Loading...
HomeMy WebLinkAboutNC0023876_Compliance Evlaution-Follow-up_20171127Water Resources Environmental Quality November 27, 2017 Mr. Robert Patterson, Water Resources Director City of Burlington PO Box 1358 Burlington, NC 27216-1358 Subject: Follow -Up Compliance Evaluation Inspection Report NPDES Permit NCO023876 South Burlington WWTP, Alamance County Dear Mr. Patterson: ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Interim Director RECEIVE®/DENR/DWR DEC 0 5 2017 Water Resources Permitting Section On November 21, 2017, Paul DiMatteo and Patrick Mitchell of the Division of Water Resources ("Division"), Winston-Salem Regional Office conducted a Follow -Up Compliance Evaluation Inspection of the above referenced wastewater treatment system. The presence and cooperation of Mr. Rick Asher was greatly appreciated. The purpose of this inspection was to further evaluate comments made during the previous inspection and summarized in our letter dated November 8, 2017. Observations are summarized below. Mercury Minimization Plan: A satisfactory plan was available for review during the inspection. Effluent Flow Measurement: The secondary device was verified to be in a nonstandard location, but this did not produce an error of greater than 10% when compared to a measurement taken from the standard location. We recommend continuing to monitor the flow from this meter to ensure that results are reported within the 10% error threshold. The South Burlington WWTP was found to be in compliance with NPDES Permit NC0023876. If you should have any questions, please do not hesitate to contact Paul DiMatteo at (336) 776-9691 or our office at (336) 776-9800. Sincerely, �',' herri V. Knight, P.E., Regional Supervisor Water Quality Regional Operations Section Winston-Salem Regional Office Division of Water Resources, NCDEQ Enclosures —Inspection Report and Summary CC: Rick Asher, by email WQS Winston-Salem Regional Office - Enforcement File NPDES Compliance/Enforcement Unit - Enforcement File Central Files <=r Nothjng Compares..._,,,, State of North Carolina I Environmental Quality 450 W Hanes Mill Road, Suite 300, Winston-Salem, North Carolina 27105 Phone 336-776-98001 FAX 336-776-9797 United States Environmental Protection Agency Form Approved EPA Washington, D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A• National Data System Coding (I a, PCs) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 I9 I 3 I NCO023876 I11 12 17/11/21 17 18 1,• 1 19 1 G 1 20I I 211 I I I I I I I I I 11 I 1 I l l l f l l l l l l l l l l l l l l l l I I 1 1 I I I 166 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ------Reserved---- 72 (ti ( 67 70 LJ I 1 71 L_j J L 73 �74 75 IJJ80 Section B. Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 1100AM 17!11!21 14/07/01 Southside WWTP 2471 Boy Wood Rd Exit Time/Date Permit Expiration Date Burlington NC 27215 11 45AM 17/11/21 19/06/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Richard Brian Asher/ORC/336-227-6261/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Robert C Patterson,PO Box 1358 Burlington NC 272161358//336-222-5130/3365706175 No Section C Areas Evaluated During Inspection (Check only those areas evaluated) Flow Measurement 0 Records/Reports Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Patrick Mitchell Division of Water Quality//336-776-96981 Paul DiMatteo�` WSRO WQ//336 691/ ' � Signature f Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete Page# NPDES yr/mo/day Inspection Type (Cont. 31 NCO023876 I11 12 17/11/21 17 18 i c i Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The purpose of this Inspection was to further evaluate comments made during the previous inspection and summarized in our letter dated November 8, 2017. Observations are summarized below. Mercury Minimization Plan: A satisfactory plan was available for review during the inspection. Effluent Flow Measurement. The secondary device was verified to be in a nonstandard location, but this did not produce an error of greater than 10% when compared to a measurement taken from the standard location. We recommend continuing to monitor the flow from this meter to ensure that results are reported within the 10% error threshold. Page# Permit- NCO023876 Inspection Date 11/21/2017 Owner - Facility- Southside WWTP Inspection Type: Compliance Evaluation Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? M ❑ ❑ ❑ Is flow meter calibrated annually? M ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment: Took measurements of the flume: Width: 2 ft Ha (location of measurement point, from table): 3 ft 4 In Actual Doppler Device Location: — 4 ft 3 in Flow was fairly turbulent at the time of the measurement. Estimated a head of 1.00 feet -> flow of 5.2 mqd. SCADA showed —5.4 mqd, giving an error of 3.8% for this reading, which is within the 10% threshold. Also retained a copy of a note from the calibration company which said that he doubted the difference in measurement location would equate to a >10% error. It would be interesting to determine the actual difference in measurement between Ha and the doppler device location, or to measure again when the flow through the flume was less turbulent Page# 3