Loading...
HomeMy WebLinkAboutNC0004774_Site Review_20170928j� Water Resources Environmental Quality September 28, 2017 Mr. Henry Botkins Station Manager 1385 Dukeville Road Salisbury, North Carolina 28146 SUBJECT: Site Review Buck Combined Cycle Station NPDES Permit NC0004774 Rowan County, NC Dear Mr. Botkins: ROY COOPER Governor MICHAEL S. REGAN Secretary S. JAY ZIMMERMAN Director On September 7, 2017, Roberto Scheller of this Office conducted a site review at the subject facility. This site review was conducted to insure discontinued use of domestic wastewater treatment package plant and connection onto non -discharge septic system. During the onsite visit, it was noted that subject package plant was pumped out and removed on September 18, 2017. Enclosed is a copy of the letter from the NC Operators Certification Program, classifying the subject facility as Grade 1 Physical -Chemical Water Pollution Control Treatment System (PC -1). We wish to thank your operating staff for their assistance regarding this inspection. The enclosed report should be self-explanatory; however, should you have any questions, please do not hesitate to contact myself or Roberto Scheller at (704) 235-2204 or roberto.scheller@ncdenr.gov. Sincerely, • W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ Enclosed cc: email: Dale.Wooten@duke-energy.com Wastewater Branch MSC 1617 — Central files basement File T+Je�tl�ia�g Comp,ares:.-tip State of North Carolina I Environmental Quality 1611 Mail Service Center I Raleigh, North Carolina 27699-1611 919-707-9000 United States Environmental Protection Agency Form Approved EPA Washington, D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A National Data System Coding (i e , PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 2 15 1 3 I NCO004774 I11 12 17/09/26 17 18 L R I 19 I � j 201 211 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 166 IInnspecbon Work Days Facility Self -Monitoring Evaluation Rating 61 QA -Reserved------ 671 70 71 itJI 72 N LJ L, l I I 73 I X74 751 I I I I I I I8O Section B Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09 30AM 17/09/26 12/01/01 Buck Steam Station 1555 Dukeville Rd Exit Time/Date Permit Expiration Date Salisbury NC 28146 10 20AM 17/09/26 16/08/31 Name(s) of Onsite Representative(s)lfitles(s)/Phone and Fax Number(s) Other Facility Data Dale Wooten/ORC/704-630-3086/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Henry A Botkins,1385 Dukeville Rd Salisbury NC 28146/Station Manager -EM II Regulated Stations/704-630-3019/ No Section C Areas Evaluated During Inspection (Check only those areas evaluated) Facility Site Review Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date ,Roberto Scheller MRO WQ//252-946-6481/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date W Corey Basinger MRO WQ//704-235-2194/ EPA 60-3 LRev 9-94) Ikevious editions are obsolete .'00 Page# NPDES yr/mo/day Inspection Type 31 NC0004774 I11 12 17/09/26 17 18 p I Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On 09/18/2017 the wastewater package plant was pumped out and package plant removed from site Wastewater is now being treated via septic tanks and nitrification field This facility is no longer discharging treated domestic wastewater to surface waters 1 _ 5 Page# 2 September 28, 2017 SENT VIA EMAIL TO: HENRY.BOTKINS@DUKE-ENERGY.COM Henry A Botkins, Jr Buck Steam Station Manager Duke Energy Carolina LLC 1385 Dukeville Road Salisbury, North Carolina 28146 Dear Mr Botkins, ROY COOPER bowl nor MICHAEL S. REGAN Secreiurn Subject: Classification of Water Pollution Control System (PC -1) Buck Steam Station WWTP NC0004774 Rowan County In accordance with North Carolina General Statute § 90A-37, the Water Pollution Control System Operators Certification Commission is required to classify all water pollution control systems Upon review of the subject permit and after discussion with the DWR's Mooresville Regional Office staff the Water Pollution Control System Operators Certification Commission has determined that the subject facility is classified as follows • Grade 1 Physical -Chemical Water Pollution Control Treatment System (PC -1) [15A NCAC 08G 0302(f)] If you have any questions concerning this classification or the designation of operators, please contact me at 919-707-9038, or via email at maureen kinney@ncdenr gov. Sincerely, J "Wj� NC Operators Certification Program ec. Paul Draovitch, Senior VP EH & S, Duke Energy Carolinas LLC (Paul Draovitch@duke-energy com) Henry Botkins, Jr , Buck Steam Station Mananger, Duke Energy Carolinas LLC (henry botkins@duke-energy com) Ross Hartfield, Environmental Specialist, Duke Energy Carolinas LLC (ross hartfield@duke-energy com) Brent File, Superintendent of Operations, Duke Energy Carolinas LLC (brent file@duke-energy com) Roberto Scheller, Mooresville Regional Office, Water Quality Regional Operations Mike Templeton, DWR, NPDES Permitting Central Files, NC0004774 Permit/Correspondence File State of North Carolina I Environmental Qualm 1618 Mail Service Center I Raleigh, North Carolina 27699-1618 919-807-6353