HomeMy WebLinkAboutNC0025861_Compliance Inspection_20171129Water Resources ENVIRONMHNI AL OUALI TY November 29, 2017 Mr. Kevin Krouse Public Works Director 101 West First Street Lowell, NC 28098 ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Interim Director 0 6 2011 Water Resources on Fernntting Subject: Compliance Inspection Lowell WWTP NPDES Permit No. NCO025861 Gaston County Dear Mr. Krouse: Enclosed is a copy of the Compliance Inspection report for the inspection conducted at the subject facility on November 27, 2017, by Ori Tuvia. Daniel Dougherty's cooperation during the site visit was much appreciated. Please advise the staff involved with this NPDES Permit by forwarding a copy of the enclosed report. The main area of concern observed during the inspection was that there was evidence of stormwater erosion around the influent pump station. Stormwater control measures (such as riprap) should be put along the side and entrance to the influent pump station to prevent erosion damage and to prevent stormwater from flowing into the pump station wet well. Additionally, the clarifier drive unit arm seemed to not remove all the surface scum. The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact Ori Tuvia at (704) 235-2190, or at ori.tuvia@ncdenr.gov. Cc: NPDES Unit MRO Files Ron Haynes (E -Copy) Sincerely, Ori Tuvia, Environmental Engineer Mooresville Regional Office Division of Water Resources, DEQ Mooresville Regional Office I nratinn sin Fact rantar Ava qm 4(11 Mnnraavilla Nr` 98119 United States Environmental Protection Agency Form Approved EPA Washington, D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A National Data System Coding (i e, PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 1 3 I NCO025861 I11 12 17/11/27 17 18 LCJ 19 I c I 20L] 211 1 1 1 1 1 111 111 1 11 11 1 11 1 111 1 1 11111 1111111 ii i i r6 I Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 67 10 70 Jd J 71 Iti I 72 L N 731 I 174 75III 80 LJ LJ LJ—I Section B. Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 10 55AM 17/11/27 15/02/01 Lowell WWTP NCSR 2380 Exit Time/Date Permit Expiration Date Lowell NC 28098 1210PM 17/11/27 20/01/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Daniel James Dougherty/ORC/704-477-5514/ Name, Address of Responsible OfficiaUTiUe/Phone and Fax Number Contacted Daniel J Dougherty,Saxony Or Lowell NC 28098/ORC/704-477-5514/ No Section C Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Recelving Waters Laboratory , Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date On A Tuvia ` --I MRO WQ//704-663-1699/ Z' Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date W Corey Basinger MRO WQ//704-235-2194/ EPA For 3560-3 (Rev 9-94) Previous editions are obsolete Page# NPDES yr/mo/day 31 NCO025861 I11 12 17/11/27 17 Inspection Type 18 ICI Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) 1 9 Page# 2 Permit N00025861 Owner -Facility LowellWWTP Inspection Date 11/27/2017 Inspection Type Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ M ❑ application? 0 ❑ ❑ ❑ Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? M ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ❑ ❑ ❑ Comment The subiect permit expires on 1/31/2020. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? M ❑ ❑ ❑ Is all required Information readily available, complete and current? 0 ❑ ❑ ❑ Are all records maintained for 3 years (lab reg required 5 years)? 0 ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? M ❑ ❑ ❑ Dates, times and location of sampling COCs, Calibration lops and ORC logs were reviewed for the period September 2016 Name of Individual performing the sampling through August 2017 Results of analysis and calibration Dates of analysis Name of person performing analyses Transported CDCs Are DMRs complete do they include all permit parameters? 0 ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? M ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ M ❑ on each shift? Is the ORC visitation log available and current? 0 ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? M ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? 0 ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? 0 ❑ ❑ ❑ Comment: The records reviewed during the inspection were organized and well maintained. DMRs, COCs, Calibration lops and ORC logs were reviewed for the period September 2016 through August 2017 Laboratory Yes No NA NE Page# 3 Permit NCO025861 Owner -Facility Lowell WWTP Inspection Date 11/27/2017 Inspection Type Compliance Evaluation Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? ❑ ❑ ❑ # Is the facility using a contract lab? M ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ Celsius)? N ❑ Incubator (Fecal Coliform) set to 44 5 degrees Celsius+/- 0 2 degrees? ❑ ❑ 0 ❑ Incubator (BOD) set to 20 0 degrees Celsius +/-1 0 degrees? ❑ ❑ 0 ❑ Comment: On-site field analyses (dissolved oxygen DH temperature, total residual chlorine) are # Is proper temperature set for sample storage (kept at less than or equal to 6 0 degrees 0 performed under the City's field laboratory certification #5082 PAR Labs. Inc. has been ❑ contracted to perform influent and effluent analyses. Meritech Labs, Inc has also been Celsius)? contracted to perform the chronic toxicity analyses. The laboratory instrumentation used for field analyses appeared to be properly calibrated/verified and documented. Is sampling performed according to the permit? M Influent Sampling Yes No NA NE # Is composite sampling flow proportional? 0 ❑ ❑ ❑ Is sample collected above side streams? M ❑ ❑ ❑ Is proper volume collected? N ❑ ❑ ❑ Is the tubing clean? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6 0 degrees 0 ❑ ❑ ❑ Celsius)? Is sampling performed according to the permit? M ❑ ❑ ❑ Comment. The subiect permit requires composite biochemical oxygen demand (BOD) and TSS influent samples Aliquot pulled durinq the inspection was 155 ml. pulled during the Effluent Sampling Yes No NA NE Is composite sampling flow proportional? 0 ❑ ❑ ❑ Is sample collected below all treatment units? M ❑ ❑ ❑ Is proper volume collected? M ❑ ❑ ❑ Is the tubing clean? N ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees 0 ❑ ❑ ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type 0 ❑ ❑ ❑ representative)? Comment- The subject permit requires composite and grab effluent samples Aliquot pulled during the inspection was 170 ml. Operations & Maintenance Yes No NA NE Page# 4 Permit NCO025861 Owner -Facility Lowell wwTP Inspection Date 11/27/2017 Inspection Type Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex- MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The facility aDDeared to be Droperly operated and well maintained At the time of the inspection flow meter chart was broken and was in the process of being repaired. At the time of the inspection there was evidence of stormwater erosion around the influent pump station. Bar Screens Yes No NA NE Type of bar screen Yes No NA NE # Is flow meter used for reporting? ❑ 0 a Manual ❑ Is flow meter calibrated annually? 0 ❑ b.Mechanical ❑ Is the flow meter operational? N ❑ Are the bars adequately screening debris? ❑ ❑ ❑ ❑ Is the screen free of excessive debris? ❑ ❑ ❑ ❑ Is disposal of screening in compliance? 0 ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: The facility is equipped with mechancial and manual bar screens (coarse) ❑ Flow Measurement - Influent Yes No NA NE # Is flow meter used for reporting? ❑ 0 ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? N ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? 0 ❑ ❑ ❑ Comment: Flow meter is calibrated/verified twice per year and was last calibrated/verified on 9/13/2017 E by Ken Nash Company. ❑ ❑ Is SCADA telemetry available and operational? ❑ Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? 0 ❑ ❑ ❑ Is the wet well free of excessive grease? E ❑ ❑ ❑ Are all pumps present? 0 ❑ ❑ ❑ Are all pumps operable? N ❑ ❑ ❑ Are float controls operable? E ❑ ❑ ❑ Is SCADA telemetry available and operational? ❑ ❑ 0 ❑ Is audible and visual alarm available and operational? ❑ ❑ 0 ❑ Page# 5 E Permit NCO025661 Owner - Facility Lowell WWTP Inspection Date 11/27/2017 Inspection Type Compliance Evaluation Pump Station - Influent Yes No NA NE Comment: SCADA is not available_ however, there is an auto dialer to contact the ORC in caste of power outage At the time of the inspection there was evidence of stormwater erosion, stormwater control measures (such as norap) should be put alona the side and entrance to the influent pump station to prevent erosion damage and stormwater flowing into the pump station wet well. Aeration Basins Mode of operation Type of aeration system Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment processs? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Is the DO level acceptable?(1 0 to 3 0 mg/I) Yes No NA NE Diffused Yes No NA NE Is the clarifier free of black and odorous wastewater? E ❑ ❑ ❑ ❑ ❑ E ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ E ❑ ❑ ❑ ■ ❑ ❑ ❑ Comment: The facility uses the contact stabilization treatment process. Sodium Hydroxide is added. Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? N ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? 0 ❑ ❑ ❑ Are weirs level? 0 ❑ ❑ ❑ Is the site free of weir blockage? 0 ❑ ❑ ❑ Is the site free of evidence of short-circuiting? 0 ❑ ❑ ❑ Is scum removal adequate? E ❑ ❑ ❑ Is the site free of excessive floating sludge? 0 ❑ ❑ ❑ Is the drive unit operational? E ❑ ❑ ❑ Is the return rate acceptable (low turbulence)? 0 ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? 0 ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately'/ of the sidewall depth) E ❑ ❑ ❑ Comment: The clarfier drive unit arm seemed to not remove all the surface scum. Disinfection -Gas Yes No NA NE Are cylinders secured adequately? E ❑ ❑ ❑ Are cylinders protected from direct sunlight? N ❑ ❑ ❑ Page# 6 Permit NCO025861 Owner -Facility LoweIIWWTP Yes No NA NE Type of system ? Gas ❑ Inspection Date 11/27/2017 Inspection Type Compliance Evaluation ❑ Is the feed ratio proportional to chlorine amount (1 to 1)? E ❑ Disinfection -Gas Yes No NA NE Is there adequate reserve supply of disinfectant? E ❑ ❑ ❑ Is the level of chlorine residual acceptable? E ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? N ❑ ❑ ❑ Does the Stationary Source have more than 2500 lbs of Chlorine (CAS No 7782-50-5)? ❑ 0 ❑ ❑ If yes, then is there a Risk Management Plan on site? ❑ ❑ 0 ❑ If yes, then what is the EPA twelve digit ID Number? (1000- - ) If yes, then when was the RMP last updated? Comment: About 900 lbs. of chlorine stored on site. De -chlorination Yes No NA NE Type of system ? Gas ❑ ❑ ❑ Is the feed ratio proportional to chlorine amount (1 to 1)? E ❑ ❑ ❑ Is storage appropriate for cylinders? 0 ❑ ❑ ❑ # Is de -chlorination substance stored away from chlorine containers? ❑ 0 ❑ ❑ Are the tablets the proper size and type? ❑ ❑ 0 ❑ Comment: The chlorination and dechlorination cylinders are stored together Inside a building equipped with ventilation and a leakage detection system. Are tablet de -chlorinators operational? ❑ ❑ ❑ Number of tubes In use? Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? E ❑ ❑ ❑ Is the flow meter operational? N ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ N ❑ ❑ Comment: Flowmeter is calibrated/verified_ twice per year and was last calibrated/verified on 9/13/2017 by Ken Nash Company. At the time of the inspection flow meter chart recorder was broken and was in the process of being repaired. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ Page# 7 Permit NC0025861 Owner -Facility LoweIIWWTP Inspection Date 11/27/2017 Inspection Type Compliance Evaluation Effluent Pipe Yes No NA NE ,If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment. The effluent appeared clear with no negative impact to the stream Aerobic Digester Yes No NA NE Is the capacity adequate? 0 ❑ ❑ ❑ Is the mixing adequate? M ❑ ❑ ❑ Is the site free of excessive foaming In the tank? M ❑ ❑ ❑ # Is the odor acceptable? 0 ❑ ❑ ❑ # Is tankage available for properly waste sludge? 0 ❑ ❑ ❑ Comment. Dryinq Beds Yes No NA NE Is there adequate drying bed space? M ❑ ❑ ❑ Is the sludge distribution on drying beds appropriate? M ❑ ❑ ❑ Are the drying beds free of vegetation? M ❑ ❑ ❑ # Is the site free of dry sludge remaining in beds? M ❑ ❑ ❑ Is the site free of stockpiled sludge? N ❑ ❑ ❑ Is the filtrate from sludge drying beds returned to the font of the plant? M ❑ ❑ ❑ # Is the sludge disposed of through county landfill? N ❑ ❑ ❑ # Is the sludge land applied? M ❑ ❑ ❑ (Vacuum filters) Is polymer mixing adequate? 0 ❑ ❑ ❑ Comment: Dewatered sludge Is transported to landfill Standby Power Yes No NA NE Is automatically activated standby power available? M ❑ ❑ ❑ Is the generator tested by interrupting primary power source? M ❑ ❑ ❑ Is the generator tested under load? 0 ❑ ❑ ❑ Was generator tested & operational during the Inspection? ❑ ❑ ❑ M Do the generator(s) have adequate capacity to operate the entire wastewater site? M ❑ ❑ ❑ Is there an emergency agreement with a fuel vendor for extended run on back-up power? 0 ❑ ❑ ❑ Is the generator fuel level monitored? M ❑ ❑ ❑ Comment. The standby generator Is tested (automatically) once per week. The City/Permittee contracts a company to service the generator twice per year. Page# 8 ,a Water Resources Environmental Quality November 27, 2017 Mr. Robert Patterson, Water Resources Director City of Burlington PO Box 1358 Burlington, NC 27216-1358 Subject: Compliance Evaluation Inspection Report NPDES Permit NCO023868 East Burlington WWTP, Alamance County Dear Mr. Patterson: ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Interim Director RECEIVED/DENR/DWR DEC 0 5 2017 Water Resources Permitting Section On November 21, 2017, Paul DiMatteo of the Division of Water Resources ("Division"), Winston-Salem Regional Office conducted a Compliance Evaluation Inspection of the above referenced wastewater treatment system. The presence and cooperation of Mr. Darrin Allred was greatly appreciated. This type of inspection consists of two basic parts: an on-site inspection of the facility and a review of facility files and self-monitoring data. Observations from each area of the inspection are summarized below. Site Review 1. Permit The current permit became effective on July 1, 2014 and expires on June 30, 2019. A copy of the current permit was available for review. Permitted components include a 4 million gallon aerated equalization basin, primary and secondary clarifiers, biological phosphorus reduction, sand filtration, and gas chlorination. 2. Facility Site Review The facility was as described in the permit. At the time of inspection, one secondary clarifier was down for routine maintenance. It was noted during the previous inspection that the plant planned to replace the gas chlorine disinfection system with liquid chlorine; however, Mr. Allred said that the details had not yet been finalized. The backup power generator is tested under load every month. An Authorization to Construct was recently issued for a dewatering press and related systems. Mr. Allred said that the installation was progressing well. --` 7',—Nathing Compares_-_. State of North Carolina I Environmental Quality 450 W Hanes Mill Road, Suite 300, Winston-Salem, North Carolina 27105 Phone. 336-776-98001 FAX 336-776-9797 3. Operation and Maintenance Darrin Allred is the current Operator in Responsible Charge, and Eric Davis and Kenneth Timson are backup ORCs. All operators are properly designated and hold the correct credentials. The operators use the Hach Water Information Management Systems (WIMS) database to track trends in the treatment process and integrate reporting and documentation, and the Hach JOB Cal system to track all preventative and repair work at the plant. Mr. Allred also keeps a paper notebook documenting his daily plant visitations. 4. Flow Measurement Effluent flow is measured with an ultrasonic secondary device set above a 2 foot Parshall flume. The calibration is checked quarterly by Instrument Specialists, Inc. 5. Effluent/Receiving Waters The effluent is discharged to the Haw River in the Cape Fear River Basin. Effluent appeared clear with no visible solids. In -stream monitoring requirements have been waived as long as the City of Burlington remains a member of the Upper Cape Fear River Basin Association. Documentation Review 6. Records/Reports Discharge Monitoring Reports (DMRs) and lab data are maintained according to the permit. DMRs include all permit parameters. Copies of DMRs, operator visitation logs, daily operation sheets, maintenance reports, lab reports and Chain -of -Custody forms were available for review during the inspection. 7. Self -Monitoring Program A review of DMRs from September, 2016 through September, 2017 showed no violations, and a comparison of submitted DMR data with bench records showed no errors or concerns. 8. Laboratory All parameters are analyzed by the City of Burlington Wastewater Treatment Plant Laboratory under certification #188, except for headworks, toxicity and the effluent pollutant scan, which are analyzed by Meritech under certification #165. When a separate lab analyzes headworks samples, they also analyze all other samples collected that day. Operators of the plant analyze field parameters under the City of Burlington WWTP Lab's certification. Copies of all laboratory documentation are kept at the Burlington WWTP Lab. Effluent composite sampler is flow proportional. During the inspection, the thermometer inside the sampler read 0.5°C at the effluent and 2.5'C at the influent. Sampling and field parameter measurement procedures appeared acceptable. 9. Sludge Handling Disposal Lime stabilized residuals are land applied according to Division of Water Resources Permit WQ0000520. A portion of residuals stabilized by the Zimpro process are disposed of via transport to the landfill. Hauling records for each type of disposal were available at the time of inspection. If you should have any questions, please do not hesitate to contact Paul DiMatteo at (336) 776-9691 or our office at (336) 776-9800. Sincerely, �6"/Sherri V. Knight, P.E., Regional Supervisor Water Quality Regional Operations Section Winston-Salem Regional Office Division of Water Resources, NCDEQ Enclosures —Inspection Report and Summary CC: Darrin Allred, by email WQS Winston-Salem Regional Office - Enforcement File NPDES Compliance/Enforcement Unit - Enforcement File Central Files United States Environmental Protection Agency Form Approved EPA Washington, D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires B-31-98 Section A National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 E j 2 15 1 3 I NCO023868 111 12 17/11/21 17 181.-1 191 c I 201 I 211 1 1 1 I I I I I I 11 I I I I I I I I I I I I I I I I I I I I I I I 11 I I I I jJ6 -Reserved — Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA ---Reserved-- 671 72 Lti 731 I 74 75 1 1 1 1 1 80 67 70 J 71 itJ Section B Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 12 30PM 17/11/21 14/07/01 Eastside WWTP Exit Time/Date Permit Expiration Date 225 Stone Quarry Rd Burlington NC 27216 03 45PM 17/11/21 19/06130 Name(s) of Onsite Representative(s)/Tifies(s)/Phone and Fax Number(s) Other Facility Data Darnn Lee Allred/ORC/336-558-8520/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Robert C Patterson,PO Box 1358 Burlington NC No 272161358//336-222-5130/3365706175 Section C Areas Evaluated During Inspection (Check only those areas evaluated) Permit E Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program E Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Laboratory Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date PauliMatteo WSRO WQ//336-776-9691/ X171017 Signature of anagement Q A ReviewerAgency/Office/Phone and Fax Numbers Date � ,' 67 12117 1/ G ` EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete Page# NPDES yr/mo/day Inspection Type (Cont 31 NCO023868 111 121 17/11/21 1 17 18 ICI Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Site Review 1. Permit The current permit became effective on July 1, 2014 and expires on June 30, 2019. A copy of the current permit was available for review. Permitted components include a 4 million gallon aerated equalization basin, primary and secondary clarifiers, biological phosphorus reduction, sand filtration, and gas chlorination. 2. Facility Site Review The facility was as described in the permit. At the time of inspection, one secondary clarifier was down for routine maintenance It was noted during the previous inspection that the plant planned to replace the gas chlorine disinfection system with liquid chlorine; however, Mr Allred said that the details had not yet been finalized. The backup power generator is tested under load every month. An Authorization to Construct was recently issued for a dewatering press and related systems. Mr. Allred said that the Installation was progressing well. 3. Operation and Maintenance Daren Allred is the current Operator in Responsible Charge, and Eric Davis and Kenneth Timson are backup ORCs. All operators are properly designated and hold the correct credentials. The operators use the Hach Water Information Management Systems (WIMS) database to track trends in the treatment process and integrate reporting and documentation, and the Hach JOB Cal system to track all preventative and repair work at the plant. Mr. Allred also keeps a paper notebook documenting his daily plant visitations 4. Flow Measurement Effluent flow is measured with an ultrasonic secondary device set above a 2 foot Parshall flume. The calibration is checked quarterly by Instrument Specialists, Inc. 5 Effluent/Receiving Waters The effluent is discharged to the Haw River in the Cape Fear River Basin. Effluent appeared clear with no visible solids. In -stream monitoring requirements have been waived as long as the City of Burlington remains a member of the Upper Cape Fear River Basin Association. Documentation Review 6 Records/Reports Discharge Monitoring Reports (DMRs) and lab data are maintained according to the permit. DMRs include all permit parameters. Copies of DMRs, operator visitation logs, daily operation sheets, maintenance reports, lab reports and Chain -of -Custody forms were available for review during the inspection. 7. Self -Monitoring Program A review of DMRs from September, 2016 through September, 2017 showed no violations, and a comparison of submitted DMR data with bench records showed no errors or concerns. 8. Laboratory All parameters are analyzed by the City of Burlington Wastewater Treatment Plant Laboratory under certification #188, except for headworks, toxicity and the effluent pollutant scan, which are analyzed by Meritech under certification #165. When a separate lab analyzes headworks samples, they also analyze all other samples collected that day Operators of the plant analyze field parameters under the City of Burlington WWTP Lab's certification. Copies of all laboratory documentation are kept at the Burlington WWTP Lab. Effluent composite sampler is flow proportional. During the inspection, the thermometer inside the sampler read 0 5°C at the effluent and 2.5°C at the influent. Sampling and field parameter measurement procedures appeared acceptable. 9 Sludge Handling Disposal Lime stabilized residuals are land applied according to Division of Water Resources Permit WQ0000520 A portion of residuals stabilized by the Zimpro process are disposed of via transport to Page# Permit NC0023868 Owner - Facility: Eastside WWTP Inspection Date. 11/21/2017 InspectionType, Compliance Evaluation the landfill Hauling records for each type of disposal were available at the time of inspection Page# Permit, NCO023868 Owner - Facility: Eastside WWTP Inspection Date: 11/21/2017 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex MLSS, MCRT, Settleable 0 ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ M ❑ application? ❑ ❑ ❑ ❑ Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? M ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? M ❑ ❑ ❑ Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ❑ ❑ ❑ ❑ Is all required information readily available, complete and current? ❑ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ❑ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ❑ ❑ ❑ ❑ Is the chain -of -custody complete? M ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported CDCs Are DMRs complete- do they include all permit parameters? ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ ❑ on each shift? Is the ORC visitation log available and current? 0 ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? 0 ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? M ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑ Page# 4 Permit NC0023868 Owner - Facility. Eastside WWTP Inspection Date: 11/21/2017 Inspection Type- Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? 0 ❑ ❑ ❑ Comment Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ ❑ Comment: Step aeration after dechlorination, before discharge. Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? ❑ ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ M ❑ Comment. 2 ft Parshall flume w/ doppler device. Checked every 3 months by ISI. Chemical Feed Yes No NA NE Is containment adequate? M ❑ ❑ ❑ Is storage adequate? 0 ❑ ❑ ❑ Are backup pumps available? ❑ ❑ ❑ 0 Is the site free of excessive leaking? M ❑ ❑ ❑ Comment Aerobic Digester Yes No NA NE Is the capacity adequate? 0 ❑ ❑ ❑ Is the mixing adequate? M ❑ ❑ ❑ Is the site free of excessive foaming in the tank? 0 ❑ ❑ ❑ # Is the odor acceptable? M ❑ ❑ ❑ # Is tankage available for properly waste sludge? M ❑ ❑ ❑ Comment: Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? 0 ❑ ❑ ❑ Page# 5 Permit: NC0023868 Inspection Date: 11/21/2017 Pump Station - Influent Is the wet well free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Is SCADA telemetry available and operational? Is audible and visual alarm available and operational? Comment - Bar Screens Type of bar screen a.Manual b Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment. Manual bar screen available as backup Grit Removal Type of grit removal a.Manual b Mechanical Is the grit free of excessive organic matter? Is the grit free of excessive odor? # Is disposal of grit in compliance? Comment Owner - Facility. Eastside wwTP Inspection Type. Compliance Evaluation Equalization Basins Is the basin aerated? Is the basin free of bypass lines or structures to the natural environment? Is the basin free of excessive grease? Are all pumps present? Are all pumps operable? Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ Yes No NA NE El ■ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Yes No NA NE ■ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Page# 6 Permit- NCO023868 Owner -Facility: Eastside WWTP Is the clarifier free of black and odorous wastewater? M ❑ Inspection Date- 11/21/2017 Inspection Type Compliance Evaluation Is the site free of excessive buildup of solids in center well of circular clarifier? M ❑ Equalization Basins Yes No NA NE Are float controls operable? 0 ❑ ❑ ❑ Are audible and visual alarms operable? ❑ ❑ ❑ 0 # Is basin size/volume adequate? 0 ❑ ❑ ❑ Comment: Primary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? M ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? M ❑ ❑ ❑ Are weirs level? N ❑ ❑ ❑ Is the site free of weir blockage? 0 ❑ ❑ ❑ Is the site free of evidence of short-circuiting? N ❑ ❑ ❑ Is scum removal adequate? 0 ❑ ❑ ❑ Is the site free of excessive floating sludge? 0 ❑ ❑ ❑ Is the drive unit operational? 0 ❑ ❑ ❑ Is the sludge blanket level acceptable? ❑ ❑ ❑ 0 Is the sludge blanket level acceptable? (Approximately 1/4 of the sidewall depth) ❑ ❑ ❑ M Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? M ❑ ❑ ❑ Are weirs level? ❑ ❑ ❑ Is the site free of weir blockage? ❑ ❑ ❑ Is the site free of evidence of short-circuiting? ❑ ❑ ❑ Is scum removal adequate? ❑ ❑ ❑ Is the site free of excessive floating sludge? 0 ❑ ❑ ❑ Is the drive unit operational? ❑ ❑ ❑ Is the return rate acceptable (low turbulence)? ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately % of the sidewall depth) ❑ ❑ ❑ Comment Per ORC try to keep sludge blanket to 0 5 ft or less for better nutrient removal. Aeration Basins Yes No NA NE Page# 7 Permit NCO023868 Inspection Date• 11/21/2017 Aeration Basins Mode of operation Type of aeration system Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/1) Owner - Facility Eastside WWTP Inspection Type: Compliance Evaluation Comment- At effluent end, process control DO probe read 1.73 mg/L Nutrient Removal # Is total nitrogen removal required? # Is total phosphorous removal required? Type # Is chemical feed required to sustain process? Is nutrient removal process operating properly? Comment Filtration (Hi-gh Rate Tertiary) Type of operation - Is the filter media present? Is the filter surface free of clogging? Is the filter free of growth? Is the air scour operational? Is the scouring acceptable? Is the clear well free of excessive solids and filter media' Comment: Not evaluated during Inspection due to time constraints. Disinfection -Gas Are cylinders secured adequately? Are cylinders protected from direct sunlight? Is there adequate reserve supply of disinfectant? Yes No NA NE Ext. Air Diffused ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ N ❑ 1:111 ■ ❑ 1:111 • ❑ ❑ ❑ • ❑ 1:11:1 • ❑ ❑ ❑ Yes No NA NE [Is ❑❑ ■ ❑ ❑ ❑ Biological Yes No NA NE Down flow ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ N ❑ ❑ ❑ ■ ❑ ❑ ❑ N ❑ ❑ ❑ ■ Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Page# 8 6 #a6ed ❑ ❑ ❑ M Lleuoijejedo sdwnd eiV ❑ ❑ ❑ ■ /_aoeld w sdwnd eiV 3N VN ON saA SVAkS"-s wnd lgluow palsal Iuewwoo ❑ ❑ ❑ 0 IpaJo}luow lana) lon; jo;ejeua6 eq; sl ❑ ❑ ❑ 0 Z jemod do-Noeq uo uni papua}xa Jo; Jopuan lanj a gjim juawaoibe loue6jewe ue eiagl sl ❑ ❑ ❑ 0 4,91is jalennalseM an}ue aqj ejejedo of lgtaedeo ejenbape aneq (s)Jo}eJau96 aq; oQ ❑ ❑ ❑ e,uoi}oadsul eq; 6uunp leuogejedo +g palsal jolejaua6 seM ❑ ❑ ❑ 0 epeol japun pa}sa; jolejeua6 eq} sl ❑ ❑ ❑ M Laoinos jaMod lvewud 6ul;dnijejul Aq pa;sa} jolejaua6 eq; sl ❑ El 11e,9lgeliene jamod Agpue}s pa;enl}ae Alleol}ewo}ne sl 3N VN ON saA JaNwd Aqpu9FS ;uewwoo e,asn ui segnj jo jegwnN ❑ 0 ❑ ❑ Zleuogejedo sio}euuolgo-ap jelge; eiV ❑ ❑ ❑ 0 ead/4 pue ezis jadoid eqj slalge} eq; eiV quawwoo ❑ ❑ ❑ m LSAauleJuoa auuolga waJ A13ME paJo;s e3ue;sgns uoi}euuolgo-ap sl # ❑ ❑ ❑ 0 esJ8puljA3 Jo,} eleudadde 96ejols sl ❑ El 11e,(L o; L) }unowe awJolga of leumpodoid oijej peal aql sl ❑ ❑ SEE) a wa}sAs;o ads _L 3N VN ON saA UOI;BUIJO143-a(] •alnpegos a uo pauealo pue umop unnelp sl .lagwego }oe}uoo euuolgo eq} Jo fed }uawwOO e,pa}epdn Isel dMI aq} seM uagM uaq) 'sa/(;I 3N (-- -000 L) cjagwnN QI 1161p anlann} yd3 aq} si 18gm uaq; 'say(1I ❑ ❑ ❑ M 01ls uo ueld luaw96eueW WI l a ajaq; si uagl 'saA 11 ❑ ❑ ❑ 1,(9-09-ULL 'oN SVO) euuolgo do sql 009Z ueq; avow aneq aomoS /ueuoile;S eq; saoa ❑ ❑ ❑ e,uoljeuuolgo-9p o; joljd lenplsaj auuolgo eiagj sl ❑ ❑ ❑ M 4dnplinq e6pnls .lo 'q;Ma6 jo oeil jegwego joe}uoo eq; sl M ❑ ❑ ❑ 4alge;d93oe lenpisei auuolga 10 lanai eq; sI 3N VN ON sGA sed-UOI;Oa;UISIQ uogenlen3 aouegdwoo adlll uol;oedsul LLOZ/6Z/l l :a;ea uol;aadsul d1MM apis;sea '��Pae3 - Jeumo 899£ZOODN 31wJad Permit: NCO023868 Owner -Facility. EastsideWWTP Inspection Date. 11/21/2017 Inspection Type- Compliance Evaluation Pumps -RAS -WAS Yes No NA NE Are there adequate spare parts and supplies on site? 0 ❑ ❑ ❑ Comment Laboratory E Yes No NA NE Are field parameters performed by certified personnel or laboratory? N ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? 0 ❑ ❑ ❑ # Is the facility using a contract lab? ❑ M ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees 0 ❑ ❑ ❑ Celsius)? Is sample collected above side streams? 0 ❑ ❑ Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? M ❑ ❑ ❑ Incubator (BOD) set to 20 0 degrees Celsius +/- 10 degrees? 0 ❑ ❑ ❑ Comment Primary laboratory Inspected 10125/2017. BOD Incubator 19 5 C: Fecal incubator 44.5 C (According to their thermometers). Field parameters are measured on site under Burlington Yes No NA NE Is composite sampling flow proportional? WWTP's certification. On-site calibration records appeared acceptable. Thermometers ❑ ❑ ❑ were last calibrated in October 2016 - Mr Allred said that they were in the process of having ❑ ❑ the main laboratory conduct the calibration. Is proper volume collected? 0 ❑ ❑ Influent Sampling Yes No NA NE # Is composite sampling flow proportional? M ❑ ❑ ❑ Is sample collected above side streams? 0 ❑ ❑ ❑ Is proper volume collected? ❑ ❑ ❑ Is the tubing clean? ❑ ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6 0 degrees ❑ ❑ ❑ Celsius)? Is sampling performed according to the permit? M ❑ ❑ ❑ Comment: Refrigerator 2.5 C. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ ❑ Is sample collected below all treatment units? ❑ ❑ ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? N ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees 0 ❑ ❑ ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type M ❑ ❑ ❑ representative)? Page# 10 Permit NCO023868 Inspection Date 11/2112017 Effluent Sampling Comment. Refrigerator 0.5 C Owner • Facility Eastside WWTP Inspection Type. Compliance Evaluation Yes No NA NE Page# 11