HomeMy WebLinkAbout20080680 Ver 1_More Info Letter_20090126W AT ?9QG Beverly Eaves Perdue, Governor
Dee Freeman, Secretary
North Carolina Department of Environment and Natural Resources
O < Coleen H. Sullins, Director
Division of Water Quality
January 26, 2009
DWQ Project # 08-0680
Moore County
CERTIFIED MAIL: RETURN RECEIPT REQUESTED
Mr. Ron Jackson
Quality Built Homes, Inc.
335 Fields Drive
Aberdeen, NC 28315-8611
Subject Property: Savannah's Garden Subdivision
Killets Creek [03061, 17-30-3-(1), WSIII, CA]
REQUEST FOR MORE INFORMATION
Dear Mr. Jackson:
On April 11, 2008, the Division of Water Quality (DWQ) received your application dated April 9, 2008,
to fill or otherwise impact 0.48 acres of 404/wetland to construct a residential development at the site. On
May 12, 2008, September 30, 2008, November 3, 2008, December 8, 2008, and January 9, 2009, the
DWQ received additional information from you, however, the DWQ has determined that your application
remains incomplete and/or provided inaccurate information as discussed below. The DWQ will require
additional information in order to process your application to impact protected wetlands and/or streams on
the subject property. Therefore, unless we receive five copies of the additional information requested
below, we will place this project on hold as incomplete until we receive this additional information. If we
do not receive the requested information, your project will be formally returned as incomplete. Please
provide the following information so that we may continue to review your project.
Additional Information Requested:
Please ensure that the weir that separates the high and low flows to the stormwater wetland is
correctly designed to direct the runoff from the one-inch storm into the wetland. The DWQ
recommends reconfiguring the inlet such that the swale receiving runoff from Drainage Area 4
discharges to the forebay of the stormwater wetland and the weir is placed on the opposite side of
the forebay. The DWQ believes that this design would more effectively separate the flows and
also would dissipate the energy of the runoff. Please provide the appropriate details and
calculations to support the design you select for the inlet structures.
2. Please show that the all discharges to the wetlands are at a non-erosive velocity of two feet per
second or less during the peak flow from the ten-year storm event.
3. The outlet device must be placed at the center of the micropool to reduce the chance of its being
clogged by vegetation.
NorthCarolina
401 Oversight/Express Review Permitting Unit MUMMY
1650 Mail Service Center, Raleigh, North Carolina 27699-1650
2321 Crabtree Boulevard, Suite 250, Raleigh, North Carolina 27604
Phone: 919-733-1786 / FAX 919-733-6893 / Internet: htt1) //h2o enr state nc.us/ncwetlands
An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper
Quality Built Homes, Inc.
Page 2 of 3
January 26, 2009
4. A seed mix may not be used in the planting plan for a stormwater wetland - please specify plants
or plugs for the herbaceous species.
5. Please provide ALL of the required items associated with the stormwater wetland planting plan,
including:
a. A depiction of the mature sizes and spacings for the plantings,
b. A specification of container sizes for the plantings,
c. The total number of each type of plant needed, and
d. A planting detail.
Please submit this information within 30 calendar days of the date of this letter. If we do not receive this
requested information within 30 calendar days of the date of this letter, your project will be withdrawn
and you will need to reapply with a new application and a new fee.
This letter only addresses the application review and does not authorize any impacts to wetlands, waters
or protected buffers. Please be aware that any impacts requested within your application are not
authorized (at this time) by the DWQ. Please call Ms. Cyndi Karoly or Mr. Ian McMillan at 919-733-
1786 if you have any questions regarding or would like to set up a meeting to disAi ss this matter.
Sine ly,
uk??s
Cyndi Karoly, Supervisor
401 Oversight/Express Review Permitting Unit
CBK/ijm
cc: Ken Averitte, DWQ Fayetteville Regional Office
Chad Turlington, DWQ Fayetteville Regional Office
Belinda Henson, DWQ Fayetteville Regional Office
Emily Burton, USACE Wilmington Regulatory Field Office
File Copy
Matt Matthews, DWQ Branch Manager
Jennifer Archambault, Dr. J.H. Carter & Associates, Inc., 515-F Midland Road, Southern Pines, NC 28387
Shelton Sullivan, DWQ Compliance and Enforcement
Phillip Reynolds, Attorney General's Office
Neal Smith Engineering, 139 Pinehurst Avenue, Suite C, Southern Pines, NC 28387
Filename: 080680Sava n nahsGa rdenSD(Moore)On_Hold6