HomeMy WebLinkAboutNC0061719_Map_20171117 (6)ti
N
PROJECT NO.: P1558-001
DRAWING N0.: 001
E I R
NAD83 ( 201 1 )
N = 533,543.976 FT.
E = 1 , 941 , 561 .008 FT.
WOO -D �A_K_
--------------
� I
� I
� I
I
ID
m 0 0 ENV
TBM IRS#1 00
NAD83 ( 201 1 )
N = 533.640.460 FT.
E = 1 , 941 , 733. 620 FT.
NAVD88
ELEV.= 229.71 FT.
SOIL DAM ROAD
WW
N
81-58-'51"E
N 85o53/01// 31p•481'GRID
E 310.51'
— — — — ` S 73045'50"W 499.998'TL. GRID
100.00' I N 77°40'00'E 500.06'TL.
II ��
II �
II 1
IIF
IIS
II i
it I
II I
II �
11 I
II i
II I
II �
II
II
II
FEE
o e•
S 780;01'08"W 499.89'
_ r
- D
U - G A -D
E I R
NAD83 ( 201 1 )
N = 533,683.773 FT.
E = 1,942,041.065 FT.
NAVD88
ELEV.= 221.17 FT.
.l
W
W
r L°
Qo
Ln
FINAL DRAWING
-FOR REVEIW PURPOSES OO NLY-
NOOT RELEASED FOR
COO NSTRUCTION
CAROLINA
SHEET INDEX
SHEET Cl COVERSHEET
SHEET C2 EXISTING CONDITIONS
SHEET C3 PROPOSED SITE PLAN
SHEET C4 SITE GRADING PLAN
SHEET C5 CLARIFIER, UV DETAILS
SHEET C6 RAS/WAS DETAILS
SHEET C7 HYDRAULIC PROFILE
SHEET S1 STRUCTURAL DETAILS
SHEET E1 ELECTRICAL PLAN
SHEET E2 ELECTRICAL SCHEMATICS
�NNuwuururrgr q
E 5279
• • 1'Gf NEED J�•�o
70
l
LI:NWOOD E. STROUD, P. .
PROJECT NO.: P1558-001
DRAWING N0.: 002
EX. WATER METER
S 73045'50"W 499.998'TL. GRID
N 77040'00"E 500.06' TOTAL
EIR BENT
II EX. BACKFLOW
II II I PREVENTOR � _ —.-----------------------------.---------------------
�" EX. GATE VALVE
II I
II I
II I
x II 1
II GRAVEL DRIVE AREA
II I
II I
IIIIII EX. DROP INLET�(ll—(II—
p v v
EX, CHEMICAL
BUILDING
—
II I \
REMOVE
11SECTION
2" EFFLUENTP
OFIPE
EX
II 1 EX. AIR LINE \ VALVEATE
TO BE REMOVED I \ — _ — —
II -------------------- ........................:::::::::::::::................::::::::..:::::::::::
r— — — EX MECHANICAL/ '—
a
ELECTRICAL
BUILDING
... ......l,i.i.......... ..: ��:.�IIr.1,4�.an_rr,C:aar�','i,iiii,,,,r,r,��......r......,e rll,r,.......
EX. ELECTRIC
TRANSFORMER x II I I I
II -0- v
I DIGESTER I .VVC TO ATE
BE REMOVED VALVE
BRINE TANK
II 35.000 GAL
A I
TO
----BE REMOVED —�
II I I ---- ------ EX. CHLORINE
I CONTACT TANK
IREMOVE EX.2" PIPE
INLETS (SEEIDETAIL
U
z I
II
w I 2—C3 )
II I
z I I
z IIJI
:----EX. WATER LINE
Z EX. YAR
TO BE RELOCATED:
U II I HYDRANTD a SEE SHEET C3
II I
AERATION 3
x II I
w I
II I
II I I 50,000 GAL „
II I
x II
I
II
OR
2 000 GAL
II I I
I I
II I I
II I I AERATION 2
II I ( 50,000 GAL
II---_�
II EX. YARD
HYDRANT
II
II
II
II
I
I
X II
S 78001'08"W 499.89'
GRAPHIC SCALE: 1"=10'
FINAL DRAWING
-FOR REVEIW PURPOSES ONLY -
NOT RELEASED FOR
CONSTRUCTION
EX. EFFLUENT
DISCHARGE PIPE
\\\`,��)quunurruN
o`O� H CAR0�''''%
�•`��FESS��•��'L%
# PE 5279
'��"�LQ�'GINEE�•OJ�� `
00
'fffrff fff lilllN�`\`
7
/J/
LINWOOD E. STROUD, P.E.
a
BEFORE YOU DIG:
NC ONE CALL
(TOLL FREE)
aOa
(OR 1-600-632-4949)
IT'S THE LAW:
R E V I S I O N S
I
EIR BENT
PROJECT NO.: P1558-001
DRAWING N0.: 004
x
----__ I -226__ _____________________ __-------------------------------------- \'-----------------------------------------------
133 000,
� \ 1 _ I ,�, � 22 - .... ,,.,. � 5
.��._.----------2
_
S 73° 4,5=-5-b"W 499. 998' TL GRID
1
-_
_
----�_ ---- ------------`70 - -_-_------
____--- _ '----- N 7 40' 00"E �`•Ofl. 06r TOTS � ----
i
S 78001'08"W
GRAPHIC SCALE: 1"=10'
it �
EX. CHEMICAL
BUILDING
x
-223---
\
------------
II `_
II
II I
II I
II I
GRAVEL DRIVE AREA
II I
i
I
II
- ------------------
f
!
IIIA
�'
I
N
I
II
I I
I EX. MECHANICAL/
I
ELECTRICAL
(�\ BUILDING
I
1 1
I
II
II
I
'
'
i
I
----J
'I
I
II
,- ---------_--'
I
1
\ \
.00,
-
--------
7
I ------
225 .,.......---
S 78001'08"W
GRAPHIC SCALE: 1"=10'
it �
EX. CHEMICAL
BUILDING
x
-223---
FINAL DRAWING
-FOR REVEIW PURPOSES ONLY -
NOT RELEASED FOR
CONSTRUCTION
/CONTACT TANK
/
It
It
It
/
/
/
r
I
I
1
1
1
i
1
1
I
1
1
1
1
1
1
I
I
r
!
(
1
opH 11111111// f111,�i
0 "k ESS/6
# PE 5279
l
LINWOOD E. STROUD. P.E.
L
BEFORE YOU DIG!
NC ONE CALL
(TOLL FREE)
aOO
(OR 1-800-632-4949)
IT'S THE LAW!
R E V I S I O N S
\
------------
FINAL DRAWING
-FOR REVEIW PURPOSES ONLY -
NOT RELEASED FOR
CONSTRUCTION
/CONTACT TANK
/
It
It
It
/
/
/
r
I
I
1
1
1
i
1
1
I
1
1
1
1
1
1
I
I
r
!
(
1
opH 11111111// f111,�i
0 "k ESS/6
# PE 5279
l
LINWOOD E. STROUD. P.E.
L
BEFORE YOU DIG!
NC ONE CALL
(TOLL FREE)
aOO
(OR 1-800-632-4949)
IT'S THE LAW!
R E V I S I O N S
4"
CO
CO
I Ir T A I I T A T M[ ,[ I I n 1 I l T
CLARIFIER SECTION rT
SCALE: 3/8"=1'-0" _C5
REMOVEABLE COVER
PLATE (TYP)
4-64 UV PTP MODULE
TRANSITION BOX 6 REQUIRED/BANK
(TYP)
12" INLET -
12" ELECTRIC BUTTERFLY
I
VALVE WITH HANDLE
STANDARD 3600K LEVEL
CONTROL WEIR
TRANS I T I ONT BO X
I I%u%' I _ L PLANS,
SHEET S-1 FOR FOUNDATION
DETAILS
12" BUTTERFLY VALVE
II t-41,
1 SOLID BLOCKING TOC 223.70 �J '{(BY OTHERS)
=I I ri I El I F3 I F I I-' °
12" DIP -- �: I I [-I
I I i I I
Illllll
\_2" 9 NPT DRAIN L SEE STRUCTURAL PLANS,
WITH PLUG (TYP) SHET S-1 FOR FOUNDATION
DETAIL
TROJAN MODEL. 3000 K DUAL UV
FRONT VIEW
SCALE: 3/8"=1'-0"
PROJECT NO.: P1558-001
DRAWING NO.: 005
A
C5
FINAL DRAWING
-FOR REVEIW PURPOSES ONLY -
HOU RELEASED FOR
CONSTRUCTION
0
CLARIFIER SECTION
SCALE: 3/8"=1'-0"
VALVE LEGEND
1"4
LINWOOD E. STROUD, P. E.
2
C5
BEFORE YOU DIG!
NC ONE CALL
(TOLL FREE)
aO0
(OR 1-800-632-4949)
IT'S THE LAW!
R E V I S I O N S
GATE VALVE
BUTTERFLY VALVE
PVC DIAPHRAGM VALVE
KA
VN
GLOBE VALVE
1"4
LINWOOD E. STROUD, P. E.
2
C5
BEFORE YOU DIG!
NC ONE CALL
(TOLL FREE)
aO0
(OR 1-800-632-4949)
IT'S THE LAW!
R E V I S I O N S
10/1
Cl UV -1 PDR
PROPOSED
I
DQ-------�
1
Cl UV -1 PDR
CONTROLLEGEND
2-#2 1-#2 N.,
D--..0----�--_
" "
PROPOSED PANEL B I
10/1
Cl UV-1^PDR
COIL
480Y/277 VAC, I
010 HAND -OFF -AUTO SWITCH
BONDING JUMPER
10/1C2 W-2 PDR
10/11 C2 UV 2 PDR
D-----�i--o----�----
1^ C2 UV -2 PDR
10/11 C2 UV -3 PDR
1^ C2 W-3 PDR
D—..--—'�._
1^ C2 W-3 PDR
ELECTRICALLY OPERATED
VALVE 1____
I N OLS I
I I
10/1 j H CLAS
I
V1 j
OPEN I
I
I I
V114 CLOSE
I
I I
I I
I I
L— — — — — — — — — — —
ELECTRICALLY OPERATED
VALVE 2
N OLS I
11-1
10/1 I I
n j H CLOS
I
V2 I I
I OPEN I
V2j CLOSE
It irl
I
i I
I I
I I
L— — — — — — — — — — —
ELECTRICALLY OPERATED
VALVE 3
I N OLS I
cl
�--i
10/1 I I
n j H CLS ;
I
V3 I I
i OPEN I
I
I I
V3 j CLOSE
cCI
\O I I
I I I
I I
3
PROPOSED
I
L1
I
CONTROLLEGEND
2-#2 1-#2 N.,
TRANSFORMER
" "
PROPOSED PANEL B I
OFF
UTO
T#
COIL
480Y/277 VAC, I
010 HAND -OFF -AUTO SWITCH
BONDING JUMPER
480 VAC PRI.
NORMALLY OPEN - TIME TO CLOSE
I
T#
120/240 VAC SEC.
TIME DELAY RELAY W/
0 0
�0
CONTACT
ADJUSTABLE TO TIME DELAY
0-60 MIN.
1
SELECTOR SWITCH
1-#10 GRD.
LC.
6012 20/3
n
.0
O
COIL
n
0 0
0/3
2n
I
I
POWER CONTACTOR, 30A, 3-POLE,120VAC COIL
2011
2n
15/1 CIRCUIT BREAKER
(�
CONTACT
I
0 0
I
PROJECT NO.: P1558-001
DRAW I NG NO.: 010
OCOIL
R#
�I CONTACT
+ TIB
N EXISTING
EFFLUENT 4-20 MA -�
FLOWMETER _ _,—, ,_-,_,_--- ,_._,_,;
Y
CONTROL RELAY
Y INDICATOR LIGHT
CONTROL NOTES:
1. COORDINATE CALIBRATION OF EXISTING EFFLUENT FLOW METER & CONFIGURE
ANALOG INPUT HIGH FLOW RELAY SO THAT SECONDARY UV UNIT IS STARTED &
ASSOCIATED ELECTRICALLY ACTUATED VALVE IS OPENED WHEN FLOW IS GREATER
THAN 400 GPM.
UV CONTROL PANEL SCHEMATIC
SCALE: NONE
e
5412,1412 N., & —
1412 GRD. IN 3/4"C.
OC
O
MECHANICAUELECTRICAL ROOM
------------------------------------------------------,
I I
I I
I I
I I
I I
I I
I I
I I
I I
I EX. MCC
! I
I I
I I
I I
I I
PROVIDE NEW
100A, 3 -POLE " "
B EAKER IN 4 0 AC, 3 -POLE
100A
MCC 1^ I
0
I
I I
I I
I I
I I
I I
I I
1
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
L— ------ ---------------------•-----J
METERING BUILDING
i
PROPOSED
I
I
I PROPOSED PANEL "C"SINGLE-PHASE
2-#2 1-#2 N.,
TRANSFORMER
" "
PROPOSED PANEL B I
120/240 VAC,
& 1-k SUPPLY SIDE
"XFMR2", 25 KVA
480Y/277 VAC, I
1 -PHASE, 3-WIRE,100A
BONDING JUMPER
480 VAC PRI.
3-PHASE, 4 -WIRE, 100A I
I
IN 1 1/2"C.
120/240 VAC SEC.
I
M
$_ I
1
2011
1-#10 GRD.
LC.
6012 20/3
n
.0
IN 1"
n
I 2�1
0/3
2n
I
I
I
2011
2n
�
I
I 50/2
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
------------- —
------------------
--------------
I
I
I
I
--------
z�9
4- co
A adz
PROPOSED UV CONTROL PANEL
3-#1
#6 GROUNDING
ELECTRODE
CONDUCTOR
1-#12.1412
10C.
1412,1412 N., ---e-
&
.,--`& 1412 GRD. IN 1/2"C.
TYP. 3 PLACES
-#12,1412
1/2'C.
O
EX. SERVICE CONDUCTORS
CU
M
ri
C7
N
N
cr
c�
04
4p
N
2 & 1412 GRD. IN 3/4" C.
6414 IN VC.
TO DIALER
UV INTENSITY SENSOR
UV INTENSITY SENSOR
EX. CT CABINET
EX. METER
EX. SERVICE DISCONNECT
480/277 VAC, 3 -POLE, 200A
150/3 EX. GENERATOR
n 480/277 VAC, 3-PHASE
D 0 125KVA,10OKW
BLOWER
CONTROL
PANEL
1^
D O
CLARIFIER
CONTROL
1^ PANEL
D O
CLARIFIER
CONTROL
PANEL
1^
� O
EX. GROUNDING ELECTRODE
(IF ONE DOES NOT EXIST
PROVIDE 2-3/4"X10' DRIVItN
COPPER -CLAD RODS 6 FT.
APART & BOND TO ALL OTHER
AVAILABLE ELECTRODES PER
NEC)
NOTES:
1. WIRE LOW UV INTENSITY NORMALLY OPEN CONTACT
TO EXISTING DIALER. PROGAM DIALER AS NECESSARY
TO ALERT OPERATORS OF ALARM.
UV INTENSITY SENSOR R E V I S I 0 N S
PARTIAL POWER RISER
SCALE: NONE
1
E2
�O FESS/pti9lq
t
11 /13 1 ;Z_
L. MICHAEL STROUD, P.E.
I
PROJECT NO.: P1558-001
DRAWING N0.: 009
EX.GENERATOF
EX. SERVICE —
DISCONNECT
EX. CT CABINET -
EX. METER —
EX. DIALER
PANEL "'- I
II I n / I
® f-====1=�a
"xFMR EXiU'NG
IILDINGI -
II - _ _ _1• �
II EX. MECHAN16AU -- _
ELECTRICAL °
II BUILDING
f
f I
[EX. MCC I
f
fm—
I
I I
I I
I I
I I
I I
I
TYPE PLUG -ON MOUNTING SURFACE ENCLOSURE NE_ MAS_ PHASE 3 WIRE 4
VOLTS now277 MAIN 100AMCB FRAME 1ooA SHORT CIR.RATING 22,000 RMS SYM MIN
o
II
CB TRIP
DESCRIPTION
SSE'
BLOWER
PANEROL
,3,5
�
LOAD (AMPS) LOAD (AMPS) COND, WIRE CKT.
GRND, DESCRIPTION CB TRIP
SIZE
LOAD (AMPS) LOAD (AMPS)
A B A B
COND. GRND. SIRE DESCRIPTION
(")
TII
NO .
CLARIFIER—
CONTROL
PANEL
2
,9,
CLARIFIER
LLCONTROL
PANEL
2
ELECTRICALLY
OPERATED
VALVES
PANEL- B
TYPE PLUG -ON MOUNTING SURFACE ENCLOSURE NE_ MAS_ PHASE 3 WIRE 4
VOLTS now277 MAIN 100AMCB FRAME 1ooA SHORT CIR.RATING 22,000 RMS SYM MIN
CKT,
NO.
CB TRIP
DESCRIPTION
SSE'
GRND,
SIZE
LOAD (AMPS) LOAD (AMPS) COND, WIRE CKT.
GRND, DESCRIPTION CB TRIP
SIZE
LOAD (AMPS) LOAD (AMPS)
A B A B
COND. GRND. SIRE DESCRIPTION
(")
CB TRIP
NO .
1 50/2 UV CONTROL PANEL
3
A B C A B C 0 SIZE NO.
1
20/3
BLOWER
3/4"
(1)#12
(3#12
6 2 3/4" (1)#12 (3)#12 CLARIFIER CONTROL PANEL 2013 2
3
(1)#12
CONTROLPANEL
5 -
BLANK
6
6 2 4
5
1/2"
(1)#12
(2)#12
5
BLANK
6 2 6
7
20/3
CLARIFIER
3/4"
(1)#12
(3#12
2 - - BLANK - 8
9
10
CONTROLPANEL
-
3.1
-
2 - -
BLANK 10
11
-
12
13 - BLANK
-
2 - BLANK 12
13
6012
PANEL"C"
1"
(1)#10
(2#2
22 - - BLANK - 14
15
- -
- BLANK
-
16
17 BLANK
22 - - BLANK 16
17
-
BLANK
-
18
- - BLANK - 18
19
-
BLANK
- -
BLANK
-
- - BLANK - 20
21
-
BLANK
-
-
- - BLANK - 22
23
-
BLANK
-
-
- -
- - -_
BLANK 24
25
24
BLANK
-
-
- BLANK 26
27
-
BLANK-
27 - BLANK
_
-
- - _
BLANK 28
29
IBLANK
-
29 BLANK
- BLANK 30
NOTES:
NEUTRAL TERMINAL BAR QX
GROUND TERMINAL BAR
PANEL LOAD: A: 32A B: 32A C:10A
PANEL- C
TYPE PLUG -ON
VOLTS 120/240 MAIN
MOUNTING
MLO
SURFACE
ENCLOSURE NEMA -1
FRAME 1o0A
PHASE 1 WIRE 3
SHORT CIR.RATING 1000
RMS SYM MIN
POWER
NO CB TRIP DESCRIPTION
SIZE'
GRND.
SIZE
LOAD (AMPS) LOAD (AMPS)
A B A B
COND. GRND. SIRE DESCRIPTION
(")
CB TRIP
NO .
1 50/2 UV CONTROL PANEL
3
1"
(1#10
(3#8
36 -
39 -
BLANK
BLANK
-
-
2
4
5 15/1 UV -1 MONITOR
U2"
(1)#12
(2#12
5 -
BLANK
6
6
7 15/1 UV -2 MONITOR
1/2"
(1)#12
(2)#12
5
BLANK
-
8
9 15/1 W-3 MONITOR
1/2"
(1)#12
(2#12
5 -
- - BLANK
3 1
10
11 - BLANK
-
3.1
-
-
- BLANK
-
12
13 - BLANK
-
-
-
- - BLANK
-
14
15 BLANK
-
-
- -
- BLANK
-
16
17 BLANK
-
-
BLANK
18
19 - BLANK
-
- -
BLANK
20
21 - BLANK
-
-
- BLANK
-
22
23 - BLANK
-
-
- -
- BLANK
-
24
25 BLANK
-
- -
BLANK
-
26
27 - BLANK
_
-
- -
BLANK
28
29 BLANK
-
BLANK
-
30
NOTES:
PANEL LOAD: A: 43A B: 44A
NEUTRAL TERMINAL BAR
GROUND TERMINAL BAR
fXj
EQUIPMENT
CONNECTION
SCHEDULE
SYMBOL
DESCRIPTION
QTY.
POWER
VOLT.
PHASE
FLA
DISCONNECT
OBLOWER
1
3 HP
460
3
4.4
BREAKER IN CONTROL PANEL
OCLARIFIER
DRIVE
1
0,5 HP
460
3
1.1
DISCONNECT IN MANUFACTURER SUPPLIED CONTROL PANEL
OUV
PDR
6
756 W
120
1
6.3
CORD & PLUG, PROVIDED BY UV SYSTEM MANUFACTURER
OW
MONITOR
2
600 W
120
1
5.0
BREAKER IN DISTRIBUTION PANEL
OELECTRICALLY
OPERATED VALVE
3 1
120
1
3.1
BREAKER IN UV CONTROL PANEL
C
C
18" DIAMETER CONCRETE
ENCASEMENT AROUND 6"
TREATED POST (TYP.)
MATED 2X10 BOARDS
STAINLESS STEEL
RU -BOLTS TYPICAL
18" DIAMETER CONCRETE
ENCASEMENT AROUND 6"
TREATED POST (TYP.)
CONTROL PANEL MOUNTING PLATFORM DETAIL
SCALE: NONE
2
E1
SIZE TO FIT EQUIPMENT
UV
MONITOR
e o
0
s
, D D
d d
° D D
c7 •,d d
° 0 D
• d d
. j. d
TREATED 2X10 BOARDS
%" STAINLESS STEEL
THRU-BOLTS TYPICAL
4"X4"X24" TYPE 0, 316 STAINLESS STEEL WIRE
TROUGH W/ SCREW COVER
POWER DISTRIBUTION
RECEPTACLES, TYP. 3 PLACES
18" DIAMETER CONCRETE
ENCASEMENT AROUND 6"
TREATED POST (TYP.)
UV RCPT. ._&_MONITOR MOUNTING DETAIL (TYP.
SCALE: NONE
3
E1
L. MICHAEL STROUD, P.E.
BEFORE YOU DIG!
NC ONE CALL
(TOLL FREE)
FRT—
(OR
1-800-632-4949)
IT`S THE LAW!
R E V I S I O N S