Loading...
HomeMy WebLinkAboutC601 LANDSCAPE PLAN ENLARGEMENTCITY OF STATESVILLE �v > SITE J �O m VICINITY MAP NTS EXISTING 1 + ORNAMENTAL TREE AND 3 EXISTING SHADE TREES (2"D5H OR GREATER) PER EVERY 100 LF. TO COUNT 9� TOWARD TYPE A BUFFER REQUIREMENTS. STATE OF NORTH CAROLINA <�L (40 PTO MIN.) IF ANY OF REQUIRED TREES DB 1062 PG 1527 PROVIDE TEMPORARY IRRIGATION O IN BUFFER YARD ARE DAMAGED OR DIE (ZONED: CU -6 B-5) UNTIL 50D 16 FULLY ESTABLISHED DURING CONSTRUCTION, OWNER WILL VACANT REPLACE WITH NEW TREES TO MEET THE REBAR LIMITS OF OOD CITY OF STATESVILLE UDO REQUIREMENTS. FOUND N04'40'S3'E 784.85' r. j_ 8' TYPE A BUFFER - — x.140 REAR SETBACK— — I SEED AREA 936 SEED AREA 914 I� 935 gS4 SOD %f SEED AREA / ss -32' STAND—OFF ss= DISTANCE (TYP.) SOD WOODEN FENCE DUMPSTER ENCLOSURE - - - FUTURE pc \ I EXPANSION 1 I I I � SOD 1 EX/ST/NG WOODED AREA TO I, REMAIN I' f 1I 30,00 - LF R" DIPS IC2 23 71 -FT II IIII CJ 1 \ _811GENERATOR 4�4 0 z 10 ' STAFF PARKINGLC2 =� SEED GENERATOR \ I i (58,SPACES) 19 ® AREA — �— GEED AREA (ALL \ -S I r LANDSCAPE GE / UGE USE— -U AC AC - - 1 ISLANDS, TYP.) I TRANS. r so - I oocp000&� J 60' EASEMENT I PROPOSED SEED AREA REBAR S03 7"E FOUND 133.98' RAPE MYRTLE(TYP) 1 w N I I I IRON PIPE FOUND —SS—� 1 —ss —ss--- � oa o SEED AREA IIII � I I o SEED AREA EMERGENCY (� 111'11 r17 MIS O ° �� ■v o■ o•_ o v • LIMITS OF DRIP IRRIGATION J o �J 0 mx 2 1 SEED° C m O i AREA C]o 945° Cl 27 ! I .Y D DRp�R�D- RD- f\ ° Io 0 1 I I TIE (7 I Elo J L .. - o- w AC - v 0 — OPOSED SEED_ AREA C G UILDIN ICA I I ® °®� IT o o , It w cn ®oA AXWQ EE10�0 14 LE LLL w z- 25 1 EX/ST/NG WOODED AREA TO I (D - — — / ° ° ° ° ° ° ° / I ,N,• P� 1 REMAIN I m DW °T ° ° o ° ° ° ° ° ° ° ImF ° F ° Q ° ° ° ° ° p CK -� o PIN.•4724571621 — VM STATE OF NORTH CAROLINA 63 .°w� ' es o • MOUNT IRRIGATION i I 0 \ I DS 1062 PG 1527 CONTROLLER ON INSIDE 5EED 0 0 (ZONED: CU -6 3-5) � P' I VACANT WALL. COORDINATE I AREA �o s 0 CK L LOCATION WITH ARCHITECT _ DONA LISBETH WILLIAMS I —944 il \ DB 2240 PG 2094 UP (ZONED: R-20) I � 78 Iml MEN 1 p LIMITS OF DRIP IRRIGATION RF XPAN510N 1 �26 ---- RF 78 \ \ SEE[ EXISTING 1+ ORNAMENTAL TREE AND 3 \ ARD EXISTING SHADE TREES (2 DBH OR F F �4 GREATER) PER EVERY 100 LF. TO COUNT 943— \ \ / TOWARD TYPE A BUFFER REQUIREMENTS. (40 PTO MIN.) IF ANY OF REQUIRED TREES I�� 5EED AREA IN BUFFER YARD ARE DAMAGED OR DIE I �� 0 5EED AREA DURING CONSTRUCTION, OWNER WILL L J REPLACE WITH NEW TREES TO MEET THE o �y (^^I CITY OF STATESVILLE LIDO REQUIREMENTS. \ \ — — — — — — — — — — � 1 LC3 9 SHRUB PLANTING 27 1 \ C503 adw 0 1 MULCHLINE 3 (TYP,) 0 8 TREE PLANTING 5EED AREA � BERM (TOPSOIL/ QS C503 QS � I UNSUITABLE SOIL) 50' O.C. I c9 Vj � bEKM (TOPSOIL/ IN UNSUITABLE SOIL) °Tc_ 1 IN 3ERM (T0P5UIL_/ IN IN IN 5EED AREA — — — 5 — — IN — — �NLTA�1-E X011-) — 3 — — — — — — 3 — 25' FRONT SETBACK — — — — 3 — — — — - 3 NT c' -I 18 --945-��e * 5EED AREA 60 E�—E E E E . E E E- - ti u T PROPOSED R W /u off/u OH/ off/u off/u off off/u H/ o i/u off i, off/u uti a —off/u o+/u off/u, off/u�off/u o /u off/u- N e� 5EED AREA 945 FES 37 - o a EX. SOP I- T T T T i - T T T T T T T o � EXIST. PROPERTY LINE GEED SITE ALONG ROAD FRONTAGE TO WITHIN 6' OF EOP OR DENUDED LIMITS,' CP /N PAVEMENT EX. EOP WHICHEVER 15 GREATER (TYP.) BRISTOL DRIVE -SR 1358 WO IWOI WO W a (NO RECORDED R/W FOUND) I I I (ZONED: R-20) RESIDENTIAL (ZONED: R-20) RESIDENTIAL PLANT MATERIAL 1. MINIMUM TREE 51ZE AT PLANTING 16 2" CALIPER AND 6' TALL FOR 51NGLE-STEM TREES. ALL MULTI -STEM PLANTS MUST BE TREE FORM, MAXIMUM 3 TO 5 TRUNKS, AND MINIMUM 10' TALL. 2. ALL NEW TREES MUST HAVE STRAIGHT TRUNKS WITH STRONG CENTRAL LEADERS INTACT TO THE TOP OF THE CROWN UNLESS MULTI -STEM TREES ARE SPECIFIED. ALL TREES SHALL BE TYPICAL OF THEIR SPECIES AND VARIETY, HAVE NORMAL GROWTH HABITS, HAVE WELL- DEVELOPED BRANCHES, BE VIGOROUS AND HAVE FIBROUS ROOT SYSTEMS, TREES WITH CO -DOMINANT BRANCHING WILL NOT BE ACCEPTED. TREES THAT HAVE BEEN SHEARED, TOPPED OR CUT BACK TO MULTIPLY THE BRANCHING STRUCTURE WILL NOT BE ACCEPTED. TREES SHALL BE FREE OF ABRASIONS, DAMAGE, DISEASE, PESTS AND CRACKS. ALL PRUNING CUTS GREATER THAN I° DIAMETER SHALL HAVE CALLUS TISSUE FORMED PRIOR TO PLANTING. NO PRUNING CUT ON THE TRUNK SHALL BE MORE THAN ONE-HALF THE DIAMETER OF THE CENTRAL LEADER AT THE HEIGHT WHERE THE CUT WA6 MADE. ROOT FLARES SHALL BE LOCATED AT GRADE. TREES WITH MORE THAN 2" OF SOIL COVERING THE ROOT BALL/FLARE FROM WILL NOT BE ACCEPTED. 3. SIZE OF PLANTS, SPREAD OF ROOTS AND 61ZE OF BALLS SHALL BE IN ACCORDANCE WITH AN61 Z60.1 (LATEST EDITION) AS PUBLISHED BY THE AMERICAN NURSERY b LANDSCAPE A550CIATION. 4. ALL TREES OF A PARTICULAR SPECIES AND VARIETY SHALL BE UNIFORM IN 61ZE AND CONFIGURATION. PLANTING REQUIREMENTS 5. PLASTIC H06E PARTS WILL NOT BE ACCEPTED FOR TREE STAKING. SEE DETAILS AND SPECIFICATIONS FOR APPROVED STAKING METHOD/MATERIALS. 6. ALL STRAPPING, AND TOP I OF WIRE BASKET AND BURLAP MUST BE CUT AWAY AND REMOVED FROM ROOT BALL WHEN PLANTING. 7. FOR NEW PLANTING AREAS, REMOVE ALL PAVEMENT, GRAVEL SUB -BASE AND CONSTRUCTION DEBRIS; REMOVE COMPACTED 501L AND ADD 24" NEW TOP501L, OR TILL AND AMEND THE TOP 24" OF EX15TING 501L TO MEET TOPSOIL/ PLANTING MIX 6TANDARD5 FOR TREES. 8. ALL SAUCERS SHALL BE SOAKED WITH WATER AND MULCHED IMMEDIATELY FOLLOWING PLANTING. 9. THE TOP OF ALL ROOT BALLS FOR SHRUBS 6 GROUNDCOVERS SHALL BEAR THE SAME RELATIONSHIP TO FINISHED GRADE, A5 BORN TO PREVIOUS GROWING CONDITIONS. 10. ALL ROOT BALLS REMOVED FROM CONTAINERS SHALL BE SCARIFIED PRIOR TO BACKFILLING. 11. MULCH A MINIMUM 4 FOOT AREA AROUND EACH TREE AND - MULCH A CONTINUOUS AREA AROUND ALL SHRUB BEDS, A6 INDICATED ON THE PLAN. MULCH SHALL BE 3-4" THICK. MULCH AROUND TREES SHALL BE TAPERED TOWARD TRUNK 50 THAT NO MORE THAN 2" 15 PLACED AT TREE TRUNK A5 SHOWN ON DETAIL. SEE SPECIFICATIONS FOR TYPE. UTILITY ISSUES 12. LARGE MATURING TREES MAY NOT BE PLANTED WITHIN 25' OF OVERHEAD POWER DISTRIBUTION OR TRAN6MI6510N LINE6. IF TREE6 CONFLICT WITH POWER LINES OR 6IGN6, CALL LANDSCAPE ARCHITECT TO RE60LVE BEFORE PLANTING. 13. CONTRACTOR 15 RESPONSIBLE FOR HAVING ALL UNDERGROUND UTILITIES LOCATED AND CLEARLY PAINTED WITHIN 10 DAYS OF ANY GROUND D15TUR13ING ACTIVITY. OWNER WILL NOT PAY FOR UTILITY REPAIRS DUE TO FAILURE TO MARK AND OBSERVE UTILITY LOCATIONS, 14. ADJUST TREE PLANTING LOCATIONS TO AVOID UNDERGROUND UTILITIES- PLANT 15FROM ALL UNDERGROUND UTILITIES (SEWER AND STORM DRAINAGE, GAS WATER, PHONE AND ELECTRICAL LINES). GENERAL 15. THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR THE QUANTITY OF PLANT5 SHOWN ON THE PLAN. ANY DISCREPANCIES BETWEEN QUANTITIES ON PLAN AND PLANT LIST SHALL BE BROUGHT TO THE ATTENTION OF THE LANDSCAPE ARCHITECT AND ANY FIELD ADJUSTMENTS OR QUANTITY ADJUSTMENTS MU6T BE AUTHORIZED PRIOR TO PLANTING. 16. ALL PLANTS SHALL BE GUARANTEED TO BE IN HEALTHY CONDITION FOR ONE (1) YEAR AFTER ACCEPTANCE BY OWNER OF ALL PLANT MATERIAL. 17, ALL DISTURBED ARFA6 SHALL BE SEEDED A6 SPECIFIED. 18. SEE EROSION CONTROL/GRADING PLAN FOR ADDITIONAL TREE PRESERVATION NOTES. IRRIGATION 19. THE LANDSCAPE CONTRACTOR SHALL PROVIDE A "DESIGN -BUILD° DRIP IRRIGATION SYSTEM FOR THE TREES, SHRUBS AND PERENNIALS IN AREAS INDICATED. SUBMIT PLAN TO LANDSCAPE ARCHITECT FOR REVIEW AND APPROVAL. LANDSCAPE CONTRACTOR TO COORDINATE PRE -PLANTING INSPECTION WITH CITY ARBORIST. LEGEND -°- environments life architecture planning Interiors 2815 coliseum centre drive, suite 500 charlotte, north caroling 28217 t] 704 379 1919 f] 704 379 1920 www.adwarchitects.com PLANT SCHEDULE TREES QTY BOTANICAL NAME / COMMON NAME ROOT CAL. REMARKS SIZE CK 3 Cornus kousa / Kousa Dogwood B & B 2"Cal MATCHED, STRAIGHT 6-8' HT. IN 20 Ilex x 'Nellie R Stevens' / Nellie Stevens Holly 30 gal PROPOSED CURB AND GUTTER FULL 6-8' HT. PC 6 Pistacia chinensis / Chinese Pistache B & B 2"Cal MATCHED, STRAIGHT 10-12' HT. PY 2 Prunus x yedoensis / Yoshino Cherry B & B 1.5 Cal MATCHED, STRAIGHT 8-10' HT. QS 16 Quercus shumardii / Shumard Red Oak B & B 2"Cal FULL 12'-14' ht, 6'4 UP 5 Ulmus parvifolia 'Bosque' / Bosque Elm B & B 2"Cal 10-12' HT. , DIFIC GENERAL' CONTRACTORS mop SmAq SHRUBS QTY BOTANICAL NAME / COMMON NAME CONT REMARKS HEIGHT SPREAD AX 34 Abelia x grandiflora 'Kaleidoscope' /Glossy Abelia 3 gal 3' O.C. 18-24" HT. 18-24" IC2 37 Ilex cornuta ' Burfordii Nana' / Dwarf Burford Holly 7 gal 4.5' O.C. 18-24" HT. 18-24" LC2 19 Loropetalum chinense 'Daruma' / Daruma Dwarf Loropetalum 3 gal 3' O.C. 15-18" HT. 15-18" LC3 58 Loropetalum chinense 'Ruby' / Ruby Loropetalum 5 gal 4' O.C. 18-24" HT. 18-24" MG2 18 Miscanthus sinensis ' Gracillimus' / Maiden Grass 3 gal 3.5' O.C. 18-24" HT. 18-24" PL 38 Prunus Iaurocerasus 'Otto Luyken' / Luykens Laurel 5 gal 4' O.C. 18-24" HT. 18-24" GROUND COVERS QTY BOTANICAL NAME / COMMON NAME CONT REMARKS SPACING LE 25 Helleborus x 'Golden Sunrise' / Lenton Rose I gal 24 O.C. LS 64 Liriope spicata 'Big Blue' / Creeping Lily Turf 4"pot 18" O.C. NT 60 Nassella tenuissima 'Pony Tails' / Mexican Feathergrass I gal 18" O.C. RF134 Rudbeckia fulgida sullivantii ' Goldsturm' / Black-eyed Susan I gal 18" O.C. VM 192 Vinca minor/ Common Periwinkle 4"pot 16" O.C. LANDSCAPE NOTES 1 MULCHLINE 3 (TYP,) 0 8 TREE PLANTING 5EED AREA � BERM (TOPSOIL/ QS C503 QS � I UNSUITABLE SOIL) 50' O.C. I c9 Vj � bEKM (TOPSOIL/ IN UNSUITABLE SOIL) °Tc_ 1 IN 3ERM (T0P5UIL_/ IN IN IN 5EED AREA — — — 5 — — IN — — �NLTA�1-E X011-) — 3 — — — — — — 3 — 25' FRONT SETBACK — — — — 3 — — — — - 3 NT c' -I 18 --945-��e * 5EED AREA 60 E�—E E E E . E E E- - ti u T PROPOSED R W /u off/u OH/ off/u off/u off off/u H/ o i/u off i, off/u uti a —off/u o+/u off/u, off/u�off/u o /u off/u- N e� 5EED AREA 945 FES 37 - o a EX. SOP I- T T T T i - T T T T T T T o � EXIST. PROPERTY LINE GEED SITE ALONG ROAD FRONTAGE TO WITHIN 6' OF EOP OR DENUDED LIMITS,' CP /N PAVEMENT EX. EOP WHICHEVER 15 GREATER (TYP.) BRISTOL DRIVE -SR 1358 WO IWOI WO W a (NO RECORDED R/W FOUND) I I I (ZONED: R-20) RESIDENTIAL (ZONED: R-20) RESIDENTIAL PLANT MATERIAL 1. MINIMUM TREE 51ZE AT PLANTING 16 2" CALIPER AND 6' TALL FOR 51NGLE-STEM TREES. ALL MULTI -STEM PLANTS MUST BE TREE FORM, MAXIMUM 3 TO 5 TRUNKS, AND MINIMUM 10' TALL. 2. ALL NEW TREES MUST HAVE STRAIGHT TRUNKS WITH STRONG CENTRAL LEADERS INTACT TO THE TOP OF THE CROWN UNLESS MULTI -STEM TREES ARE SPECIFIED. ALL TREES SHALL BE TYPICAL OF THEIR SPECIES AND VARIETY, HAVE NORMAL GROWTH HABITS, HAVE WELL- DEVELOPED BRANCHES, BE VIGOROUS AND HAVE FIBROUS ROOT SYSTEMS, TREES WITH CO -DOMINANT BRANCHING WILL NOT BE ACCEPTED. TREES THAT HAVE BEEN SHEARED, TOPPED OR CUT BACK TO MULTIPLY THE BRANCHING STRUCTURE WILL NOT BE ACCEPTED. TREES SHALL BE FREE OF ABRASIONS, DAMAGE, DISEASE, PESTS AND CRACKS. ALL PRUNING CUTS GREATER THAN I° DIAMETER SHALL HAVE CALLUS TISSUE FORMED PRIOR TO PLANTING. NO PRUNING CUT ON THE TRUNK SHALL BE MORE THAN ONE-HALF THE DIAMETER OF THE CENTRAL LEADER AT THE HEIGHT WHERE THE CUT WA6 MADE. ROOT FLARES SHALL BE LOCATED AT GRADE. TREES WITH MORE THAN 2" OF SOIL COVERING THE ROOT BALL/FLARE FROM WILL NOT BE ACCEPTED. 3. SIZE OF PLANTS, SPREAD OF ROOTS AND 61ZE OF BALLS SHALL BE IN ACCORDANCE WITH AN61 Z60.1 (LATEST EDITION) AS PUBLISHED BY THE AMERICAN NURSERY b LANDSCAPE A550CIATION. 4. ALL TREES OF A PARTICULAR SPECIES AND VARIETY SHALL BE UNIFORM IN 61ZE AND CONFIGURATION. PLANTING REQUIREMENTS 5. PLASTIC H06E PARTS WILL NOT BE ACCEPTED FOR TREE STAKING. SEE DETAILS AND SPECIFICATIONS FOR APPROVED STAKING METHOD/MATERIALS. 6. ALL STRAPPING, AND TOP I OF WIRE BASKET AND BURLAP MUST BE CUT AWAY AND REMOVED FROM ROOT BALL WHEN PLANTING. 7. FOR NEW PLANTING AREAS, REMOVE ALL PAVEMENT, GRAVEL SUB -BASE AND CONSTRUCTION DEBRIS; REMOVE COMPACTED 501L AND ADD 24" NEW TOP501L, OR TILL AND AMEND THE TOP 24" OF EX15TING 501L TO MEET TOPSOIL/ PLANTING MIX 6TANDARD5 FOR TREES. 8. ALL SAUCERS SHALL BE SOAKED WITH WATER AND MULCHED IMMEDIATELY FOLLOWING PLANTING. 9. THE TOP OF ALL ROOT BALLS FOR SHRUBS 6 GROUNDCOVERS SHALL BEAR THE SAME RELATIONSHIP TO FINISHED GRADE, A5 BORN TO PREVIOUS GROWING CONDITIONS. 10. ALL ROOT BALLS REMOVED FROM CONTAINERS SHALL BE SCARIFIED PRIOR TO BACKFILLING. 11. MULCH A MINIMUM 4 FOOT AREA AROUND EACH TREE AND - MULCH A CONTINUOUS AREA AROUND ALL SHRUB BEDS, A6 INDICATED ON THE PLAN. MULCH SHALL BE 3-4" THICK. MULCH AROUND TREES SHALL BE TAPERED TOWARD TRUNK 50 THAT NO MORE THAN 2" 15 PLACED AT TREE TRUNK A5 SHOWN ON DETAIL. SEE SPECIFICATIONS FOR TYPE. UTILITY ISSUES 12. LARGE MATURING TREES MAY NOT BE PLANTED WITHIN 25' OF OVERHEAD POWER DISTRIBUTION OR TRAN6MI6510N LINE6. IF TREE6 CONFLICT WITH POWER LINES OR 6IGN6, CALL LANDSCAPE ARCHITECT TO RE60LVE BEFORE PLANTING. 13. CONTRACTOR 15 RESPONSIBLE FOR HAVING ALL UNDERGROUND UTILITIES LOCATED AND CLEARLY PAINTED WITHIN 10 DAYS OF ANY GROUND D15TUR13ING ACTIVITY. OWNER WILL NOT PAY FOR UTILITY REPAIRS DUE TO FAILURE TO MARK AND OBSERVE UTILITY LOCATIONS, 14. ADJUST TREE PLANTING LOCATIONS TO AVOID UNDERGROUND UTILITIES- PLANT 15FROM ALL UNDERGROUND UTILITIES (SEWER AND STORM DRAINAGE, GAS WATER, PHONE AND ELECTRICAL LINES). GENERAL 15. THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR THE QUANTITY OF PLANT5 SHOWN ON THE PLAN. ANY DISCREPANCIES BETWEEN QUANTITIES ON PLAN AND PLANT LIST SHALL BE BROUGHT TO THE ATTENTION OF THE LANDSCAPE ARCHITECT AND ANY FIELD ADJUSTMENTS OR QUANTITY ADJUSTMENTS MU6T BE AUTHORIZED PRIOR TO PLANTING. 16. ALL PLANTS SHALL BE GUARANTEED TO BE IN HEALTHY CONDITION FOR ONE (1) YEAR AFTER ACCEPTANCE BY OWNER OF ALL PLANT MATERIAL. 17, ALL DISTURBED ARFA6 SHALL BE SEEDED A6 SPECIFIED. 18. SEE EROSION CONTROL/GRADING PLAN FOR ADDITIONAL TREE PRESERVATION NOTES. IRRIGATION 19. THE LANDSCAPE CONTRACTOR SHALL PROVIDE A "DESIGN -BUILD° DRIP IRRIGATION SYSTEM FOR THE TREES, SHRUBS AND PERENNIALS IN AREAS INDICATED. SUBMIT PLAN TO LANDSCAPE ARCHITECT FOR REVIEW AND APPROVAL. LANDSCAPE CONTRACTOR TO COORDINATE PRE -PLANTING INSPECTION WITH CITY ARBORIST. LEGEND -°- SIGN EXISTING LIGHT POLE EXISTING UTILITY POLE HC ACCESSIBLE SPACE EXISTING FIRE HYDRANT EXISTING TREE TO REMAIN PROPOSED GROUNDCOVER PLANT LABEL 12 PLANT QUANTITY - - - - - - EXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER --� PROPERTY LINE —x—x—x— EXISTING FENCE • •— PROPOSED FENCE UGE EXISTING UNDERGROUND ELECTRIC LINE —OH/U— EXISTING OVERHEAD UTILITY LINE EXISTING TREE LINE PROPOSED TREE LINE AFTER CLEARING - • - -' - PROPOSED MULCH LINE m- PROPOSED STORM DRAINAGE PIPE FD- PROPOSED FOUNDATION DRAIN SS SANITARY SEWER LINE DW WATER LINE Know what's below. Call before you dig. NORTH 30 0 15 30 60 SCALE; 1 =30' CONTACT: DAVID SALEEBY 349 NORTH CENTER ST. STATESVILLE NC 28677 704-878-3035 benesch Alfred Benesch & Company 2320 West Morehead Street Charlotte, INC 28208 www.benesch.com - 704.521.9880 Corp. NC License: F-1320 Project #17.000142 New Facility For IREDELL COUNTY PUBLIC SAFETY CENTER 404 Bristol Drive Statesville, NC SITE PLAN REVIEW CONSTRUCTION DOCUMENTS LANDSCAPE PLAN ENLARGEMENT DATE 5.22.2017 PROJECT NO 16029 REVISIONS NO DATE DESCRIPTION: THIS DRAWING IS THE PROPERTY OF ADW ARCHITECTS, PA. AND SHALL NOT BE REPRODUCED OR COPIED IN WHOLE OR IN PART. IT SHALL NOT BE USED ON ANY OTHER PROJECT OR GIVEN TO ANY OTHER COMPANY OR AGENCY WITHOUT THE CONSENT OF ADW ARCHITECTS, PA. Q��Qe��e.�ge9�9&9F:99®Oy�A e P,. ° o , 1647i 1141 SEAL �``®• ; ��'. B� SHEET NUMBER