Loading...
HomeMy WebLinkAboutSW3170802_Geotech Report/Property Deed_20170802e \ / 7606 Whitehall executive Center Drive, Suite 800 P17(V�ATC vt Charlotte, -5 28273 Tel. 704-529-3200 ATC ASSOCIATES OF NORTH CAROLINA, P.0 AUG 0 2 2017 Fax: 704-529-3272 Engineering Individual Solutions www atcassociates com IIFAIR-I AKin nl IAI ITY N.C. Engineering License No C-1598 STORMWATER PERMITTING July 12, 2017 Mr. Bart Hopper Hopper Communities 229 E. Jackson Avenue Charlotte, NC 28203 Subject: Geotechnical Engineering Evaluation Proposed Single Family Residential Community Weddington-Matthews Road Weddington, North Carolina ATC Project Number 199HOP1710 Dear Mr. Hopper: ATC Associates has completed the authorized Geotechnical Engineering Evaluation for the above referenced site. This report reviews our current understanding of the project, presents our exploration procedures, describes encountered subsurface conditions, and presents our evaluations, conclusions, and recommendations concerning geotechnical aspects of the project. PURPOSE AND SCOPE OF EXPLORATION The purpose of this work is (a) to further define and evaluate the subgrade soils with specific intent to these conditions as they relate to the site design and construction and (b) to provide recommendations as required for design and construction of the proposed building foundations, roadways, and utility infrastructure. Prior to the field exploration, a geotechnical engineer from our office evaluated the referenced information. The observations and findings were used in planning this exploration, in establishing areas of special Interest, and in relating site conditions to known geologic conditions in the area. SITE DESCIRPTION The property consists of two parcels, totaling 49.629 acres, located on the west side of Weddington — Matthews Road in Weddington, North Carolina. The property address is Weddington — Matthews Road in Weddington, Union County, North Carolina. The surrounding area is mostly residential and undeveloped. The vicinity of the subject property is characterized by residential use to the north, east, and south, and undeveloped land to the west. Local topography slopes from the center of the property out towards the property boundaries. The property is currently developed with seven mobile home structures, one residence on Blrchaven Drive and one residence on Hemby Road. There is a garage and two sheds associated with the Hemby Road residence. A majority of the property is undeveloped wooded land. Weddington-Matthews Road Weddington, North Carolina FIELD EXPLORATION In order to evaluate subsurface conditions of the proposed residential community and per your authorization, a subcontractor working under the direction of ATC performed ten soil test borings (designated B-01 through B- 10) at the approximate locations indicated on the attached Boring Location Plan. The GPS coordinates of each of the boring locations is indicated on the attached Boring Location Plan. Seven of the soil test borings were drilled using a truck -mounted rig with a manual Standard Penetration Test (SPT) hammer. These borings were extended to depths of 20 feet below the existing ground surface elevation. Three of the borings were performed using Hand Auger drilling techniques due to the heavy vegetation on the site. Soil samples were collected during the drilling operations and retained in the field by ATC personnel. The samples were brought back to the laboratory where each was classified by the geotechnical engineer using the Unified Soil Classification System. These classifications were based on visual examination and selected laboratory testing. The soil descriptions on the attached Soil Boring Logs should be considered approximate. The soil drilling logs are included in the report Appendix. The groundwater observations represent conditions at the time of drilling. SUBSURFACE CONDITIONS The subsurface conditions discussed in the following paragraphs and those shown on the logs represent an estimate of the subsurface conditions based on interpretation of the field data using normally accepted geotechnical engineering judgments. We note that the transition between different soil strata is generally less distinct than those indicated on the logs. Although individual logs are representative of the subsurface conditions at the locations shown, they are not necessarily indicative of subsurface conditions at other locations or at other times. Residual Soils Residual soils were encountered in the soil test borings and underlying the referenced fill materials. The residual soils generally consisted of sandy and elastic SILT (ML) and (MH) and silty sand (SM) materials. The following laboratory tests were performed on the bag soil samples obtained at the site. The laboratory test results will be provide on completion. Groundwater Groundwater conditions were encountered during the drilling operations at depths ranging 1.5 to 17 feet below the existing ground surface. We expect that the groundwater encountered at 1.5 feet was a perched water condition. It should be noted that groundwater levels can fluctuate significantly with seasonal and climatic variations and may be different at other times. MATC ucas ftrts ar xortrr, csawnraec Cn9fnocdnry NrOlvlOw I Solutlons Weddington-Matthews Road Weddington, North Carolina CONCLUSIONS AND RECOMMENDATIONS General Findings and Recommendations The following geotechnical conclusions and recommendations are based on our observations at the site, interpretation of the field data obtained during the explorations, and our experience with similar subsurface conditions. SPT N -Values have been used to estimate allowable bearing pressures using industry recognized correlations. Subsurface conditions in unexplored locations may vary somewhat from those encountered. Based on the results of the soil test borings performed, the site contains some near surface low and high plasticity silts (ML and MH). With depth, the silty soils transition to silty sand soils and partially weathered rock materials. The high plasticity elastic SILTS were encountered within generally the uppermost 3.5 to 6 feet of the existing ground surface in some portions of the site. However, deeper depths are encountered in some areas of the site. The moisture content tests indicated that some of these materials are at moisture contents near or above their optimum moisture contents. The high plasticity silts encountered at the site are moisture sensitive and may become unstable when exposed to moisture and heavy construction traffic. If unstable soil conditions are encountered during the site construction operations, selected undercutting will be required as determined by qualified site personnel. It is recommended that the proposed building pad slob not bear directly on MH soils. We recommend at least 2 feet of engineered fill per placed between the floor slabs and any high plasticity elastic silts (MH). The ML, CL, and SM soils are suitable for use as fill materials and foundation bearing materials if the materials are at or below their optimum moisture content and undergo a successful proofroll. Mass undercutting of the materials is not recommended or expected. Some undercutting operations of the near surface soils may be required as site conditions at the time of construction dictate, but extensive undercutting of the materials is not anticipated. Additional recommendations regarding the soil use are provided in Site and Subgrade Preparation section of this report. Preliminary Foundations Recommendations Pending completion of site and subgrade preparation as discussed in this report, the proposed single family structures can be supported on shallow spread and continuous wall foundations orturned-down monolithic slabs bearing on the in-place residual soils or properly placed structural fill placed over stable soils. A net allowable design foundation bearing pressure of 2,000 pounds per square foot (psf) can be used for foundation design. Total preliminary settlements are expected to be 1 -inch or less with differential settlements between adjacent column footings of %-inch or less with a design foundation bearing pressure of 2,000 psf. These settlement estimates are dependent on proper implementation of the recommended site preparation measures. We recommend widths of not less than 24 inches for rectangular and continuous footings for ease of construction and to reduce the possibility of localized shear failures. Exterior footing bottoms should be at least 24 inches below exterior grades for protection against frost damage and erosion. (VkTc ATGI550GU1C5 GP dl Engtn¢nrtnq!tltvidunlSolutions Weddington-Matthews Road Weddington, North Carolina Construction and Evaluation Bottoms of foundation excavations should be evaluated by a geotechnical engineer prior to placement of reinforcing steel and concrete to verify that adequate bearing materials are present and that all debris, mud, and loose, frozen or water -softened soils are removed. Foundation excavations should be concreted as soon as practical after they are excavated. Water should not be allowed to pond in any excavation. If an excavation is left open for an extended period, a thin mat of lean concrete should be placed over the bottom to minimize damage to the bearing surface from weather or construction activities. Foundation concrete should not be placed on frozen or saturated subgrades. Groundwater Conditions If groundwater is encountered, the contractor should be responsible for assuring adequate groundwater control is in-place and functioning prior to the start of any work to allow the work to be performed in a dry (free from flowing or standing water) condition. The contractor should be responsible for establishing the means and methods of groundwater control and to include all such items in his bid and scope of work. Methods to control groundwater include temporary ditches, sumps, pumps, well points, or other methods. In order to prevent adverse effects of groundwater to exposed subgrade materials, it has been our experience that groundwater levels when lowered and maintained at a depth of at least 3 feet below the limits of subgrade excavation and undercutting elevation typically provide a stable working platform. Additionally, the dewatering system should be in-place and functioning sufficiently prior to beginning earthwork construction within the area. Inadequate dewatering may cause the subgrade to destabilize under loads from earthwork equipment and be problematic in placement and compaction of fill soils. Site and Subgrade Preparation All vegetation, root systems, and other deleterious non -soil materials and topsoil should be stripped from proposed construction areas. Topsoil may be stockpiled and reused later in landscaped areas or other non -load bearing areas. After clearing, stripping, and undercutting, areas intended to support floor slabs, pavements, new fill, and foundations should be carefully evaluated by a geotechnical engineer. At that time, the engineer may require proofrolling of the subgrade with a 20- to 30 -ton, loaded dump truck or other pneumatic -tired vehicle of similar size and weight. The purpose of the proofrolling is to locate soft, weak, or excessively wet soils present at the time of construction that may not have been detected in our borings. Any unsuitable materials observed during the evaluation and proofrolling operations should be undercut and replaced with compacted fill or stabilized in-place. Low to high plasticity silts were encountered in the some of the near surface soils at the site. Based on the in- place moisture contents of these soils, utilization of these soils as structural fill material may be difficult in seasonally wet periods of the calendar year. In some instances mechanical or chemical drying of the soils prior to placement and compaction may be required. The silty and potential clayey soils encountered on-site are moisture sensitive and if these soils are subjected to moisture and construction traffic they may become unstable and require stabilization or removal and replacement. At the time of construction and prior to fill placement operations, an ATC Geotechnical Engineer should evaluate these areas. (MATC VASSOM.gl0f11ld CAW.11Fs EnDlnccrfnq hrtllvltlua! Solutlnns Weddington-Matthews Road Weddington, North Carolina Soil Supported Slabs Floor slabs for the proposed building may be soil -supported and subject to the subgrade preparation and earthwork recommendations contained in this report. Provided the subgrade is prepared as recommended and a 6 -inch thick layer of gravel (ASTM #57 stone or GAB) is properly placed and compacted, a subgrade modulus (k) of 125 pci may be used for the design of the floor slab based on short term and concentrated loads, such as fork lift loads. This value is based on soil properties evaluated from field and laboratory data. The value is appropriate for design using the Portland Cement Association (PCA) publication "Slab Thickness Design for Industrial Concrete Floors or Grade." If alternate design methods are used for slab design, ATC should be consulted such that appropriate parameters can be provided. Structural Fill Natural moisture content analysis was performed to assess the suitability of the on-site soils in cut areas for re- use as structural fill. Our testing and observation of the soil samples indicates that the in-situ moisture content of the on-site soils is generally at or above the soils optimum moisture content range required for compaction. These soils included silty sands, sandy clays sandy elastic silts, and sandy silts. Soil should generally be within + 3 percent of optimum moisture content for use as structural fill. The wetter than optimum soils encountered above groundwater levels will require drying for re -use as structural fill. Mechanical drying (discing) is one option for drying the wetter than optimum soils. Mechanical drying is time- consuming and is dependent on ideal weather. Chemical drying with lime or soil cement is a less time consuming option, as is mixing the wetter soils with drier soils. Chemical drying or mixing should be performed under the supervision of the Geotechnical Engineer. Structural fill installed to replace undercut areas or achieve finished grades should be free of deleterious materials and rock fragments larger than 3 inches in diameter and placed at soil moisture contents within 3 percent of the soil's optimum moisture content. Import fill materials should be evaluated prior to use for adherence to CBR and unit weight requirements. The following guidelines are recommended and preferred: Maximum Dry Density (ASTM D-698 Method) >_90 pcf Liquid Limit <_50 Plasticity Index <_25 California Bearing Ratio >_5 Structural fill should be placed in lifts of 6 to 8 inches loose measure. We recommend that structural fill within the building pad or parking areas be compacted to a minimum of 95 percent of the Standard Proctor maximum dry density. Structural fill in the upper 1 foot below floor slab and pavement subgrade should be compacted to at least 98 percent of Standard Proctor. All fill material should be placed in horizontal lifts and adequately keyed into stripped and scarified subgrade soils. V ATIC 4TCIS^aoCL,VlOPN d CUioml Ps Engtatv;rinq brdlufdwr! Solatlaay Weddington-Matthews Road Weddington, North Carolina Slopes, embankments, and inclines on greater than 5 horizontal to 1 vertical may require benching in order to place and compact fill to the required density and to establish an adequate bond between lifts. Prior to fill placement, approved surfaces should be scarified or rolled with a sheepsfoot type roller. During fill placement, density tests should be performed by a soils technician to determine the degree of compaction and compliance with the project specifications. For underfloor areas, at least one field density test should be made per 2,500 square feet of fill area for each 1 -foot thickness of compacted soil. Testing frequency should be increased in confined areas. Any areas that do not meet the compaction specifications should be recompacted to achieve compliance. We recommend that the grading contractor have equipment on site during earthwork for both drying and wetting fill soils. We do not anticipate significant problems in controlling moistures within the fill during dry weather, but moisture control may be difficult during winter months or extended periods of rain, especially if poor grading practices are used. Wet Weather Construction Site grading that occurs during traditional wet weather periods will be problematic at this site. Some targeted undercutting of saturated soils and chemical drying may be required if prolonged periods of unfavorable weather conditions occur during fill placement operations at the site. Although specific recommendations would be made at the time of construction, the following guidelines are provided. • Saturated surface soils are difficult to dry by mechanical and/or chemical methods depending on the season and the soil type. Consequently, consideration should be given to removal and wasting of saturated surface soils at the site. • Lime or cement can be an effective in drying of soils that are typically about 4 to 8 percent wet of their optimum moisture content. We expect chemical drying will be required during periods of wet weather construction. • The on-site soils are sensitive to excessive moisture. These soils types may require undercutting and chemical drying if subjected to inclement weather conditions. • Disturbed or uncompacted soils will more readily absorb and hold water. Disturbed or uncompacted soils should be kept to a minimum area. Special attention and detail should be given to "sealing -off" or compaction with a sooth drummed roller of disturbed areas prior to wet weather periods. The contractor should also provide cut ditches to channel surface water runoff from the construction areas. The site should also be graded to prevent ponding of water on the site. Pumping should be performed in a timely manner in areas where water has collected. (YVATC s m xoam cuxaavr.rr En91nccring Indlvldunf Sola(Ians Weddington-Matthews Road Weddington, North Carolina Retaining Walls Earth pressures on walls below grade are influenced by structural design of the walls, conditions of wall restraint, methods of construction and/or compaction, and the strength of the materials being restrained. The most common conditions assumed for earth retaining wall design are the active and at -rest conditions. Active conditions apply to relatively flexible earth retention structures, such as freestanding walls, where some movement and rotation may occur to mobilize soil shear strength. Walls which are rigidly restrained, such as basement, tunnel, or loading dock walls, should be designed for the at -rest condition. A third condition, the passive state, represents the maximum possible pressure when a structure is pushed against the soil, and is used in wall foundation design to help resist active or at -rest pressures. Because significant wall movements are required to develop the passive pressure, the total calculated passive pressure should be reduced by one-half for design purposes. Based on previous experience with similar soils and construction, we recommend the following earth pressure coefficients and equivalent fluid pressures for design of reinforced concrete retaining or below grade walls on this project: Earth Pressure Conditions Coefficient Recommended Equivalent Fluid Pressure, (pcf) Active (Ka) 0.36 43 At -Rest (Ko) 0.53 64 Passive (KP) 2.77 166 A moist soil unit weight of 120 pounds per cubic foot (pcf) should be used for design calculations. Our recommendations assume that the ground surface above the wall is level. A coefficient of friction value between soil and concrete of 0.35 is recommended. A preliminary allowable bearing pressure of 2,000 psf may be used for footings designed to bear on competent existing fill materials, residual soils, or new structural fills. The recommended equivalent fluid pressures assume that constantly functioning drainage systems are installed between walls and soil backfill to prevent the accidental buildup of hydrostatic pressures and lateral stresses in excess of those stated. If a functioning drainage system is not installed, then lateral earth pressures should be determined using the buoyant weight of the soil (approximately 58 pcf). Hydrostatic pressures calculated with the unit weight of water (62.4 pcf) should be added to these earth pressures to obtain the total stresses for design. Tractors and other heavy equipment should not operate within 10 feet of below grade walls to prevent lateral pressures in excess of those cited. If foundations or other surcharge loadings are located a short distance outside below grade walls, they may also exert appreciable additional lateral pressures that must be considered in design. These retaining wall/below grade wall recommendations should not be correlated with soil parameters for use in mechanically stabilized earth (MSE) wall design. We recommend that soil parameters for any MSE retaining wall design be established through appropriate laboratory testing by the wall designer. 7( V0 %T C ATEFS� d. ffS WNId GM. Mlon, Gr�lrrcrr/nq lirtl/vldu.e/ Salaflons Weddington-Matthews Road Weddington, North Carolina Recommended Pavement Desien and Construction Based on the anticipated site loading and volumes and an estimated California Bearing Ratio (CBR) value of 4 to 6 based on the on-site soil conditions, we recommend the below pavement sections for the site. Light Duty Asphalt Pavement: 2 inches of asphaltic concrete (2.0 -inches of Surface Course SM -9.5) overlying a minimum of 8 -inches of compacted Aggregate Base Course (ABC). Heavy Duty Asphalt Pavement: 3 inches of asphaltic concrete (1.25 -inches of Surface Course SM -9.5 and 1.75 -inches of Intermediate Course IM -19.0) overlying a minimum of 8 -inches of compacted Aggregate Base Course (ABC) The recommended pavement design alternatives are subject to successful completion of site and subgrade preparation and structural fill placement as recommended in this report. If off-site soils are used in paved areas, this pavement design may require revision. The compaction, quality, and gradation of the aggregate base course materials will directly affect the quality and life of the pavement section. Consequently, we recommend a minimum compaction of 100 percent of the Modified Proctor maximum dry density for the aggregate base course material (ABC) as determined by the North Carolina Department of Transportation. A soil engineering technician working under the direction of a geotechnical engineer should observe placement and compaction of the base course material and perform soil density tests to confirm that the material has been placed in accordance with our recommendations. Seasonal Groundwater Conditions Based on the data collected, we estimate that the Seasonal High Groundwater Table at the site per the Table provided below. Boring No. Estimated Seasonal High Groundwater Elevation, ft. J I B-01 690 B-02 690 B-03 690 (:V%ATC trocng oe fSouwac Fnglnccring prdlWduWdu.d Solullons Weddington-Matthews Road Weddington, North Carolina CLOSURE ATC appreciates the opportunity to be of continued service to you on this project. Please contact us if you have any questions about this report, or if we may be of further service. Sincerely yours, ATC Associates of N.C., P.C. Brain Carpenter, P.E. Staff Engineer CVYATCnq,-d_Q IORHid IS.1.11 - EngJriccrinq !/tdlHduJ/ SolcflOrts Joseph G. Schold, P.E. Principal Geotechnical Engineer Registered, N.C. 21736 n Vp 1'0 ?35�' 2'6;98' N�;SW4'50, 20".W.. ' 'A. #P Rq .' �'• ° 2'4 70''`N, 80�44'37�67"W� ` cg 6bN 6b B 9, 35 273.2.2N,;80°44'4;7.65" O •fl' - xi -8, 350,2'0 -86"N 8 44 49 36"UV B 5 35° 21;,,37 N;�8,0°4;47-11 321N w t ` j�8 5 1 58 0 �'1' Y .. -4, 3 '' , 82 N�, 8 44 4 �'3'a`•' �a r '-6-2 ,35 1'58 4f 'N, 80.44'52.36' W% B-3,:-3,6' 1;58;28"N„ 80'.4°4'5W7 ,"IN" 41 y f 56 '� , 46N,84445.50"W 4 K t a "DiolA to *1A y .w N 7606 Whitehall Executive Center Drive TEST BORING LOG Ar AkTCCharlotte, NC 28273 jr 704-529-3200 Fax 704-529-3272 CLIENT ATC Group Services, LLC BORING # B-01 PROJECT NAME Weddington-Matthews, Geotechnical Phase JOB # 199HOP1710 PROJECT LOCATION Hemby Road DRAWN BY JL Weddington, North Carolina APPROVED BY JIGS DRILLING and SAMPLING INFORMATION TEST DATA Date Started 7/6/17 Hammer Wt. NA lbs Date Completed 7/6/17 Hammer Drop NA in. Drill Foreman JL/ES Spoon Sampler OD NA in Inspector MB Rock Core Dia NA in Boring Method HAND AUGER Shelby Tube OD NA in �L o w o a 2 J E Ca� nm T C) c3 'a) _0 - cn `co c w U v a E o v SOIL CLASSIFICATION aci t t o o n o 2 a oZ -o y n SURFACE ELEVATION `� ani m y m o m m a"i ° aNi a o o a :j n o CD 12� cn ❑ o cn cn z U X U) H 00 2 a a 6" TOPSOIL 05 1.5 3RAE5 17.5 DCP Blow Counts Brown sandy SILT with some clay 1 Tan and orangish brown sandy SILT with trace 11-20 organics 35 GRAE5 158 DCP Blow Counts 25-23 2 Brown and tan silty coarse SAND 5 60 :3RAE5 129 DCP Blow Counts 25+ 3 HAND AUGER TERMINATED Sample Type SS - Driven Split Spoon ST - Pressed Shelby Tube CA - Continuous Flight Auger RC - Rock Core CU - Cuttings CT - Continuous Tube Depth to Groundwater ! Noted on Drilling Tools NA ft I At Completion (in augers) NA ft. 9 At Completion (open hole) NA ft 7- After NA hours NA ft. t After NA hours NA ft. X Cave Depth NA ft. Boring Method HSA - Hollow Stem Augers CFA - Continuous Flight Augers DC - Driving Casing MD -Mud Drilling Page 1 of 1 IF 7606 Whitehall Executive Center Drive TEST BORINGLOG ACharlotte, NC 28273 NkTc704-529-3200 Date Completed 6/21/17 Hammer Drop NA in Fax 704-529-3272 CLIENT ATC Group Services, LLC BORING # B-02 PROJECT NAME Weddington-Matthews, Geotechnical Phase JOB # 199HOP1710 PROJECT LOCATION Hemby Road DRAWN BY JL Weddington, North Carolina APPROVED BY JGS DRILLING and SAMPLING INFORMATION TEST DATA Date Started 6/21/17 Hammer Wt. NA lbs Date Completed 6/21/17 Hammer Drop NA in Drill Foreman JL/MHO Spoon Sampler OD NA in Inspector MB Rock Core Dia NA in. rn U) Boring Method HAND AUGER Shelby Tube OD NA in. 0 ° % o a m 2 o a> E o n n EC7 L m $? 10 c 3 a 0 ca) o U> m c 0 v 0 t - o C SOIL CLASSIFICATION -o � J n n E r o o a a a> o: - z N n w � a) `a E SURFACE ELEVATION ° ani ani U m o m m ami 2 0 . n o o Er m U U) 0 o rn U) z cn U) of cn X 00 2E_j a o- 6" TOPSOIL 0.5 1.5 RA 152 DCP Blow Counts Brownish tan silty SAND with rock fragments 1 Brown, tan, and reddish brown sandy SILT with some 16-24 rock fragments 2 GRAE5 154 DCP Blow Counts 4.515-16 3 RA 2 8 DCP Blow Counts Reddish brown sandy SILT 5 10-12 6.5 RA 442 DCP Blow Counts 12-16 4 HAND AUGER REFUSAL Sample Type SS - Driven Split Spoon ST - Pressed Shelby Tube CA - Continuous Flight Auger RC - Rock Core CU - Cuttings CT - Continuous Tube Depth to Groundwater ! Noted on Drilling Tools NA ft. f At Completion (in augers) NA ft. 6 At Completion (open hole_) NA ft. 3 After NA hours NA ft. T After NA hours NA ft !a Cave Depth NA ft Boring Method HSA - Hollow Stem Augers CFA -Continuous Flight Augers DC - Driving Casing MD -Mud Drilling Page 1 of 1 AW7606 Whitehall Executive Center Drive TEST BORING LOG JVAkT Charlotte, NC 28273 ® 704-529-3200 Fax 704-529-3272 CLIENT ATC Group Services, LLC PROJECT NAME Weddington-Matthews, Geotechnical Phase PROJECT LOCATION Hemby Road Weddington, North Carolina DRILLING and SAMPLING INFORMATION BORING # B-03 JOB # 199HOP1710 DRAWN BY JL APPROVED BY JGS TEST DATA Date Started 6/21/17 Hammer Wt. NA lbs Date Completed 6/21/17 Hammer Drop NA in. Drill Foreman JL/MHO Spoon Sampler OD NA in. Inspector MB Rock Core Dia NA in rn Boring Method HAND AUGER Shelby Tube OD NA In. 47 U - L o - O o w 'O N 2 C a) E L D_ (� « a) N O O C win V> a) O J J d O` C SOIL CLASSIFICATION ~ 3 ao L E 7 L O a) a a> `m d a a) o >0 7 "O ? d O_ 'O V Y a7 SURFACE ELEVATION 16' a a) o m m U E as o E E as m 5 o a> 7 c w as a> E > o o Cr n M v O E 0 cn0 0U Uz U U)Q �H C7U n a 6" TOPSOIL f 05 1 5 3RAEG 159 DCP Blow Counts Brown sandy SILT with trace organics 1 Reddish brown sandy SILT 5-6 35 3RAE5 22 DCP Blow Counts 2 Tan and gray SILT with some sand 13-16 5.5 5 3RAE5 397 DCP Blow Counts 3 Reddish brown sandy clayey SILT 9-11 5 3RAE5 588 DCP Blow Counts 11-10 4 Orangish brown sandy clayey SILT 95 3RAE5 DCP Blow Counts 5 HAND AUGER TERMINATED 3-6 Sample Type SS - Driven Split Spoon ST - Pressed Shelby Tube CA - Continuous Flight Auger RC - Rock Core CU - Cuttings CT - Continuous Tube Depth to Groundwater .0 Noted on Drilling Tools NA ft f At Completion (in augers) NA ft At Completion (open hole) NA ft Y After NA hours NA ft. 1 After NA hours NA ft g Cave Depth NA ft. Boring Method HSA - Hollow Stem Augers CFA - Continuous Flight Augers DC - Driving Casing MD -Mud Drilling Page 1 of 1 AV 7606 Whitehall Executive Center Drive TEST BORING LOG ®CAkT Charlotte, NC 28273 704-529-3200 Fax 704-529-3272 CLIENT ATC Group Services, LLC BORING # B-04 PROJECT NAME Weddington-Matthews, Geotechnical Phase JOB # 199HOP1710 PROJECT LOCATION Hemby Road DRAWN BY A Weddington, North Carolina APPROVED BY JIGS nRn I INC; anri SAMPI INC; INFnRMATIC)N TFST nATA Date Started 6/28/17 Hammer Wt. 140 lbs. Date Completed 6/28/17 Hammer Drop 30 in. Drill Foreman RDL Spoon Sampler OD 2 in. Inspector MB Rock Core Dia NA In. C: L U) Boring Method HSA Shelby Tube OD NA in oz ° o m o m o ? am o E _E aJ n(L d N (� .0.• C N O O C I > a) O v a C SOIL CLASSIFICATION z Z � j n Y E Rr Z.2 o n o n a> -o y a SURFACE ELEVATION cu ani ani v m o m m aUi aNi C o o Q a m U) 0 0 (n al Z (n U) [Y F 00 : d a 2" TOPSOIL 02 Offset 30 feet SS 5 tree line due Firm to very stiff reddish brown sandy SILTfrom 1 to overly wet conditions SS 26 2 5 6.0 3 Very stiff brown and tan sandy SILT SS 21 SS 25 4 100 10 BORING TERMINATED Sample Type SS - Driven Split Spoon ST - Pressed Shelby Tube CA - Continuous Flight Auger RC - Rock Core CU - Cuttings CT - Continuous Tube Depth to Groundwater ! Noted on Drilling Tools 1.5 ft. f At Completion (in augers) 2.0 ft. At Completion (open hole) NA ft. s After NA hours NA ft. X After NA hours NA ft _V Cave Depth NA ft Boring Method HSA - Hollow Stem Augers CFA - Continuous Flight Augers DC - Driving Casing MD -Mud Drilling Page 1 of 1 N 7606 Whitehall Executive Center Drive TEST BODING LOGC/ / Charlotte, NC 28273 704-529-3200 Fax 704-529-3272 CLIENT ATC Group Services, LLC PROJECT NAME Weddington-Matthews, Geotechnical Phase PROJECT LOCATION Hemby Road Weddington, North Carolina npu I INC, nnri SAMPI INC, INIMRMATinN BORING # B-055 JOB # 199HOP1710 DRAWN BY JL APPROVED BY JGS TEST DATA Date Started 6/28/17 Hammer Wt. 140 lbs Date Completed 6/28/17 Hammer Drop 30 in. Drill Foreman RDL Spoon Sampler OD 2 in. Inspector MB Rock Core Dia NA in. w Boring Method HSA Shelby Tube OD NA in. w° �t16 o o m c 2 o y E n `��° cc0 C7 " 0 — rn 0 U > a) o J a o C SOIL CLASSIFICATION m z a Y E r r a a a o -o w cL a g a� m SURFACE ELEVATION m a) (n C) ° 0 U) m o � Z m m a U) rn of o f0 a Cn F o a U � Q J o d o d a' � 4" TOPSOIL 0.3 SS 18 Very stiff reddish brown and brown sandy elastic 1 SILT X 25 - Very stiff reddish brown sandy SILT SS 26 2 5 SS 20 3 SS 29 4 10 0 10 BORING TERMINATED Sample Twe SS - Driven Split Spoon ST - Pressed Shelby Tube CA - Continuous Flight Auger RC - Rock Core CU - Cuttings CT - Continuous Tube Depth to Groundwater -0 Noted on Drilling Tools Dry ft S At Completion (in augers) Dry ft. 6 At Completion (open hole) NA ft 7 After NA hours NA ft t After NA hours NA ft _ Cave Depth NA ft Boring Method HSA - Hollow Stem Augers CFA - Continuous Flight Augers DC - Driving Casing MD -Mud Drilling Page 1 of 1 ;STC 7606 Whitehall Executive Center Drive Charlotte, NC 28273 704-529-3200 Fax 704-529-3272 CLIENT ATC Group Services, LLC PROJECT NAME Weddington-Matthews, Geotechnical Phase PROJECT LOCATION Hemby Road Weddington, North Carolina nRII I INC; nnri RAMPI IN(', INFC)RMATIC)N BORING #_ JOB # DRAWN BY TEST BORING LOG B-06 199HOP1710 JL APPROVED BY JGS TFST nATA Date Started 6/28/17 Hammer Wt 140 lbs. Date Completed 6/28/17 Hammer Drop 30 in Drill Foreman RDL Spoon Sampler OD 2 In Inspector MB Rock Core Dia NA in Cn } Boring Method HSA Shelby Tube OD NA in U) m o a B nm a m� din C o wCn o> N o v J a C SOIL CLASSIFICATION z J J a Y E t .L... C L E E to d 5 SURFACE ELEVATION m Co m o ami ° 0 U7 o 0 U) ❑ 0 rn rn z rn Cn W F Ci U _j a a 6" TOPSOIL f 05 SS 17 Very stiff reddish brown sandy elastic SILT 1 25 Very stiff to stiff reddish brown and brown sandy SILT SS X 20 2 5- SS 21 3 SS 22 4 10 SS 10 5 150 15 BORING TERMINATED Sample Type SS - Driven Split Spoon ST - Pressed Shelby Tube CA - Continuous Flight Auger RC - Rock Core CU - Cuttings CT - Continuous Tube Depth to Groundwater * Noted on Drilling Tools D!y ft. f At Completion (in augers) Dry ft. § At Completion (open hole) NA ft. 7 After NA hours NA ft Y After NA hours NA ft. 1U Cave Depth NA ft Boring Method HSA - Hollow Stem Augers CFA - Continuous Flight Augers DC - Driving Casing MD -Mud Drilling Page 1 of 1 A 7606 Whitehall Executive Center Drive TEST BORING LOG VAkT Charlotte, NC 28273 ® 704-529-3200 Fax 704-529-3272 CLIENT ATC Group Services, LLC PROJECT NAME Weddington-Matthews, Geotechnical Phase PROJECT LOCATION Hemby Road Weddington, North Carolina rlpli I INV', a ,! CAIIAPI INV'. INFC1pKAATi()N BORING # B-07 JOB # 199HOP1710 DRAWN BY JL APPROVED BY JGS TEST DATA Date Started 6/28/17 Hammer Wt. 140 lbs. Date Completed 6/28/17 Hammer Drop 30 In Drill Foreman RDL Spoon Sampler OD 2 In in Inspector MB Rock Core Dia NA in. c w Boring Method HSA Shelby Tube OD NA in. c m o m c = c w? E r nm C7 1 m° am � c 3 - cn c c w Av U J a E o aci a SOIL CLASSIFICATION z)_ w m o n. E m: n cL E E°o _ Z � m cL of �, «� �' v_ o n a> cc E SURFACE ELEVATION mn m o� m o m o m m a> w � in a a o o cc a o m U) o ❑ cn cn z rn cn 0 1- v ; a ' 6" TOPSOIL f 0.5 SS 20 Very stiff reddish brown sandy elastic SILT 1 SS 13 2 5 SS 14 3 75 PARTIALLY WEATHERED ROCK Sampled as tan and gray silty sand 4 SS 50/6" 100 10 BORING TERMINATED Sample Type SS -Driven Split Spoon ST - Pressed Shelby Tube CA - Continuous Flight Auger RC - Rock Core CU - Cuttings CT - Continuous Tube Depth to Groundwater a Noted on Drilling Tools Dry ft. f At Completion (in augers) Dry ft. At Completion (open hole) NA ft Y After NA hours NA ft. t After NA hours NA ft. V Cave Depth NA ft Boring Method HSA - Hollow Stem Augers CFA - Continuous Flight Augers DC - Driving Casing MD -Mud Drilling Page 1 of 1 ®7606 Whitehall Executive Center Drive TEST BORING LOGAV k CCharlotte, NC 28273 704-529-3200 Fax 704-529-3272 CLIENT ATC Group Services, LLC PROJECT NAME Weddington-Matthews, Geotechnical Phase PROJECT LOCATION Hemby Road Weddington, North Carolina DRILLING and SAMPLING INFORMATION BORING # B-08 JOB # 199HOP1710 DRAWN BY JL APPROVED BY JGS TEST DATA Date Started 6/28/17 Hammer Wt 140 lbs Date Completed 6/28/17 Hammer Drop 30 in Drill Foreman RDL Spoon Sampler OD 2 in. Inspector MB Rock Core Dia NA in C Boring Bong Method HSA Shelby Tube OD NA in. �L '0 ° m _ a_ a� E n al as CD � i0 a) in C: 3 0 d - U) c U > a) O J d `O SOIL CLASSIFICATION a m J j EL Y E 7 L L O a1 n O_ > C .D z N n V a) ° a3 E SURFACE ELEVATION `� ani aai cf0i m o ccaa m aa) ° O m o o L7 m � ❑ D cn z cn cn H C7 U a a° 4" TOPSOIL 03 SS 18 Very stiff reddish b brown sandy elastic SILT 1 SS 21 2 50 5 Very stiff to stiff reddish brown and brown sandy SILT SS 22 3 SS 16 4 10 SS 9 5 15 SSX 9 6 20.0 20 BORING TERMINATED Sample Type SS - Driven Split Spoon ST - Pressed Shelby Tube CA - Continuous Flight Auger RC - Rock Core CU - Cuttings CT - Continuous Tube Depth to Groundwater A Noted on Drilling Tools 17.0 ft S At Completion (in augers) NA ft. 6 At Completion (open hole) NA ft -7 After NA hours NA ft t After NA hours NA ft _* Cave Depth NA ft. Boring Method HSA - Hollow Stem Augers CFA - Continuous Flight Augers DC - Driving Casing MD -Mud Drilling Page 1 of 1 . / 7606 Whitehall Executive Center Drive TEST BORING LOG /C Charlotte, NC 28273 / 704-529-3200 Fax 704-529-3272 CLIENT ATC Group Services, LLC 3 BORING # B-09 PROJECT NAME Weddington-Matthews, Geotechnical Phase JOB # 199HOP1710 PROJECT LOCATION Hemby Road DRAWN BY JL CL Weddington, North Carolina c, APPROVED BY JGS DRILLING and SAMPLING INFORMATION TEST DATA Date Started 6/28/17 Hammer Wt. 140 lbs. C7 Date Completed 6/28/17 Hammer Drop 30 in E E J aa) a Drill Foreman RDL Spoon Sampler OD 2 in J L L n a a 8 Inspector MB Rock Core Dia NA in. C: w a� o E m o E m Ev m a� Boring Method HSA Shelby Tube OD NA in U) �L °o o m -oma 2 � o cn J a� y E rn o SOIL CLASSIFICATION SURFACE ELEVATION 4" TOPSOIL Very stiff reddish brown sandy elastic SILT Medium dense reddish brown silty SAND Firm brown sandy SILT Loose brown and tan silty SAND BORING TERMINATED Sample Type SS - Driven Split Spoon ST - Pressed Shelby Tube CA - Continuous Flight Auger RC - Rock Core CU - Cuttings CT - Continuous Tube 03 1 SS 18 2.5 2 SS 26 5.0 5 75 1501 15 10-- 0 3 SS SS c o � d o CL N c, C7 c N U C7 3 0 D o E E J aa) a Z J L L n a a 8 o � N n aE v a� o E m o E m Ev m a� o y m a� � 0 0 o n as in o o cn cn z W rn o O in r— c� v _, a a° 03 1 SS 18 2.5 2 SS 26 5.0 5 75 1501 15 10-- 0 3 SS SS 7 7 4 ©®111■�� 150115 Depth to Groundwater * Noted on Drilling Tools 13.0 ft. f At Completion (in augers 1) 3.0 ft 9 At Completion (open hole) NA ft _T After NA hours NA ft. 1 After NA hours NA ft _V Cave Depth NA ft N N E m Boring Method HSA - Hollow Stem Augers CFA - Continuous Flight Augers DC - Driving Casing MD -Mud Drilling Page 1 of 1 7606 Whitehall Executive Center Drive TEST BORING -LOG FIAT Charlotte, NC 28273 ® 704-529-3200 Fax 704-529-3272 CLIENT ATC Group Services, LLC BORING # B-10 PROJECT NAME Weddington-Matthews, Geotechnical Phase JOB # 199HOP1710 PROJECT LOCATION Hemby Road DRAWN BY JL Weddington, North Carolina APPROVED BY JIGS DRILLING and SAMPLING INFORMATION TEST DATA Date Started 6/28/17 Hammer Wt. 140 lbs Date Completed 6/28/17 Hammer Drop 30 in. Drill Foreman RDL Spoon Sampler OD 2 in. Inspector MB Rock Core Dia. NA in Boring Method HSA Shelby Tube OD NA in. cn �L °o o 0 0 a) 2 0 E n a7 a) (n q__ (4) o N c o v J O` c SOIL CLASSIFICATION a J j a ) E �s z o a a a>0 o -hoz w a a d) `as E SURFACE ELEVATION `� ani aai m o m m aa) o 0 f0 4) in D a o Q� o a U) 0 o rn U) z U) rn T_ E- C7 U 2 � d 8" TOPSOIL 07 SS 13 Stiff reddish brown sandy SILT with some clay 1 2.5 Very stiff reddish brown and tan sandy SILT SS X 20 2 5- SS 22 3 75 Loose tan and gray silty SAND SS 10 4 100 10 BORING TERMINATED Sample Type SS -Driven Split Spoon ST - Pressed Shelby Tube CA - Continuous Flight Auger RC - Rock Core CU - Cuttings CT - Continuous Tube Depth to Groundwater ! Noted on Drilling Tools Dry ft. f At Completion (in augers) Dry ft. At Completion (open hole) NA ft 3 After NA hours NA ft. X After NA hours NA ft _V Cave Depth NA ft. Boring Method HSA - Hollow Stem Augers CFA - Continuous Flight Augers DC - Driving Casing MD -Mud Drilling Page 1 of 1 uu7j 0860 ` �f 3095Pr 860 Excise Tax $None I Recording Time, Book and Page 26963 -.-M Tax Lot No. 06-120-002B Parcel Identifier No Verified by County on the _ day of 20_ by Mail after recording to Griffin, Smith, Caldwell, Helder & Lee, P.A. (emw) This instrument was prepared by Jake C. Helder Brief Description for the index NORTH CAROLINA GENERAL WARRANTY DEED , 2003, by and GRANTOR REBECCA HEMBY JONES, widow GRANTEE JASON N. SIMPSON 5532 Matthews-Weddington Road Weddington, NC 28104 Enter in appropriate block for each party name, address, and, if appropriate, character of entity, e.g., corporation or partnership The designation Grantor and Grantee as used herein shall include said parties, their heirs, successors, and assigns, and shall include singular, plural, masculine, feminine or neuter as required by context. WITNESSETH, that the Grantor, for a valuable consideration paid by the Grantee, the receipt of which is hereby acknowledged, has and by these presents does grant, bargain, sell and convey unto the Grantee in fee simple, all that certain lot or parcel of land situated in Sandy Ridge Township, Union County, North Carolina and more particularly described as follows: BEGINNING at a railroad spike east of the center line of Matthews-Weddington Road (State Road #1344), in a line of property of the Herman Hemby Heirs; thence with a line of the said Hemby heirs property North 65 degrees 06 minutes West 606.7 feet to an iron, passing an iron in the westem right of way line of the road at 35.0 feet; thence North 06 degrees 21 minutes East 118.65 feet to an iron, a comer of the Billy Joe Simpson property designated as Lot #2; thence with a line of the said Billy Joe Simpson property South 68 degrees 54 minutes East 63147 feet to another point within the right of way of Matthews-Weddington Road, passing an iron in the western right of way line of the road at 600.17 feet; thence South 19 degrees 35 minutes West 155.0 feet to the point of BEGINNING, containing 1.91 acres, more or less, and being designated as Lot #1 on a plat of property of Rebecca Hemby Jones by William J. Alexander, NCRLS, dated December 5, 1975. N. C Bar Assoc. Form No. 3 ® 1977 Printed by Agreement with the N C. Bar Assoc.#003 �u70 0861 RK3095PG861 The property hereutabove descnbed was acquired by Grantor by instrument recorded in Book , Page . A map showing the above described property is recorded in , . TO HAVE AND TO HOLD the aforesaid lot or parcel of land and all privileges and appurtenances thereto belonging to the Grantee in fee simple. And the Grantor covenants with the Grantee, that Grantor is seized of the premises in fee simple, has the right to convey the same in fee simple, that title is marketable and free and clear of all encumbrances, and that Grantor will warrant and defend the title against the lawful claims of all persons whomsoever except for the exceptions hereinafter stated Title to the property hereinabove descnbed is subject to the following exceptions - Rights of way for roads and utilities that might border or cross the above described property. IN WITNESS WHEREOF, the Grantor has hereunto set his hand and seal, or if corporate, has caused this instrument (d e signed in its corporate name by its duly authorized officers and its seal to be hereunto affixed by authonty of its Board of Direct � ' id year first above wntten. ,.�r „�' (Corporate Name) By. President Hemby Jones h � 1't�'hLi1;lpitritt �t (SEAL) ATTEST: (SEAL) Secretary (Corporate Seal; _ (SEAL) NORTH CAROLINA, Union County. SEAL. STAMP 1, the undersigned, a Notary Public of the County and State aforesaid, certify that Rebecca Hemby Jones, widow, Grantor, personally appeared before me flus day and acknowledged the execution of the foregoing instrument Witness my hand and official stamp or seal, this '7'0 day of MAY 2003.. My commission expires: Notary Ablic NORTH CAROLINA, Union County. SEAL -STAMP I, the undersigned, a Notary Public of the County and State aforesaid, certify that personally came before me this day and acknowledged that he/she is Secretary of , a North Carolina corporation, and that by authonty duly given and as the act of the corporation, the foregoing instrument was signed in its name by its President, sealed with its corporate seal and attested by hun/her as its Secretary Witness my Band and official stamp or seal, this day of , 2002 My commission expires - Notary Public The foregoing Certifrcatek'of lbau V d. �yU� n P islare certified to be correct This instrument and this certificate are duly registered at the date and time and in the Book and Page shown on the first page hereof. JUDY G. PRICE REGISTER OF DEEDS FOR UNION COUNTY By L d Deputy/Assi�rt-Register of Deeds N C. Bar Assoc. Form No. 3 0 1977 Printed by Agreement with the N.C. Bar Assoc.#003 4163 BK4l63PG0522 FILED 6522 UNION COUNTY CRYSTAL CRUMP REGISTER OF DEEDS FILED May 17, 2006 AT 09.15 am BOOK 04163 START PAGE 0522 END PAGE 0524 INSTRUMENT # 21468 EXCISE TAX (None) EJC ------------ ----SPACE ABOVE THIS LINE FOR RECORDER'S USE QUITCLAIM DEED TITLE OF DOCUMENT EXCISE TAX: $0.00 PARCEL NO: 06120003 After Recording Mail To: Mail Tax Statements To: This Instrument Prepared By: American Family 011ie H. Manus Law office of Robert Train Prepaid Legal Plan 5009 Hemby Road 964 East Street 1 Centerview Drive Matthews, NC 28105 Suite 209 Suite 102 P.O. Box 1546 Greensboro, NC 27407 Pittsboro, North Carolina 27312 THIS DEED OF GIFT made this r day of 1i� `7 , 2AL, by and between 011ie H. Manus, a widow, hereinafter calleA GRANTOR, AND 011ie H. Manus, Trustee of The 011ie H. Manus Revocable Trust, hereinafter called GRANTEE, WHOSE address is: 5009 Hemby Road, Matthews, North Carolina 28105. WITNESSETH: That the GRANTOR, as a DEED OF GIFT, has bargained and sold, and by these presents does bargain, sell, remise, release, and forever quitclaim unto the GRANTEE, his heirs and/or successors and assigns, premises in Sandy Ridge Township, Union County, North Carolina, described as follows: First Tract: BEGINNING at an iron stake on a line of the 13.40 acre tract, being S. 80 degrees 30 Min. W. 300 feet from the beginning corner of said tract and runs thence 4 new lines, 1- N. 80 degs. 30 min. W. 344 feet to an iron stake; 2nd N. 31 degs. 15 min. W. 161 feet to an iron stake; 3rd S. 88 degs. 15 min. W. 1096 feet to an iron stake; 4th S. 4 degs E. 421 feet to an iron stake, a corner of the 13.40 acre tract; thence with line of said tract N. 80 degs. 30 min. E. 1507 feet to the BEGINNING and containing 9.35 acres, as surveyed by Ralph W. Elliott, Surveyor, June 28th, 1958. This being the same property conveyed to Herman L. Hemby by R. S. Morris and wife, Ola Lee Morris, said deed being recorded in Book 108, Page 569, Registry of Union County. Second Tract: BEGINNING at an iron stake in the E. S. DeLaney line with the H. L. Hemby property and runs thence the Hemby property lines, First - North 80 degs. 30 min. East 505 ft. to an iron. Second - South 42 degs. E. 1461.1 ft. more or less to an iron, a new corner in the center line of the proposed transmission power line; thence along and with the center of the proposed transmission power line North 72 degs. 1 min. West 531.1 ft. to an iron in the old line with Mrs. Lottie Hemby Morris property North 33 degs. 30 min. 4163 BK4I63PGO523 0523 West 644 ft. more or less to a stone; thence South 61 degs. 30 mins. West 704.0 feet to a stone in the E. S. Delaney line; thence with the Delaney line due North 655 feet to the point of BEGINNING and containing 12.35 acres more or less as surveyed by O. J. Byrnes, Feb. 16, 1959, and being a portion of the 17 acre tract deeded to S. F. Hemby by Lillie Wolfe Hemby by deed recorded in Book 115, Page 331 Registry of Union County. For further reference see deed from S. F. Hemby and wife Elbridge C. Hemby to Herman L. Hemby recorded in Book 152, Page 362 Registry of Union County. Third Tract: BEGINNING at a stake (iron) on the East side of the Matthews Road L. W. Whippie and W. L. Cox property corner, also a corner of Mrs. Rebecca Hemby Jones 13.65 acre tract, and runs thence with said road and with W. L. Cox line S. 23 degs. 30 min. W. 430 feet to a point in said road, a little to the west of the center line of said road, a corner of S. F. Hemby's 17 acre tract indicated by an iron stake in range of the next line and west side of the road; thence, with the North line of S. F. Hemby's 17 acre tract N. 42 degs. W. 1930 feet to a stake on H. L. Hemby's line; thence, with his line N. 80 degs. 30 mins. East 375 feet to an iron stake on said line, a corner of Mrs. Rebecca Hemby Jones' 13.65 acre tract; thence, with the south line of her tract S. 44 degs. 30 min. E. 1555.5 feet to the BEGINNING containing 14 acres as surveyed by Ralph W. Elliott, Surveyor, June 19, 1951. For further reference see deed from Russell L. Goodwin and wife, Elaine Hemby Goodwin to Herman Hemby recorded in Book 127, page 356 Registry of Union County. Fourth Tract: BEGINNING at an iron stake, R. S, Morris' corner and runs thence with his lines 19t N. 61 degs. 30 min. E. (crossing the Monroe Road) 379.5 feet to an iron stake in a field; 2nd S. 41 degs. E. 330 feet to a stake in W. edge of the Matthews Road and N. side of the Monroe Road, W. J. Morris' corner; thence with W. J. Morris' lines, 1st S. 13 degs. W. 201 feet to a point on the W. shoulder of the Matthews Road; 2nd S. 18 degs. 15 mins. W. 468 feet to a point in the center of the Matthews Road, A corner of Mrs. Rebecca Hemby Jones' 13.65 acre tract, indicated by an iron stake in range of next line W. side of the Road; thence with the North line of said 13.65 acre tract N. 50 degs. 30 min. W. 997 feet to an iron stake, on H. L. Hemby's line of another tract; thence with said line N. 80 degs. 30 min. E. (passing said Hemby's corner at 102 feet and with R. S. Morris line) 402.5 feet to the BEGINNING and containing 9.80 acres, as surveyed by Ralph W. Elliott, June 19th, 1951, and the grantors and the grantee are all of the heirs at law and next of kin of the said W. Scott Hemby. The widow, Mrs. Lillie Wolfe Hemby joined the deed for the purpose of conveying her dower interest in same. See deed recorded in Book 115, Page 334, Registry of Union County. LESS AND EXCEPTING THE FOLLOWING: The parts of Tract No. 4 Tract previously deed to R. S. Morris of 2/ 10 of an acre, and part of Tracts 3 and 4 deeded to Rebecca Hemby Jones, and part of Tract No. 3 deeded to Scott Franklin Hemby, and portion deeded to H. L. and 011ie M. Hemby by deed recorded in Book 179, Page 194 Registry of Union County. EXCEPT for all property sold to Ricky Lee Helms on April 14, 2000, in deed recorded at the Union County Register of Deeds office in Book 1379, Page 493, more commonly known as: Parcel no. 06120003B; 3.34 acres. Prior Recorded Doc. Ref.: Deed: Recorded: September 30, 1963; BK 186, PG 562 Subject To: Restrictions, Conditions, Covenants, Rights, Rights of Way, and Easements now of record, if any. 416:1 0524 BX4I63PG0524 TO HAVE AND TO HOLD the above described premises with all the appurtenances thereunto belonging, or in any wise appertaining, unto the GRANTEE, his heirs and/or successors and assigns forever. When reference is made to the GRANTOR or GRANTEE, the singular shall include the plural and masculine shall include the feminine or the neuter; IN WITNESS WHEREOF, the GRANTOR has caused this deed to be executed the day and year first above written. r 011ie H. Manus ACKNOWLEDGMENT STATE OF V G ) COUNTY OF Ctii-'-v-- ) ss 1,Z GC- Q , do hereby certify that 011ie H. Manus personally appeared before me this day and acknowledged the due execution of the foregoing instrument. NOTARY STAMP/SEAL Michael B. Sloop Notuy Public Cabm,nd County, NC My eo..n. !on expmn 3-19.201 WITNESS my hand and official seal this the day of C , A.D., 20-02-0 NOTARY PUBLIC MY Commission Expires: 3 . ly_ `�% Z0001/0003 31 FAX FILED UNION COUNTY CRYSTAL CRUMP REGISTER OF DEEDS FILED Feb 21, 2008 AT 10:22 am BOOK 04812 START PAGE 0888 END PAGE 0890 INSTRUMENT # 06044 EXCISE TAX (None) SKH Excise Tax: S -0 - Tax Lot No. Parcel Identifier No. 09-174-068 Verified by County on the _ day of , 2005 by Mail after recording to Grantee. This mstrument was prepared by Cynthia J. Robinson, Esq. Brief description for the Index: Lot 5, Country Haven, Flat Cab. B, File 337A NON -WARRANTY DEED AND , , SEL `ASE OF MARITAL INTEREST This decd made the day of , �008, by and between GRANTOR GRANTEE DANIELLE K. WHITE, married JOSEPH R. WHITE, JR., married Mailing address: 505 Baucom Deese Road Monroe, NC 28110 WITNESSETH, for and in consideration of the sum of One Dollar and other good and valuable consideration paid by Grantee to Grantor, the receipt of which is hereby acknowledged, Grantor has released, remised and forever quitclaimed and does herby release, remise and quitclaim unto Grantee all such right, title and interest as Grantor may have in and to that certain tract or parcel of land situate in the City of Unionville, Monroe Township, Union County, State of North Carolina and pore particularly described as follows: Being all of Lot 5 of COUNTRY HAVEN, as shown on plat recorded in plat Cabinet B, File 337A, Union County Public Registry, reference to which is hereby made for a more particular description. The property hereinabove described was acqu red by Grantor by inset ment recorded in Book 3721, Page 507. A map showing the above described property is recorded in Plat Cabinet B, File 337A. 4812 _ 0889 - FAX 1W, This conveyance is made pursuant to and in accordance with the provisions ofN.C.G.S. 39-13.3{e} and 52- 10 for the purpose of vesting sole ownership in Grantee and for this purpose, Grantor does hereby waive, release, quitclaim and renounce unto Grantee all and every right to a share in the estate of Grantee upon Grantee's death as provided in N.C.G.S. 29-14, and all other rights and interest in said real estate which Grantor now has or would hereafter have arising out of or accruing to Grantor by reason of the marital relationship of Grantor and Grantee. By execution of this deed, Grantor does hereby release, convey, and quitclaim forever all and any marital rights Grantor may presently or in the future have in or to the described real property resulting from the marriage between Grantor and Grantee, including specifically, but not limited to, the right to claim as elective life estate in the real property described, and a right to claim a marital property interest in the described property. Joseph �. wh�k,Jr,, as Grantee, joins in the execution of this instnunent in order to comply with the requirements ofN_C_G_S. Section 52-10. TO HAVE AND TO HOLD the above-described premises unto Grantee, his heirs and assigns, forever with all appurtenances thereunto belonging, or in anywise appertaining. When reference is made to Grantor or Grantee, the singular shall include the plural and the masculine shall include the feminine or neuter. IN WITNESS WHEREOF, Grantor has hereunto set his hand and seal, the day and year first above written. SEAL -STAMP DONALD J. BUTLER NOTARY PUBLIC UNION COUNTY NORTH CAROLINA My Com=won Expires September 12, 2011 NORTH CAROLINA, (.tilI c County L a Notary Public of the County and State aforesaid, certify that C. WHITE, Grantor, personally appeared before me this day and acknowledged the execution of the foregoing instri went. Witness my band and official stamp or seal, this 15- day ofJan=3- 2008. Notary Pu My commission expires: / Z/zc, t l F-,3 I 4812 - [a 0003/0003 0*390 11:33 FAY SEAL -STAMP NORTH CAROLINA, 0,4J4610 County I, a Notary Public of the County and State aforesaid, certify that JOSEPH R. WHITE, JR., Grantee, personally appeared before me this day and acknowledged the execution of the foregoinginstrument. Witness my hand and official stamp or seal, this - 4ay of basaary, Plr. } iacp iv 2008. Ey THIA J ROBINSON MAWPUBM a= , Worth Oa OSfib+ Egim parch 27,02 Notary lic My commission expires: The foregoing certificate of islare certified to be correct This instrument and this certificate are duly registered at the date and time and in the Book and Page shown on the first page hereof Register of Duds for By: ` Deputy/Assistant Register of Dceds County