Loading...
HomeMy WebLinkAbout20070776 Ver 3_More Info Received_20081117I? WADETRIM November 14, 2008 401 Oversite/Express Review Permitting Unit NCDENR - Division of Water Quality Parkview Building 2321 Crabtree Boulevard, Suite 250 Raleigh, North Carolina 27604 Attention: Ms. Annette Lucas Re: Waynesville Commons, Haywood County DWQ Project # 07-0776 ve.9, 3 Lot 2 - Best Buy Dear Ms. Lucas: DO NOV 1 7 2008 DENR . WATER QUALITY WETLANDS AND STORMWATER BRANCH In response to your October 30, 2008 comment letter received by our office on November 4, 2008, we offer the following comments: 1. Overall Site a. Our previous submittal included a new Sheet C-2.2 which is a drainage map indicating drainage boundary, storm pipes, inlets and catch basins, treatment areas, bypass structures, bypass pipes, and outlets for this outparcel. We have revised this sheet accordingly based on the comments below. 2. Wet Detention Pond a. We have converted this basin to an excessively large forebay and storage basin. The basin is now an aesthetic pond, but also provides as a forebay and holds our water quality volume prior to entering the sand filter. b. We have added a sand filter located under the parking lot similar to the other two sand filters for this development. The outlet orifice directs the water quality volume to a sand filter for additional treatment. We have added details for this sand filter on Sheet C-2.1. Piping to and from the sand filter are detailed on Sheet C-2.1 and C-3.0. The bypass structure remains as previously designed to allow flows in excess of the water quality volume to by pass the forebay and storage pond. c. The sand filter is 14ft by 30ft. The filter is fed with 6" pipes a manifold and 3 row of 6" perforated pipe in a layer of washed stone. A minimum of 2 feet of sand is located below the layer of washed stone and 6" distribution piping. At the bottom of the filter is 3 rows of 4" perforated piping, a header, and discharge pipe to the bypass piping. The bed is wrapped in geotextile. The stone and sand are separated with geotextile. Cleanouts have been provided for all laterals. The Wade Trim, Inc. 828.665.1288 1200 Ridgefield Boulevard 828.665.9566 fax Suite 145 www.wadetrim.com Asheville, NC 28806 Page 2 Ms. Annette Lucas November 14, 2008 bottom of the filter and collection piping slopes at 0.50%. The bottom of the filter is at least 2 feet above the SHWT. The specification for the perforated piping has been referenced on the plan. The perforated piping is standard ADS pipe with a sock. The Stormwater maintenance easement shown on Sheet C-1.0 has been expanded to include the sand filter area. We have included our calculations, supplement, Hydrocad modeling results, and technical notes for the perforated pipe. A signed operation and maintenance agreement is forthcoming under separate cover. Sand Filter behind building a. The sand filter is open at the surface, but the bottom and sides of the filter are closed because the design calls for a PVC liner. With a PVC liner, the system is closed with respect to ground water. b. We have adjusted the slopes of the discharge piping to 0.50% minimum. This was accomplished by elevating or raising the entire sand filter up 0.5 feet. This change in vertical elevation did not affect the volumes, capacities, or design function of the system. We have re-run the Hydrocad modeling and re-checked our calculations to ensure this change did not affect design. We have enclosed new copies of these reports and calculations for your file. The 6" outlet at the splitter box is now 0.15 feet higher than the 15" bypass pipe. We do not expect clogging to occur with this change in elevation. c. We have added a second 4" drain below the sand filter inclusive of inspection ports and cleanouts. We have specified the perforations by referencing the manufactures technical bulletin on the plans. We have included a copy of this specification for your file/review. On the Section B-B view on Sheet C-2.1, we have indicated the spacing of the laterals. d. Our sand filter is unusual in shape as the flow enters at the long end. Even flow distribution which could result in overloading and clogging at the leading edge of the sand filter was a concern during the design. To mitigate this concern, we propose to use a pipe distribution system, mimicking an underdrain system, to evenly distribute flow from the sediment basin (forebay) to sand filter media (per section 11.3.4 of the BMP manual). Calculations for this design were included in our previous submittal. e. We have consulted with our geotechnical engineer on your concern regarding the side slopes. I have attached a copy of our correspondence with him. He has indicated that the areas should hold up. He also indicated that some sloughing and erosion is likely. However, please consider that the slopes are only about 2.5 to 3.5 feet tall, the slopes in the sand filter area are protected with PVC liner, and the sediment basin are will have sod stapled to the slopes. Additionally, no overland flow is directed to these slopes, only what rain falls from the sky on these slopes. Also, the slopes in the sand filter area are covered with PVC, eliminating the concern for erosion from water. The forebay has sod stapled on the slopes which provides for immediate protection from erosion. With respect to his comment regarding the wall, we have raised the sand filter 0.5 feet and the foundation for the wall is below the elevation of the sand in our Page 3 Ms. Annette Lucas November 14, 2008 filter. Loss of soil on the side slopes of the sand filter will not create a detriment or unstable condition for the adjacent wall. Additionally, the operation and maintenance agreement requires inspection quarterly and within 24 hours of every storm greater than 1.0 inches. These inspections will entail inspection of the perimeter of the sand filter. If it is determined that failure of the side slopes has occurred and continue to occur over a period of time, additional measures will be taken to strengthen the side slopes. Lastly, based on the soils present at the site and personal observation, near vertical walls can be constructed (or excavated) in these soils. In worst conditions, the angle of repose is 1:1 or 45 degrees. There is no question in my mind, that if properly constructed and compacted, the soils and slopes can be constructed with 1:1 slopes. Please let us know of additional submittal requirements or if you have any questions Sincerely, WADE TRIM, INC. J. Chris <4arles ssociate cjc CDW2009-OIE wteim:projectwiw\Documents\Land Development\Projects\Cdw2009\Ole\Docs\Storm WaterTot 2\Submittal Cover 2008-11-14.doc Enclosures cc: Mr. David Scarnati, Cedarwood Development, Inc. IN WADETium WORK SHEET -)? ?e4 are&-- - P66,,e ? Lam; -35 314 3 EV a.0, 0,96 7- 4- t4v` k' xk7v x4 12v 6 75- ? t, l ? rI uj(v = )117e 6ff W ?v .,'dJ . . 0,-76-. A 7q,5,#.:- ?9 e-)1?4 ??6dllrv-ck?l- dveL,--, 45 ;zv6, ev - .4- - ? a )qo 1-izJoo-C A-3 SUBJECT Z BY CHK. SME NO /pgt?MBER DATE DATE ..OF._ G 0 Form 2&1092 ?IV 4, b? ? ?k ? WADETium WORK SHEET Z) -7q 6IC-1 k; ?y h? 64T 36, a 7qg , 1,5- V19 7 , VSZ .6. , hd -5w, , /a-5v JA -- /D,. 45- SUBJECT (f3 BY CHK. SHEET / Jp8 NUMBER DATE DATE • • Form 25.1092 iN WADETium WORK SHEET dc V-i- X'd 175 Ste 4s7-/q 633 (?' j?(.?. i Tl k.l? l?U-?-'° ? 5 T? ? C74,y. 2 ?• 7r7 / t^ t ?J d-er 4h 04 hzj (qt4 dym :?-- II/C j 5oQ ?? U ts?(?. J -- 1 U S i A G (o yL - c• vo - o d l,-s cc Jlnd aU-UTV, ?15t?we 3 2?98 ?-?- liar- l ,?• ?? Obi 2 SUBJECT BY CHK. SHE 0. JOB NUMBER -k--l DATE DATE OF • • Forth 25-1 M iN WADETium WORK SHEET 3 C9. 005 Pipe 4' p t f l u, (o pr-op (YA IcA d<fs? r- C(,(c I 7? 6-?5 ?4?Z c?s, 9 OcA .,s > IOU E??l zA ?©l t7 2,0 163 215 A Z Z 4-5 "l I 1 ?-T w Q = 2.1716 1 0..20 = ?I0 C-f f 591 %? SG6 44 " o K I SUBJECT .!7 -s "4 DATE OATE - 1 SHE O. / JOB NUMBER • • Form 25.1092 ? WADETRim WORK SHEET 54. 2? 55 .o? ?,; ? gc? ? 2.754 (22`3 r ., 4Q(t?o3Oove-, Aeocl t ?G?a 2?5L450 33 ( 179 2 429 7 c r? 02 7 ?? 6 (2--2, r ©2 + ? 2?q SS' c l-- 0 ?It e-5 SUBJECT BY CHK. SHE?ET JOB NUMBER DATE DATE OF __Y?- • • :orm 25-1092 IN WADETRim WORK SHEET -? 0,he6ji, g it P;lp 617 J-0 [J C ??l .- I ij I v T Q O,go a a.35 Q,2? r (v •p °n lam. 6 OA? jto• G?2?boc1 ? -D1D 6. .0 M-5 Gb ©.q o A Nvc- ?? ?Glti ?jliG h d???! 5 b.00214?3 „ -D?o ' -?. 2.2. 01 C)K1 SUBJECT jyl BY CHK. SHE NO. JOB NUMBER DATE DATE OF Forth 251092 DA2 Roof and Loading Dock, Drainage Area 2 SF Sand Filter 44Reach on Link t Best Buy Sand Filter Drainage Area 2 Type 11 24-hr 100yr Rainfall=7.46" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Subcatchment DA2: Roof and Loading Dock, Drainage Area 2 Hydrograph 10 s.a7 crs --- Type It 24-hr 1 QOr Rainfall---74f"- - - 6 RUno Area=$53344- Runoff :Volume=21,24 - - -9 ?f -- Runoff Depth-7:22'' 6 l -! 0 5- Flow Length=293' U. 4 Tc-3!0 min 3 N98 2 -- - -- ------- - ¦ Runoff 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Time (hours) Best Buy Sand Filter Drainage Area 2 Type// 24-hr 100yr Rainfall=7.46" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Summary for Subcatchment DA2: Roof and Loading Dock, Drainage Area 2 Runoff = 9.47 cfs @ 11.93 hrs, Volume= 21,249 cf, Depth= 7.22" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Type II 24-hr 100yr Rainfall=7.46" Area (sf) CN Description 30,399 98 Paved parking & roofs 4,915 98 Paved parking & roofs 35,314 98 Weighted Average 35,314 Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft ) (ft/sec) (cfs) 2.3 160 0.0100 1.16 Sheet Flow, Roof Smooth surfaces n=0.011 P2=3.28" 0.7 133 0.0050 3.21 2.52 Circular Channel (pipe), Storm Diam= 12.0" Area= 0.8 sf Perim= 3.1' r= 0.25' n= 0.013 Corruaated PE, smooth interior 3.0 293 Total Best Buy Sand Filter Drainage Area 2 Type 1124-hr 1 yr Rainfall=3.00" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Pond SF: Sand Filter Hydrograph Inflow :A: sf 4 Pei - El ev?2 5'.7 02 ;Storage=4,7157 d 3- 2- LL _ -- ------ - ¦ Inflow ? Outflow ¦ Primary ¦ Secondary 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Time (hours) Best Buy Sand Filter Drainage Area 2 Type// 24-hr 1yr Rainfall=3.00" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Summary for Pond SF: Sand Filter Inflow Area = 35,314 sf,100.00% Impervious, Inflow Depth = 2.77" for lyr event Inflow = 3.77 cfs @ 11.93 hrs, Volume= 8,147 cf Outflow = 0.14 cfs @ 13.24 hrs, Volume= 8,147 cf, Atten= 96%, Lag= 78.4 min Primary = 0.07 cfs @ 13.24 hrs, Volume= 7,918 cf Secondary = 0.06 cfs @ 13.24 hrs, Volume= 228 cf Routing by Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Peak Elev= 2,757.02'@ 13.24 hrs Surf.Area= 1,773 sf Storage= 4,757 cf Plug-Flow detention time= 659.8 min calculated for 8,145 cf (100% of inflow) Center-of-Mass det. time= 659.9 min ( 1,411.1 - 751.1 ) Volume Invert Avail.Storage Storage Description #1 2,753.50' 5,643 cf Custom Stage Data (Irregular) Listed below (Recalc) Elevation Surf.Area Perim. Inc.Store Cum.Store Wet.Area (feet) (sq-ft) (feet) (cubic-feet) (cubic-feet) (sq-ft) 2,753.50 942 215.0 0 0 942 2,754.50 1,175 226.0 1,056 1,056 1,387 2,755.00 1,271 224.0 611 1,668 1,520 2,755.50 1,418 237.0 672 2,340 2,011 2,756.50 1,652 242.0 1,534 3,873 2,317 2,757.00 1,769 245.0 855 4,728 2,485 2,757.50 1,889 248.0 914 5,643 2,655 Device Routing Invert Outlet Devices #1 Primary 2,753.50' 1.750 in/hr Exfiltration over Horizontal area #2 Secondary 2,752.35' 15.0" x 42.0' long Culvert CPP, square edge headwall, Ke= 0.500 Outlet Invert= 2,751.45' S= 0.0214'/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior #3 Device 2 2,757.00' 8.5' long Sharp-Crested Rectangular Weir 2 End Contraction(s) Primary OutFlow Max=0.07 cfs @ 13.24 hrs HW=2,757.02' (Free Discharge) t-1=Exfiltration (Exfiltration Controls 0.07 cfs) econdary OutFlow Max=0.06 cfs @ 13.24 hrs HW=2,757.02' (Free Discharge) Culvert (Passes 0.06 cfs of 11.88 cfs potential flow) 3=Sharp-Crested Rectangular Weir (Weir Controls 0.06 cfs @ 0.42 fps) Best Buy Sand Filter Drainage Area 2 Type 11 24-hr 10yr Rainfall=5.07" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Pond SF: Sand Filter 3 0 LL Hydrograph [6.12d$ Area=35;344-sf--- 5.97 ds e E'lev 2 57. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5.5 'Storage=5,375 d 1 ¦ Inflow ? Outflow ¦ Primary ¦ Secondary 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Time (hours) Best Buy Sand Filter Drainage Area 2 Type 11 24-hr 10yr Rainfal1=507" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 0 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Summary for Pond SF: Sand Filter Inflow Area = 35,314 sf,100.00% Impervious, Inflow Depth = 4.83" for 10yr event Inflow = 6.42 cfs @ 11.93 hrs, Volume= 14,223 cf Outflow = 5.97 cfs @ 11.96 hrs, Volume= 14,223 cf, Atten= 7%, Lag= 1.3 min Primary = 0.08 cfs @ 11.96 hrs, Volume= 8,990 cf Secondary = 5.89 cfs @ 11.96 hrs, Volume= 5,232 cf Routing by Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Peak Elev= 2,757.36'@ 11.96 hrs Surf.Area= 1,854 sf Storage= 5,375 cf Plug-Flow detention time= 450.3 min calculated for 14,223 cf (100% of inflow) Center-of-Mass det. time= 450.3 min ( 1,191.2 - 740.9 ) Volume Invert Avail.Storage Storage Description #1 2,753.50' 5,643 cf Custom Stage Data (Irregular) Listed below (Recalc) Elevation Surf.Area Perim. Inc.Store Cum.Store Wet.Area (feet) (sq-ft) (feet) (cubic-feet) (cubic-feet) (sq-ft) 2,753.50 942 215.0 0 0 942 2,754.50 1,175 226.0 1,056 1,056 1,387 2,755.00 1,271 224.0 611 1,668 1,520 2,755.50 1,418 237.0 672 2,340 2,011 2,756.50 1,652 242.0 1,534 3,873 2,317 2,757.00 1,769 245.0 855 4,728 2,485 2,757.50 1,889 248.0 914 5,643 2,655 Device Routing Invert Outlet Devices #1 Primary 2,753.50' 1.750 in/hr Exfiltration over Horizontal area #2 Secondary 2,752.35' 15.0" x 42.0' long Culvert CPP, square edge headwall, Ke= 0.500 Outlet Invert= 2,751.45' S= 0.02147' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior #3 Device 2 2,757.00' 8.5' long Sharp-Crested Rectangular Weir 2 End Contraction(s) Primary OutFlow Max=0.08 cfs @ 11.96 hrs HW=2,757.36' (Free Discharge) L1=Exfiltration (Exfiltration Controls 0.08 cfs) econdary OutFlow Max=5.87 cfs @ 11.96 hrs HW=2,757.36' (Free Discharge) Culvert (Passes 5.87 cfs of 12.37 cfs potential flow) 3=Sharp-Crested Rectangular Weir (Weir Controls 5.87 cfs @ 1.95 fps) Best Buy Sand Filter Drainage Area 2 Type 11 24-hr 100yr Rainfall=7.46" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Pond SF: Sand Filter Hydrograph 2.47 ds 9.Cr, Inflow';Area=35,3'''14 sf 10 9.;a??8 Peak E1eV?2,7$7- g' 9 -" Storage'=5-,60 cf - -- ---- ------- 8 7- 7 H 6 , U. 5 4 -- -- - 3 -- - - - 2 1 " ¦ Inflow ? Outflow ¦ Primary ¦ Secondary 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Time (hours) Best Buy Sand Filter Drainage Area 2 Type 11 24-hr 100yr Rainfall=7.46" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 0 2007 HvdroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Summary for Pond SF: Sand Filter Inflow Area = 35,314 sf,100.00% Impervious, Inflow Depth = 7.22" for 100yr event Inflow = 9.47 cfs @ 11.93 hrs, Volume= 21,249 cf Outflow = 9.17 cfs @ 11.95 hrs, Volume= 21,235 cf, Atten= 3%, Lag= 0.9 min Primary = 0.08 cfs @ 11.95 hrs, Volume= 9,622 cf Secondary = 9.10 cfs @ 11.95 hrs, Volume= 11,613 cf Routing by Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Peak Elev= 2,757.48'@ 11.95 hrs Surf.Area= 1,884 sf Storage= 5,602 cf Plug-Flow detention time= 336.9 min calculated for 21,231 cf (100% of inflow) Center-of-Mass det. time= 336.7 min ( 1,071.8 - 735.1 ) Volume Invert Avail.Storage Storage Description #1 2,753.50' 5,643 cf Custom Stage Data (Irregular) Listed below (Recalc) Elevation Surf.Area Perim. Inc.Store Cum.Store Wet.Area (feet) (sq-ft) (feet) (cubic-feet) (cubic-feet) (sq-ft) 2,753.50 942 215.0 0 0 942 2,754.50 1,175 226.0 1,056 1,056 1,387 2,755.00 1,271 224.0 611 1,668 1,520 2,755.50 1,418 237.0 672 2,340 2,011 2,756.50 1,652 242.0 1,534 3,873 2,317 2,757.00 1,769 245.0 855 4,728 2,485 2,757.50 1,889 248.0 914 5,643 2,655 Device Routing Invert Outlet Devices #1 Primary 2,753.50' 1.750 in/hr Exfiltration over Horizontal area #2 Secondary 2,752.35' 15.0" x 42.0' long Culvert CPP, square edge headwall, Ke= 0.500 Outlet Invert= 2,751.45' S= 0.0214'/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior #3 Device 2 2,757.00' 8.5' long Sharp-Crested Rectangular Weir 2 End Contraction(s) Primary OutFlow Max=0.08 cfs @ 11.95 hrs HW=2,757.48' (Free Discharge) L1=Exfiltration (Exfiltration Controls 0.08 cfs) econdary OutFlow Max=9.08 cfs @ 11.95 hrs HW=2,757.48' (Free Discharge) Culvert (Passes 9.08 cfs of 12.54 cfs potential flow) 3=Sharp-Crested Rectangular Weir (Weir Controls 9.08 cfs @ 2.26 fps) Permit NuinWr: (to be provided bj,1)WQ) Drainage Arco Number: Sand Filter Operation and Maintenance Agreement I will keep a maintenance record on this BMP. This maintenance record will be kept in a log in a known set location. Any deficient BMP elements noted in the inspection will be corrected, repaired or replaced immediately. These deficiencies can affect the integrity of structures, safety of the public, anti the removal efficiency of tile BMP. Important maintenance procedures: - The drainage area will be carefully managed to reduce the sediment load to the sand filter. - Once a year, sand media will be skimmed. - The sand filter media will be replaced whenever it fails to function properly after vacununmg. The sand filter will be inspected quarterly and within 24 hours after every storm event greater than 1.0 inches (or 1.5 inches if in a Coastal County). Records of operation and maintenance will be kept in a known set location and will be available upon request. Inspection activities shall be performed as follows. Any problems that are found shall be repaired inunediately. LIMP element: Potential problem: How I will remediate the problem: The entire BMP Trash/debris is resent. Remove the trash/debris. The adjacent pavement Sediment is present on the Sweep or vacuum the sediment as (if applicable) pavement surface. soon as possible. The perimeter of the Areas of bare soil and/or Regrade the soil if necessary to sand filter erosive gullies have formed. remove the gully, and then plant a ground cover and water until it is established. Provide lime and a one-time fertilizer application. Vegetation is too short or too Maintain vegetation at a height of long. a roximatel six inches. The flow diversion Tile structure is clogged. Unclog the conveyance and dispose structure of an sediment off-site. The structure is damaged. Make any necessary repairs or replace if damage is too large for -repair. The pretreatment area Sediment has accumulated to Search for the source of the a depth of greater than six sediment and remedy the problem if inches. possible. Remove the sediment and dispose of it in a location where it will not cause impacts to streams or the BMP. F-,rosion has occurred. Provide additional erosion protection such as reinforced turf matting or riprap if needed to prevent future erosion problems. Weeds are present. Remove the weeds, preferably by hand. If a pesticide is used, wipe it on tile1?lants rather than spraying. Form SW40I-Sand Filter O&M-Rev.3 Pagc I of'3 BMP element: Potential problem: How I will remediate the problem: The filter bed and Water is ponding on the Check to see if the collector system underdrain collection surface for more than 24 is clogged and flush if necessary. If system hours after a storm. water still ponds, remove the top few inches of filter bed media and replace. If water still ponds, then consult an expert. The outflow spillway Shrubs or trees have started Remove shrubs and trees and pipe to row on the embankment. immediately. The outflow pipe is clogged. Provide additional erosion protection such as reinforced turf matting or riprap if needed to prevent future erosion problems. The outflow pipe is damaged. Repair or replace the pipe. The receiving water Erosion or other signs of Contact the NC Division of Water damage have occurred at the Quality 401 Oversight Unit at 919- outlet. 733-1786. Form SW401-Sand Filter O&M-Rev.3 Page 2 of '3 Permit Number: (to be pi-ovided by UIVQ) I acknowledge and agree by my signature below that 1 am responsible for the performance ofthe maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. Proiect uameMaynesville Commons - Best Buy Lot 2 __...._ BA4P cb iiuage urea uumbet-: Print namc:David A. Scarnati Title:Director of Development Address: 1765 Merriman Road Akron 011 44313 Phone:330-869-2763 Signature: Date: Note: The legally responsible party should not be a homeowners association unless more than 501/o of the lots have been sold and a resident of the subdivision has lien named the president. _LA -St?L, , a Notary Public for the State of ?h['O County of do hereby certify that D/R ?i y /a Se t?", -A personally appeared before me this .-I day of e U a-uor , and acknowledge the due execution of the forgoing sand filter maintenance requirements. Witness my liand and official seal, \\,\,\11\IIIIIII/,,,,,, A1Al - Julie A. Lasky -?? Resident Summit County * * = Notary Public, State of ON * `° r s My Commission Expires: 0510 20 '?, J'lATf 0 f O??o\. '??1,1111\ I\\II\\`\\\, SIAL - a My commission expires 5--A// Z Form SW401-Sand Filter 0&!vl-Rev. 3 Page 3 of' 3 u .' Christy, Charles From: Matthew McCurdy [MMcCurdy@smeinc.com] Sent: Tuesday, November 11, 2008 2:31 PM To: Christy, Charles Cc: David Scarnati Subject: RE: Waynesville - Best Buy Chuck, The slopes are steeper than typically is considered stable, but since the finished slopes are only about 2.5 to 3.5 feet tall, most areas should hold up. Some sloughing and erosion is likely in areas over time and the need for maintenance of the slopes should be expected. Loss of soil around the wall that is only 1 foot away could cause damage, so the bottom of the wall needs to be low enough to reduce that chance. Matt Matt McCurdy, PE Project Engineer *113"d ME ENGINEERING INTEGRITY. SWE, Inc. 44 Buds Shoals Road, Unit C3 Arden NC 28704 Map Ph: 828-687-9080 Fax: 828-687-8003 mmccurdy@smeinc.com www.smeinc.com This electronic message and its attachments are forwarded to you for convenience and "for information only." The message may represent a summary with limitations, conditions and further explanations omitted in the interest of brevity and time constraints. The contents of this electronic message and any attachments may be preliminary and incomplete, subject to review and revision. If this electronic transmittal contains Findings, Conclusions or Recommendations, S&ME, Inc. will submit a follow-up hard copy via mail or overnight delivery for your records, and this hard copy will serve as the final record. In the event of conflict between electronic and hard copy documents, the hard copy will govern. This electronic message and any attachments transmitted with it are the property of S&ME, Inc. and may contain information that is confidential or otherwise protected from disclosure. The information this electronic message contains is intended solely for the use of the one to whom it is addressed, and any other recipient should delete this electronic message and destroy all copies. VER 4, Rev 1 - 031207 From: Christy, Charles [mailto:CCHRISTY@WadeTrim.com] Sent: Monday, November 10, 2008 3:36 PM To: Matthew McCurdy Cc: David Scarnati 11/14/2008 Subject: Waynesville - Best Buy Matt, Can you look at the sand filter detail on this sheet, lower left hand corner. we are proposing to construct the sand filter with side slopes of 1:1. The depth to bottom of sand will range from 3.5 to 4.35 feet. The depth from top of sand will range from 2.0 to 2.7 feet. We propose to cover the slopes with PVC and sod stapled to the slope. NCDENR has expressed a stability concern with regards to the proposed slopes. Can you review and determine that the slopes will be stable to construct and stable after completion. Let me know if you have any questions. A response via email will be fine as we are trying to respond to DENR as soon as possible. Thanks, Chuck Wade Trim, Inc. Charles J. Christy, PE, Associate Land Development Services Office: 828.665.1288 Cell: 828.337.0251 (24-7) Fax: 828.665.9566 11/14/2008 .... + TECHNICAL NOTE TN 1.02 Single Wall HDPE Perforation Patterns October 2008 Nominal I.D. Perforation Type Maximum Slot Length or Diameter Maximum Slot Width Minimum Inlet Area Pattern Type in mm in mm in mm in"/ft cm-/m 3 75 Slot 0.875 22 0.120 3 1.0 21 A 4 100 Slot 0.875 22 0.120 3 1.0 21 B - 5 125 Slot 0.875 22 0.120 3 1.0 21 B 6 150 Slot 0.875 22 0.120 3 1.0 21 B 8 200 Slot 1.18 30 0.120 3 1.0 21 B - 10 250 Slot 1.18 30 0.120 3 1.0 21 B 12 300 Slot 1.50 38 0.118 3 1.5 32 B 12 300 Circular 0.313 8 - - 1.5 32 C 15 375 Circular 0.313 8 + - - 1.5 32 C 18 450 Circular 0.313 8 - - 1.5 32 C 24 600 Circular 0.313 8 - - 2.0 42 D TYPE A PATTERN 45' 45' 2 SLOT PATTERN PERFORATIONS ROTATED 90' EVERY OTHER VALLEY 8 HOLE PATTERN TYPE B PATTERN 3 SLOT PATTERN PERFORATIONS ROTATED 60' EVERY OTHER VALLEY TYPE D PATTERN 6 HOLE PATTERN 2 I 4640 TRUEMAN BLVD. HILLIARD, OH 43026 (800) 821-6710 www.a"pe.com 1 ATN102 ®ADS 2008 Techn i0 ca W NotesTechnical Note 2.105 Re: Outflow from Perforated Pipe Date: January 2004 (Published May, 2004) Introduction In order to provide guidance to the engineering community in designing drainage or recharge systems, ADS has conducted theoretical computations using an orifice equation. It should be emphasized that ADS conducted these calculations using ADS standard perforation patterns, and that the values are based on free outlet (no backfill) through the perforations. Infiltration is assumed to be equal to the calculated exfiltration rate. When designing storm water drainage or recharge systems, the goal in mind is to calculate the amount of storm water which can escape the pipe and replenish the ground water. Although some may believe that the controlling parameter is the free outflow from the perforated pipe, this is not often the case. A perforated pipe can only discharge water at a rate at which the surround- ing soil will accept it. Procedure The goal is to calculate the free outflow from the perforations in a pipe. Knowing the perforation hole diameter and hole pattern, a simple orifice equation can be used to calculate the flow rate in cubic feet per second. Orifice equation QP = CdA 2gH Where QP = free out fall flow rate through one perforation (ft3/sec) Cd = Coefficient of discharge = 0.60 A = Cross sectional area of one perforation (fe) g = Gravimetric constant = 32.2 ft/secz H = Height of water above perforation, head (ft) Having the orifice equation, the location of the perforations with respect to the invert of the pipe and the size of perforations, the free outflow at any elevation in the pipe can be calculated. To calculate the amount of flow per foot of pipe, or unit length, simply multiply the free outflow in one valley by the number of valleys per foot of pipe. With the above procedure, we can calculate the free outflow at any given elevation provided the perforation orientation is known. Looking at a typical curve inside a pipe cross section, (Chart 1.) the curve is somewhat jumpy and not uniform throughout the pipe cross section. As the water head increases, however, the curve becomes more uniform and looks much more like a curve produced from using the orifice equation, Chart 2. The non-uniform part of the curve is due to the additional perforations holes at higher elevations inside the pipe cross-section, producing what can be characterized as hydraulic jumps. 4840 TRUEMAN BLVD. HILLIARD, OH 43026 (800) 821-6710 http://www.ad"ipe.com When designing a pipe in typical storm sewer design, the pipe is assumed to be flowing full. For the purposes of this technical note, charts have been provided showing the relationship between free outflow and water head elevation when the pipe is full. Placed on these charts is a second order polynomial which best describes the data. This polynomial may be used to estimate the free outfall at various head elevations. The designer should keep in mind that, for some applications and some pipe sizes, the free outfall from the pipe perforations may be larger than the flow rate of the pipe itself and thus the pipe may not flow full. This, however, will only exist in applications where the water is purely in a free outflow state and is not inhibited by the surrounding soil. The determining factor for recharge systems is the surrounding soil's ability to accept water, not the pipe's ability to deliver water. Although the perforations in the pipe determine the allowable area at which water can be released, it is the soil's ability to accept the water that is the determining factor in designing recharge systems. This can best be described with the following example: Example A 12" diameter drainage pipe is used to recharge the ground water table through very permeable backfill envelope (coefficient of permeability, K = 1,000 m/d = 0.0375 ft/s). The ground water table is 3 feet below the pipe. The 12" diameter pipe has a total of 36 - 0.375" diameter holes per foot of pipe (area at which water enters the backfill envelop, A = 0.0276 ftz/foot of pipe). Assume the pipe is full; determine the outfall rate of storm water through the pipe alone, (no backfill) and the acceptance rate of the soil envelope. A) The outfall rate of the 12" pipe has been determined using the aforementioned procedure for determining the free outflow of a perforated pipe. Q pir, fr, = 0.086 ft;/s/ft = 38.7 gpm./foot of pipe. TOP OF GRADE PIPE `-SURROUNDIN WITH PERNE FT L = 3 FT GROUND WATER TABLE Figure 1. B).Using Darcy's Law one can solve for the flow through the soil. % = KiA Where, Q = Flow rate through soil, ft'/s K = The permeability of the soil = 0.0375 ft/s i = Hydraulic gradient (AH/L), ft/ft A = Area (sum of the areas from the perforations) = 0.0276 fe % = 0.0375 ft x 3 ft x 0.0276 ft' = 0.0014 ft per foot of soil along the pipe Or Qs = 0.63 gallons per foot of soil along the pipe, Q, << Qp min. As the example shows, the flow rate through the soil is much less than the flow rate through the pipe perforations. Although the area at which water can reach the soil is determined by the pipe perforations, the surrounding soil determines the flow rate through the soil. When designing drainage or recharge systems, one should reference the minimum inlet areas listed in ADS Product Note 3.106, AASHTO M294, or contact the pipe manufacturer for a detailed explanation of its pipe's perforation pattern. OUTFLOW - ADS PIPE PIPE NOT FULL 120- 100- P 80- 60-- 3 0 u. 40 u. 20 0 0 2 4 6 8 10 12 14 16 18 20 22 HEAD (INCHES) Chart 1. ORIFICE EQUATION 14- 12- 10- U) V_ 8 O g 4-- 2 0 0 5 10 15 20 25 30 HEAD (FEET) Chart 2. 3 I i 3 f i t# R I 1 + (+i rn i co ri 1 + X co N O 4 O S II T ! s t d s r 1 r s 6 qi f U CO ? N a to U A N U N v U T o ? 'v a i r S Cam' i r cc a N we (. zQ a U) CL C) _ awJ CL U. J -j = ? LL LL U) Oa V 'Cr co (O et tV O CQ tp v N r r r .-r S UJIMS) MOIJ m LO IT (n N LO 0 O co 'd' co N , O rk r? co M (D Cl) v co N Cl) M W x co z N O co N x v N N N O N Go I r O O co It N O /I (f ?. t G" C Aw ~ W a U) Q? Q W OJ IL LL. J 0 = LL ? Q o? co N O N M x CA Co x co to N O O T a a c U N U ? N U m iD CL I . d O 000 C D O V O N O c o t 0 D N a C) N r r r r (.U/WdD) MO-14 O tD 00 to CD to N LO O U) co Q CD v v N O d' OD M CD M co co N N M w x o z M N = to N N N N 0 N O CD N r O r co CD N O O c? s:"C . .r l W o r=? a z as Nay t/1 O uj -j a IL LL J J 0 = m U. OV CO I tsi N x CD M O Ch t x fl- M N O O 11 s n a 3 I 0 0- D- CO U i c N U ? I 1 N U ' y f0 f U 1 i 0 co 0_ I ? ` G ? R to O 0 0 0 co OIt N C) Q O 000 CO O D V N N - r r - r CUIMO) MO-1 A O CD co M co to N O LO co cD v N Cl IT 00 M co N N M ui x U O z M ;r 00 N W CD N N N N O N 00 co ,It r N O co - cD N O O N'WADETRim WORK SHEET 1.2tl lei Drd-j'tjaj,,.,- Orewl-, a ss 73 ;f} ?t?A4 oe4? ? (-6-ffvlc , U4 pv 14b U 117' NOV 1 7 2008 GENR ',NA:TFR WATER BR WETLANDS AND oTt*M tt'lvv "j ti L# 2 c? 1 I+l` v 27? 1. Sb - z7577 hmtt N '2 1? Z 4 z- "315-Std" , 51 C/, 3z-e- Ajc4-e c,,d r r6-4 Af = j Z -;a 360 4s ,e4 _ `7`f9 // nr • CHK SHEETNO. MNUMBER -= DATE (? / 7i bk DATE OF Caw • 2LtD f •V r {_ Form 25.1082 IN'WADETium WORK SHEET ' J h,LS Ike Vol io P&AJ 1770.2q_ ( p?yrtx pwl e-le-v) t& z? 1?dt/'Cad (trrt bn f"J Vol i P <L>A.+2..J - Lom. 5 ? v o-o (? ? l Z1?t A Z ?66.,z5 _D?-((' q Re?' d L4 A Vul Q 1? ojJ',-'G-d ve-rA -Z,Q1 '> G4 W ('T V ` "1 ,G16 r Z60/0 +?-' / (1, lee O K' 0 aunxL i I BY cw. SHEET NO. JOB NU BER J DATE I J13 In - DATE OF _ 700 % ' O[ c"', -am 25.1092 - 1? - - N'WADETium WORK SHEET ?ejfav_ot (/)(kslvt 0,,ec4_, /:, 1 V? AV ?t, -3043 ff 2. 415 PGY' f 4"Cc' C1 (? ?? U U 5 ?T s- a ?j ? I L? + 5&j F%, 14? &4 ?U? 4te_ A lecl, s IN4 y 2 • 2.0 v 2?•5J A? :?: 4,1 i ?ff , ? Prov,14 ' o x 4-2 0 s4 fI?+d??. SUBJECT BY CHK. SHEET NO. JOB NUMBER 5 DATE 1 3 DATE of ?bw • Zp0 -ole Form 25-1092 [N* WADETRim WORK SHEET ? si -Ft 5 ???/? j ? h? o I w?, LVI , 4ok k4wiitx w s-c, O,bif S 0.4 0005 0. S' Cave. IcIr ? ?c?o Gad -(? & "Dl '!?T-Pf OuToa 'Pi peg , SUBJECT SWET 6/5? Bull FDATE ( roe ' DATE DF Zoeq - Form 2sw 9- 7 U) O Permit Number. (to be provided by DWQ) n AC*, WWNR STORMWATER MANAGEMENT PERMIT APPLICATION FORM 401 CERTIFICATION APPLICATION FORM SAND FILTER SUPPLEMENT This form must be filled out on line, printed and submitted with all of the required information. Make sure to also fill out and submit the Required Items Checklist (Section 1I1) and the I&M Agreement (Section IV) oa?? wAr?q°? r P Y I. PROJECT INFORMATION Project name Waynesville Commons - Best Buy, Lot 2 Contact name Charles J. Christy Phone number 828-337-0251 Date Drainage area number November 13, 2008 Parking Lot, Drainage Area 1 II. DESIGN INFORMATION Site Characteristics Drainage area (AD) Impervious area % Impervious (IA) Design rainfall depth (RD) Peak Flow Calculations 1-yr, 24-hr runoff depth 1-yr, 24-hr intensity Pre-development 1-yr, 24-hr runoff Post-development 1-yr, 24-hr runoff Pre/Post 1-yr, 24-hr peak control Storage Volume Design volume (WQV) Adjusted water quality volume (WQVW? Volume contained in the sedimentation basin and on top of the sand filter Maximum head on the sedimentation basin and sand filter (hM F,I,) Average head on the sedimentation basin and sand filter (hA) Runoff Coefficient (Rv) Type of Sand Filter Open sand filter? If this is an open sand filter: The clearance between the bottom of the sand filter and the SHWT (dww) Closed/pre-cast sand filter? If this is a dosed sand filter: The clearance between the bottom of the sand filter and the SHWT (dam) If this is a dosed, underground closed sand filter: The clearance between the surface of the sand filter and the bottom of the roof of the underground structure (dam,) 60,814.00 ft2 OK 57,530.00 ft2 94.6%% 1.00 in in in/hr Wises fe/sec fe/sec 4,625.00 ft' 3,468.75 ft' OK 15,030.00 3.75 ft OK 1.88 ft OK 0.90 (unitless) N Yor N Y Yor N 1.00 ft Form SW401-Sand Filter-Rev, 3 Parts I and 11. Project Design Summary, Page 1 of 3 Permit Number: (to be provided by DWQ) Sedimentation Basin Surface area of sedimentation basin (As) OK. Meets minimum, but may need to be increased to 3,588.00 fe contain the required volume if error under Storage Volume section. Sand Filter Surface area of sand filter (AF) Depth of the sand media filter bed (dF) Coefficient of permeability for the sand filter (k) Time to drain the sand filter (t) Time to drain the sand filter (t) Additional Information Does volume in excess of the design volume bypass the sand filter? Is an off-line flow-splitting device used? Does volume in excess of the design volume Clow evenly distributed through a vegetated filter? What is the length of the vegetated filter? Does the design use a level spreader to evenly distribute flow? Is the BMP located at least 30ft from surface waters (50ft if SA waters)? Is the BMP located at least 100ft from water supply wells? Are the vegetated side slopes equal to or less than 3:1 Is the BMP located in a recorded drainage easement with a recorded access easement to a public Right of Way (ROW)? What is the width of the sedimentation chamberlforebay (Wsw)? What is the depth of sand over the outlet pipe? OK. Meets minimum, but may need to be increased to 420.00 ft' contain the required volume 4 error under Storage Volume section. 2.00 ft 3.50 (It/day) 40.00 hours OK. Submit drainage calculations. 1.67 days Y YorN OK Y Y or N OK N Y or N Excess volume must pass through filter. It Yor N Y Yor N OK Y Y or N OK Y Y or N OK Y Y or N OK 30.00 it OK 1.67 it OK Figure 1: Open Sand Filter SedlUkCadaholt S:arJ Fdtei C'tnwber '6+6rr 1 or For ebax. r «''u Flow rotlet khl.e 1_`ff I:'tt } Tu-Sdu Sort a Seagouabh? Iirsh Witter Table ................................. w_., iIP'P' iiF ;W ....... ... ' 6Hwr Form SW401-Sand Filter-Rev-3 Parts I and It. Project Design Summary, Page 2 of 3 Wen \.\ Floc "Welland \ 1'onitetc for other 4hnchual tuatcuall hi-Situ Soil/ Seasonably Hi0i Watct Table Watel Collected Figure 2: Closed Sand Filter llti Covet r3t.dc.? \ 4-hillct Pipe pace ................ ..........t :tlPipe \ .................. : 1js F i+ 46wr tiedunet?tatton OItantbet rF:6cbavr i Sand Ftltet r'9tmubcr rHc•?vy yedm?mts, ('TrappcA aohds? :............: '1 SuJ Permit Number: (to be provided by DWO) Form SW401-Sand Fitter-Rev.3 Parts 1 and II. Project Design Summery, Page 3 of 3 Permit No. (to be provided by DWQ) III. REQUIRED ITEMS CHECKLIST Please indicate the page or plan sheet numbers where the supporting documentation can be found. An incomplete submittal package will result in a request for additional information. This will delay final review and approval of the project. Initial in the space provided to indicate the following design requirements have been met. If the applicant has designated an agent, the agent may initial below. If a requirement has not been met, attach justification. Initials Pagel Plan Sheet No. 1. Plans (1" - 5(Y or larger) of the entire site with labeled drainage area boundaries li - 7'0 - System dimensions (length, width, and depth) for both the sedimentation chamber and the filter chamber C - Z t - Maintenance access, C ' - Flow splitting device, - Proposed drainage easement and public right of way (ROW), ?? - j.0 - Design at ultimate build-out, C - I.0 - Off-site drainage (if applicable), and WA - Boundaries of drainage easement. C - 2112- L? 2. Plan details (1" = 50' or larger) for the sand filter showing: - System dimensions (length, width, and depth) for both the sedimentation chamber and the filter chamber e .. Z.I - Maintenance access, 1.0 - Flow splitting device, - 2.1 - Proposed drainage easement and public right of way (ROW), C-1,0 - Design at ultimate build-out, C - j.0 - Off-site drainage (if applicable), and GJ,4 - Boundaries of drainage easement. C - `2 - Z " ' 3. Section view of the sand filter 0 = 20 or larger) showing: - Depth(s) of the sedimentation chamber and sand filter chamber, C -,2 . - Depth of sand filter media C, 2,i' - Connection between the sedimentation chamber and the sand filter chamber, - SHWT level(s) C - 2 . j - Outlet pipe, and C - 2. t t C- - Clearance from the surface of the sand filter to the bottom of the roof of the underground structure (if applicable) F. (, ?,?b 2. So foal 9,c-f ?Z760. Z4 ((-if) 4. A soils report that is based upon an actual field investigation, soil borings, and infiltration tests. The results of the soils report must be verified in the field by DWO, by completing & submitting the soils investigation request form. County soil maps are not an acceptable source of soils informatior . c?Z. t ?? t it t1J4 r 12o ,N?? Nw i , ,?7n,c? r? c. xd L (rs 5. Supporting calculations (including drainage calculations) 6. Signed and notarized operation and maintenance (O&M) agreement %r2 iH Cbrtit,-^9 (t ?! 7. A copy of the deed restrictions (if required). e';; &) S ( 0eA- ? Form SW401-Sand Finer-Rev.3 Part III, Page 1 of 1 DA1 on Parking Lot, Drainage Area 1 Pond Su4 Reach on Link Best Buy Wet Basin-Sand Filter Drainage Area 1 v4 Type// 24-hr 1yr Rainfall=3.00" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD®8 50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Subcatchment DA1: Parking Lot, Drainage Area 1 7 Hydrograph 6- -- 5- 4- 0 -- -- LL 3 2 1 -------- -------- -- 24'; hip--'lyr Type-It Rainfall=3.00 Ranof f ??r6al= 0:8,f 4 S. Runoff o ume Runoff popth;_-2.65',' Flow--Length=359' T&2.4 rain ¦ Runoff 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 Time (hours) Best Buy Wet Basin-Sand Filter Drainage Area 1 v4 Type// 24-hr 1 yr Rainfall=3.00" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Summary for Subcatchment DA1: Parking Lot, Drainage Area 1 Runoff = 6.41 cfs @ 11.93 hrs, Volume= 12,934 cf, Depth= 2.55" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-60.00 hrs, dt= 0.01 hrs Type II 24-hr lyr Rainfall=3.00" Area (sf) CN Description 57,530 98 Paved parking & roofs 3,284 61 >75% Grass cover, Good, HSG B 60,814 96 Weighted Average 3,284 Pervious Area 57,530 Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 1.0 80 0.0180 1.28 Sheet Flow, Parking Lot Smooth surfaces n= 0.011 P2= 3.28" 0.3 72 0.0050 4.17 3.28 Circular Channel (pipe), Pipe Diam= 12.00" Area= 0.8 sf Perim= 3.1' r= 0.25' n= 0.010 PVC, smooth interior 0.0 9 0.0050 4.17 3.28 Circular Channel (pipe), Pipe Diam= 12.00" Area= 0.8 sf Perim= 3.1' r= 0.25' n= 0.010 PVC, smooth interior 0.5 120 0.0050 4.17 3.28 Circular Channel (pipe), Pipe Diam= 12.00" Area= 0.8 sf Perim= 3.1' r= 0.25' n= 0.010 PVC, smooth interior 0.2 42 0.0025 3.42 4.20 Circular Channel (pipe), Pipe Diam= 15.00" Area= 1.2 sf Perim= 3.9' r= 0.31' n= 0.010 PVC, smooth interior 0.0 14 0.0025 4.68 14.70 Circular Channel (pipe), Pipe Diam= 24.00" Area= 3.1 sf Perim= 6.3' r= 0.50' n= 0.010 PVC, smooth interior 0.4 22 0.0001 0.94 2.94 Circular Channel (pipe), Pipe Diam= 24.00" Area= 3.1 sf Perim= 6.3' r= 0.50' n= 0.010 PVC. smooth interior 2.4 359 Total Best Buy Wet Basin-Sand Filter Drainage Area 1 v4 Type 1124-hr 10yr Rainfal1=5.07" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Subcatchment DA1: Parking Lot, Drainage Area 1 Hydrograph 12 2ds i Ty 4-hr''10yr ,o Rainfall''= w.a7" _ 9 - -Runoff Ara=0' 814'' sf ---------------------- -- - - ------------- - - --- 8- Runoff _ Volume =1 233; cf __ -- Zo o1r ':Runoff b_pth' 4.G il: 6 ---- ---' F1ow_ Length=359,' 5 Tc--2.4± min - 4 CN099-- 3 2 - - - - - - - - - - - - - - - - - -- - - - --- - - - ---- --- -------- -------- ---- ---- ----- -- ---- -------- ------------- --- ¦ Runoff 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 Time (hours) Best Buy Wet Basin-Sand Filter Drainage Area 1 v4 Type 11 24-hr 10yr Rainfall=5.07" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Summary for Subcatchment DA1: Parking Lot, Drainage Area 1 Runoff = 11.12 cfs @ 11.93 hrs, Volume= 23,323 cf, Depth= 4.60" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-60.00 hrs, dt= 0.01 hrs Type II 24-hr 10yr Rainfall=5.07" Area (sf) CN Description 57,530 98 Paved parking & roofs 3,284 61 >75% Grass cover, Good, HSG B 60,814 96 Weighted Average 3,284 Pervious Area 57,530 Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 1.0 80 0.0180 1.28 Sheet Flow, Parking Lot Smooth surfaces n=0.011 P2=3.28" 0.3 72 0.0050 4.17 3.28 Circular Channel (pipe), Pipe Diam= 12.00" Area= 0.8 sf Perim= 3.1' r= 0.25' n= 0.010 PVC, smooth interior 0.0 9 0.0050 4.17 3.28 Circular Channel (pipe), Pipe Diam= 12.00" Area= 0.8 sf Perim= 3.1' r= 0.25' n= 0.010 PVC, smooth interior 0.5 120 0.0050 4.17 3.28 Circular Channel (pipe), Pipe Diam= 12.00" Area= 0.8 sf Perim= 3.1' r= 0.25' n= 0.010 PVC, smooth interior 0.2 42 0.0025 3.42 4.20 Circular Channel (pipe), Pipe Diam= 15.00" Area= 1.2 sf Perim= 3.9' r= 0.31' n= 0.010 PVC, smooth interior 0.0 14 0.0025 4.68 14.70 Circular Channel (pipe), Pipe Diam= 24.00" Area= 3.1 sf Perim= 6.3' r= 0.50' n= 0.010 PVC, smooth interior 0.4 22 0.0001 0.94 2.94 Circular Channel (pipe), Pipe Diam= 24.00" Area= 3.1 sf Perim= 6.3' r= 0.50' n= 0.010 PVC, smooth interior 2.4 359 Total Best Buy Wet Basin-Sand Filter Drainage Area 1 v4 Type// 24-hr 100yr Rainfall=7.46" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Subcatchment DA1: Parking Lot, Drainage Area 1 Hydrograph 18 ------- - ----- 17 78.52 cfa 16 -- - - fip Il4-hr 1OOYt?-- 'Rain 14? 0814 f /fir f 6 s ,3 R n unoff r?fo Iume=X5;385' cf _ 11 - --------------------------- -- Ru6off DopthF$_98' 0 9 - ow Len?g#h=35 ' LL $ F 7 Tc_ 2 4- ruin g - ------ ----- C - - - - - - - - - - - - - - 4 3 -- 2 ------------ -- ---- --------- -------- --------- -------- ¦ Runoff 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 Time (hours) Best Buy Wet Basin-Sand Filter Drainage Area 1 v4 Type 11 24-hr 100yr Rainfall=7.46" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Summary for Subcatchment DA1: Parking Lot, Drainage Area 1 Runoff = 16.52 cfs @ 11.93 hrs, Volume= 35,385 cf, Depth= 6.98" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-60.00 hrs, dt= 0.01 hrs Type II 24-hr 100yr Rainfall=7.46" Area (sf) CN Description 57,530 98 Paved parking & roofs 3,284 61 >75% Grass cover, Good, HSG B 60,814 96 Weighted Average 3,284 Pervious Area 57,530 Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 1.0 80 0.0180 1.28 Sheet Flow, Parking Lot Smooth surfaces n=0.011 P2=3.28" 0.3 72 0.0050 4.17 3.28 Circular Channel (pipe), Pipe Diam= 12.00" Area= 0.8 sf Perim= 3.1' r= 0.25' n= 0.010 PVC, smooth interior 0.0 9 0.0050 4.17 3.28 Circular Channel (pipe), Pipe Diam= 12.00" Area= 0.8 sf Perim= 3.1' r= 0.25' n= 0.010 PVC, smooth interior 0.5 120 0.0050 4.17 3.28 Circular Channel (pipe), Pipe Diam= 12.00" Area= 0.8 sf Perim= 3.1' r= 0.25' n= 0.010 PVC, smooth interior 0.2 42 0.0025 3.42 4.20 Circular Channel (pipe), Pipe Diam= 15.00" Area= 1.2 sf Perim= 3.9' r= 0.31' n= 0.010 PVC, smooth interior 0.0 14 0.0025 4.68 14.70 Circular Channel (pipe), Pipe Diam= 24.00" Area= 3.1 sf Perim= 6.3' r= 0.50' n= 0.010 PVC, smooth interior 0.4 22 0.0001 0.94 2.94 Circular Channel (pipe), Pipe Diam= 24.00" Area= 3.1 sf Perim= 63 r= 0.50' n= 0.010 PVC. smooth interior 2.4 359 Total Best Buy Wet Basin-Sand Filter Drainage Area 1 v4 Type// 24-hr 1 yr Rainfall=3.00" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Pond Pond: Pond Hydrograph 6.41 ds --- - -- -- ,' - -A-'rea=6Q $ - , -' 'In'flo??rr't'? '?? -'PO 2,x$_1',.301--- 6 ,Storage:=12,70'0 d 5 ----, - - - -- 4 VL 3- ------------ ------- - ------- 2 ¦ Inflow ? Outflow ¦ Primary ¦ Secondary 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 Time (hours) Best Buy Wet Basin-Sand Filter Drainage Area 1 v4 Type// 24-hr 1 yr Rainfall=3.00" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 02007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Summary for Pond Pond: Pond Inflow Area = 60,814 sf, 94.60% Impervious, Inflow Depth = 2.55" for 1yr event Inflow = 6.41 cfs @ 11.93 hrs, Volume= 12,934 cf Outflow = 0.01 cfs @ 24.05 hrs, Volume= 1,061 cf, Atten= 100°/x, Lag= 727.7 min Primary = 0.01 cfs @ 24.05 hrs, Volume= 1,061 cf Secondary = 0.00 cfs @ 0.00 hrs, Volume= 0 cf Routing by Stor-Ind method, Time Span= 0.00-60.00 hrs, dt= 0.01 hrs Peak Elev= 2,761. 30'@ 24.05 hrs Surf.Area= 4,166 sf Storage= 12,700 cf Plug-Flow detention time= 1,750.2 min calculated for 1,061 cf (8% of inflow) Center-of-Mass det. time= 1,432.1 min ( 2,201.2 - 769.1 ) Volume Invert Avail.Storage Storage Description #1 2,756.00' 18,135 cf Custom Stage Data (Irregular) Listed below (Recalc) Elevation Surf.Area Perim. Inc.Store Cum.Store Wet.Area (feet) (sq-ft) (feet) (cubic-feet) (cubic-feet) (sq-ft) 2,756.00 508 176.0 0 0 508 2,757.00 1,148 240.0 807 807 2,637 2,758.00 1,914 268.0 1,515 2,321 3,797 2,759.00 2,754 291.0 2,321 4,643 4,858 2,760.00 3,456 310.0 3,098 7,741 5,815 2,760.25 3,588 314.0 880 8,621 6,028 2,760.50 3,722 318.0 914 9,535 6,244 2,761.00 3,995 326.0 1,929 11,464 6,685 2,761.50 4,280 335.0 2,068 13,532 7,186 2,762.00 4,572 343.0 2,213 15,745 7,650 2,762.50 4,991 398.0 2,390 18,135 10,898 Device Routing Invert Outlet Devices #1 Device 2 2,755.70' 24.00" x 142.0' long Culvert CPP, square edge headwall, Ke= 0.500 Outlet Invert= 2,755.36' S= 0.0024'/' Cc= 0.900 n= 0.010 PVC, smooth interior #2 Seconda ry 2,761.50' 8.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s) #3 Secondary 2,762.00' 15.0' long x 12.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.57 2.62 2.70 2.67 2.66 2.67 2.66 2.64 #4 Primary 2,760.25' 6.00" x 28.0' long Culvert CPP, square edge headwall, Ke= 0.500 Outlet Invert= 2,759.75' S= 0.01797' Cc= 0.900 n= 0.010 PVC, smooth interior #5 Device 4 2,759.25' 0.50" Horiz. Orifice/Grate Limited to weir flow C= 0.600 Best Buy Wet Basin-Sand Filter Drainage Area 1 v4 Type// 24-hr 1 yr Rainfall=3.00" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Primary OutFlow Max=0.01 cfs @ 24.05 hrs HW=2,761.30' (Free Discharge) L-4=Culvert (Passes 0.01 cfs of 0.85 cfs potential flow) t5=0rifice/Grate (Orifice Controls 0.01 cfs @ 4.94 fps) econdary OutFlow Max=0.00 cfs @ 0.00 hrs HW=2,756.00' (Free Discharge) Sharp-Crested Rectangular Weir ( Controls 0.00 cfs) Ah. 1=Culvert (Controls 0.00 cfs) 3=Broad-Crested Rectangular Weir (Controls 0.00 cfs) Best Buy Wet Basin-Sand Filter Drainage Area 1 v4 Type 11 24-hr 10yr Rainfall=5.07" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Pond Pond: Pond Hydrograph ¦ Inflow - ».?z ors - --i ? Outflow ¦ Primary nfl?wArea=4,814'sf I ¦ Secondary 12 !Peak-Elev=2,761,.69' . ,o Storage=?14,360'cf 9- 8' v 3 6 0 a 5 4- 2.20 ds 2.20 cfa 2 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 Time (hours) Best Buy Wet Basin-Sand Filter Drainage Area 1 v4 Type// 24-hr 10yr Rainfall=5.07" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Summary for Pond Pond: Pond Inflow Area = 60,814 sf, 94.60% Impervious, Inflow Depth = 4.60" for 10yr event Inflow = 11.12 cfs @ 11.93 hrs, Volume= 23,323 cf Outflow = 2.20 cfs @ 12.04 hrs, Volume= 10,682 cf, Atten= 80%, Lag= 6.6 min Primary = 0.01 cfs @ 12.04 hrs, Volume= 1,235 cf Secondary = 2.20 cfs @ 12.04 hrs, Volume= 9,447 cf Routing by Stor-Ind method, Time Span= 0.00-60.00 hrs, dt= 0.01 hrs Peak Elev= 2,761.69' @ 12.04 hrs Surf.Area= 4,390 sf Storage= 14,360 cf Plug-Flow detention time= 426.5 min calculated for 10,682 cf (46% of inflow) Center-of-Mass det. time= 297.5 min ( 1,052.4 - 755.0) Volume Invert Avail.Storage Storage Description #1 2,756.00' 18,135 cf Custom Stage Data ( Irregular) Listed below (Recalc) Elevation Surf.Area Perim. Inc.Store Cum.Store Wet.Area (feet) (sq-ft) (feet) (cubic-feet) (cubic-feet) (sq-ft) 2,756.00 508 176.0 0 0 508 2,757.00 1,148 240.0 807 807 2,637 2,758.00 1,914 268.0 1,515 2,321 3,797 2,759.00 2,754 291.0 2,321 4,643 4,858 2,760.00 3,456 310.0 3,098 7,741 5,815 2,760.25 3,588 314.0 880 8,621 6,028 2,760.50 3,722 318.0 914 9,535 6,244 2,761.00 3,995 326.0 1,929 11,464 6,685 2,761.50 4,280 335.0 2,068 13,532 7,186 2,762.00 4,572 343.0 2,213 15,745 7,650 2,762.50 4,991 398.0 2,390 18,135 10,898 Device Routing Invert Outlet Devices #1 Device 2 2,755.70' 24.00" x 142.0' long Culvert CPP, square edge headwall, Ke= 0.500 Outlet Invert= 2,755.36' S= 0.00247' Cc= 0.900 n= 0.010 PVC, smooth interior #2 Secondary 2,761.50' 8.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s) #3 Secondary 2,762.00' 15.0' long x 12.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.57 2.62 2.70 2.67 2.66 2.67 2.66 2.64 #4 Primary 2,760.25' 6.00" x 28.0' long Culvert CPP, square edge headwall, Ke= 0.500 Outlet Invert= 2,759.75' S=0.0179'/' Cc= 0.900 n= 0.010 PVC, smooth interior #5 Device 4 2,759.25' 0.50" Horiz. Orifice/Grate Limited to weir flow C= 0.600 Best Buy Wet Basin-Sand Filter Drainage Area 1 v4 Type 11 24-hr 10yr Rainfall=5.07" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Primary OutFlow Max=0.01 cfs @ 12.04 hrs HW=2,761.69' (Free Discharge) t4=Culvert (Passes 0.01 cfs of 1.03 cfs potential flow) L5=Orifice/Grate (Orifice Controls 0.01 cfs @ 5.78 fps) econdary OutFlow Max=2.17 cfs @ 12.04 hrs HW=2,761.69' (Free Discharge) Sharp-Crested Rectangular Weir (Weir Controls 2.17 cfs @ 1.43 fps) 1=Culvert (Passes 2.17 cfs of 6.60 cfs potential flow) 3=13road-Crested Rectangular Weir (Controls 0.00 cfs) Best Buy Wet Basin-Sand Filter Drainage Area 1 v4 Type// 24-hr 100yr Rainfall=7.46" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 0 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Pond Pond: Pond Hydrograph " -- - _ - -- -- --- - - - --- -- '. ' 1lnf1bW''Area-6081; 18 - - -e - - I - -- t--- 17 14.33 ' cfs 'Pek- ? -- ?5? 15 14.3 2 da Storage 16, -1---- f 14 13 -; - 12 v 10 `p 8 - ___ 7 g 5 - 4 - I I I I -I I I 3 2 Outflow aIN Inflow Primary Secondary 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 Time (hours) Best Buy Wet Basin-Sand Filter Drainage Area 1 v4 Type 11 24-hr 100yr Rainfall=7.46" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 02007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Summary for Pond Pond: Pond Inflow Area = 60,814 sf, 94.60% Impervious, Inflow Depth = 6.98" for 100yr event Inflow = 16.52 cfs @ 11.93 hrs, Volume= 35,385 cf Outflow = 14.33 cfs @ 11.96 hrs, Volume= 22,741 cf, Atten= 13%, Lag= 1.7 min Primary = 0.01 cfs @ 11.96 hrs, Volume= 1,243 cf Secondary = 14.32 cfs @ 11.96 hrs, Volume= 21,498 cf Routing by Stor-Ind method, Time Span= 0.00-60.00 hrs, dt= 0.01 hrs Peak Elev= 2,762.15'@ 11.96 hrs Surf.Area= 4,692 sf Storage= 16,417 cf Plug-Flow detention time= 272.7 min calculated for 22,738 cf (64% of inflow) Center-of-Mass det. time= 168.9 min ( 915.3 - 746.4 ) Volume Invert Avail.Storage Storage Description #1 2,756.00' 18,1 35 cf Custom Stage Data (Irregular) Listed below (Recalc) Elevation Su rf.Area Perim. Inc.Store Cum.Store Wet.Area (feet) (sq-ft) (feet) (cubic-feet) (cubic-feet) (sq-ft) 2,756.00 508 176.0 0 0 508 2,757.00 1,148 240.0 807 807 2,637 2,758.00 1,914 268.0 1,515 2,321 3,797 2,759.00 2,754 291.0 2,321 4,643 4,858 2,760.00 3,456 310.0 3,098 7,741 5,815 2,760.25 3,588 314.0 880 8,621 6,028 2,760.50 3,722 318.0 914 9,535 6,244 2,761.00 3,995 326.0 1,929 11,464 6,685 2,761.50 4,280 335.0 2,068 13,532 7,186 2,762.00 4,572 343.0 2,213 15,745 7,650 2,762.50 4,991 398.0 2,390 18,135 10,898 Device Routing Invert Outlet Devices #1 Device 2 2,755.70' 24.00" x 142.0' long Culvert CPP, square edge headwall, Ke= 0.500 Outlet Invert= 2,755.36' S= 0.0024T Cc= 0.900 n= 0.010 PVC, smooth interior #2 Secondary 2,761.50' 8.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s) #3 Secondary 2,762.00' 15.0' long x 12.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.57 2.62 2.70 2.67 2.66 2.67 2.66 2.64 #4 Primary 2,760.25' 6.00" x 28.0' long Culvert CPP, square edge headwall, Ke= 0.500 Outlet Invert= 2,759.75' S= 0.01797' Cc= 0.900 n= 0.010 PVC, smooth interior #5 Device 4 2,759.25' 0.50" Horiz. Orifice/Grate Limited to weir flow C= 0.600 Best Buy Wet Basin-Sand Filter Drainage Area 1 v4 Type// 24-hr 100yr Rainfall=7.46" Prepared by HydroCAD SAMPLER 1-800-927-7246 www.hydrocad.net Printed 11/14/2008 HydroCAD® 8.50 SAMPLER s/n 026033 © 2007 HydroCAD Software Solutions LLC This report was prepared with the free HydroCAD SAMPLER, which is licensed for evaluation and educational use only. For actual design or modeling applications you must use a full version of HydroCAD which may be purchased at www.hydrocad.net. Full programs also include complete printed documentation, technical support, training materials, and additional features which are essential for actual design work. Primary OutFlow Max=0.01 cfs @ 11.96 hrs HW=2,762.14' (Free Discharge) t- Culvert (Passes 0.01 cfs of 1.21 cfs potential flow) 5=0rifice/Grate (Orifice Controls 0.01 cfs @ 6.63 fps) econdary OutFlow Max=14.25 cfs @ 11.96 hrs HW=2,762.14' (Free Discharge) Sharp-Crested Rectangular Weir (Passes 12.14 cfs of 13.30 cfs potential flow) 1=Culvert (inlet Controls 12.14 cfs @ 3.86 fps) 3=Broad-Crested Rectangular Weir (Weir Controls 2.11 cfs @ 0.98 fps)