Loading...
HomeMy WebLinkAbout20180209_NC0069892_INSPEPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0069892 17/01/29 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Andrews WTP Holland Farm Rd NCSR 1385 Andrews NC 28901 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 10:30AM 17/01/29 14/07/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Christopher Michael Ladd/ORC/828-360-6404/ Other Facility Data 11:45AM 17/01/29 17/08/31 Name, Address of Responsible Official/Title/Phone and Fax Number Bill Bailey,PO Box 1210 Andrews NC 28901//828-321-3126/Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenance Records/Reports Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Daniel J Boss ARO WQ//828-296-4658/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: DD2CCC77-8188-475C-9BF1-1B2912C3D27C 2/9/2018 2/9/2018 NPDES yr/mo/day 17/01/29 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On 1/29/2018, I (Daniel Boss) conducted a Compliance Evaluation Inspection of Andrews WTP wastewater treatment facility. Backup WWTP ORC Christopher Ladd was not available and so I did the inspection with Bill Bateman who is the WTP ORC. The pH levels in the clarifiers and outfall were all high, right at 9.0 su. This is within compliance but just barely. Mr. Bateman said that the clarifiers are planned to be pumped at 8-10 year intervals. Given that one of the clarifiers had an upset a couple years ago and released solids, it may be wise to pump solids out of the clarifiers more frequently. The effluent pipe was submerged. There were strange growths/deposits in the receiving channel. I assume that is due to fluctuating pH level of the effluent. The dechlorination system has not been needed to meet effluent permit limits for chlorine, according to Mr. Bateman. This system did not have the chemicals needed to operate it on site, but he said that he could have the necessary chemicals delivered on the same business day as needed. NC0069892 17 (Cont.) Page#2 DocuSign Envelope ID: DD2CCC77-8188-475C-9BF1-1B2912C3D27C Permit:NC0069892 Inspection Date:01/29/2017 Owner - Facility: Inspection Type: Andrews WTP Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Effluent pipe was under water. Strange growths/deposits in the receiving waters.Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately ¼ of the sidewall depth) South clarifier has never had solids pumped out. North clarifier had solids pumped out about a year ago. Comment: Page#3 DocuSign Envelope ID: DD2CCC77-8188-475C-9BF1-1B2912C3D27C Permit:NC0069892 Inspection Date:01/29/2017 Owner - Facility: Inspection Type: Andrews WTP Compliance Evaluation Secondary Clarifier Yes No NA NE De-chlorination Yes No NA NE Type of system ?Liquid Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de-chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de-chlorinators operational? Number of tubes in use? Dechlorination system is not in use. Mr. Bateman said they can have dechlorination chemicals on site the same day if needed. Comment: Page#4 DocuSign Envelope ID: DD2CCC77-8188-475C-9BF1-1B2912C3D27C