HomeMy WebLinkAboutAtlantic Coast Pipeline - VS-31 Warren PD4646LPROPOSED 36" AP-2 PIPELINEPERMANENT R/WPERMANENT R/WPROPOSED
12' ACCESS ROAD
PROPOSED 50'X50'
VALVE SITE
STA. 7091+83
PAD EL. 140'
x x x x x
xxxxxx
xxxxxxxxxxxxxxx
139
140
140140
1397091+00
7092+00
10'
10'
SEE GRAVEL DETAIL
REMOTE VALVE
OPERATION PANEL TO BE
MOUNTED WITH SK-105 (4")
PIPE SUPPORT
(SEE NOTE 4)
3 4" BURIED CONDUIT
(SEE NOTE 1)
50' MONOPOLE
FOR MICROWAVE
COMMUNICATIONS
(SEE NOTE 3)
GRAVEL DETAIL 4"0 5/18/17 ALC ISSUED FOR CONSTRUCTION
CONTOUR INTERVAL : 1 FOOT
SURVEY DATUM
UTM ZONE 17, US FEET
SITE LOCATION
LAT 35° 06' 48.43''
LONG 78° 43' 44.33''
SEAL
APP. FOR CONST.:
SCALE:
APP. FOR BID:
CHECKED:
DRAWN:
DIR/FILE:
TOWN:COUNTY:DWG. NO.GROUP REV.
Engineering and Consulting, LLC
..INITIATIVE INNOVATIONINTEGRITY
STATE:
Atlantic Coast Pipeline, LLC
FOR:
GENERAL NOTES AND COMMENTS:SYM.DATE BY REVISION INFORMATION PROJECT/TASK APP.
925 White Oaks Blvd. Bridgeport, WV 26330 / Phone: (681) 842-3000
NC
36'' MAIN LINE VALVE ASSEMBLY
CUMBERLAND
DOM/ACP/VALVE SITES/AP-2/VS 31 WARREN/DRFT PD 4646L 2
ALC 5/18/17
DLM 5/18/17
JNJ 5/18/17
1'' = 10'
WARREN VALVE SITE
CENTERLINE STATION 7091+83
L E G E N D
CONTOUR140
FENCE
xxxRIGHT-OF-WAY
CONTOUR
ACP CENTER LINE
EDGE OF ROAD
FLOOD PLAIN REFERENCE
ZONE X IS AREA DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL
CHANCE FLOODPLAIN.
THE PROPERTY IS LOCATED IN ZONE X AS SHOWN ON THE
FLOOD INSURANCE RATE MAP, 3720048800J CUMBERLAND COUNTY, NC.
INCORPORATED AREAS. EFFECTIVE DATE JANUARY 5, 2007.
1 8/15/17 RLR ISSUED FOR CONSTRUCTION - UPDATE CENTERLINE PER FERC REV 0
2 9/1/17 KLA ADDED ELECTRICAL CONTRACTOR INSTALL INFO
1.) BURIED CONDUIT TO BE PVC COATED, PITTSBURGH STANDARD CONDUIT CO. PLASTI-BOND OR OCAL BLUE.
2.) VALVE ASSEMBLY SHALL NOT BE TESTED WITH THE MAINLINE. HYDROTEST AT THE FABRICATION SHOP
WILL BE THE FINAL TEST ON THE VALVE ASSEMBLY.
3.) MONOPOLE INSTALLATION TO BE COMPLETED BY ELECTRICAL CONTRACTOR, FOUNDATION DETAIL SHALL BE
PROVIDED BY MANUFACTURER.
TO BE COMPLETED BY ELECTRICAL CONTRACTOR.
4.) REMOTE VALVE PANEL AND POLE TO BE INSTALLED BY ELECTRICAL CONTRACTOR.
5.) CONCRETE FOUNDATIONS ARE REQUIRED TO BE PLACED ON UNDISTURBED SOIL.