February 8, 2018
Mr Charles Hawkins, Mayor
Town of Saratoga
PO Box 207
Saratoga, NC 27873
Subject Compliance Evaluation Inspection
Town of Saratoga Collection System
No WQCSD0008
Wilson County
Dear Mr Hawkins,
Water Resources
perm►W►n9 Secy►on
On February 8, 2018, Rick Trone of the Raleigh Regional Office conducted an inspection of the
collection system at the subject facility The collection system is deemed permitted through 15A NCAC
02T 0403 Present during the inspection was Mr M J Jackson, Operator in Responsible Charge (ORC)
His cooperation during this inspection was appreciated Findings during the inspection were as follows
1 The system consists of seven pump stations of which six are in operation Five pump stations
were inspected and inspection logs were up to date The findings of each pump station are as
follows
a Rogers Street/ballfield identified by signage, secure access, audio/visual alarms
functioned when the high-water floats were activated and pumps were operational The
generator is tested weekly and during the inspection it was tested successfully
b Speight School there is no fence surrounding station, however, the equipment is locked
and identified with signage The ORC indicated this station was not in active use
c Varnell Drive identified by signage, secure access, the audio alarm functioned, however,
the visible alarm was not working Both pumps were operational
d Triangle identified by signage, secure access, audio/visual alarms functioned when the
high-water floats were activated and both pumps were operational On-site generator did
not start when power to station was cut Mr Jackson called RRO later to report a fuse
was found blown in the generator and had been replaced The generator is now working.
This station informs operator and Town Hall via telephone call This feature worked at
the time of the inspection
e. Page Street identified by signage, secure access, audio/visual alarms functioned when
the high-water floats were activated and pumps were operational.
2 ORC indicated no high priority sewer lines are in the system
A Fats, Oils and Grease Program (FOG) is implemented and in use Educational material on
FOG is mailed out twice per year As discussed, please ensure bi-annual distribution of
educational materials is implemented per permit requirements
Division or Water Resources, Raleigh Regional Off -ice, Nater Quality Operations Section http //portal ncdeni org/web/wdtaps
1628 Mail Service Center, Raleigh, NC` 27699-1628 Phone (919) 791-4200
Location 3800 Banett Drive, Raleigh, N'C 27609 Fax (919) 788-7159
4 Adequate records are being maintained pertaining to SSO's The last reportable SSO occurred on
April 2017 and the volume was 400 gallons
5 An up-to-date map of the collection system was available which included direction of flow, pipe
size and diameter, pump station ider_tification and location
The Town did not have a plan to clean sewer lines and no issues related to cleaning have
occurred The town has an agreement for the City of Wilson to inspect sewer lines with camera
-quipment
Please respond to item lc, updating this office when this deficiency is addressed. Please respond by
March 8, 2018.
If you have questions concerning this report please contact Rick Trone at 919-791-4257 or e-mail at
rick trone@ncdenr gov
Sincerely,
/ 2,
S Daniel Smith, Regional Supervisor
Water Quality Regional Operations Section
cc RRO, SWP
Central Files
Compliance Inspection Report
Permit WQCSD0008 Effective 03/01/00 Expiration Owner Town of Saratoga
SOC Effective Expiration Facility Saratoga Collection System
County Wilson
Region Raleigh
Contact Person Charles T Hawkins Title Nlayor Phone 252-238-3487
Directions to Facility
System Classifications CS1,
Primary ORC Certification Phone
Secondary ORC(s)
On -Site Representative(s)
Related Permits
Inspection Date 02/08/2018 Entry Time 09 OOAM Exit Time 10 30AM
Primary Inspector Rick V Trone Phone 919-791-4200
Secondary Inspector(s)
Reason for Inspection Routine Inspection Type Collection System Inspect Non Sampling
Permit Inspection Type Deemed permitted collection system management and operation
Facility Status ® Compliant ❑ Not Compliant
Question Areas.
® Miscellaneous Questions Performance Standards Operation & Maint Reqmts
® Records ® Inspections ® Pump Station
(See attachment summary)
Page 1
Parmit WQCSD0008 Owner . Facility Town of Saratoga
Inspection Date 02/08/2018 Inspection Type Collection System Inspect Non Sampling Reason for Visit Routine
Inspection Summary
Page 2
Permit WQCSD0008 Owner - Facility Town of Saratoga
Inspection Date 02/08/2018 Inspection Type Collection System Inspect Non Sampling Reason for Visit Routine
Performance Standards
Yes No NA NE
Is Public Education Program for grease established and documented? ■ ❑ ❑ ❑
What educational tools are used?
Mailings, two times per year
Is Sewer Use Ordinance/Legal Authority available? ❑ ❑ ■ ❑
Does it appear that the Sewer Use Ordinance is enforced? ❑ ❑ ❑
Is Grease Trap Ordinance available? ❑ ❑ 1:10
Is Septic Tank Ordinance available (as applicable, i e annexation) ❑ ❑ 1:10
List enforcement actions by permittee, if any, in the last 12 months
na
Has an acceptable Capital Improvement Plan (CIP) been implemented?
❑ ❑ i ❑
Does CIP address short term needs and long term \"master plan\" concepts?
❑ ❑ E ❑
Does CIP cover three to five year period?
❑ ❑ 0 ❑
Does CIP include Goal Statement?
❑ ❑ E ❑
Does CIP include description of project area?
❑ ❑ ® ❑
Does CIP include description of existing facilities?
❑ ❑ N ❑
Does CIP include known deficiencies?
❑ ❑ ® ❑
Does CIP include forecasted future needs?
❑ ❑ ® ❑
Is CIP designated only for wastewater collection and treatment?
❑ ❑ E ❑
Approximate capital improvement budget for collection system?
Total annual revenue for wastewater collection and treatment?
CIP Comments
na
Is system free of known points of bypass?
E ❑ ❑ ❑
If no, describe type of bypass and location
No points of bypass noted
Is a 24-hour notification sign posted at ALL pump stations?
® ❑ ❑ ❑
# Does the sign include
Instructions for notification?
® ❑ ❑ ❑
Pump station identifier?
® ❑ ❑ ❑
24-hour contact numbers
® ❑ ❑ ❑
If no, list deficient pump stations
None deficient in signage
# Do ALL pump stations have an "auto polling" feature/SCADA?
❑ ® ❑ ❑
Number of pump stations
7
Number of pump stations that have SCADA
0
Number of pump stations that have simple telemetry
2
Page 3
ti abed
® ❑ ❑ ❑
® ❑ ❑ ❑
❑ ❑ ❑
3N VN ON saA
❑ ® ❑ ❑
❑ ® ❑ ❑
❑ ❑ ❑ M
❑ ❑ ❑
®❑❑❑
1:11:1 ❑
❑❑❑■
❑❑❑0
®❑❑❑
3N VN ON sal.
m ❑ ❑ ❑
0
e,algellene spJoaaa 6wuealo wa;sls aJV
6/ou961awa ue;o;uana aq; ui algissaooell;uajjno s(em-;o-;q6u ajV
aalgePene sleM-10-;q61i Jo; sp.1o3aj aoueua;uiew aJV
e,(;ipgegaj dwnd ohm uoi;e;s dwnd goea jo; dwnd meds auo;seal;e ojeq; sl
6;uawdinba iGeipxne pue ti;awala; 'swaele bugoedsul
e,;uewdinbe jaq;o pue sdwnd 6u1jeoi.gnl pue 6ugoadsul
esanlen Ile 6u1SIOJ2xa pue 6ugoodsul
61enowaJ sugap pue 6umealo apis;no pue apisul
apnloui s6ol uoi;e;s dwnd op
e,;uawdinbe (gpue;s/(oua6iawa 6ugsa; jo; alnpagos aq; si;egM
e,;uewdinba /gpue;sj (oue6jewa 6w;sa; ao; pou,e;uiew alnpagos a sl
e_ajgepene;uawdlnbe jo; spjooei aoueua;wew aiV
siseq jelrBei uo smalna1 oho
e,seaje welgad pue s6ol suoi;eiado Q 'aoueua;uiew 'uogoadsui 6uim91AGJ ao; alnpagos aq; sl;egM
6seaje welgojd wja;-}jogs pa;uawnoop sseippe o; sueld aneq aoswadns aq; saoa
e,siseq jelnbej e uo sNooq bol Ile mav�aa josmiadns sao❑
6algepene sNooq bol Ile aiy
s;uawailn aM aoueua;uI?JN'g uol;eja p
Iuawwoo IDN ;uewwoo
e,sq;uow xis;sel ui sawl A;uoud-gbiq;o suogoadsui ler sin uaaq aneq; seH
6seuq (;uoud-g6iq;o suoi;oadsui;uewnoop;eg; algepene SPJ009J aJV
6aeal;sel aqa ul sewe a;owaa;o uoi;enjasgo ue uaaq aJaq; seH #
6wa;s(s an;ua;o uoi;enjasgo lenuue ue;onpuoo o; wa;sfs e aneq noA oa #
6s;weldwoo uezi;io;uawnoop;eq; algepene spaooaJ aJV
6 (ep Cana pa;oadsui suoi;e;s dwnd paddinba fu;awala;fyQVoS-uou ejV
6)JaOM e aouo;seal;e pa;oadsul suoge;s dwnd paddinbe fi;awela; jo V(]VOS aaV
e,suogoadsui uoi;e;s dwnd ;uawnoop;eq; algepene spooei ajy
e elgepene sawl JaMas Jo; spjooaj aoueua;wew ajy
suol;oa sub
GJIS uo saojeJaua aneq anlJ a;8waj9j aiwls aneq suoge;s dwnd oMl Juawwoo
sjo;ejaua6
aneq suoi;e;s dwnd uanas;o anis swaele 6uianp PH umol pue oho o; lleo euogd puss suoi;e;s dwnd oml
aquosa4
e,pa;uawelcwi a;ep 'SGA ji #
e,wei6oid la;uoo;ooi a aneq aeulujad aq; saoa #
sauawaimbai;iwjad;aawjou op ;eq; suoi;e;s dwnd ;o jegwnN
g swiele lensm pue appne (luo aneq;eq; suoge;s d_und;o jagwnN
augnoa ;isin Jo; uOSeaZI 6ugdweS uoN joadsul wags (S uogoalloo adRl uot;oadsul SLOZ/8oZ0 a;ea uoi;oadsul
ebo;ejes;o umol 41111oe3 - Jaumo 80004SC)DM ;iw18d
Permit WQCSD0008 Owner - Facility Town of Saratoga
Inspection Date 02/08/2018 Inspection Type Collection System Inspect Non Sampling Reason for Visit Routine
Has at least 10% of system been cleaned annually? ❑ M El EJ
What areas are scheduled for cleaning in the next 12 months?
Town indicated no line cleaning is done because there have been no issues There is an agreement with the
Town of Wilson to inspect lines using camera equipment
Is a Spill Response Action Plan available? El ❑ M
Does the plan include
24-hour contact numbers
i ❑ El
Response time
❑ ❑ 00
Equipment list and spare parts inventory
❑ ❑ 0 M
Access to cleaning equipment
■
Access to construction crews, contractors, and/or engineers
❑ ❑ ® ❑
Source of emergency funds
® El R ❑
Site sanitation and cleanup materials
❑ El 0
Post-overflow/spill assessment
❑ ■
Is a Spill Response Action Plan available for all personnel?
■ F ❑
Is the spare parts inventory adequate?
El ❑ ❑
Comment Operators and other staff have correct numbers to call If spell occurs
® ❑ R D
Records
Yes No NA NE
Are adequate records of all SSOs, spills and complaints available?
Are records of SSOs that are under the reportable threshold available?
Do spill records indicate repeated overflows (2 or more in 12 months) at same location?
1:1 El 0 El
If yes, is there a corrective action plan?
❑ ❑ ® ❑
Is a map of the system available?
® El R ❑
Does the map include
Pipe sizes
® ❑ ❑ ❑
Pipe materials
Pipe location
® 0 F-1 D
Flow direction
® ❑ R D
Approximate pipe age
® El F-1 El
Number of service taps
® El 0 El
Pump stations and capacity
® ❑ ❑
If no, what percent is complete?
List any modifications and extensions that need to be added to the map
None
# Does the permittee have a copy of their permit?
El El 1:1 Iff
Comment
Page 5