HomeMy WebLinkAbout20170842 Ver 1_More Info Received_20170808Homewood, Sue From: Sent: To: Cc: Subject: Attachments: Hi All, Derek Goddard <derek@brec.biz> Tuesday, August 08, 2017 10:27 AM Homewood, Sue Elliott, William A SAW Re: Fleetwood Fire & Rescue SIGNED_C100.pdf, PROPOSED_IMPACTS_INVENTORY.pdf, SIGNED_C200.pdf Please see attached the revised Impacts table, revised plan, and a stream map showing the thalweg location of the stream. Please let me know if you need any more information. Thanks Derek On Mon, Jul 24, 2017 at 1:43 PM, Derek Goddard <derekgbrec.biz> wrote: Yes, correct. On Jul 24, 2017 1:33 PM, "Homewood, Sue" <sue.homewood(c�r�,ncdenr.gov> wrote: Just to clarify, you mean the 221 road improvements currently ongoing? Thanks, Sue Homewood Division of Water Resources, Winston Salem Regional Office Department of Environmental Quality 336 776 9693 office 336 813 1863 mobile Sue. Homewood a-ncdenr.gov 450 W. Hanes Mill Rd, Suite 300 Winston Salem NC 27105 1 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Derek Goddard [mailto:derek e brec.biz] Sent: Monday, July 24, 2017 10:58 AM To: Homewood, Sue <sue.homewoodkncdenr.gov> Cc: william.a.elliottkusace.army.mil Subject: Re: Fleetwood Fire & Rescue Sue, Thanks for the review, My responses are inline below. On Sat, Jul 22, 2017 at 3:33 PM, Homewood, Sue <sue.homewood@ncdenr.gov> wrote: Derek, A few items that need to be addressed on this application: • The plans submitted with your application indicate that there is a pipe "proposed by NCDOT". We need to know if the roadway work is being done by DOT for the purpose of accommodating the Fire & Rescue station. My understanding from NCDOT is that this pipe is part of there roadway design and therefore permitted and mitigated that way and was not done to accommodate the FD. THE FD did not own this land until fairly recently. • This site drains to ORW waters, therefore it is subject to state stormwater permitting per 15A NCAC 02H .1021. You'll need to submit an application to the stormwater unit in Raleigh. If you have any questions about that please contact Robert Patterson in the stormwater unit. I will modify the PCN to indicate this falls under the ORW rules and will not review the low density supplement that you submitted. Noted and I will submit there. • Your plans do not show the existing stream location/alignment. We need to see the surveyed stream location and you need to determine impact length as the length of the thalweg of the stream, not the length of the pipe. Please submit a modified plan sheet and update the impact table in the PCN and reseed that page with the changes. I have requested this information from the survey firm ( We did not do the TOPO survey) Thanks, Sue Homewood Division of Water Resources, Winston Salem Regional Office Department of Environmental Quality 336 776 9693 office 336 813 1863 mobile Sue. Homewood(a)ncdenr.gov 450 W. Hanes Mill Rd, Suite 300 Winston Salem NC 27105 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. I. r �* .f •F' � _ / � COQ \ IL SWALE #1 GRASS LINE CHANNEL TO BE MA • ' �• +� 9111% '; WITH CURLEX7_11 I IF , i ♦ i CLASS B RIPRAP ,�, • • f OUTLET PROTECTIOK O c O SWALE #2 GRASS LINED CHANNEL TO BE MATTED iZ WITH CURL EX.II O�- r o 1 lw `r i 4- -, > CLASS B RIPRAP r f s - OUTLET PROTECTION O `0 , .-_ o SWALE #3 GRASS LINED ��►� r WAAIKIM T(1 RG NAATTr-n pf. k4 O P �`f `yti ^ �' !•� r+ ♦yam` '► * 7a . - I SITE INFORMATION i ...' ; • APPROXIMATE PROPOSED IMPERVIOUS SURFACE IS 24% I • � fir: - +' 'All,�' =' ,` 'f ` `. - w"�' IMPACT TABLE f � r. ,'.. 1` r ,,� .s mak' y Mw✓ I,.. -1 r �.' "s:.:•,NUMBER LENGTH *? ��� ,�'{1' - a � ��•� mss. "! � ` ♦ • .' �?' ` - 1 1450F 36" RCP V. ij'y ! .� r .� - tea._ • , 1 � ,-. .�" _ -- s' d �� - ^ : ,,,y:'}'fid, �• . r I 1 1 - r _ 4 r .4% • q 6 Z i 0 C7 0 m GO �� T TO OLD FIEL S '* C EEK - C;Tr,OR `+ CL SSIFICATION r ' a Q RE IN L HELI -PAD FOR AIR CARE M COIR TRANSPORT ING ON ' EEDED 00 ti _ Cep f Col. i • 1 LI � f W �.; N ` 4k 411 IC CLASS B ...r. SWALE #5 GRASS LINED 1` ti OUTLET PROTECTION CHANNEL • BE MATTED Ilk WITH CURLEX 11 00, 7'` Donald Blackburn, et—al _ A DB 167, P 1793 OUT WTECTION�• SWALE #6 GRASS LINED .....CHANNEL TO BE MATTED WITH CURLEX © COPYRIGHT 2017 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE .0, \, \ \ \IIIIII//// N CAR 0 3 36 = N C. CN 08/08/2017 ,1111111111..1, NCBELS#C-3448; •%�0,A� • • ... • Off'\�0 ,w; •, CAF' Lu U) Lu J O Lu Q Q D ui w uim U) Z J rQ �./ O Z 0 Z O STREAM & SITE LOCATION MAP � PREPARED FOR: CJS FLEETWOOD VOLUNTEER z O FIRE & RESCUE U 9005 HWY 221 SOUTH of FLEETWOOD, NC 28626 U- 0 uJ cn DATE: REVISIONS: W w O Z 1 w SHEET SIZE: 24"x36" W DATE: 06/23/2017 PROJECT NUMBER: U 3340012017 Z w DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH O SCALE: LL 0 1" = 50' (H) Lu (V) 50 25 0 50 100 SHEET: W C200 13S H33 dWOO V SV CEA1303�1381Sf1W SWd - 3WOS lON 00 NOiionl I1SNOO �JOJ 03SV33 3 1 lON - QOOMl33]J M3IA3�I AON3!DV �JOJ 03SV33 3 1 ti X CN NO cq co CD Q CV NC) 3: m v p U o M W O O fn w U Lu _ U) U m LLJ Z > W Lij W LULU ¢ LO Wao U) co •••,,,,11111,,,,,', LU 1111 QOOMl33]J M3IA3�I AON3!DV �JOJ 03SV33 3 1 ti X CN NO cq co CD Q CV NC) 3: m v p U o M W O O fn w U Lu _ U) U m LLJ Z > W Lij W LULU ¢ LO Wao U) co C. Proposed Impacts Inventory 1. Impacts Summary 1a. Which sections were completed below for your project (check all that apply): ❑ Wetlands X Streams -tributaries ❑ Buffers ❑ Open Waters ❑ Pond Construction 2. Wetland Impacts If there are wetland impacts proposed on the site, then complete this question for each wetland area impacted. 2a. 2b. 2c. 2d. 2e. 2f. Wetland impact Type of jurisdiction number- Type of impact Type of wetland Forested (Corps - 404, 10 Area of impact Permanent (P) or (if known) DWQ - non -404, other) (acres) Temporary W1 El P r_1 T El Yes [I Corps ❑ No ❑ DWQ W2 El P ❑ T El Yes El Corps ❑ No ❑ DWQ W3 ❑ P ❑ T ❑ Yes ❑ No ❑ Corps ❑ DWQ [I Yes [:]Corps W4 [I P ❑ T ❑ No ❑ DWQ W5 ❑ P ❑ T El Yes L] Corps ❑ No ❑ DWQ El Yes [I Corps W6 El P F-1 T ❑ No ❑ DWQ 2g. Total wetland impacts 2h. Comments: 3. Stream Impacts If there are perennial or intermittent stream impacts (including temporary impacts) proposed on the site, then complete this question for all stream sites impacted. 3a. 3b. 3c. 3d. 3e. 3f. 3g. Stream impact Type of impact Stream name Perennial Type of jurisdiction Average Impact number- (PER)or (Corps -404,10 stream length Permanent (P) or intermittent DWQ - non -404, width (linear Temporary (T) (INT)? other) (feet) feet) S1 X P F-1 T Culvert UT to Old Fields X PER X Corps 1 145 Creek El INT X DWQ S2 P X T Pump Around UT to Old Fields Creek X PER ❑ INT X Corps X DWQ 1 10 S3 ❑ P ❑ T ❑ PER ❑ Corps ❑ INT ❑ DWQ El ❑ Corps S4 El P F1 T ❑ INT ❑ DWQ SS ❑ P ❑ T [__1 PER El Corps ❑ INT ❑ DWQ [I PER I -] Corps S6 El P ❑ T ❑ INT ❑ DWQ 3h. Total stream and tributary impacts 150 3i. Comments: The stream volume and velocity will not require a rip rap dissipater pad in the stream at the outlet of the pipe. Page 5 of 11 PCN Form -Version 1.3 December 10, 2008 Version