Loading...
HomeMy WebLinkAboutWQCSD0008_Compliance Evaluation Inspection_20180208Water Resources ENVIRONMENTAL QUALITY ROY COOPER Govet not MICHAEL S REGAN Sect etmy LINDA CULPEPPER Into int Dit ectot February 8, 2018 Mr Charles Hawkins, Mayor Town of Saratoga PO Box 207 Saratoga, NC 27873 Subject Compliance Evaluation Inspection Town of Saratoga Collection System No WQCSD0008 Wilson County Dear Mr Hawkins, Water Resources perm►W►n9 Secy►on On February 8, 2018, Rick Trone of the Raleigh Regional Office conducted an inspection of the collection system at the subject facility The collection system is deemed permitted through 15A NCAC 02T 0403 Present during the inspection was Mr M J Jackson, Operator in Responsible Charge (ORC) His cooperation during this inspection was appreciated Findings during the inspection were as follows 1 The system consists of seven pump stations of which six are in operation Five pump stations were inspected and inspection logs were up to date The findings of each pump station are as follows a Rogers Street/ballfield identified by signage, secure access, audio/visual alarms functioned when the high-water floats were activated and pumps were operational The generator is tested weekly and during the inspection it was tested successfully b Speight School there is no fence surrounding station, however, the equipment is locked and identified with signage The ORC indicated this station was not in active use c Varnell Drive identified by signage, secure access, the audio alarm functioned, however, the visible alarm was not working Both pumps were operational d Triangle identified by signage, secure access, audio/visual alarms functioned when the high-water floats were activated and both pumps were operational On-site generator did not start when power to station was cut Mr Jackson called RRO later to report a fuse was found blown in the generator and had been replaced The generator is now working. This station informs operator and Town Hall via telephone call This feature worked at the time of the inspection e. Page Street identified by signage, secure access, audio/visual alarms functioned when the high-water floats were activated and pumps were operational. 2 ORC indicated no high priority sewer lines are in the system A Fats, Oils and Grease Program (FOG) is implemented and in use Educational material on FOG is mailed out twice per year As discussed, please ensure bi-annual distribution of educational materials is implemented per permit requirements Division or Water Resources, Raleigh Regional Off -ice, Nater Quality Operations Section http //portal ncdeni org/web/wdtaps 1628 Mail Service Center, Raleigh, NC` 27699-1628 Phone (919) 791-4200 Location 3800 Banett Drive, Raleigh, N'C 27609 Fax (919) 788-7159 4 Adequate records are being maintained pertaining to SSO's The last reportable SSO occurred on April 2017 and the volume was 400 gallons 5 An up-to-date map of the collection system was available which included direction of flow, pipe size and diameter, pump station ider_tification and location The Town did not have a plan to clean sewer lines and no issues related to cleaning have occurred The town has an agreement for the City of Wilson to inspect sewer lines with camera -quipment Please respond to item lc, updating this office when this deficiency is addressed. Please respond by March 8, 2018. If you have questions concerning this report please contact Rick Trone at 919-791-4257 or e-mail at rick trone@ncdenr gov Sincerely, / 2, S Daniel Smith, Regional Supervisor Water Quality Regional Operations Section cc RRO, SWP Central Files Compliance Inspection Report Permit WQCSD0008 Effective 03/01/00 Expiration Owner Town of Saratoga SOC Effective Expiration Facility Saratoga Collection System County Wilson Region Raleigh Contact Person Charles T Hawkins Title Nlayor Phone 252-238-3487 Directions to Facility System Classifications CS1, Primary ORC Certification Phone Secondary ORC(s) On -Site Representative(s) Related Permits Inspection Date 02/08/2018 Entry Time 09 OOAM Exit Time 10 30AM Primary Inspector Rick V Trone Phone 919-791-4200 Secondary Inspector(s) Reason for Inspection Routine Inspection Type Collection System Inspect Non Sampling Permit Inspection Type Deemed permitted collection system management and operation Facility Status ® Compliant ❑ Not Compliant Question Areas. ® Miscellaneous Questions Performance Standards Operation & Maint Reqmts ® Records ® Inspections ® Pump Station (See attachment summary) Page 1 Parmit WQCSD0008 Owner . Facility Town of Saratoga Inspection Date 02/08/2018 Inspection Type Collection System Inspect Non Sampling Reason for Visit Routine Inspection Summary Page 2 Permit WQCSD0008 Owner - Facility Town of Saratoga Inspection Date 02/08/2018 Inspection Type Collection System Inspect Non Sampling Reason for Visit Routine Performance Standards Yes No NA NE Is Public Education Program for grease established and documented? ■ ❑ ❑ ❑ What educational tools are used? Mailings, two times per year Is Sewer Use Ordinance/Legal Authority available? ❑ ❑ ■ ❑ Does it appear that the Sewer Use Ordinance is enforced? ❑ ❑ ❑ Is Grease Trap Ordinance available? ❑ ❑ 1:10 Is Septic Tank Ordinance available (as applicable, i e annexation) ❑ ❑ 1:10 List enforcement actions by permittee, if any, in the last 12 months na Has an acceptable Capital Improvement Plan (CIP) been implemented? ❑ ❑ i ❑ Does CIP address short term needs and long term \"master plan\" concepts? ❑ ❑ E ❑ Does CIP cover three to five year period? ❑ ❑ 0 ❑ Does CIP include Goal Statement? ❑ ❑ E ❑ Does CIP include description of project area? ❑ ❑ ® ❑ Does CIP include description of existing facilities? ❑ ❑ N ❑ Does CIP include known deficiencies? ❑ ❑ ® ❑ Does CIP include forecasted future needs? ❑ ❑ ® ❑ Is CIP designated only for wastewater collection and treatment? ❑ ❑ E ❑ Approximate capital improvement budget for collection system? Total annual revenue for wastewater collection and treatment? CIP Comments na Is system free of known points of bypass? E ❑ ❑ ❑ If no, describe type of bypass and location No points of bypass noted Is a 24-hour notification sign posted at ALL pump stations? ® ❑ ❑ ❑ # Does the sign include Instructions for notification? ® ❑ ❑ ❑ Pump station identifier? ® ❑ ❑ ❑ 24-hour contact numbers ® ❑ ❑ ❑ If no, list deficient pump stations None deficient in signage # Do ALL pump stations have an "auto polling" feature/SCADA? ❑ ® ❑ ❑ Number of pump stations 7 Number of pump stations that have SCADA 0 Number of pump stations that have simple telemetry 2 Page 3 ti abed ® ❑ ❑ ❑ ® ❑ ❑ ❑ ❑ ❑ ❑ 3N VN ON saA ❑ ® ❑ ❑ ❑ ® ❑ ❑ ❑ ❑ ❑ M ❑ ❑ ❑ ®❑❑❑ 1:11:1 ❑ ❑❑❑■ ❑❑❑0 ®❑❑❑ 3N VN ON sal. m ❑ ❑ ❑ 0 e,algellene spJoaaa 6wuealo wa;sls aJV 6/ou961awa ue;o;uana aq; ui algissaooell;uajjno s(em-;o-;q6u ajV aalgePene sleM-10-;q61i Jo; sp.1o3aj aoueua;uiew aJV e,(;ipgegaj dwnd ohm uoi;e;s dwnd goea jo; dwnd meds auo;seal;e ojeq; sl 6;uawdinba iGeipxne pue ti;awala; 'swaele bugoedsul e,;uewdinbe jaq;o pue sdwnd 6u1jeoi.gnl pue 6ugoadsul esanlen Ile 6u1SIOJ2xa pue 6ugoodsul 61enowaJ sugap pue 6umealo apis;no pue apisul apnloui s6ol uoi;e;s dwnd op e,;uawdinbe (gpue;s/(oua6iawa 6ugsa; jo; alnpagos aq; si;egM e,;uewdinba /gpue;sj (oue6jewa 6w;sa; ao; pou,e;uiew alnpagos a sl e_ajgepene;uawdlnbe jo; spjooei aoueua;wew aiV siseq jelrBei uo smalna1 oho e,seaje welgad pue s6ol suoi;eiado Q 'aoueua;uiew 'uogoadsui 6uim91AGJ ao; alnpagos aq; sl;egM 6seaje welgojd wja;-}jogs pa;uawnoop sseippe o; sueld aneq aoswadns aq; saoa e,siseq jelnbej e uo sNooq bol Ile mav�aa josmiadns sao❑ 6algepene sNooq bol Ile aiy s;uawailn aM aoueua;uI?JN'g uol;eja p Iuawwoo IDN ;uewwoo e,sq;uow xis;sel ui sawl A;uoud-gbiq;o suogoadsui ler sin uaaq aneq; seH 6seuq (;uoud-g6iq;o suoi;oadsui;uewnoop;eg; algepene SPJ009J aJV 6aeal;sel aqa ul sewe a;owaa;o uoi;enjasgo ue uaaq aJaq; seH # 6wa;s(s an;ua;o uoi;enjasgo lenuue ue;onpuoo o; wa;sfs e aneq noA oa # 6s;weldwoo uezi;io;uawnoop;eq; algepene spaooaJ aJV 6 (ep Cana pa;oadsui suoi;e;s dwnd paddinba fu;awala;fyQVoS-uou ejV 6)JaOM e aouo;seal;e pa;oadsul suoge;s dwnd paddinbe fi;awela; jo V(]VOS aaV e,suogoadsui uoi;e;s dwnd ;uawnoop;eq; algepene spooei ajy e elgepene sawl JaMas Jo; spjooaj aoueua;wew ajy suol;oa sub GJIS uo saojeJaua aneq anlJ a;8waj9j aiwls aneq suoge;s dwnd oMl Juawwoo sjo;ejaua6 aneq suoi;e;s dwnd uanas;o anis swaele 6uianp PH umol pue oho o; lleo euogd puss suoi;e;s dwnd oml aquosa4 e,pa;uawelcwi a;ep 'SGA ji # e,wei6oid la;uoo;ooi a aneq aeulujad aq; saoa # sauawaimbai;iwjad;aawjou op ;eq; suoi;e;s dwnd ;o jegwnN g swiele lensm pue appne (luo aneq;eq; suoge;s d_und;o jagwnN augnoa ;isin Jo; uOSeaZI 6ugdweS uoN joadsul wags (S uogoalloo adRl uot;oadsul SLOZ/8oZ0 a;ea uoi;oadsul ebo;ejes;o umol 41111oe3 - Jaumo 80004SC)DM ;iw18d Permit WQCSD0008 Owner - Facility Town of Saratoga Inspection Date 02/08/2018 Inspection Type Collection System Inspect Non Sampling Reason for Visit Routine Has at least 10% of system been cleaned annually? ❑ M El EJ What areas are scheduled for cleaning in the next 12 months? Town indicated no line cleaning is done because there have been no issues There is an agreement with the Town of Wilson to inspect lines using camera equipment Is a Spill Response Action Plan available? El ❑ M Does the plan include 24-hour contact numbers i ❑ El Response time ❑ ❑ 00 Equipment list and spare parts inventory ❑ ❑ 0 M Access to cleaning equipment ■ Access to construction crews, contractors, and/or engineers ❑ ❑ ® ❑ Source of emergency funds ® El R ❑ Site sanitation and cleanup materials ❑ El 0 Post-overflow/spill assessment ❑ ■ Is a Spill Response Action Plan available for all personnel? ■ F ❑ Is the spare parts inventory adequate? El ❑ ❑ Comment Operators and other staff have correct numbers to call If spell occurs ® ❑ R D Records Yes No NA NE Are adequate records of all SSOs, spills and complaints available? Are records of SSOs that are under the reportable threshold available? Do spill records indicate repeated overflows (2 or more in 12 months) at same location? 1:1 El 0 El If yes, is there a corrective action plan? ❑ ❑ ® ❑ Is a map of the system available? ® El R ❑ Does the map include Pipe sizes ® ❑ ❑ ❑ Pipe materials Pipe location ® 0 F-1 D Flow direction ® ❑ R D Approximate pipe age ® El F-1 El Number of service taps ® El 0 El Pump stations and capacity ® ❑ ❑ If no, what percent is complete? List any modifications and extensions that need to be added to the map None # Does the permittee have a copy of their permit? El El 1:1 Iff Comment Page 5