HomeMy WebLinkAboutNC0029882_Authorization to Construct_20171129HE COUNTRY 11 29 2017 North Carolina DEQ - Division of Water Resources ATTN: Mr. Ron Berry 512 N. Salisbury Street, 9th Floor Raleigh, NC 27604 RE: Chlorine Contact Chamber Replacement Bnarwood Subdivision WWTP NPDES Permit#: NCO029882 Dear Mr. Berry, Please find enclosed a Authorization to Construct request for the Briarwood Subdivision WWTP. The plant is privately owned, serves a small subdivision, and is located in Buncombe County. This project is for the replacement of the existing chlorine contact chamber at the WWTP and would be considered a facility modification. The timeline for this project is to install the tank as soon as possible. The operator for the WWTP is Ms. Juanita James. Currently, there are 15 single family homes connected to the WWTP and there are no plans to expand or add any additional homes to the WWTP. WWTP Components The WWTP at Windy Gap consists of the following elements 1. Manual Bar Screen 2. Reactor Basin 3. Clarifier 4. Chlorine Contact Chamber 5. Dechlonnation Manhole 6. Associated piping and blowers for aeration Existing Chlorine Contact Chamber The existing chlorine contact chamber is original to the plan and is no longer structurally sound. The walls and baffles of the chamber were constructed with masonry block and thejoints are cracking. The exterior walls are no longer plumb and are bowing inwards on the structure. Chlorine Contact Chamber Replacement The proposed 356 GAL chlorine contact chamber will provide adequate a minimum of 15 minutes of contact time at the maximum peak flow for the WWTP. A local concrete precast company will be use to cast the chamber and baffle walls. The proposed chamber will connect to the existing influent and effluent lines at the WWTP. HIGH COUNTRY ENGINEERING, PC TELEPHONE 828 231 9380 FAX. 828 348 5040 41 Clayton St Ste 300, Asheville, NC 28801 Chlorine Contact Chamber Replacement 11292017 Construction Sequence The construction sequence is as follows 1 Block flow from entering existing chlorine contact chamber 2 Pump and dispose of wastewater in existing chlorine contact chamber 3 Pump and dispose of wastewater in existing clarifier 4 Demolish old chlorine contact chamber 5 Install new chlorine contact chamber 6 Test and place new chlorine contact chamber 7 Return flow to normal operation Mr David Burnette is the owner of the WWT:l and is also a licensed utility contractor He will be performing the work described above, except the hauling and pumping with will require a licensed septic hauler A 3,500 gallon septic tank pumping truck will be used and based on his experience, the plant will not discharge for roughly 48 hours Engineering Calculations Attached to this letter are the calculations for the chlorine contact time, the buoyancy calculations, and the bearing capacity of the new tank Soil borings were not completed for this project and therefore the depth of the watertable is not known Based on my own observations, I do not anticipate the water table being less than 3' deep No additional permits are needed to complete this work The disturbance is less than 1 acre and therefore an Erosion Control Permit is not required by the ordinance in Buncombe County Attachments for Review The following items are attached for review • Application for Authorization to Construct Permit (Form ATC -12-14) c NPDES Permit • Engineering Plans • Engineering Calculations (Two pages attached to this cover letter) • Technical Specifications • 1 CD with a digital copy of all of the above items If there are any questions related to this pro ect, please do not hesitate to contact me Sincerely, 40 Michael R Goforth, PE High Country Engineering, PC HIGH COUNTRY ENGINEERING, PC TELEPHONE 828 231 9380 FAX 828 348 5040 41 Clayton St Ste 300, Asheville, NC 28801 o �?-q,? 1?zA State of North Carolina {�Y NC o02W Department of Environmental Quality Division of Water Resources Water Resources ENVIRONMENTAL QUALITY APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14) SECTION 1: INSTRUCTIONS AND INFORMATION A. The Division of Water Resources will accept this application package for review only if all of the items are provided and the application is complete. Failure to submit all of the required items will result in the application package being returned as incomplete per 15A NCAC 02T .0105(b) B. Plans and specifications must be prepared in accordance with 15 NCAC 02H. 0100. 15A NCAC 02T, North Carolina General Statute 133-3. North Carolina General Statute 143-215 1. and Division of Water Resources Minimum Design Criteria for NPDES Wastewater Treatment Facilities. C. The plans and specifications submitted must represent a completed final design that is ready to advertise for bid D. Any content changes made to this Form ATC -12-14 shall result in the application package being returned E. The Applicant shall submit ONE ORIGINAL and ONE DIGITAL COPY (CD) of the application, all supporting documentation and attachments. All information must be submitted bound or in a 3 -ring binder, with a Section tab for each Section, except the Engineering Plans. F. Check the boxes below to indicate that the information is provided and the requirements are met. G. If attachments are necessary for clarity or due to space limitations, such attachments are considered part of the application package and must be numbered to correspond to the item referenced. H. For any project that requires review under the State Environmental Policy Act (SEPA), an Authorization to Construct cannot be issued prior to the completion of a State Clearinghouse advertisement period for a FONSI, EIS, etc unless the project qualifies for a Determination of Minor Construction Activity I. For more information, visit the Division of Water Resources web site at. http //portal ncdenr.org/web/wq/swp/ps/npdes. J. In addition to this Authorization to Construct, the Applicant should be aware that other permits may be required from other Sections of the Division of Water Resources (for example: reclaimed water facilities permits; Class A or B biosolids residuals permit). SECTION 2: APPLICANT INFORMATION AND PROJECT DESCRIPTION A. APPLICANT Applicant's name Briarwood Subdivision WWTP Signature authority's name per 15A NCAC 02T 0106(b) David Burnette Signature authority's title Owner Complete mailing address 41 Dix Creek One Road Telephone number 828-275-3563 Email address davideburnette@yahoo.com B. PROFESSIONAL ENGINEER Professional Engineer's name Michael R Goforth Professional Engineer's title Project Manager North Carolina Professional Engineer's License No 33862 Firm name High County Engineering, PC Firm License number C-3347 Complete mailing address 41 Clayton Street, Suite 300, Asheville NC 28801 Application for Authorization to Construct Permit (FORM ATC -12-14) Page 1 Water Resources ENVIRONMENTAL QUALITY State of North Carolina Department of Environmental Quality Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14) Telephone number 828-230-4511 Email address mgoforth@hcepc.net C. NPDES PERMIT NPDES Permit number NCO029882 Current Permitted flow (MGD) — include permit flow phases if applicable 0.0075 D. PROJECT DESCRIPTION Provide a brief description of the project Continue to operate existing wastewater treatment plan Replace existing CCC with new 325 gal precast concrete CCC. SECTION 3: APPLICATION ITEMS REQUIRED FOR SUBMITTAL FOR ALL PROJECTS A. Cover Letter ® The letter must include a request for the Authorization to Construct, the facility NPDES Number; a brief project description that indicates whether the project is a new facility, facility modification, treatment process modification, or facility expansion; the construction timeline; and a list of all items and attachments included in the application package. ® If any of the requirements of 15 NCAC 02-1. 0100. 15A NCAC 02T .0504(c)(1) 15 NCAC 02B. 0400, 15A NCAC 02B. 0500. North Carolina General Statute 143-215.1 and Division of Water Resources Minimum Design Criteria for NPDES Wastewater Treatment Facilities are not met by the proposed design, the letter must include an itemized list of the requirements that are not met. B. NPDES Permit ® Submit Part I of the Final NPDES permit for this facility, that includes Part A (Effluent Limitations and Monitoring Requirements) for the monthly average flour limit that corresponds to the work that is requested for this project. C. Special Order by Consent ❑ If the facility is subject to any Special Orders by Consent (SOC), submit the applicable SOC. ® Not Applicable. D. Finding of No Significant Impact or Record of Decision ❑ Submit a copy of the Finding of No Significant Impactor Record of Decision for this project. ❑ Provide a brief description of any of the mitigating factors or activities included in the approved Environmental Document that impact any aspect of design of this project, if not specified in the Finding of No Significant Impact or Record of Decision. ® Not Applicable. E. Engineering Plans ® Per 15A NCAC 02T .0504(c)(1), submit one set of detailed plans that have been signed, sealed and dated by a North Carolina Licensed Professional Engineer. Application for Authorization to Construct Permit (FORM ATC -12-14) Page 2 State of North Carolina Department of Environmental Quality Division of Water Resources Water Resources ENVIRONMENTAL QUALITY APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14) ® Per 21 NCAC 56 .1103(a)(6), the name, address and License number of the Licensee's firm shall be included on each sheet of the engineering drawings. ID Plans must be labeled as follows: FINAL DRAWING — FOR REVIEW PURPOSES ONLY— NOT RELEASED FOR CONSTRUCTION. ® 15A NCAC 02H .0124 requires multiple (dual at a minimum) components such as pumps, chemical feed systems, aeration equipment and disinfection equipment. Is this requirement met by the design? ❑ Yes or ® No. If no, provide an explanation: No changes to any of these items at this time. Plans shall include: ® Plans for all applicable disciplines needed for bidding and construction of the proposed project (check as appropriate): ® Civil ❑ Not Applicable ❑ Process Mechanical ® Not Applicable ❑ Structural ® Not Applicable ❑ Electrical ® Not Applicable ❑ Instrumentation/Controls ® Not Applicable ❑ Architectural ® Not Applicable ❑ Building Mechanical ® Not Applicable ❑ Building Plumbing ® Not Applicable ® Plan and profile views and associated details of all modified treatment units including piping, valves, and equipment (pumps, blowers, mixers, diffusers, etc.) ❑ Are any modifications proposed that impact the hydraulic profile of the treatment facility? ❑ Yes or ® No If yes, provide a hydraulic profile drawing on one sheet that includes all impacted upstream and downstream units. The profile shall include the top of wall elevations of each impacted treatment unit and the water surface elevations within each impacted treatment unit for two flow conditions: (1) the NPDES permitted flow with all trains in service and (2) the peak hourly flow with one treatment train removed from service ❑ Are any modifications proposed that impact the process flow diagram or process flow schematic of the treatment facility? ❑ Yes or ® No. If yes, provide the process flow diagram or process flow schematic showing all modified flow paths including aeration, recycle/return, wasting, and chemical feed, with the location of all monitoring and control instruments noted. F. ® Engineering Specifications ® Per 15A NCAC 02T .0504(c)(2), submit one set of specifications that have been signed, sealed and dated by a North Carolina Licensed Professional Engineer. ® Specifications must be labeled as follows. FINAL SPECIFICATIONS — FOR REVIEW PURPOSES ONLY — NOT RELEASED FOR CONSTRUCTION. Specifications shall include: ® Specifications for all applicable disciplines needed for bidding and construction of the proposed project (check as appropriate): ® Civil ❑ Not Applicable ❑ Process Mechanical ® Not Applicable ❑ Structural ® Not Applicable ❑ Electrical ® Not Applicable Application for Authorization to Construct Permit (FORM ATC -12-14) Page 3 State of North Carolina Department of Environmental Quality C. - Division of Water Resources Water Resources ENVIRONMENTAL OLIALITY APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14) ❑ Instrumentation/Controls ® Not Applicable ❑ Architectural ® Not Applicable ❑ Building Mechanical ® Not Applicable ❑ Building Plumbing ® Not .Applicable ® Detailed specifications for all treatment units and processes including piping, valves, equipment (pumps, blowers, mixers, diffusers, etc.), and instrumentation. ID Means of ensuring quality and integrity of the finished product including leakage testing requirements for structures and pipelines, and performance testing requirements for equipment. ❑ Bid Form for publically bid projects. N/A G. Construction Sequence Plan ® Construction Sequence Plan such that cons ruction activities will not result in overflows or bypasses to waters of the State. The Plan must not imply that the Contrac_or is responsible for operation of treatment facilities List the location of the Construction Sequence Plan as in the Engineering Plans or in the Engineering Specifications or in both: H. Engineering Calculations ® Per 15A NCAC 02T 0504(c)(3) submit one set of engineering calculations that have been signed, sealed and dated by a North Carolina Licensed Professional Eneireer; the seal, signature and date shall be placed on the cover sheet of the calculations. For new or expanding facilities and for treatment process modifications that are included in Section 4.C, the calculations shall include at a minimum: ❑ Demonstration of how peak hour design flow was determined with a justification of the selected peaking factor ❑ Influent pollutant loading demonstrating how the design influent characteristics in Section 4.6 2 of this form were determined. ❑ Pollutant loading for each treatment unit demonstrating how the design effluent concentrations in Section 4 B.2 of this form were determined ® Hydraulic loading for each treatment unit. ❑ Sizing criteria for each treatment unit and associated equipment (blowers, mixers, pumps, etc.) ❑ Total dynamic head (TDH) calculations and system curve analysis for each pump specified that is included in Section 4 C.6. ® Buoyancy calculations for all below grade structures. ❑ Supporting documentation that the specified auxiliary power source is capable of powering all essential treatment units. I. Permits NIA ® Provide the following information for each permit and/or certification required for this project: Not Permit/Certification Applicable Permit/ If Not Issued Provide Date Date Certification Status and Expected Submitted Approved Number Issuance Date Dam Safety N/A Soil Erosion and Sediment Control N/A USCOE /Section 404 Permit N/A Application for Authorization to Construct Permit (FORPA ATC -12-14) Page 4 Water Resources ENVIRONMENTAL QUALITY State of North Carolina Department of Environmental Quality Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14) Water Quality Certification (401) N/A USCOE / Section 10 N/A Stormwater Management Plan N/A CAMA N/A NCDOT Encroachment Agreement N/A Railroad Encroachment Agreement N/A Other N/A J. Residuals Management Plan ❑ For all new facilities, expanding facilities, or modifications that result in a change to sludge production and/or sludge processes, provide a Residuals Management Plan meeting the requirements of 15A NCAC 02T 0504(1) and 0508, the Plan must include- ❑ A detailed explanation as to how the generated residuals (including trash, sediment and grit) will be collected, handled, processed, stored, treated, and disposed. ❑ An evaluation of the treatment facility's residuals storage requirements based upon the maximum anticipated residuals production rate and ability to remove residuals. ❑ A permit for residuals utilization or a written commitment to the Applicant from a Permittee of a Department approved residuals disposal/utilization program that has adequate permitted capacity to accept the residuals or has submitted a residuals/utilization program application. ❑ If oil, grease, grit or screenings removal and collection is a designated unit process, a detailed explanation as to how the oil/grease will be collected, handled, processed, stored and disposed ® Not Applicable SECTION 4: PROJECT INFORMATION Continue to operate existing wastewater treatment plan Replace existing CCC with new 356 gal precast concrete CCC Application for Authorization to Construct Permit (FORM ATC -12-14) Page 5 Water Resources ENVIRONMENTAL QUALITY State of North Carolina Department of Environmental Quality Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14) A. WASTEWATER TREATMENT PLANT FLOW INFORMATION — COMPLETE FOR NEW OR EXPANDING FACILITIES 1. Provide the following flow information: Application for Authorization to Construct Permit (FORM ATC -12-14) Page 6 Plant Flows Existing Plant Design N/A MGD Current NPDES Permit Limit N/A MGD Current Annual Average (past 12 months) N/A MGD For Past 12 Months: Start Date: End Date: For Past 24 Months: Start Date: End Date: Maximum Month N/A MGD N/A MGD Maximum Day N/A MGD N/A MGD Peak Hour N/A MGD N/A MGD Application for Authorization to Construct Permit (FORM ATC -12-14) Page 6 Water Resources ENVIRONMENTAL QUALITY State of North Carolina Department of Environmental Quality Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14) B. WASTEWATER TREATMENT FACILITY DESIGN INFORMATION — COMPLETE FOR NEW OR EXPANDING FACILITIES AND FOR TREATMENT PROCESS MODIFICATIONS 1 Have all of the requirements of 15 NCAC 02H 0100, 15A NCAC 02T, North Carolina General Statute 133-3, North Carolina General Statute 143-215.1 and Division of Water Resources Minimum Design Criteria for NPDES Wastewater Treatment Facilities been met by the proposed design and specifications? ® Yes or ❑ No. If no, provide justification as to why the requirements are not met, consistent with 15A NCAC 02T 0105(n): 2 Provide the design influent and effluent characteristics that are used as the basis for the project design, and the NPDES permit limits for the following parameters: Based on the "Project Basis of Design" parameters listed above, will the proposed design allow the treatment facility to meet the NPDES Permit Limits listed above? ® Yes or ❑ No. If no, describe how and why the Permit Limits will not be met 4 Per 15A NCAC 02T 0505(1), by-pass and overflow lines are prohibited. Is this condition met by the design? ® Yes or ❑ No If no, describe the treatment units bypassed, why this is necessary, and where the bypass discharges: Application for Authorization to Construct Permit (FORM ATC -12-14) Page 7 Project Basis of Design Design Influent Design Influent Influent Concentration Load Concentration - (Must be (Must be Current Annual supported by supported by Average (past Engineering Engineering Design Effluent 12 months) if Calculations Calculations Concentration and/or NP DES Permit Limits Parameter Available [Section 3.H]) [Section 3.H]) Load (monthly average) Ammonia Nitrogen mg/L Summer mg/L Summer (NH3-N) mg/L mg/L Ib/day mg/L Winter mg/L Winter Biochemical mg/L Summer 30 0 mg/L Summer Oxygen Demand mg/L mg/L Ib/day (BODS) mg/L Winter mg/L Winter Fecal Coliform per 100 mL 200 per 100 mL Nitrate + Nitrite Nitrogen (NOB -N + mg/L mg/L NO2-N) Total Kjeldahl mg/L Nitrogen mg/L mg/L Total Nitrogen Ib/year Ib/year mg/L mg/L Total Phosphorus mg/L mg/L Ib/day Ib/year Ib/year Total Suspended Solids (TSS) mg/L mg/L Ib/day mg/L 30 0 mg/L Based on the "Project Basis of Design" parameters listed above, will the proposed design allow the treatment facility to meet the NPDES Permit Limits listed above? ® Yes or ❑ No. If no, describe how and why the Permit Limits will not be met 4 Per 15A NCAC 02T 0505(1), by-pass and overflow lines are prohibited. Is this condition met by the design? ® Yes or ❑ No If no, describe the treatment units bypassed, why this is necessary, and where the bypass discharges: Application for Authorization to Construct Permit (FORM ATC -12-14) Page 7 Water Resources ENVIRONMENTAL QUALITY State of North Carolina Department of Environmental Quality Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14) S. Per 15A NCAC 02T .0505(k), multiple pumps shall be provided wherever pumps are used. Is this condition met by the design? ❑ Yes or ❑ No. If no, provide an explanation: 6. Per 15A NCAC 02T .0505(1), power reliability shall be provided consisting of automatically activated standby power supply onsite capable of powering all essential treatment units under design conditions, or dual power supply shall be provided per 15A NCAC 02H. 0124(2)(a). Is this condition met by the design? ® Yes or ❑ No If no, provide (as an attachment to this Application) written approval from the Director that the facility* ➢ Has a private water supply that automatically shuts off during power failures and does not contain elevated water storage tanks, and ➢ Has sufficient storage capacity that no potential for overflow exists, and ➢ Can tolerate septic wastewater due to prolonged detention. 7. Per 15A NCAC 02T .0505(0), a minimum of 30 days of residual storage shall be provided. Is this condition met by the design? ❑ Yes or ❑ No. If no, explain the alternative design criteria proposed for this project in accordance 15A NCAC 02T .105(n): 8. Per 15A NCAC 02T .0505(9), the public shall be prohibited from access to the wastewater treatment facilities. Explain how the design complies with this requirement: 9. Is the treatment facility located within the 100 -year flood plain? ❑ Yes or ® No. If yes, describe how the facility is protected from the 100 -year flood: C. WASTEWATER TREATMENT UNIT AND MECHANICAL EQUIPMENT INFORMATION —COMPLETE FOR NEW OR EXPANDING FACILITIES AND FOR MODIFIED TREATMENT UNITS 1 PRELIMINARY AND PRIMARY TREATMENT (i.e, physical removal operations and flow equalization) - Treatment Unit No. of Type Size per Unit Plan Sheet Specification Calculations Provided? Units Reference Reference (Yes or No) Manual Bar Screen MGD at peak hourly flow Mechanical Bar Screen MGD at peak hourly flow Grit Removal MGD at peak hourly flow Flow Equalization -- gallons Primary Clarifier Circular ft diameter; ft side water depth Primary Clarifier Rectangular square feet; ft side water depth Other i I I Application for Authorization to Construct Permit (FORM ATC -12-14) Page 8 Water Resources ENVIRONMENTAL QUALITY State of North Carolina Department of Environmental Quality Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14) 2. SECONDARY TREATMENT (BIOLOGICAL REACTORS AND CLARIFIERS) (i e, biological and chemical processes to remove organics and nutrients) 3 TERTIARY TREATMENT No. of Plan Sheet Specification Calculations Treatment Unit Units Type Size per Unit Reference Reference Provided? (Yes or No) Aerobic Zones/ Circular ft diameter; ft side Tanks (Parallel; in gallons Anoxic Zones/ Rectangular square feet; ft side Tanks gallons Anaerobic 1 tablet (Gas; tablet; liquid) square feet C -1,C-2 - YES Zones/Tanks gallons Sequencing Batch square feet Reactor (SBR) -- gallons Membrane gallons Bioreactor (MBR) -- gallons Secondary Clarifier Circular ft diameter; ft side water depth Secondary Clarifier Rectangular square feet; ft side water depth Other 3 TERTIARY TREATMENT 4. DISINFECTION No. of Plan Sheet Specification Calculations Treatment Unit Units Type Size per Unit Reference Reference Provided? (Yes or No) Tertiary Clarifier Circular ft diameter; ft side Ultraviolet Light (Parallel; in water depth Tertiary Clarifier Rectangular square feet; ft side water depth Tertiary Filter 1 tablet (Gas; tablet; liquid) square feet C -1,C-2 - YES Tertiary Membrane Filtration square feet Post -Treatment Flow Equalization gallons Post -Aeration gallons Other 4. DISINFECTION Application for Authorization to Construct Permit (FORM ATC -12-14) Page 9 No. of Plan Sheet Specification Calculations Treatment Unit Units Type Size per Unit Reference Reference Provided? (Yes or No) gal/day per bank at peak Ultraviolet Light (Parallel; in hourly flow; number ofbanks, series) number of lamps/bank Chlorination 1 tablet (Gas; tablet; liquid) 325 gallons of contact tank/unit C -1,C-2 - YES Application for Authorization to Construct Permit (FORM ATC -12-14) Page 9 Water Resources ENVIRONMENTAL QUALITY State of North Carolina Department of Environmental Quality Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14) Dechlorination No. of (Gas; gallons of contact I Plan Sheet Specification Calculations Provided? GPM Units tablet, liquid) tank/unit Reference Reference 5. RESIDUALS TREATMENT Treatment Unit No. of Type Size per Unit Plan Sheet Specification Calculations Provided? GPM Units Reference Reference (Yes or No) Gravity Thickening square feet, ft side Tank water depth Mechanical Thickening/ dry Ib/hour Dewatering Aerobic Digestion gallons Anaerobic Digestion gallons Composting dry Ib/hour Drying dry Ib/hour Other 6. PUMP SYSTEMS (include influent, intermediate, effluent, mayor recycles, waste sludge, thickened waste sludge and plant drain pumps) Location No. of Pumps Purpose Type Capacity of each pump Plan Sheet Reference Specification Reference GPM TDH 7. MIXERS Location No. of Mixers Purpose Type Power of h M each Mixer Plan Sheet Reference Specification Reference Application for Authorization to Construct Permit (FORM ATC -12-14) Page 10 Water Resources ENVIRONMENTAL QUALITY State of North Carolina Department of Environmental Quality Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14) Application for Authorization to Construct Permit (FORM ATC -12-14) Page 11 Water Resources ENVIRONMENTAL QUALITY 8. BLOWERS State of North Carolina Department of Environmental Quality Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14) Location No. of Blowers Purpose Type Capacity of plan Sheet Specification each Blower Reference Reference (CFM) Specification Reference Requirement met by the Design? If "No", identify Treatment/Storage Setback Waivers in Item D.2 Unit Below Any habitable residence or place of assembly under separate 100 ft ® Yes r__ i ownership or not to be maintained as part of the project site —7— Any private or public water supply source 100 ft ❑ Yes ❑ No 9. ODOR CONTROL Location No. of Units Purpose Type Plan Sheet Reference Specification Reference Requirement met by the Design? If "No", identify Treatment/Storage Setback Waivers in Item D.2 Unit Below Any habitable residence or place of assembly under separate 100 ft ® Yes r__ i ownership or not to be maintained as part of the project site —7— D. SETBACKS —.COMPLETE FOR NEW WASTEWATER TREATMENT STRUCTURES The minimum distance for each setback parameter to the wastewater treatment/storage units per 15A NCAC 02T .0506(b) are as follows. 2. Have any setback waivers been obtained per 15A NCAC 02T 0506(d)? ❑ Yes or ® No If yes, have these waivers been written, notarized and signed by all parties involved and recorded with the County Register of Deeds? ❑ Yes or ❑ No. If no, provide an explanation. NOT APPLICABLE, ALL SETBACKS ARE MET FOR EXSITING WWTP Application for Authorization to Construct Permit (FORM ATC -12-14) Page 12 Minimum Distance Is Minimum Distance Setback Parameter Required from Nearest Requirement met by the Design? If "No", identify Treatment/Storage Setback Waivers in Item D.2 Unit Below Any habitable residence or place of assembly under separate 100 ft ® Yes ❑ No ownership or not to be maintained as part of the project site Any private or public water supply source 100 ft ❑ Yes ❑ No Surface waters (streams — intermittent and perennial, perennial Soft ❑ Yes ® No waterbodies, and wetlands) Any well with exception of monitoring wells 100 ft ❑ Yes ❑ No Any property line Soft ® Yes ❑ No 2. Have any setback waivers been obtained per 15A NCAC 02T 0506(d)? ❑ Yes or ® No If yes, have these waivers been written, notarized and signed by all parties involved and recorded with the County Register of Deeds? ❑ Yes or ❑ No. If no, provide an explanation. NOT APPLICABLE, ALL SETBACKS ARE MET FOR EXSITING WWTP Application for Authorization to Construct Permit (FORM ATC -12-14) Page 12 State of North Carolina Kill", Department of Environmental Quality Division of Water Resources Water Resources ENVIRONMENTAL QUALITY APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14) SECTION 5: APPLICATION CERTIFICATION BY PROFESSIONAL ENGINEER Professional Engineer's Certification per 15A NCAC 02T.0105: I, Michael R. Goforth, attest that this application package for an Authorization to Construct (Typed Name of Professional Engineer) for the Briarwood Subdivision WWTP - Chlorine Contact Chamber Replacement (Facility and Project Name) was prepared under my direct supervisory control and to the best of my knowledge is accurate, complete and consistent with the information supplied in the engineering plans, specifications, calculations, and all other supporting documentation for this project. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with all applicable regulations and statutes, 15 NCAC 02H. 0100, 15A NCAC 02T, North Carolina General Statute 133-3, North Carolina General Statute 143-215.1, and Division of Water Resources Minimum Design Criteria for NPDES Wastewater Treatment Facilities, and this Authorization to Construct Permit Application, except as provided for and explained in Section 4.6.1 of this Application. I understand that the Division of Water Resources' issuance of the Authorization to Construct Permit may be based solely upon this Certification and that the Division may waive the technical review of the plans, specifications, calculations and other supporting documentation provided in this application package. I further understand that the application package may be subject to a future audit by the Division. Although certain portions of this submittal package may have been prepared, signed and sealed by other professionals licensed in North Carolina, inclusion of these materials under my signature and seal signifies that I have reviewed the materials and have determined that the materials are consistent with the project design. I understand that in accordance with General Statutes 143-215.6A and 143-215.66, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal with written signature placed over or adjacent to the seal and dated: High Country Engineering, PC (C-3347) 41 Clayton Street, Suite 300 Asheville, NC 28801 T: 828.231.9380 Contact: Michael R. Goforth, PE E: mgoforth@hcepc.net Application for Authorization to Construct Permit (FORM ATC -12-14) Page 13 State of North Carolina Department of Environmental Quality Division of Water Resources Water Resources ENVIRONMENTAL QUALITY APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14) SECTION 6: APPLICATION CERTIFICATION BY APPLICANT Applicant's Certification per 15A NCAC 02T .0106(b): I, David Burnette. Ownerattest that this application package for an Authorization to Construct (Typed Name of Signature Authority and Title) for the Briarwood Subdivision WWTP - Chlorine Contact Chamber Replacement (Facility and Project Name) has been reviewed by me and is accurate and complete to the best of my knowledge. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. I further certify that in accordance with 15A NCAC 02T .0120(b), the Applicant or any affiliate has not been convicted of environmental crimes, has not abandoned a wastewater facility without proper closure, does not have an outstanding civil penalty where all appeals have been abandoned or exhausted, are compliant with any active compliance schedule, and does not have any overdue annual fees. I understand that the Division of Water Resources' issuance of the Authorization to Construct Permit may be based solely upon acceptance of the Licensed Professional Engineer's Certification contained in Section 5, and that the Division may waive the technical review of the plans, specifications, calculations and other supporting documentation provided in this application package. I further understand that the application package may be subject to a future audit. I understand that in accordance with General Statutes 143-215.6A and 143-215.613 any person who knowingly makes any false statem , ep ent on, o rtification in any application package shall be guilty of a Class 2 misdemeanor, which may incl de i t xc 00, as well as civil penalties up to $25,000 per violation. Signature: Date: _ It INal- THE COMPLETED APPLICATION AND SUPPORTING INFORMATION SHALL BE SUBMITTED TO: NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER RESOURCES/NPDES By U.S. Postal Service By Courier/Special Delivery: 1617 MAIL SERVICE CENTER 512 N. SALISBURY STREET, 9TH FLOOR RALEIGH, NORTH CAROLINA 27699-1617 RALEIGH, NORTH CAROLINA 27604 TELEPHONE NUMBER: (919) 807-6396 Application for Authorization to Construct Permit (FORM ATC -12-14) Page 14