CERTIFIED MAIL: RETURN RECEIPT REQUESTED
Mr. Ken Beuley
TKC CXXVIII, LLC
5935 Carnegie Boulevard, Suite 200
Charlotte, NC 28209
Project Name: Crate and Barrel Distribution Center
REQUEST FOR MORE INFORMATION
Dear Mr. Beuley:
DWQ EXP # 08-0965v3
Lincoln County
On February 24, 2009, the Express Review Program of the Division of Water Quality (DWQ) received
your Stormwater Managemnt Plan Application for the above referenced project. The DWQ has
determined that your application will require additional information. Please provide the following
information so that we may continue to review your project and prevent return of your application as
required by 15A NCAC 2H .0506:
Additional Information Requested
1. All Wet Ponds:
a. The normal (permanent) pool elevation shall be located in the midsection of the 10-foot
vegetated shelf such that the bottom 6 inches of the shelf will be permanently under water
while the top half will be occasionally inundated by stormwater runoff.
b. Determining the required surface area of a wet pond is an iterative process (one iteration
typical, after initial trial depth). Please use the average depth as computed on the supplement
form to determine the surface area-to-drainage area (SA/DA) ratio from the table, and
subsequently compute the required surface area. Using this process and the information
provided, Wet Pond 1 was found to be inadequately sized. You may increase the surface area
or pond depth.
c. Planting Plan: The plants schedule table on Sheet SWMP L1 needs to be revised. Wet Pond 2
has been repeated (instead of Wet Pond 3), and the total of individual plants do not match the
sum of plants from all three wet ponds.
d. This office recommends the use of plunge pool (rip rap basin) at the BMP pipe outlet instead
of the flat rip rap apron to further reduce pipe outlet velocities.
e. The geotechnical report indicates Silty Fine Sand soils within 10.0 feet from the ground
surface at most locations especially where the ponds are located. Please specify on the plans
that the bottom and sides of the ponds shall be compacted, or constructed of clayey material
to maintain the normal pool by preventing the water from quickly draining into the soil.
401 Oversight/Express Review Permitting Unit One
1650 Mail Service Center, Raleigh, North Carolina 27699-1650 NorthCarolina
Location: 2321 Crabtree Blvd., Raleigh, North Carolina 27604 -Vaturally
Phone: 919-733-17861 FAX: 919-733-6893
Internet: http://h2o.enr.state,nc.us/ncwetlands/
An Equal Opportunity 1 Affirmative Action Employer
Ken Beuley
08-09650 Crate and Barrel SNIP
Page 2 of 2
February 25, 2009
f. Please revise any affected calculations, tables, plans and cross sections and submit 2 copies of
the revised documents.
Please respond within five (5) days of the date of this letter by sending two (2) copies of the above
information in writing. The Express Review Program is a process that requires all parties to participate in
a timely manner.
This letter only addresses the application review and does not authorize any impacts to wetlands, waters or
protected buffers. Please be aware that any impacts requested within your application are not authorized (at
this time) by the DWQ.
Please contact Joseph Gyamfi or Lia Myott Gilleski at 919-733-1786 if you have any questions regarding or
would like to set up a meeting to discuss. this matter.
Sin rely,
Cyndi Karoly, Supervisor
1401 Oversight/Express Review Permitting Unit
CBK/jg
cc: Steve Chapin, USACE Asheville Regulatory Field Office
Alan Johnson, DWQ Mooresville Regional Office
File Copy
Matt Matthews, DWQ Wetlands and Stormwater Branch Manager
Mansour Edlin Consulting, 1515 Mockingbird Lane Suite 802 Charlotte, NC 28209
=y??1?7?: •• i;)?i71?»????'IC.'iF??iIC?IJ? • u • • ? ? ? ? :?'
¦ Complete items 1, 2, and 3. Also complete
item 4 if Restricted Delivery is desired.
¦ Print your name and address on the reverse
so that we can return the card to you.
¦ Attach this card to the back of the mailpiece,
or on the front if space permits.
1. Article Addressed to:
TKC CXXVIII,LLC
Attn; Mr. Ken Beuley
5935 Carnegie Boulevard Suite 200
Charlotte, NC 28209
DWQ# 08-0965-v3-Lincoln
ure
? Agent
? Addre
C. Date of Delivery
D. Is delivery address different from item 1? ? Yes
If YES, enter delivery address below: ? No
3. Service Type
Certified Mail ? Express Mail
Registered 10 Return Receipt for Merchandise
? Insured Mail C.O.D.
4. Restricted Delivery? (Extra Fee) ? Yes
2. Article Number 7008 3230 0003 1103 3923
(transfer from Semite labe
PS Form 3811, February 2004 Domestic Return Receipt 102595-02-M-1540
UNITED STATES. POSTAL SERVICE First Glass Mail ,.. ;
Postage & Fees..P-ald
Permit FIo G 10
• Sender: Please print your name, address, and Z0*471-n"this box • °'
NC DENR Division of Water Ouality
401 Oversight/Express Unit
2321 Crabtree Boulevard, Suite 250
Raleigh, NC 27604