HomeMy WebLinkAboutNC0038377_J15060206 Report_2017110113339 Hagers Ferry Road
Huntersville, NC 28078-7929
McGuire Nuclear Complex - MG03A2
Phone: 980-875-5245 Fax: 980-875-4349
Order Summary Report
Analytical Laboratory
Order Number: J15060206
Project Name:MAYO STEAM - AB GW ASSESSMENT SOIL
Lab Contact:Margaret Galvin-Karr
Date:7/6/2015
Customer Address:
Customer Name(s):Tim Hunsucker, Jerry Wylie, Kathy Webb, John Toepfer
Phone: 980-875-5219
Report Authorized By:
(Signature)
Program Comments:
Please contact the Program Manager (Margaret Galvin-Karr) with any questions regarding this report.
Data Flags & Calculations:
Any analytical tests or individual analytes within a test flagged with a Qualifier indicate a deviation from the method quality
system or quality control requirement. The qualifier description is found at the end of the Certificate of Analysis (sample results)
under the qualifiers heading. All results are reported on a dry weight basis unless otherwise noted. Subcontracted data
included on the Duke Certificate of Analysis is to be used as information only. Certified vendor results can be found in the
subcontracted lab final report. Duke Energy Analytical Laboratory subcontracts analyses to other vendor laboratories that have
been qualified by Duke Energy to perform these analyses except where noted.
Data Package:
This data package includes analytical results that are applicable only to the samples described in this narrative. An estimation of
the uncertainty of measurement for the results in the report is available upon request. This report shall not be reproduced, except
in full, without the written consent of the Analytical Laboratory. Please contact the Analytical laboratory with any questions. The
order of individual sections within this report is as follows:
Job Summary Report, Sample Identification, Technical Validation of Data Package, Analytical Laboratory Certificate of Analysis,
Analytical Laboratory QC Reports, Sub-contracted Laboratory Results, Customer Specific Data Sheets, Reports &
Documentation, Customer Database Entries, Test Case Narratives, Chain of Custody (COC)
Certification:
The Analytical Laboratory holds the following State Certifications : North Carolina (DENR) Certificate #248, South Carolina
(DHEC) Laboratory ID # 99005. Contact the Analytical Laboratory for definitive information about the certification status of
specific methods.
Margaret Galvin-Karr
1 of 64
Sample ID's & Descriptions:
Sample ID Plant/Station
Collection
Date and Time Collected By Sample Description
2015017618 MAYO STEAM 02-Jun-15 9:35 AM Erin Black ABMW-1-EB
2015017619 MAYO STEAM 02-Jun-15 10:01 AM Erin Black ABMW-1(1.0-1.5)
2015017620 MAYO STEAM 02-Jun-15 11:30 AM Erin Black ABMW-1(11.5-12.0)
2015017621 MAYO STEAM 02-Jun-15 11:20 AM Erin Black AVMW-1(13.0-13.5)
4 Total Samples
2 of 64
COC and .pdf report are in agreement with sample totals
and analyses (compliance programs and procedures).
All Results are less than the laboratory reporting limits.
All laboratory QA/QC requirements are acceptable.
Yes No
Technical Validation Review
Checklist:
Yes No
Yes No
Report Sections Included:
Job Summary Report Sub-contracted Laboratory Results
Sample Identification Customer Specific Data Sheets, Reports, & Documentation
Technical Validation of Data Package Customer Database Entries
Analytical Laboratory Certificate of Analysis
Analytical Laboratory QC Report
Chain of Custody
Reviewed By:Margaret Galvin-Karr Date:7/6/2015
Electronic Data Deliverable (EDD) Sent Separately
3 of 64
Certificate of Laboratory Analysis
This report shall not be reproduced, except in full.
Order # J15060206
2015017618
Collection Date: 02-Jun-15 9:35 AM
Site:ABMW-1-EB
Matrix: SOIL
Analyte Analysis Date/TimeMethodUnits Qualifiers RDLResult
Sample #:
AnalystDF
METALS ANALYSIS BY VENDOR LAB - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
4 of 64
Certificate of Laboratory Analysis
This report shall not be reproduced, except in full.
Order # J15060206
2015017619
Collection Date: 02-Jun-15 10:01 AM
Site:ABMW-1(1.0-1.5)
Matrix: SOIL
Analyte Analysis Date/TimeMethodUnits Qualifiers RDLResult
Sample #:
AnalystDF
PERCENT SOLIDS - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
DIONEX ANIONS BY VENDOR - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
METALS ANALYSIS BY VENDOR LAB - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
PH IN SOIL - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
SPLP LEACHATE - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
TOTAL ORGANIC CARBON IN SOILS - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
5 of 64
Certificate of Laboratory Analysis
This report shall not be reproduced, except in full.
Order # J15060206
2015017620
Collection Date: 02-Jun-15 11:30 AM
Site:ABMW-1(11.5-12.0)
Matrix: SOIL
Analyte Analysis Date/TimeMethodUnits Qualifiers RDLResult
Sample #:
AnalystDF
PERCENT SOLIDS - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
DIONEX ANIONS BY VENDOR - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
METALS ANALYSIS BY VENDOR LAB - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
PH IN SOIL - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
SPLP LEACHATE - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
TOTAL ORGANIC CARBON IN SOILS - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
6 of 64
Certificate of Laboratory Analysis
This report shall not be reproduced, except in full.
Order # J15060206
2015017621
Collection Date: 02-Jun-15 11:20 AM
Site:AVMW-1(13.0-13.5)
Matrix: SOIL
Analyte Analysis Date/TimeMethodUnits Qualifiers RDLResult
Sample #:
AnalystDF
PERCENT SOLIDS - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
DIONEX ANIONS BY VENDOR - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
METALS ANALYSIS BY VENDOR LAB - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
PH IN SOIL - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
TOTAL ORGANIC CARBON IN SOILS - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
7 of 64
#=CL#
July 06, 2015
LIMS USE: FR - PROGRAM MANAGER
LIMS OBJECT ID: 92253195
92253195
Project:
Pace Project No.:
RE:
Program Manager
Duke Energy
13339 Hagers Ferry Road
Bldg. 7405 MG30A2
Huntersville, NC 28078
J15060206
Dear Program Manager:
Enclosed are the analytical results for sample(s) received by the laboratory on June 05, 2015. The
results relate only to the samples included in this report. Results reported herein conform to the
most current TNI standards and the laboratory's Quality Assurance Manual, where applicable, unless
otherwise noted in the body of the report.
Analyses were performed at the Pace Analytical Services location indicated on the sample analyte
page for analysis unless otherwise footnoted.
If you have any questions concerning this report, please feel free to contact me.
Sincerely,
Kevin Herring
kevin.herring@pacelabs.com
HORIZON Database Administrator
Enclosures
cc:Marge Galvin-Karr, Duke Energy
Program Manager, Duke Energy
Mary Ann Ogle, Duke Energy
Rodney Wike, Duke Energy
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 1 of 56
8 of 64
#=CP#
CERTIFICATIONS
Pace Project No.:
Project:
92253195
J15060206
Minnesota Certification IDs
1700 Elm Street SE Suite 200, Minneapolis, MN 55414
A2LA Certification #: 2926.01
Alaska Certification #: UST-078
Alaska Certification #MN00064
Alabama Certification #40770
Arizona Certification #: AZ-0014
Arkansas Certification #: 88-0680
California Certification #: 01155CA
Colorado Certification #Pace
Connecticut Certification #: PH-0256
EPA Region 8 Certification #: 8TMS-L
Florida/NELAP Certification #: E87605
Guam Certification #:14-008r
Georgia Certification #: 959
Georgia EPD #: Pace
Idaho Certification #: MN00064
Hawaii Certification #MN00064
Illinois Certification #: 200011
Indiana Certification#C-MN-01
Iowa Certification #: 368
Kansas Certification #: E-10167
Kentucky Dept of Envi. Protection - DW #90062
Kentucky Dept of Envi. Protection - WW #:90062
Louisiana DEQ Certification #: 3086
Louisiana DHH #: LA140001
Maine Certification #: 2013011
Maryland Certification #: 322
Michigan DEPH Certification #: 9909
Minnesota Certification #: 027-053-137
Mississippi Certification #: Pace
Montana Certification #: MT0092
Nevada Certification #: MN_00064
Nebraska Certification #: Pace
New Jersey Certification #: MN-002
New York Certification #: 11647
North Carolina Certification #: 530
North Carolina State Public Health #: 27700
North Dakota Certification #: R-036
Ohio EPA #: 4150
Ohio VAP Certification #: CL101
Oklahoma Certification #: 9507
Oregon Certification #: MN200001
Oregon Certification #: MN300001
Pennsylvania Certification #: 68-00563
Puerto Rico Certification
Saipan (CNMI) #:MP0003
South Carolina #:74003001
Texas Certification #: T104704192
Tennessee Certification #: 02818
Utah Certification #: MN000642013-4
Virginia DGS Certification #: 251
Virginia/VELAP Certification #: Pace
Washington Certification #: C486
West Virginia Certification #: 382
West Virginia DHHR #:9952C
Wisconsin Certification #: 999407970
Ormond Beach Certification IDs
8 East Tower Circle, Ormond Beach, FL 32174
Alabama Certification #: 41320
Connecticut Certification #: PH-0216
Delaware Certification: FL NELAC Reciprocity
Florida Certification #: E83079
Georgia Certification #: 955
Guam Certification: FL NELAC Reciprocity
Hawaii Certification: FL NELAC Reciprocity
Illinois Certification #: 200068
Indiana Certification: FL NELAC Reciprocity
Kansas Certification #: E-10383
Kentucky Certification #: 90050
Louisiana Certification #: FL NELAC Reciprocity
Louisiana Environmental Certificate #: 05007
Maryland Certification: #346
Michigan Certification #: 9911
Mississippi Certification: FL NELAC Reciprocity
Missouri Certification #: 236
Montana Certification #: Cert 0074
Nebraska Certification: NE-OS-28-14
Nevada Certification: FL NELAC Reciprocity
New Hampshire Certification #: 2958
New York Certification #: 11608
North Carolina Environmental Certificate #: 667
North Carolina Certification #: 12710
Pennsylvania Certification #: 68-00547
Puerto Rico Certification #: FL01264
South Carolina Certification: #96042001
Tennessee Certification #: TN02974
Texas Certification: FL NELAC Reciprocity
US Virgin Islands Certification: FL NELAC Reciprocity
Virginia Environmental Certification #: 460165
West Virginia Certification #: 9962C
Wisconsin Certification #: 399079670
Wyoming (EPA Region 8): FL NELAC Reciprocity
Green Bay Certification IDs
1241 Bellevue Street, Green Bay, WI 54302
Florida/NELAP Certification #: E87948
Illinois Certification #: 200050
Kentucky Certification #: 82
Louisiana Certification #: 04168
Minnesota Certification #: 055-999-334
North Dakota Certification #: R-150
South Carolina Certification #: 83006001
Texas Certification #: T104704529-14-1
US Dept of Agriculture #: S-76505
Wisconsin Certification #: 405132750
Charlotte Certification IDs
9800 Kincey Ave. Ste 100, Huntersville, NC 28078
North Carolina Drinking Water Certification #: 37706
North Carolina Field Services Certification #: 5342
North Carolina Wastewater Certification #: 12
South Carolina Certification #: 99006001
Florida/NELAP Certification #: E87627
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 2 of 56
9 of 64
#=CP#
CERTIFICATIONS
Pace Project No.:
Project:
92253195
J15060206
Charlotte Certification IDs
Kentucky UST Certification #: 84
West Virginia Certification #: 357
Virginia/VELAP Certification #: 460221
Asheville Certification IDs
2225 Riverside Drive, Asheville, NC 28804
Florida/NELAP Certification #: E87648
Massachusetts Certification #: M-NC030
North Carolina Drinking Water Certification #: 37712
North Carolina Wastewater Certification #: 40
South Carolina Certification #: 99030001
West Virginia Certification #: 356
Virginia/VELAP Certification #: 460222
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 3 of 56
10 of 64
#=SS#
SAMPLE SUMMARY
Pace Project No.:
Project:
92253195
J15060206
Lab ID Sample ID Matrix Date Collected Date Received
92253195001 2015017618 Water 06/02/15 09:35 06/05/15 14:45
92253195002 2015017619 Solid 06/02/15 10:01 06/05/15 14:45
92253195003 2015017620 Solid 06/02/15 11:30 06/05/15 14:45
92253195004 2015017621 Solid 06/02/15 11:20 06/05/15 14:45
92253195005 2015017619 SPLP Water 06/02/15 10:01 06/05/15 14:45
92253195006 2015017620 SPLP Water 06/02/15 11:30 06/05/15 14:45
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 4 of 56
11 of 64
#=SA#
SAMPLE ANALYTE COUNT
Pace Project No.:
Project:
92253195
J15060206
Lab ID Sample ID Method
Analytes
Reported LaboratoryAnalysts
92253195001 2015017618 EPA 6020A 24 PASI-MTT3
EPA 7470A 1 PASI-MLMW
92253195002 2015017619 EPA 6010 16 PASI-OTAP
EPA 6020 8 PASI-OCRT
EPA 7471 1 PASI-OTAP
ASTM D2974-87 1 PASI-CSLJ
EPA 9045 1 PASI-AMLS
EPA 300.0 1 PASI-AAES2
EPA 353.2 1 PASI-ADMN
SM 4500-Cl-E 1 PASI-ASER
EPA 9056 2 PASI-OAIS
EPA 9056 1 PASI-OAIS
EPA 9060 Modified 4 PASI-GTJJ
92253195003 2015017620 EPA 6010 16 PASI-OTAP
EPA 6020 8 PASI-OCRT
EPA 7471 1 PASI-OTAP
ASTM D2974-87 1 PASI-CSLJ
EPA 9045 1 PASI-AMLS
EPA 300.0 1 PASI-AAES2
EPA 353.2 1 PASI-ADMN
SM 4500-Cl-E 1 PASI-ASER
EPA 9056 2 PASI-OAIS
EPA 9056 1 PASI-OAIS
EPA 9060 Modified 4 PASI-GTJJ
92253195004 2015017621 EPA 6010 16 PASI-OTAP
EPA 6020 8 PASI-OCRT
EPA 7471 1 PASI-OTAP
ASTM D2974-87 1 PASI-CSLJ
EPA 9045 1 PASI-AMLS
EPA 9056 2 PASI-OAIS
EPA 9056 1 PASI-OAIS
EPA 9060 Modified 4 PASI-GTJJ
92253195005 2015017619 SPLP EPA 6020A 24 PASI-MRJS
EPA 7470A 1 PASI-MLMW
92253195006 2015017620 SPLP EPA 6020A 24 PASI-MRJS
EPA 7470A 1 PASI-MLMW
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 5 of 56
12 of 64
#=HO#
SUMMARY OF DETECTION
Pace Project No.:
Project:
92253195
J15060206
Parameters AnalyzedResult
Lab Sample ID
Report Limit QualifiersUnitsMethod
Client Sample ID
92253195001 2015017618
Aluminum 13.9 ug/L 06/10/15 16:5610.0EPA 6020A
Barium 0.22J ug/L 06/10/15 16:560.30EPA 6020A
Cadmium 0.031J ug/L 06/10/15 16:560.080EPA 6020A
Calcium 70.1 ug/L 06/10/15 16:5640.0EPA 6020A
Chromium 0.26J ug/L 06/10/15 16:560.50EPA 6020A
Copper 0.77J ug/L 06/10/15 16:561.0EPA 6020A
Iron 22.2J ug/L 06/10/15 16:5650.0EPA 6020A
Lead 0.095J ug/L 06/10/15 16:560.10EPA 6020A
Magnesium 7.5J ug/L 06/10/15 16:5610.0EPA 6020A
Manganese 0.34J ug/L 06/10/15 16:560.50EPA 6020A
Potassium 16.1J ug/L 06/11/15 07:5450.0EPA 6020A
Sodium 45.5J ug/L 06/10/15 16:5650.0EPA 6020A
Strontium 0.17J ug/L 06/10/15 16:560.50EPA 6020A
Zinc 5.5 ug/L 06/10/15 16:565.0EPA 6020A
92253195002 2015017619
Aluminum 6960 mg/kg 06/15/15 01:2343.3EPA 6010
Barium 150 mg/kg 06/15/15 01:234.3EPA 6010
Beryllium 2.1 mg/kg 06/15/15 01:230.43EPA 6010
Boron 27.4 mg/kg 06/15/15 01:2321.7EPA 6010
Calcium 2070 mg/kg 06/15/15 01:23217EPA 6010
Chromium 25.0 mg/kg 06/15/15 01:232.2EPA 6010
Copper 37.9 mg/kg 06/15/15 01:232.2EPA 6010
Iron 2240 mg/kg 06/15/15 01:2317.3EPA 6010
Magnesium 561 mg/kg 06/15/15 01:23217EPA 6010
Manganese 18.4 mg/kg 06/15/15 01:232.2EPA 6010
Nickel 14.3 mg/kg 06/15/15 01:232.2EPA 6010
Potassium 1010 mg/kg 06/15/15 01:23433EPA 6010
Strontium 71.8 mg/kg 06/15/15 01:234.3EPA 6010
Zinc 18.8 mg/kg 06/15/15 01:238.7EPA 6010
Arsenic 16.6 mg/kg 06/13/15 16:208.7EPA 6020
Cobalt 7.6J mg/kg 06/13/15 16:208.7EPA 6020
Lead 13.0 mg/kg 06/13/15 16:208.7EPA 6020
Vanadium 39.3 mg/kg 06/13/15 16:208.7EPA 6020
Percent Moisture 40.8 %07/06/15 09:450.10ASTM D2974-87
pH at 25 Degrees C 10.4 Std. Units 06/14/15 15:000.10EPA 9045
Sulfate 19.9 mg/L 06/16/15 17:22 B3.4EPA 300.0
RPD%17.2 %06/27/15 17:220.10EPA 9060 Modified
Total Organic Carbon 77800 mg/kg 06/27/15 17:225940EPA 9060 Modified
Total Organic Carbon 92400 mg/kg 06/27/15 17:286070EPA 9060 Modified
Mean Total Organic Carbon 85100 mg/kg 06/27/15 17:226000EPA 9060 Modified
92253195003 2015017620
Aluminum 7960 mg/kg 06/15/15 01:3939.2EPA 6010
Barium 152 mg/kg 06/15/15 01:393.9EPA 6010
Beryllium 1.9 mg/kg 06/15/15 01:390.39EPA 6010
Boron 27.4 mg/kg 06/15/15 01:3919.6EPA 6010
Calcium 2260 mg/kg 06/15/15 01:39196EPA 6010
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 6 of 56
13 of 64
#=HO#
SUMMARY OF DETECTION
Pace Project No.:
Project:
92253195
J15060206
Parameters AnalyzedResult
Lab Sample ID
Report Limit QualifiersUnitsMethod
Client Sample ID
92253195003 2015017620
Chromium 26.9 mg/kg 06/15/15 01:392.0EPA 6010
Copper 34.6 mg/kg 06/15/15 01:392.0EPA 6010
Iron 2710 mg/kg 06/15/15 01:3915.7EPA 6010
Magnesium 712 mg/kg 06/15/15 01:39196EPA 6010
Manganese 31.3 mg/kg 06/15/15 01:392.0EPA 6010
Nickel 14.6 mg/kg 06/15/15 01:392.0EPA 6010
Potassium 1100 mg/kg 06/15/15 01:39392EPA 6010
Strontium 111 mg/kg 06/15/15 01:393.9EPA 6010
Zinc 21.9 mg/kg 06/15/15 01:397.8EPA 6010
Arsenic 26.2 mg/kg 06/13/15 16:257.8EPA 6020
Cobalt 8.3 mg/kg 06/13/15 16:257.8EPA 6020
Lead 13.5 mg/kg 06/13/15 16:257.8EPA 6020
Vanadium 46.2 mg/kg 06/13/15 16:257.8EPA 6020
Percent Moisture 34.7 %07/06/15 09:450.10ASTM D2974-87
pH at 25 Degrees C 8.2 Std. Units 06/14/15 15:000.10EPA 9045
Sulfate 4.1 mg/L 06/16/15 18:03 B3.1EPA 300.0
RPD%10.2 %06/27/15 17:580.10EPA 9060 Modified
Total Organic Carbon 46700 mg/kg 06/27/15 17:583680EPA 9060 Modified
Total Organic Carbon 51700 mg/kg 06/27/15 18:053700EPA 9060 Modified
Mean Total Organic Carbon 49200 mg/kg 06/27/15 17:583690EPA 9060 Modified
92253195004 2015017621
Aluminum 7090 mg/kg 06/15/15 01:4430.9EPA 6010
Barium 53.8 mg/kg 06/15/15 01:443.1EPA 6010
Beryllium 0.23J mg/kg 06/15/15 01:440.31EPA 6010
Calcium 410 mg/kg 06/15/15 01:44155EPA 6010
Chromium 3.7 mg/kg 06/15/15 01:441.5EPA 6010
Copper 4.1 mg/kg 06/15/15 01:441.5EPA 6010
Iron 8770 mg/kg 06/15/15 01:4412.4EPA 6010
Magnesium 1190 mg/kg 06/15/15 01:44155EPA 6010
Manganese 92.2 mg/kg 06/15/15 01:441.5EPA 6010
Nickel 1.4J mg/kg 06/15/15 01:441.5EPA 6010
Potassium 1350 mg/kg 06/15/15 01:44309EPA 6010
Strontium 10.8 mg/kg 06/15/15 01:443.1EPA 6010
Zinc 12.7 mg/kg 06/15/15 01:446.2EPA 6010
Vanadium 11.9 mg/kg 06/13/15 16:286.2EPA 6020
Mercury 0.011 mg/kg 06/16/15 12:420.010EPA 7471
Percent Moisture 19.7 %07/06/15 09:450.10ASTM D2974-87
pH at 25 Degrees C 4.9 Std. Units 06/14/15 15:000.10EPA 9045
RPD%27.8 %06/28/15 08:560.10EPA 9060 Modified
Total Organic Carbon 6520 mg/kg 06/28/15 08:56744EPA 9060 Modified
Total Organic Carbon 4930 mg/kg 06/28/15 09:03751EPA 9060 Modified
Mean Total Organic Carbon 5730 mg/kg 06/28/15 08:56747EPA 9060 Modified
92253195005 2015017619 SPLP
Aluminum 234 ug/L 07/01/15 01:1010.0EPA 6020A
Antimony 2.0 ug/L 07/01/15 01:100.50EPA 6020A
Arsenic 39.6 ug/L 07/01/15 01:100.50EPA 6020A
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 7 of 56
14 of 64
#=HO#
SUMMARY OF DETECTION
Pace Project No.:
Project:
92253195
J15060206
Parameters AnalyzedResult
Lab Sample ID
Report Limit QualifiersUnitsMethod
Client Sample ID
92253195005 2015017619 SPLP
Barium 37.1 ug/L 07/01/15 01:100.30EPA 6020A
Boron 659 ug/L 07/02/15 08:4225.0EPA 6020A
Calcium 23100 ug/L 07/02/15 08:42200EPA 6020A
Chromium 18.3 ug/L 07/01/15 01:100.50EPA 6020A
Copper 0.65J ug/L 07/01/15 01:101.0EPA 6020A
Iron 24.3J ug/L 07/01/15 01:1050.0EPA 6020A
Lead 0.16 ug/L 07/01/15 01:100.10EPA 6020A
Magnesium 58.0 ug/L 07/01/15 01:1010.0EPA 6020A
Manganese 2.6 ug/L 07/01/15 01:100.50EPA 6020A
Molybdenum 8.0 ug/L 07/01/15 01:100.50EPA 6020A
Nickel 0.26J ug/L 07/01/15 01:100.50EPA 6020A
Potassium 98.8 ug/L 07/01/15 01:1050.0EPA 6020A
Selenium 0.55 ug/L 07/01/15 01:100.50EPA 6020A
Sodium 1180 ug/L 07/01/15 01:1050.0EPA 6020A
Strontium 150 ug/L 07/01/15 01:100.50EPA 6020A
Vanadium 120 ug/L 07/01/15 01:101.0EPA 6020A
Zinc 6.0 ug/L 07/01/15 01:105.0EPA 6020A
92253195006 2015017620 SPLP
Aluminum 921 ug/L 07/01/15 01:1410.0EPA 6020A
Antimony 4.6 ug/L 07/01/15 01:140.50EPA 6020A
Arsenic 143 ug/L 07/01/15 01:140.50EPA 6020A
Barium 149 ug/L 07/01/15 01:140.30EPA 6020A
Beryllium 0.45 ug/L 07/01/15 01:140.20EPA 6020A
Boron 155 ug/L 07/01/15 01:145.0EPA 6020A
Cadmium 0.074J ug/L 07/01/15 01:140.080EPA 6020A
Calcium 6460 ug/L 07/01/15 01:1440.0EPA 6020A
Chromium 15.7 ug/L 07/01/15 01:140.50EPA 6020A
Cobalt 0.83 ug/L 07/01/15 01:140.50EPA 6020A
Copper 10.8 ug/L 07/01/15 01:141.0EPA 6020A
Iron 302 ug/L 07/01/15 01:1450.0EPA 6020A
Lead 1.9 ug/L 07/01/15 01:140.10EPA 6020A
Magnesium 1580 ug/L 07/01/15 01:1410.0EPA 6020A
Manganese 8.1 ug/L 07/01/15 01:140.50EPA 6020A
Molybdenum 4.4 ug/L 07/01/15 01:140.50EPA 6020A
Nickel 2.6 ug/L 07/01/15 01:140.50EPA 6020A
Potassium 304 ug/L 07/01/15 01:1450.0EPA 6020A
Selenium 0.96 ug/L 07/01/15 01:140.50EPA 6020A
Sodium 1620 ug/L 07/01/15 01:1450.0EPA 6020A
Strontium 192 ug/L 07/01/15 01:140.50EPA 6020A
Thallium 0.31 ug/L 07/01/15 01:140.10EPA 6020A
Vanadium 107 ug/L 07/01/15 01:141.0EPA 6020A
Zinc 10.6 ug/L 07/01/15 01:145.0EPA 6020A
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 8 of 56
15 of 64
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92253195
J15060206
Method:
Client:Duke Energy
EPA 6010
Date:July 06, 2015
Description:6010 MET ICP
General Information:
3 samples were analyzed for EPA 6010. All samples were received in acceptable condition with any exceptions noted below or on the
chain-of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Sample Preparation:
The samples were prepared in accordance with EPA 3050 with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
QC Batch: MPRP/24673
A matrix spike and/or matrix spike duplicate (MS/MSD) were performed on the following sample(s): 92253145025
M1: Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.
• MS (Lab ID: 1240561)
• Aluminum
• Barium
• Beryllium
• Calcium
• Iron
• Magnesium
• Manganese
• Molybdenum
• Nickel
• Potassium
• Strontium
• Zinc
• MSD (Lab ID: 1240563)
• Aluminum
• Barium
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 9 of 56
16 of 64
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92253195
J15060206
Method:
Client:Duke Energy
EPA 6010
Date:July 06, 2015
Description:6010 MET ICP
QC Batch: MPRP/24673
A matrix spike and/or matrix spike duplicate (MS/MSD) were performed on the following sample(s): 92253145025
M1: Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.
• Beryllium
• Calcium
• Iron
• Magnesium
• Manganese
• Molybdenum
• Nickel
• Potassium
• Strontium
• Zinc
Additional Comments:
Batch Comments:
Sample was diluted due to the presence of high levels of non-target analytes or other matrix interference.
• QC Batch: ICP / 15063
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 10 of 56
17 of 64
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92253195
J15060206
Method:
Client:Duke Energy
EPA 6020
Date:July 06, 2015
Description:6020 MET ICPMS
General Information:
3 samples were analyzed for EPA 6020. All samples were received in acceptable condition with any exceptions noted below or on the
chain-of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Sample Preparation:
The samples were prepared in accordance with EPA 3050 with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Internal Standards:
All internal standards were within QC limits with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
QC Batch: MPRP/24674
A matrix spike and/or matrix spike duplicate (MS/MSD) were performed on the following sample(s): 92253145025
M6: Matrix spike and Matrix spike duplicate recovery not evaluated against control limits due to sample dilution.
• MS (Lab ID: 1240566)
• Antimony
• Cadmium
• Cobalt
• Selenium
• Vanadium
• MSD (Lab ID: 1240567)
• Antimony
• Cadmium
• Cobalt
• Lead
• Selenium
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 11 of 56
18 of 64
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92253195
J15060206
Method:
Client:Duke Energy
EPA 6020
Date:July 06, 2015
Description:6020 MET ICPMS
Additional Comments:
Batch Comments:
Sample was diluted due to the presence of high levels of non-target analytes or other matrix interference.
• QC Batch: ICPM / 10002
Analyte Comments:
QC Batch: MPRP/24674
N2: The lab does not hold TNI accreditation for this parameter.
• 2015017619 (Lab ID: 92253195002)
• Antimony
• 2015017620 (Lab ID: 92253195003)
• Antimony
• 2015017621 (Lab ID: 92253195004)
• Antimony
• BLANK (Lab ID: 1240564)
• Antimony
• LCS (Lab ID: 1240565)
• Antimony
• MS (Lab ID: 1240566)
• Antimony
• MSD (Lab ID: 1240567)
• Antimony
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 12 of 56
19 of 64
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92253195
J15060206
Method:
Client:Duke Energy
EPA 6020A
Date:July 06, 2015
Description:6020A MET ICPMS
General Information:
3 samples were analyzed for EPA 6020A. All samples were received in acceptable condition with any exceptions noted below or on the
chain-of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Sample Preparation:
The samples were prepared in accordance with EPA 3020 with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Internal Standards:
All internal standards were within QC limits with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
QC Batch: MPRP/55069
A matrix spike and/or matrix spike duplicate (MS/MSD) were performed on the following sample(s): 92253161011
M1: Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.
• MS (Lab ID: 1989762)
• Aluminum
• MSD (Lab ID: 1989763)
• Aluminum
Additional Comments:
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 13 of 56
20 of 64
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92253195
J15060206
Method:
Client:Duke Energy
EPA 7470A
Date:July 06, 2015
Description:7470A Mercury
General Information:
3 samples were analyzed for EPA 7470A. All samples were received in acceptable condition with any exceptions noted below or on the
chain-of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Sample Preparation:
The samples were prepared in accordance with EPA 7470A with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Additional Comments:
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 14 of 56
21 of 64
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92253195
J15060206
Method:
Client:Duke Energy
EPA 7471
Date:July 06, 2015
Description:7471 Mercury
General Information:
3 samples were analyzed for EPA 7471. All samples were received in acceptable condition with any exceptions noted below or on the
chain-of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Sample Preparation:
The samples were prepared in accordance with EPA 7471 with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Additional Comments:
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 15 of 56
22 of 64
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92253195
J15060206
Method:
Client:Duke Energy
EPA 9045
Date:July 06, 2015
Description:9045 pH Soil
General Information:
3 samples were analyzed for EPA 9045. All samples were received in acceptable condition with any exceptions noted below or on the
chain-of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Duplicate Sample:
All duplicate sample results were within method acceptance criteria with any exceptions noted below.
QC Batch: WET/38033
D6: The relative percent difference (RPD) between the sample and sample duplicate exceeded laboratory control limits.
• DUP (Lab ID: 1481715)
• pH at 25 Degrees C
• DUP (Lab ID: 1481716)
• pH at 25 Degrees C
Additional Comments:
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 16 of 56
23 of 64
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92253195
J15060206
Method:
Client:Duke Energy
EPA 300.0
Date:July 06, 2015
Description:300.0 IC Anions, SPLP
General Information:
2 samples were analyzed for EPA 300.0. All samples were received in acceptable condition with any exceptions noted below or on the
chain-of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
QC Batch: WETA/23324
B: Analyte was detected in the associated method blank.
• BLANK for HBN 268289 [WETA/233 (Lab ID: 1485896)
• Sulfate
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Additional Comments:
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 17 of 56
24 of 64
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92253195
J15060206
Method:
Client:Duke Energy
EPA 353.2
Date:July 06, 2015
Description:353.2 Nitrogen, NO2/NO3, SPLP
General Information:
2 samples were analyzed for EPA 353.2. All samples were received in acceptable condition with any exceptions noted below or on the
chain-of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
H1: Analysis conducted outside the EPA method holding time.
• 2015017619 (Lab ID: 92253195002)
• 2015017620 (Lab ID: 92253195003)
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Additional Comments:
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 18 of 56
25 of 64
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92253195
J15060206
Method:
Client:Duke Energy
SM 4500-Cl-E
Date:July 06, 2015
Description:4500 Chloride, SPLP
General Information:
2 samples were analyzed for SM 4500-Cl-E. All samples were received in acceptable condition with any exceptions noted below or on
the chain-of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
QC Batch: WETA/23354
A matrix spike and/or matrix spike duplicate (MS/MSD) were performed on the following sample(s): 92252532003
M1: Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.
• MS (Lab ID: 1487999)
• Chloride
• MSD (Lab ID: 1488000)
• Chloride
Additional Comments:
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 19 of 56
26 of 64
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92253195
J15060206
Method:
Client:Duke Energy
EPA 9056
Date:July 06, 2015
Description:9056 IC Anions
General Information:
3 samples were analyzed for EPA 9056. All samples were received in acceptable condition with any exceptions noted below or on the
chain-of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Additional Comments:
Analyte Comments:
QC Batch: WETA/47190
D3: Sample was diluted due to the presence of high levels of non-target analytes or other matrix interference.
• 2015017619 (Lab ID: 92253195002)
• Chloride
• Sulfate
• 2015017620 (Lab ID: 92253195003)
• Chloride
• Sulfate
• 2015017621 (Lab ID: 92253195004)
• Chloride
• Sulfate
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 20 of 56
27 of 64
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92253195
J15060206
Method:
Client:Duke Energy
EPA 9056
Date:July 06, 2015
Description:9056 IC Anions 48hr
General Information:
3 samples were analyzed for EPA 9056. All samples were received in acceptable condition with any exceptions noted below or on the
chain-of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
H3: Sample was received or analysis requested beyond the recognized method holding time.
• 2015017619 (Lab ID: 92253195002)
• 2015017620 (Lab ID: 92253195003)
• 2015017621 (Lab ID: 92253195004)
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Additional Comments:
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 21 of 56
28 of 64
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92253195
J15060206
Method:
Client:Duke Energy
EPA 9060 Modified
Date:July 06, 2015
Description:Total Organic Carbon
General Information:
3 samples were analyzed for EPA 9060 Modified. All samples were received in acceptable condition with any exceptions noted below
or on the chain-of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Additional Comments:
This data package has been reviewed for quality and completeness and is approved for release.
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 22 of 56
29 of 64
#=AR#
ANALYTICAL RESULTS
Pace Project No.:
Project:
92253195
J15060206
Sample:2015017618 Lab ID:92253195001 Collected:06/02/15 09:35 Received:06/05/15 14:45 Matrix:Water
Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit
Report
Analytical Method: EPA 6020A Preparation Method: EPA 30206020A MET ICPMS
Aluminum 13.9 ug/L 06/10/15 16:56 7429-90-506/10/15 09:2410.0 3.0 1
Antimony ND ug/L 06/10/15 16:56 7440-36-006/10/15 09:240.50 0.15 1
Arsenic ND ug/L 06/10/15 16:56 7440-38-206/10/15 09:240.50 0.11 1
Barium 0.22J ug/L 06/10/15 16:56 7440-39-306/10/15 09:240.30 0.081 1
Beryllium ND ug/L 06/10/15 16:56 7440-41-706/10/15 09:240.20 0.067 1
Boron ND ug/L 06/10/15 16:56 7440-42-806/10/15 09:245.0 1.1 1
Cadmium 0.031J ug/L 06/10/15 16:56 7440-43-906/10/15 09:240.080 0.024 1
Calcium 70.1 ug/L 06/10/15 16:56 7440-70-206/10/15 09:2440.0 16.0 1
Chromium 0.26J ug/L 06/10/15 16:56 7440-47-306/10/15 09:240.50 0.17 1
Cobalt ND ug/L 06/10/15 16:56 7440-48-406/10/15 09:240.50 0.13 1
Copper 0.77J ug/L 06/10/15 16:56 7440-50-806/10/15 09:241.0 0.21 1
Iron 22.2J ug/L 06/10/15 16:56 7439-89-606/10/15 09:2450.0 13.7 1
Lead 0.095J ug/L 06/10/15 16:56 7439-92-106/10/15 09:240.10 0.046 1
Magnesium 7.5J ug/L 06/10/15 16:56 7439-95-406/10/15 09:2410.0 3.2 1
Manganese 0.34J ug/L 06/10/15 16:56 7439-96-506/10/15 09:240.50 0.24 1
Molybdenum ND ug/L 06/10/15 16:56 7439-98-706/10/15 09:240.50 0.094 1
Nickel ND ug/L 06/10/15 16:56 7440-02-006/10/15 09:240.50 0.16 1
Potassium 16.1J ug/L 06/11/15 07:54 7440-09-706/10/15 09:2450.0 11.7 1
Selenium ND ug/L 06/10/15 16:56 7782-49-206/10/15 09:240.50 0.20 1
Sodium 45.5J ug/L 06/10/15 16:56 7440-23-506/10/15 09:2450.0 16.3 1
Strontium 0.17J ug/L 06/10/15 16:56 7440-24-606/10/15 09:240.50 0.13 1
Thallium ND ug/L 06/10/15 16:56 7440-28-006/10/15 09:240.10 0.015 1
Vanadium ND ug/L 06/10/15 16:56 7440-62-206/10/15 09:241.0 0.28 1
Zinc 5.5 ug/L 06/10/15 16:56 7440-66-606/10/15 09:245.0 2.4 1
Analytical Method: EPA 7470A Preparation Method: EPA 7470A7470A Mercury
Mercury ND ug/L 06/10/15 14:31 7439-97-606/10/15 10:300.20 0.022 1
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 23 of 56
30 of 64
#=AR#
ANALYTICAL RESULTS
Pace Project No.:
Project:
92253195
J15060206
Sample:2015017619 Lab ID:92253195002 Collected:06/02/15 10:01 Received:06/05/15 14:45 Matrix:Solid
Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions.
Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit
Report
Analytical Method: EPA 6010 Preparation Method: EPA 30506010 MET ICP
Aluminum 6960 mg/kg 06/15/15 01:23 7429-90-506/12/15 16:1643.3 21.7 5
Barium 150 mg/kg 06/15/15 01:23 7440-39-306/12/15 16:164.3 2.2 5
Beryllium 2.1 mg/kg 06/15/15 01:23 7440-41-706/12/15 16:160.43 0.22 5
Boron 27.4 mg/kg 06/15/15 01:23 7440-42-806/12/15 16:1621.7 10.8 5
Calcium 2070 mg/kg 06/15/15 01:23 7440-70-206/12/15 16:162171085
Chromium 25.0 mg/kg 06/15/15 01:23 7440-47-306/12/15 16:162.2 1.1 5
Copper 37.9 mg/kg 06/15/15 01:23 7440-50-806/12/15 16:162.2 1.1 5
Iron 2240 mg/kg 06/15/15 01:23 7439-89-606/12/15 16:1617.3 8.7 5
Magnesium 561 mg/kg 06/15/15 01:23 7439-95-406/12/15 16:162171085
Manganese 18.4 mg/kg 06/15/15 01:23 7439-96-506/12/15 16:162.2 1.1 5
Molybdenum ND mg/kg 06/15/15 01:23 7439-98-706/12/15 16:164.3 2.2 5
Nickel 14.3 mg/kg 06/15/15 01:23 7440-02-006/12/15 16:162.2 1.1 5
Potassium 1010 mg/kg 06/15/15 01:23 7440-09-706/12/15 16:164332175
Sodium ND mg/kg 06/15/15 01:23 7440-23-506/12/15 16:164332175
Strontium 71.8 mg/kg 06/15/15 01:23 7440-24-606/12/15 16:164.3 2.2 5
Zinc 18.8 mg/kg 06/15/15 01:23 7440-66-606/12/15 16:168.7 4.3 5
Analytical Method: EPA 6020 Preparation Method: EPA 30506020 MET ICPMS
Antimony ND mg/kg 06/13/15 16:20 7440-36-0 N206/12/15 16:168.7 4.3 100
Arsenic 16.6 mg/kg 06/13/15 16:20 7440-38-206/12/15 16:168.7 4.3 100
Cadmium ND mg/kg 06/13/15 16:20 7440-43-906/12/15 16:161.0 0.52 100
Cobalt 7.6J mg/kg 06/13/15 16:20 7440-48-406/12/15 16:168.7 4.3 100
Lead 13.0 mg/kg 06/13/15 16:20 7439-92-106/12/15 16:168.7 4.3 100
Selenium ND mg/kg 06/13/15 16:20 7782-49-206/12/15 16:168.7 4.3 100
Thallium ND mg/kg 06/13/15 16:20 7440-28-006/12/15 16:168.7 4.3 100
Vanadium 39.3 mg/kg 06/13/15 16:20 7440-62-206/12/15 16:168.7 4.3 100
Analytical Method: EPA 7471 Preparation Method: EPA 74717471 Mercury
Mercury ND mg/kg 06/16/15 12:31 7439-97-606/12/15 16:300.014 0.0068 1
Analytical Method: ASTM D2974-87Percent Moisture
Percent Moisture 40.8 %07/06/15 09:450.10 0.10 1
Analytical Method: EPA 90459045 pH Soil
pH at 25 Degrees C 10.4 Std. Units 06/14/15 15:000.10 0.10 1
Analytical Method: EPA 300.0 Leachate Method/Date: EPA 1312; 06/08/15 00:00300.0 IC Anions, SPLP
Sulfate 19.9 mg/L 06/16/15 17:22 14808-79-8 B3.4 1.7 1
Analytical Method: EPA 353.2 Leachate Method/Date: EPA 1312; 06/08/15 00:00353.2 Nitrogen, NO2/NO3, SPLP
Nitrogen, Nitrate ND mg/L 06/18/15 17:17 H10.34 0.34 1
Analytical Method: SM 4500-Cl-E Leachate Method/Date: EPA 1312; 06/08/15 00:004500 Chloride, SPLP
Chloride ND mg/L 06/18/15 05:02 16887-00-68.4 4.2 1
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 24 of 56
31 of 64
#=AR#
ANALYTICAL RESULTS
Pace Project No.:
Project:
92253195
J15060206
Sample:2015017619 Lab ID:92253195002 Collected:06/02/15 10:01 Received:06/05/15 14:45 Matrix:Solid
Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions.
Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit
Report
Analytical Method: EPA 90569056 IC Anions
Chloride ND mg/kg 06/11/15 05:04 16887-00-6 D34252135
Sulfate ND mg/kg 06/11/15 05:04 14808-79-8 D34252135
Analytical Method: EPA 90569056 IC Anions 48hr
Nitrate as N ND mg/kg 06/11/15 05:04 14797-55-8 H342.5 21.3 5
Analytical Method: EPA 9060 ModifiedTotal Organic Carbon
Surrogates
RPD%17.2 %06/27/15 17:220.10 0.10 1
Total Organic Carbon 77800 mg/kg 06/27/15 17:22 7440-44-0594029701
Total Organic Carbon 92400 mg/kg 06/27/15 17:28 7440-44-0607030301
Mean Total Organic Carbon 85100 mg/kg 06/27/15 17:22 7440-44-0600030001
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 25 of 56
32 of 64
#=AR#
ANALYTICAL RESULTS
Pace Project No.:
Project:
92253195
J15060206
Sample:2015017620 Lab ID:92253195003 Collected:06/02/15 11:30 Received:06/05/15 14:45 Matrix:Solid
Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions.
Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit
Report
Analytical Method: EPA 6010 Preparation Method: EPA 30506010 MET ICP
Aluminum 7960 mg/kg 06/15/15 01:39 7429-90-506/12/15 16:1639.2 19.6 5
Barium 152 mg/kg 06/15/15 01:39 7440-39-306/12/15 16:163.9 2.0 5
Beryllium 1.9 mg/kg 06/15/15 01:39 7440-41-706/12/15 16:160.39 0.20 5
Boron 27.4 mg/kg 06/15/15 01:39 7440-42-806/12/15 16:1619.6 9.8 5
Calcium 2260 mg/kg 06/15/15 01:39 7440-70-206/12/15 16:1619698.1 5
Chromium 26.9 mg/kg 06/15/15 01:39 7440-47-306/12/15 16:162.0 0.98 5
Copper 34.6 mg/kg 06/15/15 01:39 7440-50-806/12/15 16:162.0 0.98 5
Iron 2710 mg/kg 06/15/15 01:39 7439-89-606/12/15 16:1615.7 7.8 5
Magnesium 712 mg/kg 06/15/15 01:39 7439-95-406/12/15 16:1619698.1 5
Manganese 31.3 mg/kg 06/15/15 01:39 7439-96-506/12/15 16:162.0 0.98 5
Molybdenum ND mg/kg 06/15/15 01:39 7439-98-706/12/15 16:163.9 2.0 5
Nickel 14.6 mg/kg 06/15/15 01:39 7440-02-006/12/15 16:162.0 0.98 5
Potassium 1100 mg/kg 06/15/15 01:39 7440-09-706/12/15 16:163921965
Sodium ND mg/kg 06/15/15 01:39 7440-23-506/12/15 16:163921965
Strontium 111 mg/kg 06/15/15 01:39 7440-24-606/12/15 16:163.9 2.0 5
Zinc 21.9 mg/kg 06/15/15 01:39 7440-66-606/12/15 16:167.8 3.9 5
Analytical Method: EPA 6020 Preparation Method: EPA 30506020 MET ICPMS
Antimony ND mg/kg 06/13/15 16:25 7440-36-0 N206/12/15 16:167.8 3.9 100
Arsenic 26.2 mg/kg 06/13/15 16:25 7440-38-206/12/15 16:167.8 3.9 100
Cadmium ND mg/kg 06/13/15 16:25 7440-43-906/12/15 16:160.94 0.47 100
Cobalt 8.3 mg/kg 06/13/15 16:25 7440-48-406/12/15 16:167.8 3.9 100
Lead 13.5 mg/kg 06/13/15 16:25 7439-92-106/12/15 16:167.8 3.9 100
Selenium ND mg/kg 06/13/15 16:25 7782-49-206/12/15 16:167.8 3.9 100
Thallium ND mg/kg 06/13/15 16:25 7440-28-006/12/15 16:167.8 3.9 100
Vanadium 46.2 mg/kg 06/13/15 16:25 7440-62-206/12/15 16:167.8 3.9 100
Analytical Method: EPA 7471 Preparation Method: EPA 74717471 Mercury
Mercury ND mg/kg 06/16/15 12:39 7439-97-606/12/15 16:300.013 0.0064 1
Analytical Method: ASTM D2974-87Percent Moisture
Percent Moisture 34.7 %07/06/15 09:450.10 0.10 1
Analytical Method: EPA 90459045 pH Soil
pH at 25 Degrees C 8.2 Std. Units 06/14/15 15:000.10 0.10 1
Analytical Method: EPA 300.0 Leachate Method/Date: EPA 1312; 06/08/15 00:00300.0 IC Anions, SPLP
Sulfate 4.1 mg/L 06/16/15 18:03 14808-79-8 B3.1 1.5 1
Analytical Method: EPA 353.2 Leachate Method/Date: EPA 1312; 06/08/15 00:00353.2 Nitrogen, NO2/NO3, SPLP
Nitrogen, Nitrate ND mg/L 06/18/15 17:18 H10.31 0.31 1
Analytical Method: SM 4500-Cl-E Leachate Method/Date: EPA 1312; 06/08/15 00:004500 Chloride, SPLP
Chloride ND mg/L 06/19/15 05:18 16887-00-67.7 3.8 1
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 26 of 56
33 of 64
#=AR#
ANALYTICAL RESULTS
Pace Project No.:
Project:
92253195
J15060206
Sample:2015017620 Lab ID:92253195003 Collected:06/02/15 11:30 Received:06/05/15 14:45 Matrix:Solid
Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions.
Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit
Report
Analytical Method: EPA 90569056 IC Anions
Chloride ND mg/kg 06/11/15 05:25 16887-00-6 D33811915
Sulfate ND mg/kg 06/11/15 05:25 14808-79-8 D33811915
Analytical Method: EPA 90569056 IC Anions 48hr
Nitrate as N ND mg/kg 06/11/15 05:25 14797-55-8 H338.1 19.1 5
Analytical Method: EPA 9060 ModifiedTotal Organic Carbon
Surrogates
RPD%10.2 %06/27/15 17:580.10 0.10 1
Total Organic Carbon 46700 mg/kg 06/27/15 17:58 7440-44-0368018401
Total Organic Carbon 51700 mg/kg 06/27/15 18:05 7440-44-0370018501
Mean Total Organic Carbon 49200 mg/kg 06/27/15 17:58 7440-44-0369018401
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 27 of 56
34 of 64
#=AR#
ANALYTICAL RESULTS
Pace Project No.:
Project:
92253195
J15060206
Sample:2015017621 Lab ID:92253195004 Collected:06/02/15 11:20 Received:06/05/15 14:45 Matrix:Solid
Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions.
Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit
Report
Analytical Method: EPA 6010 Preparation Method: EPA 30506010 MET ICP
Aluminum 7090 mg/kg 06/15/15 01:44 7429-90-506/12/15 16:1630.9 15.5 5
Barium 53.8 mg/kg 06/15/15 01:44 7440-39-306/12/15 16:163.1 1.5 5
Beryllium 0.23J mg/kg 06/15/15 01:44 7440-41-706/12/15 16:160.31 0.15 5
Boron ND mg/kg 06/15/15 01:44 7440-42-806/12/15 16:1615.5 7.7 5
Calcium 410 mg/kg 06/15/15 01:44 7440-70-206/12/15 16:1615577.4 5
Chromium 3.7 mg/kg 06/15/15 01:44 7440-47-306/12/15 16:161.5 0.77 5
Copper 4.1 mg/kg 06/15/15 01:44 7440-50-806/12/15 16:161.5 0.77 5
Iron 8770 mg/kg 06/15/15 01:44 7439-89-606/12/15 16:1612.4 6.2 5
Magnesium 1190 mg/kg 06/15/15 01:44 7439-95-406/12/15 16:1615577.4 5
Manganese 92.2 mg/kg 06/15/15 01:44 7439-96-506/12/15 16:161.5 0.77 5
Molybdenum ND mg/kg 06/15/15 01:44 7439-98-706/12/15 16:163.1 1.5 5
Nickel 1.4J mg/kg 06/15/15 01:44 7440-02-006/12/15 16:161.5 0.77 5
Potassium 1350 mg/kg 06/15/15 01:44 7440-09-706/12/15 16:163091555
Sodium ND mg/kg 06/15/15 01:44 7440-23-506/12/15 16:163091555
Strontium 10.8 mg/kg 06/15/15 01:44 7440-24-606/12/15 16:163.1 1.5 5
Zinc 12.7 mg/kg 06/15/15 01:44 7440-66-606/12/15 16:166.2 3.1 5
Analytical Method: EPA 6020 Preparation Method: EPA 30506020 MET ICPMS
Antimony ND mg/kg 06/13/15 16:28 7440-36-0 N206/12/15 16:166.2 3.1 100
Arsenic ND mg/kg 06/13/15 16:28 7440-38-206/12/15 16:166.2 3.1 100
Cadmium ND mg/kg 06/13/15 16:28 7440-43-906/12/15 16:160.74 0.37 100
Cobalt ND mg/kg 06/13/15 16:28 7440-48-406/12/15 16:166.2 3.1 100
Lead ND mg/kg 06/13/15 16:28 7439-92-106/12/15 16:166.2 3.1 100
Selenium ND mg/kg 06/13/15 16:28 7782-49-206/12/15 16:166.2 3.1 100
Thallium ND mg/kg 06/13/15 16:28 7440-28-006/12/15 16:166.2 3.1 100
Vanadium 11.9 mg/kg 06/13/15 16:28 7440-62-206/12/15 16:166.2 3.1 100
Analytical Method: EPA 7471 Preparation Method: EPA 74717471 Mercury
Mercury 0.011 mg/kg 06/16/15 12:42 7439-97-606/12/15 16:300.010 0.0050 1
Analytical Method: ASTM D2974-87Percent Moisture
Percent Moisture 19.7 %07/06/15 09:450.10 0.10 1
Analytical Method: EPA 90459045 pH Soil
pH at 25 Degrees C 4.9 Std. Units 06/14/15 15:000.10 0.10 1
Analytical Method: EPA 90569056 IC Anions
Chloride ND mg/kg 06/11/15 05:47 16887-00-6 D33161585
Sulfate ND mg/kg 06/11/15 05:47 14808-79-8 D33161585
Analytical Method: EPA 90569056 IC Anions 48hr
Nitrate as N ND mg/kg 06/11/15 05:47 14797-55-8 H331.6 15.8 5
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 28 of 56
35 of 64
#=AR#
ANALYTICAL RESULTS
Pace Project No.:
Project:
92253195
J15060206
Sample:2015017621 Lab ID:92253195004 Collected:06/02/15 11:20 Received:06/05/15 14:45 Matrix:Solid
Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions.
Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit
Report
Analytical Method: EPA 9060 ModifiedTotal Organic Carbon
Surrogates
RPD%27.8 %06/28/15 08:560.10 0.10 1
Total Organic Carbon 6520 mg/kg 06/28/15 08:56 7440-44-07443721
Total Organic Carbon 4930 mg/kg 06/28/15 09:03 7440-44-07513751
Mean Total Organic Carbon 5730 mg/kg 06/28/15 08:56 7440-44-07473741
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 29 of 56
36 of 64
#=AR#
ANALYTICAL RESULTS
Pace Project No.:
Project:
92253195
J15060206
Sample:2015017619 SPLP Lab ID:92253195005 Collected:06/02/15 10:01 Received:06/05/15 14:45 Matrix:Water
Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit
Report
Analytical Method: EPA 6020A Preparation Method: EPA 30206020A MET ICPMS
Aluminum 234 ug/L 07/01/15 01:10 7429-90-506/29/15 10:2110.0 3.0 1
Antimony 2.0 ug/L 07/01/15 01:10 7440-36-006/29/15 10:210.50 0.15 1
Arsenic 39.6 ug/L 07/01/15 01:10 7440-38-206/29/15 10:210.50 0.11 1
Barium 37.1 ug/L 07/01/15 01:10 7440-39-306/29/15 10:210.30 0.081 1
Beryllium ND ug/L 07/01/15 01:10 7440-41-706/29/15 10:210.20 0.067 1
Boron 659 ug/L 07/02/15 08:42 7440-42-806/29/15 10:2125.0 5.6 5
Cadmium ND ug/L 07/01/15 01:10 7440-43-906/29/15 10:210.080 0.024 1
Calcium 23100 ug/L 07/02/15 08:42 7440-70-206/29/15 10:2120080.0 5
Chromium 18.3 ug/L 07/01/15 01:10 7440-47-306/29/15 10:210.50 0.17 1
Cobalt ND ug/L 07/01/15 01:10 7440-48-406/29/15 10:210.50 0.13 1
Copper 0.65J ug/L 07/01/15 01:10 7440-50-806/29/15 10:211.0 0.21 1
Iron 24.3J ug/L 07/01/15 01:10 7439-89-606/29/15 10:2150.0 13.7 1
Lead 0.16 ug/L 07/01/15 01:10 7439-92-106/29/15 10:210.10 0.046 1
Magnesium 58.0 ug/L 07/01/15 01:10 7439-95-406/29/15 10:2110.0 3.2 1
Manganese 2.6 ug/L 07/01/15 01:10 7439-96-506/29/15 10:210.50 0.24 1
Molybdenum 8.0 ug/L 07/01/15 01:10 7439-98-706/29/15 10:210.50 0.094 1
Nickel 0.26J ug/L 07/01/15 01:10 7440-02-006/29/15 10:210.50 0.16 1
Potassium 98.8 ug/L 07/01/15 01:10 7440-09-706/29/15 10:2150.0 11.7 1
Selenium 0.55 ug/L 07/01/15 01:10 7782-49-206/29/15 10:210.50 0.20 1
Sodium 1180 ug/L 07/01/15 01:10 7440-23-506/29/15 10:2150.0 16.3 1
Strontium 150 ug/L 07/01/15 01:10 7440-24-606/29/15 10:210.50 0.13 1
Thallium ND ug/L 07/01/15 01:10 7440-28-006/29/15 10:210.10 0.015 1
Vanadium 120 ug/L 07/01/15 01:10 7440-62-206/29/15 10:211.0 0.28 1
Zinc 6.0 ug/L 07/01/15 01:10 7440-66-606/29/15 10:215.0 2.4 1
Analytical Method: EPA 7470A Preparation Method: EPA 7470A7470A Mercury
Mercury ND ug/L 07/01/15 18:03 7439-97-606/29/15 14:300.20 0.022 1
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 30 of 56
37 of 64
#=AR#
ANALYTICAL RESULTS
Pace Project No.:
Project:
92253195
J15060206
Sample:2015017620 SPLP Lab ID:92253195006 Collected:06/02/15 11:30 Received:06/05/15 14:45 Matrix:Water
Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit
Report
Analytical Method: EPA 6020A Preparation Method: EPA 30206020A MET ICPMS
Aluminum 921 ug/L 07/01/15 01:14 7429-90-506/29/15 10:2110.0 3.0 1
Antimony 4.6 ug/L 07/01/15 01:14 7440-36-006/29/15 10:210.50 0.15 1
Arsenic 143 ug/L 07/01/15 01:14 7440-38-206/29/15 10:210.50 0.11 1
Barium 149 ug/L 07/01/15 01:14 7440-39-306/29/15 10:210.30 0.081 1
Beryllium 0.45 ug/L 07/01/15 01:14 7440-41-706/29/15 10:210.20 0.067 1
Boron 155 ug/L 07/01/15 01:14 7440-42-806/29/15 10:215.0 1.1 1
Cadmium 0.074J ug/L 07/01/15 01:14 7440-43-906/29/15 10:210.080 0.024 1
Calcium 6460 ug/L 07/01/15 01:14 7440-70-206/29/15 10:2140.0 16.0 1
Chromium 15.7 ug/L 07/01/15 01:14 7440-47-306/29/15 10:210.50 0.17 1
Cobalt 0.83 ug/L 07/01/15 01:14 7440-48-406/29/15 10:210.50 0.13 1
Copper 10.8 ug/L 07/01/15 01:14 7440-50-806/29/15 10:211.0 0.21 1
Iron 302 ug/L 07/01/15 01:14 7439-89-606/29/15 10:2150.0 13.7 1
Lead 1.9 ug/L 07/01/15 01:14 7439-92-106/29/15 10:210.10 0.046 1
Magnesium 1580 ug/L 07/01/15 01:14 7439-95-406/29/15 10:2110.0 3.2 1
Manganese 8.1 ug/L 07/01/15 01:14 7439-96-506/29/15 10:210.50 0.24 1
Molybdenum 4.4 ug/L 07/01/15 01:14 7439-98-706/29/15 10:210.50 0.094 1
Nickel 2.6 ug/L 07/01/15 01:14 7440-02-006/29/15 10:210.50 0.16 1
Potassium 304 ug/L 07/01/15 01:14 7440-09-706/29/15 10:2150.0 11.7 1
Selenium 0.96 ug/L 07/01/15 01:14 7782-49-206/29/15 10:210.50 0.20 1
Sodium 1620 ug/L 07/01/15 01:14 7440-23-506/29/15 10:2150.0 16.3 1
Strontium 192 ug/L 07/01/15 01:14 7440-24-606/29/15 10:210.50 0.13 1
Thallium 0.31 ug/L 07/01/15 01:14 7440-28-006/29/15 10:210.10 0.015 1
Vanadium 107 ug/L 07/01/15 01:14 7440-62-206/29/15 10:211.0 0.28 1
Zinc 10.6 ug/L 07/01/15 01:14 7440-66-606/29/15 10:215.0 2.4 1
Analytical Method: EPA 7470A Preparation Method: EPA 7470A7470A Mercury
Mercury ND ug/L 07/01/15 18:06 7439-97-606/29/15 14:300.20 0.022 1
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 31 of 56
38 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
MERP/13814
EPA 7470A
EPA 7470A
7470A Mercury Water
Associated Lab Samples:92253195001
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1989756
Associated Lab Samples:92253195001
Matrix:Water
Analyzed
Mercury ug/L ND 0.20 06/10/15 14:06
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1989757LABORATORY CONTROL SAMPLE:
LCSSpike
Mercury ug/L 5.05 100 80-120
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1989758MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92253195001
1989759
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Mercury ug/L 5 110 80-120106 4 205ND5.5 5.3
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 32 of 56
39 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
MERP/14018
EPA 7470A
EPA 7470A
7470A Mercury Water
Associated Lab Samples:92253195005, 92253195006
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:2006739
Associated Lab Samples:92253195005, 92253195006
Matrix:Water
Analyzed
Mercury ug/L ND 0.20 07/01/15 17:33
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
2006740LABORATORY CONTROL SAMPLE:
LCSSpike
Mercury ug/L 4.95 97 80-120
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
2007452MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92255755005
2007453
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Mercury ug/L 5 103 80-120105 2 205ND5.2 5.3
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 33 of 56
40 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
MERP/5849
EPA 7471
EPA 7471
7471 Mercury
Associated Lab Samples:92253195002, 92253195003, 92253195004
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1240633
Associated Lab Samples:92253195002, 92253195003, 92253195004
Matrix:Solid
Analyzed
Mercury mg/kg ND 0.0078 06/16/15 12:20
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1240634LABORATORY CONTROL SAMPLE:
LCSSpike
Mercury mg/kg 0.084.078 108 80-120
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1240635MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92253145025
1240636
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Mercury mg/kg .0954 106 80-120105 3 20.093ND 0.10 0.097
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 34 of 56
41 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
MPRP/24673
EPA 3050
EPA 6010
6010 MET Solid
Associated Lab Samples:92253195002, 92253195003, 92253195004
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1240559
Associated Lab Samples:92253195002, 92253195003, 92253195004
Matrix:Solid
Analyzed
Aluminum mg/kg ND 4.9 06/15/15 00:48
Barium mg/kg ND 0.49 06/15/15 00:48
Beryllium mg/kg ND 0.049 06/15/15 00:48
Boron mg/kg ND 2.4 06/15/15 00:48
Calcium mg/kg ND 24.4 06/15/15 00:48
Chromium mg/kg ND 0.24 06/15/15 00:48
Copper mg/kg ND 0.24 06/15/15 00:48
Iron mg/kg 1.5J 1.9 06/15/15 00:48
Magnesium mg/kg ND 24.4 06/15/15 00:48
Manganese mg/kg ND 0.24 06/15/15 00:48
Molybdenum mg/kg ND 0.49 06/15/15 00:48
Nickel mg/kg ND 0.24 06/15/15 00:48
Potassium mg/kg ND 48.7 06/15/15 00:48
Sodium mg/kg ND 48.7 06/15/15 00:48
Strontium mg/kg ND 0.49 06/15/15 00:48
Zinc mg/kg ND 0.97 06/15/15 00:48
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1240560LABORATORY CONTROL SAMPLE:
LCSSpike
Aluminum mg/kg 126128 99 80-120
Barium mg/kg 12.912.8 101 80-120
Beryllium mg/kg 1.31.3 101 80-120
Boron mg/kg 124128 97 80-120
Calcium mg/kg 644639 101 80-120
Chromium mg/kg 12.712.8 100 80-120
Copper mg/kg 12.212.8 95 80-120
Iron mg/kg 128128 100 80-120
Magnesium mg/kg 641639 100 80-120
Manganese mg/kg 12.612.8 98 80-120
Molybdenum mg/kg 12.412.8 97 80-120
Nickel mg/kg 12.812.8 100 80-120
Potassium mg/kg 645639 101 80-120
Sodium mg/kg 669639 105 80-120
Strontium mg/kg 12.512.8 98 80-120
Zinc mg/kg 63.063.9 99 80-120
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 35 of 56
42 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1240561MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92253145025
1240563
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Aluminum mg/kg M1158-1320 75-125-1830 4 20146179001580015200
Barium mg/kg M115.8 355 75-125134 12 2014.6260 316 280
Beryllium mg/kg M11.57 61 75-12565 0 201.451.9 2.8 2.8
Boron mg/kg 158 79 75-12578 8 20146ND124115
Calcium mg/kg M17902075-1252 4 20733332034703330
Chromium mg/kg 15.8 75 75-12585 2 2014.614.9 26.9 27.4
Copper mg/kg 15.8 89 75-12579 11 2014.68.6 22.7 20.2
Iron mg/kg M1158-4470 75-125-4740 1 20146258001870018800
Magnesium mg/kg M1790-342 75-125-451 5 20733140001130010700
Manganese mg/kg M115.8 -600 75-125-817 4 2014.6694 599 574
Molybdenum mg/kg M115.8 73 75-12574 6 2014.6ND 11.6 10.9
Nickel mg/kg M115.8 65 75-12565 4 2014.610.8 21.1 20.3
Potassium mg/kg M1790-164 75-125-237 4 20733118001050010100
Sodium mg/kg 790 93 75-12593 7 20733ND823768
Strontium mg/kg M115.8 58 75-12550 6 2014.622.8 32.0 30.2
Zinc mg/kg M1793875-12535 3 2073.3125 155 151
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 36 of 56
43 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
MPRP/24674
EPA 3050
EPA 6020
6020 MET SOLID
Associated Lab Samples:92253195002, 92253195003, 92253195004
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1240564
Associated Lab Samples:92253195002, 92253195003, 92253195004
Matrix:Solid
Analyzed
Antimony mg/kg ND 0.050 N206/13/15 16:08
Arsenic mg/kg ND 0.050 06/13/15 16:08
Cadmium mg/kg ND 0.0060 06/13/15 16:08
Cobalt mg/kg ND 0.050 06/13/15 16:08
Lead mg/kg ND 0.050 06/13/15 16:08
Selenium mg/kg ND 0.050 06/13/15 16:08
Thallium mg/kg ND 0.050 06/13/15 16:08
Vanadium mg/kg ND 0.050 06/13/15 16:08
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1240565LABORATORY CONTROL SAMPLE:
LCSSpike
Antimony mg/kg 2.5 N22.6 96 80-120
Arsenic mg/kg 2.62.6 102 80-120
Cadmium mg/kg 0.25.26 99 80-120
Cobalt mg/kg 2.62.6 101 80-120
Lead mg/kg 2.62.6 101 80-120
Selenium mg/kg 2.52.6 96 80-120
Thallium mg/kg 2.72.6 104 80-120
Vanadium mg/kg 2.62.6 100 80-120
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1240566MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92253145025
1240567
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Antimony mg/kg M6,N23.14 52 75-12557 203.14ND ND ND
Arsenic mg/kg 3.14 82 75-12579 203.14ND 3.2J ND
Cadmium mg/kg M6.314 51 75-12541 20.314ND ND ND
Cobalt mg/kg M63.14 64 75-12567 1 203.147.5 9.5 9.6
Lead mg/kg M63.14 118 75-12574 203.14ND 5.9J 4.5J
Selenium mg/kg M63.14 63 75-12549 203.14ND ND ND
Thallium mg/kg 3.14 91 75-12593 203.14ND 3.3J 3.4J
Vanadium mg/kg M63.14 48 75-125115 2 203.1484.5 86.0 88.0
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 37 of 56
44 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
MPRP/55069
EPA 3020
EPA 6020A
6020A Water UPD4
Associated Lab Samples:92253195001
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1989760
Associated Lab Samples:92253195001
Matrix:Water
Analyzed
Aluminum ug/L ND 10.0 06/10/15 16:43
Antimony ug/L ND 0.50 06/10/15 16:43
Arsenic ug/L ND 0.50 06/10/15 16:43
Barium ug/L ND 0.30 06/10/15 16:43
Beryllium ug/L ND 0.20 06/10/15 16:43
Boron ug/L ND 5.0 06/10/15 16:43
Cadmium ug/L ND 0.080 06/10/15 16:43
Calcium ug/L ND 40.0 06/10/15 16:43
Chromium ug/L ND 0.50 06/10/15 16:43
Cobalt ug/L ND 0.50 06/10/15 16:43
Copper ug/L ND 1.0 06/10/15 16:43
Iron ug/L ND 50.0 06/10/15 16:43
Lead ug/L ND 0.10 06/10/15 16:43
Magnesium ug/L ND 10.0 06/10/15 16:43
Manganese ug/L ND 0.50 06/10/15 16:43
Molybdenum ug/L ND 0.50 06/10/15 16:43
Nickel ug/L ND 0.50 06/10/15 16:43
Potassium ug/L ND 50.0 06/11/15 07:45
Selenium ug/L ND 0.50 06/10/15 16:43
Sodium ug/L ND 50.0 06/10/15 16:43
Strontium ug/L ND 0.50 06/10/15 16:43
Thallium ug/L ND 0.10 06/10/15 16:43
Vanadium ug/L ND 1.0 06/10/15 16:43
Zinc ug/L ND 5.0 06/10/15 16:43
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1989761LABORATORY CONTROL SAMPLE:
LCSSpike
Aluminum ug/L 77.980 97 80-120
Antimony ug/L 76.480 96 80-120
Arsenic ug/L 77.680 97 80-120
Barium ug/L 81.380 102 80-120
Beryllium ug/L 80.880 101 80-120
Boron ug/L 78.380 98 80-120
Cadmium ug/L 77.280 96 80-120
Calcium ug/L 9551000 95 80-120
Chromium ug/L 79.480 99 80-120
Cobalt ug/L 84.980 106 80-120
Copper ug/L 81.380 102 80-120
Iron ug/L 10301000 103 80-120
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 38 of 56
45 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1989761LABORATORY CONTROL SAMPLE:
LCSSpike
Lead ug/L 78.180 98 80-120
Magnesium ug/L 9851000 98 80-120
Manganese ug/L 75.280 94 80-120
Molybdenum ug/L 77.280 97 80-120
Nickel ug/L 78.980 99 80-120
Potassium ug/L 10201000 102 80-120
Selenium ug/L 78.980 99 80-120
Sodium ug/L 10101000 101 80-120
Strontium ug/L 75.380 94 80-120
Thallium ug/L 82.980 104 80-120
Vanadium ug/L 77.280 96 80-120
Zinc ug/L 80.880 101 80-120
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1989762MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92253161011
1989763
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Aluminum ug/L M18020075-125215 4 2080173333345
Antimony ug/L 80 95 75-12595 0 2080ND76.3 76.2
Arsenic ug/L 80 100 75-12599 1 2080ND79.7 78.9
Barium ug/L 80 96 75-12595 0 20801.2 77.8 77.6
Beryllium ug/L 80 104 75-125100 3 2080ND82.9 80.1
Boron ug/L 80 96 75-12593 3 2080ND76.6 74.2
Cadmium ug/L 80 98 75-12598 0 2080ND78.1 78.0
Calcium ug/L 1000 102 75-125100 2 20100016811801170
Chromium ug/L 80 99 75-12599 0 20801.9 80.9 81.0
Cobalt ug/L 80 97 75-12597 0 2080ND78.1 77.8
Copper ug/L 80 101 75-125101 0 20801.2 82.0 82.2
Iron ug/L 1000 109 75-125109 0 20100033314201420
Lead ug/L 80 98 75-12597 1 20800.053J 78.4 77.7
Magnesium ug/L 1000 100 75-12598 3 20100042.1 1050 1020
Manganese ug/L 80 94 75-12594 0 20805.3 80.8 80.4
Molybdenum ug/L 80 96 75-12598 2 20800.39J 77.2 78.7
Nickel ug/L 80 99 75-12598 1 20800.32J 79.7 79.1
Potassium ug/L 1000 98 75-125100 2 20100039.0J 1010 1040
Selenium ug/L 80 104 75-12598 6 2080ND83.5 78.3
Sodium ug/L 1000 89 75-12588 1 20100033.9J 928 915
Strontium ug/L 80 96 75-12594 1 20801.2 77.6 76.7
Thallium ug/L 80 105 75-125103 1 2080ND83.9 82.8
Vanadium ug/L 80 95 75-12596 1 2080ND76.5 77.2
Zinc ug/L 80 104 75-12599 5 2080ND84.9 80.9
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 39 of 56
46 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
MPRP/55571
EPA 3020
EPA 6020A
6020A Water UPD4
Associated Lab Samples:92253195005, 92253195006
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:2006731
Associated Lab Samples:92253195005, 92253195006
Matrix:Water
Analyzed
Aluminum ug/L ND 10.0 07/01/15 00:15
Antimony ug/L ND 0.50 07/01/15 00:15
Arsenic ug/L ND 0.50 07/01/15 00:15
Barium ug/L ND 0.30 07/01/15 00:15
Beryllium ug/L ND 0.20 07/01/15 00:15
Boron ug/L ND 5.0 07/01/15 00:15
Cadmium ug/L ND 0.080 07/01/15 00:15
Calcium ug/L ND 40.0 07/02/15 07:11
Chromium ug/L ND 0.50 07/01/15 00:15
Cobalt ug/L ND 0.50 07/01/15 00:15
Copper ug/L ND 1.0 07/02/15 07:11
Iron ug/L ND 50.0 07/01/15 00:15
Lead ug/L ND 0.10 07/01/15 00:15
Magnesium ug/L ND 10.0 07/01/15 00:15
Manganese ug/L ND 0.50 07/01/15 00:15
Molybdenum ug/L ND 0.50 07/01/15 00:15
Nickel ug/L ND 0.50 07/01/15 00:15
Potassium ug/L ND 50.0 07/01/15 00:15
Selenium ug/L ND 0.50 07/01/15 00:15
Sodium ug/L ND 50.0 07/01/15 00:15
Strontium ug/L ND 0.50 07/01/15 00:15
Thallium ug/L ND 0.10 07/01/15 00:15
Vanadium ug/L ND 1.0 07/01/15 00:15
Zinc ug/L ND 5.0 07/01/15 00:15
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
2006732LABORATORY CONTROL SAMPLE:
LCSSpike
Aluminum ug/L 76.180 95 80-120
Antimony ug/L 76.280 95 80-120
Arsenic ug/L 77.580 97 80-120
Barium ug/L 79.180 99 80-120
Beryllium ug/L 82.080 103 80-120
Boron ug/L 87.180 109 80-120
Cadmium ug/L 77.980 97 80-120
Calcium ug/L 10301000 103 80-120
Chromium ug/L 78.180 98 80-120
Cobalt ug/L 78.480 98 80-120
Copper ug/L 77.480 97 80-120
Iron ug/L 9761000 98 80-120
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 40 of 56
47 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
2006732LABORATORY CONTROL SAMPLE:
LCSSpike
Lead ug/L 77.080 96 80-120
Magnesium ug/L 9641000 96 80-120
Manganese ug/L 78.480 98 80-120
Molybdenum ug/L 76.880 96 80-120
Nickel ug/L 78.280 98 80-120
Potassium ug/L 9791000 98 80-120
Selenium ug/L 78.280 98 80-120
Sodium ug/L 9941000 99 80-120
Strontium ug/L 77.380 97 80-120
Thallium ug/L 76.680 96 80-120
Vanadium ug/L 78.680 98 80-120
Zinc ug/L 77.280 97 80-120
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
2007450MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92255755020
2007451
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Aluminum ug/L 80 111 75-125110 0 20805.6J 94.1 93.8
Antimony ug/L 80 98 75-12596 2 2080ND78.5 76.7
Arsenic ug/L 80 101 75-12597 4 2080ND81.1 77.9
Barium ug/L 80 101 75-12599 2 20800.26J 80.8 79.3
Beryllium ug/L 80 100 75-125101 1 2080ND79.8 80.6
Boron ug/L 80 104 75-125101 3 2080ND84.4 81.9
Cadmium ug/L 80 101 75-12599 2 2080ND80.7 79.4
Calcium ug/L 1000 103 75-125101 2 20100076.6 1100 1090
Chromium ug/L 80 101 75-12599 3 2080ND81.2 79.1
Cobalt ug/L 80 103 75-12598 4 2080ND82.2 78.6
Copper ug/L 80 102 75-12598 4 20800.32J 81.9 78.9
Iron ug/L 1000 101 75-12598 3 20100014.7J 1030 996
Lead ug/L 80 99 75-12597 3 2080ND79.3 77.2
Magnesium ug/L 1000 102 75-12599 3 2010007.9J 1030 1000
Manganese ug/L 80 102 75-125100 2 20800.42J 81.6 80.2
Molybdenum ug/L 80 100 75-12598 2 2080ND80.0 78.7
Nickel ug/L 80 105 75-125100 4 2080ND84.0 80.4
Potassium ug/L 1000 104 75-125101 3 20100018.5J 1050 1030
Selenium ug/L 80 103 75-12598 4 2080ND82.1 78.6
Sodium ug/L 1000 104 75-12597 6 20100031.9J 1070 1010
Strontium ug/L 80 100 75-12599 1 20800.50 80.6 79.8
Thallium ug/L 80 101 75-12599 2 2080ND81.1 79.2
Vanadium ug/L 80 102 75-12599 3 2080ND82.0 79.4
Zinc ug/L 80 106 75-12594 10 20808.0 92.6 83.4
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 41 of 56
48 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
PMST/7948
ASTM D2974-87
ASTM D2974-87
Dry Weight/Percent Moisture
Associated Lab Samples:92253195002, 92253195003, 92253195004
Parameter Units
Dup
Result
Max
RPD QualifiersRPDResult
92251982001
1478682SAMPLE DUPLICATE:
Percent Moisture %26.1 19 2531.7
Parameter Units
Dup
Result
Max
RPD QualifiersRPDResult
92253195004
1478683SAMPLE DUPLICATE:
Percent Moisture %19.4 2 2519.7
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 42 of 56
49 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
WET/38033
EPA 9045
EPA 9045
9045 pH
Associated Lab Samples:92253195002, 92253195003, 92253195004
Parameter Units
Dup
Result
Max
RPD QualifiersRPDResult
92253352003
1481715SAMPLE DUPLICATE:
pH at 25 Degrees C Std. Units 7.0 D63107.2
Parameter Units
Dup
Result
Max
RPD QualifiersRPDResult
92253161005
1481716SAMPLE DUPLICATE:
pH at 25 Degrees C Std. Units 5.0 D68105.4
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 43 of 56
50 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
WETA/23324
EPA 300.0
EPA 300.0
300.0 IC Anions
Associated Lab Samples:92253195002, 92253195003
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1485896
Associated Lab Samples:92253195002, 92253195003
Matrix:Water
Analyzed
Sulfate mg/L 2.3 2.0 06/16/15 15:20
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1485897LABORATORY CONTROL SAMPLE:
LCSSpike
Sulfate mg/L 19.620 98 90-110
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1485898MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92252532003
1485899
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Sulfate mg/L 20 98 99 1206.3 26.0 26.2
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 44 of 56
51 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
WETA/23372
EPA 353.2
EPA 353.2
353.2 Nitrate + Nitrite, Unpres.
Associated Lab Samples:92253195002, 92253195003
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1488925
Associated Lab Samples:92253195002, 92253195003
Matrix:Water
Analyzed
Nitrogen, Nitrate mg/L 0.14 0.020 Z206/18/15 17:00
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1488926LABORATORY CONTROL SAMPLE:
LCSSpike
Nitrogen, Nitrate mg/L 2.52.5 102 90-110
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1488927MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92252532003
1488928
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Nitrogen, Nitrate mg/L H12.5 98 90-11097 1 102.5ND 2.6 2.6
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 45 of 56
52 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
WETA/23354
SM 4500-Cl-E
SM 4500-Cl-E
4500 Chloride
Associated Lab Samples:92253195002
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1487997
Associated Lab Samples:92253195002
Matrix:Water
Analyzed
Chloride mg/L ND 1.0 06/18/15 04:51
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1487998LABORATORY CONTROL SAMPLE:
LCSSpike
Chloride mg/L 19.820 99 90-110
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1487999MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92252532003
1488000
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Chloride mg/L M1208690-11086 0 1020ND17.3 17.4
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 46 of 56
53 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
WETA/23374
SM 4500-Cl-E
SM 4500-Cl-E
4500 Chloride
Associated Lab Samples:92253195003
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1489297
Associated Lab Samples:92253195003
Matrix:Water
Analyzed
Chloride mg/L ND 1.0 06/19/15 05:16
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1489298LABORATORY CONTROL SAMPLE:
LCSSpike
Chloride mg/L 20.320 102 90-110
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1489299MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92253890015
1489300
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Chloride mg/L 45.6 109 90-110109 0 1045.6ND 49.6 49.7
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1489301MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92254310001
1489302
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Chloride mg/L H328.1 101 90-110101 0 1028.1ND 29.5 29.4
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 47 of 56
54 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
WETA/47190
EPA 9056
EPA 9056
9056 IC Anions
Associated Lab Samples:92253195002, 92253195003, 92253195004
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1238041
Associated Lab Samples:
Matrix:Solid
Analyzed
Chloride mg/kg ND 49.9 06/11/15 08:38
Sulfate mg/kg ND 49.9 06/11/15 08:38
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1238042LABORATORY CONTROL SAMPLE:
LCSSpike
Chloride mg/kg 472502 94 80-120
Sulfate mg/kg 470502 94 80-120
Parameter Units
MS
Result
% Rec
Limits Qualifiers% RecConc.
1238044MATRIX SPIKE SAMPLE:
MSSpike
Result
92253145022
Chloride mg/kg 576653 88 80-120ND
Sulfate mg/kg 656653 85 80-120ND
Parameter Units
Dup
Result
Max
RPD QualifiersRPDResult
92253145022
1238043SAMPLE DUPLICATE:
Chloride mg/kg ND 20ND
Sulfate mg/kg ND 20ND
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 48 of 56
55 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
WETA/47192
EPA 9056
EPA 9056
9056 IC Anions
Associated Lab Samples:92253195002, 92253195003, 92253195004
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1238051
Associated Lab Samples:
Matrix:Solid
Analyzed
Nitrate as N mg/kg ND 5.0 06/11/15 08:38
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1238052LABORATORY CONTROL SAMPLE:
LCSSpike
Nitrate as N mg/kg 49.450.2 98 80-120
Parameter Units
MS
Result
% Rec
Limits Qualifiers% RecConc.
1238054MATRIX SPIKE SAMPLE:
MSSpike
Result
92253145022
Nitrate as N mg/kg 60.8 H365.3 91 80-120ND
Parameter Units
Dup
Result
Max
RPD QualifiersRPDResult
92253145022
1238053SAMPLE DUPLICATE:
Nitrate as N mg/kg ND H320ND
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 49 of 56
56 of 64
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92253195
J15060206
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
WETA/29243
EPA 9060 Modified
EPA 9060 Modified
9060 TOC Average
Associated Lab Samples:92253195002, 92253195003, 92253195004
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1184234
Associated Lab Samples:
Matrix:Solid
Analyzed
Mean Total Organic Carbon mg/kg ND 600 06/27/15 16:37
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1184235LABORATORY CONTROL SAMPLE:
LCSSpike
Mean Total Organic Carbon mg/kg 116000120000 96 80-120
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1184236MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92253195003
1184237
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Mean Total Organic Carbon mg/kg 37200 123 50-150119 2 3037200492009510093500
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1184238MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92253195002
1184239
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Mean Total Organic Carbon mg/kg 62800 102 50-150100 2 306190085100149000147000
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 50 of 56
57 of 64
#=QL#
QUALIFIERS
Pace Project No.:
Project:
92253195
J15060206
DEFINITIONS
DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot.
ND - Not Detected at or above adjusted reporting limit.
J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit.
MDL - Adjusted Method Detection Limit.
PQL - Practical Quantitation Limit.
RL - Reporting Limit.
S - Surrogate
1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is
a combined concentration.
Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values.
LCS(D) - Laboratory Control Sample (Duplicate)
MS(D) - Matrix Spike (Duplicate)
DUP - Sample Duplicate
RPD - Relative Percent Difference
NC - Not Calculable.
SG - Silica Gel - Clean-Up
U - Indicates the compound was analyzed for, but not detected.
Acid preservation may not be appropriate for 2 Chloroethylvinyl ether, Styrene, and Vinyl chloride.
A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA
Method 8260.
N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for
each analyte is a combined concentration.
Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes.
TNI - The NELAC Institute.
LABORATORIES
Pace Analytical Services - AshevillePASI-A
Pace Analytical Services - CharlottePASI-C
Pace Analytical Services - Green BayPASI-G
Pace Analytical Services - MinneapolisPASI-M
Pace Analytical Services - Ormond BeachPASI-O
BATCH QUALIFIERS
Batch: ICPM/10002
Sample was diluted due to the presence of high levels of non-target analytes or other matrix interference.[1]
Batch: ICP/15063
Sample was diluted due to the presence of high levels of non-target analytes or other matrix interference.[1]
ANALYTE QUALIFIERS
Analyte was detected in the associated method blank.B
Sample was diluted due to the presence of high levels of non-target analytes or other matrix interference.D3
The relative percent difference (RPD) between the sample and sample duplicate exceeded laboratory control limits.D6
Analysis conducted outside the EPA method holding time.H1
Sample was received or analysis requested beyond the recognized method holding time.H3
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 51 of 56
58 of 64
#=QL#
QUALIFIERS
Pace Project No.:
Project:
92253195
J15060206
ANALYTE QUALIFIERS
Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.M1
Matrix spike and Matrix spike duplicate recovery not evaluated against control limits due to sample dilution.M6
The lab does not hold TNI accreditation for this parameter.N2
Analyte present in the associated method blank above the detection limit.Z2
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 52 of 56
59 of 64
#=CR#
QUALITY CONTROL DATA CROSS REFERENCE TABLE
Pace Project No.:
Project:
92253195
J15060206
Lab ID Sample ID QC Batch Method QC Batch Analytical Method
Analytical
Batch
92253195002 MPRP/24673 ICP/150632015017619EPA 3050 EPA 6010
92253195003 MPRP/24673 ICP/150632015017620EPA 3050 EPA 6010
92253195004 MPRP/24673 ICP/150632015017621EPA 3050 EPA 6010
92253195002 MPRP/24674 ICPM/100022015017619EPA 3050 EPA 6020
92253195003 MPRP/24674 ICPM/100022015017620EPA 3050 EPA 6020
92253195004 MPRP/24674 ICPM/100022015017621EPA 3050 EPA 6020
92253195001 MPRP/55069 ICPM/247392015017618EPA 3020 EPA 6020A
92253195005 MPRP/55571 ICPM/251092015017619 SPLP EPA 3020 EPA 6020A
92253195006 MPRP/55571 ICPM/251092015017620 SPLP EPA 3020 EPA 6020A
92253195001 MERP/13814 MERC/160862015017618EPA 7470A EPA 7470A
92253195005 MERP/14018 MERC/163642015017619 SPLP EPA 7470A EPA 7470A
92253195006 MERP/14018 MERC/163642015017620 SPLP EPA 7470A EPA 7470A
92253195002 MERP/5849 MERC/58382015017619EPA 7471 EPA 7471
92253195003 MERP/5849 MERC/58382015017620EPA 7471 EPA 7471
92253195004 MERP/5849 MERC/58382015017621EPA 7471 EPA 7471
92253195002 PMST/79482015017619ASTM D2974-87
92253195003 PMST/79482015017620ASTM D2974-87
92253195004 PMST/79482015017621ASTM D2974-87
92253195002 WET/380332015017619EPA 9045
92253195003 WET/380332015017620EPA 9045
92253195004 WET/380332015017621EPA 9045
92253195002 WETA/233242015017619EPA 300.0
92253195003 WETA/233242015017620EPA 300.0
92253195002 WETA/233722015017619EPA 353.2
92253195003 WETA/233722015017620EPA 353.2
92253195002 WETA/233542015017619SM 4500-Cl-E
92253195003 WETA/233742015017620SM 4500-Cl-E
92253195002 WETA/471902015017619EPA 9056
92253195003 WETA/471902015017620EPA 9056
92253195004 WETA/471902015017621EPA 9056
92253195002 WETA/471922015017619EPA 9056
92253195003 WETA/471922015017620EPA 9056
92253195004 WETA/471922015017621EPA 9056
92253195002 WETA/292432015017619EPA 9060 Modified
92253195002 WETA/292492015017619EPA 9060 Modified
92253195003 WETA/292432015017620EPA 9060 Modified
92253195003 WETA/292492015017620EPA 9060 Modified
92253195004 WETA/292432015017621EPA 9060 Modified
92253195004 WETA/292492015017621EPA 9060 Modified
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 53 of 56
60 of 64
#=CR#
QUALITY CONTROL DATA CROSS REFERENCE TABLE
Pace Project No.:
Project:
92253195
J15060206
Lab ID Sample ID QC Batch Method QC Batch Analytical Method
Analytical
Batch
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 07/06/2015 01:32 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 54 of 56
61 of 64
Page 55 of 56
62 of 64
Page 56 of 56
63 of 64
64 of 64