Loading...
HomeMy WebLinkAboutNC0026654_Inspection_20171122EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0026654 17/11/14 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Crossnore WWTP U.S. Highway 221 Crossnore NC 28616 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 10:00AM 17/11/14 15/04/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Jadd Wesley Brewer/ORC/828-898-6277/ Other Facility Data 10:20AM 17/11/14 20/01/31 Name, Address of Responsible Official/Title/Phone and Fax Number Edward T Vance,PO Box 129 Crossnore NC 286160129//828-733-0360/8287336393 Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Operations & Maintenance Facility Site Review Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Daniel J Boss ARO WQ//828-296-4658/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: 15D56055-D32F-4B87-8898-604072FA6A0E 11/22/2017 11/22/2017 NPDES yr/mo/day 17/11/14 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On 11/14/2017 Daniel Boss conducted a follow up inspection at the Crossnore WWTP. The follow up was in response to a bypass of about 1200 gallons that occurred from the UV disinfection channel on 10/09/2017. I met with Jadd Brewer and Steve Taylor at the plant. Jadd explained that the reason for the bypass of the UV disinfection system was very high plant flow due to I&I from a strong rain and probably a blockage in the discharge line from the UV channel. Jadd said that subsequent rainfall of similar magnitude has not resulted in additional bypass events, which is why he suspects a discharge line restriction must have occurred on the day of the bypass event. The UV channel sits at a lower elevation than the aeration system and clarifier, and the pressure from that drop could cause the channel to spill over with enough influent flow to the channel. The influent and effluent pipes from the UV channel are the same diameter and they are wide enough that I believe an obstruction to the effluent line was probably a factor causing the bypass. NC0026654 17 (Cont.) Page#2 DocuSign Envelope ID: 15D56055-D32F-4B87-8898-604072FA6A0E Permit:NC0026654 Inspection Date:11/14/2017 Owner - Facility: Inspection Type: Crossnore WWTP Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin’s surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/l) Comment: Disinfection - UV Yes No NA NE Are extra UV bulbs available on site? Are UV bulbs clean? Is UV intensity adequate? Is transmittance at or above designed level? Is there a backup system on site? Is effluent clear and free of solids? UV channel had a bypass on October 9, 2017, but Jadd says since that time, similar flows have not resulted in additional bypass events. Comment: Page#3 DocuSign Envelope ID: 15D56055-D32F-4B87-8898-604072FA6A0E