HomeMy WebLinkAbout19910022 Ver 2_Staff Comments_20170911Burdette, Jennifer a From: Homewood, Sue Sent: Monday, September 11, 2017 1:14 PM To: Burdette, Jennifer a Subject: Smithfield Foods Per the application narrative, a portion of the stormwater runoff will be collected within an underground detention stormwater system and the system will be drained via a stormwater pump and drainage channel. Please provide calculations of the storage volume that will be provided by the underground storage system, and design details of the pump system. Please provide calculations that show that the pumped stormwater will be discharged to the adjacent wetland at non-erosive velocities. On plan sheet C5.0 the "proposed underground detention" is identified with a note to refer to the Grading Plan. On plan sheet C6.0, Grading Plan, the same storm pipes are identified in the legend as "existing storm pipe". Please clarify existing storm pipes versus new storm pipes and ensure that any existing stormwater that is directed to the "underground detention" is accounted for in the storage calculations. Please provide specific construction drawings for the riprap level spreader and provide calculations to document that stormwater that sheet flows through this area will be non-erosive. Thanks, Sue Homewood Division of Water Resources, Winston Salem Regional Office Department of Environmental Quality 336 776 9693 office 336 813 1863 mobile Sue. Homewood@ncdenr.gov 450 W. Hanes Mill Rd, Suite 300 Winston Salem NC 27105 Email c'orretil'.)ol?"'{,ence to and ii`orn thio; a('{"'{I`ess o; sutJ ect to t1he Alotir"I Carolina Public Records L w and 1`Y7ay be dl`ii:'losed to thloi d I'.'s'ai{`ies,