HomeMy WebLinkAboutNC0025861_Compliance Inspection_20171129Water Resources
ENVIRONMHNI AL OUALI TY
November 29, 2017
Mr. Kevin Krouse
Public Works Director
101 West First Street
Lowell, NC 28098
ROY COOPER
Governor
MICHAEL S. REGAN
Secretary
LINDA CULPEPPER
Interim Director
0 6 2011
Water Resources on
Fernntting
Subject: Compliance Inspection
Lowell WWTP
NPDES Permit No. NCO025861
Gaston County
Dear Mr. Krouse:
Enclosed is a copy of the Compliance Inspection report for the inspection conducted at the
subject facility on November 27, 2017, by Ori Tuvia. Daniel Dougherty's cooperation during the site
visit was much appreciated. Please advise the staff involved with this NPDES Permit by forwarding a
copy of the enclosed report.
The main area of concern observed during the inspection was that there was evidence of
stormwater erosion around the influent pump station. Stormwater control measures (such as
riprap) should be put along the side and entrance to the influent pump station to prevent erosion
damage and to prevent stormwater from flowing into the pump station wet well. Additionally, the
clarifier drive unit arm seemed to not remove all the surface scum.
The report should be self-explanatory; however, should you have any questions concerning
this report, please do not hesitate to contact Ori Tuvia at (704) 235-2190, or at
ori.tuvia@ncdenr.gov.
Cc: NPDES Unit
MRO Files
Ron Haynes (E -Copy)
Sincerely,
Ori Tuvia, Environmental Engineer
Mooresville Regional Office
Division of Water Resources, DEQ
Mooresville Regional Office
I nratinn sin Fact rantar Ava qm 4(11 Mnnraavilla Nr` 98119
United States Environmental Protection Agency
Form Approved
EPA Washington, D C 20460
OMB No 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A National Data System Coding (i e, PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN 1 2 15 1 3 I NCO025861 I11 12 17/11/27 17 18 LCJ 19 I c I 20L]
211 1 1 1 1 1 111 111 1 11 11 1 11 1 111 1 1 11111 1111111 ii i i r6
I
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
67 10 70 Jd J 71 Iti I 72 L N 731 I 174 75III 80
LJ LJ LJ—I
Section B. Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES oermit Number)
10 55AM 17/11/27
15/02/01
Lowell WWTP
NCSR 2380
Exit Time/Date
Permit Expiration Date
Lowell NC 28098
1210PM 17/11/27
20/01/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Daniel James Dougherty/ORC/704-477-5514/
Name, Address of Responsible OfficiaUTiUe/Phone and Fax Number
Contacted
Daniel J Dougherty,Saxony Or Lowell NC 28098/ORC/704-477-5514/
No
Section C Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenance Records/Reports
Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Recelving Waters
Laboratory ,
Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
On A Tuvia ` --I MRO WQ//704-663-1699/
Z'
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
W Corey Basinger MRO WQ//704-235-2194/
EPA For 3560-3 (Rev 9-94) Previous editions are obsolete
Page#
NPDES
yr/mo/day
31 NCO025861 I11 12 17/11/27 17
Inspection Type
18 ICI
Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
1
9
Page# 2
Permit N00025861 Owner -Facility LowellWWTP
Inspection Date 11/27/2017 Inspection Type Compliance Evaluation
Permit
Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
❑
❑
M
❑
application?
0
❑
❑
❑
Is the facility as described in the permit?
0
❑
❑
❑
# Are there any special conditions for the permit?
❑
0
❑
❑
Is access to the plant site restricted to the general public?
M
❑
❑
❑
Is the inspector granted access to all areas for inspection?
❑
❑
❑
Comment The subiect permit expires on 1/31/2020.
Record Keeping
Yes No NA NE
Are records kept and maintained as required by the permit?
M
❑
❑
❑
Is all required Information readily available, complete and current?
0
❑
❑
❑
Are all records maintained for 3 years (lab reg required 5 years)?
0
❑
❑
❑
Are analytical results consistent with data reported on DMRs?
0
❑
❑
❑
Is the chain -of -custody complete?
M
❑
❑
❑
Dates, times and location of sampling
COCs, Calibration lops and ORC logs were reviewed for the period September 2016
Name of Individual performing the sampling
through August 2017
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported CDCs
Are DMRs complete do they include all permit parameters?
0
❑
❑
❑
Has the facility submitted its annual compliance report to users and DWQ?
M
❑
❑
❑
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator
❑
❑
M
❑
on each shift?
Is the ORC visitation log available and current?
0
❑
❑
❑
Is the ORC certified at grade equal to or higher than the facility classification?
M
❑
❑
❑
Is the backup operator certified at one grade less or greater than the facility classification?
0
❑
❑
❑
Is a copy of the current NPDES permit available on site?
0
❑
❑
❑
Facility has copy of previous year's Annual Report on file for review?
0
❑
❑
❑
Comment: The records reviewed during the inspection were organized and well maintained.
DMRs,
COCs, Calibration lops and ORC logs were reviewed for the period September 2016
through August 2017
Laboratory
Yes No NA NE
Page# 3
Permit NCO025861 Owner -Facility Lowell WWTP
Inspection Date 11/27/2017 Inspection Type Compliance Evaluation
Laboratory Yes No NA NE
Are field parameters performed by certified personnel or laboratory?
❑
❑ ❑
Are all other parameters(excluding field parameters) performed by a certified lab?
❑
❑ ❑
# Is the facility using a contract lab? M
❑
❑ ❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
❑
❑ ❑
Celsius)?
N
❑
Incubator (Fecal Coliform) set to 44 5 degrees Celsius+/- 0 2 degrees? ❑
❑
0 ❑
Incubator (BOD) set to 20 0 degrees Celsius +/-1 0 degrees? ❑
❑
0 ❑
Comment: On-site field analyses (dissolved oxygen DH temperature, total residual chlorine) are
# Is proper temperature set for sample storage (kept at less than or equal to 6 0 degrees
0
performed under the City's field laboratory certification #5082 PAR Labs. Inc. has been
❑
contracted to perform influent and effluent analyses. Meritech Labs, Inc has also been
Celsius)?
contracted to perform the chronic toxicity analyses. The laboratory instrumentation used for
field analyses appeared to be properly calibrated/verified and documented.
Is sampling performed according to the permit?
M
Influent Sampling
Yes No NA NE
# Is composite sampling flow proportional?
0
❑
❑
❑
Is sample collected above side streams?
M
❑
❑
❑
Is proper volume collected?
N
❑
❑
❑
Is the tubing clean?
0
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6 0 degrees
0
❑
❑
❑
Celsius)?
Is sampling performed according to the permit?
M
❑
❑
❑
Comment. The subiect permit requires composite biochemical oxygen demand
(BOD) and TSS
influent samples Aliquot pulled durinq the inspection was 155 ml.
pulled during
the
Effluent Sampling
Yes No NA NE
Is composite sampling flow proportional?
0
❑
❑
❑
Is sample collected below all treatment units?
M
❑
❑
❑
Is proper volume collected?
M
❑
❑
❑
Is the tubing clean?
N
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
0
❑
❑
❑
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
0
❑
❑
❑
representative)?
Comment- The subject permit requires composite and grab effluent samples Aliquot
pulled during
the
inspection was 170 ml.
Operations & Maintenance
Yes No NA NE
Page# 4
Permit NCO025861 Owner -Facility Lowell wwTP
Inspection Date 11/27/2017 Inspection Type Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑
Does the facility analyze process control parameters, for ex- MLSS, MCRT, Settleable ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: The facility aDDeared to be Droperly operated and well maintained At the time of the
inspection flow meter chart was broken and was in the process of being repaired. At the
time of the inspection there was evidence of stormwater erosion around the influent pump
station.
Bar Screens Yes No NA NE
Type of bar screen
Yes No NA NE
# Is flow meter used for reporting?
❑
0
a Manual
❑
Is flow meter calibrated annually?
0
❑
b.Mechanical
❑
Is the flow meter operational?
N
❑
Are the bars adequately screening debris?
❑
❑
❑
❑
Is the screen free of excessive debris?
❑
❑
❑
❑
Is disposal of screening in compliance?
0
❑
❑
❑
Is the unit in good condition?
0
❑
❑
❑
Comment: The facility is equipped with mechancial and manual bar screens (coarse)
❑
Flow Measurement - Influent
Yes No NA NE
# Is flow meter used for reporting?
❑
0
❑
❑
Is flow meter calibrated annually?
0
❑
❑
❑
Is the flow meter operational?
N
❑
❑
❑
(If units are separated) Does the chart recorder match the flow meter?
0
❑
❑
❑
Comment: Flow meter is calibrated/verified twice per year and was last calibrated/verified on 9/13/2017
E
by Ken Nash Company.
❑
❑
Is SCADA telemetry available and operational?
❑
Pump Station - Influent
Yes No NA NE
Is the pump wet well free of bypass lines or structures?
0
❑
❑
❑
Is the wet well free of excessive grease?
E
❑
❑
❑
Are all pumps present?
0
❑
❑
❑
Are all pumps operable?
N
❑
❑
❑
Are float controls operable?
E
❑
❑
❑
Is SCADA telemetry available and operational?
❑
❑
0
❑
Is audible and visual alarm available and operational?
❑
❑
0
❑
Page# 5
E
Permit NCO025661 Owner - Facility Lowell WWTP
Inspection Date 11/27/2017 Inspection Type Compliance Evaluation
Pump Station - Influent Yes No NA NE
Comment: SCADA is not available_ however, there is an auto dialer to contact the ORC in caste of
power outage At the time of the inspection there was evidence of stormwater erosion,
stormwater control measures (such as norap) should be put alona the side and entrance to
the influent pump station to prevent erosion damage and stormwater flowing into the pump
station wet well.
Aeration Basins
Mode of operation
Type of aeration system
Is the basin free of dead spots?
Are surface aerators and mixers operational?
Are the diffusers operational?
Is the foam the proper color for the treatment processs?
Does the foam cover less than 25% of the basin's surface?
Is the DO level acceptable?
Is the DO level acceptable?(1 0 to 3 0 mg/I)
Yes No NA NE
Diffused
Yes No NA NE
Is the clarifier free of black and odorous wastewater?
E
❑
❑
❑
❑
❑
E
❑
•
❑
❑
❑
•
❑
❑
❑
•
❑
❑
❑
E
❑
❑
❑
■
❑
❑
❑
Comment: The facility uses the contact stabilization treatment process. Sodium Hydroxide is added.
Secondary Clarifier
Yes No NA NE
Is the clarifier free of black and odorous wastewater?
N
❑
❑
❑
Is the site free of excessive buildup of solids in center well of circular clarifier?
0
❑
❑
❑
Are weirs level?
0
❑
❑
❑
Is the site free of weir blockage?
0
❑
❑
❑
Is the site free of evidence of short-circuiting?
0
❑
❑
❑
Is scum removal adequate?
E
❑
❑
❑
Is the site free of excessive floating sludge?
0
❑
❑
❑
Is the drive unit operational?
E
❑
❑
❑
Is the return rate acceptable (low turbulence)?
0
❑
❑
❑
Is the overflow clear of excessive solids/pin floc?
0
❑
❑
❑
Is the sludge blanket level acceptable? (Approximately'/ of the sidewall depth)
E
❑
❑
❑
Comment: The clarfier drive unit arm seemed to not remove all the surface scum.
Disinfection -Gas Yes No NA NE
Are cylinders secured adequately? E ❑ ❑ ❑
Are cylinders protected from direct sunlight? N ❑ ❑ ❑
Page# 6
Permit NCO025861 Owner -Facility LoweIIWWTP
Yes No NA NE
Type of system ?
Gas
❑
Inspection Date 11/27/2017 Inspection Type Compliance Evaluation
❑
Is the feed ratio proportional to chlorine amount (1 to 1)?
E
❑
Disinfection -Gas
Yes No NA NE
Is there adequate reserve supply of disinfectant?
E
❑
❑
❑
Is the level of chlorine residual acceptable?
E
❑
❑
❑
Is the contact chamber free of growth, or sludge buildup?
0
❑
❑
❑
Is there chlorine residual prior to de -chlorination?
N
❑
❑
❑
Does the Stationary Source have more than 2500 lbs of Chlorine (CAS No 7782-50-5)?
❑
0
❑
❑
If yes, then is there a Risk Management Plan on site?
❑
❑
0
❑
If yes, then what is the EPA twelve digit ID Number? (1000- - )
If yes, then when was the RMP last updated?
Comment: About 900 lbs. of chlorine stored on site.
De -chlorination
Yes No NA NE
Type of system ?
Gas
❑
❑
❑
Is the feed ratio proportional to chlorine amount (1 to 1)?
E
❑
❑
❑
Is storage appropriate for cylinders?
0
❑
❑
❑
# Is de -chlorination substance stored away from chlorine containers?
❑
0
❑
❑
Are the tablets the proper size and type?
❑
❑
0
❑
Comment: The chlorination and dechlorination cylinders are stored together Inside a building equipped
with ventilation and a leakage detection system.
Are tablet de -chlorinators operational? ❑ ❑ ❑
Number of tubes In use?
Comment:
Flow Measurement - Effluent
Yes No NA NE
# Is flow meter used for reporting?
0
❑
❑
❑
Is flow meter calibrated annually?
E
❑
❑
❑
Is the flow meter operational?
N
❑
❑
❑
(If units are separated) Does the chart recorder match the flow meter?
❑
N
❑
❑
Comment: Flowmeter is calibrated/verified_ twice per year and was last calibrated/verified on 9/13/2017
by Ken Nash Company. At the time of the inspection flow meter chart recorder was broken
and was in the process of being repaired.
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑
Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑
Page# 7
Permit NC0025861 Owner -Facility LoweIIWWTP
Inspection Date 11/27/2017 Inspection Type Compliance Evaluation
Effluent Pipe Yes No NA NE
,If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑
Comment. The effluent appeared clear with no negative impact to the stream
Aerobic Digester
Yes No NA NE
Is the capacity adequate?
0
❑
❑
❑
Is the mixing adequate?
M
❑
❑
❑
Is the site free of excessive foaming In the tank?
M
❑
❑
❑
# Is the odor acceptable?
0
❑
❑
❑
# Is tankage available for properly waste sludge?
0
❑
❑
❑
Comment.
Dryinq Beds
Yes No NA NE
Is there adequate drying bed space?
M
❑
❑
❑
Is the sludge distribution on drying beds appropriate?
M
❑
❑
❑
Are the drying beds free of vegetation?
M
❑
❑
❑
# Is the site free of dry sludge remaining in beds?
M
❑
❑
❑
Is the site free of stockpiled sludge?
N
❑
❑
❑
Is the filtrate from sludge drying beds returned to the font of the plant?
M
❑
❑
❑
# Is the sludge disposed of through county landfill?
N
❑
❑
❑
# Is the sludge land applied?
M
❑
❑
❑
(Vacuum filters) Is polymer mixing adequate?
0
❑
❑
❑
Comment: Dewatered sludge Is transported to landfill
Standby Power
Yes No NA NE
Is automatically activated standby power available?
M
❑
❑
❑
Is the generator tested by interrupting primary power source?
M
❑
❑
❑
Is the generator tested under load?
0
❑
❑
❑
Was generator tested & operational during the Inspection?
❑
❑
❑
M
Do the generator(s) have adequate capacity to operate the entire wastewater site?
M
❑
❑
❑
Is there an emergency agreement with a fuel vendor for extended run on back-up power?
0
❑
❑
❑
Is the generator fuel level monitored?
M
❑
❑
❑
Comment. The standby generator Is tested (automatically) once per week. The City/Permittee
contracts a company to service the generator twice per year.
Page# 8
,a
Water Resources
Environmental Quality
November 27, 2017
Mr. Robert Patterson, Water Resources Director
City of Burlington
PO Box 1358
Burlington, NC 27216-1358
Subject: Compliance Evaluation Inspection Report
NPDES Permit NCO023868
East Burlington WWTP, Alamance County
Dear Mr. Patterson:
ROY COOPER
Governor
MICHAEL S. REGAN
Secretary
LINDA CULPEPPER
Interim Director
RECEIVED/DENR/DWR
DEC 0 5 2017
Water Resources
Permitting Section
On November 21, 2017, Paul DiMatteo of the Division of Water Resources ("Division"), Winston-Salem
Regional Office conducted a Compliance Evaluation Inspection of the above referenced wastewater treatment
system. The presence and cooperation of Mr. Darrin Allred was greatly appreciated. This type of inspection
consists of two basic parts: an on-site inspection of the facility and a review of facility files and self-monitoring
data. Observations from each area of the inspection are summarized below.
Site Review
1. Permit
The current permit became effective on July 1, 2014 and expires on June 30, 2019. A copy of the
current permit was available for review. Permitted components include a 4 million gallon aerated
equalization basin, primary and secondary clarifiers, biological phosphorus reduction, sand
filtration, and gas chlorination.
2. Facility Site Review
The facility was as described in the permit. At the time of inspection, one secondary clarifier was
down for routine maintenance. It was noted during the previous inspection that the plant planned
to replace the gas chlorine disinfection system with liquid chlorine; however, Mr. Allred said that
the details had not yet been finalized. The backup power generator is tested under load every
month. An Authorization to Construct was recently issued for a dewatering press and related
systems. Mr. Allred said that the installation was progressing well.
--` 7',—Nathing Compares_-_.
State of North Carolina I Environmental Quality
450 W Hanes Mill Road, Suite 300, Winston-Salem, North Carolina 27105
Phone. 336-776-98001 FAX 336-776-9797
3. Operation and Maintenance
Darrin Allred is the current Operator in Responsible Charge, and Eric Davis and Kenneth Timson are
backup ORCs. All operators are properly designated and hold the correct credentials. The operators
use the Hach Water Information Management Systems (WIMS) database to track trends in the
treatment process and integrate reporting and documentation, and the Hach JOB Cal system to
track all preventative and repair work at the plant. Mr. Allred also keeps a paper notebook
documenting his daily plant visitations.
4. Flow Measurement
Effluent flow is measured with an ultrasonic secondary device set above a 2 foot Parshall flume.
The calibration is checked quarterly by Instrument Specialists, Inc.
5. Effluent/Receiving Waters
The effluent is discharged to the Haw River in the Cape Fear River Basin. Effluent appeared clear
with no visible solids. In -stream monitoring requirements have been waived as long as the City of
Burlington remains a member of the Upper Cape Fear River Basin Association.
Documentation Review
6. Records/Reports
Discharge Monitoring Reports (DMRs) and lab data are maintained according to the permit. DMRs
include all permit parameters. Copies of DMRs, operator visitation logs, daily operation sheets,
maintenance reports, lab reports and Chain -of -Custody forms were available for review during the
inspection.
7. Self -Monitoring Program
A review of DMRs from September, 2016 through September, 2017 showed no violations, and a
comparison of submitted DMR data with bench records showed no errors or concerns.
8. Laboratory
All parameters are analyzed by the City of Burlington Wastewater Treatment Plant Laboratory
under certification #188, except for headworks, toxicity and the effluent pollutant scan, which are
analyzed by Meritech under certification #165. When a separate lab analyzes headworks samples,
they also analyze all other samples collected that day. Operators of the plant analyze field
parameters under the City of Burlington WWTP Lab's certification. Copies of all laboratory
documentation are kept at the Burlington WWTP Lab.
Effluent composite sampler is flow proportional. During the inspection, the thermometer inside the
sampler read 0.5°C at the effluent and 2.5'C at the influent. Sampling and field parameter
measurement procedures appeared acceptable.
9. Sludge Handling Disposal
Lime stabilized residuals are land applied according to Division of Water Resources Permit
WQ0000520. A portion of residuals stabilized by the Zimpro process are disposed of via transport
to the landfill. Hauling records for each type of disposal were available at the time of inspection.
If you should have any questions, please do not hesitate to contact Paul DiMatteo at (336) 776-9691 or
our office at (336) 776-9800.
Sincerely,
�6"/Sherri V. Knight, P.E., Regional Supervisor
Water Quality Regional Operations Section
Winston-Salem Regional Office
Division of Water Resources, NCDEQ
Enclosures —Inspection Report and Summary
CC: Darrin Allred, by email
WQS Winston-Salem Regional Office - Enforcement File
NPDES Compliance/Enforcement Unit - Enforcement File
Central Files
United States Environmental Protection Agency
Form Approved
EPA Washington, D C 20460
OMB No 2040-0057
Water Compliance Inspection Report
Approval expires B-31-98
Section A National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 E j 2 15 1 3 I NCO023868 111 12 17/11/21 17 181.-1 191 c I 201 I
211 1 1 1 I I I I I I 11 I I I I I I I I I I I I I I I I I I I I I I I 11 I I I I jJ6
-Reserved —
Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA ---Reserved--
671 72 Lti 731 I 74 75 1 1 1 1 1 80
67 70 J 71 itJ
Section B Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES permit Number)
12 30PM 17/11/21
14/07/01
Eastside WWTP
Exit Time/Date
Permit Expiration Date
225 Stone Quarry Rd
Burlington NC 27216
03 45PM 17/11/21
19/06130
Name(s) of Onsite Representative(s)/Tifies(s)/Phone and Fax Number(s)
Other Facility Data
Darnn Lee Allred/ORC/336-558-8520/
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Robert C Patterson,PO Box 1358 Burlington NC
No
272161358//336-222-5130/3365706175
Section C Areas Evaluated During Inspection (Check only those areas evaluated)
Permit E Flow Measurement Operations & Maintenance Records/Reports
Self -Monitoring Program E Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters
Laboratory
Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
PauliMatteo WSRO WQ//336-776-9691/
X171017
Signature of anagement Q A ReviewerAgency/Office/Phone and Fax Numbers Date
� ,'
67 12117
1/
G `
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete
Page#
NPDES yr/mo/day Inspection Type (Cont
31 NCO023868 111 121 17/11/21 1 17 18 ICI
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Site Review
1. Permit
The current permit became effective on July 1, 2014 and expires on June 30, 2019. A copy of the
current permit was available for review. Permitted components include a 4 million gallon aerated
equalization basin, primary and secondary clarifiers, biological phosphorus reduction, sand filtration,
and gas chlorination.
2. Facility Site Review
The facility was as described in the permit. At the time of inspection, one secondary clarifier was down
for routine maintenance It was noted during the previous inspection that the plant planned to replace
the gas chlorine disinfection system with liquid chlorine; however, Mr Allred said that the details had
not yet been finalized. The backup power generator is tested under load every month. An Authorization
to Construct was recently issued for a dewatering press and related systems. Mr. Allred said that the
Installation was progressing well.
3. Operation and Maintenance
Daren Allred is the current Operator in Responsible Charge, and Eric Davis and Kenneth Timson are
backup ORCs. All operators are properly designated and hold the correct credentials. The operators
use the Hach Water Information Management Systems (WIMS) database to track trends in the
treatment process and integrate reporting and documentation, and the Hach JOB Cal system to track
all preventative and repair work at the plant. Mr. Allred also keeps a paper notebook documenting his
daily plant visitations
4. Flow Measurement
Effluent flow is measured with an ultrasonic secondary device set above a 2 foot Parshall flume. The
calibration is checked quarterly by Instrument Specialists, Inc.
5 Effluent/Receiving Waters
The effluent is discharged to the Haw River in the Cape Fear River Basin. Effluent appeared clear with
no visible solids. In -stream monitoring requirements have been waived as long as the City of Burlington
remains a member of the Upper Cape Fear River Basin Association.
Documentation Review
6 Records/Reports
Discharge Monitoring Reports (DMRs) and lab data are maintained according to the permit. DMRs
include all permit parameters. Copies of DMRs, operator visitation logs, daily operation sheets,
maintenance reports, lab reports and Chain -of -Custody forms were available for review during the
inspection.
7. Self -Monitoring Program
A review of DMRs from September, 2016 through September, 2017 showed no violations, and a
comparison of submitted DMR data with bench records showed no errors or concerns.
8. Laboratory
All parameters are analyzed by the City of Burlington Wastewater Treatment Plant Laboratory under
certification #188, except for headworks, toxicity and the effluent pollutant scan, which are analyzed by
Meritech under certification #165. When a separate lab analyzes headworks samples, they also
analyze all other samples collected that day Operators of the plant analyze field parameters under the
City of Burlington WWTP Lab's certification. Copies of all laboratory documentation are kept at the
Burlington WWTP Lab.
Effluent composite sampler is flow proportional. During the inspection, the thermometer inside the
sampler read 0 5°C at the effluent and 2.5°C at the influent. Sampling and field parameter
measurement procedures appeared acceptable.
9 Sludge Handling Disposal
Lime stabilized residuals are land applied according to Division of Water Resources Permit
WQ0000520 A portion of residuals stabilized by the Zimpro process are disposed of via transport to
Page#
Permit NC0023868
Owner - Facility: Eastside WWTP
Inspection Date. 11/21/2017 InspectionType, Compliance Evaluation
the landfill Hauling records for each type of disposal were available at the time of inspection
Page#
Permit, NCO023868 Owner - Facility: Eastside WWTP
Inspection Date: 11/21/2017 Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑
Does the facility analyze process control parameters, for ex MLSS, MCRT, Settleable 0 ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Permit
Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
❑
❑
M
❑
application?
❑
❑
❑
❑
Is the facility as described in the permit?
0
❑
❑
❑
# Are there any special conditions for the permit?
❑
0
❑
❑
Is access to the plant site restricted to the general public?
M
❑
❑
❑
Is the inspector granted access to all areas for inspection?
M
❑
❑
❑
Comment:
Record Keeping
Yes No NA NE
Are records kept and maintained as required by the permit?
❑
❑
❑
❑
Is all required information readily available, complete and current?
❑
❑
❑
❑
Are all records maintained for 3 years (lab. reg. required 5 years)?
❑
❑
❑
❑
Are analytical results consistent with data reported on DMRs?
❑
❑
❑
❑
Is the chain -of -custody complete?
M
❑
❑
❑
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported CDCs
Are DMRs complete- do they include all permit parameters?
❑
❑
❑
Has the facility submitted its annual compliance report to users and DWQ?
❑
❑
❑
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator
❑
❑
❑
on each shift?
Is the ORC visitation log available and current?
0
❑
❑
❑
Is the ORC certified at grade equal to or higher than the facility classification?
0
❑
❑
❑
Is the backup operator certified at one grade less or greater than the facility classification?
M
❑
❑
❑
Is a copy of the current NPDES permit available on site?
0
❑
❑
❑
Page# 4
Permit NC0023868 Owner - Facility. Eastside WWTP
Inspection Date: 11/21/2017 Inspection Type- Compliance Evaluation
Record Keeping Yes No NA NE
Facility has copy of previous year's Annual Report on file for review? 0 ❑ ❑ ❑
Comment
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑
Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ ❑
If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ ❑
Comment: Step aeration after dechlorination, before discharge.
Flow Measurement - Effluent
Yes No NA NE
# Is flow meter used for reporting?
0
❑
❑
❑
Is flow meter calibrated annually?
0
❑
❑
❑
Is the flow meter operational?
❑
❑
❑
❑
(If units are separated) Does the chart recorder match the flow meter?
❑
❑
M
❑
Comment. 2 ft Parshall flume w/ doppler device. Checked every 3 months by ISI.
Chemical Feed
Yes No NA NE
Is containment adequate?
M
❑
❑
❑
Is storage adequate?
0
❑
❑
❑
Are backup pumps available?
❑
❑
❑
0
Is the site free of excessive leaking?
M
❑
❑
❑
Comment
Aerobic Digester
Yes No NA NE
Is the capacity adequate?
0
❑
❑
❑
Is the mixing adequate?
M
❑
❑
❑
Is the site free of excessive foaming in the tank?
0
❑
❑
❑
# Is the odor acceptable?
M
❑
❑
❑
# Is tankage available for properly waste sludge?
M
❑
❑
❑
Comment:
Pump Station - Influent Yes No NA NE
Is the pump wet well free of bypass lines or structures? 0 ❑ ❑ ❑
Page# 5
Permit: NC0023868
Inspection Date: 11/21/2017
Pump Station - Influent
Is the wet well free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Is SCADA telemetry available and operational?
Is audible and visual alarm available and operational?
Comment -
Bar Screens
Type of bar screen
a.Manual
b Mechanical
Are the bars adequately screening debris?
Is the screen free of excessive debris?
Is disposal of screening in compliance?
Is the unit in good condition?
Comment. Manual bar screen available as backup
Grit Removal
Type of grit removal
a.Manual
b Mechanical
Is the grit free of excessive organic matter?
Is the grit free of excessive odor?
# Is disposal of grit in compliance?
Comment
Owner - Facility. Eastside wwTP
Inspection Type. Compliance Evaluation
Equalization Basins
Is the basin aerated?
Is the basin free of bypass lines or structures to the natural environment?
Is the basin free of excessive grease?
Are all pumps present?
Are all pumps operable?
Yes No NA NE
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ❑ ■
■ ❑ ❑ ❑
❑ ❑ ❑ ■
Yes No NA NE
El
■
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
Yes No NA NE
■
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
Yes No NA NE
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
Page# 6
Permit- NCO023868
Owner -Facility: Eastside WWTP
Is the clarifier free of black and odorous wastewater?
M
❑
Inspection Date- 11/21/2017
Inspection Type Compliance Evaluation
Is the site free of excessive buildup of solids in center well of circular clarifier?
M
❑
Equalization Basins
Yes No NA NE
Are float controls operable?
0
❑
❑
❑
Are audible and visual alarms operable?
❑
❑
❑
0
# Is basin size/volume adequate?
0
❑
❑
❑
Comment:
Primary Clarifier
Yes No NA NE
Is the clarifier free of black and odorous wastewater?
M
❑
❑
❑
Is the site free of excessive buildup of solids in center well of circular clarifier?
M
❑
❑
❑
Are weirs level?
N
❑
❑
❑
Is the site free of weir blockage?
0
❑
❑
❑
Is the site free of evidence of short-circuiting?
N
❑
❑
❑
Is scum removal adequate?
0
❑
❑
❑
Is the site free of excessive floating sludge?
0
❑
❑
❑
Is the drive unit operational?
0
❑
❑
❑
Is the sludge blanket level acceptable?
❑
❑
❑
0
Is the sludge blanket level acceptable? (Approximately 1/4 of the sidewall depth)
❑
❑
❑
M
Comment:
Secondary Clarifier
Yes No NA NE
Is the clarifier free of black and odorous wastewater?
0
❑
❑
❑
Is the site free of excessive buildup of solids in center well of circular clarifier?
M
❑
❑
❑
Are weirs level?
❑
❑
❑
Is the site free of weir blockage?
❑
❑
❑
Is the site free of evidence of short-circuiting?
❑
❑
❑
Is scum removal adequate?
❑
❑
❑
Is the site free of excessive floating sludge?
0
❑
❑
❑
Is the drive unit operational?
❑
❑
❑
Is the return rate acceptable (low turbulence)?
❑
❑
❑
Is the overflow clear of excessive solids/pin floc?
❑
❑
❑
Is the sludge blanket level acceptable? (Approximately % of the sidewall depth)
❑
❑
❑
Comment Per ORC try to keep sludge blanket to 0 5 ft or less for better nutrient removal.
Aeration Basins Yes No NA NE
Page# 7
Permit NCO023868
Inspection Date• 11/21/2017
Aeration Basins
Mode of operation
Type of aeration system
Is the basin free of dead spots?
Are surface aerators and mixers operational?
Are the diffusers operational?
Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin's surface?
Is the DO level acceptable?
Is the DO level acceptable?(1.0 to 3.0 mg/1)
Owner - Facility Eastside WWTP
Inspection Type: Compliance Evaluation
Comment- At effluent end, process control DO probe read 1.73 mg/L
Nutrient Removal
# Is total nitrogen removal required?
# Is total phosphorous removal required?
Type
# Is chemical feed required to sustain process?
Is nutrient removal process operating properly?
Comment
Filtration (Hi-gh Rate Tertiary)
Type of operation -
Is the filter media present?
Is the filter surface free of clogging?
Is the filter free of growth?
Is the air scour operational?
Is the scouring acceptable?
Is the clear well free of excessive solids and filter media'
Comment: Not evaluated during Inspection due to time constraints.
Disinfection -Gas
Are cylinders secured adequately?
Are cylinders protected from direct sunlight?
Is there adequate reserve supply of disinfectant?
Yes No NA NE
Ext. Air
Diffused
■ ❑ ❑ ❑
❑ ❑ ■ ❑
N ❑ 1:111
■ ❑ 1:111
• ❑ ❑ ❑
• ❑ 1:11:1
• ❑ ❑ ❑
Yes No NA NE
[Is ❑❑
■ ❑ ❑ ❑
Biological
Yes No NA NE
Down flow
■ ❑ ❑ ❑
❑ ❑ ❑ ■
❑ ❑ ❑ N
❑ ❑ ❑ ■
❑ ❑ ❑ N
❑ ❑ ❑ ■
Yes No NA NE
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
Page# 8
6 #a6ed
❑ ❑ ❑ M Lleuoijejedo sdwnd eiV
❑ ❑ ❑ ■ /_aoeld w sdwnd eiV
3N VN ON saA SVAkS"-s wnd
lgluow palsal Iuewwoo
❑
❑
❑
0
IpaJo}luow lana) lon; jo;ejeua6 eq; sl
❑
❑
❑
0
Z jemod do-Noeq uo uni papua}xa Jo; Jopuan lanj a gjim juawaoibe loue6jewe ue eiagl sl
❑
❑
❑
0
4,91is jalennalseM an}ue aqj ejejedo of lgtaedeo ejenbape aneq (s)Jo}eJau96 aq; oQ
❑
❑
❑
e,uoi}oadsul eq; 6uunp leuogejedo +g palsal jolejaua6 seM
❑
❑
❑
0
epeol japun pa}sa; jolejeua6 eq} sl
❑
❑
❑
M
Laoinos jaMod lvewud 6ul;dnijejul Aq pa;sa} jolejaua6 eq; sl
❑
El
11e,9lgeliene
jamod Agpue}s pa;enl}ae Alleol}ewo}ne sl
3N VN ON saA
JaNwd Aqpu9FS
;uewwoo
e,asn ui segnj jo jegwnN
❑ 0 ❑ ❑ Zleuogejedo sio}euuolgo-ap jelge; eiV
❑ ❑ ❑ 0 ead/4 pue ezis jadoid eqj slalge} eq; eiV
quawwoo
❑
❑
❑
m
LSAauleJuoa auuolga waJ A13ME paJo;s e3ue;sgns uoi}euuolgo-ap sl #
❑
❑
❑
0
esJ8puljA3 Jo,} eleudadde 96ejols sl
❑
El
11e,(L
o; L) }unowe awJolga of leumpodoid oijej peal aql sl
❑
❑
SEE)
a wa}sAs;o ads _L
3N VN ON saA
UOI;BUIJO143-a(]
•alnpegos a uo pauealo pue umop unnelp sl .lagwego }oe}uoo euuolgo eq} Jo fed }uawwOO
e,pa}epdn Isel dMI aq} seM uagM uaq) 'sa/(;I
3N
(-- -000 L) cjagwnN QI 1161p anlann} yd3 aq} si 18gm uaq; 'say(1I
❑
❑
❑
M
01ls uo ueld luaw96eueW WI l a ajaq; si uagl 'saA 11
❑
❑
❑
1,(9-09-ULL 'oN SVO) euuolgo do sql 009Z ueq; avow aneq aomoS /ueuoile;S eq; saoa
❑
❑
❑
e,uoljeuuolgo-9p o; joljd lenplsaj auuolgo eiagj sl
❑
❑
❑
M
4dnplinq e6pnls .lo 'q;Ma6 jo oeil jegwego joe}uoo eq; sl
M
❑
❑
❑
4alge;d93oe lenpisei auuolga 10 lanai eq; sI
3N VN ON sGA
sed-UOI;Oa;UISIQ
uogenlen3 aouegdwoo adlll uol;oedsul LLOZ/6Z/l l :a;ea uol;aadsul
d1MM apis;sea '��Pae3 - Jeumo 899£ZOODN 31wJad
Permit: NCO023868 Owner -Facility. EastsideWWTP
Inspection Date. 11/21/2017 Inspection Type- Compliance Evaluation
Pumps -RAS -WAS Yes No NA NE
Are there adequate spare parts and supplies on site? 0 ❑ ❑ ❑
Comment
Laboratory
E
Yes No NA NE
Are field parameters performed by certified personnel or laboratory?
N
❑
❑
❑
Are all other parameters(excluding field parameters) performed by a certified lab?
0
❑
❑
❑
# Is the facility using a contract lab?
❑
M
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
0
❑
❑
❑
Celsius)?
Is sample collected above side streams?
0
❑
❑
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
M
❑
❑
❑
Incubator (BOD) set to 20 0 degrees Celsius +/- 10 degrees?
0
❑
❑
❑
Comment Primary laboratory Inspected 10125/2017. BOD Incubator 19 5 C: Fecal incubator 44.5 C
(According to their thermometers). Field parameters are measured on site under Burlington
Yes No NA NE
Is composite sampling flow proportional?
WWTP's certification. On-site calibration records appeared acceptable. Thermometers
❑
❑
❑
were last calibrated in October 2016 - Mr Allred said that they were in the
process of having
❑
❑
the main laboratory conduct the calibration.
Is proper volume collected?
0
❑
❑
Influent Sampling
Yes No NA NE
# Is composite sampling flow proportional?
M
❑
❑
❑
Is sample collected above side streams?
0
❑
❑
❑
Is proper volume collected?
❑
❑
❑
Is the tubing clean?
❑
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6 0 degrees
❑
❑
❑
Celsius)?
Is sampling performed according to the permit?
M
❑
❑
❑
Comment: Refrigerator 2.5 C.
Effluent Sampling
Yes No NA NE
Is composite sampling flow proportional?
❑
❑
❑
Is sample collected below all treatment units?
❑
❑
❑
Is proper volume collected?
0
❑
❑
❑
Is the tubing clean?
N
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
0
❑
❑
❑
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
M
❑
❑
❑
representative)?
Page# 10
Permit NCO023868
Inspection Date 11/2112017
Effluent Sampling
Comment. Refrigerator 0.5 C
Owner • Facility Eastside WWTP
Inspection Type. Compliance Evaluation
Yes No NA NE
Page# 11