Loading...
HomeMy WebLinkAboutNC0043125_Compliance Evaluation Inspection_20170905September 5, 2017 W J Hogan Patterson School Foundation Inc PO Box 500 Patterson, NC 28661-0500 SUBJECT: Compliance Inspection Report Patterson School NPDES WW Permit No. NCO043125 Caldwell County Dear Mr. Hogan: ROTCOOPIR S Y rN C��rr,��[ RECEIVED/NCDEO/DWR SEP 2 5 2017 Water Qualay Permitting Section The North Carolina Division of Water Resources conducted an inspection of the Patterson School on 8/16/2017. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0043125. You were present for this inspection. The system was discharging at the time of the inspection; samples must be obtained; flows must be estimated and submittal of monitoring reports are required per the permit. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". If you should have any questions, please do not hesitate to contact me at 828-296-4500 or via email at linda.wiggs@ncdenr.gov. Si`n�c�erely, kl; Linda Wiggs Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS -Inspection Report Cc WQS Asheville Regional Office NPDES Compliance/Enforcement Unit G \WR\WQ\Caldwell\Wastewater\Minors\Patterson School 43125\Inspections\NC0043125.CEI 82017 rtf State of North Carolina I Environmental Quality I Water Resources 2090 U S 70 Highway, Swannanoa, NC 28778 828-296-4500 United States Environmental Protection Agency Form Approved EPA Washington, D C 20460 OMB No 2040-0057 Water Comphance Insprcction- Report ` ` ' "' 7XppT6val expires 8-31-98 - '- Section A National Data System Coding (i e, PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 1 3 I NCO043125 111 12 17/08/16 17 18 L G A 19 S 20H 211 1 1 1 1 11 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11___1 1 1 1 1 f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ------Reserved---------- 67 70 LJ I 71 I 72 L N C 73 �74 751 111 I I I 180 LJ Section B Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10 OOAM 17/08/16 14/03/01 Patterson School 4646 Patterson School Dr Exit Time/Date Permit Expiration Date Lenoir NC 28645 11 30AM 17/08/16 18/10/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted W J Hogan,PO Box 500 Patterson NC 286610500//828-728-3189/8287545065 No Section C Areas Evaluated During Inspection (Check only those areas evaluated) Permit E Operations & MaintenancE 0 Records/Reports Facility Site Review Effluent/Receiving Waters Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Linda SlWWiggsARO WQ//828-296-4500 Ext4653/ 1 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete Page# NPDES yr/mo/day Inspection Type (Cont) 1 31 NCO043125 I11 12 17/08/16 _ 17 18 U Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The Inspector, Linda Wiggs, met bnsite with the ORC, Jim Hogan We discussed process controls such as settleability test and sludge fudge measurements Because the School has been closed since 2009, normal Operations and Maintenance have not been taking place Solids have not been removed since 2008 Air is cycled twice a day for 15 minutes DMRs submitted report No Flow However, Caldwell County Schools will begin sending students (-50) to Patterson School, which will increase flows During the inspection flows were observed coming into the plant and leaving the plant We discussed sampling and flow requirements If the plant has flcw, samples must be obtained, flows must be estimated and submittal of monitoring reports are required per the permit Page# 2 Permit NCO043125 Owner - Facility Patterson School' Inspection Date 08/16/2017 Inspection Type. Compliance Evaluation Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment Discussed settleability and sludge fudge with CIRC. Permit (If the present permit expires In 6 months or less) Has the permittee submitted anew application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the Inspector granted access to all areas for Inspection? Yes No NA NE ■ ❑ ❑ ❑ ❑ ■ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ ® ❑ ❑ ❑ ❑ ■ ❑ ❑ ■ ❑ ❑ ❑ N ❑ ❑ ❑ Comment The facility is listed as a WW I, but should be a WW II However, the ORC stated he is certfied for WW II Bar Screens Type of bar screen Yes No NA NE a Manual ❑ Mode of operation b Mechanical ❑ Type of aeration system Are the bars adequately screening debris? E ❑ ❑ ❑ Is the screen free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screening in compliance? 0 ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment The bar screen is a combo comminuter The comminutor was not working and the ORC Does the foam cover less than 25% of the basin's surface? 0 ❑ stated it had not worked in a while, but was not causing issues with the plant. ❑ Is the DO level acceptable? ❑ ❑ Aeration Basins Yes No NA NE Mode of operation Type of aeration system Is the basin free of dead spots? ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ N ❑ Are the diffusers operational? 0 ❑ ❑ ❑ Is the foam the proper color for the treatment process? ❑ ❑ 0 ❑ Does the foam cover less than 25% of the basin's surface? 0 ❑ ❑ ❑ Is the DO level acceptable? ❑ ❑ ❑ N Page# 3 Permit. NCO043125 Owner - Facility Patterson School Inspection Date 08/16/2017 Inspection Type- Compliance Evaluation Aeration Basins Yes No NA NE Is the DO level acceptable?(1 0 to 3 0 mg/1) ❑ ❑ ❑ N Comment There was no foam present The ORC has the air set for two 15 m nute cycles The air cycles may need Increasing when the Caldwell County students come back Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids In center well of circular clarifier? ❑ ❑ 0 ❑ Are weirs level? ® ❑ ❑ ❑ Is the site free of weir blockage? 0 ❑ ❑ ❑ Is the site free of evidence of short-circuiting? 0 ❑ ❑ ❑ Is scum removal adequate? 0 ❑ ❑ ❑ Is the site free of excessive floating sludge? 0 ❑ ❑ ❑ Is the drive unit operational? ❑ ❑ 0 ❑ Is the return rate acceptable (low turbulence)? 0 ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? 0 ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately % of the sidewall depth) ❑ ❑ ❑ M Comment Page# 4