Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NC0024201_Compliance Evaluation Inspection_20180205
Water Resources ENVIRONMENTAL QUALITY February 5, 2018 R. Daiueley Brown, CEO Roanoke Rapids Sanitary District PO Box 308 Roanoke Rapids, North Carolina 27870 Subject - Dear Mr. Brown - ROY COOPER L , 1 NUCHAE -L S REGAN `, „rr LINDA CULPEPPER RECEI ED/DENR ®WR FEB 0, i 2018 Water Resources Permitting Section Compliance Evaluation Inspection Roanoke River Waste Treatment Plant NPDES Permit No NCO024201 Halifax County On January 23, 2018, Jason Robinson of the Raleigh Regional Office (RRO) conducted a compliance evaluation inspection of the subject facility. The assistance provided by Mr Steven Ellis, Operator in Responsible Charge (ORC) and Isabelle Field-Wilcoxon, Lab Supervisor was appreciated The inspection report is attached. The following observations were made - The facility is currently pennitted to discharge up to 8 34 MGD into Roanoke River, a class -C water in the Roanoke River Basin The facility's monthly average flow for the 2017 calendar year was approximately 3 0 MGD. The current pen -nit expired on March 31, 2017. A renewal application was received in September 2016 2 The plant is classified as a WW -4 wastewater facility. Mr Steven Ellis is designated as the primary Operator in Responsible Charge (ORC), and is a WW -4. Mr Timothy Skipper is designated as the main backup Operator (bORC) and is also a WW -4 Daily operation log books are detailed and are kept on-site going back at least three years The laboratory was inspected in a cursory manner The facility analyzes BOD, COD, TSS, Fecal Coliform ammonia nitrogen and total phosphorus, and is field certified for TRC, pH, Temperature and DO (Certification #70) Log books were kept and showed that incubators are kept at acceptable temperatures. pH buffers were within dates. Calibration logs were present All other parameters are analyzed by Mentech, Inc Lab results, chain -of -custody forms, and DMRs were complete and organized. September DMR data was compared to lab bench sheets; no data transcription errors were noted Samples were observed to be kept at proper temperature 4. The permit lists the following units ® Automatic and manual bar screens © Vortex Grit Removal • Influent Pump Station — Four Pumps o Two 375,000 Gallon Equalization Tanks (Formerly Clarifiers) Division of Water Resources, Raleigh Regional Office, Water Quality Operations Section www ncwaterquality org 1628 Mail Service Center, Raleigh, NC 27699-1628 Phone (919) 791-4200 Location 3800 Barrett Drive, Raleigh, NC 27609 Fax (919) 788-7159 • Manual Acid feed system (not used) • Two Primary Clarifiers (Typically only one is in operation) • Two Trickling Filters (Both were operating) • Three 2,000,000 Gallon Rectangular Secondary Clarifiers w/ Traveling Bridge (Typically two are in operation) • Three 500,000 aeration basins (Typically two are in operation) • Two Chlorine Contact Chambers (Typically onw is in operation) • Two RAS Pump Stations • Three anaerobic digesters with heat exchangers • One WAS Pump Station • Two Gravity Settling Tanks with Gravity Belt Thickener • 1,000,000 Gallons Solids Storage tank • Effluent Pump Station • Fourteen Sludge Drying Beds • On -Site Generator 5 The right of way to the outfall was properly maintained The effluent appeared clear and free of solids. There were no visible detrimental impacts to the receiving stream This facility was found to be compliant with NPDES permit conditions as a result of this inspection The plant is well maintained and documentation was found to be detailed, organized, and complete If you have any questions regarding the attached reports or any of the findings, please contact Jason Robinson at (919) 791-4200 (or email. Jason t.robinsonamncdeiu• gov). Sincerely, Danny Sinith Regional Supervisor Raleigh Regional Office ATTACHMENTS Compliance Inspection Report Cc Central Files w/attaclunent Raleigh Regional Office w/attachinent United States Environmental Protection Agency Form Approved EPA Washington D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A National Data System Coding (I e , PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 15 I 3 I NCO024201 111 12 I 18/01/23 I17 18 ICI 19 1 s 1 201 I 21111111 1111111111111111111111111 11111111111 f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA -------------Reserved--------- 67 70 71 I_ 72 I I 73 I I 174 7511 I I I 1 I 1 180 I I I I I Section 8 Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 0100PM 18/01!23 13/04/01 Roanoke River WWTP Exit Time/Date Permit Expiration Date 135 Aqueduct Rd Weldon NC 27890 03 OOPM 18/01/23 17/03/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Steven Lee Ellis/ORC/252-536-4884/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Gregg Camp,PO Box 308 Roanoke Rapids NC 278701/252-536-4884/ Yes Section C Areas Evaluated During Inspection (Check only those areas evaluated) ® Permit ® Flow Measurement ® Operations & Maintenance ® Records/Reports ® Sludge Handling Disposal ® Effluent/Receiving Waters ® Laboratory Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Jason T Robinso a RRO WQ/// gg 1 �9 GG Signa re of Manage me trQ A ReV,/ ewer Agency/Office/Phone andFaxx Numbers�� Date Al �'.,�to, { J/ /a1. ! _ /,� i' lfrld✓!f ' i�/� ,��i / 9 EPA Form35Fd 3 (Rev 9-94) Previous'edltions are obsolete , v Page# NPD=S yr/mo/day Inspection Type (Cont ) 31 NCO024201 111 121 18/01/23 117 18 I C i Section D Summary of Finding/Comments (At_ach additional sheets of narrative and checklists as necessary) 1 The facility is currently permitted to discharge up to 8 34 MGD Into Roanoke River, a class -C water in the Roanoke River Basin The facilitys monthly average flow for the 2017 calendar year was approximately 3 0 MGD The current permit expired on March 31, 2017 A renewal application was received in September 2016 2 The plant is classified as a WW -4 wastewater facility Mr Steven Ellis is designated as the primary Operator in Responsible Charge (ORC), and is a WW -4 Mr Timothy Skipper is designated as the main backup Operator (bORC) and is also a WW -4 Daily operation log books are detailed and are kept on-site going back at least three years 3 The laboratory was inspected In a cursory manner The facility analyzes BOD, COD, TSS, Fecal Coliform ammonia nitrogen and total phosphorus, and is field certified for TRC, pH, Temperature and DO (Certification #70) Log books were kept and showed that incubators are kept at acceptable temperatures pH buffers were within dates Calibration logs were present All other parameters are analyzed by Mentech, Inc Lab results, chain-of-c,astody forms, and DMRs were complete and organized September DMR data was compares to lab bench sheets, no data transcription errors were noted Samples were observed to be kept at proper temperature 4 The permit lists the following units Automatic and manual bar screens Vortex Grit Removal Influent Pump Station Four Pumps Two 375,000 Gallon Equalization Tanks (Formerly Clarifiers) Manual Acid feed system (not used) Two Primary Clarifiers (Typically only one is in operation) Two Trickling Filters (Both were operating) Three 2,000,000 Gallon Rectangular Secondary Clarifiers w/ Traveling Bridge (Typically two are in operation) Three 500,000 aeration basins (Typically two are in operation) Two Chlorine Contact Chambers (Typically onw is in operation) Two RAS Pump Stations Three anaerobic digesters with heat exchangers One WAS Pump Station Two Gravity Settling Tanks with Gravity Bel: Thickener 1,000,000 Gallons Solids Storage tank Effluent Pump Station Fourteen Sludge Drying Beds On -Site Generator 5 The right of way to the outfall was properly maintained The effluent appeared clear and free of solids There were no visible detrimental impacts to the receiving stream This facility was found to be compliant with NPDES permit conditions as a result of the inspection The plant Is well maintained and documentation was found to be detailed, organized, and complete Page# Permit NCO024201 Owner - Facility Roanoke River wwTP Inspection Date 01/23/2018 Inspection Type Compliance Evaluation Yes No NA NE (If the present permit expires in 6 months or less) Has the permittee submitted a new ® ❑ Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? i ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? ■ ❑ ❑ ❑ # Is the facility using a contract lab? M ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6 0 degrees M ❑ ❑ ❑ Celsius)? ® ❑ ❑ ❑ Incubator (Fecal Coliform) set to 44 5 degrees Celsius+/- 0 2 degrees? ■ ❑ ❑ ❑ Incubator (BOD) set to 20 0 degrees Celsius +/- 1 0 degrees? M ❑ ❑ ❑ Comment Facilitly anavlizes BOD, COD , TSS, Fecal Coliform, Ammonia Nltroaen Total Phosporus, Field certifed for TRC, pH, Temperature and DO Merritech is contract lab Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? M ❑ ❑ ❑ Does the facility analyze process control parameters, for ex MLSS, MCRT, Settleable M ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment Permit Yes No NA NE (If the present permit expires in 6 months or less) Has the permittee submitted a new ® ❑ ❑ ❑ application? 19 ❑ ❑ ❑ Is the facility as described in the permit? ® ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ® ❑ ❑ Is access to the plant site restricted to the general public? ® ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ® ❑ ❑ ❑ Comment Permit expired on March 31, 2017 Renweal application received in September 2016 Permit has not been issued yet Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 9 ❑ ❑ ❑ Is all required information readily available, complete and current? 19 ❑ ❑ ❑ Are all records maintained for 3 years (lab reg required 5 years)? K ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? M ❑ ❑ ❑ Is the chain -of -custody complete? IN ❑ ❑ ❑ Dates, times and location of sampling ❑ Name of individual performing the sampling ❑ Page# 3 Permit NCO024201 Owner - Facility Roanoke River VWJTP Yes No NA NE Mode cf operation Ext Air a Manual Inspection Date 01/23/2018 Inspection Type Compliance Evaluation Type o- aeration system Diffused Are the bars adequately screening debris? IM ❑ ❑ ❑ Record Keeping Yes No NA NE Results of analysis and calibration ❑ Are su-face aerators and mixers operational? ❑ ❑ ❑ Dates of analysis ❑ ❑ ❑ ❑ ❑ Name of person performing analyses ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? Transported CDCs ❑ ❑ Is the DO level acceptable? ❑ ❑ Are DMRs complete do they Include all permit parameters? ® ❑ ❑ ❑ Has the facility submitted Its annual compliance repert to users and DVVQ? ® ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ® ❑ ❑ ❑ on each shift? Is the ORC visitation log available and current? ® ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ® ❑ ❑ ❑ Is the backup operator certified at one grade less o- greater than the facility classification? ® ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? ® ❑ ❑ ❑ Facility -las copy of previous year's Annual Report on file for review? ® ❑ ❑ ❑ Comment Aeration Basins Yes No NA NE Mode cf operation Ext Air a Manual Type o- aeration system Diffused Are the bars adequately screening debris? IM ❑ ❑ ❑ Is the basin free of dead spots? N ❑ ❑ ❑ Are su-face aerators and mixers operational? ❑ ❑ ❑ Are the diffusers operational? ❑ ❑ ❑ ❑ Is the -oam the proper color for the treatment process? E ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? M ❑ ❑ ❑ Is the DO level acceptable? ❑ ❑ ❑ Is the DO level acceptable?(1 0 to 3 0 mg/1) ❑ ❑ ❑ Comment Bar Screens Yes No NA NE Type of bar screen a Manual b Mechanical Are the bars adequately screening debris? IM ❑ ❑ ❑ Is the screen free of excessive debris? W ❑ ❑ ❑ Page# 4 Permit NC0024201 Owner -Facility Roanoke River1ANVrP Inspection Date 01/23/2018 Inspection Type Compliance Evaluation Bar Screens Yes No NA NE Is disposal of screening in compliance? ■ ❑ 0 Is the unit in good condition? 0 ❑ ❑ ❑ Comment Grit Removal Yes No NA NE Type of grit removal ® ® D El a Manual ® El F F] b Mechanical ® ❑ 0 ❑ Is the grit free of excessive organic matter? ® El 0 C1 Is the grit free of excessive odor? ® ❑ ❑ ❑ # Is disposal of grit in compliance? ® D El Comment ® El ❑ ❑ Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? ® ® D El Is the wet well free of excessive grease? ® El F F] Are all pumps present? ® ❑ 0 ❑ Are all pumps operable? ® ❑ 0 C1 Are float controls operable? ® ❑ D ❑ Is SCADA telemetry available and operational? ® 0 ❑ Is audible and visual alarm available and operational? ® El ❑ ❑ Comment Equalization Basins Yes No NA NE Is the basin aerated? ® F-1 El Is the basin free of bypass lines or structures to the natural environment? El F-1 F] Is the basin free of excessive grease? EJ El El H Are all pumps present? El ❑ Ll C1 Are all pumps operable? El ❑ El 11 Are float controls operable? E] ❑ Are audible and visual alarms operable? El 0 El N # Is basin size/volume adequate? El ❑ El 11 Comment Page# 5 Permit NC0024201 Owner - Facility Inspection Date 01/23/2018 Inspection Type Roanoke River VWN/TP Compliance Evaluation Is the clarifier free of black and odorous wastewater? ® ❑ Primary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? ■ ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? ■ ❑ ❑ ❑ Are weirs level? ■ ❑ ❑ ❑ Is the site free of weir blockage? ® ❑ ❑ ❑ Is the site free of evidence of short-circuiting? ® ❑ ❑ ❑ Is scum removal adequate? ■ ❑ ❑ ❑ Is the site free of excessive floating sludge? ■ ❑ ❑ ❑ Is the drive unit operational? ■ ❑ ❑ ❑ Is the sludge blanket level acceptable? 0 ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately '/4 of the sidewall depth) ® ❑ ❑ ❑ Comment Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? ® ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? ® ❑ ❑ ❑ Are weirs level? ® ❑ ❑ ❑ Is the site free of weir blockage? ® ❑ ❑ ❑ Is the site free of evidence of short-circuiting? ® ❑ ❑ ❑ Is scum removal adequate? ® ❑ ❑ ❑ Is the site free of excessive floating sludge? ® ❑ ❑ ❑ Is the drive unit operational? M ❑ ❑ ❑ Is the return rate acceptable (low turbulence)? IM ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? 19 ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately 1/4 of the sidewall depth) IN ❑ ❑ ❑ Comment Trickling Filter Yes No NA NE Is the filter free of ponding? 51 ❑ ❑ ❑ Is the filter free of leaks at the center column of filter's distribution arms? M ❑ ❑ ❑ Is the distribution of flow even from the distribution arms? 9 ❑ ❑ ❑ Is the filter free of uneven or discolored growth? 0 ❑ ❑ ❑ Is the filter free of sloughing of excessive growth? M ❑ ❑ ❑ Are the filter's distribution arms orifices free of clogging? N ❑ ❑ ❑ Page# 6 Permit NCO024201 Owner - Facility Roanoke River WWTP Inspection Date 01/23/2018 Inspection Type Compliance Evaluation Trickling Filter Yes No NA NE Is the filter free of excessive filter flies, worms or snails? 0 ❑ ❑ ❑ Comment Chemical Feed Yes No NA NE Is containment adequate? 0 ❑ ❑ ❑ Is storage adequate? 0 ❑ ❑ ❑ Are backup pumps available? 0 ❑ ❑ ❑ Is the site free of excessive leaking? 0 ❑ ❑ ❑ Comment Solids Handling Equipment Yes No NA NE Is the equipment operational? 0 ❑ ❑ ❑ Is the chemical feed equipment operational? 0 ❑ ❑ ❑ Is storage adequate? 0 ❑ ❑ ❑ Is the site free of high level of solids In filtrate from filter presses or vacuum filters? 0 ❑ ❑ ❑ Is the site free of sludge buildup on belts and/or rollers of filter press? 0 ❑ ❑ ❑ Is the site free of excessive moisture in belt filter press sludge cake? 0 ❑ ❑ ❑ The facility has an approved sludge management plan? 0 ❑ ❑ ❑ Comment Drying Beds Yes No NA NE Is there adequate drying bed space? ® ❑ ❑ ❑ Is the sludge distribution on drying beds appropriate? ® ❑ ❑ ❑ Are the drying beds free of vegetation? ® ❑ ❑ ❑ # Is the site free of dry sludge remaining in beds? ® ❑ ❑ ❑ Is the site free of stockpiled sludge? ® ❑ ❑ ❑ Is the filtrate from sludge drying beds returned to the front of the plant? ® ❑ ❑ ❑ # Is the sludge disposed of through county landfill? ® ❑ ❑ ❑ # Is the sludge land applied? M ❑ ❑ ❑ (Vacuum filters) Is polymer mixing adequate? ❑ ❑ ❑ 19 Comment Standby Power Yes No NA NE Page# 7 Permit NCO024201 Owner - Facility Roanoke River WWTP Inspection Date 01/23/2018 Inspection Type Compliance Evaluation Yes No NA NE Are pumps In place? ® ❑ Standby Power Yes No NA NE Is automatically activated standby power available? 0 ❑ ❑ ❑ Is the generator tested by Interrupting primary power source? ® ❑ ❑ ❑ Is the generator tested under load? i ❑ ❑ ❑ Was generator tested-& operational during the inspe--tion? ❑ ® ❑ ❑ - - Do the generator(s) have adequate capacity to operate the entire wastewater site? ® ❑ ❑ ❑ Is there an emergency agreement with a fuel vendor for extended run on back-up power? ® ❑ ❑ ❑ Is the generator fuel level monitored? ® ❑ ❑ ❑ Comment - Pumps -RAS -WAS Yes No NA NE Are pumps In place? ® ❑ ❑ ❑ Are pumps operational? ® ❑ ❑ ❑ Are there adequate spare parts and supplies on site? ® ❑ ❑ ❑ Comment Disinfection -Liquid Yes No NA NE Is there adequate reserve supply of disinfectant? ® ❑ ❑ ❑ (Sodium Hypochlorite) Is pump feed system opera_Ional? ® ❑ ❑ ❑ Is bulk storage tank containment area adequate? (free of leaks/open drains) ® ❑ ❑ ❑ Is the level of chlorine residual acceptable? ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? M ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? ff ❑ ❑ ❑ Comment De -chlorination Yes No NA NE Type of system ? Liquid Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ ❑ Is storage appropriate for cylinders? 51 ❑ ❑ ❑ # Is de -chlorination substance stored away from chlorine containers? M ❑ ❑ ❑ Comment Are t -ie tablets the proper size and type? ❑ ❑ ❑ ❑ Are tablet de -chlorinators operational? ❑ ❑ ❑ ❑ Number of tubes In use? Page# 8 Permit NC0024201 Inspection Date 01/23/2018 De -chlorination Comment Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? Owner -Facility Roanoke River VWVrP Inspection Type Compliance Evaluation (If units are separated) Does the chart recorder match the flow meter? Comment Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment Yes No NA NE Yes No NA NE N ❑ ❑ ❑ * ❑ ❑ ❑ * ❑ ❑ ❑ * ❑ ❑ ❑ Yes No NA NE H ❑ ❑ ❑ 0 ❑ ❑ ❑ ❑ ❑ ® ❑ Page# 9