HomeMy WebLinkAbout20140957 Ver 2_Attachment 2_WV DEP Order to Cease Rover Pipeline_20170818Attachment 2
dep
west vlrginla department of environmental protection
Environmental Enforcement
6015" Street SE
Charleston, WV 25304
Telephone: (304) 926-0470 Fax: (304) 926-0488
Rover Pipeline LLC
Attn: Buffy Thomason
1300 Main Street
Houston, TX 77002
Jim Justice, Governor
Austin Caperton, Cabinet Secretary
www.dep.wv.gov
July 17, 2017
CERTIFIED RETURN RECEIPT REQUESTED
91 7199 9991 7037 0933 8497
Enclosed is Order No. 8749 dated July 17, 2017. This Order is issued to Rover Pipeline
LLC by the director of the Division of Water and Waste Management under the authority of
Chapter 22, Article 11, Section 12 of the Code of West Virginia. This Order contains
notification of the right of appeal under the provisions of Chapter 22, Article 11, Section 21.
/... .,..r
r :.. /
cc: Scott G. Mandirola, Director, DWWM (via e-mail)
Yogesh Patel, Asst. Director, DWWM/Permits (via e-mail)
Robin C. Dolly, Assistant Chief Inspector, EE/WW (via e-mail)
David C. Simmons, Assistant Chief Inspector, EE (via e-mail)
Christopher M. Gatens, Enforcement Hearing Officer, EE (via e-mail)
Debora J. Peters, Environmental Resources Specialist, EE (via e-mail)
Laura McGee, Environmental Resources Specialist (via e-mail)
John Hendley, Environmental Inspector Supervisor, EE/WW (via e-mail)
Tim Casto, Environmental Inspector, EE/WW (via e-mail)
Shyrel Moellendick, MSSS, EE (via e-mail)
Lisa Trakis, US EPA, Region III (via e-mail)
Promoting a healthy environment.
dep
west virginla department of environmental protection
Division of Water and Waste Management Jim Justice, Governor
601 5" Street SE Austin Caperton, Cabinet Secretary
Charleston, WV 25304 www.dep.wv.gov
Phone: (304) 926-0470
Fax: (304) 926-0488
ORDER
ISSUED UNDER THE
WATER POLLUTION CONTROL ACT
WEST VIRGINIA CODE, CHAPTER 22, ARTICLE 11
TO: Rover Pipeline LLC DATE: July 17, 2017
Attn: Buffy Thomason
1300 Main Street ORDER NO.: 8749
Houston, TX 77002
The following findings are made and Order issued to Rover Pipeline LLC pursuant to the
authority vested in the Director of the Division of Water and Waste Management under Chapter
22, Article 11, Section 1 et seq. of the Code of West Virginia.
FINDINGS OF FACT
In support of this Order, the Director hereby finds the following:
Rover Pipeline LLC is conducting land disturbance activity in Doddridge and Tyler
Counties, West Virginia. Rover Pipeline LLC was issued Water Pollution Control Permit
No. WV0116815, Registration No. VIVR310726 on December 15, 2016.
2. On April 26, 2017, West Virginia Department of Environmental Protection (WVDEP)
personnel conducted an inspection of the facility. During the inspection, violations of the
following sections of WV Legislative Rules and the permit were observed and
documented:
a. 47CSR2 Section 3.2.b - Rover Pipeline LLC caused conditions not allowable in
waters of the State by creating sediment deposits on the bottom of Eibscamp Run and
the Unnamed Tributary (UNT) of Buckeye Creek.
b. Section GA.e.2 — The Permittee failed to properly implement controls. Specifically,
silt fence and perimeter controls at the compressor site were improperly
instal led/maintained.
c. Section D.1- The Permittee failed to operate and maintain all erosion control devices
at the compressor site.
Promoting a healthy environment.
Company/Individual Order
Page 2
d. Section G.4.c - The Permittee failed to modify its Storm Water Pollution Prevention
Plan (SWPPP) when the SWPPP proved to be ineffective for achieving the general
objectives of controlling pollutants in storm water discharges at the compressor site.
e. Section B - The Permittee failed to comply with the approved SWPPP. Several
erosion control devices were not in place on the pipeline right of way as detailed by
the SWPPP.
f. Section G.4.e.2.A.ii j - The Permittee failed to prevent sediment -laden water from
leaving the site without going through an appropriate device. Off site and in stream
sediment deposits were noted on the compressor site as well as the pipeline right of
way.
As a result of the aforementioned violations, Notice of Violation (NOV) No. W 17-09-
0 1 9-TJC was issued to Rover Pipeline LLC.
3. On May 24, 2017, WVDEP personnel conducted an inspection of the facility. During the
inspection, violations of the following sections of WV Legislative Rules and the permit
were observed and documented:
a. 47CSR2 Section 3.2.b- Rover Pipeline LLC caused conditions not allowable in
waters of the State by creating sediment deposits on the bottom of Eibscamp Run
and the UNT of Buckeye Creek.
b. Section GA.e.2 - The Permittee failed to properly implement controls.
Specifically, silt fence/controls were improperly installed on the Sherwood
Lateral Pipeline, most notably at the pipeline crossing at the UNT of Buckeye
Creek.
c. Section D.1 - The Permittee failed to operate and maintain all erosion control
devices at the compressor site.
d. Section G.4.c - The Permittee failed to modify its SWPPP when the SWPPP
proved to be ineffective for achieving the general objectives of controlling
pollutants in storm water discharges at the compressor site.
e. Section B - The Permittee failed to comply with the approved SWPPP. Erosion
control devices at the outlets of water bars were not in place on the pipeline right
of way as detailed by the SWPPP.
f. Section GA.e.2.A.ii j - The Permittee failed to prevent sediment -laden water from
leaving the site without going through an appropriate device. Off site and in
stream sediment deposits were noted on the compressor site as well as the
pipeline right of way.
As a result of the aforementioned violations, NOV No. W 17-09-028-TJC was issued to
Rover Pipeline LLC.
4. On June 2 and 6, 2017, WVDEP personnel conducted an inspection of the facility.
During the inspection, violations of the following sections of WV Legislative Rules and
the permit were observed and documented:
a. 47CSR2 Section 3.2.b- Rover Pipeline LLC caused conditions not allowable in
waters of the State by creating sediment deposits on the bottom of UNT of
Company/Individual Order
Page 3
Jockeycamp Run, UNT of Morgans Run, UNT of Nutter Fork and ephemeral
UNT of Nutter Fork.
b. Section GA.e.2 - The Permittee failed to properly implement controls.
Specifically, silt fence was improperly installed on the Sherwood Lateral Pipeline
from Rock Run to Elija Smith Road and west of Nutter Fork. Water bars were
improperly installed throughout the inspected area. Water bar outlets lacked
proper treatment throughout the inspected area. Bridges were improperly installed
at Rock Run and the UNT of Morgans Run. No perimeter controls were in place
from Access 10-B to 470+00.
c. Section D.1 - The Permittee failed to operate and maintain all erosion control
devices. Specifically, areas of silt fence were in need of maintenance throughout
the inspected area. Water bars were damaged and/or eroded throughout the
inspected area.
d. Section B - The Permittee failed to comply with the approved SWPPP. Erosion
control devices at the outlets of water bars were not in place on the Sherwood
Lateral pipeline right of way throughout the inspected area as detailed by the
SWPPP. Controls were improperly installed from Rock Run to Elija Smith Road
and west of Nutter Fork. No perimeter controls were in place from access 10-B to
470+00.
e. Section GA.e.2.A.ii j - The Permittee failed to prevent sediment -laden water from
leaving the site without going through an appropriate device. Off site and in
stream sediment deposits were noted at the UNT of Jockeycamp Run, UNT of
Morgans Run, UNT of Nutter Fork, ephemeral UNT of Nutter Fork 100+00 and
84+00.
As a result of the aforementioned violations, NOV No. W 17-09-030-TJC was issued to
Rover Pipeline LLC.
5. On July 12, 2017, WVDEP personnel conducted an inspection of the facility. During the
inspection, violations of the following sections of WV Legislative Rules and the permit
were observed and documented:
a. 47CSR2 Section 3.2.b- Rover Pipeline LLC caused conditions not allowable in
waters of the State by creating sediment deposits at the following eight (8)
locations: England's Run, UNT of Buckeye Creek, UNT of Jockeycamp Run,
UNT of Morgan's Run, ephemeral UNT of Morgan's Run, UNT of Rock Run,
UNT of Nutter Fork, and Nutter Fork.
b. 47CSR2 Section 3.2.a- Rover Pipeline LLC caused conditions not allowable in
waters of the State by creating distinctly visible settleable solids in the UNT of
Buckeye Creek and the UNT of Rock Run.
c. Section GA.e.2 - The Permittee failed to properly implement controls.
Specifically, sheet flow Best Management Practices (BMPs) were being utilized
in areas of concentrated flow.
d. Section D.1 - The Permittee failed to operate and maintain all erosion control
devices. Specifically, areas of silt fence, filter sock, and water bar sumps were in
need of maintenance throughout the inspected area.
e. Section B - The Permittee failed to comply with the approved SWPPP.
Specifically, multiple water bars throughout the inspected area were not installed
Company/Individual Order
Page 4
as designed in the SWPPP. The storm water that is handled by the water bars was
not being diverted off the Limits of Disturbance (LOD), resulting in concentrated
flow traveling down-slope and overwhelming sheet flow BMPs at the base of the
hill.
f. Section GA.e.2.A.ii j - The Permittee failed to prevent sediment -laden water from
leaving the site without going through an appropriate device. Offsite and/or in
stream sediment deposits were noted in the following locations: Camp Mistake
Run, England's Run, UNT of Buckeye Creek, UNT of Jockeycamp Run, UNT of
Morgan's Run, Ephemeral UNT of Morgan's Run, UNT of Rock Run, UNT of
Nutter Fork, and Nutter Fork.
g. Section GA.e. LD - The Permittee failed to provide an adequate stone access
entrance/exit to reduce the tracking of sediment onto Morgan's Run Road.
h. Section G.4.e.2.D.i — The Permittee failed to inspect and clean debris from
Morgan's Run Road.
As a result of the aforementioned violations, NOV No. W 17-09-038-TJC was issued to
Rover Pipeline LLC.
ORDER FOR COMPLIANCE
And now, this day of July 17, 2017, Rover Pipeline LLC is hereby ORDERED by the
Director as follows:
1. Rover Pipeline LLC shall immediately cease & desist any further land development
activity until such time when compliance with the terms and conditions of its permit and
all pertinent laws and rules is achieved. Rover Pipeline LLC shall contact WVDEP to
arrange an inspection prior to restarting development activities. Environmental
Enforcement may be contacted at:
WVDEP Environmental Inspector Supervisor
Construction Stormwater Environmental Enforcement
1159 Nick Rahall Greenway
Fayetteville, WV 25840
(304) 574-4471
2. Within twenty (20) days of the effective date of this Order, Rover Pipeline LLC shall
submit for approval a proposed plan of corrective action and schedule, outlining action
items and completion dates for how and when Rover Pipeline LLC will achieve
compliance with the terms and conditions of its permit and all pertinent laws and rules.
The plan of corrective action shall make reference to Order No. 8749. The plan of
corrective action shall be submitted to:
Chief Inspector
Environmental Enforcement - Mail Code #031328
WVDEP
60157th Street SE
Charleston, WV 25304
Company/Individual Order
Page 5
Upon approval, the plan of corrective action and schedule shall be incorporated into and
become part of this Order, as if fully set forth herein. Failure to submit an approvable
plan of corrective action and schedule or failure to adhere to the approved schedule is a
violation of this Order.
3. Rover Pipeline LLC shall immediately install and maintain necessary stone water and
sediment/erosion control devices to prevent the release of sediment -laden water into
waters of the State. All disturbed areas shall immediately be temporarily mulched until
such time when compliance with the terms and conditions of its permit and all pertinent
laws and rules is achieved, an approvable plan of correction action is submitted in
accordance with Order For Compliance Item No. Two (2) of this Order, and land
development activity resumes in accordance with Order For Compliance No. One (1) of
this Order.
OTHER PROVISIONS
1. Compliance with the terms and conditions of this Order shall not in any way be construed
as relieving Rover Pipeline LLC of the obligation to comply with any applicable law,
permit, other order, or any other requirement otherwise applicable. Violations of the
terms and conditions of this Order may subject Rover Pipeline LLC to additional
enforcement action in accordance with the applicable law.
2. The provisions of this Order are severable and should a court or board of competent
jurisdiction declare any provisions to be invalid or unenforceable, all other provisions
shall remain in full force and effect.
3. This Order is binding on Rover Pipeline LLC, its successors and assigns.
4. This Order shall terminate upon Rover Pipeline LLC's notification of full compliance
with the "Order for Compliance" and verification of this notification by W VDEP.
RIGHT OF APPEAL
Notice is hereby given of your right to appeal the terms and conditions of this Order
which you are aggrieved to the Environmental Quality Board by filing a NOTICE of APPEAL
on the form prescribed by such Board, in accordance with the provisions of Chapter 22, Article
11, Section 21 of the Code of West Virginia within thirty (30) days after receipt of this Order.
This Order shall become effective upon receipt.
S ott G. Mandirola, Director
Division of Water and Waste Management
ROVER PIPELINE LLC, WVR310726. Sherwood Lat and Compressor & CGT Lat and Meter, 4/26/2017
Maintenance issues a
Sherwood Compressor.
ting of filter sock) at
ROVER PIPELINE
Lat and Meter, 4/26/2017
Maintenance issues at Sherwood Compressor.
ROVER PIPELINE I.1.C, WVR310726, Sherwood Lat and
F
d�
Improperly installed
L.�
y �.a '•
ressor & CGT Lat and Meter, 4/26/2017
section of filter
0
Maintenance issues at Sherwood Compressor.
Compressor.
f :7
r'
n..
r
section of filter
0
Maintenance issues at Sherwood Compressor.
Compressor.
ROVER PIPELINE
it and Meter, 4/26/2017
Sediment leaving site on the western side of compressor pad.
One of the areas at Sherwood Compressor where triple stack filter sock was used in concentrated flow that
allowed sediment laden water to leave site.
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and
=I=
& CGT Lat and Meter, 4/26/2017
Sediment leaving site at Sherwood Compressor.
W
Sediment leaving site at Sherwood Compressor.
I:Z6IV.: ' IU
& CGT Lat and Meter, 4/26/2017
Sediment deposits in Eibscamp Run that have left site (Sherwood Compressor).
Sediment deposits in Eibscamp Run that have left site (Sherwood Compressor).
Ic OITAa"aaIWWoO
1 and Meter, 4/26/2017
Sediment leaving site behind barn at Sherwood Compressor site.
Fill slope lacking stabilization with erosion gullies (Sherwood Compressor).
MIG
-r, 4/26/2017
Areas of disturbed soil lacking E&S controls on Sherwood Lateral pipeline ROW.
Areas of disturbed soil lacking E&S controls on Sherwood Lateral pipeline ROW.
1.011FFAII:,91,
Ephemeral str
-r, 4/26/2017
ttrols in place.
Ephemeral stream that has had equipment in channel. Soil has been disturbed with no E&S controls in place.
I &SITA 21 A 9 190 INN 91
& CGT Lat and Meter, 4/26/2017
UNT of Buckeye Creek (Sherwood Lateral Pipeline ROW). Disturbed soil with no controls in place and
sediment deposits in stream.
UNT of Buckeye Creek (Sherwood Lateral Pipeline ROW). Disturbed soil with no controls in place and
sediment deposits in stream.
ROVER PI]
!ter, 5/24/17
Portion of filter sock downslope of compressor site near Eibscamp Run that is improperly installed.
_ r
Silt fence on the cstcrn 11ci mictct of the compressot site that needs to be extended.
ROVER PIPELINE
& CGT Lat and Meter, 5/24/17
Perimeter controls below access road on compressor site.
ROVER PIPELINE LLC. W V R310726, Sherwood Lat and
A 1 u'/•.
I^ fu A
Perimeter
& CGT Lat and Meter, 5/24/17
maintenance.
Offsite sediment deposits below upper picture.
ROVER PIPELINE
& CGT Lat and Meter, 5/24/17
Area below compressor access
concentrated flow is being treated with sheet flow controls. This area
is consistently being overwhelmed which is causing sediment laden water to leave the site.
Area below compressor access road where concentrated flow is being treated with sheet flow controls. This area
is consistently being overwhelmed which is causing sediment laden water to leave the site.
TSIVff:'I
;ter, 5/24/17
Area below access road near compressor site where construction activity has gone past LOD and compromised
controls.
Area below access road near compressor site where construction activity has gone past LOD and compromised
controls.
ROVER PI1
!ter, 5/24/17
Confluence of Eibscamp Run and Meathouse Fork showing sediment plume from compressor site as well as
Eibscamp Road Improvement project.
Confluence
water in Eibscamp Run.
ig into muddy
ROVER PIl
;ter, 5/24/17
Head of Eibscamp Run near compressor site showing muddy water / sediment deposits.
ROVER I'Il
Water
Ser. 5/24/17
fe site.
44
4
Water bar outlets that have no treatment, which is causing sediment laden water to leave site. The above
pictures are representative of all water bars for the portion of the pipeline inspected.
ROVER PI]
Improperly installed controls on Sherwood Lateral pipeline.
.ter, 5/24/17
Improperly installed controls on Sherwood Lateral pipeline. Bottom picture is at stream crossing of LINT of
Buckeye Creek.
I:DIVAN
& CGT Lat and Meter, 5/24/17
Overview of pipeline stream crossing of UNT of Buckeye Creek. Sheet flow controls being used in
concentrated flow of ephemeral stream causing sediment deposits in stream. Silt fence being utilized in place of
super silt fence.
Overview
used in
concentrated flow of ephemeral stream causing sediment deposits in stream. Silt fence being utilized in place of
super silt fence.
ROVER PIPELINE
& CGT Lat and Meter, 5/24/17
upstream of pipeline crossing of UNT of Buckeye Creek.
Stream channel downstream of pipeline crossing of UNT of Buckeye Creek showing sediment deposits.
ROVER PIPELINE
& CGT Lat and Meter. 6/2 & 6/6/2017
Water bars with no treatment at outlets.
Water bars with no treatment at outlets.
a'
Water bars with no treatment at outlets.
Water bars with no treatment at outlets.
ROVER PIPELINE LLC, WVR310726. Sherwood Lat and
Lat and Meter, 6/2 & 6/6/2017
_. ,y x �aJ G F ✓ DR ,a -
xe-
h r Y
y z
Water bar outlet that goes into ephemeral stream that leads off site with no controls in place.
Water bar with no treatment at outlets.
ROVER PIPELINE
and Meter, 6/2 & 6/6/2017
r =.71
7-1
Water bars that have been damaged and were not maintained. Several areas on the project showed similar
damage with no repairs even though it was evident that the damage had taken place several days prior to this
inspection.
Water bars that have been damaged and were not maintained. Several areas on the project showed similar
damage with no repairs even though it was evident that the damage had taken place several days prior to this
inspection.
ROVER PIPELINE
6/2 & 6/6/2017
Pipeline section to the east of Englands Run where water bars were installed improperly which caused
concentrated flow to be treated by sheet flow BMP's at the bottom of the hill near the receiving stream. An
Pipeline
controls.
dch caused
concentrated flow to be treated by sheet flow BMP's at the bottom of the hill near the receiving stream. An
offsite ephemeral stream flows onto ROW which is also treated at pictured controls.
ROVER PIPELINE
& CGT Lat and Meter, 6/2 & 6/6/2017
Offsite sediment deposits at 100+00 as a result of poor maintenance on controls.
ROVER PIPEL
Sediment deposits in ephemeral UNT of Jockeycamp Run near 200+00.
6/2 & 6/6/2017
ROVER PIPEL
Sediment de
Sediment
overwhelmed due to improper water bar installation.
6/2 & 6/6/2017
,ntrols being
introls being
overwhelmed due to improper water bar installation.
ROVER PIPELINE LLC, WVR110726, Sherwood Lat and
Sediment deposits in UNT of Morgans Run
& CGT Lat and Meter, 6/2 & 6/6/2017
of previously pictured bridge.
Sediment deposits in UNT of Morgans Run downstream of previously pictured bridge. Picture is taken below
LOD.
f.ZSi9:):49
6/2 & 6/6/2017
...
UNT of Nutter Fork with sediment deposits. Controls not in place as indicated in SWPPP.
ROVER PIPELINE
6/2 & 6/6/2017
ROVER PIPELINE
Ephemeral U
MI Z -r TIST ►IIM
ntrated flow.
Ephemeral UNT of Nutter Fork with sediment deposits. Sheet flow BMP being used in concentrated flow.
ROVER PIPELINE
6/2 & 6/6/2017
y
Improperly installed bridge on Rock Run, which is allowing sediment to get past control.
Improperly installed bridge on Rock Run, which is allowing sediment to get past control.
r
_e
to
�.. :r ..
ROVER PIPELINE
Sherwood Lat and Comnressor & CGT I.at and Meter 6/2 & 6/6/2017
Areas of pipeline with no controls in place.
Areas of pipeline with no controls in place.
ROVER PIPELINE
Sherwood Lat and Compressor & CGT Lat and Meter. 6/2 & 6/6/2017
Improperly installed controls.
Improperly installed controls.
a
ROVER PIPELINE
WVR31
Concentrated flow from water
6/2 & 6/6/2017
near Rock Run.
ti s ?
,i •"' �� }'',:q
i
,c
Concentrated flow from water bar that is following silt fence trench to the bottom of the hill near Rock Run.
ROVER PIPELINE
Concentrated f
Fork.
6/2 & 6/6/2017
az UNT Nutter
Concentrated flow from water bar that is following silt fence trench to the bottom of the hill near UNT Nutter
Fork.
ROVER PIPELINE
Silt fence in need of maintenance near UNT of Morgans Run.
Silt Cence in need of maintenance near UNT of Morgans Run.
6/2 & 6/6/2017
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
I:AY.I/
indicated in SWPPP.
as
ROW with pipe trench near UNT of Buckeye creek. Water bars not in place and functioning as
indicated in SWPPP.
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
O
�%* I
�!;`-ll ��]�.. .'.: fin•., a\P ..
ROW near Morgan's Run showing lack of effective water bars, which caused storm water to
follow pipe trench / ROW to the base of the hill.
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
Area near Engla
Area near C
bars.
i effective water
silt fence.
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
Sheet flc
,ve Creek
UNT of
'v0.
n
Sheet flow BMPs in need of maintenance and being used in concentrated flow areas near UNT of
Buckeye Creek.
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
Sheet flow BMPs in need
and being used in concentrated flow areas near UNT of
Buckeye Creek.
BMPs in need of maintenance near UNT of Buckeye Creek.
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
BMPs at water bar outlet near
BMPs at water
Mistake Run in need of maintenance.
of maintenance.
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
UNT of Buckeye Creek.
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
Kf �.
� e8 ;�. i ♦ �yt y �4
T .
� Y f
�
2L u
"
UNT of Morgan's Run (ephemeral near HDD pad).
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
Area unslone of UNT of Eneland's Run.
r
r -
J 4
t
y
Area unslone of UNT of Eneland's Run.
r -
J 4
UNT of England's Run.
ROVER PIPELINE LLC, VWR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
UNT of Englan
notebook.
i") indicated by
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
Sf
Sediment lades
damaging controls.
n.
centrated flow
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
Sediment laden water leaving the site and migrating toward receiving stream adjacent to UNT of
Jockey Camp Run.
Sediment laden water leaving the site
nd migrating toward receiving stream adjacent to UNT of
Jockey Camp Run.
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
Sedir
Sedir
Run.
Run.
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
Area adjacent to UNT of Rock Camp Run.
f „^
"q
UNT of Rock Run - Sediment laden water flowing sub surface prior to entering receiving stream.
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
Sediment deposits (rollers) in Nutter Fork.
Offsite sediment deposits adjacent to Nutter Fork.
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
Area above offsite sediment deposits near "\Utter Fork
Offsite sediment deposits near Nutter Fork.
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
Damaged bridge at UNT of Nutter Fork.
♦Yi ai 1 �
1\
y y
_-•,� � �.f,�e a ,;. �,.
•; r a �
Damaged bridge at UNT of Nutter Fork.
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
f:R7iift� '
Offsite sediment deposits at UNT of Nutter Fork.
to leave site.
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
Area upslope of offsite sediment deposits at Camp Mistake Run.
ROVER PIPELINE LLC, WVR310726, Sherwood Lat and Compressor & CGT Lat and Meter,
7/12/2017
entrance causin mud to be tracked out onto Mor an's Run Road
`1
:gym.
I
Unstable construction entrance causing mud to be tracked out onto Morgan's Run Road.