Loading...
HomeMy WebLinkAbout20180212_NC0025836_INSP1EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0025836 18/01/26 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Hot Springs WWTP Bridge St Hot Springs NC 28743 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 09:00AM 18/01/26 15/12/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Randy A Joseph/ORC/828-622-7591/ Other Facility Data 10:30AM 18/01/26 20/09/30 Name, Address of Responsible Official/Title/Phone and Fax Number Randy A Joseph,PO Box 218 Hot Springs NC 287430218//828-622-7591/Contacted Yes Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Daniel J Boss ARO WQ//828-296-4658/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: 72F3A06B-7FEF-48E8-838B-71A2633BAA6C 2/12/2018 2/12/2018 NPDES yr/mo/day 18/01/26 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On 1/26/2018, I (Daniel Boss) conducted an Compliance Evaluation Inspection at the Hot Springs WWTP. I met with Randy Joseph (ORC) at the facility. The bar screen rakings need to be better contained. Settleable solids in the aeration tank were at 89%. This is too high and some solids should be removed from the basin. The effluent weir plate is rusting and may need refurbishment. The weir box had a lot of algae/plant growth in it and definitely needed cleaning. Two of the sludge transfer lines were spouting water and mixed liquor up in the air. Randy said they were missing flaps that would keep the liquid directed in the tank. Those should be replaced. Two of the diffusers in the aeration basin appeared to not be working, as those areas showed no sign of aeration. The center well of the clarifier was clogged with solids. Randy said that the center well would get cleaned out by the pump truck. *2/8/2016* Randy says that 3600 gallons of solids have been pumped out of the aeration basins and the settleable solids level is down to 70%. NC0025836 17 (Cont.) Page#2 DocuSign Envelope ID: 72F3A06B-7FEF-48E8-838B-71A2633BAA6C Permit:NC0025836 Inspection Date:01/26/2018 Owner - Facility: Inspection Type: Hot Springs WWTP Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Process control is done rarely. Bar screen rags were not well contained.Comment: Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin’s surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/l) Page#3 DocuSign Envelope ID: 72F3A06B-7FEF-48E8-838B-71A2633BAA6C Permit:NC0025836 Inspection Date:01/26/2018 Owner - Facility: Inspection Type: Hot Springs WWTP Compliance Evaluation Aeration Basins Yes No NA NE Not all of the diffusers are operational. Two of the diffusers appeared to not be working.Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately ¼ of the sidewall depth) Sludge blanket was 3' of 11' swd. Center well was full of floating solids.Comment: Disinfection-Liquid Yes No NA NE Is there adequate reserve supply of disinfectant? (Sodium Hypochlorite) Is pump feed system operational? Is bulk storage tank containment area adequate? (free of leaks/open drains) Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de-chlorination? Comment: De-chlorination Yes No NA NE Type of system ?Liquid Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de-chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de-chlorinators operational? Page#4 DocuSign Envelope ID: 72F3A06B-7FEF-48E8-838B-71A2633BAA6C Permit:NC0025836 Inspection Date:01/26/2018 Owner - Facility: Inspection Type: Hot Springs WWTP Compliance Evaluation De-chlorination Yes No NA NE Number of tubes in use? Liquid dechlorination feed is not proportional to the liquid chlorine feed because chlorine tablets are also used. Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Effluent pipe is under water.Comment: Page#5 DocuSign Envelope ID: 72F3A06B-7FEF-48E8-838B-71A2633BAA6C