HomeMy WebLinkAboutNC0038377_J15050632 Report_2017110113339 Hagers Ferry Road
Huntersville, NC 28078-7929
McGuire Nuclear Complex - MG03A2
Phone: 980-875-5245 Fax: 980-875-4349
Order Summary Report
Analytical Laboratory
Order Number: J15050632
Project Name:MAYO STEAM - AB GW ASSESSMENT SOIL
Lab Contact:Margaret Galvin-Karr
Date:6/18/2015
Customer Address:
Customer Name(s):Tim Hunsucker, Jerry Wylie, Kathy Webb, John Toepfer
Phone: 980-875-5219
Report Authorized By:
(Signature)
Program Comments:
Please contact the Program Manager (Margaret Galvin-Karr) with any questions regarding this report.
Data Flags & Calculations:
Any analytical tests or individual analytes within a test flagged with a Qualifier indicate a deviation from the method quality
system or quality control requirement. The qualifier description is found at the end of the Certificate of Analysis (sample results)
under the qualifiers heading. All results are reported on a dry weight basis unless otherwise noted. Subcontracted data
included on the Duke Certificate of Analysis is to be used as information only. Certified vendor results can be found in the
subcontracted lab final report. Duke Energy Analytical Laboratory subcontracts analyses to other vendor laboratories that have
been qualified by Duke Energy to perform these analyses except where noted.
Data Package:
This data package includes analytical results that are applicable only to the samples described in this narrative. An estimation of
the uncertainty of measurement for the results in the report is available upon request. This report shall not be reproduced, except
in full, without the written consent of the Analytical Laboratory. Please contact the Analytical laboratory with any questions. The
order of individual sections within this report is as follows:
Job Summary Report, Sample Identification, Technical Validation of Data Package, Analytical Laboratory Certificate of Analysis,
Analytical Laboratory QC Reports, Sub-contracted Laboratory Results, Customer Specific Data Sheets, Reports &
Documentation, Customer Database Entries, Test Case Narratives, Chain of Custody (COC)
Certification:
The Analytical Laboratory holds the following State Certifications : North Carolina (DENR) Certificate #248, South Carolina
(DHEC) Laboratory ID # 99005. Contact the Analytical Laboratory for definitive information about the certification status of
specific methods.
Margaret Galvin-Karr
1 of 55
Sample ID's & Descriptions:
Sample ID Plant/Station
Collection
Date and Time Collected By Sample Description
2015015768 MAYO STEAM 19-May-15 2:15 PM illegible ABMW-3EB
2015015769 MAYO STEAM 20-May-15 3:20 PM illegible ABMW-3SEB
2015015770 MAYO STEAM 20-May-15 2:15 PM illegible ABMW-3S(51.0-53.0)
3 Total Samples
2 of 55
COC and .pdf report are in agreement with sample totals
and analyses (compliance programs and procedures).
All Results are less than the laboratory reporting limits.
All laboratory QA/QC requirements are acceptable.
Yes No
Technical Validation Review
Checklist:
Yes No
Yes No
Report Sections Included:
Job Summary Report Sub-contracted Laboratory Results
Sample Identification Customer Specific Data Sheets, Reports, & Documentation
Technical Validation of Data Package Customer Database Entries
Analytical Laboratory Certificate of Analysis
Analytical Laboratory QC Report
Chain of Custody
Reviewed By: Date:
Electronic Data Deliverable (EDD) Sent Separately
3 of 55
Certificate of Laboratory Analysis
This report shall not be reproduced, except in full.
Order # J15050632
2015015768
Collection Date: 19-May-15 2:15 PM
Site:ABMW-3EB
Matrix: SOIL
Analyte Analysis Date/TimeMethodUnits Qualifiers RDLResult
Sample #:
AnalystDF
METALS ANALYSIS BY VENDOR LAB - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
4 of 55
Certificate of Laboratory Analysis
This report shall not be reproduced, except in full.
Order # J15050632
2015015769
Collection Date: 20-May-15 3:20 PM
Site:ABMW-3SEB
Matrix: SOIL
Analyte Analysis Date/TimeMethodUnits Qualifiers RDLResult
Sample #:
AnalystDF
METALS ANALYSIS BY VENDOR LAB - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
5 of 55
Certificate of Laboratory Analysis
This report shall not be reproduced, except in full.
Order # J15050632
2015015770
Collection Date: 20-May-15 2:15 PM
Site:ABMW-3S(51.0-53.0)
Matrix: SOIL
Analyte Analysis Date/TimeMethodUnits Qualifiers RDLResult
Sample #:
AnalystDF
PERCENT SOLIDS - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
DIONEX ANIONS BY VENDOR - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
METALS ANALYSIS BY VENDOR LAB - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
PH IN SOIL - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
SPLP LEACHATE - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
TOTAL ORGANIC CARBON IN SOILS - (Analysis Performed by Pace Laboratories)
Vendor Parameter Complete Vendor Method V_PACE
6 of 55
#=CL#
June 15, 2015
LIMS USE: FR - PROGRAM MANAGER
LIMS OBJECT ID: 92251236
92251236
Project:
Pace Project No.:
RE:
Program Manager
Duke Energy
13339 Hagers Ferry Road
Bldg. 7405 MG30A2
Huntersville, NC 28078
J15050632
Dear Program Manager:
Enclosed are the analytical results for sample(s) received by the laboratory on May 22, 2015. The
results relate only to the samples included in this report. Results reported herein conform to the
most current TNI standards and the laboratory's Quality Assurance Manual, where applicable, unless
otherwise noted in the body of the report.
Analyses were performed at the Pace Analytical Services location indicated on the sample analyte
page for analysis unless otherwise footnoted.
If you have any questions concerning this report, please feel free to contact me.
Sincerely,
Kevin Herring
kevin.herring@pacelabs.com
HORIZON Database Administrator
Enclosures
cc:Marge Galvin-Karr, Duke Energy
Program Manager, Duke Energy
Mary Ann Ogle, Duke Energy
Rodney Wike, Duke Energy
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 1 of 48
7 of 55
#=CP#
CERTIFICATIONS
Pace Project No.:
Project:
92251236
J15050632
Minnesota Certification IDs
1700 Elm Street SE Suite 200, Minneapolis, MN 55414
A2LA Certification #: 2926.01
Alaska Certification #: UST-078
Alaska Certification #MN00064
Alabama Certification #40770
Arizona Certification #: AZ-0014
Arkansas Certification #: 88-0680
California Certification #: 01155CA
Colorado Certification #Pace
Connecticut Certification #: PH-0256
EPA Region 8 Certification #: 8TMS-L
Florida/NELAP Certification #: E87605
Guam Certification #:14-008r
Georgia Certification #: 959
Georgia EPD #: Pace
Idaho Certification #: MN00064
Hawaii Certification #MN00064
Illinois Certification #: 200011
Indiana Certification#C-MN-01
Iowa Certification #: 368
Kansas Certification #: E-10167
Kentucky Dept of Envi. Protection - DW #90062
Kentucky Dept of Envi. Protection - WW #:90062
Louisiana DEQ Certification #: 3086
Louisiana DHH #: LA140001
Maine Certification #: 2013011
Maryland Certification #: 322
Michigan DEPH Certification #: 9909
Minnesota Certification #: 027-053-137
Mississippi Certification #: Pace
Montana Certification #: MT0092
Nevada Certification #: MN_00064
Nebraska Certification #: Pace
New Jersey Certification #: MN-002
New York Certification #: 11647
North Carolina Certification #: 530
North Carolina State Public Health #: 27700
North Dakota Certification #: R-036
Ohio EPA #: 4150
Ohio VAP Certification #: CL101
Oklahoma Certification #: 9507
Oregon Certification #: MN200001
Oregon Certification #: MN300001
Pennsylvania Certification #: 68-00563
Puerto Rico Certification
Saipan (CNMI) #:MP0003
South Carolina #:74003001
Texas Certification #: T104704192
Tennessee Certification #: 02818
Utah Certification #: MN000642013-4
Virginia DGS Certification #: 251
Virginia/VELAP Certification #: Pace
Washington Certification #: C486
West Virginia Certification #: 382
West Virginia DHHR #:9952C
Wisconsin Certification #: 999407970
Ormond Beach Certification IDs
8 East Tower Circle, Ormond Beach, FL 32174
Alabama Certification #: 41320
Connecticut Certification #: PH-0216
Delaware Certification: FL NELAC Reciprocity
Florida Certification #: E83079
Georgia Certification #: 955
Guam Certification: FL NELAC Reciprocity
Hawaii Certification: FL NELAC Reciprocity
Illinois Certification #: 200068
Indiana Certification: FL NELAC Reciprocity
Kansas Certification #: E-10383
Kentucky Certification #: 90050
Louisiana Certification #: FL NELAC Reciprocity
Louisiana Environmental Certificate #: 05007
Maryland Certification: #346
Massachusetts Certification #: M-FL1264
Michigan Certification #: 9911
Mississippi Certification: FL NELAC Reciprocity
Missouri Certification #: 236
Montana Certification #: Cert 0074
Nebraska Certification: NE-OS-28-14
Nevada Certification: FL NELAC Reciprocity
New Hampshire Certification #: 2958
New Jersey Certification #: FL765
New York Certification #: 11608
North Carolina Environmental Certificate #: 667
Pennsylvania Certification #: 68-00547
Puerto Rico Certification #: FL01264
South Carolina Certification: #96042001
Tennessee Certification #: TN02974
Texas Certification: FL NELAC Reciprocity
US Virgin Islands Certification: FL NELAC Reciprocity
Virginia Environmental Certification #: 460165
Washington Certification #: C955
West Virginia Certification #: 9962C
Wisconsin Certification #: 399079670
Wyoming (EPA Region 8): FL NELAC Reciprocity
Green Bay Certification IDs
1241 Bellevue Street, Green Bay, WI 54302
Florida/NELAP Certification #: E87948
Illinois Certification #: 200050
Kentucky Certification #: 82
Louisiana Certification #: 04168
Minnesota Certification #: 055-999-334
North Dakota Certification #: R-150
South Carolina Certification #: 83006001
Texas Certification #: T104704529-14-1
US Dept of Agriculture #: S-76505
Wisconsin Certification #: 405132750
Asheville Certification IDs
2225 Riverside Drive, Asheville, NC 28804
Florida/NELAP Certification #: E87648
Massachusetts Certification #: M-NC030
North Carolina Drinking Water Certification #: 37712
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 2 of 48
8 of 55
#=CP#
CERTIFICATIONS
Pace Project No.:
Project:
92251236
J15050632
Asheville Certification IDs
North Carolina Wastewater Certification #: 40
South Carolina Certification #: 99030001
West Virginia Certification #: 356
Virginia/VELAP Certification #: 460222
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 3 of 48
9 of 55
#=SS#
SAMPLE SUMMARY
Pace Project No.:
Project:
92251236
J15050632
Lab ID Sample ID Matrix Date Collected Date Received
92251236001 2015015768 Water 05/19/15 14:15 05/22/15 14:40
92251236002 2015015769 Water 05/20/15 15:20 05/22/15 14:40
92251236003 2015015770 Solid 05/20/15 14:15 05/22/15 14:40
92251236004 2015015770 SPLP Water 05/20/15 14:15 05/22/15 14:40
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 4 of 48
10 of 55
#=SA#
SAMPLE ANALYTE COUNT
Pace Project No.:
Project:
92251236
J15050632
Lab ID Sample ID Method
Analytes
Reported LaboratoryAnalysts
92251236001 2015015768 EPA 6020A 24 PASI-MRJS
EPA 7470A 1 PASI-MJDD
92251236002 2015015769 EPA 6020A 24 PASI-MRJS
EPA 7470A 1 PASI-MJDD
92251236003 2015015770 EPA 6010 17 PASI-OCKJ
EPA 6020 7 PASI-OCRT
EPA 7471 1 PASI-OCRT
ASTM D2974-87 1 PASI-OMLO
EPA 9045 1 PASI-AMAB
EPA 300.0 1 PASI-AAES2
EPA 353.2 1 PASI-ADMN
SM 4500-Cl-E 1 PASI-ASER
EPA 9056 2 PASI-OCMB
EPA 9056 1 PASI-OCMB
EPA 9060 6 PASI-GTJJ
92251236004 2015015770 SPLP EPA 6020A 24 PASI-MTT3
EPA 7470A 1 PASI-MLMW
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 5 of 48
11 of 55
#=HO#
SUMMARY OF DETECTION
Pace Project No.:
Project:
92251236
J15050632
Parameters AnalyzedResult
Lab Sample ID
Report Limit QualifiersUnitsMethod
Client Sample ID
92251236001 2015015768
Aluminum 18.1 ug/L 05/29/15 18:0310.0EPA 6020A
Barium 0.70 ug/L 05/29/15 18:030.30EPA 6020A
Calcium 134 ug/L 05/29/15 18:0340.0EPA 6020A
Chromium 1.2 ug/L 05/29/15 18:030.50EPA 6020A
Cobalt 3.3 ug/L 05/29/15 18:030.50EPA 6020A
Iron 186 ug/L 05/29/15 18:0350.0EPA 6020A
Lead 0.070J ug/L 05/29/15 18:030.10EPA 6020A
Magnesium 9.9J ug/L 05/29/15 18:0310.0EPA 6020A
Manganese 7.0 ug/L 05/29/15 18:030.50EPA 6020A
Molybdenum 0.27J ug/L 05/29/15 18:030.50EPA 6020A
Potassium 29.3J ug/L 05/29/15 18:0350.0EPA 6020A
Strontium 0.16J ug/L 05/29/15 18:030.50EPA 6020A
Zinc 3.6J ug/L 05/29/15 18:035.0EPA 6020A
92251236002 2015015769
Aluminum 41.7 ug/L 05/29/15 18:4110.0EPA 6020A
Barium 1.5 ug/L 05/29/15 18:410.30EPA 6020A
Boron 2.3J ug/L 05/29/15 18:415.0EPA 6020A
Calcium 298 ug/L 05/29/15 18:4140.0EPA 6020A
Chromium 2.1 ug/L 05/29/15 18:410.50EPA 6020A
Cobalt 61.1 ug/L 05/29/15 18:410.50EPA 6020A
Copper 1.1 ug/L 05/29/15 18:411.0EPA 6020A
Iron 321 ug/L 05/29/15 18:4150.0EPA 6020A
Magnesium 59.5 ug/L 05/29/15 18:4110.0EPA 6020A
Manganese 9.9 ug/L 05/29/15 18:410.50EPA 6020A
Molybdenum 0.32J ug/L 05/29/15 18:410.50EPA 6020A
Nickel 0.64 ug/L 05/29/15 18:410.50EPA 6020A
Potassium 90.1 ug/L 05/29/15 18:4150.0EPA 6020A
Sodium 182 ug/L 05/29/15 18:4150.0EPA 6020A
Strontium 0.80 ug/L 05/29/15 18:410.50EPA 6020A
Zinc 5.2 ug/L 05/29/15 18:415.0EPA 6020A
92251236003 2015015770
Aluminum 10600 mg/kg 06/04/15 01:3534.0EPA 6010
Barium 56.1 mg/kg 06/04/15 01:353.4EPA 6010
Beryllium 0.90 mg/kg 06/04/15 01:350.34EPA 6010
Chromium 1.3J mg/kg 06/04/15 01:351.7EPA 6010
Copper 9.0 mg/kg 06/04/15 01:351.7EPA 6010
Iron 16900 mg/kg 06/04/15 01:3513.6EPA 6010
Magnesium 4210 mg/kg 06/04/15 01:35170EPA 6010
Manganese 319 mg/kg 06/04/15 01:351.7EPA 6010
Potassium 2980 mg/kg 06/04/15 01:35340EPA 6010
Strontium 3.3J mg/kg 06/04/15 01:353.4EPA 6010
Zinc 27.7 mg/kg 06/04/15 01:356.8EPA 6010
Cobalt 6.6J mg/kg 06/03/15 19:566.8EPA 6020
Vanadium 28.8 mg/kg 06/03/15 19:566.8EPA 6020
Mercury 0.021 mg/kg 06/03/15 18:180.010EPA 7471
Percent Moisture 24.6 %06/05/15 09:170.10ASTM D2974-87
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 6 of 48
12 of 55
#=HO#
SUMMARY OF DETECTION
Pace Project No.:
Project:
92251236
J15050632
Parameters AnalyzedResult
Lab Sample ID
Report Limit QualifiersUnitsMethod
Client Sample ID
92251236003 2015015770
pH at 25 Degrees C 5.9 Std. Units 06/03/15 12:00 H10.10EPA 9045
Sulfate 3.0 mg/L 06/10/15 10:13 B2.7EPA 300.0
RSD%1.6 %06/12/15 09:11EPA 9060
92251236004 2015015770 SPLP
Aluminum 268 ug/L 06/10/15 16:0910.0EPA 6020A
Arsenic 0.17J ug/L 06/10/15 16:090.50EPA 6020A
Barium 80.2 ug/L 06/10/15 16:090.30EPA 6020A
Boron 85.6 ug/L 06/10/15 16:095.0EPA 6020A
Calcium 170 ug/L 06/10/15 16:0940.0EPA 6020A
Chromium 0.55 ug/L 06/10/15 16:090.50EPA 6020A
Cobalt 0.15J ug/L 06/10/15 16:090.50EPA 6020A
Copper 0.54J ug/L 06/10/15 16:091.0EPA 6020A
Iron 95.1 ug/L 06/10/15 16:0950.0EPA 6020A
Lead 0.072J ug/L 06/10/15 16:090.10EPA 6020A
Magnesium 40.8 ug/L 06/10/15 16:0910.0EPA 6020A
Manganese 4.8 ug/L 06/10/15 16:090.50EPA 6020A
Nickel 0.18J ug/L 06/10/15 16:090.50EPA 6020A
Potassium 102 ug/L 06/10/15 16:0950.0EPA 6020A
Sodium 1870 ug/L 06/10/15 16:0950.0EPA 6020A
Strontium 3.2 ug/L 06/10/15 16:090.50EPA 6020A
Vanadium 0.61J ug/L 06/10/15 16:091.0EPA 6020A
Zinc 56.7 ug/L 06/10/15 16:095.0EPA 6020A
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 7 of 48
13 of 55
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92251236
J15050632
Method:
Client:Duke Energy
EPA 6010
Date:June 15, 2015
Description:6010 MET ICP
General Information:
1 sample was analyzed for EPA 6010. All samples were received in acceptable condition with any exceptions noted below.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Sample Preparation:
The samples were prepared in accordance with EPA 3050 with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
QC Batch: MPRP/24465
A matrix spike and/or matrix spike duplicate (MS/MSD) were performed on the following sample(s): 92251157007
M1: Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.
• MS (Lab ID: 1229849)
• Aluminum
• Iron
• Manganese
• MSD (Lab ID: 1229850)
• Aluminum
• Iron
Additional Comments:
Batch Comments:
Sample was diluted due to the presence of high levels of non-target analytes or other matrix interference.
• QC Batch: ICP / 14943
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 8 of 48
14 of 55
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92251236
J15050632
Method:
Client:Duke Energy
EPA 6020
Date:June 15, 2015
Description:6020 MET ICPMS
General Information:
1 sample was analyzed for EPA 6020. All samples were received in acceptable condition with any exceptions noted below.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Sample Preparation:
The samples were prepared in accordance with EPA 3050 with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Internal Standards:
All internal standards were within QC limits with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
QC Batch: MPRP/24466
A matrix spike and/or matrix spike duplicate (MS/MSD) were performed on the following sample(s): 92251157007
M6: Matrix spike and Matrix spike duplicate recovery not evaluated against control limits due to sample dilution.
• MS (Lab ID: 1229856)
• Arsenic
• Thallium
• MSD (Lab ID: 1229857)
• Thallium
Additional Comments:
Batch Comments:
Sample was diluted due to the presence of high levels of non-target analytes or other matrix interference.
• QC Batch: ICPM / 9902
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 9 of 48
15 of 55
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92251236
J15050632
Method:
Client:Duke Energy
EPA 6020
Date:June 15, 2015
Description:6020 MET ICPMS
Analyte Comments:
QC Batch: MPRP/24466
N2: The lab does not hold TNI accreditation for this parameter.
• 2015015770 (Lab ID: 92251236003)
• Antimony
• BLANK (Lab ID: 1229854)
• Antimony
• LCS (Lab ID: 1229855)
• Antimony
• MS (Lab ID: 1229856)
• Antimony
• MSD (Lab ID: 1229857)
• Antimony
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 10 of 48
16 of 55
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92251236
J15050632
Method:
Client:Duke Energy
EPA 6020A
Date:June 15, 2015
Description:6020A MET ICPMS
General Information:
3 samples were analyzed for EPA 6020A. All samples were received in acceptable condition with any exceptions noted below.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Sample Preparation:
The samples were prepared in accordance with EPA 3020 with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Internal Standards:
All internal standards were within QC limits with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
QC Batch: MPRP/54700
A matrix spike and/or matrix spike duplicate (MS/MSD) were performed on the following sample(s): 92251147009
M1: Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.
• MS (Lab ID: 1977700)
• Boron
• MSD (Lab ID: 1977701)
• Boron
QC Batch: MPRP/55041
A matrix spike and/or matrix spike duplicate (MS/MSD) were performed on the following sample(s): 92253352007
M1: Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.
• MS (Lab ID: 1989780)
• Aluminum
• MSD (Lab ID: 1989781)
• Aluminum
Additional Comments:
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 11 of 48
17 of 55
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92251236
J15050632
Method:
Client:Duke Energy
EPA 7470A
Date:June 15, 2015
Description:7470A Mercury
General Information:
3 samples were analyzed for EPA 7470A. All samples were received in acceptable condition with any exceptions noted below.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Sample Preparation:
The samples were prepared in accordance with EPA 7470A with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Additional Comments:
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 12 of 48
18 of 55
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92251236
J15050632
Method:
Client:Duke Energy
EPA 7471
Date:June 15, 2015
Description:7471 Mercury
General Information:
1 sample was analyzed for EPA 7471. All samples were received in acceptable condition with any exceptions noted below.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Sample Preparation:
The samples were prepared in accordance with EPA 7471 with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Additional Comments:
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 13 of 48
19 of 55
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92251236
J15050632
Method:
Client:Duke Energy
EPA 9045
Date:June 15, 2015
Description:9045 pH Soil
General Information:
1 sample was analyzed for EPA 9045. All samples were received in acceptable condition with any exceptions noted below.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
H1: Analysis conducted outside the EPA method holding time.
• 2015015770 (Lab ID: 92251236003)
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Duplicate Sample:
All duplicate sample results were within method acceptance criteria with any exceptions noted below.
Additional Comments:
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 14 of 48
20 of 55
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92251236
J15050632
Method:
Client:Duke Energy
EPA 300.0
Date:June 15, 2015
Description:300.0 IC Anions, SPLP
General Information:
1 sample was analyzed for EPA 300.0. All samples were received in acceptable condition with any exceptions noted below.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
QC Batch: WETA/23222
B: Analyte was detected in the associated method blank.
• BLANK for HBN 267287 [WETA/232 (Lab ID: 1479817)
• Sulfate
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Additional Comments:
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 15 of 48
21 of 55
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92251236
J15050632
Method:
Client:Duke Energy
EPA 353.2
Date:June 15, 2015
Description:353.2 Nitrogen, NO2/NO3, SPLP
General Information:
1 sample was analyzed for EPA 353.2. All samples were received in acceptable condition with any exceptions noted below.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
H1: Analysis conducted outside the EPA method holding time.
• 2015015770 (Lab ID: 92251236003)
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Additional Comments:
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 16 of 48
22 of 55
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92251236
J15050632
Method:
Client:Duke Energy
SM 4500-Cl-E
Date:June 15, 2015
Description:4500 Chloride, SPLP
General Information:
1 sample was analyzed for SM 4500-Cl-E. All samples were received in acceptable condition with any exceptions noted below.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Additional Comments:
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 17 of 48
23 of 55
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92251236
J15050632
Method:
Client:Duke Energy
EPA 9056
Date:June 15, 2015
Description:9056 IC Anions
General Information:
1 sample was analyzed for EPA 9056. All samples were received in acceptable condition with any exceptions noted below.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Additional Comments:
Analyte Comments:
QC Batch: WETA/46803
D3: Sample was diluted due to the presence of high levels of non-target analytes or other matrix interference.
• 2015015770 (Lab ID: 92251236003)
• Chloride
• Sulfate
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 18 of 48
24 of 55
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92251236
J15050632
Method:
Client:Duke Energy
EPA 9056
Date:June 15, 2015
Description:9056 IC Anions 48hr
General Information:
1 sample was analyzed for EPA 9056. All samples were received in acceptable condition with any exceptions noted below.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
H3: Sample was received or analysis requested beyond the recognized method holding time.
• 2015015770 (Lab ID: 92251236003)
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Additional Comments:
Analyte Comments:
QC Batch: WETA/46804
D3: Sample was diluted due to the presence of high levels of non-target analytes or other matrix interference.
• 2015015770 (Lab ID: 92251236003)
• Nitrate as N
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 19 of 48
25 of 55
#=NA#
PROJECT NARRATIVE
Pace Project No.:
Project:
92251236
J15050632
Method:
Client:Duke Energy
EPA 9060
Date:June 15, 2015
Description:Total Organic Carbon Quad
General Information:
1 sample was analyzed for EPA 9060. All samples were received in acceptable condition with any exceptions noted below.
Hold Time:
The samples were analyzed within the method required hold times with any exceptions noted below.
Initial Calibrations (including MS Tune as applicable):
All criteria were within method requirements with any exceptions noted below.
Continuing Calibration:
All criteria were within method requirements with any exceptions noted below.
Method Blank:
All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below.
Laboratory Control Spike:
All laboratory control spike compounds were within QC limits with any exceptions noted below.
Matrix Spikes:
All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below.
Additional Comments:
This data package has been reviewed for quality and completeness and is approved for release.
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 20 of 48
26 of 55
#=AR#
ANALYTICAL RESULTS
Pace Project No.:
Project:
92251236
J15050632
Sample:2015015768 Lab ID:92251236001 Collected:05/19/15 14:15 Received:05/22/15 14:40 Matrix:Water
Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit
Report
Analytical Method: EPA 6020A Preparation Method: EPA 30206020A MET ICPMS
Aluminum 18.1 ug/L 05/29/15 18:03 7429-90-505/28/15 21:1210.0 3.0 1
Antimony ND ug/L 05/29/15 18:03 7440-36-005/28/15 21:120.50 0.15 1
Arsenic ND ug/L 05/29/15 18:03 7440-38-205/28/15 21:120.50 0.11 1
Barium 0.70 ug/L 05/29/15 18:03 7440-39-305/28/15 21:120.30 0.081 1
Beryllium ND ug/L 05/29/15 18:03 7440-41-705/28/15 21:120.20 0.067 1
Boron ND ug/L 05/29/15 18:03 7440-42-805/28/15 21:125.0 1.1 1
Cadmium ND ug/L 05/29/15 18:03 7440-43-905/28/15 21:120.080 0.024 1
Calcium 134 ug/L 05/29/15 18:03 7440-70-205/28/15 21:1240.0 16.0 1
Chromium 1.2 ug/L 05/29/15 18:03 7440-47-305/28/15 21:120.50 0.17 1
Cobalt 3.3 ug/L 05/29/15 18:03 7440-48-405/28/15 21:120.50 0.13 1
Copper ND ug/L 05/29/15 18:03 7440-50-805/28/15 21:121.0 0.21 1
Iron 186 ug/L 05/29/15 18:03 7439-89-605/28/15 21:1250.0 13.7 1
Lead 0.070J ug/L 05/29/15 18:03 7439-92-105/28/15 21:120.10 0.046 1
Magnesium 9.9J ug/L 05/29/15 18:03 7439-95-405/28/15 21:1210.0 3.2 1
Manganese 7.0 ug/L 05/29/15 18:03 7439-96-505/28/15 21:120.50 0.24 1
Molybdenum 0.27J ug/L 05/29/15 18:03 7439-98-705/28/15 21:120.50 0.094 1
Nickel ND ug/L 05/29/15 18:03 7440-02-005/28/15 21:120.50 0.16 1
Potassium 29.3J ug/L 05/29/15 18:03 7440-09-705/28/15 21:1250.0 11.7 1
Selenium ND ug/L 05/29/15 18:03 7782-49-205/28/15 21:120.50 0.20 1
Sodium ND ug/L 05/29/15 18:03 7440-23-505/28/15 21:1250.0 16.3 1
Strontium 0.16J ug/L 05/29/15 18:03 7440-24-605/28/15 21:120.50 0.13 1
Thallium ND ug/L 05/29/15 18:03 7440-28-005/28/15 21:120.10 0.015 1
Vanadium ND ug/L 05/29/15 18:03 7440-62-205/28/15 21:121.0 0.28 1
Zinc 3.6J ug/L 05/29/15 18:03 7440-66-605/28/15 21:125.0 2.4 1
Analytical Method: EPA 7470A Preparation Method: EPA 7470A7470A Mercury
Mercury ND ug/L 06/01/15 19:57 7439-97-605/30/15 10:300.20 0.022 1
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 21 of 48
27 of 55
#=AR#
ANALYTICAL RESULTS
Pace Project No.:
Project:
92251236
J15050632
Sample:2015015769 Lab ID:92251236002 Collected:05/20/15 15:20 Received:05/22/15 14:40 Matrix:Water
Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit
Report
Analytical Method: EPA 6020A Preparation Method: EPA 30206020A MET ICPMS
Aluminum 41.7 ug/L 05/29/15 18:41 7429-90-505/28/15 21:1210.0 3.0 1
Antimony ND ug/L 05/29/15 18:41 7440-36-005/28/15 21:120.50 0.15 1
Arsenic ND ug/L 05/29/15 18:41 7440-38-205/28/15 21:120.50 0.11 1
Barium 1.5 ug/L 05/29/15 18:41 7440-39-305/28/15 21:120.30 0.081 1
Beryllium ND ug/L 05/29/15 18:41 7440-41-705/28/15 21:120.20 0.067 1
Boron 2.3J ug/L 05/29/15 18:41 7440-42-805/28/15 21:125.0 1.1 1
Cadmium ND ug/L 05/29/15 18:41 7440-43-905/28/15 21:120.080 0.024 1
Calcium 298 ug/L 05/29/15 18:41 7440-70-205/28/15 21:1240.0 16.0 1
Chromium 2.1 ug/L 05/29/15 18:41 7440-47-305/28/15 21:120.50 0.17 1
Cobalt 61.1 ug/L 05/29/15 18:41 7440-48-405/28/15 21:120.50 0.13 1
Copper 1.1 ug/L 05/29/15 18:41 7440-50-805/28/15 21:121.0 0.21 1
Iron 321 ug/L 05/29/15 18:41 7439-89-605/28/15 21:1250.0 13.7 1
Lead ND ug/L 05/29/15 18:41 7439-92-105/28/15 21:120.10 0.046 1
Magnesium 59.5 ug/L 05/29/15 18:41 7439-95-405/28/15 21:1210.0 3.2 1
Manganese 9.9 ug/L 05/29/15 18:41 7439-96-505/28/15 21:120.50 0.24 1
Molybdenum 0.32J ug/L 05/29/15 18:41 7439-98-705/28/15 21:120.50 0.094 1
Nickel 0.64 ug/L 05/29/15 18:41 7440-02-005/28/15 21:120.50 0.16 1
Potassium 90.1 ug/L 05/29/15 18:41 7440-09-705/28/15 21:1250.0 11.7 1
Selenium ND ug/L 05/29/15 18:41 7782-49-205/28/15 21:120.50 0.20 1
Sodium 182 ug/L 05/29/15 18:41 7440-23-505/28/15 21:1250.0 16.3 1
Strontium 0.80 ug/L 05/29/15 18:41 7440-24-605/28/15 21:120.50 0.13 1
Thallium ND ug/L 05/29/15 18:41 7440-28-005/28/15 21:120.10 0.015 1
Vanadium ND ug/L 05/29/15 18:41 7440-62-205/28/15 21:121.0 0.28 1
Zinc 5.2 ug/L 05/29/15 18:41 7440-66-605/28/15 21:125.0 2.4 1
Analytical Method: EPA 7470A Preparation Method: EPA 7470A7470A Mercury
Mercury ND ug/L 06/01/15 20:04 7439-97-605/30/15 10:300.20 0.022 1
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 22 of 48
28 of 55
#=AR#
ANALYTICAL RESULTS
Pace Project No.:
Project:
92251236
J15050632
Sample:2015015770 Lab ID:92251236003 Collected:05/20/15 14:15 Received:05/22/15 14:40 Matrix:Solid
Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions.
Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit
Report
Analytical Method: EPA 6010 Preparation Method: EPA 30506010 MET ICP
Aluminum 10600 mg/kg 06/04/15 01:35 7429-90-506/02/15 20:2034.0 17.0 5
Barium 56.1 mg/kg 06/04/15 01:35 7440-39-306/02/15 20:203.4 1.7 5
Beryllium 0.90 mg/kg 06/04/15 01:35 7440-41-706/02/15 20:200.34 0.17 5
Boron ND mg/kg 06/04/15 01:35 7440-42-806/02/15 20:2017.0 8.5 5
Calcium ND mg/kg 06/04/15 01:35 7440-70-206/02/15 20:2017084.9 5
Chromium 1.3J mg/kg 06/04/15 01:35 7440-47-306/02/15 20:201.7 0.85 5
Copper 9.0 mg/kg 06/04/15 01:35 7440-50-806/02/15 20:201.7 0.85 5
Iron 16900 mg/kg 06/04/15 01:35 7439-89-606/02/15 20:2013.6 6.8 5
Magnesium 4210 mg/kg 06/04/15 01:35 7439-95-406/02/15 20:2017084.9 5
Manganese 319 mg/kg 06/04/15 01:35 7439-96-506/02/15 20:201.7 0.85 5
Molybdenum ND mg/kg 06/04/15 01:35 7439-98-706/02/15 20:203.4 1.7 5
Nickel ND mg/kg 06/04/15 01:35 7440-02-006/02/15 20:201.7 0.85 5
Potassium 2980 mg/kg 06/04/15 01:35 7440-09-706/02/15 20:203401705
Selenium ND mg/kg 06/04/15 01:35 7782-49-206/02/15 20:205.1 2.5 5
Sodium ND mg/kg 06/04/15 01:35 7440-23-506/02/15 20:203401705
Strontium 3.3J mg/kg 06/04/15 01:35 7440-24-606/02/15 20:203.4 1.7 5
Zinc 27.7 mg/kg 06/04/15 01:35 7440-66-606/02/15 20:206.8 3.4 5
Analytical Method: EPA 6020 Preparation Method: EPA 30506020 MET ICPMS
Antimony ND mg/kg 06/03/15 19:56 7440-36-0 N206/02/15 20:206.8 3.4 100
Arsenic ND mg/kg 06/03/15 19:56 7440-38-206/02/15 20:206.8 3.4 100
Cadmium ND mg/kg 06/03/15 19:56 7440-43-906/02/15 20:200.81 0.41 100
Cobalt 6.6J mg/kg 06/03/15 19:56 7440-48-406/02/15 20:206.8 3.4 100
Lead ND mg/kg 06/03/15 19:56 7439-92-106/02/15 20:206.8 3.4 100
Thallium ND mg/kg 06/03/15 19:56 7440-28-006/02/15 20:206.8 3.4 100
Vanadium 28.8 mg/kg 06/03/15 19:56 7440-62-206/02/15 20:206.8 3.4 100
Analytical Method: EPA 7471 Preparation Method: EPA 74717471 Mercury
Mercury 0.021 mg/kg 06/03/15 18:18 7439-97-606/02/15 20:300.010 0.0052 1
Analytical Method: ASTM D2974-87Percent Moisture
Percent Moisture 24.6 %06/05/15 09:170.10 0.10 1
Analytical Method: EPA 90459045 pH Soil
pH at 25 Degrees C 5.9 Std. Units 06/03/15 12:00 H10.10 0.10 1
Analytical Method: EPA 300.0 Leachate Method/Date: EPA 1312; 05/28/15 04:30300.0 IC Anions, SPLP
Sulfate 3.0 mg/L 06/10/15 10:13 14808-79-8 B2.7 1.3 1
Analytical Method: EPA 353.2 Leachate Method/Date: EPA 1312; 05/28/15 04:30353.2 Nitrogen, NO2/NO3, SPLP
Nitrogen, Nitrate ND mg/L 06/09/15 17:53 H10.27 0.27 1
Analytical Method: SM 4500-Cl-E Leachate Method/Date: EPA 1312; 05/28/15 04:304500 Chloride, SPLP
Chloride ND mg/L 06/06/15 07:37 16887-00-66.6 3.3 1
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 23 of 48
29 of 55
#=AR#
ANALYTICAL RESULTS
Pace Project No.:
Project:
92251236
J15050632
Sample:2015015770 Lab ID:92251236003 Collected:05/20/15 14:15 Received:05/22/15 14:40 Matrix:Solid
Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions.
Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit
Report
Analytical Method: EPA 90569056 IC Anions
Chloride ND mg/kg 05/29/15 15:01 16887-00-6 D33381695
Sulfate ND mg/kg 05/29/15 15:01 14808-79-8 D33381695
Analytical Method: EPA 90569056 IC Anions 48hr
Nitrate as N ND mg/kg 05/29/15 15:01 14797-55-8 D3,H333.8 16.9 5
Analytical Method: EPA 9060Total Organic Carbon Quad
Total Organic Carbon ND mg/kg 06/12/15 09:11 7440-44-07893951
Total Organic Carbon ND mg/kg 06/12/15 09:17 7440-44-07953981
Total Organic Carbon ND mg/kg 06/12/15 09:22 7440-44-08014001
Total Organic Carbon ND mg/kg 06/12/15 09:28 7440-44-07923961
Mean Total Organic Carbon ND mg/kg 06/12/15 09:11 7440-44-07943971
Surrogates
RSD%1.6 %06/12/15 09:111
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 24 of 48
30 of 55
#=AR#
ANALYTICAL RESULTS
Pace Project No.:
Project:
92251236
J15050632
Sample:2015015770 SPLP Lab ID:92251236004 Collected:05/20/15 14:15 Received:05/22/15 14:40 Matrix:Water
Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit
Report
Analytical Method: EPA 6020A Preparation Method: EPA 30206020A MET ICPMS
Aluminum 268 ug/L 06/10/15 16:09 7429-90-506/10/15 11:3210.0 3.0 1
Antimony ND ug/L 06/10/15 16:09 7440-36-006/10/15 11:320.50 0.15 1
Arsenic 0.17J ug/L 06/10/15 16:09 7440-38-206/10/15 11:320.50 0.11 1
Barium 80.2 ug/L 06/10/15 16:09 7440-39-306/10/15 11:320.30 0.081 1
Beryllium ND ug/L 06/10/15 16:09 7440-41-706/10/15 11:320.20 0.067 1
Boron 85.6 ug/L 06/10/15 16:09 7440-42-806/10/15 11:325.0 1.1 1
Cadmium ND ug/L 06/10/15 16:09 7440-43-906/10/15 11:320.080 0.024 1
Calcium 170 ug/L 06/10/15 16:09 7440-70-206/10/15 11:3240.0 16.0 1
Chromium 0.55 ug/L 06/10/15 16:09 7440-47-306/10/15 11:320.50 0.17 1
Cobalt 0.15J ug/L 06/10/15 16:09 7440-48-406/10/15 11:320.50 0.13 1
Copper 0.54J ug/L 06/10/15 16:09 7440-50-806/10/15 11:321.0 0.21 1
Iron 95.1 ug/L 06/10/15 16:09 7439-89-606/10/15 11:3250.0 13.7 1
Lead 0.072J ug/L 06/10/15 16:09 7439-92-106/10/15 11:320.10 0.046 1
Magnesium 40.8 ug/L 06/10/15 16:09 7439-95-406/10/15 11:3210.0 3.2 1
Manganese 4.8 ug/L 06/10/15 16:09 7439-96-506/10/15 11:320.50 0.24 1
Molybdenum ND ug/L 06/10/15 16:09 7439-98-706/10/15 11:320.50 0.094 1
Nickel 0.18J ug/L 06/10/15 16:09 7440-02-006/10/15 11:320.50 0.16 1
Potassium 102 ug/L 06/10/15 16:09 7440-09-706/10/15 11:3250.0 11.7 1
Selenium ND ug/L 06/10/15 16:09 7782-49-206/10/15 11:320.50 0.20 1
Sodium 1870 ug/L 06/10/15 16:09 7440-23-506/10/15 11:3250.0 16.3 1
Strontium 3.2 ug/L 06/10/15 16:09 7440-24-606/10/15 11:320.50 0.13 1
Thallium ND ug/L 06/10/15 16:09 7440-28-006/10/15 11:320.10 0.015 1
Vanadium 0.61J ug/L 06/10/15 16:09 7440-62-206/10/15 11:321.0 0.28 1
Zinc 56.7 ug/L 06/10/15 16:09 7440-66-606/10/15 11:325.0 2.4 1
Analytical Method: EPA 7470A Preparation Method: EPA 7470A7470A Mercury
Mercury ND ug/L 06/10/15 15:00 7439-97-606/10/15 10:300.20 0.022 1
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 25 of 48
31 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
MERP/13678
EPA 7470A
EPA 7470A
7470A Mercury Water
Associated Lab Samples:92251236001, 92251236002
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1977493
Associated Lab Samples:92251236001, 92251236002
Matrix:Water
Analyzed
Mercury ug/L ND 0.20 06/01/15 19:52
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1977494LABORATORY CONTROL SAMPLE:
LCSSpike
Mercury ug/L 4.85 96 80-120
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1977495MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92251236001
1977496
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Mercury ug/L 5 100 80-12099 1 205ND5.0 5.0
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 26 of 48
32 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
MERP/13814
EPA 7470A
EPA 7470A
7470A Mercury Water
Associated Lab Samples:92251236004
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1989756
Associated Lab Samples:92251236004
Matrix:Water
Analyzed
Mercury ug/L ND 0.20 06/10/15 14:06
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1989757LABORATORY CONTROL SAMPLE:
LCSSpike
Mercury ug/L 5.05 100 80-120
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1989758MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92253195001
1989759
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Mercury ug/L 5 110 80-120106 4 205ND5.5 5.3
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 27 of 48
33 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
MERP/5803
EPA 7471
EPA 7471
7471 Mercury
Associated Lab Samples:92251236003
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1229879
Associated Lab Samples:92251236003
Matrix:Solid
Analyzed
Mercury mg/kg ND 0.0080 06/03/15 17:24
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1229880LABORATORY CONTROL SAMPLE:
LCSSpike
Mercury mg/kg 0.081.082 98 80-120
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1229881MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92251157007
1229882
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Mercury mg/kg .142 101 80-120102 3 20.144ND 0.15 0.15
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 28 of 48
34 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
MPRP/24465
EPA 3050
EPA 6010
6010 MET Solid
Associated Lab Samples:92251236003
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1229847
Associated Lab Samples:92251236003
Matrix:Solid
Analyzed
Aluminum mg/kg ND 5.0 06/03/15 23:37
Barium mg/kg ND 0.50 06/03/15 23:37
Beryllium mg/kg ND 0.050 06/03/15 23:37
Boron mg/kg ND 2.5 06/03/15 23:37
Calcium mg/kg ND 25.0 06/03/15 23:37
Chromium mg/kg ND 0.25 06/03/15 23:37
Copper mg/kg ND 0.25 06/03/15 23:37
Iron mg/kg ND 2.0 06/03/15 23:37
Magnesium mg/kg ND 25.0 06/03/15 23:37
Manganese mg/kg ND 0.25 06/03/15 23:37
Molybdenum mg/kg ND 0.50 06/03/15 23:37
Nickel mg/kg ND 0.25 06/03/15 23:37
Potassium mg/kg ND 49.9 06/03/15 23:37
Selenium mg/kg ND 0.75 06/03/15 23:37
Sodium mg/kg ND 49.9 06/03/15 23:37
Strontium mg/kg ND 0.50 06/03/15 23:37
Zinc mg/kg ND 1.0 06/03/15 23:37
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1229848LABORATORY CONTROL SAMPLE:
LCSSpike
Aluminum mg/kg 112127 88 80-120
Barium mg/kg 11.412.7 90 80-120
Beryllium mg/kg 1.11.3 89 80-120
Boron mg/kg 113127 89 80-120
Calcium mg/kg 571635 90 80-120
Chromium mg/kg 11.312.7 89 80-120
Copper mg/kg 11.112.7 88 80-120
Iron mg/kg 111127 87 80-120
Magnesium mg/kg 567635 89 80-120
Manganese mg/kg 11.412.7 89 80-120
Molybdenum mg/kg 11.112.7 87 80-120
Nickel mg/kg 11.412.7 89 80-120
Potassium mg/kg 557635 88 80-120
Selenium mg/kg 10.612.7 84 80-120
Sodium mg/kg 572635 90 80-120
Strontium mg/kg 11.112.7 87 80-120
Zinc mg/kg 56.063.5 88 80-120
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 29 of 48
35 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1229849MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92251157007
1229850
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Aluminum mg/kg M123114975-125341 17 20228195022902720
Barium mg/kg 23.1 79 75-125112 12 2022.838.2 56.5 63.7
Beryllium mg/kg 2.31 84 75-12595 10 202.310.43J 2.4 2.6
Boron mg/kg 231 85 75-12593 8 20228ND202219
Calcium mg/kg 1150 85 75-125116 16 20114095719402280
Chromium mg/kg 23.1 83 75-12597 12 2022.84.3 23.4 26.3
Copper mg/kg 23.1 84 75-12596 10 2022.84.8 24.2 26.7
Iron mg/kg M1231-176 75-12515 17 20228277023602800
Magnesium mg/kg 1150 87 75-12599 11 201140160J11601290
Manganese mg/kg M123.1 74 75-12594 13 2022.815.6 32.6 37.1
Molybdenum mg/kg 23.1 82 75-12592 8 2022.84.9 23.8 25.9
Nickel mg/kg 23.1 87 75-125100 11 2022.84.4 24.6 27.3
Potassium mg/kg 1150 87 75-12598 9 201140ND11801280
Selenium mg/kg 23.1 80 75-12590 10 2022.8ND 18.4 20.5
Sodium mg/kg 1150 92 75-12595 2 201140ND11401160
Strontium mg/kg 23.1 79 75-125117 16 2022.829.7 48.0 56.4
Zinc mg/kg 115 85 75-12595 9 20114ND101111
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 30 of 48
36 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
MPRP/24466
EPA 3050
EPA 6020
6020 MET SOLID
Associated Lab Samples:92251236003
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1229854
Associated Lab Samples:92251236003
Matrix:Solid
Analyzed
Antimony mg/kg ND 0.051 N206/03/15 18:24
Arsenic mg/kg ND 0.051 06/03/15 18:24
Cadmium mg/kg ND 0.0061 06/03/15 18:24
Cobalt mg/kg ND 0.051 06/03/15 18:24
Lead mg/kg ND 0.051 06/03/15 18:24
Thallium mg/kg ND 0.051 06/03/15 18:24
Vanadium mg/kg ND 0.051 06/03/15 18:24
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1229855LABORATORY CONTROL SAMPLE:
LCSSpike
Antimony mg/kg 2.4 N22.5 93 80-120
Arsenic mg/kg 2.42.5 95 80-120
Cadmium mg/kg 0.22.25 87 80-120
Cobalt mg/kg 2.42.5 94 80-120
Lead mg/kg 2.32.5 90 80-120
Thallium mg/kg 2.42.5 92 80-120
Vanadium mg/kg 2.42.5 93 80-120
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1229856MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92251157007
1229857
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Antimony mg/kg N24.45 88 75-12576 204.63ND ND ND
Arsenic mg/kg M64.45 73 75-12582 3 204.6313.2 16.5 17.0
Cadmium mg/kg .445 102 75-125100 20.463ND ND ND
Cobalt mg/kg 4.45 99 75-12582 204.63ND 6.2J 5.6J
Lead mg/kg 4.45 93 75-12582 204.63ND 5.2J 4.8J
Thallium mg/kg M64.45 64 75-12563 204.63ND ND ND
Vanadium mg/kg 4.45 114 75-12576 204.634.8J 10 8.4J
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 31 of 48
37 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
MPRP/54700
EPA 3020
EPA 6020A
6020A Water UPD4
Associated Lab Samples:92251236001, 92251236002
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1977698
Associated Lab Samples:92251236001, 92251236002
Matrix:Water
Analyzed
Aluminum ug/L ND 10.0 05/29/15 16:47
Antimony ug/L ND 0.50 05/29/15 16:47
Arsenic ug/L ND 0.50 05/29/15 16:47
Barium ug/L ND 0.30 05/29/15 16:47
Beryllium ug/L ND 0.20 05/29/15 16:47
Boron ug/L ND 5.0 05/29/15 16:47
Cadmium ug/L ND 0.080 05/29/15 16:47
Calcium ug/L ND 40.0 05/29/15 16:47
Chromium ug/L ND 0.50 05/29/15 16:47
Cobalt ug/L ND 0.50 05/29/15 16:47
Copper ug/L ND 1.0 05/29/15 16:47
Iron ug/L ND 50.0 05/29/15 16:47
Lead ug/L ND 0.10 05/29/15 16:47
Magnesium ug/L ND 10.0 05/29/15 16:47
Manganese ug/L ND 0.50 05/29/15 16:47
Molybdenum ug/L ND 0.50 05/29/15 16:47
Nickel ug/L ND 0.50 05/29/15 16:47
Potassium ug/L ND 50.0 05/29/15 16:47
Selenium ug/L ND 0.50 05/29/15 16:47
Sodium ug/L ND 50.0 05/29/15 16:47
Strontium ug/L ND 0.50 05/29/15 16:47
Thallium ug/L ND 0.10 05/29/15 16:47
Vanadium ug/L ND 1.0 05/29/15 16:47
Zinc ug/L ND 5.0 05/29/15 16:47
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1977699LABORATORY CONTROL SAMPLE:
LCSSpike
Aluminum ug/L 85.480 107 80-120
Antimony ug/L 78.980 99 80-120
Arsenic ug/L 79.880 100 80-120
Barium ug/L 79.280 99 80-120
Beryllium ug/L 77.980 97 80-120
Boron ug/L 81.480 102 80-120
Cadmium ug/L 81.280 102 80-120
Calcium ug/L 10201000 102 80-120
Chromium ug/L 81.980 102 80-120
Cobalt ug/L 79.180 99 80-120
Copper ug/L 82.480 103 80-120
Iron ug/L 10201000 102 80-120
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 32 of 48
38 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1977699LABORATORY CONTROL SAMPLE:
LCSSpike
Lead ug/L 77.480 97 80-120
Magnesium ug/L 10301000 103 80-120
Manganese ug/L 83.180 104 80-120
Molybdenum ug/L 79.880 100 80-120
Nickel ug/L 81.480 102 80-120
Potassium ug/L 10101000 101 80-120
Selenium ug/L 80.380 100 80-120
Sodium ug/L 9751000 97 80-120
Strontium ug/L 79.580 99 80-120
Thallium ug/L 79.080 99 80-120
Vanadium ug/L 81.780 102 80-120
Zinc ug/L 83.080 104 80-120
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1977700MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92251147009
1977701
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Aluminum ug/L 80 109 75-125112 1 2080230317320
Antimony ug/L 80 100 75-125101 0 2080ND80.4 80.8
Arsenic ug/L 80 102 75-125102 0 2080ND81.4 81.4
Barium ug/L 80 100 75-125101 0 20803.5 83.5 83.9
Beryllium ug/L 80 101 75-12599 2 2080ND80.8 79.0
Boron ug/L M1805675-12556 0 208039.5 84.1 84.4
Cadmium ug/L 80 104 75-125103 1 2080ND83.0 82.3
Calcium ug/L 1000 104 75-125102 2 20100022912701250
Chromium ug/L 80 102 75-125104 2 2080ND82.0 83.4
Cobalt ug/L 80 100 75-125101 0 2080ND80.4 80.6
Copper ug/L 80 104 75-125105 0 20802.1 85.6 85.8
Iron ug/L 1000 102 75-125104 1 20100013811601170
Lead ug/L 80 100 75-12599 0 20800.37 80.3 80.0
Magnesium ug/L 1000 105 75-125105 0 20100020.5 1070 1070
Manganese ug/L 80 105 75-125105 0 208015.1 98.9 99.4
Molybdenum ug/L 80 101 75-125102 1 2080ND80.9 81.7
Nickel ug/L 80 101 75-125103 2 2080ND81.5 82.9
Potassium ug/L 1000 101 75-125102 1 20100051.5 1070 1070
Selenium ug/L 80 103 75-12598 5 2080ND82.2 78.4
Sodium ug/L 1000 98 75-12596 1 201000ND10201000
Strontium ug/L 80 101 75-125101 0 20802.2 82.7 82.9
Thallium ug/L 80 105 75-125105 0 2080ND83.8 83.8
Vanadium ug/L 80 103 75-125104 1 2080ND82.6 83.3
Zinc ug/L 80 100 75-125106 5 2080ND84.0 88.6
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 33 of 48
39 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
MPRP/55041
EPA 3020
EPA 6020A
6020A Water UPD4
Associated Lab Samples:92251236004
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1989137
Associated Lab Samples:92251236004
Matrix:Water
Analyzed
Aluminum ug/L ND 10.0 06/10/15 15:28
Antimony ug/L ND 0.50 06/10/15 15:28
Arsenic ug/L ND 0.50 06/10/15 15:28
Barium ug/L ND 0.30 06/10/15 15:28
Beryllium ug/L ND 0.20 06/10/15 15:28
Boron ug/L ND 5.0 06/10/15 15:28
Cadmium ug/L ND 0.080 06/10/15 15:28
Calcium ug/L ND 40.0 06/10/15 15:28
Chromium ug/L ND 0.50 06/10/15 15:28
Cobalt ug/L ND 0.50 06/10/15 15:28
Copper ug/L ND 1.0 06/10/15 15:28
Iron ug/L ND 50.0 06/10/15 15:28
Lead ug/L ND 0.10 06/10/15 15:28
Magnesium ug/L ND 10.0 06/10/15 15:28
Manganese ug/L ND 0.50 06/10/15 15:28
Molybdenum ug/L 0.13J 0.50 06/10/15 15:28
Nickel ug/L ND 0.50 06/10/15 15:28
Potassium ug/L ND 50.0 06/10/15 15:28
Selenium ug/L ND 0.50 06/10/15 15:28
Sodium ug/L ND 50.0 06/10/15 15:28
Strontium ug/L ND 0.50 06/10/15 15:28
Thallium ug/L ND 0.10 06/10/15 15:28
Vanadium ug/L ND 1.0 06/10/15 15:28
Zinc ug/L ND 5.0 06/10/15 15:28
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1989138LABORATORY CONTROL SAMPLE:
LCSSpike
Aluminum ug/L 76.980 96 80-120
Antimony ug/L 77.380 97 80-120
Arsenic ug/L 78.280 98 80-120
Barium ug/L 81.980 102 80-120
Beryllium ug/L 81.780 102 80-120
Boron ug/L 79.680 99 80-120
Cadmium ug/L 79.180 99 80-120
Calcium ug/L 9851000 98 80-120
Chromium ug/L 79.980 100 80-120
Cobalt ug/L 84.780 106 80-120
Copper ug/L 81.580 102 80-120
Iron ug/L 10401000 104 80-120
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 34 of 48
40 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1989138LABORATORY CONTROL SAMPLE:
LCSSpike
Lead ug/L 79.980 100 80-120
Magnesium ug/L 9891000 99 80-120
Manganese ug/L 75.880 95 80-120
Molybdenum ug/L 77.780 97 80-120
Nickel ug/L 79.380 99 80-120
Potassium ug/L 9321000 93 80-120
Selenium ug/L 78.980 99 80-120
Sodium ug/L 10301000 103 80-120
Strontium ug/L 76.180 95 80-120
Thallium ug/L 84.780 106 80-120
Vanadium ug/L 77.680 97 80-120
Zinc ug/L 81.380 102 80-120
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1989780MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92253352007
1989781
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Aluminum ug/L M18013675-125135 1 208037.2 146 145
Antimony ug/L 80 98 75-12598 0 2080ND78.6 78.8
Arsenic ug/L 80 102 75-125102 0 2080ND81.5 81.7
Barium ug/L 80 96 75-12598 2 20800.67 77.2 78.9
Beryllium ug/L 80 105 75-125104 1 2080ND83.8 82.9
Boron ug/L 80 94 75-12599 5 20801.4J 76.5 80.3
Cadmium ug/L 80 99 75-125101 3 2080ND78.8 81.1
Calcium ug/L 1000 94 75-125104 8 20100016211001200
Chromium ug/L 80 98 75-125101 3 20800.33J 78.7 81.2
Cobalt ug/L 80 99 75-125100 1 2080ND79.0 79.9
Copper ug/L 80 102 75-125103 2 20800.95J 82.2 83.6
Iron ug/L 1000 107 75-125111 3 20100061.6 1130 1170
Lead ug/L 80 98 75-125100 2 20800.10 78.4 79.9
Magnesium ug/L 1000 98 75-125100 2 20100028.0 1010 1030
Manganese ug/L 80 93 75-12597 4 20801.9 76.6 79.4
Molybdenum ug/L 80 98 75-12599 0 20800.095J 78.6 78.9
Nickel ug/L 80 100 75-125100 1 20800.17J 79.8 80.3
Potassium ug/L 1000 99 75-125100 1 20100022.2J 1010 1030
Selenium ug/L 80 104 75-125103 1 2080ND83.2 82.2
Sodium ug/L 1000 89 75-12591 2 20100048.7J 940 955
Strontium ug/L 80 96 75-12597 2 20800.94 77.4 78.9
Thallium ug/L 80 105 75-125107 1 2080ND84.1 85.3
Vanadium ug/L 80 95 75-12598 3 2080ND76.5 78.9
Zinc ug/L 80 102 75-125101 1 20808.1 89.3 88.9
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 35 of 48
41 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
PMST/3618
ASTM D2974-87
ASTM D2974-87
Dry Weight/Percent Moisture
Associated Lab Samples:92251236003
Parameter Units
Dup
Result
Max
RPD QualifiersRPDResult
92250709001
1233279SAMPLE DUPLICATE:
Percent Moisture %15.4 4 1016.0
Parameter Units
Dup
Result
Max
RPD QualifiersRPDResult
92250709013
1233280SAMPLE DUPLICATE:
Percent Moisture %26.5 4 1027.6
Parameter Units
Dup
Result
Max
RPD QualifiersRPDResult
35190598001
1233281SAMPLE DUPLICATE:
Percent Moisture %23.7 3 10
Parameter Units
Dup
Result
Max
RPD QualifiersRPDResult
35190619004
1233282SAMPLE DUPLICATE:
Percent Moisture %4.1 2 104.2
Parameter Units
Dup
Result
Max
RPD QualifiersRPDResult
35191337002
1233283SAMPLE DUPLICATE:
Percent Moisture %4.4 D615103.8
Parameter Units
Dup
Result
Max
RPD QualifiersRPDResult
35191350005
1233284SAMPLE DUPLICATE:
Percent Moisture %18.4 D6271024.2
Parameter Units
Dup
Result
Max
RPD QualifiersRPDResult
35191350014
1233285SAMPLE DUPLICATE:
Percent Moisture %13.3 9 1012.1
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 36 of 48
42 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
WET/37801
EPA 9045
EPA 9045
9045 pH
Associated Lab Samples:92251236003
Parameter Units
Dup
Result
Max
RPD QualifiersRPDResult
92251251005
1472050SAMPLE DUPLICATE:
pH at 25 Degrees C Std. Units 6.9 H32106.8
Parameter Units
Dup
Result
Max
RPD QualifiersRPDResult
92251242018
1472051SAMPLE DUPLICATE:
pH at 25 Degrees C Std. Units 5.5 H31105.5
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 37 of 48
43 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
WETA/23222
EPA 300.0
EPA 300.0
300.0 IC Anions
Associated Lab Samples:92251236003
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1479817
Associated Lab Samples:92251236003
Matrix:Water
Analyzed
Sulfate mg/L 3.2 2.0 06/09/15 22:29
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1479818LABORATORY CONTROL SAMPLE:
LCSSpike
Sulfate mg/L 19.120 96 90-110
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1479819MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92251132016
1479820
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Sulfate mg/L 31.9 96 93 231.98.0 38.7 37.8
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 38 of 48
44 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
WETA/23223
EPA 353.2
EPA 353.2
353.2 Nitrate + Nitrite, Unpres.
Associated Lab Samples:92251236003
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1480060
Associated Lab Samples:92251236003
Matrix:Water
Analyzed
Nitrogen, Nitrate mg/L 0.18 0.020 Z206/09/15 17:32
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1480061LABORATORY CONTROL SAMPLE:
LCSSpike
Nitrogen, Nitrate mg/L 2.42.5 96 90-110
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1480062MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92250709003
1480063
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Nitrogen, Nitrate mg/L H13.6 93 90-11093 0 103.6ND 3.6 3.6
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1480064MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92250709005
1480065
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Nitrogen, Nitrate mg/L H13.5 92 90-11092 0 103.5ND 3.4 3.4
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 39 of 48
45 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
WETA/23153
SM 4500-Cl-E
SM 4500-Cl-E
4500 Chloride
Associated Lab Samples:92251236003
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1474736
Associated Lab Samples:92251236003
Matrix:Water
Analyzed
Chloride mg/L ND 1.0 06/06/15 07:23
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1474737LABORATORY CONTROL SAMPLE:
LCSSpike
Chloride mg/L 19.920 100 90-110
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1474738MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92250515002
1474739
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Chloride mg/L 23.8 92 90-11092 0 1023.8ND 24.3 24.2
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1474762MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92250709003
1474763
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Chloride mg/L 28.8 91 90-11090 1 1028.8ND 27.1 26.9
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 40 of 48
46 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
WETA/46803
EPA 9056
EPA 9056
9056 IC Anions
Associated Lab Samples:92251236003
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1226976
Associated Lab Samples:
Matrix:Solid
Analyzed
Chloride mg/kg ND 49.5 05/29/15 06:56
Sulfate mg/kg ND 49.5 05/29/15 06:56
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1226977LABORATORY CONTROL SAMPLE:
LCSSpike
Chloride mg/kg 489499 98 80-120
Sulfate mg/kg 478499 96 80-120
Parameter Units
MS
Result
% Rec
Limits Qualifiers% RecConc.
1226979MATRIX SPIKE SAMPLE:
MSSpike
Result
92251251005
Chloride mg/kg 474 H15269080-120ND
Sulfate mg/kg 508 H15268480-120ND
Parameter Units
Dup
Result
Max
RPD QualifiersRPDResult
92251251005
1226978SAMPLE DUPLICATE:
Chloride mg/kg ND H120ND
Sulfate mg/kg ND H120ND
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 41 of 48
47 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
WETA/46804
EPA 9056
EPA 9056
9056 IC Anions
Associated Lab Samples:92251236003
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1226986
Associated Lab Samples:
Matrix:Solid
Analyzed
Nitrate as N mg/kg ND 5.0 05/29/15 06:56
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1226987LABORATORY CONTROL SAMPLE:
LCSSpike
Nitrate as N mg/kg 48.449.9 97 80-120
Parameter Units
MS
Result
% Rec
Limits Qualifiers% RecConc.
1226989MATRIX SPIKE SAMPLE:
MSSpike
Result
92251251005
Nitrate as N mg/kg 48.1 H352.6 92 80-120ND
Parameter Units
Dup
Result
Max
RPD QualifiersRPDResult
92251251005
1226988SAMPLE DUPLICATE:
Nitrate as N mg/kg ND H320ND
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 42 of 48
48 of 55
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92251236
J15050632
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
WETA/28987
EPA 9060
EPA 9060
9060 TOC Average
Associated Lab Samples:92251236003
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:1173951
Associated Lab Samples:
Matrix:Solid
Analyzed
Mean Total Organic Carbon mg/kg ND 600 06/12/15 08:04
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
1173952LABORATORY CONTROL SAMPLE:
LCSSpike
Mean Total Organic Carbon mg/kg 105000120000 87 80-120
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1173953MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92251236003
1173954
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Mean Total Organic Carbon mg/kg 7920 83 50-15095 12 307920ND68907800
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
1173955MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92251877001
1173956
MSD
Result
MSD
% Rec RPD RPD
Max
MSDMS
Spike
Conc.
Mean Total Organic Carbon mg/kg 7830 88 50-15088 1 307800772J76607620
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 43 of 48
49 of 55
#=QL#
QUALIFIERS
Pace Project No.:
Project:
92251236
J15050632
DEFINITIONS
DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot.
ND - Not Detected at or above adjusted reporting limit.
J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit.
MDL - Adjusted Method Detection Limit.
PQL - Practical Quantitation Limit.
RL - Reporting Limit.
S - Surrogate
1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is
a combined concentration.
Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values.
LCS(D) - Laboratory Control Sample (Duplicate)
MS(D) - Matrix Spike (Duplicate)
DUP - Sample Duplicate
RPD - Relative Percent Difference
NC - Not Calculable.
SG - Silica Gel - Clean-Up
U - Indicates the compound was analyzed for, but not detected.
Acid preservation may not be appropriate for 2 Chloroethylvinyl ether, Styrene, and Vinyl chloride.
A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA
Method 8260.
N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for
each analyte is a combined concentration.
Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes.
TNI - The NELAC Institute.
LABORATORIES
Pace Analytical Services - AshevillePASI-A
Pace Analytical Services - Green BayPASI-G
Pace Analytical Services - MinneapolisPASI-M
Pace Analytical Services - Ormond BeachPASI-O
BATCH QUALIFIERS
Batch: ICP/14943
Sample was diluted due to the presence of high levels of non-target analytes or other matrix interference.[1]
Batch: ICPM/9902
Sample was diluted due to the presence of high levels of non-target analytes or other matrix interference.[1]
ANALYTE QUALIFIERS
Analyte was detected in the associated method blank.B
Sample was diluted due to the presence of high levels of non-target analytes or other matrix interference.D3
The relative percent difference (RPD) between the sample and sample duplicate exceeded laboratory control limits.D6
Analysis conducted outside the EPA method holding time.H1
Sample was received or analysis requested beyond the recognized method holding time.H3
Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.M1
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 44 of 48
50 of 55
#=QL#
QUALIFIERS
Pace Project No.:
Project:
92251236
J15050632
ANALYTE QUALIFIERS
Matrix spike and Matrix spike duplicate recovery not evaluated against control limits due to sample dilution.M6
The lab does not hold TNI accreditation for this parameter.N2
Analyte present in the associated method blank above the detection limit.Z2
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 45 of 48
51 of 55
#=CR#
QUALITY CONTROL DATA CROSS REFERENCE TABLE
Pace Project No.:
Project:
92251236
J15050632
Lab ID Sample ID QC Batch Method QC Batch Analytical Method
Analytical
Batch
92251236003 MPRP/24465 ICP/149432015015770EPA 3050 EPA 6010
92251236003 MPRP/24466 ICPM/99022015015770EPA 3050 EPA 6020
92251236001 MPRP/54700 ICPM/245072015015768EPA 3020 EPA 6020A
92251236002 MPRP/54700 ICPM/245072015015769EPA 3020 EPA 6020A
92251236004 MPRP/55041 ICPM/247382015015770 SPLP EPA 3020 EPA 6020A
92251236001 MERP/13678 MERC/159262015015768EPA 7470A EPA 7470A
92251236002 MERP/13678 MERC/159262015015769EPA 7470A EPA 7470A
92251236004 MERP/13814 MERC/160862015015770 SPLP EPA 7470A EPA 7470A
92251236003 MERP/5803 MERC/57902015015770EPA 7471 EPA 7471
92251236003 PMST/36182015015770ASTM D2974-87
92251236003 WET/378012015015770EPA 9045
92251236003 WETA/232222015015770EPA 300.0
92251236003 WETA/232232015015770EPA 353.2
92251236003 WETA/231532015015770SM 4500-Cl-E
92251236003 WETA/468032015015770EPA 9056
92251236003 WETA/468042015015770EPA 9056
92251236003 WETA/289872015015770EPA 9060
92251236003 WETA/289882015015770EPA 9060
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc..Date: 06/15/2015 01:39 PM
Pace Analytical Services, Inc.
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 46 of 48
52 of 55
Page 47 of 48
53 of 55
Page 48 of 48
54 of 55
55 of 55