Loading...
HomeMy WebLinkAboutNC0061719_Map_20171117 (5)ti N PROJECT NO.: P1558-001 DRAWING N0.: 001 WOO -D �A_K_ -------------- E I R NAD83 ( 201 1 ) N = 533,543.976 FT. E = 1 , 941 , 561 .008 FT. ID m 0 0 ENV TBM IRS#1 00 NAD83 ( 201 1 ) N = 533.640.460 FT. E = 1 , 941 , 733. 620 FT. NAVD88 ELEV.= 229.71 FT. SOIL DAM ROAD WW N 81-58-'51"E N 85o53/01// 31p•481'GRID E 310.51' — — — — ` S 73045'50"W 499.998'TL. GRID 100.00' I N 77°40'00'E 500.06'TL. II �� II � II 1 IIF IIS II i it I II I II � 11 I II i II I II � II II II FEE o e• S 780;01'08"W 499.89' _ r - D U - G A -D E I R NAD83 ( 201 1 ) N = 533,683.773 FT. E = 1,942,041.065 FT. NAVD88 ELEV.= 221.17 FT. .l W W r L° Qo Ln FINAL DRAWING -FOR REVEIW PURPOSES OO NLY- NOOT RELEASED FOR COO NSTRUCTION CAROLINA SHEET INDEX SHEET Cl COVERSHEET SHEET C2 EXISTING CONDITIONS SHEET C3 PROPOSED SITE PLAN SHEET C4 SITE GRADING PLAN SHEET C5 CLARIFIER, UV DETAILS SHEET C6 RAS/WAS DETAILS SHEET C7 HYDRAULIC PROFILE SHEET S1 STRUCTURAL DETAILS SHEET E1 ELECTRICAL PLAN SHEET E2 ELECTRICAL SCHEMATICS �NNuwuururrgr q E 5279 • • 1'Gf NEED J�•�o 70 l LI:NWOOD E. STROUD, P. . PROJECT NO.: P1558-001 DRAWING N0.: 002 EX. WATER METER S 73045'50"W 499.998'TL. GRID N 77040'00"E 500.06' TOTAL EIR BENT II EX. BACKFLOW II II I PREVENTOR � _ —.-----------------------------.--------------------- �" EX. GATE VALVE II I II I II I x II 1 II GRAVEL DRIVE AREA II I II I IIIIII EX. DROP INLET�(ll—(II— p v v EX, CHEMICAL BUILDING — II I \ REMOVE 11SECTION 2" EFFLUENTP OFIPE EX II 1 EX. AIR LINE \ VALVEATE TO BE REMOVED I \ — _ — — II -------------------- ........................:::::::::::::::................::::::::..::::::::::: r— — — EX MECHANICAL/ '— a ELECTRICAL BUILDING ... ......l,i.i.......... ..: ��:.�IIr.1,4�.an_rr,C:aar�','i,iiii,,,,r,r,��......r......,e rll,r,....... EX. ELECTRIC TRANSFORMER x II I I I II -0- v I DIGESTER I .VVC TO ATE BE REMOVED VALVE BRINE TANK II 35.000 GAL A I TO ----BE REMOVED —� II I I ---- ------ EX. CHLORINE I CONTACT TANK IREMOVE EX.2" PIPE INLETS (SEEIDETAIL U z I II w I 2—C3 ) II I z I I z IIJI :----EX. WATER LINE Z EX. YAR TO BE RELOCATED: U II I HYDRANTD a SEE SHEET C3 II I AERATION 3 x II I w I II I II I I 50,000 GAL „ II I x II I II OR 2 000 GAL II I I I I II I I II I I AERATION 2 II I ( 50,000 GAL II---_� II EX. YARD HYDRANT II II II II I I X II S 78001'08"W 499.89' GRAPHIC SCALE: 1"=10' FINAL DRAWING -FOR REVEIW PURPOSES ONLY - NOT RELEASED FOR CONSTRUCTION EX. EFFLUENT DISCHARGE PIPE \\\`,��)quunurruN o`O� H CAR0�''''% �•`��FESS��•��'L% # PE 5279 '��"�LQ�'GINEE�•OJ�� ` 00 'fffrff fff lilllN�`\` 7 /J/ LINWOOD E. STROUD, P.E. a BEFORE YOU DIG: NC ONE CALL (TOLL FREE) aOa (OR 1-600-632-4949) IT'S THE LAW: R E V I S I O N S I EIR BENT PROJECT NO.: P1558-001 DRAWING N0.: 004 x ----__ I -226__ _____________________ __-------------------------------------- \'----------------------------------------------- 133 000, � \ 1 _ I ,�, � 22 - .... ,,.,. � 5 .��._.----------2 _ S 73° 4,5=-5-b"W 499. 998' TL GRID 1 -_ _ ----�_ ---- ------------`70 - -_-_------ ____--- _ '----- N 7 40' 00"E �`•Ofl. 06r TOTS � ---- i S 78001'08"W GRAPHIC SCALE: 1"=10' it � EX. CHEMICAL BUILDING x -223--- \ ------------ II `_ II II I II I II I GRAVEL DRIVE AREA II I i I II - ------------------ f ! IIIA �' I N I II I I I EX. MECHANICAL/ I ELECTRICAL (�\ BUILDING I 1 1 I II II I ' ' i I ----J 'I I II ,- ---------_--' I 1 \ \ .00, - -------- 7 I ------ 225 .,.......--- S 78001'08"W GRAPHIC SCALE: 1"=10' it � EX. CHEMICAL BUILDING x -223--- FINAL DRAWING -FOR REVEIW PURPOSES ONLY - NOT RELEASED FOR CONSTRUCTION /CONTACT TANK / It It It / / / r I I 1 1 1 i 1 1 I 1 1 1 1 1 1 I I r ! ( 1 opH 11111111// f111,�i 0 "k ESS/6 # PE 5279 l LINWOOD E. STROUD. P.E. L BEFORE YOU DIG! NC ONE CALL (TOLL FREE) aOO (OR 1-800-632-4949) IT'S THE LAW! R E V I S I O N S \ ------------ FINAL DRAWING -FOR REVEIW PURPOSES ONLY - NOT RELEASED FOR CONSTRUCTION /CONTACT TANK / It It It / / / r I I 1 1 1 i 1 1 I 1 1 1 1 1 1 I I r ! ( 1 opH 11111111// f111,�i 0 "k ESS/6 # PE 5279 l LINWOOD E. STROUD. P.E. L BEFORE YOU DIG! NC ONE CALL (TOLL FREE) aOO (OR 1-800-632-4949) IT'S THE LAW! R E V I S I O N S 4" CO CO I Ir T A I I T A T M[ ,[ I I n 1 I l T CLARIFIER SECTION rT SCALE: 3/8"=1'-0" _C5 REMOVEABLE COVER PLATE (TYP) 4-64 UV PTP MODULE TRANSITION BOX 6 REQUIRED/BANK (TYP) 12" INLET - 12" ELECTRIC BUTTERFLY I VALVE WITH HANDLE STANDARD 3600K LEVEL CONTROL WEIR TRANS I T I ONT BO X I I%u%' I _ L PLANS, SHEET S-1 FOR FOUNDATION DETAILS 12" BUTTERFLY VALVE II t-41, 1 SOLID BLOCKING TOC 223.70 �J '{(BY OTHERS) =I I ri I El I F3 I F I I-' ° 12" DIP -- �: I I [-I I I i I I Illllll \_2" 9 NPT DRAIN L SEE STRUCTURAL PLANS, WITH PLUG (TYP) SHET S-1 FOR FOUNDATION DETAIL TROJAN MODEL. 3000 K DUAL UV FRONT VIEW SCALE: 3/8"=1'-0" PROJECT NO.: P1558-001 DRAWING NO.: 005 A C5 FINAL DRAWING -FOR REVEIW PURPOSES ONLY - HOU RELEASED FOR CONSTRUCTION 0 CLARIFIER SECTION SCALE: 3/8"=1'-0" VALVE LEGEND 1"4 LINWOOD E. STROUD, P. E. 2 C5 BEFORE YOU DIG! NC ONE CALL (TOLL FREE) aO0 (OR 1-800-632-4949) IT'S THE LAW! R E V I S I O N S GATE VALVE BUTTERFLY VALVE PVC DIAPHRAGM VALVE KA VN GLOBE VALVE 1"4 LINWOOD E. STROUD, P. E. 2 C5 BEFORE YOU DIG! NC ONE CALL (TOLL FREE) aO0 (OR 1-800-632-4949) IT'S THE LAW! R E V I S I O N S 10/1 Cl UV -1 PDR PROPOSED I DQ-------� 1 Cl UV -1 PDR CONTROLLEGEND 2-#2 1-#2 N., D--..0----�--_ " " PROPOSED PANEL B I 10/1 Cl UV-1^PDR COIL 480Y/277 VAC, I 010 HAND -OFF -AUTO SWITCH BONDING JUMPER 10/1C2 W-2 PDR 10/11 C2 UV 2 PDR D-----�i--o----�---- 1^ C2 UV -2 PDR 10/11 C2 UV -3 PDR 1^ C2 W-3 PDR D—..--—'�._ 1^ C2 W-3 PDR ELECTRICALLY OPERATED VALVE 1____ I N OLS I I I 10/1 j H CLAS I V1 j OPEN I I I I V114 CLOSE I I I I I I I L— — — — — — — — — — — ELECTRICALLY OPERATED VALVE 2 N OLS I 11-1 10/1 I I n j H CLOS I V2 I I I OPEN I V2j CLOSE It irl I i I I I I I L— — — — — — — — — — — ELECTRICALLY OPERATED VALVE 3 I N OLS I cl �--i 10/1 I I n j H CLS ; I V3 I I i OPEN I I I I V3 j CLOSE cCI \O I I I I I I I 3 PROPOSED I L1 I CONTROLLEGEND 2-#2 1-#2 N., TRANSFORMER " " PROPOSED PANEL B I OFF UTO T# COIL 480Y/277 VAC, I 010 HAND -OFF -AUTO SWITCH BONDING JUMPER 480 VAC PRI. NORMALLY OPEN - TIME TO CLOSE I T# 120/240 VAC SEC. TIME DELAY RELAY W/ 0 0 �0 CONTACT ADJUSTABLE TO TIME DELAY 0-60 MIN. 1 SELECTOR SWITCH 1-#10 GRD. LC. 6012 20/3 n .0 O COIL n 0 0 0/3 2n I I POWER CONTACTOR, 30A, 3-POLE,120VAC COIL 2011 2n 15/1 CIRCUIT BREAKER (� CONTACT I 0 0 I PROJECT NO.: P1558-001 DRAW I NG NO.: 010 OCOIL R# �I CONTACT + TIB N EXISTING EFFLUENT 4-20 MA -� FLOWMETER _ _,—, ,_-,_,_--- ,_._,_,; Y CONTROL RELAY Y INDICATOR LIGHT CONTROL NOTES: 1. COORDINATE CALIBRATION OF EXISTING EFFLUENT FLOW METER & CONFIGURE ANALOG INPUT HIGH FLOW RELAY SO THAT SECONDARY UV UNIT IS STARTED & ASSOCIATED ELECTRICALLY ACTUATED VALVE IS OPENED WHEN FLOW IS GREATER THAN 400 GPM. UV CONTROL PANEL SCHEMATIC SCALE: NONE e 5412,1412 N., & — 1412 GRD. IN 3/4"C. OC O MECHANICAUELECTRICAL ROOM ------------------------------------------------------, I I I I I I I I I I I I I I I I I I I EX. MCC ! I I I I I I I I I PROVIDE NEW 100A, 3 -POLE " " B EAKER IN 4 0 AC, 3 -POLE 100A MCC 1^ I 0 I I I I I I I I I I I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I L— ------ ---------------------•-----J METERING BUILDING i PROPOSED I I I PROPOSED PANEL "C"SINGLE-PHASE 2-#2 1-#2 N., TRANSFORMER " " PROPOSED PANEL B I 120/240 VAC, & 1-k SUPPLY SIDE "XFMR2", 25 KVA 480Y/277 VAC, I 1 -PHASE, 3-WIRE,100A BONDING JUMPER 480 VAC PRI. 3-PHASE, 4 -WIRE, 100A I I IN 1 1/2"C. 120/240 VAC SEC. I M $_ I 1 2011 1-#10 GRD. LC. 6012 20/3 n .0 IN 1" n I 2�1 0/3 2n I I I 2011 2n � I I 50/2 I I I I I I I I I I I I I I I I ------------- — ------------------ -------------- I I I I -------- z�9 4- co A adz PROPOSED UV CONTROL PANEL 3-#1 #6 GROUNDING ELECTRODE CONDUCTOR 1-#12.1412 10C. 1412,1412 N., ---e- & .,--`& 1412 GRD. IN 1/2"C. TYP. 3 PLACES -#12,1412 1/2'C. O EX. SERVICE CONDUCTORS CU M ri C7 N N cr c� 04 4p N 2 & 1412 GRD. IN 3/4" C. 6414 IN VC. TO DIALER UV INTENSITY SENSOR UV INTENSITY SENSOR EX. CT CABINET EX. METER EX. SERVICE DISCONNECT 480/277 VAC, 3 -POLE, 200A 150/3 EX. GENERATOR n 480/277 VAC, 3-PHASE D 0 125KVA,10OKW BLOWER CONTROL PANEL 1^ D O CLARIFIER CONTROL 1^ PANEL D O CLARIFIER CONTROL PANEL 1^ � O EX. GROUNDING ELECTRODE (IF ONE DOES NOT EXIST PROVIDE 2-3/4"X10' DRIVItN COPPER -CLAD RODS 6 FT. APART & BOND TO ALL OTHER AVAILABLE ELECTRODES PER NEC) NOTES: 1. WIRE LOW UV INTENSITY NORMALLY OPEN CONTACT TO EXISTING DIALER. PROGAM DIALER AS NECESSARY TO ALERT OPERATORS OF ALARM. UV INTENSITY SENSOR R E V I S I 0 N S PARTIAL POWER RISER SCALE: NONE 1 E2 �O FESS/pti9lq t 11 /13 1 ;Z_ L. MICHAEL STROUD, P.E. I PROJECT NO.: P1558-001 DRAWING N0.: 009 EX.GENERATOF EX. SERVICE — DISCONNECT EX. CT CABINET - EX. METER — EX. DIALER PANEL "'- I II I n / I ® f-====1=�a "xFMR EXiU'NG IILDINGI - II - _ _ _1• � II EX. MECHAN16AU -- _ ELECTRICAL ° II BUILDING f f I [EX. MCC I f fm— I I I I I I I I I I I I TYPE PLUG -ON MOUNTING SURFACE ENCLOSURE NE_ MAS_ PHASE 3 WIRE 4 VOLTS now277 MAIN 100AMCB FRAME 1ooA SHORT CIR.RATING 22,000 RMS SYM MIN o II CB TRIP DESCRIPTION SSE' BLOWER PANEROL ,3,5 � LOAD (AMPS) LOAD (AMPS) COND, WIRE CKT. GRND, DESCRIPTION CB TRIP SIZE LOAD (AMPS) LOAD (AMPS) A B A B COND. GRND. SIRE DESCRIPTION (") TII NO . CLARIFIER— CONTROL PANEL 2 ,9, CLARIFIER LLCONTROL PANEL 2 ELECTRICALLY OPERATED VALVES PANEL- B TYPE PLUG -ON MOUNTING SURFACE ENCLOSURE NE_ MAS_ PHASE 3 WIRE 4 VOLTS now277 MAIN 100AMCB FRAME 1ooA SHORT CIR.RATING 22,000 RMS SYM MIN CKT, NO. CB TRIP DESCRIPTION SSE' GRND, SIZE LOAD (AMPS) LOAD (AMPS) COND, WIRE CKT. GRND, DESCRIPTION CB TRIP SIZE LOAD (AMPS) LOAD (AMPS) A B A B COND. GRND. SIRE DESCRIPTION (") CB TRIP NO . 1 50/2 UV CONTROL PANEL 3 A B C A B C 0 SIZE NO. 1 20/3 BLOWER 3/4" (1)#12 (3#12 6 2 3/4" (1)#12 (3)#12 CLARIFIER CONTROL PANEL 2013 2 3 (1)#12 CONTROLPANEL 5 - BLANK 6 6 2 4 5 1/2" (1)#12 (2)#12 5 BLANK 6 2 6 7 20/3 CLARIFIER 3/4" (1)#12 (3#12 2 - - BLANK - 8 9 10 CONTROLPANEL - 3.1 - 2 - - BLANK 10 11 - 12 13 - BLANK - 2 - BLANK 12 13 6012 PANEL"C" 1" (1)#10 (2#2 22 - - BLANK - 14 15 - - - BLANK - 16 17 BLANK 22 - - BLANK 16 17 - BLANK - 18 - - BLANK - 18 19 - BLANK - - BLANK - - - BLANK - 20 21 - BLANK - - - - BLANK - 22 23 - BLANK - - - - - - -_ BLANK 24 25 24 BLANK - - - BLANK 26 27 - BLANK- 27 - BLANK _ - - - _ BLANK 28 29 IBLANK - 29 BLANK - BLANK 30 NOTES: NEUTRAL TERMINAL BAR QX GROUND TERMINAL BAR PANEL LOAD: A: 32A B: 32A C:10A PANEL- C TYPE PLUG -ON VOLTS 120/240 MAIN MOUNTING MLO SURFACE ENCLOSURE NEMA -1 FRAME 1o0A PHASE 1 WIRE 3 SHORT CIR.RATING 1000 RMS SYM MIN POWER NO CB TRIP DESCRIPTION SIZE' GRND. SIZE LOAD (AMPS) LOAD (AMPS) A B A B COND. GRND. SIRE DESCRIPTION (") CB TRIP NO . 1 50/2 UV CONTROL PANEL 3 1" (1#10 (3#8 36 - 39 - BLANK BLANK - - 2 4 5 15/1 UV -1 MONITOR U2" (1)#12 (2#12 5 - BLANK 6 6 7 15/1 UV -2 MONITOR 1/2" (1)#12 (2)#12 5 BLANK - 8 9 15/1 W-3 MONITOR 1/2" (1)#12 (2#12 5 - - - BLANK 3 1 10 11 - BLANK - 3.1 - - - BLANK - 12 13 - BLANK - - - - - BLANK - 14 15 BLANK - - - - - BLANK - 16 17 BLANK - - BLANK 18 19 - BLANK - - - BLANK 20 21 - BLANK - - - BLANK - 22 23 - BLANK - - - - - BLANK - 24 25 BLANK - - - BLANK - 26 27 - BLANK _ - - - BLANK 28 29 BLANK - BLANK - 30 NOTES: PANEL LOAD: A: 43A B: 44A NEUTRAL TERMINAL BAR GROUND TERMINAL BAR fXj EQUIPMENT CONNECTION SCHEDULE SYMBOL DESCRIPTION QTY. POWER VOLT. PHASE FLA DISCONNECT OBLOWER 1 3 HP 460 3 4.4 BREAKER IN CONTROL PANEL OCLARIFIER DRIVE 1 0,5 HP 460 3 1.1 DISCONNECT IN MANUFACTURER SUPPLIED CONTROL PANEL OUV PDR 6 756 W 120 1 6.3 CORD & PLUG, PROVIDED BY UV SYSTEM MANUFACTURER OW MONITOR 2 600 W 120 1 5.0 BREAKER IN DISTRIBUTION PANEL OELECTRICALLY OPERATED VALVE 3 1 120 1 3.1 BREAKER IN UV CONTROL PANEL C C 18" DIAMETER CONCRETE ENCASEMENT AROUND 6" TREATED POST (TYP.) MATED 2X10 BOARDS STAINLESS STEEL RU -BOLTS TYPICAL 18" DIAMETER CONCRETE ENCASEMENT AROUND 6" TREATED POST (TYP.) CONTROL PANEL MOUNTING PLATFORM DETAIL SCALE: NONE 2 E1 SIZE TO FIT EQUIPMENT UV MONITOR e o 0 s , D D d d c7 •,d d ° 0 D • d d . j. d TREATED 2X10 BOARDS %" STAINLESS STEEL THRU-BOLTS TYPICAL 4"X4"X24" TYPE 0, 316 STAINLESS STEEL WIRE TROUGH W/ SCREW COVER POWER DISTRIBUTION RECEPTACLES, TYP. 3 PLACES 18" DIAMETER CONCRETE ENCASEMENT AROUND 6" TREATED POST (TYP.) UV RCPT. ._&_MONITOR MOUNTING DETAIL (TYP. SCALE: NONE 3 E1 L. MICHAEL STROUD, P.E. BEFORE YOU DIG! NC ONE CALL (TOLL FREE) FRT— (OR 1-800-632-4949) IT`S THE LAW! R E V I S I O N S