Loading...
HomeMy WebLinkAbout20171407 Ver 1_Approval Letter_20171122Water Resources M Environmental Quality November 22, 2017 Piedmont Natural Gas Attn: Mr. Sanu Odugbesan 4720 Piedmont Row Drive Charlotte, NC 28210 ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Interim Director D W R # 17-1407 CRAVEN County Subject: APPROVAL OF 401 WATER QUALITY CERTIFICATION WITH ADDITIONAL CONDITIONS STATEN ROAD LAUNCHER/RECEIVER SITE Dear Mr. Odugbesan: You have our approval for the impacts listed below for the purpose described in your application dated November 2, 2017 and received by the Division of Water Resources (Division) on November 3, 2017. These impacts are covered by the attached Water Quality General Certification Number 4086 and the conditions listed below. This certification is associated with the use of Nationwide Permit Number 12 once it is issued to you by the U.S. Army Corps of Engineers. Please note that you should get any other federal, state or local permits before proceeding with your project, including those required by (but not limited to) Sediment and Erosion Control, Non -Discharge, and Water Supply Watershed regulations. This approval requires you to follow the conditions listed in the enclosed certification(s) or general permit and the following additional conditions: 1. The following impacts are hereby approved provided that all of the other specific and general conditions of the Certification are met. No other impacts are approved, including incidental impacts. [15A NCAC 02B .0506(b)(c)] Type of Impact Amount Approved Amount Approved Plan location/ (units) (units) Reference Permanent Temporary Attached Wetlands W1 (Fill Placement) 0.16 (acres) 0 (acres) Sheet 1 of 2 and W2 (Permanent Conversion) 0.03 (acres) 0 (acres) Sheet 6 of 11 W3 (Ground Disturbance) 0 (acres) 0.04 (acres) 2. This approval is for the purpose and design described in your application. The plans and specifications for this project are incorporated by reference as part of the Certification. If you change your project, you must notify the Division and you may be required to submit a new application package with the appropriate fee. If the property is sold, the new owner State of North Carolina I Environmental Quality I Water Resources -Water Quality Regional Operations Section -Washington Regional Office 943 Washington Square Mall, Washington, North Carolina 27889 252-946.6481 Staten Road Launcher/Receiver Site DWR# 17-1407 401APPROVAL Page 2 of 3 must be given a copy of this approval letter and General Certification and is responsible for complying with all conditions. [15A NCAC 02B .0507(d)(2)] 3. Water Quality Certification The proposed project must comply with all the conditions of the General Water Quality Certification(s) 4086. [15A NCAC 02B .0507(c)] 4. This approval and their conditions are final and binding unless contested. [G.S. 143-215.5] 5. This approval is for the purpose and design described in your application. The plans and specifications for this project are incorporated by reference as part of the Certification. If you change your project, you must notify the Division and you may be required to submit a new application package with the appropriate fee. If the property is sold, the new owner must be given a copy of this approval letter and General Certification and is responsible for complying with all conditions. [15A NCAC 02B .0507(d)(2)] These Certifications can be contested as provided in Articles 3 and 4 of General Statute 150B by filing a written petition for an administrative hearing to the Office of Administrative Hearings (hereby known as OAH). A petition form may be obtained from the OAH at http://www.ncoah.com/ or by calling the OAH Clerk's Office at (919) 431-3000 for information. Within sixty (60) calendar days of receipt of this notice, a petition must be filed with the OAH. A petition is considered filed when the original and one (1) copy along with any applicable OAH filing fee is received in the OAH during normal office hours (Monday through Friday between 8:OOam and S:OOpm, excluding official state holidays). The petition may be faxed to the OAH at (919) 431-3100, provided the original and one copy of the petition along with any applicable OAH filing fee is received by the OAH within five (5) business days following the faxed transmission. Mailing address for the OAH: If sending via US Postal Service: If sending via delivery service (UPS, FedEx, etc.): Office of Administrative Hearings Office of Administrative Hearings 6714 Mail Service Center 1711 New Hope Church Road Raleigh, NC 27699-6714 Raleigh, NC 27609-6285 One (1) copy of the petition must also be served to DEQ: William F. Lane, General Counsel Department of Environmental Quality 1601 Mail Service Center Raleigh, NC 27699-1601 Staten Road Launcher/Receiver Site DWR# 17-1407 401APPROVAL Page 3 of 3 This letter completes the review of the Division under section 401 of the Clean Water. Please contact Anthony Scarbraugh at 252-948-3924 or anthony.scarbraugh(@ncdenr.gov if you have any questions or concerns. Sincerely, David May, g ?pe Re io�Aisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ Enclosures: GC 4086 Certification of Completion cc: Gary Beecher, USACE Washington Regulatory Field Office (via email) Samir Dumpor, DEMLR WaRO DWR WaRO 401 File Laserfiche Joey Lawler, S&ME, Inc. (via email: jlawler@smeinc.com) VICIN FLARE SITE EASEMENI AREA TREE CLEARING ONLY - NO PERMANANT FILL PLACEMENT REQUIRED —OHP / OHP—OHP-j OHP—OHP—OHP•--OHP— __—____—___ 0 'Al / 112" REBAR FOUND N: 496,656.06 E: 2,550,322.36 NAD 83 (2011) I I I N PARCEL ID: B-210-010 W y y y y R„T`'J'�Q CARLILLIE S. PARKER, ET. AL. D.,.I ••• D.B. 1028 PG. 693 WETLAND PERMANENT CONVERSION AREA -1,313 SF/0.030 AC WETLAND PERMANENT IMPACT AREA - 6,984 SF/0.160 AC WETLAND TEMPORARY IMPACT AREA -1,797 SF/0.041 AC PARCEL ID: 8-210.6000 CHARLIE SIMMONS D.B. 1798 PG. 1040 y W W/ y W W W •Y y W 4� . W W y y W '4 W`• •V y W y W y W W•'y' y TLAND LO \'y .y' .. •Y •Y W .` y 'Y W W V• •Y •Y W t W W ••. �' .. Y y 'Y W y y J' y J' J' F2 ZD y y N• N• v *N34°34'03"E 125.17' y y y y e I �I I ZI I ZI S34°34'03"W 98.94' (TIE) — N34°34'03"E 290.02' WEj A y 35'PERMANENT EASEMENT AREA y y�� y� ! W W W •Y W / y y •P P_ OHP _OHP _ OHP_ OHP—OHP—OHP—OHP'--I—OHP—OHP—OHOHP� �./ w.. w^ ^•„ w^ .•..^ ^'•^—OHP—DNP-04iP—OHP-011P —OIIP—OHP—OHP—OHP —0HP—OHP—OIIP—OHP-0HP—DHP—OHP—OHP—OIIP—OHP—OHP—OHP—O P—ONP—ONP LEGEND COMPUTED POINT DB DEED BOOK PB . REBAR FOUND OR HOF L3,4- UNLESSSPECIFIED) M ELAT BOOK PAGE n IRONRODFOUND a. EXISTING GASMARKER NC FIRM LICENSE NO. C-1382 ____---- EASEMENT 1Y4N BY:JD REVISIONS SUBJECT BOUNDARY LINE1SURVEYEDI SUBJECT BOUNDARY LINE (NOTE URVEYE01 —AOJOINER BOUNDARY LIN (DT SURVEYED) PERMANENTT PERMANET V RWERAND WAY LINE — — • — — — EDGEOF WATER —SO— STORM DRAIN UNE OHP UTIU11E5 TEMPORARY WETLAND IMPACT r� CHAINNLINK 7lff11I I1101L /9vYYYYvv� TREE LINE L20 L16 y W�TIAq)Y / W �:91'/ APPROVED (TIE> North Carolina Environmental ��� Management Commission ,° Division of Water Resources Dpattre�T� !t 22- , 20/-7 PARCEL ID:9901t JAMES B. FIELDS AND WIFE, ADDIE FIELDS D.B. 1926 PG. 362 —OHP —OHP —OHP —OHP —ONE —OHP —OHP —OHP —OHP —OHP — --OLTP —OHP —OHP —OHP —OHP —OIIP —0HP _ —0HP-dIP-0HP—OIIP-0HP—OHP 0HP-0HP-0HP-0HP—OHP— I HEREBY CERTIFY THAT A SURVEY WAS MADE UNDER MY SUPERVISION AND THAT THE WETLANDS SHOWN HEREON REFLECTS THE DELINEATION EVIDENCE PROVIDED BY 88ME ENVIRONMENTAL SERVICES ON 04.12-2017 AND0030-2017. — 141") AL Piedmont 1. PIPE INSTALLATION THROUGH JURISDICTION BOUNDARY 8642 WEST MARKET STREET, SUITE 100 GREENSBORO, NORTH CAROLINA 27409 JURISDICTIONAL BOUNDARIES OF NC FIRM LICENSE NO. C-1382 LINE 204 STATEN RD UR CRAVEN COUNTY, NORTH CAROLINA 1Y4N BY:JD REVISIONS _ SEAL - I —4464 L PERMANENTT PERMANET V FILL CONVERSION = 5 RY 5, TEMPORARY WETLAND IMPACT 7lff11I I1101L L20 L16 y W�TIAq)Y / W �:91'/ APPROVED (TIE> North Carolina Environmental ��� Management Commission ,° Division of Water Resources Dpattre�T� !t 22- , 20/-7 PARCEL ID:9901t JAMES B. FIELDS AND WIFE, ADDIE FIELDS D.B. 1926 PG. 362 —OHP —OHP —OHP —OHP —ONE —OHP —OHP —OHP —OHP —OHP — --OLTP —OHP —OHP —OHP —OHP —OIIP —0HP _ —0HP-dIP-0HP—OIIP-0HP—OHP 0HP-0HP-0HP-0HP—OHP— I HEREBY CERTIFY THAT A SURVEY WAS MADE UNDER MY SUPERVISION AND THAT THE WETLANDS SHOWN HEREON REFLECTS THE DELINEATION EVIDENCE PROVIDED BY 88ME ENVIRONMENTAL SERVICES ON 04.12-2017 AND0030-2017. — 141") AL Piedmont SUIiVEYING &CONE'urrING REGIONAL LAND SURVEYORS, INC. [&yjj Natural Gas 8642 WEST MARKET STREET, SUITE 100 GREENSBORO, NORTH CAROLINA 27409 JURISDICTIONAL BOUNDARIES OF NC FIRM LICENSE NO. C-1382 LINE 204 STATEN RD UR CRAVEN COUNTY, NORTH CAROLINA 1Y4N BY:JD REVISIONS E taiDnU17 I NO. 1613.02 1 SCALE: V=30 IR# 2651465 SHEET 1 OF 2 N 1 1 \ LEGEND PROPOSED PIPE ABOVE GROUND \ , \A \ /'^\\ 111` `\ PROPOSED PIPE BELOWGROUND 11 V 1,,\ PROPOSED EWIPMENTBV OTHERS i PROPOSED TEMPORARY PIPE + + PROPOSED GRAVEL DRIVEWAY UISTING PIPE a/ a a + \alb 111 / ,• PROPOSEOPIPETOBEABANOONED EXISTING GRAVEL ROAD Na .3 4D PROPOSED GATE Np, Rea WITH PANIC BAR. + a r BROEOSED / PROPOSED FENCE aw4 +. 1a71 2 \N \ \ APPROVED a+a+a+"+.+a \ s `\North Carolina Environmental Mane yernent Commission ivisio i of Water Resources •• D e 1 z 20 L .., a a a \\\ 11 a a a a a" a+ PROPOSED GATE \II , eni # D WITH PANIC BAR / IT \1 i a2B.4 SCALE. I18'=1' PROPOSEDI6'GATE /T \ , ; NOTES. 1. ANYCHMGESRE0111REDDUETOFIELD I CONDITIONS MUST BE APPROVED BY THE ENGINEERING DEPARTMENT. J\. , `\\ 1\ I 2. ALL TIE-IN RELEVANT DIMENSIONSARE TO BE FIELD VERIFIED. PROPOSED EASMENT Z++ + d \ \ PROPOSED FLARE SITE i ®�y� / "" "" " \ 1 3. M4TERIALOUMPTIES ARE FINISHED OUANTINES, MATERIAL FOR TEsnrlcNOT lNauDED. 4. 4. TRANSITION FITTING SHAD BE MACHINED TO �I MATCH EXISTING PIPE PER PING SPECIFICATION MATCH318. S. NIGNTCAPSTOBEUSEDONALSECTIONSTHAT ARENOTTIEDIN. 5. INAREASOFSOLIf1ROCILPADDIRTSHALLBEUSEO FOR&ACKFILLTOREABOVEPIPE. 7. PIPETOBEWRAPPEDWITHFRPWREREIN m CONTACT WEN CONCRETE. & PIPEANDASSEMBLY NOT70M COME IN DIRECT CONTACT`t WITHCONCRETE. B. ALL UNDERGROUND Pl%NG SHALL BE COALED NwNSUr ErelgYSmNxs, Inc. NCEn2Mee4ml.".F4Q6 1171251a NERB,HU .d.,NC2B018 M INDICATES ELECTRICAL INSUVLTOR PROPRIETARY 8 CREAT RIGHTS RESERVED OR NOT SCALE THIS DRAWING DIMENSIONS ONLY REF. OW01&) PIEDMONT 'S NATURAL GAS FACILITY DRAWINGS ARECONSIDERED CONFIDENTIAL (OM-1895)'OMWNG IS CURRENT ONLY THROUGH THE LATEST REVISED DATE 'TOINSURE NEW IS NO RISK OF INAPPROPRIATE DISCLOSER ALL PREVIOUSPAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WIN RECOROS&INFO. MANAGEMENT 1RIM, POLICY TOM xo. Pyre q ] 11 E RIDWG LINE 204 MLV 16 SHEET(S) BOF 11 B•=, A 8-15-2011 ISSUE FOR REVIEW MH JM RP AREA CODE 1853 WE WA"`"ate' RE° AROJECTNUMEER Z EX°1H�q RSEDEOSCALE DWG DATE &1N1017 SINERSEDEO _ Piedmont 'I PROPOSED OVERVIEW ROJECT NUMBER 2857485 °n1 9°"' "'""' M°q TES "A W" ""�° °gAwlr]O 136 gEVIEION Natural Gas RAWINGBY MH M]EPXLYW XA GL°Jil NEW BERN, NC PNG -X-XXX-0000000 A ID 90'""""'""• PItlNCIPAL (.'KER IiTALS %.\X .Y XX EA'°INEEq PREFESSOWTATION 'BA/ARCHSTAMP cow. °PPx:E ]]n PePxax)Aorl%We Eq/,plpT)[, XC ]]]10 Resource Ce WN.x ,NC OIECIPLMEIRES'u1RCEfEN]ERILWENUMIEE