Loading...
HomeMy WebLinkAbout20180061 Ver 1_17BP 7 C 12 Stormwater Management Plan_20180111k li�%I l�t'�n' North Carolina Department of Transportation , �,li)1'll]tivatPf Highway Stormwater Program ' _�. STORMWATER MANAGEMENT PLAN ��••-= ��r (Version 2.06; Released June 2016) FOR NCDOT PROJECTS WBS Element: 17BP.7.C.12 TIP No.: SF-402144 County(ies): Guilford Page 1 of 1 General Project Information WBS Element: 17BP.7.C.12 TIP Number: SF-402144 Project Type: Bridge Replacement Date: 11/15/2017 NCDOT Contact: Tim Powers, PE Contractor / Designer: Christopher R. Lewis, PE Address: 1584 Yanceyville St. Address: 1020 Birch Ridge Dr. Greensboro, NC 27415 Raleigh, NC 27610 Phone: 336 487-0000 Phone: 919 707-6714 Email: t owers ncdot. ov Email: crlewis2 ncdot. ov Cit ITown: Sedalia Count ies : Guilford River Basin(s): Cape Fear CAMA County? No Wetlands within Project Limits? No Pro'ect Description Project Length (lin. miles or feet): 0.046 Mi. Surrounding Land Use: Rural Proposed Pro'ect Existin Site Pro'ect Built-Upon Area ac. 0.1 ac. 0.1 ac. Typical Cross Section Description: 10' Travel Lanes with 10' grass shoulders 10' Travel Lanes with 10' grass shoulders Annual Avg Daily Traffic (veh/hr/day): Design/Future: 590 Year: 2016 Existing: 590 Year: 2016 General Project Narrative: W BS 17BP.7.C.12 is the replacement of 2@ 96" Corrugated Metal Pipes on SR 3093 (Old Julian Rd.) over Tributary to Big Alamance Creek. The proposed design calls for 1 (Description of Minimization of Water @ 14'-11" X 9'-10" Corrugated Aluminum Structural Plate Pipe Arch with headwall. The proposed structure will be buried 1' below the existing stream bed with 1' sills at the inlet Quality Impacts) and outlet. Bank stabilization is added at the inlet and outlet of the structure to stabilize the existing banks and promote vegitation growth along the banks. All natural, existing drainage patterns are maintained for the proposed roadway. The drainage area of this site, 1.9 Sq. Mi., does not warrant the need for a bridge structure and the anticipated maintenance costs would far exceed the structural plate arch at this site. No drainage structures are required. Waterbody Information Surface Water Body (1): Tributary to Big Alamance Creek NCDWR Stream Index No.: 16-19-(1) NCDWR Surface Water Classification for Water Body Primary Classification: Water Supply IV (WS-IV) Water Supply IV (WS-IV) Supplemental Classification: Nutrient Sensitive Waters (NSW) (NSW) Other Stream Classification: None Impairments: None Aquatic T&E Species? No Comments: NRTR Stream ID: Buffer Rules in Effect: Jordan Lake Project Includes Bridge Spanning Water Body? No Deck Drains Discharge Over Buffer? N/A Dissipator Pads Provided in Buffer? N/A Deck Drains Discharge Over Water Body? N/A (If yes, provide justification in the General Project Narrative) (If yes, describe in the General Project Narrative; if no, justify in the (If yes, provide justification in the General Project Narrative) General Project Narrative)