Loading...
HomeMy WebLinkAboutNC0060623_Compliance Evaluation Inspection_20170719I? aterRest urce'S Ei4°di[;ORKENTAt WALITY July 19, 2017 Sterling A. Weaver 149 Sunset Blvd Beaufort, SC 29902 Subject: Compliance Evaluation Inspection Report NPDES Permit NCO060623 Stone Highway MHP, Rockingham County Dear Mr. Weaver: ROY COOPER carom rr MICHAEL S. RECAN Secretary S, JAS' ZIMM RMAN Diretlff RECEIVEMCDEQI WR AUG -1 2017 Water Quality Permitting Section On July 11, 2017, Paul DiMatteo of the Division of Water Resources ("Division"), Winston-Salem Regional Office conducted a Compliance Evaluation Inspection of the above referenced wastewater treatment system. Marc Nault, Operator in Responsible Charge (ORC), and David Merritt, backup ORC, were present for the inspection. An inspection summary follows and an inspection report is attached for your records. Site Review 1. Permit The current permit became effective on June 1, 2017 and expires on April 30, 2022. A copy of the current permit was not available for review — one should be kept for inspection. Permitted components include an aeration basin, clarifier, and chlorine disinfection. 2. Facility Site Review No discrepancies between the permitted components and the facility were observed. 3. Operation and Maintenance All components appeared to be functioning properly. The ORC or a properly designated backup visits the site as required. Visitation logs were current and available during the inspection. During the inspection, it was noted that portions of the plant were beginning to corrode. Although the corrosion did not appear to allow any bypasses of treatment processes, the facility should be maintained so that such a bypass will not occur. 4. Flow Measurement The permit requires continuous flow measurement at the influent or effluent. The flow meter was last calibrated on January 4, 2017 by Carolina Technical Services. State of North Carolina I Environmental Quality I Water Resources 450 West Hanes Mill Road. Suite 300. Winston-Salem. NC 27105 5. Effluent/Receiving Waters The effluent is discharged into an unnamed tributary to Buffalo Creek. A path to the outfall is maintained and the outfall was accessible during the inspection. Effluent appeared clear with no visible impact to the receiving stream. Documentation Review Records/Reports Discharge Monitoring Reports (DMRs) and lab data are maintained according to the permit. DMRs include all permit parameters. Copies of DMRs, operator visitation logs, lab reports and Chain -of -Custody forms were available for review during the inspection. 7. Self -Monitoring Program A review of DMRs from January, 2016 through May, 2017 showed no violations, and a comparison of submitted DMR data and field records showed no errors or concerns. 8. Laboratory All required parameters are measured by Meritech, Inc. under certification # 165. All effluent samples are taken from the outfall. Chain -of -custody forms were complete and available for all parameters measured off site. Records for parameters measured on-site were complete. Upstream and downstream samples are taken as required. 9 Sludge Handling Disposal Sludge is removed from the plant as needed. Sludge was recently removed by Billingsley Septic Tank Company in February, May and June, 2017. Invoices were available for review. We appreciate your efforts in effectively operating and maintaining this treatment system. No additional response to this report is required If you should have any questions, please do not hesitate to contact Paul DiMatteo at (336) 776-9691 or our office at (336) 776-9800. Sincerely, `1/ W�e"' Sherri V. Knight, P.E., Regional Supervisor Water Quality Regional Operations Section Winston-Sa'em Regional Office Division of Water Resources, NCDEQ Enclosures — Inspection Report and Summary CC: Marc Nault, David Merritt — by email WQS Winston-Salem Regional Office - Enforcement File NPDES Compliance/Enforcement Unit - Enforcement File Central Files State of North Carolina I Ervironmental Quality I Water Resources 450 West Hanes Mill Road, Suite 300, Winston-Salem, NC 27105 United States Environmental Protection Agency Form Approved EPA Washington, D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A National Data System Coding (i e , PCs) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I NC0060623 I11 12 17/07/11 17 18 [Sj 19 L S j 20I I 2111111�-1111111 1 111 1 11111111111111 1 11111111 f6 Inspection Work Days Facility Self-Monitoring Evaluation Rating 131 QA -----Reserved — 67 70 LJI 71 itJI 72 LN_73I74 75 1 1 1 1 j_Lj80 Section B Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Permit Number) 01 OOPM 17/07/11 17/06/01 Stone Highway Mobile Home Park 311 Pinewood PI Exit Time/Date Permit Expiration Date Eden NC 27288 02 05PM 17/07/11 22/04/30 Name(s) of Onsite Rep resentative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Sterling A Weaver, 149 Sunset Blvd Beaufort SC 29902//843-522-8882/8435228882 No Section C Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self-Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Laboratory Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Paul DiMatteo WSRO WQ//336-776-9691/ 7�g1?O�7 ?�-Q �'�,/ uc Signature of Management Q AA Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete Page# NPDES yr/mo/day Inspection Type (Cont.) 31 Nco060623 111 121 17/07/11 1 17 18 IC Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Site Review 1 Permit The current permit became effective on June 1, 2017 and expires on April 30, 2022. A copy of the current permit was not available for review — one should be kept for inspection. Permitted components include an aeration basin, clarifier, and chlorine disinfection. 2. Facility Site Review No discrepancies between the permitted components and the facility were observed. 3. Operation and Maintenance All components appeared to be functioning properly. The ORC or a properly designated backup visits the site as required. Visitation logs were current and available during the inspection. During the inspection, it was noted that portions of the plan: were beginning to corrode. Although the corrosion did not appear to allow any bypasses of treatment processes, the facility should be maintained so that such a bypass will not occur. 4. Flow Measurement The permit requires continuous flow measurement at the influent or effluent. The flow meter was last calibrated on January 4, 2017 by Carolina Technical Services. 5. Effluent/Receiving Waters The effluent is discharged into an unnamed tributary to Buffalo Creek. A path to the outfall is maintained and the outfall was accessible during the inspection. Effluent appeared clear with no visible impact to the receiving stream. Documentation Review 6. Records/Reports Discharge Monitoring Reports (DMRs) and lab data are maintained according to the permit. DMRs include all permit parameters. Copies of DMRs, operator visitation logs, lab reports and Chain -of -Custody forms were available for review during the inspection. 7. Self -Monitoring Program A review of DMRs from January, 2016 through May, 2017 showed no violations, and a comparison of submitted DMR data and field records showed no errors or concerns. 8. Laboratory All required parameters are measured by Meritech, Inc. under certification # 165. All effluent samples are taken from the outfall. Chain -of -custody forms were complete and available for all parameters measured off site. Records for parameters measured on-site were complete. Upstream and downstream samples are taken as required. 9. Sludge Handling Disposal Sludge is removed from the plant as needed. Sludge was recently removed by Billingsley Septic Tank Company in February, May and June, 2017. Invoices were available for review. Page# Permit NCO060623 Inspection Date 07/11/2017 Owner - Facility: Stone Highway Mobile Home Park Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? N ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable N ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Settleable solids. Some corrosion was observed. Allowing corrosion to continue may be detrimental to the plant's ability to properly treat waste. Permit Yes No NA NE (If the present permit expires in 6 months or less) Has the permittee submitted a new ❑ ❑ N ❑ application? N ❑ ❑ ❑ Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment. Record Keepinq Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? N ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? 0 ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? 0 ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported CDCs Are DMRs complete do they include all permit parameters? 0 ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ ❑ on each shift? Is the ORC visitation log available and current? 0 ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? E ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? 0 ❑ ❑ ❑ Page# 3 Permit. NCO060623 Owner - Facility: Stone Highway Mobile Home Park Inspection Date: 07/11/2017 Inspection Type Compliance Evaluation Record Keeping Yes No NA NE Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 ❑ Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amount3 and other debris? E ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ E ❑ Comment* Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? N ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment: Calibrated by Carolina Technical Services on January 4, 2017. Bar Screens Yes No NA NE Type of bar screen Ext. Air Type of aeration system a.Manual Is the basin free of dead spots? 0 ❑ b Mechanical ❑ Are surface aerators and mixers operational? ❑ ❑ M Are the bars adequately screening debris? 0 ❑ ❑ ❑ Is the screen free of excessive debris? E ❑ ❑ ❑ Is disposal of screening in compliance? ❑ ❑ ❑ Is the unit in good condition? ❑ ❑ ❑ Comment - Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? 0 ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ M ❑ Are the diffusers operational? E ❑ ❑ ❑ Page# 4 I Permit: NCO060623 Inspection Date: 07/11/2017 Aeration Basins Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/1) Comment: Owner - Facility: Stone Highway Mobile Home Park Inspection Type Compliance Evaluation Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately % of the sidewall depth) Comment: Disinfection -Tablet Are tablet chlorinators operational? Are the tablets the proper size and type? Number of tubes in use? Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de -chlorination? Comment. De -chlorination Type of system ? Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ N ❑ ❑ ❑ E Yes No NA NE N ❑ ❑ ❑ ❑ ❑ ■ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ N ❑ ❑ ❑ N ❑ ❑ ❑ E ❑ ❑ ❑ ■ ❑ ❑ ❑ N ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ 3 ❑ ❑ ❑ ■ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ Yes No NA NE Tablet Page# 5 Permit: NCO060623 Owner - Facility Stone Highway Mobile Home Park Inspection Date 07/11/2017 Inspection Type- Compliance Evaluation De -chlorination Yes No NA NE # Is de -chlorination substance stored away from chlorine containers? 0 ❑ ❑ ❑ Comment Are the tablets the proper size and type? 0 ❑ ❑ ❑ Are tablet de -chlorinators operational? M ❑ ❑ ❑ Number of tubes in use? 2 Comment Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? 0 ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? M ❑ ❑ ❑ # Is the facility using a contract lab? M ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ 0 Celsius)? ❑ ❑ ❑ Incubator (Fecal Coliform) set to 44 5 degrees Celsius+/- 0.2 degrees? ❑ ❑ ❑ M Incubator (BOD) set to 20.0 degrees Celsius +/-1.0 degrees? ❑ ❑ ❑ 0 Comment. All parameters by Meritech. Inc. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ M ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? ❑ ❑ M ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type 0 ❑ ❑ ❑ representative)? Comment: Samples taken from the outfall. Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, and 0 ❑ ❑ ❑ sampling location)? Comment: Page# 6