Order Summary Report
Analytical Laboratory
Order Number: J15090357
Project Name:MAYO STEAM - AB GW ASSESSMENT SPECIATION
Lab Contact:Peggy Kendall
Date:10/7/2015
Customer Address:
Customer Name(s):Tim Hunsucker, Jerry Wylie,Brandon Russo, Kathy Webb, John Toepfer
Phone:
Report Authorized By:
(Signature)
Program Comments:
Please contact the Program Manager (Peggy Kendall) with any questions regarding this report.
Data Flags & Calculations:
Any analytical tests or individual analytes within a test flagged with a Qualifier indicate a deviation from the method quality
system or quality control requirement. The qualifier description is found at the end of the Certificate of Analysis (sample results)
under the qualifiers heading. All results are reported on a dry weight basis unless otherwise noted. Subcontracted data
included on the Duke Certificate of Analysis is to be used as information only. Certified vendor results can be found in the
subcontracted lab final report. Duke Energy Analytical Laboratory subcontracts analyses to other vendor laboratories that have
been qualified by Duke Energy to perform these analyses except where noted.
Data Package:
This data package includes analytical results that are applicable only to the samples described in this narrative. An estimation of
the uncertainty of measurement for the results in the report is available upon request. This report shall not be reproduced, except
in full, without the written consent of the Analytical Laboratory. Please contact the Analytical laboratory with any questions. The
order of individual sections within this report is as follows:
Job Summary Report, Sample Identification, Technical Validation of Data Package, Analytical Laboratory Certificate of Analysis,
Analytical Laboratory QC Reports, Sub-contracted Laboratory Results, Customer Specific Data Sheets, Reports &
Documentation, Customer Database Entries, Test Case Narratives, Chain of Custody (COC)
Certification:
The Analytical Laboratory holds the following State Certifications : North Carolina (DENR) Certificate #248, South Carolina
(DHEC) Laboratory ID # 99005. Contact the Analytical Laboratory for definitive information about the certification status of
specific methods.
Peggy Kendall
Page 1 of 37
Sample ID's & Descriptions:
Sample ID Plant/Station
Collection
Date and Time Collected By Sample Description
2015030430 MAYO STEAM 09-Sep-15 11:16 AM Synterra ABMW-04BR
2015030431 MAYO STEAM 09-Sep-15 2:37 PM Synterra ABMW-04
2015030432 MAYO STEAM 09-Sep-15 9:17 AM Synterra ABMW-04
2015030433 MAYO STEAM 09-Sep-15 1:07 PM Synterra ABMW-04D
2015030434 MAYO STEAM 09-Sep-15 Synterra MW-16D
2015030435 MAYO STEAM 09-Sep-15 11:55 AM Synterra MW-16BR
2015030436 MAYO STEAM 09-Sep-15 11:15 AM Synterra MW-16S
2015030437 MAYO STEAM 09-Sep-15 10:04 AM Synterra MW-16D-DUP
8 Total Samples
Page 2 of 37
COC and .pdf report are in agreement with sample totals
and analyses (compliance programs and procedures).
All Results are less than the laboratory reporting limits.
All laboratory QA/QC requirements are acceptable.
Yes No
Technical Validation Review
Checklist:
Yes No
Yes No
Report Sections Included:
Job Summary Report Sub-contracted Laboratory Results
Sample Identification Customer Specific Data Sheets, Reports, & Documentation
Technical Validation of Data Package Customer Database Entries
Analytical Laboratory Certificate of Analysis
Analytical Laboratory QC Report
Chain of Custody
Reviewed By:Peggy Kendall Date:10/7/2015
Electronic Data Deliverable (EDD) Sent Separately
Page 3 of 37
Certificate of Laboratory Analysis
This report shall not be reproduced, except in full.
Order # J15090357
2015030430
Collection Date: 09-Sep-15 11:16 AM
Site: ABMW-04BR
Matrix: GW_WW
Analyte Analysis Date/TimeMethodUnits Qualifiers RDLResult
Sample #:
AnalystDF
Speciation of an Element - (Analysis Performed by Brooks Rand Labs LLC)
Vendor Parameter Complete Vendor Method V_BRAND
Page 4 of 37
Certificate of Laboratory Analysis
This report shall not be reproduced, except in full.
Order # J15090357
2015030431
Collection Date: 09-Sep-15 2:37 PM
Site: ABMW-04
Matrix: GW_WW
Analyte Analysis Date/TimeMethodUnits Qualifiers RDLResult
Sample #:
AnalystDF
Speciation of an Element - (Analysis Performed by Brooks Rand Labs LLC)
Vendor Parameter Complete Vendor Method V_BRAND
Page 5 of 37
Certificate of Laboratory Analysis
This report shall not be reproduced, except in full.
Order # J15090357
2015030432
Collection Date: 09-Sep-15 9:17 AM
Site: ABMW-04
Matrix: GW_WW
Analyte Analysis Date/TimeMethodUnits Qualifiers RDLResult
Sample #:
AnalystDF
Speciation of an Element - (Analysis Performed by Brooks Rand Labs LLC)
Vendor Parameter Complete Vendor Method V_BRAND
Page 6 of 37
Certificate of Laboratory Analysis
This report shall not be reproduced, except in full.
Order # J15090357
2015030433
Collection Date: 09-Sep-15 1:07 PM
Site: ABMW-04D
Matrix: GW_WW
Analyte Analysis Date/TimeMethodUnits Qualifiers RDLResult
Sample #:
AnalystDF
Speciation of an Element - (Analysis Performed by Brooks Rand Labs LLC)
Vendor Parameter Complete Vendor Method V_BRAND
Page 7 of 37
Certificate of Laboratory Analysis
This report shall not be reproduced, except in full.
Order # J15090357
2015030434
Collection Date: 09-Sep-15
Site: MW-16D
Matrix: GW_WW
Analyte Analysis Date/TimeMethodUnits Qualifiers RDLResult
Sample #:
AnalystDF
Speciation of an Element - (Analysis Performed by Brooks Rand Labs LLC)
Vendor Parameter Complete Vendor Method V_BRAND
Page 8 of 37
Certificate of Laboratory Analysis
This report shall not be reproduced, except in full.
Order # J15090357
2015030435
Collection Date: 09-Sep-15 11:55 AM
Site: MW-16BR
Matrix: GW_WW
Analyte Analysis Date/TimeMethodUnits Qualifiers RDLResult
Sample #:
AnalystDF
Speciation of an Element - (Analysis Performed by Brooks Rand Labs LLC)
Vendor Parameter Complete Vendor Method V_BRAND
Page 9 of 37
Certificate of Laboratory Analysis
This report shall not be reproduced, except in full.
Order # J15090357
2015030436
Collection Date: 09-Sep-15 11:15 AM
Site: MW-16S
Matrix: GW_WW
Analyte Analysis Date/TimeMethodUnits Qualifiers RDLResult
Sample #:
AnalystDF
Speciation of an Element - (Analysis Performed by Brooks Rand Labs LLC)
Vendor Parameter Complete Vendor Method V_BRAND
Page 10 of 37
Certificate of Laboratory Analysis
This report shall not be reproduced, except in full.
Order # J15090357
2015030437
Collection Date: 09-Sep-15 10:04 AM
Site: MW-16D-DUP
Matrix: GW_WW
Analyte Analysis Date/TimeMethodUnits Qualifiers RDLResult
Sample #:
AnalystDF
Speciation of an Element - (Analysis Performed by Brooks Rand Labs LLC)
Vendor Parameter Complete Vendor Method V_BRAND
Page 11 of 37
18804 North Creek Parkway, Suite 100, Bothell, WA 98011 • T: 206-632-6206• F: 206-632-6017 • www.brooksapplied.com
October 6, 2015
Peggy Kendall
Duke Energy Analytical Laboratory
Mail Code MGO3A2 (Building 7405)
13339 Hagers Ferry Rd.
Huntersville, NC 28078
980-875-5848
Project: Duke Energy Progress Mayo Plant (LIMS# J15090357)
Ms. Kendall,
Attached is the report associated with eight (8) aqueous samples submitted for hexavalent
chromium and arsenic speciation analyses. The samples were received in a sealed cooler at
-0.5°C on September 10, 2015. Hexavalent chromium and arsenic speciation analyses were
performed by ion chromatography inductively coupled plasma dynamic reaction cell mass
spectrometry (IC-ICP-DRC-MS).
If you have any questions, please feel free to contact me at your convenience.
Sincerely,
Jeremy Maute
Project Manager
Brooks Applied Labs, LLC
Page 12 of 37
Brooks Applied Labs, LLC
Report prepared for:
Peggy Kendall
Duke Energy Analytical Laboratory
Mail Code MGO3A2 (Building 7405)
13339 Hagers Ferry Rd.
Huntersville, NC 28078
Project: Duke Energy Progress Mayo Plant (LIMS# J15090357)
October 6, 2015
1. Sample Reception
Eight (8) aqueous samples were submitted for hexavalent chromium and arsenic speciation
analyses. The samples were received in acceptable condition on September 10, 2015 in a
sealed container at a temperature of -0.5°C.
All samples were received in a laminar flow clean hood, void of trace metals contamination
and ultra-violet radiation, and were designated discrete sample identifiers. Sample fractions
requesting hexavalent chromium and arsenic speciation analyses were field filtered by the
client. Upon receipt the pH of each aqueous sample submitted for hexavalent chromium
analysis was checked to confirm the adequacy of the field-preservation with the buffer
solution provided by Brooks Applied Labs (BAL). An aliquot of each sample submitted for
hexavalent chromium analysis was decanted into a clean polypropylene tube. All hexavalent
chromium sample fractions were stored in a secure refrigerator maintained at a temperature
of 4oC, until the analyses could be performed.
An aliquot of each sample submitted for arsenic speciation analysis was decanted into a clean
polypropylene centrifuge tube; all filtrates and original bottles were then stored in a secure,
monitored refrigerator (maintained at a temperature of ≤6oC) until the analyses could be
performed.
2. Sample Preparation
All sample preparation is performed in laminar flow clean hoods known to be free from trace
metals contamination. All applied water for dilutions and sample preservatives are
monitored for contamination to account for any biases associated with the sample results.
Hexavalent Chromium Analysis by IC-ICP-DRC-MS Prior to analysis, an aliquot of each
sample was filtered with a syringe filter (0.45µm) and injected directly into a sealed
Page 13 of 37
autosampler vial. No further sample preparation was performed as any chemical alteration of
a sample may shift the equilibrium of the system, resulting in changes in speciation ratios.
Arsenic Speciation Analysis by IC-ICP-DRC-MS An aliquot of each sample was filtered
directly into a sealed autosampler vial. No further sample preparation was performed as a
buffered EDTA solution was provided by Brooks Applied Labs for field-preservation of the
submitted samples.
3. Sample Analysis
All sample analysis is preceded by a minimum of a five-point calibration curve spanning the
entire concentration range of interest. Calibration curves are performed at the beginning of
each analytical day. All calibration curves, associated with each species of interest, are
standardized by linear regression resulting in a response factor. All sample results are
instrument blank corrected to account for any operational biases associated with the
analytical platform.
Prior to sample analysis, all calibration curves are verified using second source standards
which are identified as initial calibration verification standards (ICV).
Ongoing instrument performance is identified by the analysis of continuing calibration
verification standards (CCV) and continuing calibration blanks (CCB) at a minimum interval
of every ten analytical runs.
Hexavalent Chromium Analysis by IC-ICP-DRC-MS Each sample for hexavalent chromium
analysis was analyzed by ion chromatography inductively coupled plasma dynamic reaction
cell mass spectrometry (IC-ICP-DRC-MS). An aliquot of each sample is injected onto an
anion exchange column and mobilized by a basic (pH > 7) gradient. The eluting chromium
species are then introduced into a radio frequency (RF) plasma where energy-transfer
processes cause desolvation, atomization, and ionization. The ions are extracted from the
plasma through a differentially-pumped vacuum interface and travel through a pressurized
chamber (DRC) containing a reaction gas which preferentially reacts with interfering ions of
the same target mass to charge ratios (m/z). A solid-state detector detects ions transmitted
through the mass analyzer and the resulting current is processed by a data handling system.
Retention times for each eluting species are compared to known standards for species
identification.
Arsenic Speciation Analysis by IC-ICP-DRC-MS Each sample was analyzed for arsenic
speciation via ion chromatography inductively coupled plasma dynamic reaction cell mass
spectrometry (IC-ICP-DRC-MS). Aliquots of each sample are injected onto an anion
exchange column and eluted isocratically. The eluting chromium species are then introduced
into a radio frequency (RF) plasma where energy-transfer processes cause desolvation,
atomization, and ionization. The ions are extracted from the plasma through a differentially-
pumped vacuum interface and travel through a pressurized chamber (DRC) containing a
reaction gas which preferentially reacts with interfering ions of the same target mass to
Page 14 of 37
charge ratios (m/z). A solid-state detector detects ions transmitted through the mass analyzer
and the resulting current is processed by a data handling system.
Retention times for each eluting species are compared to known standards for species
identification.
4. Analytical Issues
No significant analytical issues were encountered. With the exception noted below, all
quality control parameters associated with the samples were within acceptance limits.
The monomethylarsonic acid spike recovery for the laboratory fortified blank (LFB) sample
was greater than the upper control limit of 120% (at 127%). All monomethylarsonic acid
results in the batch were non-detects. An LFB recovery for monomethylarsonic acid that is
biased high should have no impact on associated results that are below the detection limit.
Consequently, no corrective actions were required and no qualification of data was
necessary.
The estimated method detection limit (eMDL) for hexavalent chromium is generated from
replicate analyses of the lowest standard in the calibration curve.
The eMDL values for arsenite, arsenate, monomethylarsonic acid, and dimethylarsinic acid
are generated using the standard deviation of replicate analyses of the lowest standard in the
calibration curve.
If you have any questions or concerns regarding this report, please feel free to contact me.
Sincerely,
Jeremy Maute
Project Manager
Brooks Applied Labs, LLC
Page 15 of 37
Project ID: DUK-HV1503Z
PM: Jeremy Maute
Client PM: Peggy Kendall
Client PO: 1217608
Definition of Data Qualifiers
(Effective 9/23/09)
Laboratory Accreditation
BRL is accredited by the National Environmental Laboratory Accreditation Program (NELAP) through the State of Florida
Department of Health, Bureau of Laboratories (E87982) and is certified to perform many environmental analyses. BRL is
also certified by many other states to perform environmental analyses. For a current list of our accreditations /certifications,
please visit our website at <http://www.brooksrand.com/about/accreditations-certifications/>. Results reported relate only to
the samples listed in the report.
Report Information
BLK
BRL
BS
CAL
CCV
D
DUP
ICV
MSD
ND
NR
PS
REC
RPD
RSD
SCV
SOP
method blank
Brooks Rand Labs
laboratory fortified blank
calibration standard
continuing calibration verification
dissolved fraction
duplicate
initial calibration verification
matrix spike duplicate
non-detect
non-reportable
post preparation spike
percent recovery
relative percent difference
relative standard deviation
secondary calibration verification
standard operating procedure
MDL
MRL
MS
method detection limit
method reporting limit
matrix spike
SRM
T
COC
standard reference material
total recoverable fraction
chain of custody record
Common Abbreviations
These qualifiers are based on those previously utilized by Brooks Rand Labs, those found in the EPA SOW ILM03.0,
Exhibit B, Section III, pg. B-18, and the USEPA Contract Laboratory Program National Functional Guidelines for Inorganic
Superfund Data Review; USEPA; January 2010. These supersede all previous qualifiers ever employed by BRL.
Detected by the instrument, the result is > the MDL but ≤ the MRL. Result is reported and considered an estimate.J
E An estimated value due to the presence of interferences. A full explanation is presented in the narrative.
H Holding time and/or preservation requirements not met. Result is estimated.
J-1 Estimated value. A full explanation is presented in the narrative.
J-M Duplicate precision (RPD) for associated QC sample was not within acceptance criteria. Result is estimated.
J-N Spike recovery for associated QC sample was not within acceptance criteria. Result is estimated.
M Duplicate precision (RPD) was not within acceptance criteria. Result is estimated.
N Spike recovery was not within acceptance criteria. Result is estimated.
R Rejected, unusable value. A full explanation is presented in the narrative.
U Result is ≤ the MDL or client requested reporting limit (CRRL). Result reported as the MDL or CRRL.
X Result is not BLK-corrected and is within 10x the absolute value of the highest detectable BLK in the batch.
Result is estimated.
Field Quality Control Samples
Please be notified that certain EPA methods require the collection of field quality control samples of an appropriate type
and frequency; failure to do so is considered a deviation from some methods and for compliance purposes should only be
done with the approval of regulatory authorities. Please see the specific EPA methods for details regarding required field
quality control samples.
IBL instrument blank
continuing calibration blankCCB not calculatedN/C
18804 North Creek Parkway, Suite 100, Bothell, WA 98011 · P(206) 632-6206 · F(206) 632-6017 · brl@brooksapplied.com · www.brooksapplied.com
Page 16 of 37
Project ID: DUK-HV1503Z
PM: Jeremy Maute
Client PM: Peggy Kendall
Client PO: 1217608
Sample Information
Report Matrix Type ReceivedSampledSampleLab IDAlias
N15I041-01ABMW-04BR 09/09/2015 09/10/2015SampleWater2015030430
N15I041-02ABMW-04 (9/9/15 14:37)09/09/2015 09/10/2015SampleWater2015030431
N15I041-03ABMW-04 (9/9/15 09:17)09/09/2015 09/10/2015SampleWater2015030432
N15I041-04ABMW-04D 09/09/2015 09/10/2015SampleWater2015030433
N15I041-05MW-16D 09/09/2015 09/10/2015SampleWater2015030434
N15I041-06MW-16D 09/09/2015 09/10/2015SampleWater2015030434
N15I041-07MW-16BR 09/09/2015 09/10/2015SampleWater2015030435
N15I041-08MW-16BR 09/09/2015 09/10/2015SampleWater2015030435
N15I041-09MW-16S 09/09/2015 09/10/2015SampleWater2015030436
N15I041-10MW-16S 09/09/2015 09/10/2015SampleWater2015030436
N15I041-11MW-16D-DUP 09/10/2015SampleWater09/09/20152015030437
N15I041-12MW-16D-DUP 09/10/2015SampleWater09/09/20152015030437
Batch Summary
Analyte Prepared Analyzed SequenceBatchLab Matrix Method
NC0004709/11/2015 09/12/2015 S150023IC-ICP-MSAs(III)Water
NC0004709/11/2015 09/12/2015 S150023IC-ICP-MSAs(V)Water
NC0010009/16/2015 09/17/2015 S150033EPA 7199 ModCr(VI)Water
NC0004709/11/2015 09/12/2015 S150023IC-ICP-MSDMAsWater
NC0004709/11/2015 09/12/2015 S150023IC-ICP-MSMMAsWater
18804 North Creek Parkway, Suite 100, Bothell, WA 98011 · P(206) 632-6206 · F(206) 632-6017 · brl@brooksapplied.com · www.brooksapplied.com
Page 17 of 37
Project ID: DUK-HV1503Z
PM: Jeremy Maute
Client PM: Peggy Kendall
Client PO: 1217608
Sample Results
Brooks Applied Labs
Sample Sequence Result MDL MRL Unit BatchQualifierAnalyte BasisReport Matrix
ABMW-04 (9/9/15 09:17), 2015030432
598D S150023NC00047Water2.160.551N15I041-03 As(III)µg/L
13.5D S150023NC00047Water2.160.406N15I041-03 As(V)µg/L
0.498D U S150023NC00047Water2.250.498N15I041-03 DMAs µg/L
0.310D U S150023NC00047Water2.280.310N15I041-03 MMAs µg/L
ABMW-04 (9/9/15 14:37), 2015030431
709D S150023NC00047Water2.160.551N15I041-02 As(III)µg/L
7.71D S150023NC00047Water2.160.406N15I041-02 As(V)µg/L
0.498D U S150023NC00047Water2.250.498N15I041-02 DMAs µg/L
0.310D U S150023NC00047Water2.280.310N15I041-02 MMAs µg/L
ABMW-04BR, 2015030430
0.551D U S150023NC00047Water2.160.551N15I041-01 As(III)µg/L
0.406D U S150023NC00047Water2.160.406N15I041-01 As(V)µg/L
0.498D U S150023NC00047Water2.250.498N15I041-01 DMAs µg/L
0.310D U S150023NC00047Water2.280.310N15I041-01 MMAs µg/L
ABMW-04D, 2015030433
107D S150023NC00047Water2.160.551N15I041-04 As(III)µg/L
8.08D S150023NC00047Water2.160.406N15I041-04 As(V)µg/L
0.498D U S150023NC00047Water2.250.498N15I041-04 DMAs µg/L
0.310D U S150023NC00047Water2.280.310N15I041-04 MMAs µg/L
MW-16BR, 2015030435
0.551D U S150023NC00047Water2.160.551N15I041-07 As(III)µg/L
0.406D U S150023NC00047Water2.160.406N15I041-07 As(V)µg/L
0.013D J S150033NC00100Water0.0510.007N15I041-08 Cr(VI)µg/L
0.498D U S150023NC00047Water2.250.498N15I041-07 DMAs µg/L
0.310D U S150023NC00047Water2.280.310N15I041-07 MMAs µg/L
MW-16D, 2015030434
0.551D U S150023NC00047Water2.160.551N15I041-05 As(III)µg/L
0.406D U S150023NC00047Water2.160.406N15I041-05 As(V)µg/L
0.066D S150033NC00100Water0.0510.007N15I041-06 Cr(VI)µg/L
0.498D U S150023NC00047Water2.250.498N15I041-05 DMAs µg/L
0.310D U S150023NC00047Water2.280.310N15I041-05 MMAs µg/L
18804 North Creek Parkway, Suite 100, Bothell, WA 98011 · P(206) 632-6206 · F(206) 632-6017 · brl@brooksapplied.com · www.brooksapplied.com
Page 18 of 37
Project ID: DUK-HV1503Z
PM: Jeremy Maute
Client PM: Peggy Kendall
Client PO: 1217608
Sample Results
Brooks Applied Labs
Sample Sequence Result MDL MRL Unit BatchQualifierAnalyte BasisReport Matrix
MW-16D-DUP, 2015030437
0.551D U S150023NC00047Water2.160.551N15I041-11 As(III)µg/L
0.406D U S150023NC00047Water2.160.406N15I041-11 As(V)µg/L
0.069D S150033NC00100Water0.0510.007N15I041-12 Cr(VI)µg/L
0.498D U S150023NC00047Water2.250.498N15I041-11 DMAs µg/L
0.310D U S150023NC00047Water2.280.310N15I041-11 MMAs µg/L
MW-16S, 2015030436
0.551D U S150023NC00047Water2.160.551N15I041-09 As(III)µg/L
0.406D U S150023NC00047Water2.160.406N15I041-09 As(V)µg/L
0.007D U S150033NC00100Water0.0510.007N15I041-10 Cr(VI)µg/L
0.498D U S150023NC00047Water2.250.498N15I041-09 DMAs µg/L
0.310D U S150023NC00047Water2.280.310N15I041-09 MMAs µg/L
18804 North Creek Parkway, Suite 100, Bothell, WA 98011 · P(206) 632-6206 · F(206) 632-6017 · brl@brooksapplied.com · www.brooksapplied.com
Page 19 of 37
Project ID: DUK-HV1503Z
PM: Jeremy Maute
Client PM: Peggy Kendall
Client PO: 1217608
Accuracy & Precision Summary
Batch: NC00047
Analyte Result UnitsNative Spike REC & Limits RPD & Limits
Method: IC-ICP-MS
Lab Matrix: Water
Sample
Laboratory Fortified Blank (NC00024)NC00047-BS1
5.000 103%µg/L 80-120As(III)5.173
5.000 101%µg/L 80-120As(V)5.039
3.198 104%µg/L 80-120DMAs3.340
Laboratory Fortified Blank (NC00025)NC00047-BS2
5.924 127%µg/L 80-120MMAs7.513
Duplicate (N15I014-05)NC00047-DUP1
µg/L 253%As(III)123.0126.8
µg/L 254%As(V)143.4148.9
µg/L 25N/CDMAsNDND
µg/L 25N/CMMAsNDND
Matrix Spike (N15I014-05)NC00047-MS1
216.0 93%µg/L 75-125As(III)328.3126.8
216.0 103%µg/L 75-125As(V)371.4148.9
225.1 98%µg/L 75-125DMAs219.9ND
227.7 109%µg/L 75-125MMAs248.0ND
Matrix Spike Duplicate (N15I014-05)NC00047-MSD1
216.0 96%µg/L 75-125 252%As(III)335.0126.8
216.0 102%µg/L 75-125 250.3%As(V)370.2148.9
225.1 98%µg/L 75-125 250.6%DMAs 221.3ND
227.7 111%µg/L 75-125 252%MMAs 252.8ND
18804 North Creek Parkway, Suite 100, Bothell, WA 98011 · P(206) 632-6206 · F(206) 632-6017 · brl@brooksapplied.com · www.brooksapplied.com
Page 20 of 37
Project ID: DUK-HV1503Z
PM: Jeremy Maute
Client PM: Peggy Kendall
Client PO: 1217608
Accuracy & Precision Summary
Batch: NC00100
Analyte Result UnitsNative Spike REC & Limits RPD & Limits
Method: EPA 7199 Mod
Lab Matrix: Water
Sample
Laboratory Fortified Blank (NC00338)NC00100-BS1
2.002 97%µg/L 80-120Cr(VI)1.950
Duplicate (N15I036-03)NC00100-DUP1
µg/L 259%Cr(VI)0.0200.021
Matrix Spike (N15I036-03)NC00100-MS1
5.102 98%µg/L 75-125Cr(VI)5.0380.021
Matrix Spike Duplicate (N15I036-03)NC00100-MSD1
5.102 99%µg/L 75-125 250.7%Cr(VI)5.0730.021
18804 North Creek Parkway, Suite 100, Bothell, WA 98011 · P(206) 632-6206 · F(206) 632-6017 · brl@brooksapplied.com · www.brooksapplied.com
Method Blanks & Reporting Limits
Batch: NC00100
Matrix: Water
Result Units
µg/L
µg/L
-0.001
0.002
µg/L
Method: EPA 7199 Mod
Analyte: Cr(VI)
Sample
NC00100-BLK1
NC00100-BLK2
NC00100-BLK3
NC00100-BLK4 µg/L
-0.0003
-0.001
MRL: 0.051 MDL: 0.007
Page 21 of 37
Project ID: DUK-HV1503Z
PM: Jeremy Maute
Client PM: Peggy Kendall
Client PO: 1196750
Method Blanks & Reporting Limits
Batch: NC00047
Method: IC-ICP-MS
Matrix: Water
Analyte: As(III)
Result UnitsSample
NC00047-BLK1 µg/L0.00
NC00047-BLK2 µg/L0.00
NC00047-BLK3 µg/L0.00
NC00047-BLK4 µg/L0.00
MDL: 0.551Average: 0.000 Standard Deviation: 0.000
Limit: 0.367Limit: 1.101 MRL: 2.16
Analyte: As(V)
Result UnitsSample
NC00047-BLK1 µg/L0.00
NC00047-BLK2 µg/L0.00
NC00047-BLK3 µg/L0.00
NC00047-BLK4 µg/L0.00
MDL: 0.406Average: 0.00 Standard Deviation: 0.00
Limit: 0.27Limit: 0.81 MRL: 2.16
Analyte: DMAs
Result UnitsSample
NC00047-BLK1 µg/L0.00
NC00047-BLK2 µg/L0.42
NC00047-BLK3 µg/L0.00
NC00047-BLK4 µg/L0.00
MDL: 0.498Average: 0.11 Standard Deviation: 0.21
Limit: 0.33Limit: 1.00 MRL: 2.25
18804 North Creek Parkway, Suite 100, Bothell, WA 98011 · P(206) 632-6206 · F(206) 632-6017 · brl@brooksapplied.com · www.brooksapplied.com
Page 22 of 37
Project ID: DUK-HV1503Z
PM: Jeremy Maute
Client PM: Peggy Kendall
Client PO: 1196750
Method Blanks & Reporting Limits
Analyte: MMAs
Result UnitsSample
NC00047-BLK1 µg/L0.00
NC00047-BLK2 µg/L0.00
NC00047-BLK3 µg/L0.00
NC00047-BLK4 µg/L0.00
MDL: 0.310Average: 0.00 Standard Deviation: 0.00
Limit: 0.21Limit: 0.62 MRL: 2.28
18804 North Creek Parkway, Suite 100, Bothell, WA 98011 · P(206) 632-6206 · F(206) 632-6017 · brl@brooksapplied.com · www.brooksapplied.com
Page 23 of 37
Project ID: DUK-HV1503Z
PM: Jeremy Maute
Client PM: Peggy Kendall
Client PO: 1217608
Sample Containers
Lab ID: N15I041-01 Report Matrix: Water
Sample Type: Sample Received: 09/10/2015Sample: ABMW-04BR
Collected: 09/09/2015
Ship. Cont.pHP-LotPreservationLotSizeContainerDes
A Not
Provided
Cooler10mL EDTA (PP) Not Provided 4-5125mLBottle HDPE As-SP
Lab ID: N15I041-02 Report Matrix: Water
Sample Type: Sample Received: 09/10/2015Sample: ABMW-04 (9/9/15 14:37)
Collected: 09/09/2015
Ship. Cont.pHP-LotPreservationLotSizeContainerDes
A Not
Provided
Cooler10mL EDTA (PP) Not Provided 4-5125mLBottle HDPE As-SP
Lab ID: N15I041-03 Report Matrix: Water
Sample Type: Sample Received: 09/10/2015Sample: ABMW-04 (9/9/15 09:17)
Collected: 09/09/2015
Ship. Cont.pHP-LotPreservationLotSizeContainerDes
A Not
Provided
Cooler10mL EDTA (PP) Not Provided 4-5125mLBottle HDPE As-SP
Lab ID: N15I041-04 Report Matrix: Water
Sample Type: Sample Received: 09/10/2015Sample: ABMW-04D
Collected: 09/09/2015
Ship. Cont.pHP-LotPreservationLotSizeContainerDes
A Not
Provided
Cooler10mL EDTA (PP) Not Provided 4-5125mLBottle HDPE As-SP
Lab ID: N15I041-05 Report Matrix: Water
Sample Type: Sample Received: 09/10/2015Sample: MW-16D
Collected: 09/09/2015
Ship. Cont.pHP-LotPreservationLotSizeContainerDes
A Not
Provided
Cooler10mL EDTA (PP) Not Provided 4-5125mLBottle HDPE As-SP
Lab ID: N15I041-06 Report Matrix: Water
Sample Type: Sample Received: 09/10/2015Sample: MW-16D
Collected: 09/09/2015
Ship. Cont.pHP-LotLotSizeContainerDes
A Not
Provided
Cooler
Preservation
2.7mL CrVI Pres. (PP)Not Provided 9-9.5125mLBottle Cr-SP
18804 North Creek Parkway, Suite 100, Bothell, WA 98011 · P(206) 632-6206 · F(206) 632-6017 · brl@brooksapplied.com · www.brooksapplied.com
Page 24 of 37
Project ID: DUK-HV1503Z
PM: Jeremy Maute
Client PM: Peggy Kendall
Client PO: 1217608
Sample Containers
Lab ID: N15I041-07 Report Matrix: Water
Sample Type: Sample Received: 09/10/2015Sample: MW-16BR
Collected: 09/09/2015
Ship. Cont.pHP-LotPreservationLotSizeContainerDes
A Not
Provided
Cooler10mL EDTA (PP) Not Provided 4-5125mLBottle HDPE As-SP
Lab ID: N15I041-08 Report Matrix: Water
Sample Type: Sample Received: 09/10/2015Sample: MW-16BR
Collected: 09/09/2015
Ship. Cont.pHP-LotLotSizeContainerDes
A Not
Provided
Cooler
Preservation
2.7mL CrVI Pres. (PP)Not Provided 9-9.5125mLBottle Cr-SP
Lab ID: N15I041-09 Report Matrix: Water
Sample Type: Sample Received: 09/10/2015Sample: MW-16S
Collected: 09/09/2015
Ship. Cont.pHP-LotPreservationLotSizeContainerDes
A Not
Provided
Cooler10mL EDTA (PP) Not Provided 4-5125mLBottle HDPE As-SP
Lab ID: N15I041-10 Report Matrix: Water
Sample Type: Sample Received: 09/10/2015Sample: MW-16S
Collected: 09/09/2015
Ship. Cont.pHP-LotLotSizeContainerDes
A Not
Provided
Cooler
Preservation
2.7mL CrVI Pres. (PP)Not Provided 9-9.5125mLBottle Cr-SP
Lab ID: N15I041-11 Report Matrix: Water
Sample Type: Sample
Collected: 09/09/2015
Received: 09/10/2015Sample: MW-16D-DUP
Ship. Cont.pHP-LotPreservationLotSizeContainerDes
A Not
Provided
Cooler10mL EDTA (PP) Not Provided 4-5125mLBottle HDPE As-SP
Lab ID: N15I041-12 Report Matrix: Water
Sample Type: Sample
Collected: 09/09/2015
Received: 09/10/2015Sample: MW-16D-DUP
Ship. Cont.pHP-LotLotSizeContainerDes
A Not
Provided
Cooler
Preservation
2.7mL CrVI Pres. (PP)Not Provided 9-9.5125mLBottle Cr-SP
18804 North Creek Parkway, Suite 100, Bothell, WA 98011 · P(206) 632-6206 · F(206) 632-6017 · brl@brooksapplied.com · www.brooksapplied.com
Page 25 of 37
Project ID: DUK-HV1503Z
PM: Jeremy Maute
Client PM: Peggy Kendall
Client PO: 1217608
Shipping Containers
Cooler
Tracking No: 1Z094EW70131651013 via UPS
Temperature: -0.5 °C
Coolant Type: Ice
Description: Cooler
Damaged in transit? No
Returned to client? No
Custody seals present? No
Custody seals intact? No
COC present? Yes
Received: September 10, 2015 10:10
18804 North Creek Parkway, Suite 100, Bothell, WA 98011 · P(206) 632-6206 · F(206) 632-6017 · brl@brooksapplied.com · www.brooksapplied.com
Page 26 of 37
Page 27 of 37
Page 28 of 37
Page 29 of 37
Page 30 of 37
Page 31 of 37
Page 32 of 37
Page 33 of 37
Page 34 of 37
Page 35 of 37
Page 36 of 37
Page 37 of 37