HomeMy WebLinkAboutNC0045144_Compliance Evaluation Inspection Report_20171016Water Resources ENVIRONMENTAL OUAL#TY October 16, 2017 Jay Fuller Alamance -Burlington School System 1732 Vaughn Road Burlington, NC 27217 Subject: Compliance Evaluation Inspection Report NPDES Permit NCO045144 Western Alamance High School WWTP, Alamance County Dear Mr. Fuller: ROY COOPER MICHAEL S. RECAN spavary 5, JAY ZIMMERMAN Dftvtor OCT 2 7 2017 Water Quality Permitting Section On October 5, 2017, Paul DiMatteo of the Division of Water Resources ("Division"), Winston-Salem Regional Office conducted a Compliance Evaluation Inspection of the above referenced wastewater treatment system. Matthew Smith, Operator in Responsible Charge (ORC), was present for the inspection. An inspection summary follows and an inspection report is attached for your records. Site Review 1. Permit The current permit became effective on July 1, 2016 and expires on April 30, 2021. A copy of the current permit was available for review. Permitted components include a septic tank, sand filter, UV disinfection and backup chlorination. 2. Facility Site Review The facility was as described in the permit. Access to the site is restricted by a chain link fence. Wastewater is dosed to the sand filter with a siphon mechanism, not a pump. A high water alarm is not present in the dosing tank. 3. Operation and Maintenance The operator or a properly designated backup visits the site as required. Visitation logs were current and available during the inspection. It was noted that our list of designated operators is not up to date. Please complete and submit the enclosed operator designation form so that our database can be updated. State of North Carolina I Environmental Quality I Water Resources 450 West Hanes Mill Road, Suite 300, Winston-Salem, NC 27105 Previous inspections noted that the sand bed appeared increasingly worse with time. While the bed's operation could not be evaluated during the inspection, it should be maintained to ensure proper operation.- Mr. Smith said that .the bed is occasionally raked by maintenance staff. 4. Flow Measurement Flow is estimated using data from the potable water meter. 5. Effluent/Receiving Waters The effluent is discharged into the Haw River in the Cape Fear River Basin. The outfall was visible from the bridge over the Haw River on Gerringer Mill Road. There was a slight discharge during the inspection. The stream did not appear to be negatively impacted. Documentation Review 6. Records/Reports Discharge Monitoring Reports (DMRs) and lab data are maintained according to the permit. DMRs include all permit parameters. Copies of DMRs, operator visitation logs, lab reports and Chain -of - Custody forms were available for review during the inspection. 7. Self -Monitoring Program A review of DMRs from January, 2016 through July, 2017 showed no violations, and a comparison of submitted DMR data and field records showed no errors or concerns. 8. Laboratory All parameters are analyzed by Research & Analytical Laboratories, Certification #34. ORC measures pH and temperature at the facility. All other samples are collected by the ORC and analyzed at the main laboratory. pH meter pre -run calibration and sampling procedures appeared acceptable. However, Mr. Smith said that a post analysis calibration check was not performed. Please refer to the enclosed technical assistance document, which states that "When performing analyses away from the certified laboratory's primary location, a post analysis calibration verification using the check standard buffer must be analyzed at the end of the run." Temperature is measured using the digital thermometer on the Dissolved Oxygen meter. It was .noted that the last calibration of this meter was performed on October 6, 2016. Mr. Smith said he would have the main laboratory perform the calibration within the coming days. 9. Sludge Handling Disposal Mr. Smith said that the septic tank is usually emptied twice per year. Records of the removal were available on site. The tank was pumped on 8/2017, 10/2016, 8/2016, and 2/2015 by Jenkins Waste Management. State of North Carolina I Environmental Quality I Water Resources 450 West Hanes Mill Road, Suite 300, Winston-Salem, NC 27105 If you should have any questions, please do not hesitate to contact Paul DiMatteo at (336) 776-9691 or our office at (336) 776-9800. Sincerely, t_/Sherri V. Knight, P.E., Regional Supervisor Water Quality Regional Operations Section Winston-Salem Regional Office Division of Water Resources, NCDEQ Enclosures — pH TA Document, Inspection Report and Summary CC: Matthew Smith — by email WQS Winston-Salem Regional Office - Enforcement File NPDES Compliance/Enforcement Unit - Enforcement File Central Files State of North Carolina I Environmental Quality I Water Resources 450 West Hanes Mill Road, Suite 300, Winston-Salem, NC 27105 United States Environmental Protection Agency Fort Approved EPA Washington, D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires s-31-98 Section A National Data System Coding (I a, PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 E 2 IS 1 3 I NCO045144 I11 12 17/10/05 17 18 I S I 19 l c I 201 I 211111 1 1 1 1 1 1 II I LI I l 1 l l l l l l I I I I I I I I l 1 l 11 1 1 1 1 1.166 Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA ----- Reserved -- 67 70 IJ 711 itI 72 �, 731 I 174 75 80 JData L_J I I I Section B Facility Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also Include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09 30AM 17/10/05 16107/01 Western Alamance High School 1731 NC Hwy B7 N Exit Time/Date Permit Expiration Date Elon College NC 27244 11 45AM 17/10/05 21104130 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Matthew P Smith/ORC/336-414-8274/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Jay Fuller,1732 Vaughn Rd Burlington NC 27217//336-570-6482/3365706485 No Section C Areas Evaluated During Inspection (Check only those areas evaluated) ' Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Laboratory Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Paul DlMatteo WSRO WQ//336-776-9691/ -y2-.c " j)A00 /b/107_ Signature of M nagement Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete Page# NPDES yr/mo/day Inspection Type (Cont.) -3 1 - - - NCO045144 I11 12 17/10/05 11' - 18 ICI Section D. Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Site Review 1 Permit The current permit became effective on July 1, 2016 and expires on April 30, 2021 A copy of the current permit was available for review Permitted nomponents include a septic tank, sand filter, UV disinfection and backup chlorination 2 Facility Site Review The facility was as described in the permit Access to the site is restricted by a chain link fence. Wastewater is dosed to the sand filter with a siphon mechanism, not a pump. A high water alarm is not present in the dosing tank. 3 Operation and Maintenance The operator or a properly designated backup visits the site as required. Visitation logs were current and available during the inspection It was noted that our list of designated operators is not up to date. Please complete and submit the enclosed operator designation form so that our database can be updated Previous inspections noted that the sand bed appeared increasingly worse with time While the bed's operation could not be evaluated during the inspection, it should be maintained to ensure proper operation Mr Smith said that the bed is occasionally raked by maintenance staff 4 Flow Measurement Flow is estimated using data from the potable water meter 5 Effluent/Receiving Waters The effluent Is discharged Into the Haw River in the Cape Fear River Basin. The outfall was visible from the bridge over the Haw River on Gerringer MITI Road There was a slight discharge during the inspection The stream did not appear to be negatively impacted. Documentation Review 6 Records/Reports Discharge Monitoring Reports (DMRs) and lab data are maintained according to the permit. DMRs Include all permit parameters. Copies of DMRs, operator visitation logs, lab reports and Cham -of -Custody forms were available for review during the inspection 7 Self -Monitoring Program A review of DMRs from January, 2016 through July, 2017 showed no violations, and a comparison of submitted DMR data and field records showed no errors or concerns. 8. Laboratory All parameters are analyzed by Research & Analytical Laboratories, Certification #34 ORC measures pH and temperature at the facility All other samples are collected by the ORC and analyzed at the main laboratory. pH meter pre -run calibration and sampling procedures appeared acceptable However, Mr Smith said that a post analysis calibration check was not performed. Please refer to the enclosed technical Page# Permit NCO045144 Owner - Facility western Alamance High School - inspection Date: 10/05/2017 - inspection Type- Compliance Evaluation assistance document, which states that "When performing analyses away from the certified laboratory's primary location, a post analysis calibration verification using the check standard buffer must be analyzed at the end of the run " Temperature Is measured using the digital thermometer on the Dissolved Oxygen meter. It was noted that the last calibration of this meter was performed on October 6, 2016. Mr Smith said he would have the main laboratory perform the calibration within the coming days 9 -Sludge Handling Disposal Mr Smith said that the septic tank is usually emptied twice per year Records of the removal were available on site The tank was pumped on 8/2017, 10/2016, 8/2016, and 2/2015 by Jenkins Waste Management Page# Permit NCO045144 Owner - Facility western Alamance High School Inspection Date- 10/05/2017 Inspection Type Compliance Evaluation Operations $ Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? M ❑ ❑ ❑ Does the facility analyze process control parameters, for ex- MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires In 6 months or less) Has the permittee submitted a new ❑ ❑ 0 ❑ application? 0 ❑ ❑ ❑ Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? ❑ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ❑ ❑ ❑ Comment. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? 0 ❑ ❑ ❑ Are all records maintained for 3 years (lab reg. required 5 years)? 0 ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? M ❑ ❑ ❑ Is the chain -of -custody complete? ❑ ❑ ❑ 0 Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses ❑ Transported CDCs 0 Are DMRs complete- do they include all permit parameters? M ❑ ❑ ❑ Has the facility submitted Its annual compliance report to users and DWQ? ❑ ❑ M ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ M ❑ on each shift? Is the ORC visitation log available and current? M ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? M ❑ ❑ ❑ Page# 4 Permit NCO045144 Owner - Facility Western Alamance High School Inspection Date -10/05/2017 - Inspection Type Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 ❑ Comment: In the Operator's loci book, it looked like there was only one visit In each of July and August. Mr. Smith said he did visit the plant but did not record it. I reminded him to record ever Yes No NA NE # Is flow meter used for reporting? visitation 0 ❑ ❑ Chain of Custody - it is not known whether the laboratory maintains a more complete copy ❑ ❑ Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ❑ ❑ 110 ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: Flow Measurement - Influent Yes No NA NE # Is flow meter used for reporting? ❑ 0 ❑ ❑ Is flow meter calibrated annually? ❑ ❑ ❑ 0 Is the flow meter operational? M ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ M ❑ Comment: Flow is estimated from the water usage. School is connected to a municipal public water ❑ ❑ supply Water consumption is measured at the intake, and that is used to estimate the Is effluent clear and free of solids? 0 ❑ effluent. The outfall proiects several feet into the Haw River ❑ Disinfection - UV Yes No NA NE Are extra UV bulbs available on site? E ❑ ❑ ❑ Are UV bulbs clean? ❑ ❑ ❑ 0 Is UV intensity adequate? ❑ ❑ ❑ 0 Is transmittance at or above designed level? ❑ ❑ ❑ 0 Is there a backup system on site? 0 ❑ ❑ ❑ Is effluent clear and free of solids? 0 ❑ ❑ ❑ Comment. UV system is in a fullv contained tube A panel in the control box indicates whether each bulb Is functioning, and an arm can be moved to clean the bulbs from the outside The panel indicated that all 6 bulbs were running. There was an extra bulb on site, and the ORC said he had the ability to obtain chlorine tablets in case of an outage Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational? ❑ ❑ 0 ❑ Is septic tank pumped on a schedule? N ❑ ❑ ❑ Page# 5 Permit NCO045144 Inspection Date 10/05/2017 Owner - Facility- western Alamance High School Inspection Type- Compliance Evaluation Septic Tank Yes No NA NE Are pumps or syphons operating properly? 0 ❑ ❑ ❑ Are high and low water alarms operating properly? ❑ ❑ 0 ❑ Comment: Septic tank has at least 2 compartments with a capacity of at least 21.000 gallons There are no pumps or alarms. There is a siphon mechanism that doses to the sand filter once the level in the dosing tank reaches a certain volume. The grease/solids level in the tank appeared to be acceptable. Sand Filters (Low rate) Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational'? ❑ ❑ 0 ❑ Is the distribution box level and watertight? ❑ ❑ 0 ❑ Is sand filter free of ponding? ❑ ❑ ❑ M Is the sand filter effluent re -circulated at a valid ratio? ❑ ❑ 0 ❑ # Is the sand filter surface free of algae or excessive vegetation? 0 ❑ ❑ ❑ # Is the sand filter effluent re -circulated at a valid ratic? (Approximately 3 to 1) ❑ ❑ M ❑ Comment Water did not run through the sand filter during the inspection The ORC said that there is no way to recirculate efFleunt. Previous inspections indicated that the sand media looked Progressively worse. I retained a picture during the inspection to keep as a record. ORC said that the sand is raked every couple weeks but has not been replaced. Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? 0 ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? 0 ❑ ❑ ❑ # Is the facility using a contract lab? M ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6 0 degrees ❑ ❑ ❑ Celsius)? Incubator (Fecal Coliform) set to 44 5 degrees Celsius+/- 0 2 degrees? ❑ ❑ ❑ Incubator (BOD) set to 20 0 degrees Celsius +/-1 0 dagrees? ❑ ❑ ❑ 0 Comment: Did not conduct inspection durina a samDlina day. However. ORC demonstrated his technique for calibrating pH meter and I verified that the thermometer had been calibrated within the last year. ORC does not perform a calibration check at the end of the run Thermometer calibration was due again this month. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ ❑ Is sample collected below all treatment units? ❑ ❑ ❑ Is proper volume collected? Is the tubing clean? ❑ ❑ ❑ ■ ❑ ❑ N ❑ Page# 6 Permit- NCO045144 Owner - Facility western Alamance High School -inspection-Date: 10/0512017 InspectiorrType• Compliance Evaluation- _ Effluent Sampling Yes No NA NE # Is proper temperature set for sample storage (kept at less than or equal to 6 0 degrees ❑ ❑ ❑ 0 Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type ] ❑ ❑ ❑ representative)? Comment. Inspection was not conducted during a sampling day. However. ORC demonstrated his technique for obtaining grab samples. Page# 7