EL 742.00 / )10 2- 4' 6* SCALF: 3/ 8 1'—Off !2!!!!T NOTES: 1. REINSTALL EXISTING ROTARY FAN PRESS AND RELATED EQUIPMENT. 2. REUSE EXISTING PIPING TO EXTENT POSSIBLE AND PROVIDE NEW PIPING TO COMPLETE INSTALLATION UNLESS SPECIFIED ELSEWHERE. 3. CONVERT PRESS FOR BIOSOLIDS DEWATER AS SPECIFIED. 4. * INDICATES EQUIPMENT PAD DIMENSIONS DETERMINED BASED UPON, EQUIPMENT ANCHOR BOLT SPACING. 5. EQUIPMENT PAD WIDTH EQUALS SKID OF ROTARY FAN PRESS PLUS 2". c lakRCImOIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Knowwhat's below. Call before you dig. ctty COG WateO R1 &:es,,D —3 –373-2033 GDOT Traffi6-373-2606 COG/Guilfor A –373-2084 COG Water*, S –373-5855 Tanks/-*i,'P'e GDOT Stor�''�'W"' –373-2569 SEALS I \A CAR "le 0 % 3 053 k eP A- KA CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 1 12/01/20181 PERMIT I I NO. I DATE I ISSUED FOR I BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: M-12 DESIGNED BY: M. GROSSELL DRAWN BY: A. SUMNER CHECKED BY: D. BAI RD SHEET TITLE MECHANICAL SHB - SLUDGE PRESS ROOM PLAN EL 742.00 SCALE: AS SHOWN CONTRACT SHEET 18 OF 48 SHEET M-12 OF 13 wil 2" FLANGI 2"x1.5" REDUCER CORED OPENING (TYP) 14" CENTRATE DRAIN 14"x6" TAPPING SLEEVE SECTION SCALE: 3/8" = 1'-0" rvr.�—�w.rt �•� ♦rr+�sr EXISTING 1" AIR C._ EL 756.63, _LOCATED ROTARY FAN LESS CONTROL PANEL 42.00' R EW. - � � I POARCADIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know whars below. Call before you dig. CHy of G ergs . ' ro COG Water RF`" : es -373-2033 GDOT Traffi-373--2606 COG/Guilfork -373-2084 COG Water. S ` ': .. ' 6-373-5855 Tanks/Thea, y '' GOOT Ston a " -373--2569 SEALS GiNe 4 . ' • KA C'��P`�• "1811111401" CITY CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A i 12/01/20181 PERMIT N0. I DATE I ISSUED FOR I BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: M-13 DESIGNED BY: M. GROSSELL DRAWN BY: A. SUMNER CHECKED BY: D. BAIRD SHEET TITLE MECHANICAL SHB — SLUDGE PRESS ROOM SECTIONS SCALE: AS SHOWN CONTRACT SHEET 19 of 48 SHEET M— 1 3 OF 13 SHB -ASH DEWATERING ROOM DEMOLITION PLAN - EL 724.00 SCALE: 3/8" = 1'-0" * DIMENSIONS DETERMINED BY BELT FILTER PRESS MANUFACTURER. Know. whaft holoW. Call before you dig. CRY of 6 ; L COG Water '.. GDOT Traff COG/Guilf❑ COG Water Tanks/Tr GOOT Stare SEALS uuu,i E'sSA(5j �>, �•..�i GINEF.R.•'<V\l�U S�, A gw'D"`� SEAL NOT VALID UNLESS SIGNED AND DATED CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 2/01/2018 PERMIT NO. DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: PROJECT NO.: FILE NAME: DESIGNED BY: DRAWN BY: CHECKED BY: I SHEET TITLE FEBRUARY 2018 GRGRN 104.DO01 S-1 L. BOWE L.BOWE R. KOLODZAIKE STRUCTURAL SHB -ASH DEWATERING ROOM DEMOLITION PLAN EL 724.00 SCALE: AS SHOWN CONTRACT SHEET 20 OF 48 SHEET S— 1 OF 7 PARCALDIS ,r J� LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 L TEL: 336-292-2271 FAX: 336-855-5648 l 11WWW.ARCADIS.COM IF LICENSE NO. C-1869 Know. whaft holoW. Call before you dig. CRY of 6 ; L COG Water '.. GDOT Traff COG/Guilf❑ COG Water Tanks/Tr GOOT Stare SEALS uuu,i E'sSA(5j �>, �•..�i GINEF.R.•'<V\l�U S�, A gw'D"`� SEAL NOT VALID UNLESS SIGNED AND DATED CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 2/01/2018 PERMIT NO. DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: PROJECT NO.: FILE NAME: DESIGNED BY: DRAWN BY: CHECKED BY: I SHEET TITLE FEBRUARY 2018 GRGRN 104.DO01 S-1 L. BOWE L.BOWE R. KOLODZAIKE STRUCTURAL SHB -ASH DEWATERING ROOM DEMOLITION PLAN EL 724.00 SCALE: AS SHOWN CONTRACT SHEET 20 OF 48 SHEET S— 1 OF 7 0 rX SEE SECTION C/S-3 FOR TYPICAL CURB REINFORCING L3"x3"x1 /4" W/ (2) 1/2" DIA BOLTS (TYP) 0 1' 2' SHORT SLOT HOLES AT TOP OF STRINGER (TYP) WELD CLIP ANGLE TO 3/16" END CHANNEL - (TYP) I I 4"x4"x1/4" CAP PLATE DETAIL .3 6" 0 1' 2' 1" ALUMINUM PLANK GRATING L3"x2"x1 /4" LLV W/ 1/2" DIA SLEEVE ANCHORS EMBEDDED 1 1/2" IN CMUL LIGHTWEIGHT<: CONCRETE FILL s 1 2� STAIR SECTION ALUMINUM HANDRAIL TOP PLATFORM ELEV 728.50' C1Ox15.3 (TYP) TOP CURB ELEV 725.50' i`iI` r G C/0i n S-2 / 0 1' 2 4' TOP PLATFORM ELEV 728.50' TOP CURB ELEV 725.50' X I s. 1= LOOK j 12.4.00' NOTCH GRATING AT - ALUMINUM HANDRAIL POSTS (SEE MOUNTING DETAIL SHEET S-5) C1Ox15.3 (TYP) 8T's 011'=7'-4" D o-- ---- S-3 I � HSS 3x3x1 /4 \ (TYP)1" NON -SHRINK GROUT (TYP) _ o 6"x6"x 1/4" BASE PLATE ON 1" NON -SHRINK GROUT w/ (4) 1/2" DIA EXPN ANCHORS STAIR SECTION f f � - - 3'-4" - 8" STEPS 2 Ya" ALUMIMUM PLANK GRATING 2 S-3 V-6- LOW POINT TR ELEV 724.17' 7'-0" OA w I 0 3 #5 @6" c/c • • z ° (PLACE ITOP #5 - - - - - It w 3" FROM TOP 5 a OF CURB) Of 0 #4 VERTICALS Uj U) >_10" /c MAX. • • a m (TYP EA, SIDE) ANCHOR BOLT AS REQUIRED BY PRESS MANUFACTURER PIER DETAIL -PLAN L3"x3"x1 /4" W/ (2) 1/2" DIA BOLTS (TYP) 0 1' 2' SHORT SLOT HOLES AT TOP OF STRINGER (TYP) WELD CLIP ANGLE TO 3/16" END CHANNEL - (TYP) I I 4"x4"x1/4" CAP PLATE DETAIL .3 6" 0 1' 2' 1" ALUMINUM PLANK GRATING L3"x2"x1 /4" LLV W/ 1/2" DIA SLEEVE ANCHORS EMBEDDED 1 1/2" IN CMUL LIGHTWEIGHT<: CONCRETE FILL s 1 2� STAIR SECTION ALUMINUM HANDRAIL TOP PLATFORM ELEV 728.50' C1Ox15.3 (TYP) TOP CURB ELEV 725.50' i`iI` r G C/0i n S-2 / 0 1' 2 4' TOP PLATFORM ELEV 728.50' TOP CURB ELEV 725.50' X I s. 1= LOOK j 12.4.00' NOTCH GRATING AT - ALUMINUM HANDRAIL POSTS (SEE MOUNTING DETAIL SHEET S-5) C1Ox15.3 (TYP) 8T's 011'=7'-4" D o-- ---- S-3 I � HSS 3x3x1 /4 \ (TYP)1" NON -SHRINK GROUT (TYP) _ o 6"x6"x 1/4" BASE PLATE ON 1" NON -SHRINK GROUT w/ (4) 1/2" DIA EXPN ANCHORS STAIR SECTION f f � - - 3'-4" - 8" STEPS 2 Ya" ALUMIMUM PLANK GRATING 2 S-3 V-6- LOW POINT TR ELEV 724.17' 7'-0" OA 717 SUPPORT PIER (TYP), QUANTITY AND kOCATION AS REQUIRED BY BELT LTER PRESS MANUFACTURER 0 3 0 0 S-3 N ACHOR BLT (TYP) 12" HIGH OINT TRENCH TYP ELEV 724.83' w o 0 0 — — 2-41 "— 1' / NEW 1'-6"x 4'-6" FLOOR OPENING SLOPE o i PLATFORM ANDI STAIRS NOT SHOWN FOR CLARITY. ° SEE THIS SHEET; FOR DETAILS. °' LIGHTWEIGHT t� N CONCRETE FILL AS RE UIRED Ea I I I r - - -- -- -- -- -- ___ Q BASED I EXTEND NEW CURB -/ - - --- --- - -- - -- - -- AS REQUIRED TO �I ON BELT FILTER PRESS -- — _ _ - —J ------ _4 1 ` MANUFACTUER n , ENCASE EXISTING ROLL UP DOOR 1 1`I ^ TRACK ^ - - - - r ..... . (TYP EA SIDE) Z -- - - - - 1l/f= - - _ % - ✓ _ L/ zZZ SHB -ASH DEWATERING ROOM PROPOSED PLAN - EL 725.50' 0 2' 4' 6' fl fl x 1/4" II� ALUMINUM BASEPLATE HANDRAIL I W/ (4) 1/2" DIA EXPN ANCHORS (TYP 3 PLACES) HSS 3x3x1/4 (TYP) 1" NON -SHRINK GROUT (TYP) ALU INUM HAN RAIL L3"x3"x1 /4" w/ 1/2" DIA EXPN ANCHORS EMBEDDED 3 1/4" IN SLAB TOP OF LIGHTWEIGHT CONIC FILL ELEV 725.50' 0 0 0 5 SECTION S-2 0 1' 2' 5 T ® 11"=4'-7" 6 R 0 6" 1" ALUMINUM - PLANK GRATING TOP PLATFORM ELEV 728.50' HSS 3x3x1/4 (TYP) C10x15.3 (TYP) 5 4 S-2 S-2 TOP CURB 1" NON -SHRINK ELEV 725.50' GROUT (TYP) LIGHTWEIGHT fa NISH FLOOR CONCRETE FILL LL -V 72ZOO' SEE SECTION B/S-3 FOR TYPICAL 3 STAIR SECTION CURB REINFORCING S-2 0 1' 2' 4 18'-9" o/o 6"x6"x 1/4" BASE PLATE W/ (3) 1/2" EDGE OF DIA EXPN CURB ANCHORS HSS 3x3x1/4 (TYP) 1" NON -SHRINK 0 0 GROUT (TYP) 1 1/2" 1AMO%DIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's below. Call before you dig. Ctty of 6p&e sbo AJ ground Locafgs in. uesfs COG Water ReaQtTrces.Dept . -373-2033 ODOT Traffic�ffal 373-2606 COG/Guilforh,,Cj1/T@1', -373-2084 i ti o i. - COG Water S y, Jr,J -373-5855 Tanks/Teak ,3 z GDOT Sto-373-2569 SEALS noun iii 02 f SEAL NOT VALID UNLESS SIGNED AND DATED CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 2/01/2018 PERMIT 3/16" 6 NO. DATE ISSUED FOR BY 4 SECTION COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. S-2 0 1 2' DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: S-2 DESIGNED BY: L. BOWE DRAWN BY: L. BOWE 11'-0" CHECKED BY: R. KOLODZAIKE 6.. SHEET TITLE STRUCTURAL L3"x2"x1 /4" SHB -ASH DEWATERING ROOM PLATFORM -PLAN - EL 728.50' 0 2' 4' 6' 019 SHB—ASH DEWATERING ROOM PLAN, SECTIONS AND DETAILS EL 724.00 SCALE: AS SHOWN CONTRACT SHEET 21 OF 48 SHEEP S-2 OF 7 w I 0 Tn ° - - - - - - - - - - - 717 SUPPORT PIER (TYP), QUANTITY AND kOCATION AS REQUIRED BY BELT LTER PRESS MANUFACTURER 0 3 0 0 S-3 N ACHOR BLT (TYP) 12" HIGH OINT TRENCH TYP ELEV 724.83' w o 0 0 — — 2-41 "— 1' / NEW 1'-6"x 4'-6" FLOOR OPENING SLOPE o i PLATFORM ANDI STAIRS NOT SHOWN FOR CLARITY. ° SEE THIS SHEET; FOR DETAILS. °' LIGHTWEIGHT t� N CONCRETE FILL AS RE UIRED Ea I I I r - - -- -- -- -- -- ___ Q BASED I EXTEND NEW CURB -/ - - --- --- - -- - -- - -- AS REQUIRED TO �I ON BELT FILTER PRESS -- — _ _ - —J ------ _4 1 ` MANUFACTUER n , ENCASE EXISTING ROLL UP DOOR 1 1`I ^ TRACK ^ - - - - r ..... . (TYP EA SIDE) Z -- - - - - 1l/f= - - _ % - ✓ _ L/ zZZ SHB -ASH DEWATERING ROOM PROPOSED PLAN - EL 725.50' 0 2' 4' 6' fl fl x 1/4" II� ALUMINUM BASEPLATE HANDRAIL I W/ (4) 1/2" DIA EXPN ANCHORS (TYP 3 PLACES) HSS 3x3x1/4 (TYP) 1" NON -SHRINK GROUT (TYP) ALU INUM HAN RAIL L3"x3"x1 /4" w/ 1/2" DIA EXPN ANCHORS EMBEDDED 3 1/4" IN SLAB TOP OF LIGHTWEIGHT CONIC FILL ELEV 725.50' 0 0 0 5 SECTION S-2 0 1' 2' 5 T ® 11"=4'-7" 6 R 0 6" 1" ALUMINUM - PLANK GRATING TOP PLATFORM ELEV 728.50' HSS 3x3x1/4 (TYP) C10x15.3 (TYP) 5 4 S-2 S-2 TOP CURB 1" NON -SHRINK ELEV 725.50' GROUT (TYP) LIGHTWEIGHT fa NISH FLOOR CONCRETE FILL LL -V 72ZOO' SEE SECTION B/S-3 FOR TYPICAL 3 STAIR SECTION CURB REINFORCING S-2 0 1' 2' 4 18'-9" o/o 6"x6"x 1/4" BASE PLATE W/ (3) 1/2" EDGE OF DIA EXPN CURB ANCHORS HSS 3x3x1/4 (TYP) 1" NON -SHRINK 0 0 GROUT (TYP) 1 1/2" 1AMO%DIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's below. Call before you dig. Ctty of 6p&e sbo AJ ground Locafgs in. uesfs COG Water ReaQtTrces.Dept . -373-2033 ODOT Traffic�ffal 373-2606 COG/Guilforh,,Cj1/T@1', -373-2084 i ti o i. - COG Water S y, Jr,J -373-5855 Tanks/Teak ,3 z GDOT Sto-373-2569 SEALS noun iii 02 f SEAL NOT VALID UNLESS SIGNED AND DATED CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 2/01/2018 PERMIT 3/16" 6 NO. DATE ISSUED FOR BY 4 SECTION COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. S-2 0 1 2' DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: S-2 DESIGNED BY: L. BOWE DRAWN BY: L. BOWE 11'-0" CHECKED BY: R. KOLODZAIKE 6.. SHEET TITLE STRUCTURAL L3"x2"x1 /4" SHB -ASH DEWATERING ROOM PLATFORM -PLAN - EL 728.50' 0 2' 4' 6' 019 SHB—ASH DEWATERING ROOM PLAN, SECTIONS AND DETAILS EL 724.00 SCALE: AS SHOWN CONTRACT SHEET 21 OF 48 SHEEP S-2 OF 7 ki #4 ADHESIVE DOWELS x 1'-6" 24" c/c INTO EXISTING SLAB (SEE DETAIL B/S-3) CL 6" 724.42' _ TOP BRICK EL 724.00' REMOVE EXISTING CONCRETE AS — REQUIRED–DO NOT DAMAGE EXISTING REINFORCING STEEL. Z a �w J U EXISTING BRICK V-6" CURB 6" • C • C -a WALL CAST DETAIL 2 #6 TOP AND BOTTOM CONTINUOUS (TERMINATE BOTTOM BARS AT PIPE) EL 725.50' /— ADD 2#6 x 4'-0" OVER PIPE DIRECTLY ABOVE BOTTOM BARS ELEV. 724.17' EXIST FLOOR EL 724.00' 2» 2" 2" EL VARIES' > a° v. p ' ° d < 3 SECTION S3 0 3" 6" 9" EL 725.08' EXISTING 3 #7 CONTINUOUS ADHESIVE WATERSTOP (LOCATE AS REQUIRED TO AVOID EXISTING REINFORCING STE[ EXISTING #3 TIES @ 12" C/C LIGHTWEIGHT CONCRETE FILL EL 724.00' %2� SECTION PARCADIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's below. Call before you dig. SEALS \"\uiuurrgi CARO p� �E'ssi6N••. / _ � • e S E Ia //A/uiAl ng SEAL NOT VALID UNLESS SIGNED AND DATED CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A L 1 12/01/20181 PERMIT I I I N0. I DATE I ISSUED FOR I BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. �) DATE: FEBRUARY 2018 i GRATING SUPPORT PROJECT NO.: GRGRN104.DO01 ANGLE – SEE FILE NAME: S-2 1'-0" DETAIL SHEET S-5 CURB PROVIDE STEPS (TYP NORTH AND 2 1/4" GRATING DESIGNED BY: L. BOWE WHERE SHOWNSOUTH SIDES) #4 STIRRUPS IN PLAN DRAWN BY: W. LEAK T/PLATFORM EL 725.50' 12" c/c EL 725.50' EL 728.50' CHECKED BY: R. KOLODZAIKE • 2 1/4" GRATING d. #4 STIRRUPS B EL 725.50' SHEET TITLE I (TYP) EDGE OF (0 I: ® 12" cc S-3 , L/NEW FLOOR I I II I / EL 725.08' STRUCTURAL EL 725.25' a OPENING Of iD �j i APPLY BONDING SLOPE ° ° ' ® d ° I . AGENT (TYP) 724.00' 4 -L 724.00` ( a SHB—ASH CONTINUOUS ADHESIVE CONTINUOUS ADHESIVE ! " °. DEWATERING ROOM WATERSTOP (INSTALL 2 #6 TYP #4 ADHESIVE WATERSTOP (INSTALL ° ` d. d d_ SECTIONS AND DETAILS 3' FROM INSIDE OF CURB) TOP & BOTT DOWELS ® 3" FROM INSIDE OF CURB) EL 7Z4.00 If 6" CONTINUOUS 12" c/c 2 TREADS 2 #6 TYP TOP ` /L ld ° MIN. #4 ADHESIVE DOWELS @ 11" _ & BOTT CONTINUOUS TRENCH °j LIGHTWEIGHT x V-6" ® 24" c/c 1'-10" #4 ADHESIVE DOWELS x CONCRETE FILL (SEE DETAIL "B" THIS SHEET) V-6" ® 24" c/c DRILLED AND GROUTED 4" INTO SCALE: EXISTING CONCRETE (TYP) AS SHOWN c CURB D ETAI L B CURB STEP D ETAI L SECTION CONTRACT SHEET S-3 0 1' 2' 3' S-3 0 1' 2' 3' S-2 0 2' 4' 6' 22 OF 48 NOTE: iiEFEEMI CURB DETAIL TYPICAL FOR NORTH AND S-3 OF SOUTH SIDE OF PRESS SHEET CRY of GT"Insboro Ll ro Locates I us COG Water R' Cgs ;OGpt . f)-37: GOOT Traffi ° —37: COG/Guilfor "-6-37: COG Water. S� —37: Tanks/Treat`, GOOT Storri:Wa e 0 - • —37: SEALS \"\uiuurrgi CARO p� �E'ssi6N••. / _ � • e S E Ia //A/uiAl ng SEAL NOT VALID UNLESS SIGNED AND DATED CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A L 1 12/01/20181 PERMIT I I I N0. I DATE I ISSUED FOR I BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. �) DATE: FEBRUARY 2018 i GRATING SUPPORT PROJECT NO.: GRGRN104.DO01 ANGLE – SEE FILE NAME: S-2 1'-0" DETAIL SHEET S-5 CURB PROVIDE STEPS (TYP NORTH AND 2 1/4" GRATING DESIGNED BY: L. BOWE WHERE SHOWNSOUTH SIDES) #4 STIRRUPS IN PLAN DRAWN BY: W. LEAK T/PLATFORM EL 725.50' 12" c/c EL 725.50' EL 728.50' CHECKED BY: R. KOLODZAIKE • 2 1/4" GRATING d. #4 STIRRUPS B EL 725.50' SHEET TITLE I (TYP) EDGE OF (0 I: ® 12" cc S-3 , L/NEW FLOOR I I II I / EL 725.08' STRUCTURAL EL 725.25' a OPENING Of iD �j i APPLY BONDING SLOPE ° ° ' ® d ° I . AGENT (TYP) 724.00' 4 -L 724.00` ( a SHB—ASH CONTINUOUS ADHESIVE CONTINUOUS ADHESIVE ! " °. DEWATERING ROOM WATERSTOP (INSTALL 2 #6 TYP #4 ADHESIVE WATERSTOP (INSTALL ° ` d. d d_ SECTIONS AND DETAILS 3' FROM INSIDE OF CURB) TOP & BOTT DOWELS ® 3" FROM INSIDE OF CURB) EL 7Z4.00 If 6" CONTINUOUS 12" c/c 2 TREADS 2 #6 TYP TOP ` /L ld ° MIN. #4 ADHESIVE DOWELS @ 11" _ & BOTT CONTINUOUS TRENCH °j LIGHTWEIGHT x V-6" ® 24" c/c 1'-10" #4 ADHESIVE DOWELS x CONCRETE FILL (SEE DETAIL "B" THIS SHEET) V-6" ® 24" c/c DRILLED AND GROUTED 4" INTO SCALE: EXISTING CONCRETE (TYP) AS SHOWN c CURB D ETAI L B CURB STEP D ETAI L SECTION CONTRACT SHEET S-3 0 1' 2' 3' S-3 0 1' 2' 3' S-2 0 2' 4' 6' 22 OF 48 NOTE: iiEFEEMI CURB DETAIL TYPICAL FOR NORTH AND S-3 OF SOUTH SIDE OF PRESS SHEET it 3'-4" nFAAn W -n" N. SLUDGE PRESS ROOM DEMOLITION PLAN - EL 742.00 SCALE: 3/8" = 1'-0" 0 2' 4' 6' SECTION EX.S-! OOR EL 742.00' CA ARCADIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's below. Call before you dig. CRY COG Water F GDOT Traffi CDG/Guilfor COG Water S GDOT SEALS nlnirrri CARq is . J2'' • 11�4 SEAL NOT VALID UNLESS SIGNED AND DATED CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 1 12/01/20181 PERMIT I I I N0. I DATE I ISSUED FOR I BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: S-4 DESIGNED BY: L. BOWE DRAWN BY: W. LEAK CHECKED BY: R. KOLODZAIKE 1 SHEET TITLE STRUCTURAL SHB — SLUDGE PRESS ROOM DEMOLITION PLAN AND SECTION — EL 742.00 SCALE: AS SHOWN CONTRACT SHEET 23 of 48 SHEET S-4 OF 7 EXISTING 8" CMU 4" CMU NEW LINTEL (SEE DETAIL THIS SHEET FILL CAVITY WITH MINERAL WOOL INSULATION CONVEYOR 20 GAGE INTERIOR — METAL PANEL ELEV. 743.33' ELEV. 742.00' D MIN. (2) 3/8" SST BOLTS 1 1/2" DIA. POST CAST BASE FLANGE PLAN (FOR EQUIPMENT MAINTENANCE PLATFORM AND STAIRS) 1 1/2" DIAMETER POST 2 SET SCREWS (OMIT AT REMOVABLE E HANDRAIL) �E SEE PLAN FOR m m ELEVATION AS REQ'D SST ANCHORS SECTION HANDRAIL DETAILS NO SCALE CANOPY EXISTING 4" BRICK 20 GAUGE GALV. REGLET FLASHING / AT TOP OF METAL PANEL. EXTEND 6" PAST SIDES OF METAL SHEET/PANEL 18 GAGE GALVANIZED METAL SHEET/PANEL CUT TO FIT AROUND CONVEYOR. PROVIDE TWO PIECES WITH STANDING SEAM ® JOINT OR PLACE ONE SOLID PIECE AROUND CONVEYOR DURING INSTALLATION. FLANGE PLATE 90' BEND \LANT : KER ROD 3/8" DIA SLEEVE ANCHORS ® 1'-0" c/c (TYP) PROVIDE BEND AT BOTTOM AND SIDES OF PANEL BACKER ROD AND JOINT SEALANT WALL CLOSURE DETAIL @ CONVEYOR 0 , 2• EXISTING 12" CMU 4" CMU L 3 1/2" x GALVANIZED STEEL LINTELS x 4'-0" LINTEL D ETAI L —0" CENTER TO (MAX.) I(— ALUMINUM — RAIL & POST SEE MOUNTING DETAIL THIS SHEET TOEBOARD —FINISHED FLOOR ELEVATION PLACE CONCRETE FLUSH WITH EXISTING FLOOR — #4 DOWELS 0 12" C/C (TYP AROUND PERIMETER OF EQUIPMENT PAD) WITH STANDARD 90' HOOK EMBED DOWELS 4" MIN. INTO EXISTING SLAB EQUIPMENT PAD NOTES - 1. EQUIPMENT ANCHORAGE NOT SHOWN FOR CLARITY. SIZE AND EMBEDMENT OF EQUIPMENT ANCHORAGE SHALL BE DETERMINED BY EQUIPMENT MANUFACTURER. 2. TOP SURFACE OF EQUIPMENT PAD SHALL BE LEVEL. 3. PAD SHOULD EXTEND MINIMUM 6" BEYOND EQUIPMENT LIMITS ON ALL SIDES. 4. USE LIGHTWEIGHT CONCRETE FOR EQUIPMENT PAD UNDER ROTARY FAN PRESS. 4'-1" (x 4'-1") #4 ® 8" c/c 1/2" DIA EXPANSION ANCHORS EMBEDDED 2" MIN IN SLAB ® 12" c/c (4 EACH SIDE) \ - L4"x3" x1/4" LONG LEG VERTICAL (TYP 4 SIDES SLUDGE PRESS ROOM CONCRETE FLOOR REPAIR DETAIL 1" = 1'-0» 0 1/2' 1' z' CQ1I1Q d a. EQUIPMENT PAD DETAIL #4 @ 10" C/C EW, CENTERED IN EQUIPMENT PAD as . . PROJECT NO.: GRGRN104.DO01 4 d DESIGNED BY: dd DRAWN BY: W. LEAK CHECKED BY: a. SHEET TITLE - d STRUCTURAL TOP OF CON J U N 3�4" CHAMFER �— EX. SLAB V III d d a .a a 9 EXISTING SLAB TOP SURFACE SHALL BE FREE OF DETERIORATED CONCRETE, DUST, DIRT, AND ALL CONTAMINANTS PRIOR TO NEW CONCRETE PAD PLACEMENT. 0 1/2' 1' 2' 1/8" x 1" STRAP ANCHORS GRATING — SEE PLANS FOR SIZES GRATING SUPPORT — ANGLE FRAME (1/4" LARGER THAN GRATING DEPTH) GRATING AND ANGLE FRAME MATERIAL SHALL BE IDENTICAL. SECTION GRATING FRAME DETAIL 0 1/2' 1' 2' 00/%R=1S LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's beim. Call before you dig. Ctty of GreenjborA �" round 00004* s Infer uests COG Water ReSPOrces,0epi� -373-2033 GOOT IraffiyL' ig0e1 -373-2606 COG/Guilford �i�¢l, �Cp1 "6-373-2084 COG Water SUi 6-373-5655 - Tanks/T ea �n8 t GDOT Stor-373-2569 SEALS Wiilinii i� S� A• BO��I�� ��m n l nus SEAL NOT VAUD UNLESS SIGNED AND DATED CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 2/01/2018 PERMIT NO. DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: S-5 DESIGNED BY: L. BOWE DRAWN BY: W. LEAK CHECKED BY: R. KOLODZAIKE SHEET TITLE STRUCTURAL SHB — STRUCTURAL DETAILS AS SHOWN CONTRACT SHEET 24 of 48 SHEET S — � OF 7 1. LIVE LOAD: 20 psf GRGRN104.DO01 2. WIND DESIGN DATA: BASIC WIND SPEED: 90 mph L. BOWE DRAWN BY: WIND IMPORTANCE FACTOR: 1.00 R. KOLODZAIKE WIND EXPOSURE CATEGORY: B OCCUPANCY CATEGORY: II 3. EARTHQUAKE DESIGN DATA: SEISMIC IMPORTANCE FACTOR: 1.0 SEISMIC OCCUPANCY CATEGORY: II SPECTRAL RESPONSE ACCELERATION Ss 0.146 %G S1 0.72 %G SITE CLASSIFICATION: C 4. SNOW LOAD: GROUND SNOW LOAD (Pg) 15.0 PSF SNOW LOAD INPORTANCE FACTOR (Is): 1.00 SNOW EXPOSURE FACTOR (Ce): 1.0 THERMAL FACTOR (Ct): 1.2 5. COLATERAL LOADS: WEIGHT OF CONVEYOR AND CONVEYED MATERIALS: TO BE DETERMINED BY CONVEYOR MANUFACTURER. 6. NET ALLOWABLE SOIL BEARING PRESSURE: 2000 PSF, TO BE VERIFIED BY GEOTECHNICAL ENGINEER PRIOR TO CONSTRUCTION OF FOUNDATION. M F m N ZZ 0 0 M BOLLARD (TYP 6 PLACES) (SEE DETAIL SHEET S-7) 0_ 0 z a U 0 O 0 CD I N 32'-0" o/o CANOPY i I ill 4'-6" 23 — — —0.. r} a co 00 ----------- V_ — — — — — — — 1 I I I I 1 I I S-6 I { i I I --------------------- --{—I I I� I I I I I I i I I { V\ \ \ I I I I \\ COLUMN FOUNDATION, COLUMNS I I I AND APPURTENANCES BY j �• �v CANOPY MANUFACTURER (TYP) I CANOPY (ABOVE) I `• I I I I \\ \\ I I I I I \ \ I I I I – -------I------- -- -- \-------------------- – – – – -- --------I------- �z-------------------------- – — -------- ------ --------------- X \ \ I I CONVE\YQR CHUTE -I --------I-- I I -- (ABOVE \\ \\---- I (- --------- 4t --6-- -I I SEE NOTE 2 1 I CONVEYOR \ \ I h— q EXIST 12" NPW \ \ (ABOVE) \ \\ I i i I ELEV. 718.00 I I I I EXIST 14" FILTRATE I ENCASE EXISTING PIPING � \\ \ :�;� .�I AND SCUM INV.\ •' (TYP 3 LOCATIONS) r'•. F.:.:i. (SEE NOTE 5) I � ELEV. 717.25' i .� ; - OXO -- -- -- -- j: 0 BOTT FOOTER xE 1; ' '•� ELEV 720.50'f rL EXIST 4" PW ELEV. 719.50' ------- ---- ---- --- .. I I i P I •,� ,';.." .,.... I �----1 �-I---�� ilk -- Lr--�A �------- FINISH FLOOR j WALL CLOSUREI \,�Ji� 1 r ! _ I I (SEE DETAIL SHEET S-5) /-� ELEV 724.00 N. AARCADIS SHB -CANOPY PLAN - EL 724.00 1 0 2, 4, 6' NOTES: 1. 4'-0" MAXIMUM FOUNDATION WIDTH IN NORTH—SOUTH DIRECTION FOR SOUTHWEST CANOPY COLUMN. 2. 4'-6" MAXIMUN FOUNDATION WIDTH IN EAST—WEST DIRECTION FOR SOUTHEAST CANOPY COLUMN. 3. SPECIAL INSPECTIONS SHALL BE PERFORMED IN ACCORDANCE WITH CHAPTER 17 OF THE 2012 NORTH CAROLINA BUILDING CODE AS FOLLOWS: CONCRETE (FOUNDATION): ITEM 1,3,5,6,8,12 IN TABLE 1704.4 STRUCTURAL STEEL: ITEMS 1,2,3,6 IN TABLE 1704.3 4. BURIED PIPING LOCATIONS ARE APPROXIMATE. CONTRACTOR TO FIELD VERIFY. 5. EXPOSE AND ENCASE BURIED PIPING MINIMUM 6" ABOVE AND ON EACH SIDE WITH EXCAVATION FLOWABLE FILL CONCRETE MIX IN ACCORDANCE WITH NCDOT SPECIFICATIONS TABLE 1000-1. EXCAVATE, ENCASE AND BACKFILL 14" FILTRATE AND SCUM PIPE ADJACENT TO BUILDING TO ELEVATION 720.50 OR HIGHER BEFORE EXCAVATING FOR 12" NPW. PROTECT EXISTING BUILDING FOUNDATIONS. LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's below. Call before you dig. City of f Locate COG Water GOOT Traff COG/Guilfo COG Water. Tanks/T GOOT StonAg SEALS "a 111 np ZOQQ�...... SEA A'4 IiBo � 10 SEAL NOT VALID UNLESS SIGNED AND DATED CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-0141 1 12/01/20181 PERMIT N0. I DATE I ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: S-6 DESIGNED BY: L. BOWE DRAWN BY: W. LEAK CHECKED BY: R. KOLODZAIKE SHEET TITLE 1 STRUCTURAL SHB -CANOPY PLAN EL 724.00 SCALE: AS SHOWN CONTRACT SHEET 25 OF 48 SHEET S-6 OF 7 M 1- 00 N ZZ 0 EXIST FLOOR EL 742.00' SLUDGE CONVEYOR (SEE M—SHEETS) �4 4'-6" EXIST EXTER OR BUILCiNG 'v' L ROOF COUNTER FLASHING TO BRICK WALL WITH PRE—FINISHED METAL COPING (MIN 16 GA) TO MATCH CANOPY STRUCTURE (BY CANOPY MANUFACTURER) CONVEYOR SUPPORT LOCATION AND LOAD TO BE DETERMINED BY CONVEYOR MANUFACTURER WALL CLOSURE (SEE DETAIL SHEET S-5) EXIST FLOOR EL 724.00' 1 . 4 .�- a 1 Q --- Q 6 4 6 ( O do A a EXIST F00 ER EL 720.50' LJ CANOPY SECTION 12'-0" BOLLARD (BEYOND) (SEE DETAIL SHEET THIS SHEET) COLUMN ANCHOR BOLTS (BY CANOPY MANUFACTURER) PRE—ENGINEERED METAL CANOPY CONVEYOR CHUTE COLUMN (BY CANOPY MANUFACTURER) EX',ST CONCRETE PAVEMENT LEV. 723.5'± BOTTOM OF FOUNDATION NO LOWER THAN ELEV. 719.67' (SEE NOTE 1) CANOPY FOUNDATION (BY CANOPY MANUFACTURER) 36" HIGH ALUMINUM FASCIA PANEL BOTTOM CANOPY EL 748.00' w U Z Q o� la W N U DOWNSPOUT (TYP) (BY CANOPY MANUFACTURER) III II II II II TOP FOUNDATION PIER ELEV. 724.00' " BOTTOM OF FOUNDATION PIER ELEV. 722.67' (MAX TYP) III IIII SLOPE TOP FOR I I II POSITIVE IIII WATER RUNOFF II 6" SCH 40 STEEL PIPE o FILLED WITH CONCRETE I AND PAINTED (SEE NOTE) LJ LJ 1/2" SLOPE ON TOP SURFACE OF CONCRETE ENCASEMENT .. ' 'EARTH a a. PAVEMENT OR d d' a ` d . O ' CLASS "B" CONCRETE d ENCASEMENT n < , d d.. 6 "� 6" NOTE, FINISH WITH ONE COAT OF EPDXY PRIMER AND 2 COATS OF ALL WEATHER ENAMEL, COLOR SAFETY YELLOW. C/ T Y OF GREENSBORO STD. NO. REV. BOLLARD (STATIONARY) 121 06/15 1 M 1- 00 N ZZ 0 EXIST FLOOR EL 742.00' SLUDGE CONVEYOR (SEE M—SHEETS) �4 4'-6" EXIST EXTER OR BUILCiNG 'v' L ROOF COUNTER FLASHING TO BRICK WALL WITH PRE—FINISHED METAL COPING (MIN 16 GA) TO MATCH CANOPY STRUCTURE (BY CANOPY MANUFACTURER) CONVEYOR SUPPORT LOCATION AND LOAD TO BE DETERMINED BY CONVEYOR MANUFACTURER WALL CLOSURE (SEE DETAIL SHEET S-5) EXIST FLOOR EL 724.00' 1 . 4 .�- a 1 Q --- Q 6 4 6 ( O do A a EXIST F00 ER EL 720.50' LJ CANOPY SECTION 12'-0" BOLLARD (BEYOND) (SEE DETAIL SHEET THIS SHEET) COLUMN ANCHOR BOLTS (BY CANOPY MANUFACTURER) PRE—ENGINEERED METAL CANOPY CONVEYOR CHUTE COLUMN (BY CANOPY MANUFACTURER) EX',ST CONCRETE PAVEMENT LEV. 723.5'± BOTTOM OF FOUNDATION NO LOWER THAN ELEV. 719.67' (SEE NOTE 1) CANOPY FOUNDATION (BY CANOPY MANUFACTURER) 36" HIGH ALUMINUM FASCIA PANEL BOTTOM CANOPY EL 748.00' w U Z Q o� la W N U DOWNSPOUT (TYP) (BY CANOPY MANUFACTURER) III II II II II TOP FOUNDATION PIER ELEV. 724.00' " BOTTOM OF FOUNDATION PIER ELEV. 722.67' (MAX TYP) III IIII I I II IIII II �< LJ LJ NOTE: 1. BOTTOM ELEVATION OF SOUTH CANOPY COLUMN FOUNDATIONS SHALL BE NO LOWER THAN ELEV. 719.67. LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 know what's below. Call before you dig. - COG Water GDOT Traff COG/GUI COG Water Tanks/Tr GDOT Storm SEALS uiuuriiii CARq''%, Essl \ e S E /sq A!N g0�� SEAL NOT VALID UNLESS SIGNED AND DATED CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 12/01/20181 PERMIT N0. I DATE I ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: S-6 DESIGNED BY: L. BOWE DRAWN BY: W. LEAK CHECKED BY: R. KOLODZAIKE SHEET TITLE STRUCTURAL SHB—CANOPY SECTION AS SHOWN CONTRACT SHEET 26 of 48 SHEET S-7 OF 7 INSTRUMENT IDENTIFICATION LEGEND BASE INSTRUMENTATION SYMBOLS INSTRUMENT, FIELD MOUNTED. SEE THIS SHEET FOR DETAILS OF INSTRUMENT TAGGING SYSTEM. FULL TAG NUMBER SHOULD BE INCLUDED ON INSTRUMENT INDEX. POWER SUPPLY REQUIRED LOCALLY WHERE SHOWN. FIRST LETTER SUCCEEDING LETTERS AS PART OF ONE UNIIT. MEASURED OR INSTRUMENT, PANEL FACE MOUNTED READOUT OR OUTPUT AE m E INITIATING MODIFIER PASSIVE FUNCTION MODIFIER o VARIABLE, ALARM SWITCHES AT PRESET VALUE. FUNCTION H2S-HYDROGEN SULFIDE EQUIPMENT NUMBER (Y) ONLY WHEN A ANALYSIS NECESSARY. SEE BELOW FOR FUNCTIONS ALARM McOH-METHANOL (X). B BURNER FLAME DIFFERENCE NOT USED NOT USED NOT USED C CONDUCTIVITY HIGH SELECTOR I� CONTROL CLOSED °r I/P CURRENT/PNEUMATIC CONVERTER O/S/C 1/1 CURRENT/CURRENT CONVERTER (REPEATER) D DENSITY (MASS) OR DIFFERENTIAL o AV AVERAGE C3 SPECIFIC GRAVITY RATIO SCR SILICON CRYSTAL RECTIFIER cn E VOLTAGE EMF PRIMARY ELEMENT START -STOP WITH LOCKOUT G IL F FLOW RATE RATIO (FRACTION) W -WHITE (POWER ON) G INTRUSION (ALARM CONDITION) GLASS GAGE F -FLASHES ON ELECTRIC OR MECHANICAL MALFUNCTION O UNCALIBRATED 1 = NOTE H HAND MANUALLY HIGH INITIA ED I C RRENT INDICATE ELECTRICAL J POWER SCAN K TIME OR TIME CONTROL STATION SCHEDULE L LEVEL LIGHT PILOT LOW M MOISTURE OR MIDDLE OR INTER - HUMIDITY MEDIATE N SEQUENCE, NOT USED NOT USED NOT USED STRATEGY 0 NOT USED ORIFICE RESTRICTION OPEN P PRESSURE OR POINT TEST PULSE VACUUM CONN CTION Q QUANTITY INTEGRATE OR TOTALIZE R RADIOACTIVITY RECORD OR PRINT S SPEED, FREQUENCY SAFETY SWITCH T TEMPERATURE TRANSMIT U MULTIVARIABLE MULTIFUNCTION MULTIFUNCTION MULTIFUNCTION V VIBRATION VALVE DAMPER OR W WEIGHT OR FORCE WELL X UNCLASSIFIED X AXIS UNCLASSIFIED UNCLASSIFIED UNCLASSIFIED Y EVENT Y AXIS RELAY OR COMPUTE STATUS Z POSITION DRIVE, ACTUATE OR UNCLASSIFIED FINA CONTROL ELEMENT BASE INSTRUMENTATION SYMBOLS INSTRUMENT, FIELD MOUNTED. SEE THIS SHEET FOR DETAILS OF INSTRUMENT TAGGING SYSTEM. FULL TAG NUMBER SHOULD BE INCLUDED ON INSTRUMENT INDEX. POWER SUPPLY REQUIRED LOCALLY WHERE SHOWN. IAS FR & AR ARE TWO FUNCTIONS r FR AR AS PART OF ONE UNIIT. FIR INSTRUMENT, PANEL FACE MOUNTED 3 (FUNCTIONS IN PLC) AE m E X INSTRUMENT, RELAY MOUNTED IN REAR OF PANEL (BROKEN LINE). ACTIVATES X Y AND DEACTIVATES CONTROL AND/OR o i ALARM SWITCHES AT PRESET VALUE. H/O/R H2S-HYDROGEN SULFIDE EQUIPMENT NUMBER (Y) ONLY WHEN o o NECESSARY. SEE BELOW FOR FUNCTIONS L/O/R McOH-METHANOL (X). NaHOCL-SODIUM HYPOCHLORITE 0 DIFFERENCE j NOH -SODIUM HYDROXIDE NH3 -AMMONIA > HIGH SELECTOR I� C LOW SELECTOR °r I/P CURRENT/PNEUMATIC CONVERTER O/S/C 1/1 CURRENT/CURRENT CONVERTER (REPEATER) RS F SUMMATION o AV AVERAGE C3 % RATIO IAS FR & AR ARE TWO FUNCTIONS r FR AR AS PART OF ONE UNIIT. # # r� (CIRCLES TOUCH) 3 (FUNCTIONS IN PLC) AE SYMBOLS (X) FOR ANALYTICAL DEVICES: i # ALKY-ALKALINITY X CH 4 -METHANE 24V C12 -CHLORINE i DO -DISSOLVED OXYGEN H/O/R H2S-HYDROGEN SULFIDE N H3 PO4 -PHOSPHORIC ACID o H2SO4 -SULFURIC ACID L/O/R McOH-METHANOL NaHOCL-SODIUM HYPOCHLORITE cos g No 2S20S -SODIUM METHA-BISULFITE j NOH -SODIUM HYDROXIDE NH3 -AMMONIA j 02 -OXYGEN 0/C ORP-OXYDATION REDUCTION POTENTIAL pH -HYDROGEN ION CONCENTRATION o TURB-TURBIDITY O/S/C OPEN -STOP -CLOSE c 0 RS RESET z RUN-OFF 1 N Sc S SCR SILICON CRYSTAL RECTIFIER cn S/S START -STOP 4 START -STOP WITH LOCKOUT G IL n R --RED (RUN, START, OPEN) W -WHITE (POWER ON) IAS PROGRAMMABLE LOGIC CONTROLLER SUPPLY (PLC) CONTROL BLOCK 120V AC POWER POINT FOR SHARED VIDEO DISPLAY # (FUNCTIONS IN PLC) # POINT FOR SHARED VIDEO DISPLAY (FUNCTIONS IN PLC) WITH LIMITED # ACCESS (BROKEN LINE). # INTERLOCK 24V # - INTERLOCK CONTROL STRATEGY IAS INSTRUMENT AIR SUPPLY GRGRN104.D001 120V AC POWER SUPPLY ESTOP 120V AC UPS POWER UPS F/O/R FORWARD -OFF -REVERSE �480V 480V AC POWER SUPPLY 24V 24V DC POWER SUPPLY A 0 DISCRETE INPUT/OUTPUT V ANALOG INPUT/OUTPUT A;* DIGITAL COMMUNICATION INPUT/OUTPUT: ETHERNET (E), MODBUS (M), HART (H) OR DEVICENET (D) INSTRUMENT TAGGING SYSTEM TBD-- FI - 0234 UNIT PROCESS NUMBER INSTRUMENT IDENTIFICATION LOOP NUMBER INSTRUMENT SYMBOLS FE MAGMETER EQUIPMENT SYMBOLS Is MOTOR VARIABLE FREQUENCY DRIVE CONVEYOR SCREW PROGRESSING CAVITY PUMP CENTRIFUGAL PUMP CALIBRATION CHAMBER MIXER PANEL DEVICE SYMBOLS BHAND SWITCH (MANUAL SELECTOR) L/O/R FUNCTION SUBSCRIPT (LOCATION MAY VARY) Pg PUSHBUTTON ESTOP FUNCTION SUBSCRIPT (LOCATION MAY VARY) ELECTRONIC HORN W STROBE LIGHT A - AMBER W - WHITE R - RED B - BLUE 1 INTERCONNECTING LINES WITH DOT INDICATE ROUTING I OF THE SAME SIGNAL. I �L 1 } INTERCONNECTING LINES IL - -�- - J WITHOUT DOT INDICATE ROUTING OF MORE THAN ONE SIGNAL CR INTERPOSING CONTROL RELAY MISCELLANEOUS ABBREVIATIONS ABBR. ABBREVIATIONS FO FAIL OPEN 0/C OPEN/CLOSE AMB AMBIENT GEN. GENERATOR OF OVERFLOW ATM ATMOSPHERIC HMI HUMAN MACHINE INTERFACE OL OVERLOAD B/0 BY OWNER KW KILOWATTS % PERCENTAGE COMP. COMPRESSOR LCP LOCAL CONTROL PANEL PLC PROGRAMMABLE LOGIC CONTROLLER CONT'D CONTINUED LCS LOCAL CONTROL STATION POS POSITION DIFF DIFFERENTIAL MALE. MALFUNCTION PRI PRIMARY DWG DRAWING MAX MAXIMUM SEC SECONDARY ELEC ELECTRICAL MCC MOTOR CONTROL CENTER TBD TO BE DETERMINED EQUIP EQUIPMENT MIN MINIMUM TEMP TEMPERATURE EXH EXHAUST MPR MASTER PROTECTION RELAY TYP TYPICAL FC FAIL CLOSE NC NORMALLY CLOSED UPS UNINTERRUPTIBLE POWER SUPPLY FCE FIBER COMMUNICATION ENCLOSURE NO NORMALLY OPEN VFD VARIABLE FREQUENCY DRIVE FLR FLOOR NTS NOT TO SCALE WC WATER COLUMN GENERAL NOTES 1. COORDINATE WORK WITH OTHER DRAWINGS AND DISCIPLINES. 2. THE SYMBOLS SHOWN ON THIS SHEET ARE STANDARD DESIGNATIONS. NOT ALL SYMBOLS ARE APPLICABLE TO THE INCLUDED DIAGRAMS AND INSTRUMENT TAGGING SYSTEM. 3. NOT ALL PIPING, FITTINGS, AND TANK DETAILS ARE SHOWN. REFER TO PROCESS DRAWINGS FOR ACTUAL DETAILS. 4. INSTRUMENT IDENTIFICATION AND LOOP NUMBERS APPEAR WITH INSTRUMENT SYMBOL. 5. TAG NUMBER DOES NOT CHANGE IF SIGNAL IS BROUGHT TO ANOTHER CONTRACT AREA. 6. FINAL ALPHA CHARACTER IN TAG (E.G. FI -101A) INDICATES DUPLICATE DEVICE EXISTS. FI -101B MAY BE IN A PANEL. LINE TYPES —o—a—� SOFTWARE LINK, SYSTEM FUNCTION CONNECTION OR COMMUNICATION LINK MAIN PROCESS LINE AUXILIARY SYSTEMS EQUIPMENT PACKAGE LIMIT PNEUMATIC - - - - - - - - ELECTRIC (ELECTRONIC) SIGNAL FUTURE EXISTING DRAWING CONTINUATION LEGEND PROCESS LINE NOT WITHIN THE BOUNDARY OF THIS SET OF DRAWINGS PROCESS DESCRIPTION INSTRUMENT SIGNAL LINES (ON/OFF PAGE): SIGNAL NAME CONN DRAWING NUMBER INSTRUMENT SIGNAL LINE NOT WITHIN THE BOUNDARY OF THIS SET OF DRAWINGS SIGNAL NAME CONN: CONNECTION NUMBER SEE SYMBOLS AND LEGEND 2 FOR PROCESSS MEDIUM DESIGNATIONS A/skRCt4DIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's be[OW. Call before you dig. City of GT6"I;�oro Und- 4 oround Locates Infrtx��ar�Rquests COG Water Ro dGrces,Dept -336-373-2033 GOOT Traffic SA I ` 36-373-2606 COG/Guilford,Cp T\lp�p %,�36-373-2084 COG Water, Supple, r <.<'6-373-5855 Tanks/Treat ?, GOOT Storm:6-373-2569 SEALS CAr�rri i H 1, SEA}�� 236 EN S ��rrllllll►�� � � C — L d CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 2/01/20181 PERMIT NO. DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FUNCTION SUBSCRIPTS FOR HAND GRGRN104.D001 SWITCH AND PUSHBUTTON CONTROLS: 1-1 ESTOP E -STOP DRAWN BY: F/O/R FORWARD -OFF -REVERSE S. STERN F/O/JR FORWARD -OFF -JOG REVERSE H/O/A HAND -OFF -AUTO H/O/R HAND -OFF -REMOTE H/O/SBY NAND -OFF -STANDBY L/O/R LOCAL -OFF -REMOTE L/R LOCAL -REMOTE M/A MANUAL -AUTO M/O/A MANUAL -OFF -AUTO 0/C OPEN -CLOSE 0/0 ON-OFF O/S/C OPEN -STOP -CLOSE RS RESET R/Q RUN-OFF Sc SPEED CONTROL POTENTIOMETER SCR SILICON CRYSTAL RECTIFIER S/S START -STOP S/SLO START -STOP WITH LOCKOUT G IL INDICATING LIGHT UNIT G -GREEN (OFF, STOP, CLOSED) R --RED (RUN, START, OPEN) W -WHITE (POWER ON) A -AMBER (ALARM CONDITION) F -FLASHES ON ELECTRIC OR MECHANICAL MALFUNCTION O INTERLOCK 1 = NOTE NUMBER ELECTRONIC HORN W STROBE LIGHT A - AMBER W - WHITE R - RED B - BLUE 1 INTERCONNECTING LINES WITH DOT INDICATE ROUTING I OF THE SAME SIGNAL. I �L 1 } INTERCONNECTING LINES IL - -�- - J WITHOUT DOT INDICATE ROUTING OF MORE THAN ONE SIGNAL CR INTERPOSING CONTROL RELAY MISCELLANEOUS ABBREVIATIONS ABBR. ABBREVIATIONS FO FAIL OPEN 0/C OPEN/CLOSE AMB AMBIENT GEN. GENERATOR OF OVERFLOW ATM ATMOSPHERIC HMI HUMAN MACHINE INTERFACE OL OVERLOAD B/0 BY OWNER KW KILOWATTS % PERCENTAGE COMP. COMPRESSOR LCP LOCAL CONTROL PANEL PLC PROGRAMMABLE LOGIC CONTROLLER CONT'D CONTINUED LCS LOCAL CONTROL STATION POS POSITION DIFF DIFFERENTIAL MALE. MALFUNCTION PRI PRIMARY DWG DRAWING MAX MAXIMUM SEC SECONDARY ELEC ELECTRICAL MCC MOTOR CONTROL CENTER TBD TO BE DETERMINED EQUIP EQUIPMENT MIN MINIMUM TEMP TEMPERATURE EXH EXHAUST MPR MASTER PROTECTION RELAY TYP TYPICAL FC FAIL CLOSE NC NORMALLY CLOSED UPS UNINTERRUPTIBLE POWER SUPPLY FCE FIBER COMMUNICATION ENCLOSURE NO NORMALLY OPEN VFD VARIABLE FREQUENCY DRIVE FLR FLOOR NTS NOT TO SCALE WC WATER COLUMN GENERAL NOTES 1. COORDINATE WORK WITH OTHER DRAWINGS AND DISCIPLINES. 2. THE SYMBOLS SHOWN ON THIS SHEET ARE STANDARD DESIGNATIONS. NOT ALL SYMBOLS ARE APPLICABLE TO THE INCLUDED DIAGRAMS AND INSTRUMENT TAGGING SYSTEM. 3. NOT ALL PIPING, FITTINGS, AND TANK DETAILS ARE SHOWN. REFER TO PROCESS DRAWINGS FOR ACTUAL DETAILS. 4. INSTRUMENT IDENTIFICATION AND LOOP NUMBERS APPEAR WITH INSTRUMENT SYMBOL. 5. TAG NUMBER DOES NOT CHANGE IF SIGNAL IS BROUGHT TO ANOTHER CONTRACT AREA. 6. FINAL ALPHA CHARACTER IN TAG (E.G. FI -101A) INDICATES DUPLICATE DEVICE EXISTS. FI -101B MAY BE IN A PANEL. LINE TYPES —o—a—� SOFTWARE LINK, SYSTEM FUNCTION CONNECTION OR COMMUNICATION LINK MAIN PROCESS LINE AUXILIARY SYSTEMS EQUIPMENT PACKAGE LIMIT PNEUMATIC - - - - - - - - ELECTRIC (ELECTRONIC) SIGNAL FUTURE EXISTING DRAWING CONTINUATION LEGEND PROCESS LINE NOT WITHIN THE BOUNDARY OF THIS SET OF DRAWINGS PROCESS DESCRIPTION INSTRUMENT SIGNAL LINES (ON/OFF PAGE): SIGNAL NAME CONN DRAWING NUMBER INSTRUMENT SIGNAL LINE NOT WITHIN THE BOUNDARY OF THIS SET OF DRAWINGS SIGNAL NAME CONN: CONNECTION NUMBER SEE SYMBOLS AND LEGEND 2 FOR PROCESSS MEDIUM DESIGNATIONS A/skRCt4DIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's be[OW. Call before you dig. City of GT6"I;�oro Und- 4 oround Locates Infrtx��ar�Rquests COG Water Ro dGrces,Dept -336-373-2033 GOOT Traffic SA I ` 36-373-2606 COG/Guilford,Cp T\lp�p %,�36-373-2084 COG Water, Supple, r <.<'6-373-5855 Tanks/Treat ?, GOOT Storm:6-373-2569 SEALS CAr�rri i H 1, SEA}�� 236 EN S ��rrllllll►�� � � C — L d CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 2/01/20181 PERMIT NO. DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.D001 FILE NAME: 1-1 DESIGNED BY: A. TAVERAS DRAWN BY: A. TAVERAS CHECKED BY: S. STERN SHEET TITLE INSTRUMENTATION SYMBOLS AND LEGEND I SCALE: NONE CONTRACT SHEET 27 OF 4$ SHEET 1— 1 OF 8 m N 5 to In 4 ZZ 0 d` b w— C3 0 a 3 Q ,,j i z i T i 0 12 g a a fi 0 0 z I ch F in J pa.. 0 L: LINE IDENTIFICATION EQUIPMENTNALVE IDENTIFICATION VALVE SYMBOL & DESIGNATION ACTUATOR TYPE PIPING SYMBOLS LOCATION ABBREVIATIONS 12"—RWW—STL P — 0201 NORMALLY OPEN BALL VALVE (BV) M SHB SOLIDS HANDLING BUILDING ELECTRIC MOTOR ACTUATOR (E) DIAPHRAGM SEAL PIPE SIZE EQUIPMENT/VALVE NORMALLY CLOSED BALL VALVE (BV) X Y WITH ISOLATION VALVE PROCESS MEDIUM DESIGNATION BALL CHECK VALVE (BC) PIPE MATERIAL LOOP NUMBER BUTTERFLY VALVE (BFV) TX Y PNEUMATIC ACTUATOR (P) EXPANSION TANK BUTTERFLY VALVE (DIGESTER GAS SERVICE) — (WITH RUPTURE DISC) OPEN/CLOSE APPLICATIONS (BD) BUTTERFLY VALVE (AIR SERVICE) — OPEN/CLOSE APPLICATIONS (BR) HYDRAULIC ACTUATOR (H) 0 HIGH PERFORMANCE BUTTERFLY VALVES (DIGESTER X Y PULSATION DAMPENER GAS SERVICE) — MODULATING APPLICATiONS (HD) HIGH PERFORMANCE BUTTERFLY VALVES (AIR SERVICE) �- MODULATING APPLICATIONS (HR) PROCESS MEDIUM EQUIPMENT DESIGNATIONS WHERE "X" DESIGNATES OPERATION TYPE AND CHECK VALVE (CH) "Y" DESIGNATES CONTROL STATION TYPE FLEXIBLE HOSE/TUBING CHECK VALVES (DIGESTER GAS SERVICE) — (CD) AA AQUA AMMONIA CHECK VALVES (AIR SERVICE) — (CR) AIR AIR FLAW AC AIR COMPRESSOR BWW BACKWASH WASTE AHU AIR HANDLING UNIT AUTOMATIC ELECTRIC CHECK VALVES (CT) —E FLUSHING CONNECTION SWING CHECK VALVE SC CA COMPRESSED AIR B BLOWER ( ) OPERATION TYPE CAP COAGULANT AID POLYMER BFP BELT FILTER PRESS SWING FLAP CHECK VALVE (SF) CAT CALCIUM THIOSULFATE BPV BACK PRESSURE VALVE RUBBER CHECK VALVE (RC) CFE COMBINED FILTER EFFLUENT CNV CONVEYOR OC OPEN/CLOSE CALIBRATION COLUMN CS CAUSTIC SODA (SODIUM HYDROXIDE) EG ENGINE GENERATOR PLUG VALVE MD MODULATING CWR COOLING WATER, RETURN EQ EQUALIZATION CWS COOLING WATER, SUPPLY F FILTER DAF DISSOLVED AIR FLOTATION FLC FLOCCULATOR DR DRAIN G GATE DW DILUTION WATER M MOTOR GLOBE VALVE (GL)SW SEAL WATER DWV DRAIN WASTE AND VENT MBS MECHANICAL BAR SCREEN FAP FILTER AID POLYMER MXR MIXER FAS FILTER AIR SCOUR MCC MOTOR CONTROL CENTER GATE VALVE (GV) FBP FILTER BACKWASH POLYMER P PUMP METAL SEATED GATE VALVES — SOLID WEDGE FE FILTER EFFLUENT PD PULSATION DAMPENER AND DOUBLE DISC TYPE (GM) Y DRAIN FI FILTER INFLUENT PRV PRESSURE RELIEF VALVE RESILIENT—SEATED GATE VALVES (GR) FL FLUORIDE PS PLATE SETTLER KNIFE GATE VALVE (KV) FLW FLUSHING WATER RP ROTARY PRESS FSW FIRE SERVICE WATER MAIN SCR SCREEN FTW FILTER TO WASTE SD STORM DRAIN REDUCER FW FINISHED WATER ST STRAINER AUTOMATIC PRESSURE REDUCING VALVES (PR) FWT FINISHED WATER TRANSMISSION STP SUBMERSIBLE TURBINE PUMP FWTM FINISHED WATER TRANSMISSION MAIN T TANK GAC GRANULAR ACTIVATED CARBON UV UV UNIT ANNULAR ISOLATER GOX GASEOUS OXYGEN VFD VARIABLE FREQUENCY DRIVE GW GROUNDWATER WSH WASHER/COMPACTOR AUTOMATIC PRESSURE SUSTAINING VALVES (PS) HDPE HIGH ENSITY POLYETHYLENE �--� �- SPOOL PIECE HP HYDROGEN PEROXIDE HS HIGH SERVICE HWR HOT WATER RETURN HWS HOT WATER SUPPLY RELIEF VALVE (RV)FLEX{BLE COUPLING IA AIR, INSTRUMENT SUPPLY IFE INDIVIDUAL FILTER EFFLUENT LOX LIQUID OXYGEN NB NITROGEN BOOST SLUICE GATE (SL) NPW NON—POTABLE WATER 02 OXYGEN GAS SLIDE GATE ( SG OF OVERFLOW ) SLIDE PLATE OG OZONE OFF—GAS (SP) OR ORTHOPHOSPHATE OZ OZONE SOLENOID VALVE (SV) PA PROCESS AIR (SOLENOID SHOWN WITH BALL VALVE. VALVE PAC POWERED ACTIVATED CARBON TYPE MAY VARY.) PACL POLYALUMINUM CHLORIDE POLY POLYMER FO=FAIL OPEN PP POTASSIUM PERMANGANATE FC=FAIL CLOSED PTC POTABLE WATER, COLD PTH POTABLE WATER, HOT PW POTABLE WATER RD ROOF DRAIN REC RECYCLE RW RAW WATER RWI RAW WATER INTAKE RWSS RAW WATER SUPPLY SYSTEM RWT RAW WATER TRANSMISSION RWTM RAW WATER TRANSMISSION MAIN SA SULFURIC ACID SAM SAMPLE SAN SANITARY SEWER SD STORM DRAIN SFTW SOFTENED WATER SHC SODIUM HYPOCHLORITE SL SLUDGE STP SOLIDS THICKENING POLYMER SUPR SUPERNATANT SWE SETTLED WATER EFFLUENT TS THICKENED SLUDGE WW WASTEWATER WWS WASH WATER SUPPLY PIPE MATERIAL CU COPPER DI DUCTILE IRON CPVC CHLORINATED POLYVINYL CHLORIDE FIRM CENTRIFUGALLY CAST FIBERGLASS REINFORCED POLYMER MORTAR HDPE HIGH DENSITY POLYETHYLENE PVC POLYVINYL CHLORIDE STL CARBON STEEL SS STAINLESS STEEL kROXDIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRNE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C--1869 ® c� Know what's below. Call before you dig. CHY of reensbofo<UnC66round Loca#es Infotmcdton/Requests COG Water RetoOrtes J)ept X36-373-2033 GDOT Traffic Signal 36--373-2606 COG/Guilfara")d Telecors _�36-373-2084 COG Water 6-373-5855 Tanks/Tea�neDt GDOT 5torin��iater "." 335-373-2569 SEALS SE 23669 kp GIN : s `,`,��. ENS •,,#m11{ to CMZ��a CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 20'17-014A 1 2/01/2018 PERMIT NO. DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: 1-2 DESIGNED BY: A. TAVERAS DRAWN BY: A. TAVERAS CHECKED BY: S. STERN SHEET TITLE INSTRUMENTATION SYMBOLS AND LEGEND 11 SCALE: NONE CONTRACT SHEET 28 of 48 SHEET 1-2 OF 8 LEGEND: —0—o—o— CAT -6 CABLE (UNLESS OTHERWISE NOTED) OPERATOR WORKSTATION NO. 2 FO FIBER --OPTIC CABLEOPERATOR WORKSTATION NO. 1 OPERATOR WORKSTATION NO. 1 ADMIN BUILDING UPPER CONTROL ROOM ADMIN BUILDING LOWER CONTROL ROOM ADMIN BUILDING UPPER CONTROL ROOM F_ -I I 0-0-0-0-0-0-0—G-0 GENIUS 1/0 BUS ° AREA/LOCATION LIMITS ° oo:po oo ° ° ° O ° F5P OINT HUB 0°1111°°❑°❑°1111 ° ° FOC FO FO FO FO FO FO FO FO FO FO ° o--000-0� FIBER OPTIC UPLINK TO SERVER "HUFFINE" NORTH BUFFALO CREEK FO FO FO FO ° ETHERNET SWITCH 1EILIE1006 ADMINISTRATION El El ❑ D —0-0 --- o ------ o ° o o o p -- G-0 o 0-0-0-0-0-0 0-0-0 BLDG. D Em - OJ PLC -3 PLC -3-L! PLC -3-R1 PLC -3-R2 ° ° oo BLOWER NO. 3-4 BLOWER NO. 1-2 AERATION TANKS AERATION TANKS SERVER "05BORNE" CONTROLS CONTROLS 1-8 9-12 D ° D CAT -5 CABLE 0 0 LO -0-0,-0-0-0-0-0-0-0-0-0-00-0-0-0-0 o oL 0—h& _tk o FO FO FO FO FO — — FO FO FO FO Fo — PLC -11 PLC -11-R1 COMMUNICATIONS PANEL ° 00 ° (MOUNTED NEXT REEDY FORK PUMP REEDY FORK PUMP ❑°1111❑Q❑ STATION LIFT STATION STATION LIFT STATION TO PLC -1 D) ETHERNET swrrcH 1111❑❑❑❑ ETHERNET SWITCH ❑11❑❑°1111 ❑00❑❑❑❑ o D 1 T I ° ° CAT -5 CABLE FO FO 0 ° ° o ° 0 . � o—a o o 0-0-o oo0I J PLC -1 0- II PLC -10-R* PATCH ooao°00000n� EFFLUENT FILTERS EFFLUENT FILTERS acaoao PANEL 04 ETHERNET SwfTCH ❑❑❑❑��❑ ° O ~—O ° FO FO FO I PLC -1-R1 PLC -1 a INFLUENT PUMPING INFLUENT PUMPING STATION STATION r ZZ F8 F8 F8 F8 F8 F8 F8 F8 F8 F8 F8 �8 PLC -17 :5 BACKWASH DRAIN PUMP STATION E — — FO FO FO FO FO FO PLC -2-R2 PLC -2-R1 PLC -2 SLUDGE THICKENING PRIMARY SETTLING GRIT AND PRE -AERATION c PUMP STATION PUMP STATION PUMP STATION a N r 0 E �' OODO °D ---D p°—D °—o--°o°—o FO FO FO - 00 PLC -6-R3 PLC -6-R1 PLC -6-R2 PLC -6 BELT FILTER PRESS MULTIPLE HEARTH INCINERATOR GRIT BELT FILTER PRESSES r CONTROL PANEL (NOTE 3) 9 FO 3 • FO 00 00 NOTES: 1mkRC1m01S 1. FOURNIER PRESS PLC PANEL LEGAL ENTITY: SHALL BE RELOCATED AND ARCADIS G&M OF RENAMED AS ROTARY PRESS NORTH CAROLINA, INC. CONTROL PANEL. MODIFY PANEL AS REQUIRED, INCLUDING NEW ONE CENTERMEW DRIVE, SUITE 208 PLC, RELAYS, TERMINAL BLOCKS, GREENSBORO, NORTH CAROLINA 27407 AND APPURTENANCES, TO TEL: 336-292-2271 FAX: 336-855-5648 INCORPORATE NEW 1/0 SIGNALS WWW.ARCADIS.COM AND CONTROL LOGIC AS SHOWN LICENSE NO. C-1869 AND SPECIFIED. FO FO 2. MODIFY PLC -12 AS REQUIRED TO 0 ACCEPT NEW CAT -6 CABLE FROM ROTARY PRESS CONTROL PANEL o� AND ESTABLISH COMMUNICATION LINK WITH EXISTING SCADA SYSTEM. 3. MODIFY PLC -6-R1 AS REQUIRED Know wha#'s below. TO ACCEPT NEW CAT -6 CABLE Call beforfeyou dig. FROM BELT FILTER PRESS .......................... CONTROL PANEL AND ESTABLISH �... COMMUNICATION LINK WITH Clty of reenslx�ro Underground EXISTING SCADA SYSTEM. �� ���trn�r?lRuests o � - COG Water ResiaU� cos Dept X36-373-2033 4. EXISTING HARDWARE, WIRING, AND GDOT Traffic::Sxgnad x`336-373-2606 CABLE ROUTING SHOWN MAY COG/Guilfort>i Ca Ieleco�rt, �6-373-2084 VARY FROM FIELD CONDITIONS. COG Water 5063373-5855 Tanks/ Tea#�it�e#1t Plns�t BOOT StarF� ,ate>~ 6-373-2569 SEALS -9� 00 GENIUS 1/0 BUS —FO -- -- 00 ETHERNET SWITCH ❑ ❑❑80 FO ! 0 yyyyM PLC -5 PLC -5-R1 PLC -5-R2 PLC -5-R3 o EFFLUENT DISINFECTION EFFLUENT DISINFECTION EFFLUENT DISINFECTION EFFLUENT DISINFECTION o FO L � FO FO 0 PLC -4 PLC -4-R1 RAS PUMPING RAS PUMPING o STATION NO. 1 STATION NO. 2 FO FO ETHERNET SWITCH ❑0011❑❑0 FO FD FO yy ❑❑❑ FO FO 0. 0 PLC -9 *a I° CENTRIFUGES / o I NOTE 1 FO FO FO L. PLC -8 PLC -7 SFONrER PR S� FLUIDIZED BED INCINERATOR CENTRIFUGES o° NO. 1 PLC�PANEI!// o CP9001 �Y`���ia FO 0 SYSTEM N0. 2 000 g oQo FO FO F0 FO -- ooc r �oe FOhT FD FO FO FD FO FD FD FO loeovo 3 o0000000— ne00000000 o000000eoe i SLUDGE CAKE PUMP 102 OIT PLC -16 SLUDGE CAKE PUMP 102 a 0 ME 8 z I N a c� FO FO FO FO FO FO FO FO FO PLC -13 ETHERNET SWITCH 0 PREHEAT BURNER �- FO FO FO FO LL I � .97 100 Li FO FO o 0 Li L- o--0poo FD FO PLC -12-R1 PLC -12 PLC -14 ROTARY PRESSCEMS SYSTEM NO. 2 FLUIDIZED BED INCINERATOR CONTROL PANEL NO 2 (NOTE 1) (NOTE 2) 0 LL 0 Li 0 L_ 0 L.L. 0 Li 0 Li 0 LL. SOLIDS HANDLING BUILDING FOC ° O p � OPERATOR WORKSTATION SOLIDS HANDLING CONTROL ROOM GENIUS 1/0 BUS —0� — — 0 0 CP9002 CP9003 SLUDGE CAKE PUMP PLC-CEMS ° CONTROL PANEL O �•``�0'.-0 ss oo�'�r'•: 7 � V � 5E 2 669 (Pc WEE�'�e=� CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 2/01/2018 PERMIT N0. I DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.D001 FILE NAME: 1-3 DESIGNED BY: A. TAVERAS DRAWN BY: A. TAVERAS CHECKED BY: S. STERN SHEET TITLE INSTRUMENTATION N ETWO R K ARCHITECTURE 000 000 FO FO FO FO FO oao eos a undo I Oti0000cooq PLC -15 SLUDGE CAKE PUMP 101 OIT SLUDGE CAKE PUMP 101 SCALE: NONE CONTRACT SHEET 29 OF 48 SHEET 1-3 OF 8 5 T N ui 0 M 4z C 0 c 0 a N r 0 E I- 00 ao 0 r r� m i V) 0 12 g a 0. 0 ME 8 i 4 W a c� Q a U � LJ CD CD z� F-: Cn x w OPEN/ CLOSE OPEN CMD CLOSED ZIL p ZIL xxxx xxxx xxxx oo a OPEN/ POLYMER CLOSE HIGH HIGH FLOW DUTY DUTY VFD NOT IN RUN SPEED SPEED DISCHARGE DUTY VFD NOT IN RUN SPEED SPEED DISCHARGE OPEN CMD CLOSED SP 1 2 STATUS RUN FAIL AUTO FAULT CMD CMD IND. ESTOP PRESSURE STATUS RUN FAIL AUTO FAULT CMD CMD IND. ESTOP PRESSURE ZIL HS ZIL FIC HS ZIL YIL UA YIL UA HS FPAH Z1L YIL UA YIL UA HS 5C SI UA PAH XXXX XXXX XXXX 925 925 92O 920A 920 9208 9208 920 92Q 920 920C 920 930 930A 930A 9308 9308 930 930 930 930C 930 o 0 0 0 ao o-ooa o---o-o-ao-o---a-o-o-o-o-o 0 0 0nRAWIAI!'' I_7 (POLY FLOW) 0 DRAWING 1-7 (ESTOP) 0-0-1 1 2 3 4 POLYMER DAY TANK NO.1 VALVE FROM ASH POLYMER PUMP NO.1&2 CALIBRATION CHAMBER - POLYMER DAY TANK NO.1 POLYMER DAY TANK NO.2 5 6 7 8 POLYMER DAY TANK NO.2 VALVE EXISTING COMMON VENT :T — *H NC 4" -POLY --PVC NOTES: 1. ALL MONITORING AND CONTROL SIGNALS AVAILABLE IN THE ROTARY PRESS CONTROL PANEL SHALL BE AVAILABLE FOR DISPLAY AT THE SCADA SYSTEM. SEE SPECIFICATIONS FOR DETAILS. * ASTERISK (*) DENOTES INSTRUMENTS PROVIDED BY PUMP VENDOR UNDER SECTION 43 21 36. INTERLOCK NOTES: 1O ON E -STOP, PUMP SHALL NOT RUN. MANUAL RESET SHALL BE REQUIRED PRIOR TO RESTART. zO ON HIGH DISCHARGE PRESSURE, PUMP SHALL NOT RUN. MANUAL RESET SHALL BE REQUIRED PRIOR TO RESTART. U CL I } J O a a NO m 0-0 0-0 0-0 0-00 a 0 a—° 0-0-0-0-0-0-0-0-0-0-0-0-0 0 0-0-0 0 0`0-0—^-0-0—o 0—o 0-0 —o—o o—o 0 O a 0 a—° 0 0 0-00 —a— —° 0 0 0-0 0-0 0 0 0-0-0-0-0— y 00 —0-- —0 1 2 3 4 47y4 ZSO m (ZSC 5 6 7 8 4�--V4 ZSO I M I i ZSC TO POLYMER DAY TANK 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 5 POLYMER PUMP N0.1 POLYMER PUMP NO.2 ROTARY PRESS POLYMER SYSTEM 9 10 11 12 13 14 15 16 17 1� 1� 1� 1� 7 T t 1� Z� L .1. —1— L -1 —I_LJ VFD H/O/A RESET RUN FAULT RUNTIME V KI F ° S PB IL IL 920 VFD KEYPAD INTERFACE ! 1.5„x1 „ ROTARY PRESS POLYMER PUMP NO.1 18 19 20 21 22 23 24 25 26 1� �, 1� 1� 7 T t Z� Z� L-i—I—L-1L-1—I_LJ VFD H/O/A RESET RUN FAULT RUNTIME V KI F a HS PB IL IL g3O D VFD KEYPAD INTERFACE TO POLYMER DAY TANK I I * 1 — PB ES 03pol TOP 1.5" -POLY -PVC P- 0 ROTARY PRESS POLYMER PUMP NO.2 1 5„x1 „ RFP POLYMER PUMP NO.2 LOCAL CONTROL STATION (BY PUMP VENDOR) ------------ 2 I I I 1 1.5" CAP PI * PSH 920B 920 NC 1 "-POLY-PVC 1.5"--POLY-PVC I _ 1 "x1.5" RFP POLYMER PUMP NO.2 LOCAL CONTROL STATION (BY PUMP VENDOR) ------------- 2 I I I" -POLY -PVC I PI* PSH * 1.5" CAP 930B 930 I 1.5"---POLY-PVC NC 1"x1.5" HeH� NC 26 TO POLYMER DAY TANK TO ASH POLYMER PUMP NO.1 TO ASH POLYMER PUMP No.2 TO CENTRIFUGE POLYMER FEED PUMPS nA/AkRONDIS ¢ 0 LEGAL ENTITY: ARCADIS G&M OF z NORTH CAROLINA, INC. F- 0 ONE CENTERVIEW DRIVE, SUITE 208 x GREENSBORO, NORTH CAROLINA 27407 TEL: 336--292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know whars below. Call before you dig. �\\� d\ City Of) o, nsbgTQ Unerground i_ocoes Infolrii'ir�crtj{(2uesFs COG Water Res aurcesA3ept,-336-373-2033 GOOT Traffic: 5ig a�= 36-373-2606 COG/Guilfgrd:\Gq T.elleCp95-373-2084 COG Water SU' Ppy. 16•-373-5855 Tanks/Trea�phi j? GDOT Storm Watfpr' .r 336-373-25fi9 SEALS ���t,r<ui rl>lirr�� oF's Sro'• �4J,'. SEA 6 = � • ti N S s' / G CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014,A 1 12/01/20181 PERMIT f I N0. I DATE I ISSUED FOR I BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: 1-6 DESIGNED BY: A. TAVERAS DRAWN BY: A. TAVERAS CHECKED BY: S. STERN SHEET TITLE INSTRUMENTATION SHB — POLYMER PUMPS SCALE: NONE CONTRACT SHEET 32 OF 48 SHEET 1-6 OF 8 Q 0 Q U cn W 0 z} pv) V) X W POLYMER SLUDGE INLET WATER VFD NOT IN SPEED SPEED RUN CLOSE OPEN ESTOP FLOW FLOW PRESS PRESENT RUN FAULT AUTO CMD IND. CMD CMD CLOSED OPEN CMD CLOSED OPEN UA FI FI PI PAH YIL UA YILSC SI HS HS ZIL ZfL H5 ZIL ZlL 970 9408 940 940 940 940 940A 9408 940 9*0 940 945 945A 9458 k!P 946 946E 0 a-0 00 0 0 T RAWING 1-5 (UA -970) --..o0—o0—a RAWING 1-6 (UA -970) 0-0-0-0 ESTOPRESET P8 PB 970 T T 9708 A B C EXISTING INSTRUMENT AIR O 0 0 0-0-0 o DRAWING 1-5 (FI -940A) p -o a—o o—p o-0 0-0-0-0-0-0-0 0 0-0 0 0-0 DRAWING I-6 {FI -9408) ° O -O p -O 0 0 0--0-0-0- 000 OO -O OPEN CMD LOW AIR VFD NOT IN SPEED SPEED RUN AIR VFD NOT IN SPEED SPEED RUN ZERO OPEN TORQUE CAKE PRESS RUN FAULT AUTO CMD IND. CMD PRESS RUN FAULT AUTO OL CMD IND. CMD SPEED TORQUE CMD HIGH DETECTED CTRL YIL UA YIL SC SI HS PAL YIL UA YIL p SC SI HS SIL WI HS WAH UA950 950 950 950 955A 955 955B 955 955 955 955 960A 960 960A0 0 0 o o0 __0 _0 0 0 00 0 —o 0-0-0-0-0-0— 0-0-0-0-0-0-0-0-0-0 0-0-0-0-0-0-0-0-0 O O 0 O O O _0-0 O O O- 0--0-0-0--0 D O- O 0 O AL AL AL IF y f IF 11 1 IF 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17 18 19 20 21 FLOCCULATOR FEED VALVE RECIRCULATION WASH VALVE 1 VALVE (TYP FOR WASH VALVES 2-6) ROTARY PRESS SYSTEM 22 25 26 27 24 28 29 30 32 33 34 35 36 37 38 39 40 41 ROTARY PRESS CONVEYOR LOAD CELL 1 (TYP FOR LOAD CELL 2-6) U I a I I PI 970 > > NPW ds � I 0 I 0 a o I FL FROM POLYMER 1.5" -POLY -PVC 2" -POLY -PVC r PUMPS SEE 1-6 E N m I FROM SLUDGE 3" -SL -DIP N PUMPS 0 SEE 1-5 o � I i Z � I i 0 0 IN "—IUpkm-.pV(` 1 I FIT 120V 940B EXISTING FIT2 (1" E&H 50P25) FE 940B 2 I FIT 120V 940 FE 940A EXISTING FIT1 (3" E&H 50W80) EXISTING PIT1 (E&H CEREBAR S) 3 I PIT 940 FLOCCULATOR (NOTE 4) 1"-NPW-PVC 1.5"X1" 4 U I PSH 940 z EXISTING WPS1 I PI r Q5 Q6 Q7 10 11 12 A Tty y L1-i_TLL1_J FLOCCULATOR VFD LOCATED IN F ROTARY PRESS D CONTROL PANEL NC Vcn� W r� � Qo m W _jz af 0 7 Qr-r 0 Z m 0 U PlAkRCADIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336--855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's below. Call before you dig. Cfty of�, rtaensboro Underground Locales InfoErrtv#fgr/0equests COG Water Res qurces.oept,.�96-373-2033 GOOT Traffic. 5igriai " 3fi-373-2606 COG/Guilfor6to.Telecq 36-373-2084 COG Water Supply - T` 336-373-5855 Tanks /TFeatmert Plants'l GOOT Storm Water s38-373-2569 SEALS WASH VALVE, SOLENOID, FLEXIBLE TUBING, PIPING AND APPURTENANCES ASH PRESS REPLACEMENT TO ROTARY PRESS TYPICAL OF 6 13 y T IAS (SEE NOTE 1) 1144 1155 I I ZSC (945 SO 945 `-- FEED VALVE 16 y y IAS (SEE NOTE 1) RECIRCULATION -� � VALVE 3" -SL -PVC RELOCATED ROTARY PRESS EQUIPMENTRECIRCULATION OU ILI (SECTION 43 21 15) (NOTE 6) m NOTES: a 2 1. FIELD INSTALLED 1/4" PLASTIC TUBING FROM ROTARY PRESS JUNCTION BOX TO FLOCCULATOR. cn EXISTING INSTRUMENT PLASTIC TUBING FROM �.�` -�H �HRp : ` e:oFESsi'••.<i c�9•'• AIR TO NPW VALVES. 'SEAL = 19 37 38 39 40 41 n ^ j /� Z� EXISTING ROTARY PRESS 6 �• r '.,(p>'•'•FN TYP OF 6 JUNCTION BOX (JB101 } GINE cLL: PRESS JUNCTION BOX TO LOAD CELLS (NOT SHOWN). AIR RECEIVER Q•25" -IA -TUBING I NOTE 1 CITY OF GREENSBORO TANK AIR FILTER NOTE 2 WATER RESOURCES REGULATOR c NOTE 3 DEPARTMENT T - 0960I TYP OF 6 D E F T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I WASH VALVE, SOLENOID, FLEXIBLE TUBING, PIPING AND APPURTENANCES ASH PRESS REPLACEMENT TO ROTARY PRESS TYPICAL OF 6 13 y T IAS (SEE NOTE 1) 1144 1155 I I ZSC (945 SO 945 `-- FEED VALVE 16 y y IAS (SEE NOTE 1) RECIRCULATION -� � VALVE 3" -SL -PVC RELOCATED ROTARY PRESS EQUIPMENTRECIRCULATION OU ILI (SECTION 43 21 15) (NOTE 6) m NOTES: a 2 1. FIELD INSTALLED 1/4" PLASTIC TUBING FROM ROTARY PRESS JUNCTION BOX TO FLOCCULATOR. cn 2. PRE-INSTALLED 1/4" PLASTIC TUBING FROM ROTARY PRESS JUNCTION BOX TO NPW VALVES. 3. PRE-INSTALLED 1/4' PLASTIC TUBING FROM ROTARY cLL: PRESS JUNCTION BOX TO LOAD CELLS (NOT SHOWN). m W 4. SLUDGE SAMPLER, AIR BLEEDER, AND ASSOCIATED PIPING AND VALVE NOT SHOWN. 5. EXISTING ROTARY PRESS CONTROL PANEL TO BE RELOCATED. MODIFY PANEL AS REQUIRED TO MEET THE FUNCTIONAL REQUIREMENTS AS SHOWN AND SPECIFIED. 6. EXISTING CONDITIONS MAY VARY FROM ARRANGEMENT SHOWN. SEE SPECIFICATIONS FOR DETAILS. 7, ALL MONITORING AND CONTROL SIGNALS AVAILABLE IN THE ROTARY PRESS CONTROL PANEL SHALL BE AVAILABLE FOR DISPLAY AT THE SCADA SYSTEM. CONFIGURATION OF EXISTING SCADA SYSTEM BY OTHERS. 8. PROVIDE NEW INSTRUMENT AND EQUIPMENT TAGS ENGRAVED WITH LOOP NUMBERS SHOWN FOR ALL RELOCATED HARDWARE. y D 2017 -014A S _ IAS (SEE NOTE 2) NC 20 21 22 25 26 27 24 B 1 2012018 PERMIT � � WASH VALVE 1 NO. DATE ISSUED FOR BY LL.1_LTL_L COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. F 0 ROTARY PRESS VFD LOCATED IN ROTARY DATE: FEBRUARY 2018 Y--SL-SS I PRESS CONTROL PANEL I I E PROJECT NO.: GRGRN104.D001 FILE NAME: 1--7 T EXISTING VISHAY MODEL 363 (TYP OF 6) DESIGNED BY: A. TAVERAS C 28 29 30 31 33 34 35 36 950 DRAWN BY: A. TAVERAS y I I I QT t y EXISTING CARLO GAVAZZI CHECKED BY: S. STERN I I I II I F CA18 (TYP OF 6) L _ J —L L 1 —L L J 36 SHEET TITLE CONVEYOR VFD LOCATED Q IN ROTARY PRESS � I EXISTING RD1 INSTRUMENTATION ® CONTROL PANEL ZS (SIEMENS) 6"-FILT-PVC O D 950A SS SHB _ ROTARY PRESS hm ROTARY PRESS HORIZONTAL SCREW — — — — — CONVEYOR — 14" CENTRATE i SCALE: NONE CONTRACT SHEET 33 OF 48 SHEET 1---7 OF 8 9 M 3 v I i z z i 0 0 g o= IL 0 0 ME 8 z I 4 a 0 SIGNAL CABLE TO REMOTE TRANSMITTER Is LEGAL ENTITY: JUNCTION BOX OR ARCADIS G&M OF INTEGRAL TRANSMITTER NORTH CAROLINA, INC. FACTORY DRILLED ONE CENTERVIEW DRIVE, E, SUITE 20 METER FLANGES GREENSBORO, NORTH CAROLINA 27407 08 AND TAPPED FOR TEL: 336-292-2271 BONDING WIRES 9 AWG GRN/YEL FAX: 336-855-5648 BONDING WIRE WWW.ARCADIS.COM LICENSE NO. C-1869 PROCESS LINE PRESSURE GAUGE OR SWITCH ® c> UNION (TYP.) Know whafs beloW. FLUSHING CONNECTION Call before you dig... PLUG o Clty ofC-�eensboro Und6rground 04ARCAD Locat* Infomncrtton/Requests COG Water Resflorces Dept _336-373-2033 THREADED, WELDED UNION 1-1 /2" GOOT Traffic: Sagnai,'. X36-373-2606 PROCESS LINE BALL VALVE COG/GuiIford3; Q1..Telecom'��36--373-2084 (TYP.) COG Water SU' pgly ! 336-373-5855 NOTES: 1-1/2" FIELD WELD TAP PROCESS PIPE Tanks/TCeatment ::Plan', �``_' GDOT Storm.Water - 6-373-2569 OR DIRECT THREAD TAP � � 1. FLOW METER DETAIL SHOWN SHALL BE USED FOR BOTH 4. GROUND WIRE SHALL BE NO. 12AWG INSULATED. IF ELECTRICALLY NON-CONDUCTIVE AND CONDUCTIVE TYPE LENGTH OF GROUND WIRE IS MORE THAN 6 FEET, SEALS PIPELINES. INSTALL CONDUCTOR IN 3/4" CONDUIT. 00III IAll,# . RO 2. BOND MAGNETIC FLOW METER TO ONE OF THE FOLLOWING 5. SIGNAL CABLE SHALL BE INSTALLED IN CONDUIT. ACCEPTABLE GROUNDS: CONDUIT NOT SHOWN. a. METALLIC WATER PIPE IF BURIED PORTION IS MORE SE L THAN 10 FEET. 6. PROVIDE POWER TO TRANSMITTER. POWER WIRING 23 9_ b. STRUCTURAL STEEL AND CONDUIT NOT SHOWN. 3. REMOTE TRANSMITTER SHALL BE LOCATED IN A SUITABLE .,SFA••..GIN .•,•.. ����. LOCATION AND TRANSMITTER SHALL BE PEDESTAL `S��Z_2_(8- MOUNTED OR WALL MOUNTED AS REQUIRED. CITY OF GREENSBORO MAGNETIC FLOW METER(`2PRESSURE GAUGE OR SWITCH WATER- DEPARTMNT RESOURCES I-08 I�-08 NOT TO SCALE NOT TO SCALE T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A PRESSURE SWITCH PRESSURE GAUGE FLEXIBLE CONDUIT FOR ELECTRICAL CONNECTION ly\ / PRESSURE GAUGE 1 2/01/2018 PERMIT N0. DATE ISSUED FOR BY UNION (TYP) � � I � � COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. GASKET (TYP) LOCK RING GASKET (TYP) LOCK RING DATE: FEBRUARY 2018 PROCESS PIPE PROCESS PIPE PROJECT NO.: GRGRN104.D001 FILE NAME: 1-8 DESIGNED BY: A. TAVERAS DRAWN BY: A. TAVERAS CHECKED BY: S. STERN SHEET TITLE ANNULAR ISOLATOR ANNULAR ISOLATOR INSTRUMENTATION END FLANGE (TYP) END FLANGE (TYP)INSTRUMENT MOUNTING DETAILS NOTES: 1. PRESSURE GAUGE AND SWITCH ASSEMBLY SHALL BE FULLY SUPPORTED. SCALE: NONE 3 PRESSURE GAUGE & SWITCH ASSEMBLY WITH ANNULAR ISOLATOR- ("-4PRESSURE GAUGE WITH ANNULAR ISOLATOR— CONTRACT SHEET OF 1-08 NOT TO SCALE I-08 NOT TO SCALE 34 48 SHEET I—S OF 8 DIAGRAMS: MOTOR STARTER/CONTROLLER ® r�71 j (NON -COMBINATION - COMBINATION - MANUAL) RV RV DENOTES REDUCED VOLTAGE ®® LOCAL CONTROL PANEL WITH CONTROLLERS FURNISHED BY EQUIPMENT VENDOR. POWER ON-OFF FLE40CSH�V AC, 20As l�p ❑ 2 PO, 2SWITCH MS 20A TWO OR THREE POLE MANUAL STARTER, PUSH-BUTTON STATION �- PUSH-BUTTON STATION WITH LOCK -OUT FEATURE 0 SELECTOR SWITCH ® INDICATING LIGHT C5 CONTROL STATION H 0 HAND -OFF -AUTO SELECTOR SWITCH CONTROL STATION A VCS CONTROL STATION FURNISHED BY EQUIPMENT VENDOR DISCONNECT SWITCH - 480V 3POLE UNFUSED OR FUSED F F DENOTES FUSING, ONLY WHERE INDICATED. 60/40 FIRST NUMBER DENOTES SWITCH AMP RATING. SECOND NUMBER DENOTES FUSE SIZE WHEN PROVIDED. VF D VARIABLE FREQUENCY DRIVE - VFD 100 (FRAME SIZE) 2P 30 (TRIP SIZE) THERMAL -MAGNETIC CIRCUIT BREAKER 2P WHEN NOTED DENOTES 2 POLE M M MAIN METERING DEVICE D AC COMBINATION FULL VOLTAGE NON -REVERSING STARTER 7A (CONTINUOUS AMP RATING) MCP (MOTOR CIRCUIT PROTECTOR) MAGNETIC BREAKER MAGNETIC MOTOR STARTER OVERLOAD RELAY AC COMBINATION REDUCED VOLTAGE NON -REVERSING STARTER 7A MCP 1S R AUTO -TRANSFORMER TYPE STARTER 25 I ELECTRONIC REDUCED VOLTAGE RVSS-B SOLID STATE STARTER -RVSS -B DENOTES WITH FULL SPEED BYPASS J TRANSFORMER- SIZE AS NOTED ON THE DRAWINGS �1 I DISCONNECT SWITCH WITH FUSING WHERE NOTED SUBMERSIBLE CABLES BY VENDOR TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR AHF ACTIVE HARMONIC FILTER PLANS: DUPLEX CONVENIENCE RECEPTACLE, 2 POLE, 3 WIRE, 120 VOLTS A.C. 20 AMP RECEPTACLE DESIGNATIONS, 1-2 FIRST NUMBER DENOTES PANEL, SECOND NUMBER DENOTES CIRCUIT NUMBER. GF -DENOTES GROUND FAULT TYPE. SS --DENOTES SURGE SUPPRESSION TYPE GF/WPU WPU-DENOTES GF RECEPTACLE IN WEATHERPROOF WHILE--IN-USE ENCLOSURE SINGLE CONVENIENCE RECEPTACLE, 2 POLE, 3 WIRE; 120 VOLTS AC. 20 AMP UNLESS NOTED OTHERWISE ON DRAWINGS. POWER RECEPTACLE, 2 POLE, 3 WIRE 250 VOLTS A.C. 20 AMP UNLESS NOTED OTHERWISE ON DRAWINGS. POWER RECPT. WITH DISCONNECT -600V, 3 PHASE, 4 WIRE X30 NUMBER DENOTES AMPERE RATING Sa SINGLE POLE SWITCH - LOWER CASE LETTER DENOTES SWITCHING. S2 TWO POLE SWITCH S3 THREE-WAY SWITCH LETTERS AND NUMBERS INDICATE PANEL AND CIRCUIT NUMBER (LP1-2). CROSS LINES INDICATE NUMBER OF CONDUCTORS. HALF HASH MARKS INDICATES NEUTRAL. LP1-2 NUMBER (10) DENOTES WIRE SIZE WHEN NOT #12 AWG. D CONTINUE CONDUIT AND WIRE RUN FROM BOX TO DEVICE IN 10 ROOM OR AREA AS NOTED BY BRANCH CIRCUIT NUMBER. #10 AWG WIRING SHALL BE USED FOR RUNS BETWEEN PANEL AND FIRST LIGHTING FIXTURE OR RECEPTACLE EXCEEDING 50 FEET, UNLESS OTHERWISE NOTED ON DRAWING. INDICATES GROUND CONDUCTOR INDICATES HOMERUN AND CONDUIT TAG C12 EHH ELECTRICAL HANDHOLE Ln TELEPHONE HANDHOLE DC ELECTRIC DOOR CONTROLLER, SEE OPERATOR p 0 PC PHOTOCELL 1-3 FLUORESCENT LIGHTING FIXTURE -- SURFACE OR PENDANT 0 _j PI OROrn JUNCTION BOX; SIZE AS REQUIRED BY N.E.C. SECOND NUMBER DENOTES BRANCH CIRCUIT NUMBER. NTS- LOWER CASE LETTER DENOTES SWITCHED CIRCUIT. AND PSL DENOTES PRESSURE LOW) TERMINAL BOX; SIZE AS REQUIRED BY N.E.C. O @1-2A1-24 SURFACE OR PENDANT MOUNTED. CONNECT BATTERY r ❑T OR OT AND TO ACCOMMODATE ALL TERMINATIONS ON OR PENDANT MOUNTED LIGHTING FIXTURE. ® co DOUBLE POLE DOUBLE THROW TERMINAL BLOCKS. TERMINATIONS TO INCLUDE FLOW SWITCH (FSH DENOTES FLOW SWITCH HIGH EMPTY CONDUIT o AND FSL DENOTES FLOW SWITCH LOW) SPARE WIRING. ZS LIMIT SWITCH \ PRESSURE TRANSMITTER (I DENOTES INDICATING TYPE AND PE S DENOTES PRESSURE ELEMENT) PB PULL BOX; SIZE AS REQUIRED BY N.E.C. LEVEL TRANSMITTER (LE DENOTES LEVEL ELEMENT) PNL FIT FLOW TRANSMITTER (FE DENOTES FLOW ELEMENT) AIT ANALYSIS TRANSMITTER (AE DENOTES ANALYSIS ELEMENT) TIT INTERLOCK WITH KEY CAPTIVE IN LOCK TS 0 HIGH (LOCK FOR RESPECTIVE KEY) AND TSL DENOTES TEMPERATURE SWITCH LOW) LS LEVEL SWITCH (LSH DENOTES LEVEL SWITCH HIGH AND LSL DENOTES LEVEL SWITCH LOW. LE DENOTES LEVEL ELEMENT) L1 INTERLOCK (LOCK FOR RESPECTIVE KEY) V5 0 MOV OR MV MOTORIZED VALVE PT m SV SOLENOID VALVE 2/01/2018 ZC STROKE POSITIONER RECEP RECEPTACLE OT OVER -TEMPERATURE DEVICE NO. GATE ISSUED FOR RVSS T COPYRIGHT: ARCADIS G&M OF O O ELECTRIC MOTOR (NUMBER INDICATES HORSEPOWER). SPARE _jh o SELECTOR SWBD a DATE: FEBRUARY 2018 SWGR SWITCHGEAR TEW � MV MOTORIZED VALVE WITH CONTROLLER BY VENDOR TYPICAL E Y UNLESS OTHERWISE NOTED DESIGNED BY: A. TAVERAS USE UNDERGROUND SERVICE ENTRANCE DRAWN BY: A. TAVERAS CABLE nC WEATHERPROOF PFD WT WINDING TEMPERATURE RELAY N a0 TRANSFORMER PFD DENOTES PULL FUSE o DISCONNECT TYPE 1. THE SYMBOLS � N ISHEET COMPREHENSIVE GUIDE INENDED ORGENERALUSE ON ALL SYMBOLS, LEGEND PROJECTS. AND ABBREVIATIONS o � ARE NECESSARILY USED ON THIS PARTICULAR PROJECT AND SHOULD BE USED FOR Q Q1 600/5 CURRENT TRANSFORMER, RATIO AND QUANTITY DENOTED n a 3 r POTENTIAL TRANSFORMER 3 0 Q � o I � w o o S 800 (FRAME SIZE) DRAWOUT POWER CIRCUIT BREAKER w T 800 (SENSOR RATING) WITH RMS TYPE SOLID STATE TRIP / PROGRAMMER w u (600P) DENOTES PLUG RATING EQ DENOTES ELECTRICALLY i i WHEN LESS THAN OPERATED SENSOR RATING IS o REQUIRED 0 t w 2 in o cn o o Is 800 FIXED MOUNTED POWER OR MOLDED CASE CIRCUIT BREAKER M iT 600 WITH RMS TYPE SOLID STATE TRIP PROGRAMMER. o a CL a (400P) DENOTES PLUG RATING WHEN LESS THAN SENSOR RATING ¢ < ¢ IS REQUIRED < x o U- U- a , o FLOAT SWITCH Ln U U o z z f Ln I In o Q Q rK % �j V) U cn n a U m o cn Q / > af w J Ul � Q Q w Of m L m x 100 (FRAME SIZE) 2P 30 (TRIP SIZE) THERMAL -MAGNETIC CIRCUIT BREAKER 2P WHEN NOTED DENOTES 2 POLE M M MAIN METERING DEVICE D AC COMBINATION FULL VOLTAGE NON -REVERSING STARTER 7A (CONTINUOUS AMP RATING) MCP (MOTOR CIRCUIT PROTECTOR) MAGNETIC BREAKER MAGNETIC MOTOR STARTER OVERLOAD RELAY AC COMBINATION REDUCED VOLTAGE NON -REVERSING STARTER 7A MCP 1S R AUTO -TRANSFORMER TYPE STARTER 25 I ELECTRONIC REDUCED VOLTAGE RVSS-B SOLID STATE STARTER -RVSS -B DENOTES WITH FULL SPEED BYPASS J TRANSFORMER- SIZE AS NOTED ON THE DRAWINGS �1 I DISCONNECT SWITCH WITH FUSING WHERE NOTED SUBMERSIBLE CABLES BY VENDOR TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR AHF ACTIVE HARMONIC FILTER PLANS: DUPLEX CONVENIENCE RECEPTACLE, 2 POLE, 3 WIRE, 120 VOLTS A.C. 20 AMP RECEPTACLE DESIGNATIONS, 1-2 FIRST NUMBER DENOTES PANEL, SECOND NUMBER DENOTES CIRCUIT NUMBER. GF -DENOTES GROUND FAULT TYPE. SS --DENOTES SURGE SUPPRESSION TYPE GF/WPU WPU-DENOTES GF RECEPTACLE IN WEATHERPROOF WHILE--IN-USE ENCLOSURE SINGLE CONVENIENCE RECEPTACLE, 2 POLE, 3 WIRE; 120 VOLTS AC. 20 AMP UNLESS NOTED OTHERWISE ON DRAWINGS. POWER RECEPTACLE, 2 POLE, 3 WIRE 250 VOLTS A.C. 20 AMP UNLESS NOTED OTHERWISE ON DRAWINGS. POWER RECPT. WITH DISCONNECT -600V, 3 PHASE, 4 WIRE X30 NUMBER DENOTES AMPERE RATING Sa SINGLE POLE SWITCH - LOWER CASE LETTER DENOTES SWITCHING. S2 TWO POLE SWITCH S3 THREE-WAY SWITCH LETTERS AND NUMBERS INDICATE PANEL AND CIRCUIT NUMBER (LP1-2). CROSS LINES INDICATE NUMBER OF CONDUCTORS. HALF HASH MARKS INDICATES NEUTRAL. LP1-2 NUMBER (10) DENOTES WIRE SIZE WHEN NOT #12 AWG. D CONTINUE CONDUIT AND WIRE RUN FROM BOX TO DEVICE IN 10 ROOM OR AREA AS NOTED BY BRANCH CIRCUIT NUMBER. #10 AWG WIRING SHALL BE USED FOR RUNS BETWEEN PANEL AND FIRST LIGHTING FIXTURE OR RECEPTACLE EXCEEDING 50 FEET, UNLESS OTHERWISE NOTED ON DRAWING. INDICATES GROUND CONDUCTOR INDICATES HOMERUN AND CONDUIT TAG C12 EHH ELECTRICAL HANDHOLE THH TELEPHONE HANDHOLE DC ELECTRIC DOOR CONTROLLER, SEE OPERATOR p CONNECTION DIAGRAM THIS SHEET PC PHOTOCELL 1-3 FLUORESCENT LIGHTING FIXTURE -- SURFACE OR PENDANT 10 MOUNTED. FIRST NUMERAL DENOTES LIGHTING PANEL (LP1), L� a SECOND NUMBER DENOTES BRANCH CIRCUIT NUMBER. NTS- LOWER CASE LETTER DENOTES SWITCHED CIRCUIT. AND PSL DENOTES PRESSURE LOW) FLUORESCENT LIGHTING FIXTURE WITH BATTERY PACK - O @1-2A1-24 SURFACE OR PENDANT MOUNTED. CONNECT BATTERY SWITCH PACK AHEAD OF SWITCH OCEILING OR PENDANT MOUNTED LIGHTING FIXTURE. ® CEILING OR PENDANT MOUNTED LIGHTING FIXTURE WITH DOUBLE POLE DOUBLE THROW AUXILIARY EMERGENCY LAMP WALL MOUNTED LIGHTING FIXTURE. O POLE OR STANCHION MOUNTED LIGHTING FIXTURE. C�u TWO (2) POLE OR STANCHION MOUNTED LIGHTING FIXTURES G POLE MOUNTED FIXTURE WITH GF RECEPTACLE HEM 2 LAMP SELF CONTAINED DC EMERGENCY LIGHTING UNIT. - - - - - LETTER DENOTES FIXTURE TYPE. CONTROL FIXTURE DESIGNATION SYMBOL. SEE LIGHTING FIXTURE p SCHEDULE FOR DESCRIPTION AND TYPE. ALL FIXTURES OGROUND SHOWN IN A ROOM WITH THIS SYMBOL SHALL BE OF TYPE 150 INDICATED BY LETTER; NUMBER IN SYMBOL INDICATES 10'-0" AFF LAMP WATTAGE AND NUMBER OF LAMPS WHERE MORE THAN - G ONE (UNLESS OTHERWISE NOTED). NUMBER BELOW NTS- SYMBOL INDICATES MOUNTING HEIGHT ABOVE FINISHED AND PSL DENOTES PRESSURE LOW) FLOOR OR AS NOTED. O @1-2A1-24 MOTOR, UNIT HEATER -NUMERAL DENOTES OR LIGHTING PANEL AND BRANCH CIRCUIT SWITCH 1-24 NUMBER. MOTOR SYMBOL SHOWN DASHED HIGH AND dPSL DENOTES PRESSURE SWITCH LOW) DENOTES EQUIPMENT LOCATED ON ROOF. TO THERMOSTAT INDICATES NEW EQUIPMENT/EXPOSED CONDUIT HATCHING DENOTES EQUIPMENT TO BE DEMOLISHED ENCLOSED DENOTES EQUIPMENT TO BE RELOCATED L ... _... J INSTRUMENTS: INDICATES EXISTING EQUIPMENT/CONDUIT - - - - - INDICATES CONCEALED OR UNDERGROUND CONTROL EQUIPMENT/CONDUIT OGROUND ROD OGROUND TEST POINT ■ * GROUND GRID CABLE CONNECTION dilGROUND OTHER THAN 15 - G G #4/0 GROUND CABLE BURIED 2'-6" BELOW NTS- GRADE, UNLESS NOTED OTHERWISE HATCHING DENOTES EQUIPMENT TO BE DEMOLISHED ENCLOSED DENOTES EQUIPMENT TO BE RELOCATED L ... _... J INSTRUMENTS: THERMAL DETECTOR SH INSTRUMENT DEVICE: LETTERS IDENTIFY CONTROL PS 1234 DEVICE FUNCTION, NUMBERS WHERE INDICATED AUDIO/VISUAL ALARM INDICATOR A/V 110 DENOTE LOOP NUMBER CONTROL PANEL, NUMBER A5 NOTED S PRESSURE CONTROLLER OTHER THAN 15 PS PRESSURE SWITCH (PSH DENOTES PRESSURE SWITCH HIGH NTS- LETTER INDICATES COLOR AND PSL DENOTES PRESSURE LOW) CURRENT TRANSFORMER dPSH DIFFERENTIAL PRESSURE SWITCH (dPSH DENOTES PRESSURE SWITCH COG water Supply 35-373-5655 HIGH AND dPSL DENOTES PRESSURE SWITCH LOW) CSH DIAPHRAGM LEAK DETECTOR DOUBLE POLE DOUBLE THROW FS FLOW SWITCH (FSH DENOTES FLOW SWITCH HIGH EMPTY CONDUIT AND FSL DENOTES FLOW SWITCH LOW) ELEVATION ZS LIMIT SWITCH PULL FUSE DISCONNECT PRESSURE TRANSMITTER (I DENOTES INDICATING TYPE AND PE S DENOTES PRESSURE ELEMENT) LIT LEVEL TRANSMITTER (LE DENOTES LEVEL ELEMENT) PNL FIT FLOW TRANSMITTER (FE DENOTES FLOW ELEMENT) AIT ANALYSIS TRANSMITTER (AE DENOTES ANALYSIS ELEMENT) TIT TEMPERATURE TRANSMITTER (TE DENOTES TEMPERATURE ELEMENT) TS TEMPERATURE SWITCH (TSH DENOTES TEMPERATURE SWITCH HIGH AND TSL DENOTES TEMPERATURE SWITCH LOW) LS LEVEL SWITCH (LSH DENOTES LEVEL SWITCH HIGH AND LSL DENOTES LEVEL SWITCH LOW. LE DENOTES LEVEL ELEMENT) MS MOISTURE SWITCH V5 VIBRATION SWITCH (VE INDICATES VIBRATION ELEMENT) MOV OR MV MOTORIZED VALVE PT SV OR SV SOLENOID VALVE 2/01/2018 ZC STROKE POSITIONER RECEP RECEPTACLE SL STROBE LIGHT NO. FIRE ALARM SYSTEM: FACP FIRE ALARM CONTROL PANEL l—N HORN MANUAL PULL STATION SD DUCT MOUNTED SMOKE DETECTOR D OSMOKE DETECTOR SD MULTISENSOR -N/\/\- END OF LINE RESISTOR a FLAME DETECTOR ABBREVIATIONS: POARCADIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHF ACTIVE HARMONIC FILTER , ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BFP BELT FILTER PRESS 3 BKR BREAKER Know What's below. CBV CABLE BY VENDOR, INSTALLED BY Call beforeyou dig. CONTRACTOR CKT THERMAL DETECTOR SH (FIXED AND RATE OF RISE) CONTROL H -HIGH TEMPERATURE NOTO AUDIO/VISUAL ALARM INDICATOR A/V 110 (HORN/STROBE) NUMBER INDICATES CONTROL PANEL, NUMBER A5 NOTED STROBE CANDELA RATING WHEN CPT OTHER THAN 15 R ALARM BEACON NTS- LETTER INDICATES COLOR a FLAME DETECTOR ABBREVIATIONS: POARCADIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHF ACTIVE HARMONIC FILTER , ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BFP BELT FILTER PRESS 3 BKR BREAKER Know What's below. CBV CABLE BY VENDOR, INSTALLED BY Call beforeyou dig. CONTRACTOR CKT CIRCUIT 'N GNTRL CONTROL City of90eensboro unclerground NOTO NORMALLY OPEN, TIME OPEN Locates Irafo�&titpn/ttquests CP -1 CONTROL PANEL, NUMBER A5 NOTED CPT CONTROL POWER TRANSFORMER COG water Aespurces Dept X36-373-2033 NTS- GDOT Traffic S�gr(a3j 36-373-2606 CT CURRENT TRANSFORMER COG/Guilford Co^ elec ( 36-373-2084 DN DOWN COG water Supply 35-373-5655 Tanks/TreatME t :f+1 DPDT DOUBLE POLE DOUBLE THROW GDOT Storm ,water �� �� '� -373-2569 EC EMPTY CONDUIT EL, ELEV ELEVATION SEALS PULL FUSE DISCONNECT EP EXPLOSION PROOF EXIST EXISTING CARO ��•` p� oF�ssio•. �� �'� FDR FEEDER ,;Q '►%y` y FIXT FIXTURE _ 5>=AA FVNR FULL VOLTAGE NON -REVERSING �'{ 36 }Lf� G GALVANIZED GND GROUNDGINe GSAS GAS SYSTEM ALARM STATION',, h N S -s �.�` Z- 2 -Is �rrrrllllyl*+'+ HOA HAND/OFF/AUTO IMMED IMMEDIATE CITY OF GREENSBORO JB OR J JUNCTION BOX, CONDUIT, FITTING AS REQUIRED BY NEC, UNLESS WATER RESOURCES NOTED OTHERWISE DEPARTMENT KCMIL OR MCM THOUSAND CIRCULAR MILS LA LIGHTNING ARRESTOR LCP LOCAL CONTROL PANEL T.Z. OSBORNE WATER LTG LIGHTING RECLAMATION FACILITY MCC MOTOR CONTROL CENTER IMPROVEMENTS MTS MANUAL TRANSFER SWITCH NA NON -AUTOMATIC VOLUME NCTC NORMALLY CLOSED, TIME CLOSE ASH PRESS REPLACEMENT NCTC NORMALLY CLOSED TIME 0 SCALE: NONE CONTRACT SHEET 35 OF 4$ SHEET E-1 OF 14 m PEN NOTC NORMALLY OPEN, TIME CLOSED NOTO NORMALLY OPEN, TIME OPEN 2017-014A NEC NATIONAL ELECTRIC CODE NTS- NOT TO SCALE P/B, PB PULL BOX PFD PULL FUSE DISCONNECT PNL PANEL PFC POWER FACTOR CORRECTION CAPACITORS PT POTENTIAL TRANSFORMER 1 2/01/2018 PERMIT RECEP RECEPTACLE RFP ROTARY FAN PRESS NO. GATE ISSUED FOR RVSS REDUCED VOLTAGE SOLID STATE COPYRIGHT: ARCADIS G&M OF (S) (SH) SHIELDED CABLE SP SPARE 2018 NORTH CAROLINA, INC. SEL SELECTOR SWBD SWITCHBOARD DATE: FEBRUARY 2018 SWGR SWITCHGEAR TEW THERMOCOUPLE EXTENSION WIRE PROJECT NO.: GRGRN104.DO01 TYP TYPICAL FILE NAME: E-1 UON UNLESS OTHERWISE NOTED DESIGNED BY: A. TAVERAS USE UNDERGROUND SERVICE ENTRANCE DRAWN BY: A. TAVERAS CABLE WP WEATHERPROOF CHECKED BY: S. STERN WT WINDING TEMPERATURE RELAY SHEET TITLE XFMR TRANSFORMER ELECTRICAL GENERAL NOTES: 1. THE SYMBOLS AND ABBREVIATIONS LIST ON ABBREVIATIONS, ISHEET COMPREHENSIVE GUIDE INENDED ORGENERALUSE ON ALL SYMBOLS, LEGEND PROJECTS. AND ABBREVIATIONS THEREFORE NOT ALL THE SYMBOLS CONTAINED IN THIS LIST AND NOTES ARE NECESSARILY USED ON THIS PARTICULAR PROJECT AND SHOULD BE USED FOR CLARIFICATION ONLY. SCALE: NONE CONTRACT SHEET 35 OF 4$ SHEET E-1 OF 14 m CL ai E I= 0 N ai 0 0 a� 0 Ln 0 U c� 0 N I W U W J W W i 0 O 0 a a U ui li O O V) C.) z i V) a c) W d U] U) ¢ Of W Q Q Q) cn N. POLYMER FEED ROOM (E-8, E-9) :XISTING JUNCTION BOX FOR kSH�-,;GRINDER AND ASH PUMP :QUIPMENT NCTION BOX PROVIDED VOLUME II SOLIDS HANDLING BUILDING - EL 710.00 SOLIDS HANDLING BUILDING - EL 724.00 SCALE: 1/16" = 1'-0" ° 81 16' 32' A . SLUDGE PRESS ROOM (E-7) SOLIDS HANDLING BUILDING - EL 742.00 SCALE: 1/16" = 1'---0" Vj fA kRMIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRNE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL:- 336--292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's below. Call before you dig. City of;` nsIboro. Unc*Qround LocalesIn#oimrlat� qussU COG Water R466rces,Dept.< 36-373-2033 GDOT Traffic ;Sigitia 1 "� 36-373--2606 COG/Gu i 1 f orO.. Cti To , c � 6-373-2084 , COG Water S'up� jr - I, , 6-373-5555 Tanks/T�eai�leDti ' "' GDOT Storm Watt 6-373-2565 SEALS CA'++•,,,. SEA SEN Syys��.�` CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 2/01/2018 PERMIT NO. DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.D001 FILE !NAME: E-2 DESIGNED BY: A. TAVERAS DRAWN BY: A. SUMNER CHECKED BY: S. STERN SHEET TITLE ELECTRICAL SHB — KEY FLOOR PLAN SCALE: AS SHOWN CONTRACT SHEET 36 OF 48 SHEET E-2 OF 14 c� v LL i In 0 g Ix 0- z z I th cn 4 0 w1^Tr 4 NOTES: 1, REFER TO MECHANICAL PLANS FOR DEMOLITION DETAILS. CABLES TO BE DISCONNECTED DURING RELOCATION OF EQUIPMENT. 2. DISCONNECT CONDUCTORS DURING RELOCATION AND RECONNECT CIRCUITS TO NEW LOCATIONS AS SHOWN ON E-4. SLUDGE PUMP ROOM DEMOLITION PLAN EL 710.00 LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C--1869 Know what's below. Call before you dig, crty COG Water RO GOOT Traffic COG/Gu i l f ora COG Water Sq Tanks/Tea GDOT 5tor,Ie` , es 3-2569 SEALS `, `�<<y►►CA �N RQ'•,, 0� bFSS�o•' �� ti SEA g CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME 1 ASH PRESS REPLACEMENT 2017-014A i 2/01/2018 PERMIT N0. I DATE ISSUED FOR BY COPYRIGHT: ARCADVS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.D001 FILE NAME: E-3 DESIGNED BY: A. TAVERAS DRAWN BY: A. TAVERAS CHECKED BY: S. STERN SHEET TITLE ELECTRICAL SHB — SLUDGE PUMP ROOM DEMOLITION PLAN SCALE: AS SHOWN CONTRACT SHEET 37 OF 48 SHEET E-3 OF 14 00 12 0 LO V 0 '611 RELOCATED EXISTING OPTICAL TYPE SOLIDS AN A'LYZIER____ ' ' AIT NOTE I RELOCATED EXISTING MICROWAVE TYPE SOLIDS ANALYZER ..j. a f E- STOP E 0 r?nTAD\/ FAN DDC -CC! SLUDGE Fumr NO. 1 TO "ROTARYFAN PRESS' SLUD( PUMP NO.1 CP NOTE 2 _T i E -STOP LULL - L ROTARY FAN: 1PRESS SLUDGE PUMP NO. 2 LLFJ P' M 10 C91B :........TO ROTARY FAN PRESS SLUD PUMP NO.2 CP NOTE 2 CD 11 N OTES: 1 INTERCEPT EXISTING CONDUIT USED FOR THE RELOCATED, INSTRUMENTS, EXISTING CABLE: IS TO BE PULLED AND RECONNECTED. IF CONDUCTORS ARE DAMAGED DURING RELOCATION. THEY MUST BE REPLACED :IN KIND. 2. REFER TO ONE LINE DIAGRAM AND BLOCK: DIAGRAM ON SHEETS E-11 AND E-12 FOR ni 1AKITITY Axin C17rr r)F-- (-r)Nim HT AKIn ROTARY FAN PRESS SLUD( TO MCC -1013 NOTE 2 ROTARY FAN PRESS SLUD( TO MCC -10B NOTE 2 SLUDGE PUMP ROOM PLAN EL 710.00 SCALE: 3/8" 9 AlmkRCImOIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWWARCADIS.COM LICENSE NO. C-1869 Know what's below. Call before you dig. Clay of".1r­e_ensbpfp,, pcigy ground Locates 1 s I f k:ffl 'wml q q uesft COG Water Rejs'q6r6es.,, 'Dept., , _;3�0-373-2033 GDOT Traffic""-,iiiqni�l� n �._��pt-373-2606 COG/Guilford:Co''T "i 36-373-208A 4 .9- COG Water S4 3-5655, Tanks/T�eatmtknt GDOT Stor%mN,�­.'' pl�111,water;"-373-2569 SEALS NCA 36 S z CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 2/01/2018 PERMIT NO. DATE ISSUED FOR BY COPYRIGHT: ARCAIDIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: E-4 DESIGNED BY: A. TAVERAS DRAWN BY: A. SUMNER CHECKED BY: S. STERN SHEET TITLE ELECTRICAL SHB SLUDGE PUMP ROOM PROPOSED PLAN SCALE: AS SHOWN CONTRACT SHEET 38 OF 48 SHEET E-4 OF 14 | u n � . . ... . ... ...... FE "o _ \ � `-—--------- --------7—"-------. | � ROTARY FAN PRESS TO BE RELOCATED " L] — | / 1� .---.��-----------------------------------------'-------------------...---.�.----------^ ----'---------------................ TO BE RELOCATED REFER TO SHEET E-7 FOR NEW LOCATION — RFP -[1 POWER PANEL TO BE RELOCATED REFER TO SHEET E-6 FOR NEW LOCATION ASH DEWATERING ROOM DEMOLITION PLAN EL 724.00 ^ NOTES: 1. REFER TO DEMOLITION ONE UNE ON SHEET E-10 FOR ASSOCIATED CONDUIT ] AND CONDUCTORS TO BE DEMOLISHED. iv. fmkRCADIS LEGAL ENTITY: NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 LICENSE NO. C-1869 Knowwhays below. Callbefore you dig. c"y of ground COG Water R, s, Dept.', -336-373-2033 COG/Guilfor 6-373-2084 COG Water, SO -373-5855 SEALS CA 36 CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 1 2/01/2018 PERMIT NO. DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: E-5 DESIGNED BY: A. TAVERAS DRAWN BY: A. TAVERAS CHECKED BY: S. STERN SHEET TITLE ELECTRICAL SHB - ASH DEWATERING ROOM DEMOLITION PLAN AS SHOWN CONTRACT SHEET 39 OF 48 SHEET E-5 OF 14 E i= 0 N 0 a 0 U) Q) d U 0 i W U W Ld i w i 0 N H 0 U 0 �r 0 a IL i 0 U a i a 0 U Z I Ln D Q elfU v a Q Ld Q a� NOTE 8 { EXISTING JUNCTION BOX FOR DUPLEX FILTRATE "PUM. P DONT `\ \ ........ TO BELT FILTER PRESS .CONTROL PANEL PPOILYM_ERi FLOW METER- ., I SPAN � a Er.. PIT...:.:... RELOCATED RFP -01 POWER PANEL N OTE 4 NOTE 6 N . _LD o Ld NORTH CAROLINA, INC. Q GREENSBORO, NORTH CAROLINA 27407 LdF FAX: 336-855-5648 WWW.ARCADIS.COM Ox h >--' =Z ¢x O 0°� J� a 1 Call before you dig. o Z �m o Z< tnO F — zw Lo C) _.:.. �... X LLA c) =) x 0 -- L 1..-. O =) _.O.O . 00..... I— -D � > F--' U L 1 1 NOTE 1 7 : �. ... .... ........—-mr,rr. ............. ._..�...`....- _�'�'�`—__— —tt—-----•——•....»—� �......... _ .`_—r -__+__._ ___ _...�_ _.amu— �_. 1 T' I —• NOTE 9 ! ; R i BELT FILTER PRESS CONTROL PANEL (BFP-CP) FE _ TASH FLOW METER NO. 1 NOTE 5-: k I x ^ � 4 iI l 4 f, 1 — ---------- i; i; TASH FLOW MET NOTE 5 i €' L I t r :I • jl E EE ! Y 6 x' ASH DEWATERING ROOM PLAN EL 724.00 0 21 4' 6. 2 NOTES: 1. CONDUIT TO BE ROUTED TO JUNCTION BOX PROVIDED IN VOLUME II, LOCATION OF JUNCTION BOX SHOWN ON SHEET E-3 OF VOLUME II. QUANTITY AND SIZE OF CONDUITS TO BE ROUTED SHOWN ON ONE LINE DIAGRAM ON SHEET E-9. 2. GROUND BELT FILTER PRESS FRAME WITH #4 AWG BARE COPPER CONDUCTOR IN 3/4" C TO BUILDING STEEL. 3. REFER TO ONE LINE AND BLOCK DIAGRAM ON SHEET E-11 FOR SIZE AND QUANTITY OF CONDUIT AND CONDUCTORS, 4. IF LENGTH OF EXISTING CONDUCTORS ARE INSUFFICIENT FOR NEW LOCATION NEW CONDUCTORS SHALL BE RUN FROM THE NEW LOCATION FOR POWER PANEL RFP -01 TO ASSOCIATED LOADS. CONTRACTOR TO VERIFY ALL CONDUCTORS LAND UPON CORRESPONDING CIRCUIT BREAKER AS IN THE EXISTING CONFIGURATION. EXISTING CONDUIT TO BE INTERCEPTED IF POSSIBLE. RFP -01 TO BE INSTALLED 18" ABOVE NEW CONCRETE FILL. 5. REFER TO M-8 FOR FLOW METER SECTIONAL VIEW. 6. INTERCEPT EXISTING CONDUIT ROUTED TO EXISTING ASH EQUIPMENT JUNCTION BOX. 7. REFER TO SHEET E-2 FOR LOCATION OF JUNCTION BOX. REFER TO SHEET C-2 FOR LOCATION OF EXISTING ASH EQUIPMENT. 8. REFER TO SHEET C-2 FOR EXISTING DUPLEX FILTRATE PUMP EQUIPMENT AND CONTROL PANEL LOCATION. 9. REFER TO SHEET E-9 FOR EXISTING POLYMER FEED PUMP CONTROL PANEL LOCATIONS. AfakRC/mOIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Knowwnat's below. Call before you dig. City of,?G ik3en L~o,Und"rounci Locales Irsf ons% ; �rciues#s ., COG Water ROsclO'r`ces Dept,3�-373-2033 „\ GDOT Traf#ic"Si60a1��� 36-373-21506 COG/Guilforc ,;Gq Tel ectm` > 6-373-2084 r COG Waten S 1 6 373 51355 � Y ' Tanks/Treat ert�?ng` GDOT StortnkVaer ` -373-2569 \ SEALS 'A CARO �� �' :•• �'•s —IV _ SEAL 6 tp CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT —014A 2017-014A 1 2/01/2018 PERMIT NO. DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: E-6 DESIGNED BY: A. TAVERAS DRAWN BY: A. TAVERAS CHECKED BY: S. STERN SHEET TITLE ELECTRICAL SHB — ASH DEWATERING ROOM PLAN SCALE: AS SHOWN CONTRACT SHEET '0 OF 48 SHEET E—fi OF 14 0 0 - RELOCATED POLYMER co N 00 I RELOCATED SLUDGE o�N 0 L C Q 0 I 0 O 0 I d rn I E p U I0 A 4 k � F 4 r \✓ E j€ E 71ETER - W ,METER 940 ��i .! 1..����.µG� ��. !...._..._'�....!'._.X�.�.....f..�l....F�+�.. _/�.. - .�_1, ��_..__. 6-c r:• � � �.��...�_t__1__�, ._ .__ _. _ 1 ,...�. _......._. -. ,..... _. ..a_. �.�./ .�. �... ...»» .��.�..... .. ..e__ = _� �. 0 ca r I ------- SS TO RFP CP- IT `A , TO RE PRESS - C \'71 50 - �-- 0' RELOCATED RFP CP 94.6 , 94- ) �►�-�-=� TO RELOCATED RFP CP TO RELOCATED RFP CP N I f I f I I Al ' FAN PRESS MOTOR OTARY FAN PRESS JI 4 ti E ATED ROTARY FAN NTROL PANEL (RFP C ELOCATED ROTARY F, OTE 1 A In SLUDGE PRESS ROOM PLAN — EL 742.00 ins NOTES: GROUND ROTARY FAN PRESS FRAME WITH #4 AWG BARE COPPER CONDUCTOR IN 3/4= C TO BUILDING STEEL. 2. REFER TO SHEET E-11, E--12 AND E-13 FOR SIZE AND QUANTITY OF CONDUIT AND CONDUCTORS. 3. REFER TO SHEET E-2 FOR LOCATION OF MCC -20. s,_,. ................_._. _ I 4. REFER TO SHEET E-9 FOR LOCATION OF ROTARY I PRESS POLYMER PUMP CONTROL PANEL LOCATIONS. 5. REFER TO SHEET E-4 FOR ROTARY PRESS SLUDGE I , PUMP CONTROL PANEL LOCATIONS. �-- ;TO RFP POLYMER FIT 940 1 TO RFP SLUDGE FIT' -940,A s PARCADIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SURE 208 GREENSBORO, NORTH CAROLINA 27407 TEL:- 336--292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's below. Cali before you dig, \� \V City of Greensboro Uncl round Locates Int /IR quests COG Water Rgsqurb.es Dept 4 -373-2033 GDOT Traffie"".g36-373--2606 COG/GuilfordCo Telsccam,36-373-2084 COG Water Sunni V�� !� ' %336-373 5855 Tanks/Teatjerl;IantsF GDOT Stoate6-373-2569 SEALS '40 �'�, `p���ss1otizz, 5E L . 3 tiEN Sfill tiffs 00` CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 12/01/20181 PERMIT NO. DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.D001 FILE NAME: E-7 DESIGNED BY: A. TAVERAS DRAWN BY: A. TAVERAS CHECKED BY: S. STERN SHEET TITLE E ? ITO ZO Q-' O O _ � . 0 0 O O n D > n > D �> Z Z Z ➢Z'' O m m m `m CA cn ,tn cn cn W u7 -0 m\ it r O O C c r- F- 0/2 0/2 K � .rr►-r�..._.-.. m m '\m ,f c m K: 9: c c z o O o z z m m O o� Cn m m s PARCADIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SURE 208 GREENSBORO, NORTH CAROLINA 27407 TEL:- 336--292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's below. Cali before you dig, \� \V City of Greensboro Uncl round Locates Int /IR quests COG Water Rgsqurb.es Dept 4 -373-2033 GDOT Traffie"".g36-373--2606 COG/GuilfordCo Telsccam,36-373-2084 COG Water Sunni V�� !� ' %336-373 5855 Tanks/Teatjerl;IantsF GDOT Stoate6-373-2569 SEALS '40 �'�, `p���ss1otizz, 5E L . 3 tiEN Sfill tiffs 00` CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 12/01/20181 PERMIT NO. DATE ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.D001 FILE NAME: E-7 DESIGNED BY: A. TAVERAS DRAWN BY: A. TAVERAS CHECKED BY: S. STERN SHEET TITLE IIto] 110IST_1I SHB — SLUDGE PRESS ROOM PLAN SCALE: AS SHOWN CONTRACT SHEET 41 of 48 SHEET E--7 of � 4 IL (D N E i= cu 0 N f r] \ 0 a n ar a 6 0 co i W / U W J W / W z 0 0 In 0 0 0 ry / 0 Q U Q ui I.� D 0 cn U z V) a U v Q V) V) W Q fn fn POLYMER FEED ROOM PLAN - EL 724.00 SCALE: 1/4" = V-0" NOTE: 1. COMMUNICATIONS TO SCADA IN EXISTING PANEL MUST BE PRESERVED —1 L WITHIN NEW INSTALLATION SHOWN ON SHEET E-9. 2. PROVIDE NEW CONTROL STATIONS TO REPLACE EXISTING POLYMER DAY TANK MIXER CONTROLS LOCATED IN EXISTING PANEL. MOUNT ONE NEW CONTROL STATION AT EACH POLYMER DAY TANK OBSERVATION PLATFORM TO CONTROL RESPECTIVE POLYMER MIXER. 3. DISCONNECT CONTROL CABLING AT ROTARY FAN PRESS CONTROL PANEL. CONDUCTORS TO BE CONNECTED TO NEW BELT FILTER PRESS CONTROL PANEL SHOWN ON SHEET E-6. EXISTING PANEL TO,- BE DEMOLISHED, AND REPLACED WITH TWO NEW: POLYMER PUMP VA1mkRC1m01S LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what% below. Call before you dig. Clty of�("ensboro Underground COG Water ReSaurces,,Dept..,_;336-373:-2033 GOOT Traffic>Sxgnal 336-373-2606 COG/Guilfordi;CII Telecgm _., 3.6-373-208A COG Water Suppler 336 373-5855 Tanks/Treatm,e0t:P1nS GDOT Storm-,Wae� 6-373-2569 SEALS 9 1� �EAENS (: '1111111111 , 7 - ? -$ Ei CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 I2/01/20181 PERMIT I NO. DATE I ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DO01 FILE NAME: E-8 DESIGNED BY: A, TAVERAS DRAWN BY: A. TAVERAS CHECKED BY: S. STERN SHEET TITLE I ELECTRICAL SHB -- POLYMER FEED ROOM DEMOLITION PLAN SCALE: AS NOTED CONTRACT SHEET 42 OF 48 SHEET E-8 OF 14 0 a a J rn N f 0 N T c 0 L a. C Q 0 0 0 a 0 rL 00 0 F= 0 N 0 0 0 6 U c� a I Ld i Ld U _j J Ld i w 1n i 0 0 1n 0 �t 0 cy IL 1-10 ai 0 W 0 Z I 60 0 a CL cn V) Q 0 m 0) yy�� �F iJ iC'hh''r+ 3 :r DRkN 1 3iu� i I 1 FEBRUARY 2018 PROJECT NO.: GRGRN104.D001 1 I I I t t l i DESIGNED BY: i - t I I I t I I f i A. TAVERAS i S. J 1 - I t I I it C5. _.. I -I - ( 3'j - A ROTARY FAN PRESS- PROLYMER PUMP NO. 1 CP • ' I ` U W U O ..0 O ... — a _j I I 1 m m Ld U bi C) r I / _2 ........__._ 0 0 0 0 !- 0 0 I _ _ I t j...,...,_ .,-...,..I I ROTARY FAN PRESS P a U CL ..� c) W )LYMER PI, N NOTE: 1. REFER TO ONE LINE DIAGRAM ON SHEET E-12 FOR SIZE AND QUANTITY OF —1 L CONDUIT AND CONDUCTORS. COMMUNICATIONS TO SCADA IN EXISTING PANEL MUST BE PRESERVED WITHIN NEW INSTALLATION. ]F 2. EXISTING POLYMER DAY TANK MIXERS TO BE CONNECTED TO NEW LOCAL CONTROL STATION WITH 6#14, 1"C. JMP NO. 2 CP . _ __...._.... -. _.. _....... -- ..... ... ....... _......._.._. NOTE 1 i ! I � �— ROTARY FAN PRESS 'POLYMER PUMP NO. 2 i TO RELOCATED RFP CP `� V TO RELOCATED RFP CP I T- / POLYMER 'DAY TANK NO. 1 VP, LV x POLYMER `DAY TANK NO. 2 VALVE � I XXIx� NOTE ;2 OTEr' POLYMER FEED ROOM PLAN - EL 724.00 SCALE: 1 /4" = 1'-0" 1 POLYMER DAY TANK MIXER LOCAL CONTROL STATION AtmkR0%D1S LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.CO�A LICENSE NO. C-1869 (now what's below. Call before you dig. Cht V of)a ensboro Underground Lodes Inforrnc'r n.m, ,quests COG Water Resources Dept X36-373-2033 GDOT Traffic, 6i9nal `336-373-2606 COG/Guilford C4 Telecomr.,336-373-2084 COG Water Supply "336-373--5855 Tanks/Treat�el}t GOOT Storm Water 336-373-2569 {5y ti*1y_lW +'%J1111111/f�` SE `= ''�,GjN AyEN S . S+ •+'+� CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 12/01/20181 PERMIT I NO. DATE I ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.D001 FILE NAME: E-9 DESIGNED BY: A, TAVERAS DRAWN BY: A. TAVERAS CHECKED BY: S. STERN SHEET TITLE 2102wrikir ".11 SHB - POLYMER FEED SCALE: W6161,71m1W_NN,. AS NOTED CONTRACT SHEET 43 OF 48 SHEET E--9 OF 14 0. C7 O I w V J w LaJ 2 En O N F— CD C7 0 O or 0- a U Ui I.� O U Z I U P CL V) w m m RELOCATED PANEL RF F-01 480VAC, 3c), 3w, 225A T`II-PLATED COPPER BUS, 42KAIC MIN DUPLEX FILTRATE PUMP CONTROL PANEL :,--f CRINDE;R CONTROL PANEL FVR 15.AT i U r O 0 ASH PUMP "'ON-'ROL PANEL �_ C3 ` GRGRN104.DOO1 r cti3 _ry < Z 4 D A. w r U - # W N N N N cl v < L 0 a U T r = r r x r W CV.. CY N N N LL- I� Li_ ,- N N Z t~O Y r HAT ;6�8 M S (�s r- 0 Q N -tz N Z*= ' kLj ` FEBRUARY 2018 ` GRGRN104.DOO1 d E-11 _ry < Z 4 D A. w r U Q- La_ Q - W N N FROM MCC -2,0 REFER TO E--11 FOR CONDUCTOR AND CONDUIT SIZE AND QUANTITY 22j�� � 22-5AT f � �'✓) l� 1 f / t0� (s) 08 10 100hAr- 100AF 1000 100 A,7- 100, A;= 1 00A 1 ✓�T , OAT 90 AT ,, "It-, AT I5Ar -,AT) 15 AT - U U r N ILLI &L� W LU c� Q u:. C It- O < o < < Q < Ul gin. (f) cn 0 to BELT FILTER PRESS CONTROL PANEL (BY MANUFACTURER) VFD Yi- I �I ca i I U U U I i o d o w � r d O O AI' EL 24h � P_G2 '208Y[I 20V 2 7.5 XD 3w, 4`W 50A MCP LalU =UjW J m w o ¢ Q o Q z 0 POWER PANEL RFP -01 POWER ONE LINE PROPOSED t? N NO SCALE NOTES: 1. CONTRACTOR TO PULL CONDUCTORS PROVIDED IN VOLUME II FROM VOLUME II PROVIDED JUNCTION BOX FOR BELT FILTER PRESS TO CONNECT TO NEW ASH PUMP DESIGNED IN VOLUME II. 2. CONTRACTOR MUST TEST ANY EXISTING CONDUIT AND CONDUCTORS BEFORE RECONNECTING/REUSING WITH RELOCATED AND NEW EQUIPMENT. IF TEST DOES NOT PASS NEW CONDUCTORS AND CONDUIT MUST BE PROVIDED. 3. REFER TO SHEET E-2 FOR LOCATION OF EXISTING PLC. TXRFP 15 -kVA, Sts 80-208r 20V S.S. HOU'SINC TO PLC G--- R i TO PLC 12 E-HERNET/IP FTHERNET/IP COININECTIO\ "CONNECTION RELOCATED RFP CP 6#14, 1#12G, 1-C NOTE 3 1"C SPARE U NOTE 3 U CL a(n as U U U V .... -................ -............... _._._......._.... DUPLEX BELT FILTER PRESS CONTROL I R(3TARY FAN PRESS CONTROL.. F-ILfRATE PUMPI CONTPOL PANEL PANEL I PANELCBV, 3/4"C (BY MANUFACTURER) "EXISTING) i CBV, 3/4"C CBV, 3/431C ' CBV, 3/4"C U `0 x � r � r, � IN CA (A N N CD r V � V N N N 000 N tip POLYMER P0LYMER AS1I ASH pUIv9P PUMP tiRINDER PUMP CONITROL.. CONTROI-. C;ONTROF. CONTROL PANEL. PANEL PANEL PANEL BELT FILTER PRESS CP INTERCONNECT BLOCK DIAGRAM FEBRUARY 2018 U U GRGRN104.DOO1 FILE NAME: E-11 DESIGNED BY: A. w r U w W W N N N N SHEET TITLE Q < t6 �_ W O W U r U T r = r r x r W CV.. CY N N N LL- I� Li_ ,- N N Z t~O Y r HAT ;6�8 M S (�s 875 0 Q N -tz N Z*= U %875B lS ` 1VSw E FE FIE FIE :DOfDIf 8 �0- a_13 - BELT Z Z RFP POLYMER RFP POLYMER PRESS VOLUME II PUMP NO. 1 PUMP NO. 2 JUNCTION } O ck� Of v < CY. CL Lt ^.. L� � Ld z? U f r r - NOTE 1 M. 0 0 N N r PSH PSN r r 920 930 L U `0 x � r � r, � IN CA (A N N CD r V � V N N N 000 N tip POLYMER P0LYMER AS1I ASH pUIv9P PUMP tiRINDER PUMP CONITROL.. CONTROI-. C;ONTROF. CONTROL PANEL. PANEL PANEL PANEL BELT FILTER PRESS CP INTERCONNECT BLOCK DIAGRAM NO SCALE €�1 U a 0 N CBV, 3/4"C U FEBRUARY 2018 U U GRGRN104.DOO1 FILE NAME: E-11 DESIGNED BY: A. TAVERAS DRAWN BY: U r r CHECKED BY: S. STERN SHEET TITLE UO W O W U r U T r = r r x r N J =1m d0 DO O. N [� N 0Z COU Z t~O Y r N � 0 Q N -tz N Z*= CIA U :DOfDIf �0- a_13 - BELT FILTER PROVIDED IN RFP POLYMER RFP POLYMER PRESS VOLUME II PUMP NO. 1 PUMP NO. 2 JUNCTION JUNCTION CONTROL CONTROL BOX BOX PANEL PANEL z? U f r r - NOTE 1 N N r PSH PSN r r 920 930 L PRESSURE PRESSURE x r SWITCH SWITCH NO SCALE €�1 U a 0 N CBV, 3/4"C U PRESSURE PRESSURE SWITCH SWITCH ROTARY FAN PRESS BLOCK DIAGRAM NO SCALE POARCADIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's below. Call before you dig. Clay of Greensboro underground Locates Information/Rerquests COG Water Re" ces.,Dept,.-336-373-2033 GOOT Traffic Signal. X35-373-2606 COG/Guilford Co TdiiioikLL 36-373-2084 ,, / COG Water SU#piy, ��6 -373-5855 Tanks/Treatment GDOT Storm.Weter 336-373-2569 SEALS ,���llllllrrrr!! SI0 1 SE L _ 23 9 r r GIN �!r!!) 11 2 --( CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 1 12/01/20181 PERMIT I I I N0. I DATE I ISSUED FOR I BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DOO1 FILE NAME: E-11 DESIGNED BY: A. TAVERAS DRAWN BY: A. TAVERAS CHECKED BY: S. STERN SHEET TITLE U U N v- f r r r It L x r r U r N N CV Q- N N N N N n N a N N (n� (n � (I'1 r N to z4h QD (0 U V U V N N N N z N � N O LID 0 N N I� _._ASH RFP SLUDGE FIT 94G f FIT 940 PIT ISI-.� � ce ASH RFP SLUDGE I ~ ROTARY B11 SOLIDS BIOSOLIDS PUMP NO. 1 PUMP N0. 2 .� , 4 .- 955 PRF_55 GRINDER CO{�Th',r:;L GRINDER CONTROL CONTROL PANEL CONTROL PANEL � r / y `�ao) � . � - - � � � � r � `1 `' ;_lP ICT ION �., =' �� B(;, PANEL F'/1IWEL Li < Ua ai �uj .. ._.. __1 C) t� r ilJ VJ 7 J w ;J U LL 0 LL a l 1. l I.s.! Ll k r I.A_I LJ oL _ � y w; a r- 4 7 ra Z C)- I --- -O N 04r1 PSH PSH 900 910 PRESSURE PRESSURE SWITCH SWITCH ROTARY FAN PRESS BLOCK DIAGRAM NO SCALE POARCADIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 Know what's below. Call before you dig. Clay of Greensboro underground Locates Information/Rerquests COG Water Re" ces.,Dept,.-336-373-2033 GOOT Traffic Signal. X35-373-2606 COG/Guilford Co TdiiioikLL 36-373-2084 ,, / COG Water SU#piy, ��6 -373-5855 Tanks/Treatment GDOT Storm.Weter 336-373-2569 SEALS ,���llllllrrrr!! SI0 1 SE L _ 23 9 r r GIN �!r!!) 11 2 --( CITY OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 1 12/01/20181 PERMIT I I I N0. I DATE I ISSUED FOR I BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.DOO1 FILE NAME: E-11 DESIGNED BY: A. TAVERAS DRAWN BY: A. TAVERAS CHECKED BY: S. STERN SHEET TITLE ELECTRICAL RFP -01 POWER ONE LINE, RFP CP AND BFP CP BLOCK DIAGRAM PROPOSED SCALE: NONE CONTRACT SHEET 45 OF 48 SHED E-11 OF 14 it Q) C O Z W C.� Q 3 'O L: 0 OD I O c� N X 1-11O N F- 0 O CE U_ / a U J LL. W X ro Ln ui E i= co O N O to w Q7 O a () O cn Q) Q U in O D tV I W LJ W J W W T O N F- 0 O U O O 0 a U Q N k1 O V) U Z I N a U Q) Q. V) x W Q L Qi U) CM C r U C O Z (%l W c� a rn 3 ami 'o O m I O C7 m X O O V) 0 O O d / ¢ U f%I W nf x a M W U W J W W 2 U) O 0 c� O O D_ D Q V Q ai li O U Z I V) Q U (D Q Q� L� Q L a) cn n MOUNTING CHANNEL ATTACH TO WALL OR SUPPORT MEMBERS WITH EXPANDABLE ANCHORS, MACHINE BOLTS AT OTHER LOCATIONS. (3/8") MIN GALVANIZED f REFER TO PLANS FOR ♦ THREADED ROD, TYP. QUANTITY & SIZE OF / _ CONDUITS LOCKING SQUARE WASHER & L.00KNUT CONDUITS SPACE MOUNTING CHANNEL ` - INTEGRAL m p AT MIN. 4'-0" INTERVALS GALVANIZEDLIPPED STEEL O a USE MANUFACTURED CONDUIT MOUNTING STRAPS FOR ATTACHING CHANNEL m CONDUITS WASHER & O m LOCKNUT O WALL OR SUPPORT MEMBER BOLTS �NcTy CONDUIT GENERAL NOTES: `--CONDUIT STRAP MOUNT CONDUITS AT HEIGHT AS REQUIRED. CONDUIT MOUNTING DETAIL USE FOR TWO OR MORE CONDUITS RUN PARALLEL SCALE: NTS UNISTRUT MIN. 1 -1/4"* -C LEN GTH TO SUIT MIN. 1-1/2" CONDUIT SUPPORT DETAIL SCALE: NTS 1. INTEGRAL MOUNTING CHANNEL LONGER THAN (36") SHALL BE INSTALLED WITH A CENTER SUPPORT ROD. 2. FASTEN THREADED ROD TO STRUCTURE BY APPROVED METHOD PER SPECIFICATION. FIELD VERIFY EXACT CONDITIONS. CONDUIT CLAMP. SIZE AS RE^""'�^ INTEGRAL GALVAN I Z E LIPPED S1 MOUNTING CHANNEL CONDUIT TRAPEZE MOUNTING DETAIL SCALE: NTS EXPANSION FITTING WITH BONDING JUMPER FLOOR OR ROOF STRUCTURE. FIELD VERIFY ACTUAL CONDITIONS, TYP: SPRING NUT PROVIDE EXTRA CABLE TO MAKE COMPLETE LOOP AROUND BOX PERIMETER SEISMIC OR EXPANSION STRUCTURAL MEMBER (BEAM, JOIST, ETC.), TYP. STEEL EXPANSION ANCHOR -7 JUNCTION BOX, TYP (SIZE AS REQUIRED) INTEGRAL GALVANIZED LIPPED STEEL MOUNTING CHANNEL JUNCTION BOX (SIZE AS REQUIRED) CONDUIT FITTING CONDUIT EXPANSION JOINT CROSSING DETAIL EXPANSION FITTING SCALE: NTS SEE NOTE 1 Se F VARIES - SECTION AA 96- r SOMETRIC FIN. ( SECTION AA NOTES FOR ELECTRICAL EQUIPMENT RACK: 1. COORDINATE W/SHOP DWGS. OF EQUIP. USED. MAX. HORIZ. SPAN SHALL BE 5'-0" WITHOUT ADDITIONAL VERT. SUPPORTS. 2. FABRICATE FROM ALUMINUM WELDED CONSTRUCTION. EQUIPMENT RACK DETAIL SCALE: NTS GROUT POST IN 6" DIA. x 9" DEEP PRECAST HOLE. EMBED A MIN. OF 8" (TYP.) 'ACE/CONC. IEYOND - #4's EA. FACE (TYP.) 1mkRC A IAOIS LEGAL ENTITY: ARCADIS G&M OF NORTH CAROLINA, INC. ONE CENTERVIEW DRIVE, SUITE 208 GREENSBORO, NORTH CAROLINA 27407 TEL: 336-292-2271 FAX: 336-855-5648 WWW.ARCADIS.COM LICENSE NO. C-1869 r r Know 111 haft below. Call before you dig. CFty of iesnsboro-Underground Locates Inforrma*?NlR nests COG Water ResoUrces,:Oept..36-373-2033 GODT Traffip"`$rgoal ` 36-373-2606 COG/GuiIford Te] -373-2084 �o ec0� COG Water Supply"_ 36-373-5855 Tanks/Treittnent;;f�l�nt GDOT Storm .Mater ' \ \ >' 36-373-2569 SEALS � Cq���yyyS�rli��i R '.f. 0 .�F55j0 _S L23E9 h CIN OF GREENSBORO WATER RESOURCES DEPARTMENT T.Z. OSBORNE WATER RECLAMATION FACILITY IMPROVEMENTS VOLUME I ASH PRESS REPLACEMENT 2017-014A 1 2/01/20181 PERMIT NO. DATE I ISSUED FOR BY COPYRIGHT: ARCADIS G&M OF 2018 NORTH CAROLINA, INC. DATE: FEBRUARY 2018 PROJECT NO.: GRGRN104.D001 FILE NAME: E-14 DESIGNED BY: A. TAVERAS DRAWN BY: A. TAVERAS CHECKED BY: S. STERN SHEET TITLE ELECTRICAL ELECTRICAL DETAILS SCALE: NONE CONTRACT SHEET 48 OF 48 SHEET E-14 OF 14