Loading...
HomeMy WebLinkAbout20161153 Ver 1_ Stormwater plan_20180119C007 stimmel LAINDMAPE ARCHITECTURE CIVIL ENGINEERING LAND PLANNING HANKINS - VILLAGE POINT 'ROJECI SQUARE CD'S 15-226 SUBJECT Clemmons Town Center Approved Stormwater Plans 'URPOSE For your use and distribution FROM Transmittal DATE 1/19/2018 FRANSMITTALI[ 00025 VIA: Info Exchange NAME COMPANY EMAIL I PHONE Kelway Howard Stimmel Associates, P.A. KHoward@stimmelpa.com 336-723-1067 TO NAME COMPANY I EMAIL IPHONE Sue Homewood NCDENR W -S Regional Office sue.homewood@ncdenr.gov (336) 776-9693 Sue, Brad Luckey asked that we send you these plans. Let us know if you REMARKS need anything further. Kelway DESCRIPTION OF CONTENTS QTY DATED TITLE NOTES 1 1/10/2018 15-226 C-5.5 POND SPEC IFICATIONS.pdf 15-226 C-5.0 OVERALL SWM.pdf 15-226 C-5.1 POND PLAN.pdf 1 3/28/2017 1 9/28/2017 1 3/28/2017 15-226 C-5.2 POND PROFILES.pdf 1 3/28/2017 15-226 C-5.3 POND DETAILS.pdf 1 3/28/2017 15-226 C-5.4 POND DETAILS.pdf 1/19/2018 Clemmons Town Center (8).pdf 1 COPIES Brad Luckey (Pilot Environmental, Inc) Steven Hankins (Hankins Companies, LLC) 0-1 1; LO L0 N N a 0 N N A x �x ( OFFSITE SIDEWALKS U N MANAGED PIN # 5883-95-4762 GIBRALTAR COMMERCIAL IV LLC. D.B. 3071 PG. 1035 PB. 47 PG. 120 CLEMMONS VILLAGE PHASE 1 CLEMMONS TOWN CENTER LLC • PHASE II _ SECOND REVISION OPOND DRAINAGE LI M ITS (TYP) ^ C-2 O � M ELM all ®w►�-::-L=. POND DRAINAGE 1 I I L M ITS (TYP) PIN #5883-95' 65 .00 PIN # 58$3 ���-7564.00 '' GIBRALTAR COMMERCIAL IV LLC. GIBRALTAR COMMERCIAL IV LLC. , I ''' D.B. 3071 PG. 1035 I I I TRACT 26 PB. 47 PG. 120 " D.B. 3071 PG. 1035 TRACT 2A PB. 47 PG. 120 I I I �z ADDITIONAL PARKING AREA: 9,148 SF (0.21 AC) / I I B.U.A.: 5,227 SF (0.12 AC) I \ / - - Z 1 W (57.14%) Un I DAIRI-0 i / SITE AREA: 76,709 SF 1.761 AC B.U.A.: 50,137 SF (1.151 AC) I I I �i (65.36%) I I I I �� 3 �j� PIN #5883-95-94 _2nAIPIQ II �i a1g, MEMO &A 1D.B. 3183 • G. 3842 M. J i owd O�0° T r� \ll f/.' \ ROADS \_ _ ��` / ..:.::..: ....•'''►•'"00 so / �^ I ° T ° Fti `� I ��� db AREA: 59,242 SF (1.36 AC) --� 3 ::.:..... / T �� FUTURE HOTEL SITE ,: �' `� ; \.�•;, \ `.•_ ( ) ...J ASSUMED IMPERVIOUS B.U.A.: 41,382 SF 0.95 AC o 0� FROM BACK OF CURB TO '.° .::': ' :.': (69.850 1 °� BACK OF CURB ON ALL o o SIDES THE SITE AND I �P ` �''• / / / X fog TBM CHISLED � ( I� I SSM \ �OOo O� 0 INCLUDED IN THE SITE y \ / ;� ) SQU90 ARE IN CURB , °Oo 0 I ` BUA TOTAL. 0 N\ O O m I I l I ° O 310' STREAM \ J ✓ , , I FFEIR I 3 lI l -05- _-5; 5893 13 6 NEWBRIDGE BANK �100' STREAM onPOND ACCESS ROAD BUFFER DB. 2122 PG. 2869 J I U I y w I LD o I \ v I � I I / � < �►� FNM � ��. : r: �' 4• I � •. P •5.4 / - I O I' 0 O 1 I - I a IO SITE � � c� I � 111 _ •� :�.`� - I• I I I I -Z o Ooo � °� ° o °°°o< � / - / "' \_,� /� _-�;� • �,.� SITE AREA: 710,636.1 SF (16.314 AC) f I � I STORMWATER MANAGEMENT NOTES EXISTING B.U.A. REMOVED. 23,096 SF (0.53 AC)O 0 \\ PROPOSED B.U.A.: 327,094 SF (7.51 AC)I \ 1. DISTURBED AREA: 739,213 SF (16.97 AC, INCLUDES OFFSITE) W WATERSHED: LOWER YADKIN WS -IV, 70% MAX B.U.A. . 0 / j "?,h. INCREASE IN B.U.A: 313,998 SF (7.21 AC) z I I PIN 58 - 4-298 -- L�I a / ° Z' O O / r �Q \ FLOOD PLAIN: NONE II ^ O°O WO O O // �;' (46.03%) J LUIHN FOUR INC _ o , SITE DRAIN TO 303(d) STREAM: NO I 0° 1 DB. 2449 PG.1340 _ I SITE AREA: 710,636 SF (16.31 AC) 1 O0 ° ° - ° �' � � . / TOTAL POND DRAINAGE AREA: 765,287 SF 17.57 AC l , O ° ° O 0 1 > / /;;•+: PIN # 5883=94-49 2 I \ JJh PREDEVELOPED CONDITIONS: O O / � r'.• / :,.� . ;• ��� � I VILLAGE POINT LLC. 7 � �� � '1 EXISTING ON-SITE BUA= 23,087 SF 0.53 AC / �° ° ° I \ PART OF D.B. 2534 PG. 4440 1 L _ -- l� -,1 EXISTING BUA REMOVED= 23,087 SF (0.53 AC� O I / ,� `:y z ' I NET REMAINING BUA= 0 SF (0.0 AC) ° o / / ZONED PB -S l / O °� O � r_ •x, �.� W POST DEVELOPED CONDITIONS: 710,636.1 Sq. Feet W 'r 1 EXISTING ON-SITE BUA= 0 SF (0.0 AC) 16.314 Acres \ PROPOSED NEW SITE BUA= 327,106 SF (7.51 AC) ,I \ �P DAIRI-0 BUA= 50,137 SF 1.15 AC j/ - ( ) ROADS BUA- 41,382 SF (0.95 AC) PARKING ADDITION BUA= 5,227 SF (0.12 AC) °O°�� O ° / �O �� .,'� • , II �/ PARCEL 1 BUA= 45,736SF 1.05 AC PARCEL 2 BUA= 41,076 SF 0.94 AC __✓ POND BUA= 22,200 SF 0.51 AC� 0 0 ° ° / J / < ( z 1 \ OFFSITE SIDEWALKS ON JESSE LANE= ,042 SF 0.02 AC) _ c / ° �j° O ° O ;.. •'�, / / \ y TOTAL BUA= 533,906 SF (12.25 AC) / O O I I �� •� I I � _- � �/ / �� 1 I PROPOSED BUA BYPASSING POND (WALKS)= 1,042 SF (0.02 AC) \ \ � 0 1 � � �__ _ ., • I .. 1 III _ _ � � o I I � o � C 1 O ° O � �• I I / � N /" P I IN NE I . .. - • LOAD��f7NE L6ADIN0 _ NE �1 I� � I PARCEL 1 SITE AREA: 65,693.9 SF (1.508 AC) PROPOSED B.U.A.: 45,736 SF (1.05 AC \ I o . I � 2 � / / / / / 00 ° PIN # 5893-04-2704 I I I I VILLAGE POINT LLC. I f I I 0 \ / /\ PART OF D.B. 2534 PG. 4440 J / P.B.62 PG.131 LOT 3 3 ' i ZONED PB -S 00� � 0 000 65,693.9 S Feet r 30 STREAM / . � i _ S q oo° ° BurrER I I ' Acres 0 �° ° °o �°0 0 �:: ,,. •, POND DRAINAGE � �, I 1.508.,,. I / <> A<_0 LIMITS (TYP) I I I I / o° ° PROPOSED WET o c DETENTION POND ><,> 00 �0 00 �< 0' ° ° °�30' STREAM 100' STREA PARCEL 2 / 0 0 O oo \ �� 680 SF (1.347 AC) � s j/ SITE AREA. 58, j o 0000 0 OO O O°OO OO BUFFER // / \ _ \� �� PROPOSED B.U.A.: 41,076 SF (0.94 AC) 0_0 O° 0° O O �° ° 100' STREAM L �/ �\LP / I (70%) / 00 O°'°° 0000000000 BUFFER /� / \ �� 3 ° L 0 o00Oo0 w°`.>P cO' '� v h� ° 0 O 0 ° o ///// \ \ \i \ P �• \ PIN # 5893-04-0489 ^Q 4,h/o�C Qc� �o Oo 0 0 0 ° o j �/� //� /� / / / I VILLAGE POINT LLC. / �// �- / I PART OF D.B. 2534 PG. 4440 �� P N 5883 9 5175 / /� ro I P.B. 62 PG.131, LOT 2 0 D.B. 3122 P.G. 3896 / 3 / b I ZONED PB -S ,` D.B. 3192 PG. 4328 \ 58,680.0 Sq. Feet / /��✓j \� // 1.347 Acres CLEMMONS TOWN CENTER a /� T. P.B. 62A PG. EN39, ,LLCLOT 1 / \� r PH \ 41 / \ / `� \, \ INV. 815.14 / C / % \ L \ I PEACE HAVEN ROAD SITE VICINITY MAP KINNAMON ROAD North NOT TO SCALE Gj'pN MUST CO JNO U -r jT y PR TF�r T FC 'h J � � BEFORE YOU DIG! CALL 811 N.C. ONE -CALL CENTER IT'S THE LAW! SURVEY DISCLAIMER: NET BUA TO POND= 532,864 SF (12.23 AC) 2. A BLANKET EASEMENT WILL BE GRANTED TO ALLOW THE VILLAGE OF CLEMMONS ACCESS TO THE SITE FOR STORM DRAINAGE AND STORMWATER MANAGEMENT INSPECTIONS OR MAINTENANCE. 3. THE MAXIMUM IMPERVIOUS AREA ALLOWED FOR THE POND IS 532,864 SF. ANY ADDITIONAL IMPERVIOUS AREA OR DRAINAGE AREA WILL REQUIRE A REVISED. STORMWATER PERMIT. 4. THE POND SHALL HAVE FULL DESIGN VOLUME AT THE COMPLETION OF THE PROJECT. ANY SILT DUE TO CONSTRUCTION SHALL BE REMOVED PRIOR TO AS -BUILT. _ THE BOUNDARY AND TOPOGRAPHIC INFORMATION HEREIN IS FROM SURVEY INFORMATION SUPPLIED BY: SGROI LAND SURVEYING, PLLC 145 W. PARRIS AVE., SUITE 101 HIGH POINT, NC 27262 North 336-885-1366 ELEVATION DATUM IS NAVD88 I, Wilbur Christmas, P.E., to the best of my knowledge, certify that the permanent stormwater management control(s) shown on this plan has been designed in accordance with stormwater management quantity and stormwater management quality requirements of the Village of Clemmons and the State of North Carolina, as applicable. I also certify that other applicable local, state, and federal permits have been applied for and/or received. Check other permits applied for and/or received, if applicable X Erosion and Sediment Control permit (Winston-Salem/Forsyth County) Floodplain Development permit (Winston-Salem/Forsyth County) X 401 water quality certification (State of NC) X 404 permit for work in waters/wetlands of the US (US Army Corps of Engineers) Dam Safety permit (State of NC) X Other: specify here DAM HAZARD DETERMINATION Signature of licensed design professional4a/ "" t Date _3/27/17 STORMWATER NOTE: 1. THE GENERAL CONTRACTOR/DEVELOPER SHALL CONTACT THE STORMWATER ADMINISTRATOR FOR AN INSPECTION OF THE STORMWATER FEATURES PRIOR TO THE ISSUANCE OF THE STORMWATER MANAGEMENT OCCUPANCY PERMIT. 50 0 50 100 150 SCALE: 1" = 50' 4V 000011111111111:1P stimmel LANDSCAPE ARCHITECTURE CIVIL ENGINEERING LAND PLANNING 601 N. TRADE STREET, SUITE 200 WINSTON-SALEM, NC 27101 P: 336.723.1067 F: 336.723.1069 www.stimmelpa.com SEALS: NCBEES CERT. NO.: C-1347 SEAL r' - 23552 3-2'T,17;*vo - 111111110 - PROJECT: CLIENT: CLEMMONS TC, LLC 16501 NORTHCROSS DRIVE SUITE D HUNTERSVILLE, NC 28078-5040 DRAWN: CYNIC DATE: 1/31/2017 REVISIONS: ,3/27/2017 CITY/VILLAGE/OWNER COMMENTS JOB. NO: 15-226 SHEET TITLE: OVERALL STORMWATER MANAGEMENT PLAN SCALE: 111 =50' SHEET NO.: C�5mO © STIMMEL ASSOCIATES, P.A LO I 0 s 0) 0 3 a 0 I LO LL w,Ol 'j I prA ON IL m >v- RIP RAS OUTLET 7 �? I�w V �g5� /w w •�`�Tj K `ELEV. 79922.00..__..... I I a PROTECTIO �_ow NCDOT CLASS B w 1 y 15'L X 17'W W O \ . W .WWWWW, w WWWWwW WWWWW�W W J <-> �• ���w:��� �% v v 24" DIP NV: 775.75 J O / RETAINING WALL / (DESIGN BY OTHERS) %O O 4„ SOLID WALLED SCH. 40 PVC �' • N� (/ O PIPES DISCHAR E TO HEADWALL.30 O T — �O BUFFERTREAM �� / \ �� / /�/ �— •• L� / / I 1 /� C - � 100' STREAM � � - 30' STREAM O� BUFFER o O 100' STREAM BUFFER �� -- \ W WL INV IN 7 C14 PEACE HAVEN ROAD 0 O SITE VICINITY MAP NOTES IN ►►_X•►:7_l North NOT TO SCALE 1. SEE C-5.5 FOR NOTES AND SPECIFICATIONS FOR WET DETENTION PONDS. 2. SEASONAL HIGH WATER TABLE ELEVATION BASED ON A STUDY BY ECS CAROLINAS, LLC DATED 11/9/2016. 3. PLANTED SHELF SHALL BE INSTALLED AT THE END OF THE PROJECT AFTER ENTIRE DRAINAGE AREA IS STABILIZED WITH APPROVAL OF THE VILLAGE OF CLEMMONS. SEE SHEET L-1.2 PLANTING PLAN AND REQUIREMENTS. vJNAnnusr uTILIT Y PROTFC�oTo Q"2p'joGO�G J � � BEFORE YOU DIG! CALL 811 N.C. ONE -CALL CENTER IT'S THE LAW! THE BOUNDARY AND TOPOGRAPHIC INFORMATION HEREIN IS FROM SURVEY INFORMATION SUPPLIED BY: SGROI LAND SURVEYING, PLLC 145 W. PARRIS AVE., SUITE 101 HIGH POINT, NC 27262 336-885-1366 North ELEVATION DATUM IS NAVD88 20 0 20 40 60 SCALE: 1” = 20' stimmel LANDSCAPE ARCHITECTURE CIVIL ENGINEERING LAND PLANNING 601 N. TRADE STREET, SUITE 200 WINSTON-SALEM, NC 27101 P: 336.723.1067 F: 336.723.1069 www.stimmelpa.com SEALS: NCBEES CERT. NO.: C-1347 o 0 SEAL 23552 ' c'): PROJECT: z 0 (1) Z O" z U) �z 0 W � JW UJ U CLIENT: CLEMMONS TC, LLC 16501 NORTHCROSS DRIVE SUITE D HUNTERSVILLE, NC 28078-5040 DRAWN: CY,WC DATE: 1/31/2017 REVISIONS: 3/27/2017 CITY/VILLAGE/OWNER COMMENTS 4/28/2017 VILLAGE COMMENTS JOB. NO: 15-226 SHEET TITLE: WET DETENTION POND PLAN SCALE: 1 if =20' SHEET NO.: C-5.1 © STIMMEL ASSOCIATES, P.A. 810 805 800 795 790 785 780 775 770 820 815 810 805 800 795 790 785 780 775 770 765 0+00 NCDOT TYPE 2 0+50 1+0 1+50 GEOTEXTILE FABRIC UNDERLINER 4" SOLID WALLED SCH. 40 PVC. CUT MINIMUM 5'D X 10'W CORE TRENCH PROPOSED GRADE INTO RESIDUAL GROUND AS SHOWN ON SEE C-5.1 FOR DETAIL 2 THIS SHEET. PROPOSED GRADES 2+00 POND CROSS SECTION 2+50 SCALE: HORIZ. 1"=20' VERT. 1"=10' 3+00 3+50 820 815 810 805 800 795 790 85 780 775 770 765 3+95 15.15' NOTE: DOWNSTREAM SLOPE - a EXISTING a CONTRACTOR SHALL NOTI THE ENGINEER AND THE CLEAN NATURAL GRADE a. Q 4' X 4' I.D. CONCRETE RISER W/ MONOLITHINC BASE AND TESTING FIRM WHEN CORE TRENCH EXCAVATION IS SAND MEETING HOMOGENOUS DAM FILL - SEE SHEET BY OTHERS C-5.5 FOR MATERIAL AND TRASH RACK TRASH RACK. SEE DETAILS ON 100 R: 791.77 PLACEMENT SPECIFICATIONS SEE DETAILS ON SHEET C-5.3. - GRADATION SEE ; ..:....... SHEET C-5.4 SOILS. FAILURE TO DO NOTE 2 SEEPAGE DIAPHRAGM. 10' SO WILL RESULT IN CORE z 25 Y - 791.E EMERGENCY SPILLWAY SEE DETAILS THIS SHEET. / 10 YR: 791.26 10' PLANTED SHELF 125 LF 24" D.I.P. THICKNESS AM WP DAM ELEV. /94.UU \/4/TOP 2 YR: 790.98 0.5' ELEV. 792.00 CLASS 50 ® 1.0% ___________ EMERGENCY SPILLWAY ELEV. 792.00 RISER ELEV 1.00 ASTM C33 GRADATION (SEE NOTE 2 TOP OF DAM 13.6 , NCDOT STD. 838.01 � ELEV. 794.00 ... ..v.NORMAL POOL. ELEV. 788.00 _ .. ... _ .. ... _ .. � 24" RCP � ISTING GRADE-\ CONCRETE HEADWALL. BACKFILL 'S1 "= �� J (/� 6 PVC 6.5'.., / INV.: 784.5�� SEE DET. THIS SHEET. 5' MIN. l D.I. 65 W - NORMAL POOL INV.: 786.0 36 RCP PIPE S 788.00 0 FOREBAY EXISTING 10.0' PWO TOP OF 1' PERMANENT -... ... - ... -... ..-...-...-...-...-�--� INV.: 783.5 J GRADE 1-I 0 5' TY P: 5> SEDIMENT STORAGE: 778.00 5, 1.5. -0.5' MIN- 3' Fl .. -0.5' ...- 'T MIN, RENO MA ERESS ..,.... ..... 3' FILL INTO EXISTING SLOPE INVERT: 775.5 10' PLANTED SHELF 1' PSS SEE DETAIL THIS SHEET • CONCRETE PIPE CRADLE BOTTOM 2' HIGH CLASS B RIP -RAP 12" THICK CLAY POND LINER. NCDOT CLASS B RIP SEE DETAIL THIS SHEET DRAIN BERM AROUND RISER WITH 1' THICK INSTALL PER GEOTECHNICAL 10' MIN. AND A MINIMUM 2' CORE TRENCH SHALL BE WIDE RAP PAD SEE C-5.1 AREA: MONOLITHIC BASE LAYER OF NCDOT #57 STONE ON ENGINEERS RECOMMENDATIONS. SEE FOR DIMENSIONS • SLOT WIDTH = 0.01" UPSTREAM SIDE. SPECIFICAIONS ON C-5.5. INTO RESIDUAL SOIL. 0+00 NCDOT TYPE 2 0+50 1+0 1+50 GEOTEXTILE FABRIC UNDERLINER 4" SOLID WALLED SCH. 40 PVC. CUT MINIMUM 5'D X 10'W CORE TRENCH PROPOSED GRADE INTO RESIDUAL GROUND AS SHOWN ON SEE C-5.1 FOR DETAIL 2 THIS SHEET. PROPOSED GRADES 2+00 POND CROSS SECTION 2+50 SCALE: HORIZ. 1"=20' VERT. 1"=10' 3+00 3+50 820 815 810 805 800 795 790 85 780 775 770 765 3+95 -0+00 0+50 1+00 1+50 2+00 2+50 3+00 r;" DAM CENTERLINE PROFILE 15.15' NOTE: DOWNSTREAM SLOPE - a a CONTRACTOR SHALL NOTI THE ENGINEER AND THE CLEAN NATURAL RETAINING WALL a. Q TESTING FIRM WHEN CORE TRENCH EXCAVATION IS SAND MEETING ° BY OTHERS COMPLETE PRIOR TO PLACING CORE TRENCH FILL GRADATION SEE ; ..:....... FOR INSPECTION OF EXISTING SOILS. FAILURE TO DO NOTE 2 SO WILL RESULT IN CORE TRENCH BEING RE -EXCAVATED EMERGENCY SPILLWAY / CLEAN NATURAL SAND MEETING ... ELEV. 792.00 4MIN.: :... "TRENCH WIDTH ...•.,MIN. 4' '': -7777777- .. ,• .::. RETAINING WALL BY OTHERS ASTM C33 GRADATION (SEE NOTE 2 TOP OF DAM 13.6 , ELEV. 794.00 : E ISTING GRADE-\ 6.5'.., 24 D.I. 65 W - NORMAL POOL PIPE DAM FILL 788.00 • -...-...-...-... -... ... - ... -... ..-...-...-...-...-�--� --1 TS ��I -17 1-I 0 5' TY P: 1.5. -0.5' MIN- .. -0.5' ...- 'T MIN, C TF CORE PROPOSED DAM 3' FILL INTO EXISTING SLOPE DRAINAGE PIPE TO 5 MINIMUM CORE DEPTH E • SECTION A -A BE ON 4" SLOTTED SCH. 40 PVC WELL AND A MINIMUM 2' CORE TRENCH SHALL BE WIDE SCREEN PIPE IN DIAPHRAGM AREA: NOTE: • SLOT WIDTH = 0.01" INTO RESIDUAL SOIL. ENOUGH TO ACCOMMODATE • O.D. SLOT LENGTH = 1.75" 1. CONCRETE CRADLE NOT SHOWN ON THIS DETAIL FOR CLARITY. SEE • SLOT SPACING = 0.25" CONCRETE CRADLE DETAIL FOR INSTALLATION OF CRADLE. COMPACTION EQUIPMENT OR = 4 2. SAND USED FOR SEEPAGE DIAPHRAGM SHALL MEET ASTM C-33 GRADATION AND SHALL BE TO FIELD VERIFY. SAND MATERIALS AND ROCK SCREENINGS NOT ALLOWED. SEEPAGE 24" DIP -0+00 0+50 1+00 1+50 2+00 2+50 3+00 r;" DAM CENTERLINE PROFILE NOT TO SCALE 8' ° ° a a a : ° D a a a D ° ° . a 24" DI OUTLET BARREL 4' SEEPAGE a DIAPHRAGM a ° DRAIN PIPE D ° ° a a a a a a zfta a ° ° a ° ° RODENT GUARD <. a Q ° a ° a a ELEVATION CONCRETE HEADWALL 24" NCDOT CLASS B RIP RAP TOP OF RIPRAP • O.D. SLOT LENGTH = 1.75" • SLOT SPACING = 0.25" • ROWS OF SLOTS = 4 NCDOT STD. 838.01 CONCRETE HEADWALL �9 MODIFY TO EXTEND TO _ MIN. 4' BELOW OUTLET BARREL INVERT _ _ _ NCDOT TYPE' -2 GEOTEXTILE SCALE: HORIZ. 1"=20' VERT. 1"=10' 3+50 4+00 VEGETATED EMERGENCY SPILLWAY. ELEV: 792.00 SEE SHT. C-5.5 FOR SEEDING SPECIFICATIONS. LINE WITH NORTH AMERICAN GREEN P300 PERMANENT TURF REINFORCEMENT MAT. TOP DAM: 794.00 1 2 1 4 4 16 EMERGENCY SPILLWAY SECTION NTS CLASS B STONE SECTION THROUGH FOREBAY NTS ° CONCRETE 24" DI OUTLET PIPEHEADWALL .__D° ° (SEE PLANS) a D INV: 775.75 - - - - - - - 0 4" SCH 40 PVC ° ° ° SOLID PIPE �. a = _ - I 2'-1 ° ° a 0 a 4"DIAPHRAGM DRAIN PIPE 101 1" #0 0515 D 15.15' DOWNSTREAM SLOPE - a a CLEAN NATURAL a. Q SAND MEETING ° ASTM C33b. GRADATION SEE ; ..:....... NOTE 2 CLEAN NATURAL SAND MEETING ... 4MIN.: :... "TRENCH WIDTH ...•.,MIN. 4' '': -7777777- .. ,• .::. ASTM C33 GRADATION (SEE NOTE 2 13.6 , : F. 6.5'.., 24 D.I. 65 W - PIPE • • , 0 5' TY P: 1.5. -0.5' MIN- .. -0.5' ...- 'T MIN, C TF 3' DRAINAGE PIPE TO SECTION A -A BE ON 4" SLOTTED SCH. 40 PVC WELL BOTHAPPED ENDS SIDE VIEW SCREEN PIPE IN DIAPHRAGM AREA: NOTE: • SLOT WIDTH = 0.01" • O.D. SLOT LENGTH = 1.75" 1. CONCRETE CRADLE NOT SHOWN ON THIS DETAIL FOR CLARITY. SEE • SLOT SPACING = 0.25" CONCRETE CRADLE DETAIL FOR INSTALLATION OF CRADLE. • ROWS OF SLOTS = 4 2. SAND USED FOR SEEPAGE DIAPHRAGM SHALL MEET ASTM C-33 GRADATION AND SHALL BE "CLEAN NATURAL SAND." MANUFACTURED SAND MATERIALS AND ROCK SCREENINGS NOT ALLOWED. SEEPAGE DIAPHRAGM NOT TO SCALE 8' ° ° a a a : ° D a a a D ° ° . a 24" DI OUTLET BARREL 4' SEEPAGE a DIAPHRAGM a ° DRAIN PIPE D ° ° a a a a a a zfta a ° ° a ° ° RODENT GUARD <. a Q ° a ° a a ELEVATION CONCRETE HEADWALL 24" NCDOT CLASS B RIP RAP TOP OF RIPRAP • O.D. SLOT LENGTH = 1.75" • SLOT SPACING = 0.25" • ROWS OF SLOTS = 4 NCDOT STD. 838.01 CONCRETE HEADWALL �9 MODIFY TO EXTEND TO _ MIN. 4' BELOW OUTLET BARREL INVERT _ _ _ NCDOT TYPE' -2 GEOTEXTILE SCALE: HORIZ. 1"=20' VERT. 1"=10' 3+50 4+00 VEGETATED EMERGENCY SPILLWAY. ELEV: 792.00 SEE SHT. C-5.5 FOR SEEDING SPECIFICATIONS. LINE WITH NORTH AMERICAN GREEN P300 PERMANENT TURF REINFORCEMENT MAT. TOP DAM: 794.00 1 2 1 4 4 16 EMERGENCY SPILLWAY SECTION NTS CLASS B STONE SECTION THROUGH FOREBAY NTS ° CONCRETE 24" DI OUTLET PIPEHEADWALL .__D° ° (SEE PLANS) a D INV: 775.75 - - - - - - - 0 4" SCH 40 PVC ° ° ° SOLID PIPE �. a = _ - I 2'-1 ° ° a 0 a 4"DIAPHRAGM DRAIN PIPE 101 1" #0 0515 D EXPANDED ALUMINUM GRATE (4)-Y2"0 STAINLESS STEEL EXPANSION ANCHOR WITH 1" STAINLESS STEEL ° Q WASHERS 4 RODENT GUARD 4+50 RENO MATTRESS N.T.S. A" nIADLJDACAA 5+00 810 805 800 795 790 785 780 775 770 5+555 3 X PIPE DIAMETER 12 THICK RENO MATTRESS WITH NCDOT CLASS B STONE FILL WOVEN GEOTEXTILE FABRIC / MIRAFI 70OX OR EQUAL SECTION INSIDE EDGE OF VEGETATIVE SHELF NORMAL POOL ME WOVEN GEOTEXTILE FABRIC MIRAFI 70OX OR EQUAL PROFILE 12" THICK RENO MATTRESS WITH NCDOT CLASS B STONE FILL ,BOTTOM POND PIPE TRENCH _I- COMPACTED BACKFILL _:_j I - - CONCRETE CRADLE _ RISER OUTLET -_ PIPE (SEE PLANS) I= ad a Q -1 11. _ EH77 - I INITIAL POUR 171 1' MIN 1' MIN 6" MINIMUM. PROVIDE SOLID CONCRETE BLOCKING UNDER PIPE NOTES: 1. CONCRETE CRADLE MATERIAL SHALL BE 1,000 PSI PUMP MIX. 2. DO NOT FORM THE SIDES OF THE CRADLE - POUR FULL WIDTH OF TRENCH 3. PLACE CRADLE IN TWO POURS TO PREVENT PIPE FLOATATION. INITIAL POUR TO EXTEND 3" - 4" ABOVE UNDER SIDE OF PIPE. FINAL POUR TO EXTEND 3/4 PIPE DIAMETER. 4. VIBRATE CONCRETE TO INSURE NO VOIDS. 5. FORM ENDS OF CONC. CRADLE AT SEEPAGE DIAPHRAGM CONCRETE PIPE CRADLE N.T.S. N.T.S. stimmel LANDSCAPE ARCHITECTURE CIVIL ENGINEERING LAND PLANNING 601 N. TRADE STREET, SUITE 200 WINSTON-SALEM, NC 27101 P: 336.723.1067 F: 336.723.1069 www.stimmelpa.com SEALS: NCBEES CERT. NO.: C-1347 •``%N "CA"I1- -%S SEAL- 23552 ,4�, ........... I CLIENT: CLEMMONS TC, LLC 16501 NORTHCROSS DRIVE SUITE D HUNTERSVILLE, NC 28078-5040 DRAWN: CY,WC DATE: 1/31/2017 REVISIONS: 0 3/27/2017 CITY/VILLAGE/OWNER COMMENTS JOB. NO: 15-226 SHEET TITLE: WET DETENTION POND PROFILES AND DETAILS SCALE: AS NOTED SHEET NO.: �5 2 ■ ©STIMMEL ASSOCIATES, P.A. a � a a ° a. Q ° EXPANDED ALUMINUM GRATE (4)-Y2"0 STAINLESS STEEL EXPANSION ANCHOR WITH 1" STAINLESS STEEL ° Q WASHERS 4 RODENT GUARD 4+50 RENO MATTRESS N.T.S. A" nIADLJDACAA 5+00 810 805 800 795 790 785 780 775 770 5+555 3 X PIPE DIAMETER 12 THICK RENO MATTRESS WITH NCDOT CLASS B STONE FILL WOVEN GEOTEXTILE FABRIC / MIRAFI 70OX OR EQUAL SECTION INSIDE EDGE OF VEGETATIVE SHELF NORMAL POOL ME WOVEN GEOTEXTILE FABRIC MIRAFI 70OX OR EQUAL PROFILE 12" THICK RENO MATTRESS WITH NCDOT CLASS B STONE FILL ,BOTTOM POND PIPE TRENCH _I- COMPACTED BACKFILL _:_j I - - CONCRETE CRADLE _ RISER OUTLET -_ PIPE (SEE PLANS) I= ad a Q -1 11. _ EH77 - I INITIAL POUR 171 1' MIN 1' MIN 6" MINIMUM. PROVIDE SOLID CONCRETE BLOCKING UNDER PIPE NOTES: 1. CONCRETE CRADLE MATERIAL SHALL BE 1,000 PSI PUMP MIX. 2. DO NOT FORM THE SIDES OF THE CRADLE - POUR FULL WIDTH OF TRENCH 3. PLACE CRADLE IN TWO POURS TO PREVENT PIPE FLOATATION. INITIAL POUR TO EXTEND 3" - 4" ABOVE UNDER SIDE OF PIPE. FINAL POUR TO EXTEND 3/4 PIPE DIAMETER. 4. VIBRATE CONCRETE TO INSURE NO VOIDS. 5. FORM ENDS OF CONC. CRADLE AT SEEPAGE DIAPHRAGM CONCRETE PIPE CRADLE N.T.S. N.T.S. stimmel LANDSCAPE ARCHITECTURE CIVIL ENGINEERING LAND PLANNING 601 N. TRADE STREET, SUITE 200 WINSTON-SALEM, NC 27101 P: 336.723.1067 F: 336.723.1069 www.stimmelpa.com SEALS: NCBEES CERT. NO.: C-1347 •``%N "CA"I1- -%S SEAL- 23552 ,4�, ........... I CLIENT: CLEMMONS TC, LLC 16501 NORTHCROSS DRIVE SUITE D HUNTERSVILLE, NC 28078-5040 DRAWN: CY,WC DATE: 1/31/2017 REVISIONS: 0 3/27/2017 CITY/VILLAGE/OWNER COMMENTS JOB. NO: 15-226 SHEET TITLE: WET DETENTION POND PROFILES AND DETAILS SCALE: AS NOTED SHEET NO.: �5 2 ■ ©STIMMEL ASSOCIATES, P.A. NORMAL POOL ELEV. 788.00 54" BASE SECTION HEIGHT 12" 12 ELEV. 791.00 3000 PSI CONCRETE - COLLAR 12" Qd d. a 4„ Q. d e ° a . 22 1/4" ' d .(7777-- a 8" 24" DUCTILE IRON OUTLET PIPE MONOLITHINC BASE PRECAST STRUCTURE WALL 8" COAT SURFACE OF PRECAST RISER WITH A BONDING AGENT. SIKADUR 31, HI -MOD GEL OR EQUAL #5 REBAR DOWEL 0 10" O.C. EMBED INTO PRECAST 4" MIN. USING SIKADUR ANCHORFIX-2. _-----EXTEND 8" INTO COLLAR AND TERMINATE WITH A 4" 90° HOOK. TYP OF 9. SLINK SEAL FILL INVERT OF STRUCTURE UP TO INVERT OF BARREL WITH 3,000 PSIQ28 DAYS CONC. LINK SEAL CONCRETE COLLAR SECTION- NTS ECT ON NTS 4'-0" NOTE: 1. MIN. SERVICE WEIGHT OF CONC 145 LBS/CY 2. MIN WEIGHT OF STIR PRIOR TO BLOCKOUTS SHALL BE 21,765 LBS. SUBMIT CALCULATIONS SUPPORTING THE INDICATED WEIGHT. 8" MIN. WALL THICKNESS 12" THICK MONOLITHIC CONCRETE BASE OUTSIDE FACE OF STRUCTURE 52" COLLAR HEIGHT 1 NOTE: FOR TRASH RACK AND PROVIDE STEPS ON THE INSIDE AND ALUMINUM—ANTI VORTEX OUTSIDE OF RISER IN ACCORDANCE PLATES SEE SHEET C-5.4 W/ ASTM -478 CO—POLYMER FOR DETAILS POLYPROPLYENE STEEL REINFORCED STEPS 16" O.C. ALIGN WITH TRACK RACK DOOR. J SOLID PRECAST CONCRETE BOX. WAFFLE STYLE BOX NOT ACCEPTABLE. JOINT DESIGN SHALL CONFORM TO ASTM C-478. JOINT SHALL BE SEALED USING BUTYL RUBBER SEALANT CONFORMING TO ASTM -990. PARGE JOINTS INSIDE AND OUT WITH NON— SHRINK GROUT. BLOCKOUT BY PRECASTER. IF BLOCKOUT BY PRECAST DIFFERS THAN WHAT IS SHOWN THE -COLLAR MAY NEED TO BE ADJUSTED TO MAINTAIN THE DIMENSIONS SHOWN AT NO COST TO THE OWNER 24" D.I. OUTLET PIPE INV. 777.00 FILL INVERT OF STRUCTURE UP TO INVERT OF BARREL WITH 3,000 PSI@28 DAYS CONC. ELEV 777.00 6" WASHED #57 S1`l7NE LEVELING COURSE 12" SURGE STONE STABILIZATION 7'-4" OUTLET STRUCTURE SECTION A -A 64" COLLXR WIDTH - 16 MIN 1 TT (--,8" 1 + r 24" DUCTILE IRON OUTLET PIPE 6„ COAT SURFACE OF PRECAST RISER WITH A BONDING AGENT. SIKADUR 31, HI -MOD GEL OR EQUAL 24" D.I. 25.8" 0. D. #5 REBAR DOWEL @ 10" O.C. EMBED INTO PRECAST 4" MIN. USING SIKADUR ANCHORFIX-2. ZEXTEND 8" INTO COLLAR AND TERMINATE WITH A 4" 90' HOOK. TYP OF 9. BLOCKOUT BY PRECASTER. IF BLOCKOUT BY PRECAST DIFFERS THAN WHAT IS SHOWN THE COLLAR MAY NEED TO BE ADJUSTED TO MAINTAIN THE DIMENSIONS SHOWN AT NO COST TO THE OWNER 12.2" MIN PROVIDE A SOLID CONCRETE BLOCK TO SUPPORT PIPE DURING LINK SEAL INSTALLATION AND POURING OF FLOOR. CONCRETE COLLAR ELEVATION- NTS LEVAT ON NTS TRASH RACK SEE C-5.4 ZL PROVIDE STEPS ON THE INSIDE AND OUTSIDE OF THE RISER IN ACCORDANCE W/ ASTM -478 CO—POLYMER POLYPROPLYENE STEEL REINFORCED STEPS 16" O.C. ALIGN WITH TRASH RACK DOOR. CONCRETE COLLAR BY CONTRACTOR SEE DETAILS 1 & 2 ° THIS SHEET ` L_ 12" da d, 24" D.I. OUTLET PIPE 18" ELEV. 791.00 8" MIN. WALL THICKNESS 4'-0" 28" BLOCK OUT FOR /24" D.I. PIPE BY PRECASTER LINK -SEAL (LS -425-C-23) IN 28 -INCH CAST OR CORED HOLE. CONFIRM HOLE DIA PRIOR TO CASTING BOTTOM OF STIR. 776.50 e INVERT 777.00 d d 12" THICK MONOLITHIC CONCRETE BASE 71-4" VALVE OPERATING STEM REMOVEABLE VALVE WRENCH WITH HAND WHEEL ON TOP. PROVIDE CHAIN AND LOCK FOR SECURING WRENCH TO TRASH RACK. SECTION A—A EXTENSION STEM WITH 2" OPERATING NUT ON TOP ATTACH STEM TO OPERATING NUT TO PREVENT REMOVAL 6" RESILIENT WEDGE GATE VALVE - F.L. ENDS SHALL MEET AWWA C509 FILL INV OF STRUCTURE UP TO INVERT OF BARREL (6"t) MONOLITHINC CONCRETE BASE SECTION FIELD CORE FOR 6" SCH 40 PVC DRAWDOWN PIPE. PRECASTER TO BLOCKOUT REINFORCING IN THI- FILL VOID WITH A NON -SHRINK INVERT 788.00 6" PVC PIPE TURNED DOWN TO 6" BELOW NORM POOL ELEVATION. NORMAL POOL ELEV. 788.00 C( 6" 6" CAP W/ 3"0 HOLE LINK -SEAL TRASH GUARD FOR BOTTOM DRAIN, SEE SHEET C-5.4 6" DRAIN PIPE & GATE VALVE /SEE DETAIL THIS SHEET. OUTLET STRUCTURE SECTION B -B ELEV 777.00 16" WASHED #57 STONE LEVELING COURSE 12" SURGE STONE STABILIZATION 12" MAX. 6" a \ 4 a' ° 46 a ° a ° c a BED VALVE IN NON—SHRINK GROUT FOR SUPPORT BOTTOM DRAIN VALVE NTS PRECAST TRUCTURE SECURE STEM GUIDE BRACKET TO WALL USING EXPANSION ANCHORS SECURE STEM GUIDE BRACKET TO WALL USING EXPANSION ANCHORS 6" DUCTILE IRON PIPE FL—FL 6" FLANGE W/ 3"0 EXTENSION TO TEMP SKIMMER PIPE. ATTACH W/ FERNCO COUPLING. REMOVE AFTER SITE IS STABILIZED AND BASIN CAN BE REMOVED. MINIMUM DEPTH REQ.'D TO INSTALL ASSEMBLY LINK—SEAL \(LS -410—C-10) IN 10—INCH CAST OR CORED HOLE. CONFIRM HOLE DIA PRIOR TO CASTING NOTE: TRASH RACK NOT OUTSIDE A �� SHOWN FOR CLARITY OUTLET STRUCTURE PLAN VIEW NTS v NTS NTS 6" BOTTOM DRAIN PIPE 4" TAW stimmel LANDSCAPE ARCHITECTURE CIVIL ENGINEERING LAND PLANNING 601 N. TRADE STREET, SUITE 200 WINSTON-SALEM, NC 27101 P: 336.723.1067 F: 336.723.1069 www.stimmelpa.com SEALS: NCBEES CERT. NO.: C-1347 •`` %% "CA"I"� ✓ - v SEAL - 23552 ' ,4�, � F; q- ........... I CLIENT: CLEMMONS TC, LLC 16501 NORTHCROSS DRIVE SUITE D HUNTERSVILLE, NC 28078-5040 DRAWN: CYNIC DATE: 1/31/2017 REVISIONS: 3/27/2017 CITY/VILLAGE/OWNER COMMENTS JOB. NO: 15-226 SHEET TITLE: WET DETENTION POND OUTLET STRUCTURE DETAILS SCALE: AS NOTED SHEET NO.: ■ © STIMMEL ASSOCIATES, P.A. 3"x 1 /4" JM. ANGLE 1/2" [1] ALUM. BARS 6" OCEW, VERTICAL BARS OVER HORIZONTAL BARS (TYP) NOTE: WELD BARS AT ALL INTERSECTIONS l VIV I �Hl VK 0 FIELD MEASURE PRECAST CONCRETE RISER PRIOR TO FABRICATING THE TRASH RACK AND ANTI—VORTEX FRAME. TRASH RACK PLAN VIEW NTS V-10 5 FLAT (WELD ✓FULL LENGTH) 4'-1 1/2" 2"x 1 /4" ALUM. FLAT BAR STIFFENER (WELD FULL LENGTH) ANTI -VORTEX FRAME SECTION A—A NTS F 44 w iR SO V z 3 3"x3"x 1 /4' ALUM. ANGLE 2 3"x1 /4" ALUM. TRASH RACK ELEVATION NTS 2"x2"x 1 /4" ALUM. ANGLE 311 WELD TO HINGED / FRAME OF TRASH RACK (FULL LENGTH) '-7 1/4" 2"x2"x 1 /4" ALUM. ANGLE 1/4" ALUM. PLATE 1'-10 5/8" 3" E DETAIL 4 IS SHEET FOR TI -VORTEX SEMBLY '-3 1/2"L X 1/2" DIA. ALUM. ROD '/ THREADED ENDS ROVIDE 1/2" DIA. 'ASHERS AND NUTS T EACH END <3"x1 /4" UM. ANGLE OUTSIDE FACE OF RISER STRUCTURE ANTI -VORTEX FRAME SECTION B—B NTS 3"x4"x1� ALUM. ANC (T` SECURE TRASH RACK TO RISER STRUCTURE USING STAINLESS STEEL ANCHORS 12" OC. HINGE ASSEMBLY 3/4" DIA. HOLE (TYP OF 2) TRASH RACK SECTION A—A NTS FA1 PLAN VIEW 3'-6" ALIGN DOOR WITH STEPS DETAIL 4 S SHEET FOR FI -VORTEX >EMBLY ,E FACE "ER PURE ANGLE TO RISER STRUCTURE AND EXTENDED BASE USING STAINLESS STEEL EXPANSION ANCHORS "x1/4" ALUM. _E SIDE DP FRAME AST PAD RISER 1 CTU R E OUTSI[ 0 STF f ANTI -VORTEX PANEL NOT WELDED TO HINGED FRAME .0 YYLL✓L✓ IV IIIIVVL✓ PLAN VIEW FRAME OF TRASH RACK ANTI -VORTEX FRAME NTS 1 /2"M ALUM. BARS 4" OC EACH FACE WELD AT ALL CONNECTIONS M- SECTON A -A ELEVATION - BOTTOM LEVAT 0NBOTTOM D RAIN TRASH GUARD. NTS NOTE THE TRASH RACK SHALL BE LOCKABLE AND HINGED. TAW stimmel LANDSCAPE ARCHITECTURE CIVIL ENGINEERING LAND PLANNING 601 N. TRADE STREET, SUITE 200 WINSTON-SALEM, NC 27101 P: 336.723.1067 F: 336.723.1069 www.stimmelpa.com SEALS: NCBEES CERT. NO.: C-1347 •``�N"CA"I1's'—nom S _ SEAL - 23552 F; 0B�G I NE PROJECT: z O CLIENT: CLEMMONS TC, LLC 16501 NORTHCROSS DRIVE SUITE D HUNTERSVILLE, NC 28078-5040 DRAWN: CY,WC DATE: 1 /2" DIA. x 3" REVISIONS: ,3/27/2017 CITY/VILLAGE/OWNER COMMENTS STAINLESS STEEL EXPANSION ANCHOR (TYP) EXTENDED BASE P JOB. NO: 15-226 OF RISER STRUCTURE SECTON A -A ELEVATION - BOTTOM LEVAT 0NBOTTOM D RAIN TRASH GUARD. NTS NOTE THE TRASH RACK SHALL BE LOCKABLE AND HINGED. TAW stimmel LANDSCAPE ARCHITECTURE CIVIL ENGINEERING LAND PLANNING 601 N. TRADE STREET, SUITE 200 WINSTON-SALEM, NC 27101 P: 336.723.1067 F: 336.723.1069 www.stimmelpa.com SEALS: NCBEES CERT. NO.: C-1347 •``�N"CA"I1's'—nom S _ SEAL - 23552 F; 0B�G I NE PROJECT: z O CLIENT: CLEMMONS TC, LLC 16501 NORTHCROSS DRIVE SUITE D HUNTERSVILLE, NC 28078-5040 DRAWN: CY,WC DATE: 1/31/2017 REVISIONS: ,3/27/2017 CITY/VILLAGE/OWNER COMMENTS JOB. NO: 15-226 SHEET TITLE: WET DETENTION POND TRASH RACK DETAILS SCALE: AS NOTED SHEET NO C-5.4 ©STIMMEL ASSOCIATES, P.A. POND CONSTRUCTION SPECIFICATIONS: A. PRECAST STRUCTURE SPECIFICATIONS 1. STRUCTURE DESIGN SPECIFICATIONS SHALL CONFORM TO LATEST ASTM C913 SPECIFICATIONS FOR "PRECAST CONCRETE WATER AND WASTEWATER STRUCTURES" AND NCDOT STANDARDS. 2. CONCRETE COMPRESSIVE STRENGTH 4,000 PSI MINIMUM. 3. IN-PLACE MINIMUM WEIGHT OF CONCRETE SHALL BE 145 LBS/CF. 4. STEEL REINFORCING DESIGN TO CONFORM TO THE REQUIREMENTS OF ASTM C890 SPECIFICATIONS FOR" STRUCTURAL DESIGN LOADING FOR WATER AND WASTEWATER STRUCTURES" AND SHALL UTILIZE GRADE 60 RE -BARS CONFORMING TO THE REQUIREMENTS OF ASTM A615 OR WWF CONFORMING TO THE REQUIREMENTS OF ASTM A185 OR BOTH. 5. PROVIDE ADDITIONAL REINFORCING AT OPENINGS. 6. STRUCTURE TO BE DESIGNED FOR FULL HYDROSTATIC LOADING RESULTING FROM WATER LEVELS TO THE TOP OF THE DAM OR HS -20 TRAFFIC LOADING, WHICHEVER IS GREATER. 7. STEPS REQUIRED AS SHOWN. STEPS SHALL BE STEEL REINFORCED COPOLYMER POLYPROPYLENE PLASTIC AND MEET THE REQUIREMENTS OF ASTM C478. 8. JOINT DESIGN TO CONFORM TO ASTM C-478. JOINTS TO BE SEALED WITH BUTYL RUBBER JOINT SEALANT CONFORMING TO THE REQUIREMENTS OF ASTM C990. PARGE JOINTS INSIDE AND OUT USING NON -SHRINK GROUT. 9. STRUCTURAL DRAWINGS AND CALCULATIONS SEALED BY A NC PROFESSIONAL ENGINEER ARE REQUIRED. THE ABOVE MIN. REQUIREMENTS SHALL BE STATED IN SUBMITTED MATERIAL. 10. THE EXTERIOR OF THE PRECAST STRUCTURE SHALL CONFORM TO THE FOLLOWING: A. EXTERIOR FINISH SHALL BE UNIFORM IN COLOR, TEXTURE AND APPEARANCE. B. LIFT POINTS SHALL BE HIDDEN. C. THE EXTERIOR FACE OF THE PRECAST STRUCTURE SHALL BE CONSTRUCTED USING GOOD INDUSTRY PRACTICES SUCH AS CLEANING OF FORMS, DESIGN OF CONCRETE MIX, PLACING AND CURING. NO MAJOR OR UNSIGHTLY IMPERFECTIONS, HONEYCOMBS OR OTHER DEFECTS WILL BE PERMITTED. EACH PRECAST UNIT SHALL PRESENT A SMOOTH, STRAIGHT, UNIFORM AND CLEAN SURFACE W/O PAINTING. NO COMPANY LOGO, SHIPPING INFO OR OTHER IDENTIFYING MARKINGS ARE PERMITTED ON THE EXTERIOR OF THE UNIT. D. THE TOP SURFACE OF THE UNIT SHALL BE LEVEL, UNIFORM IN FINISH AND ELEVATION. B. PRINCIPAL SPILLWAY PIPE DUCTILE IRON PIPE PRESSURE CLASS 50 CONFORMING TO ANSI C151 C. SEEPAGE DIAPHRAGM 1. SAND: ASTM C33 ("CLEAN NATURAL SAND," MANUFACTURED SAND MATERIALS AND ROCK SCREENINGS ARE NOT PERMITTED) 2. SAND COMPACTION: THE MINIMUM DRY DENSITY OF THE COMPACTED SAND SHALL BE EQUAL TO 95 PERCENT OF THE DRY DENSITY OBTAINED BY COMPACTING A SINGLE SPECIMEN OF SAND USING THE ENERGY AND METHODS DESCRIBED IN ASTM D698A. THE TEST CONSISTS OF A ONE POINT TEST PERFORMED ON SAND THAT HAS BEEN AIR DRIED THOROUGHLY PRIOR TO COMPACTION. 3. DIAPHRAGM DRAINAGE PIPE: A. WITHIN DIAPHRAGM SAND: SLOTTED SCH. 40 PVC -SLOT WIDTH 0.01" OR LESS. B. OUTSIDE DIAPHRAGM SAND: SOLID SCH. 40 PVC. D. ROCK RIP RAP ROCK RIP RAP SHALL MEET THE REQUIREMENTS OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION, STANDARD SPECIFICATIONS, SECTION 1042. THE RIP RAP SHALL BE PLACED TO THE REQUIRED THICKNESS IN ONE OPERATION. THE ROCK SHALL BE DELIVERED AND PLACED IN A MANNER THAT WILL INSURE THE RIP RAP IN PLACE SHALL BE REASONABLY HOMOGENEOUS WITH THE LARGER ROCKS UNIFORMLY DISTRIBUTED AND FIRMLY IN CONTACT ONE TO ANOTHER WITH THE SMALLER ROCKS FILLING THE VOIDS BETWEEN THE LARGER ROCKS. FILTER CLOTH SHALL BE PLACED UNDER ALL RIP RAP AND SHALL MEET THE REQUIREMENTS OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION, STANDARD SPECIFICATIONS, SECTION 1056, TYPE 2. E. CARE OF WATER DURING CONSTRUCTION ALL WORK ON THE PERMANENT STRUCTURES SHALL BE CARRIED OUT IN AREAS FREE FROM WATER. THE CONTRACTOR SHALL CONSTRUCT AND MAINTAIN ALL TEMPORARY DIKES, LEVEES, COFFER DAMS, DRAINAGE CHANNELS, AND STREAM DIVERSIONS NECESSARY TO PROTECT THE AREAS TO BE OCCUPIED BY THE PERMANENT WORKS. THE CONTRACTOR SHALL ALSO FURNISH, INSTALL, OPERATE AND MAINTAIN ALL NECESSARY PUMPING AND OTHER EQUIPMENT REQUIRED FOR REMOVAL OF WATER FROM THE VARIOUS PARTS OF THE WORK AND FOR MAINTAINING THE EXCAVATIONS, FOUNDATION, AND OTHER PARTS OF THE WORK FREE FROM WATER AS REQUIRED OR DIRECTED BY THE ENGINEER FOR CONSTRUCTING EACH PART OF THE WORK. AFTER HAVING SERVED THEIR PURPOSE, ALL TEMPORARY PROTECTIVE WORKS SHALL BE REMOVED OR LEVELED AND GRADED TO THE EXTENT REQUIRED TO PREVENT OBSTRUCTION IN ANY DEGREE WHATSOEVER OF THE FLOW OF WATER TO THE SPILLWAY OR OUTLET WORKS AND SO AS NOT TO INTERFERE IN ANY WAY WITH THE OPERATION OR MAINTENANCE OF THE STRUCTURE. STREAM DIVERSIONS SHALL BE MAINTAINED UNTIL THE FULL FLOW CAN BE PASSED THROUGH THE PERMANENT WORKS. THE REMOVAL OF WATER FROM THE REQUIRED EXCAVATION AND THE FOUNDATION SHALL BE ACCOMPLISHED IN A MANNER AND TO THE EXTENT THAT WILL MAINTAIN STABILITY OF THE EXCAVATED SLOPES AND BOTTOM OF REQUIRED EXCAVATIONS AND WILL ALLOW SATISFACTORY PERFORMANCE OF ALL CONSTRUCTION OPERATIONS. DURING THE PLACING AND COMPACTING OF MATERIAL IN REQUIRED EXCAVATIONS, THE WATER LEVEL AT THE LOCATIONS BEING REFILLED SHALL BE MAINTAINED BELOW THE BOTTOM OF THE EXCAVATION AT SUCH LOCATIONS WHICH MAY REQUIRE DRAINING THE WATER TO SUMPS FROM WHICH THE WATER SHALL BE PUMPED. F. EROSION AND SEDIMENT CONTROL CONSTRUCTION OPERATIONS SHALL BE CARRIED OUT IN SUCH A MANNER THAT EROSION WILL BE CONTROLLED AND WATER AND AIR POLLUTION MINIMIZED. STATE AND LOCAL LAWS CONCERNING POLLUTION ABATEMENT SHALL BE FOLLOWED. CONSTRUCTION PLANS DETAIL EROSION AND SEDIMENT CONTROL MEASURES TO BE EMPLOYED DURING THE CONSTRUCTION PROCESS. G. MAINTENANCE SCHEDULE SEE PROJECT OPERATION AND MAINTENANCE AGREEMENT. H. REQUIRED SUBMITTALS 1. SUBMITTALS FOR THE FOLLOWING ITEMS ARE REQUIRED TO BE APPROVED PRIOR TO BEGINNING CONSTRUCTION. THE ENGINEER WILL ATTEMPT TO REVIEW THE SUBMITTALS WITHIN 10 BUSINESS DAYS OF RECEIPT. NOTE: MATERIAL SUBSTITUTIONS ARE NOT ALLOWED, UNLESS SPECIFICALLY REQUESTED IN WRITING AND APPROVED BY THE ENGINEER. REQUESTS FOR MATERIAL SUBSTITUTES ARE NOT RECOMMENDED AND MAY DELAY APPROVAL. CONTRACTOR SHALL PROVIDE SUBMITTAL AND REQUEST FOR ANY MATERIAL SUBSTITUTIONS WELL IN ADVANCE TO AVOID POTENTIAL DELAY. A. DUCTILE IRON PIPE. B. PRECAST STRUCTURE - SEALED STRUCTURAL CALCULATIONS - SHOP DRAWING OF STRUCTURE WITH COMPLETE DETAILS OF JOINTS, STEEL PLACEMENT, STEPS, BLOCKOUTS, ETC. - WEIGHT OF STRUCTURE BEFORE BLOCKOUTS - CONCRETE MIX DESIGN W/ UNIT WEIGHT OF CONCRETE C. CAST IN-PLACE CONCRETE MIX DESIGN WITH UNIT WEIGHT SPECIFIED. D. LINK -SEAL CUT SHEET. E. TRASH RACK SHOP DRAWING. F. BOTTOM DRAIN AND APPEARANCES. G. SAND GRADATION REPORT OF ACTUAL SAND TO BE USED IN SEEPAGE CONTROL FOR THIS PROJECT.. H. SEEPAGE PIPING WITH SPECIFIED OPENINGS. I. NON -SHRINK GROUT. J. BUTYL JOINT SEALER. 0 00 r 00 N M O Z 0 Q U L� U W d 0 Z 0 a Lo 0 Lo N N !s I. INSPECTION SCHEDULE IT IS CRITICAL FOR SEVERAL ITEMS TO BE INSPECTED AT THE APPROPRIATE TIME DURING CONSTRUCTION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE ENGINEER AT LEAST 2 DAYS PRIOR TO BEGINNING WORK ON THESE ITEMS TO SCHEDULE INSPECTIONS. THE ITEMS ARE AS FOLLOWS AS THEY APPLY TO EACH DAM. ANY ITEMS CONSTRUCTED AND COVERED UP PRIOR TO OBSERVATION WILL BE UNCOVERED OR TESTING WILL BE PROVIDED AS APPROPRIATE AT THE CONTRACTOR'S EXPENSE. 1. THE CUTOFF TRENCH SHALL BE INSPECTED AFTER EXCAVATION AND PRIOR TO PLACING BACKFILL. 2. BARREL PLACEMENT BEFORE AND DURING BACKFILL. 3. BARREL SEEPAGE DIAPHRAGM BEFORE SAND PLACEMENT. 4. RISER STRUCTURE SUBGRADE PRIOR TO PLACEMENT. 5. EMERGENCY SPILLWAY PRIOR TO MATTING PLACEMENT. 6. CONCRETE COLLAR AT OUTLET STRUCTURE PRIOR TO PLACING CONCRETE. 7. LINER PLACEMENT BEFORE AND DURING BACKFILL. J. SURVEY REQUIREMENTS: 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SURVEYING REQUIRED BY THE CONSTRUCTION DOCUMENTS. THIS SHALL INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING: GRADING, RISER STRUCTURE, BARREL, AND ENERGY DISSIPATERS, ETC. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR A FINAL AS -BUILT SURVEY OF THE POND. THE AS -BUILT SURVEY SHALL INCLUDE THE FOLLOWING ITEMS AS THEY APPLY: A. POND/ DAM GRADING WITH 1 FOOT CONTOURS AND SPOT ELEVATIONS ALONG CENTER TOP OF DAM IN 25 FOOT INTERVALS AND AT LOWEST POINT B. TOP OF RISER ELEVATION (ALL 4 CORNERS) AND UPSTREAM AND DOWNSTREAM INVERTS OF BARREL C. INVERT OF DRAW DOWN PIPES AND BOTTOM DRAIN D. INVERT AND WIDTH OF EMERGENCY SPILLWAY E. BOTTOM OF POND ELEVATION F. LOCATION AND DIMENSIONS OF RIP RAP DISSIPATER PAD(S) 3. IF THE AS -BUILT SURVEY DOES NOT COMPLY WITH THE CONSTRUCTION DOCUMENTS THE CONTRACTOR WILL BE REQUIRED TO CORRECT THE DEFICIENT ITEMS AND WILL BE RESPONSIBLE FOR REVISING THE AS -BUILT SURVEY. 4. PROVIDE AN AUTOCAD DRAWING AND SEALED HARDCOPY BY A REGISTERED LAND SURVEYOR OF THE FINAL AS BUILT SURVEY TO ENGINEER. K. PERMANENT SEEDING ALL DISTURBED AREAS TO BE SEEDED WITH AN EVEN MIXTURE OF REBEL II, FALCON AND JAGUAR FINE FESCUES AT A RATE OF 5-6 LBS./1,000 S.F. SO AS TO PRODUCE A THICK, FIRM STAND OF GRASS. FERTILIZE AT A RATE OF 10 LBS./1,000 S.F. WITH A SLOW-RELEASE FERTILIZER (USE STRAW AND ASPHALT EMULSION TO COVER SEED UNTIL STABLE.) APPLY LIME ACCORDING TO SOIL TEST, OR APPLY 4,000 LBS./ACRE SLOW-RELEASE PELLETIZED AGRICULTURAL LIMESTONE. SEEDING DATES: AUG. 20 THROUGH OCT. 25 AND FEB. 1 THROUGH MAY. SEEDBED PREPARATION: 1. REMOVE ANY UNDESIRABLE GROUND COVERS INCLUDING ANY TEMPORARY SEEDING. 2. RIP THE AREA TO BE SEEDED TO A MIN. DEPTH OF 4"-6." 3. REMOVE ALL LOOSE ROCKS, ROOTS, ETC. LEAVING SURFACE SMOOTH AND UNIFORM. 4. APPLY SEED, AGRICULTURAL LIME, AND FERTILIZER UNIFORMLY AND MIX WITH THE SOIL. 5. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. 6. ESTABLISH FULL STAND OF GRASS, RESEEDING MAY BE NECESSARY. L. CONSTRUCTION SEQUENCE I. EXCAVATE THE CUT-OFF TRENCH AND BACKFILL WITH APPROVED MATERIAL TO A MINIMUM OF 1 -FOOT ABOVE THE TOP OF BARREL. 2. TRENCH THROUGH CUT-OFF TRENCH MATERIAL AND INSTALL THE BARREL. 3. INSTALL THE SEEPAGE DIAPHRAGM AROUND THE BARREL. 4. BACKFILL THE BARREL AND DAM TO THE ELEVATIONS SHOWN ON C-5.1. 5. INSTALL THE RISER, COLLAR AND BOTTOM DRAIN TO ATTACH THE THE EROSION CONTROL SKIMMER. 6. COMPLETE THE DAM FILL AND POND EXCAVATION. 7. INSTALL POND LINER. 8. EXCAVATE THE EMERGENCY SPILLWAY. 9. INSTALL THE TRASH RACK. 10. SEED AND MULCH ALL DISTURBED AREAS. 11. PLAN VEGETATED BENCH. M. SOIL POND LINER SPECIFICATION AND PERFORMANCE 1.THE SOIL POND LINER SHALL HAVE A MAXIMUM PERMEABILITY RATE OF 1 X10-5 CM/SEC (0.01 "/HR). THE POND LINER MATERIAL SHALL BE A MINIMUM OF 12 -INCHES THICK, GENERALLY RESTRICTED TO THE ML, MH, SC CL, AND CH SOILS AND COMPACTED TO NOT LESS THAN 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D-698) WITH A MOISTURE CONTENT WITHIN 2% DRY TO 5% WET OF THE OPTIMUM UNLESS OTHERWISE APPROVED BY THE GEOTECHNICAL ENGINEER. 2.THE GEOTECHNICAL ENGINEER SHALL TEST AND CONFIRM IN WRITING THE SUITABILITY OF THE SOILS IDENTIFIED BY THE CONTRACTOR FOR USE IN THE LINER. 3.ONSITE SOILS THAT ARE SUITABLE FOR USE IN THE POND LINER MAY REQUIRE HANDLING MULTIPLE TIMES FOR DRYING, STOCKPILING AND PLACEMENT. 4.THE POND LINER SHALL FULLY ENCOMPASS THE WETTED PERIMETER OF THE POND INCLUDING THE BOTTOM AND SIDE SLOPES. THE LINER IS NOT REQUIRED ON THE PLANTED SHELF OR ABOVE THE PLANTED SHELF ELEVATION. 5.COMPLETION OF THE POND AS BUILTS, THE ENGINEER'S CERTIFICATION, AND THE OWNER OBTAINING A CERTIFICATE OF OCCUPANCY SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF ENSURING THE POND MAINTAINS THE DESIGNED WATER (NORMAL POOL) ELEVATION. 6.THE CONTRACTOR IS RESPONSIBLE FOR NOTIFYING THE GEOTECHNICAL TESTING COMPANY OF THE DAILY POND CONSTRUCTION ACTIVITIES TO ENSURE THE REQUIRED CONSTRUCTION TESTING IS PERFORMED. FAILURE TO NOTIFY THE GEOTECHNICAL TESTING COMPANY MAY REQUIRE THE CONTRACTOR TO RECONSTRUCT THE PORTION OF THE POND THAT WASN'T TESTED AT NO COST TO THE OWNER. 7.THE WATER ELEVATION WILL BE MONITORED DURING THE CONTRACTORS CONTRACTUAL WARRANTY PERIOD TO ENSURE THE NORMAL POOL ELEVATION REMAINS CONSISTENT WITH RAINFALL AMOUNTS. IF THE POND FAILS TO MAINTAIN THE PERMANENT POOL THROUGHOUT THE WARRANTY PERIOD, THE CONTRACTOR SHALL RETURN TO THE SITE AND PROVIDE REMEDIAL WORK AS NECESSARY TO CORRECT THE PROBLEM. POND LINER CONSTRUCTION SEQUENCE 1.NOTIFY THE GEOTECHNICAL ENGINEER THAT THE POND EXCAVATION IS PROCEEDING. 2.EXCAVATE THE POND BODY TO THE ELEVATIONS SHOWN ON THE PLANS (PLAN ELEVATIONS WILL BE FINISHED ELEVATIONS, NOT ELEVATIONS TO BUILD THE LINER FROM) AND REQUEST THE GEOTECHNICAL ENGINEER PERFORM A SITE VISIT TO CONFIRM THE SOILS IN THE BOTTOM OF THE POND ARE CONSISTENT WITH THE GEOTECHNICAL REPORT AND PROVIDE GUIDANCE ON LINER INSTALLATION. THE GEOTECHNICAL ENGINEER SHALL ISSUE WRITTEN CONFIRMATION OF THE EXISTING CONDITIONS AND IF ANY MODIFICATIONS TO THE SPECIFIED POND LINER ARE REQUIRED. 3.INSTALL THE POND LINER AS SHOWN ON THE DRAWINGS AND SPECIFICATIONS. 4.THE GEOTECHNICAL ENGINEER SHALL WITNESS INSTALLATION AND PERFORM SUFFICIENT TESTS TO CONFIRM IN WRITING THAT THE POND LINER WAS CONSTRUCTED IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS SPECIFICALLY: MATERIAL CLASSIFICATION, SUBGRADE CONDITION, THICKNESS, MOISTURE CONTENT, AND COMPACTION. 5.IF THE POND IS USED AS A TEMPORARY SEDIMENT BASIN THEN THE LINER SHALL BE INSTALLED AFTER THE SEDIMENT BASIN IS CONVERTED TO THE PERMANENT STORMWATER POND. 6.A GEO-TECHNICAL ENGINEER SHALL VERIFY/CERTIFY THAT THE LINER ONCE INSTALLED IS ACHIEVING A MINIMUM INFILTRATION OF 0.01 IN/HR PRIOR TO DESIGN ENGINEERS SUBMITTAL OF AS -BUILT DRAWINGS & CERTIFICATION OF THE STORMWATER MANAGEMENT SYSTEM. N. TEMPORARY SEEDING SPECIFICATION FOR LATE WINTER/EARLY SPRING: SEEDING MIXTURE SPECIES: RATE (LB/ACRE): RYE (GRAIN) 120 ANNUAL LESPEDEZA 50 (KOBE IN PIEDMONT & COASTAL PLAIN, KOREAN IN MOUNTAINS) SEEDING DATES MOUNTAINS --FEB. 1 - MAY 1 PIEDMONT --JAN. 1 - MAY 1 COASTAL PLAIN --DEC. 1 - APR. 15 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 AOCH RLIaDRb LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. FOR SUMMER: SEEDING MIXTURE SPECIES: RATE (LB/ACRE): GERMAN MILLET 40 IN THE PIEDMONT AND MOUNTAINS, A SMALL -STEMMED SUDAN GRASS MAY BE SUBSTITUTED AT A RATE OF 50 LB/ACRE. SEEDING DATES MOUNTAINS --MAY 15 - AUG. 15 PIEDMONT --MAY 1 - AUG. 15 COASTAL PLAIN --APR. 15 - AUG. 15 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. a DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. FOR FALL: SEEDING MIXTURE SPECIES: RATE (LB/ACRE): RYE (GRAIN) 120 SEEDING DATES MOUNTAINS --AUG. 15 - DEC. 15 PIEDMONT AND COASTAL PLAIN --AUG. 15 - DEC. 30 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 1,000 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOPDRESS WITH 50 LB/ACRE OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 LB/ACRE KOBE (PIEDMONT AND COASTAL PLAIN) OR KOREAN (MOUNTAINS) LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. SEEDBED PREPARATION: 1. RIP AREA TO BE SEEDED TO A MINIMUM DEPTH OF 4-6 INCHES. 2. REMOVE ALL LOOSE ROCKS, ROOTS, ETC. LEAVING SURFACE SMOOTH AND UNIFORM. 3. APPLY SEED, AGRICULTURAL LIME, FERTILIZER AND SUPER PHOSPHATE UNIFORMLY AND MIX WITH THE SOIL. 4. SEED ON A FRESHLY PREPARED SEEDBED AND COVER THE SEED LIGHTLY WITH SEEDING EQUIPMENT OR CULTIPACK AFTER SEEDING. 5. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. stimmel LANDSCAPE ARCHITECTURE CIVIL ENGINEERING LAND PLANNING 601 N. TRADE STREET, SUITE 200 WINSTON-SALEM, NC 27101 P: 336.723.1067 F: 336.723.1069 www.stimmelpa.com SEALS: NCBEES CERT. NO.: C-1347 N CA yv0 �7: SEAL r' - 23552 - =�L : 3 - 2-7-171 c,?: PROJECT: z 0 Cn Z O" z IIM �z 0 W � JW UJ U CLIENT: CLEMMONS TC, LLC 16501 NORTHCROSS DRIVE SUITE D HUNTERSVILLE, NC 28078-5040 DRAWN: CY,WC DATE: 1/31/2017 REVISIONS: 0 3/27/2017 CITY/VILLAGE/OWNER COMMENTS JOB. NO: 15-226 SHEET TITLE: WET DETENTION POND SPECIFI CATIONS SCALE: AS NOTED SHEET NO.: C-5.5 © STIMMEL ASSOCIATES, P.A. Water Resource W Envirommentnl Quality February 9, 2017 Clemmons Town Center LLC Attn: Steven Hankins 16501 Northcross Drive, Suite D Huntersvill'e NC 28078 ROY COOPER Crnwv'nnr MICHAEL S. BEGAN S. JAY ZIMMERMA.N 144 cc l DWR # 2016-1153 Forsyth County Subjects Approval of Individual 401 Water Quality Certification with Additional Conditions Clemmons Town Center Shopping Center USAGE Action ID. No. SAW -2016-02360 Dear Mr. Hankins: Attached hereto is a copy of Certification No. WQC004084 issued to Mr. Steven Hankins and Clemmons Town Center LLC, dated February 9, 2017. Please note that you should get any other federal, state or local permits before proceeding with the subject project, including those required by (but not limited to) Sediment and Erosion Control, Non -Discharge, and Water Supply Watershed regulations. This approval and its conditions are final and binding unless contested. This Certification can be contested as provided in General Statute 1506 by filing a written petition for an administrative hearing to the Office of Administrative Hearings (hereby known as OAH) within sixty (60) calendar days. A petition form may be obtained from the OAH at http://www.ncoah.com/ or by calling the OAH Clerk's Office at (919) 431-3000 for information. A petition is considered filed when the original and one (1) copy along with any applicable OAH filing fee is received in the OAH during normal office hours (Monday through Friday between 8:00am and 5:00pm, excluding official state holidays). The petition may be faxed to the OAH at (919) 431-3100, provided the original and one copy of the petition along with any applicable OAH filing fee is received by the OAH within five (5) business days following the faxed transmission. State of North Carolina I Environmental Quality 450 W. Hanes Mill Road, Suite 300, Winston-Salem, North Carolina 27105 Phone: 336-776-9800 l FAX: 336-776-9797 Mailing address for the OAH: If sending via US Postal Service: Office of Administrative Hearings 6714 Mail Service Center Raleigh, NC 27699-6714 Clemmons Town Center DWR # 16-1153 Individual Certification #WQC004084 Page 2 of 8 !f sending via delivery service (UPS, FedEx, etc): Office of Administrative Hearings 1711 New Hope Church Road Raleigh, NC 27609-6285 One (1) copy of the petition must also be served to DENR: William F. Lane, General Counsel Department of Environment and Natural Resources 1601 Mail Service Center Raleigh, NC 27699-1601 Unless such a petition is filed, this Certification shall be final and binding. This certification completes the review of the Division under section 401 of the Clean Water Act and 15A NCAC 02H.0500. Contact Sue Homewood at 36-776-9693 or sue.homewood@ncdenr.gov if you have any questions or concerns. Sincerely, WNd Karen Higgins, Supery s 401 & Buffer Permitting Unit ENCLOSURES cc: Brad Luckey, Pilot Environmental Inc (via email) Jean Gibby, USACE Raleigh Regulatory Field Office (via email) Todd Bowers, EPA, Sam Nunn Federal Center, 61 Forsyth Street SW, Atlanta, GA 30303 DWR WSRO 401 file DWR 401 & Buffer Permitting Unit file File name: 161153CIemmonsTownCenter(Forsyth)_401_IC Clemmons Town Center DWR # 16-1153 Individual Certification #WQC004084 Page 3 of 8 NORTH CAROLINA 401 WATER QUALITY CERTIFICATION CERTIFICATION #WQC004084 is issued in conformity with the requirements of Section 401, Public Laws 92-500 and 95-217 of the United States and subject to North Carolina's Regulations in 15 NCAC 02H .0500 to Mr. Steven Hankins and Clemmons Town Center LLC, who have authorization for the impacts listed below, as described within your application received by the N.C. Division of Water Resources (Division) on November 21, 2016 and subsequent information on January 23, 2017, and by Public Notice issued by the U. S. Army Corps of Engineers and received by the Division on December 7, 2016. The State of North Carolina certifies that this activity will not violate the applicable portions of Sections 301, 302, 303, 306, 307 of the Public Laws 92-500 and PL 95-217 if conducted in accordance with the application, the supporting documentation, and conditions hereinafter set forth. This approval requires you to follow the conditions listed in the certification below. Conditions of Certification: 1. The following impacts are hereby approved provided that all of the other specific conditions of the Certification are met. No other impacts are approved, including incidental impacts. [15A NCAC 02H .0506(b) and/or (c)] Type of Impact Amount Approved (units) Permanent Amount Approved (units) Temporary Stream Site SA (intermittent) 574 (linear feet) 0 (linear feet) Site SB (perennial) 19 (linear feet) 0 (linear feet) Site SC (perennial) 44 (linear feet) 12 (linear feet) 404/401 Wetlands Site WA 0.054 (acres) 0 (acres) Site WC 0.0345 (acres) 0.0003 (acres) Site WC (conversion) 0.0167(acres) 0 (acres) 2. This approval is for the purpose and design described in your application. The plans and specifications for this project are incorporated by reference as part of the Certification. If you change your project, you must notify the Division and you may be required to submit a new application package with the appropriate fee. If the property is sold, the new owner must be given a copy of this approval letter and General Certification(s)/Permit/Authorization and is responsible for complying with all conditions. [15A NCAC 02H .0507(d)(2)] Clemmons Town Center DWR # 16-1153 Individual Certification #WQC004084 Page 4 of 8 3. You are required to provide a digital copy of the approved stormwater management plan (SMP), including plan details on full-sized plan sheets, with proof of the Village of Clemmons's approval. The approved SMP shall be submitted to Sue Homewood of the DWR Winston Salem Regional Office (sue.homewood@ncdenr.gov) before any impacts authorized in this certification occur. After it is approved, the SMP may not be modified without prior written authorization from the Village of Clemmons. If modified, a digital copy of the approval letter and modified SMP shall again be submitted to the DWR (at the email address above) prior to the commencement of the modifications. [15A NCAC 02H .0506(b)(5)] 4. The Winston-Salem Regional Office shall be notified in writing once construction at the approved impact areas has commenced. [15A NCAC 02H .0507 (c) and 15A NCAC 02H .0502 (e)] 5. Stream SA (61 linear feet) and Wetland WA (1,685 square feet) downstream of impact areas, shall be visually monitored by Clemmons Town Center LLC for loss of hydrologic function and flow, and to determine if the stream and wetland continue to provide aquatic life propagation and biological integrity per required in North Carolina Administrative Code 15A NCAC 2B .0211(1) and 15A NCAC 2B .0231. Monitoring of Wetland WA shall occur in the area identified in the attached drawing from Stimmel and dated February 8, 2017. Monitoring shall begin at the time upstream impacts/fill occurs and shall continue for a minimum of two years or until hydrologic function and stability is determined by the Division of Water Resources, whichever is longer. Annual reports of visual monitoring and photographic documentation shall be submitted to the Winston-Salem Regional Office on June 1 of each year. 6. All retained wetlands, streams, surface waters, and riparian buffers located within 50 feet of the construction area on the project site shall be clearly marked (example- orange fabric fencing) prior to any land disturbing activities and must be maintained on the property until the project phase is completed. [15A NCAC 02H.0506 (b)(2) and (c)(2) and 15A NCAC 02H .0507 (c)] 7. No waste, spoil, solids, or fill of any kind shall occur in wetlands, waters, or riparian areas beyond the footprint of the impacts depicted in the Pre -Construction Notification for this project. All construction activities, including the design, installation, operation, and maintenance of sediment and erosion control Best Management Practices shall be performed so that no violations of state water quality standards, statutes, or rules occur. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of this permit. [15A NCAC 02H.0501 and .0502] 8. Erosion and sediment control practices must be in full compliance with all specifications governing the proper design, installation and operation and maintenance of such Best Management Practices. If applicable, the project must comply with the specific conditions and requirements of the NPDES Construction Stormwater Permit issued to the site and the following requirements [15A NCAC 02H .0506(b)(3) and (c)(3)]: Clemmons Town Center DWR # 16-1153 Individual Certification #WQC004084 Page 5 of 8 a. Design, installation, operation, and maintenance of the sediment and erosion control measures must be such that they equal or exceed the requirements specified in the most recent version of the North Carolina Sediment and Erosion Control Manual. The devices shall be maintained on all construction sites, borrow sites, and waste pile (spoil) projects, including contractor -owned or leased borrow pits associated with the project. b. For borrow pit sites, the erosion and sediment control measures must be designed, installed, operated, and maintained in accordance with the most recent version of the North Carolina Surface Mining Manual. c. Reclamation measures and implementation must comply with the reclamation in accordance with the requirements of the Sedimentation Pollution Control Act and the Mining Act of 1971. d. Sufficient materials required for stabilization and/or repair of erosion control measures and stormwater routing and treatment shall be on site at all times. 9. Sediment and erosion control measures shall not be placed in wetlands or waters. Exceptions to this condition require application submittal to and written approval by the Division. If placement of sediment and erosion control devices in wetlands and waters is unavoidable, then design and placement of temporary erosion control measures shall not be conducted in a manner that may result in dis-equilibrium of wetlands, stream beds, or banks, adjacent to or upstream and downstream of the above structures. All sediment and erosion control devices shall be removed and the natural grade restored within two (2) months of the date that the Division of Energy, Mineral and Land Resources (DEMLR) or locally delegated program has released the specific area within the project. [15A NCAC 02H .0501 and .05021 10. An NPDES Construction Stormwater Permit is required for construction projects that disturb one (1) or more acres of land. This Permit allows stormwater to be discharged during land disturbing construction activities as stipulated in the conditions of the permit. If your project is covered by this permit, full compliance with permit conditions including the erosion & sedimentation control plan, inspections and maintenance, self-monitoring, record keeping and reporting requirements is required. A copy of the general permit (NCG010000), inspection log sheets, and other information may be found at: http://portal.ncdenr.org/web/wq/ws/su/npdessw#tab-w. 15A NCAC 02H .0506(b)(5) and (c)(5)] 11. All work in or adjacent to stream waters shall be conducted so that the flowing stream does not come in contact with the disturbed area. Approved best management practices from the most current version of the NC Sediment and Erosion Control Manual, or the NC DOT Construction and Maintenance Activities Manual, such as sandbags, rock berms, cofferdams, and other diversion structures shall be used to minimize excavation in flowing water. [15A NCAC 02H .0506(b)(3) and (c)(3)] Clemmons Town Center DWR # 16-1153 Individual Certification #WQC004084 Page 6 of 8 12. If concrete is used during the construction, then all necessary measures shall be taken to prevent direct contact between uncured or curing concrete and waters of the state. Water that inadvertently contacts uncured concrete shall not be discharged to waters of the state due to the potential for elevated pH and possible aquatic life/fish kills. [15A NCAC 02B.0200] 13. Culverts required for this project shall be installed in such a manner that the original stream profiles are not altered and to allow for aquatic life movement during low flows. Existing stream dimensions (including the cross section dimensions, pattern and longitudinal profile) must be maintained above and below locations of each culvert. [15A NCAC 02H .0506(b)(2) and km Placement of culverts and other structures in waters, streams must be below the elevation of the streambed by one (1) foot for all culverts with a diameter greater than 48 inches, and 20 percent of the culvert diameter for culverts having a diameter less than 48 inches, to allow low flow passage of water and aquatic life. Installation of culverts in wetlands must ensure continuity of water movement and be designed to adequately accommodate high water or flood conditions. Additionally, when roadways, causeways, or other fill projects are constructed across FEMA -designated floodways or wetlands, openings such as culverts or bridges must be provided to maintain the natural hydrology of the system as well as prevent constriction of the floodway that may result in destabilization of streams or wetlands. The establishment of native, woody vegetation and other soft stream bank stabilization techniques must be used where practicable instead of rip rap or other bank hardening methods. 14. All temporary fill and culverts shall be removed and the impacted area returned to natural conditions, within 60 days of the determination that the temporary impact is no longer necessary. The impacted areas shall be restored to original grade, including each stream's original cross sectional dimensions, plan form pattern, and longitudinal bed and bed profile, and the various sites shall be stabilized with natural woody vegetation (except approved maintenance areas) and restored to prevent erosion. [15A NCAC 02H .0506(b)(2) and (c)(2)] 15. All temporary pipes/culverts/riprap pads etc, shall be installed in all streams as outlined in the most recent edition of the North Carolina Sediment and Erosion Control Planning and Design Manual so as not to restrict stream flow or cause dis-equilibrium. [15A NCAC 02H .0506(b)(2) and (c)(2)] 16. Any riprap required for proper culvert placement, stream stabilization, or restoration of temporarily disturbed areas shall be restricted to the area directly impacted by the approved construction activity. All riprap shall be buried and/or "keyed in" such that the original stream elevation and streambank contours are restored and maintained. Placement of riprap or other approved materials shall not result in de -stabilization of the stream bed or banks upstream or downstream of the area. [15A NCAC 02H .0506(b)(2)] Clemmons Town Center DW R # 16-1153 Individual Certification #WQC004084 Page 7 of 8 17. Any riprap used for stream stabilization shall be of a size and density to prevent movement by wave action, current action, or stream flows and consist of clean rock or masonry material free of debris or toxic pollutants. Riprap shall not be installed in the streambed except in specific areas required for velocity control and to ensure integrity of bank stabilization measures. [15A NCAC 02H .0506(b)(2)] 18. A one-time application of fertilizer to re-establish vegetation is allowed in disturbed areas including riparian buffers, but is restricted to no closer than 10 feet from top of bank of streams. Any fertilizer application must comply with all other Federal, State and Local regulations. [15A NCAC 02B.0231] 19. This Certification does not relieve the applicant of the responsibility to obtain all other required Federal, State, or Local approvals. 20. Steven Hankins and Clemmons Town Center LLC shall conduct construction activities in a manner consistent with State water quality standards (including any requirements resulting from compliance with section 303(d) of the Clean Water Act) and any other appropriate requirements of State and Federal law. [15A NCAC 026 .0200] If the Division determines that such standards or laws are not being met (including the failure to sustain a designated or achieved use) or that State or federal law is being violated, or that further conditions are necessary to assure compliance, the Division may reevaluate and modify this Certification. Before modifying the Certification, the Division shall notify Steven Hankins and Clemmons Town Center LLC and the U.S. Army Corps of Engineers, provide public notice in accordance with 15A NCAC 02H .0503 and provide opportunity for public hearing in accordance with 15A NCAC 02H .0504. Any new or revised conditions shall be provided to Steven Hankins and Clemmons Town Center LLC in writing, shall be provided to the U.S. Army Corps of Engineers for reference in any Permit issued pursuant to Section 404 of the Clean Water Act, and shall also become conditions of the 404 Permit for the project. 21. This approval is for the purpose and design described in your application and as described in the Public Notice. The plans and specifications for this project are incorporated by reference and are an enforceable part of the Certification. If you change your project, you must notify the Division and you may be required to submit a new application package with the appropriate fee. If the property is sold, the new owner must be given a copy of this Certification and is responsible for complying with all conditions. Any new owner must notify the Division and request the Certification be issued in their name. [15A NCAC 02H .0501 and .0502] 22. This certification grants permission to the director or an authorized representative of the Director, upon the presentation of proper credentials, to enter the property during normal business hours. [15A NCAC Q2H .0502(e)) Clemmons Town Center DWR # 16-1153 Individual Certification #WQC004084 Page 8 of 8 This approval to proceed with your proposed impacts or to conduct impacts to waters as depicted in your application shall expire upon expiration of the 404 or CAMA Permit. The conditions in effect on the date of issuance shall remain in effect for the life of the project, regardless of the expiration date of this Certification. [15A NCAC 02H .0507(d)(2) and 15A NCAC 02H.05061 Non-compliance with or violation of the conditions herein set forth may result in revocation of this Certification and may also result in criminal and/or civil penalties. This the 91" day of February 2017 Karen Higgins, Supervisor 401 & Buffer Permitting Branch KAH/s1h 3 3 CLEMMONS TOWN CENTER PROPERTY A� �0OF ADJOINING PROPERTY �cF o��LF ADJOINING PROPERTY Clemmons Town Center OUTLINE OF WETLAND/STREAM ClemmonsLNC2/8/2017 Combined Wetlands Impacts DOWN -GRADIENT for Clemmons Town Center & CLEMEMMONS TOWNN CENTER AREA Village Point Drive 61 LF OF STREAM 1,685 SF OF WETLANDS Prepared for: Hankins Land &Investment Company, LLC 16501 Northcross Drive Suite D Huntersville, NC 28078-5040 704-650-3964 Project #: 15-226 Prepared by: 7 stimmel'EE ni. 67 LANDSCAPE ARCHITECTURE CIVIL ENGINEERIRG LUNO PLANNING SCALE: 1" = 40' 40 0 40 North