Loading...
HomeMy WebLinkAboutFlowers Solar Farm, LLC - SSW-Permit-LowDen-Supp-20090210-DEMLR-SPU Form SW401-Low Density-Rev.3-2/10/09 Page 2 of 5 Calculation: For uniform lot sizes: (SA: ft2 x DF: ) – (RA: ft2) – (OA: ft2) = BUA per Lot = ft2 (No of Lots: ) For non-uniform lot sizes: a. (SA: 1502385 ft2 x DF: .24) – (RA: 0 ft2) – (OA: 0 ft2) = Total allowable lot BUA = 360,572 ft2 b. Total BUA from lot listing: 57,447sf. b must be ≤ a III. DESIGN INFORMATION Complete the following table. If additional space is needed the information should be provided in the same format as Table 1 and attached to this form. Rainfall intensity data can be found in Appendix 8.03 of the State of North Carolina Erosion and Sediment Control Planning and Design Manual or at http://hdsc.nws.noaa.gov/hdsc/pfds/ Table 1. Swale design information based on the 10-year storm. Swale No. Drainage Area (ac) Impervious Area (ac) Grassed Area (ac) C Q (cfs) Slope (%) Vallow (fps) Vactual (fps) Flow Depth (ft) 1 3.28 0 3.28 .25 5.8 1.7 3.5 2.66 .63 2 2.24 0 2.24 .25 3.9 2.6 3.5 2.73 .51 3 1.91 .005 1.905 .25 3.4 1.5 3.5 2.12 .54 4 0.61 0 0.61 .25 1.1 2.0 3.5 1.73 .34 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20