Loading...
HomeMy WebLinkAbout20081442 Ver 1_More Info Letter_20081006W A rF9 Michael F. Easley, Governor William G. Ross Jr., Secretary ??- North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality October 6, 2008 DWQ Project # 08-1442 Wake County CERTIFIED MAIL: RETURN RECEIPT REQUESTED Mr. Julian Prosser City of Raleigh One Exchange Plaza, Suite 304 Raleigh, NC 27601 Subject Property: Wake County Leesville Branch Library Ut to Turkey Creek [030402, 27-33-2, C, NSW] REQUEST FOR MORE INFORMATION Dear Mr. Prosser: On September 19, 2008, the Division of Water Quality (DWQ) received your "Courtesy Copy" application dated August 22, 2008, to fill or otherwise impact 20 linear feet of perennial stream, 30 linear feet of intermittent stream (20 linear feet permanent impact and 10 linear feet temporary impact), and 3,759 square feet of Zone 1 Neuse River basin protected riparian buffers and 2,161 square feet of Zone 2 Neuse River basin protected riparian buffers to construct the proposed public library at the site. The DWQ has determined that your application was incomplete and/or provided inaccurate information as discussed below. The DWQ will require additional information in order to process your application to impact protected wetlands and/or streams on the subject property. Therefore, unless we receive five copies of the additional information requested below, we will place this project on hold as incomplete until we receive this additional information. If we do not receive the requested information, your project will be formally returned as incomplete. Please provide the following information so that we may continue to review your project. Additional Information Requested: 1. Your proposed impacts under General Certification No. 3699 (which corresponds to USACE Nationwide Permit No. 12) require written concurrence from the NCDWQ. Please submit 5 copies of your application, all related maps and plans, and a check for the application fee of $240.00. 2. Please verify that the USACE will be permitting your project under a Nationwide Permit No. 12 and not a Nationwide Permit No. 39. 3. Please discuss what installation method will be utilized for installation of the proposed sewer lines. . 4. Per the requirements of the Neuse River Basin Riparian Buffer Rule, you must show that this site meets diffuse flow requirements with a level spreader or other BMP per Chapter 8 of the BMP Manual (see http://h2o.enr,state.ne.us/su/bmp forms.htm). Please note, if the slope from the proposed level spreader(s) lip to the top of bank of the stream exceeds the allowable slope for level spreaders (6% for wooded vegetation and 8% for thick ground cover and grass). You must 401 Oversight/Express Review Permitting Unit 1650 Mail Service Center, Raleigh, North Carolina 27699-1650 2321 Crabtree Boulevard, Suite 250, Raleigh, North Carolina 27604 Phone: 919-733-1786 / FAX 919-733-6893 / Internet: http://112o.enr.state.11c.us/ncwet]ands None hCarohna Naturally An Equal Opportunity/Affirmative Action Employer - 50% Recycled/l0% Post Consumer Paper City of Raleigh Page 2 of 2 October 6, 2008 either relocate the level spreader(s) to a location where the filter strip slope(s) is/are appropriate or provide a BMP that removes 85 percent TSS and 30 percent TN and TP. 5. Please re-submit your site plans on full plan sheets at a scale of no smaller than 1 "=50' with topographic contours shown. 6. Please note, your proposed impacts cannot occur until the DWQ receives your stormwater BMP management approval from the City of Raleigh. Please submit this information within 30 calendar days of the date of this letter. If we do not receive this requested information within 30 calendar days of the date of this letter, your project will be withdrawn and you will need to reapply with a new application and a new fee. This letter only addresses the application review and does not authorize any impacts to wetlands, waters or protected buffers. Please be aware that any impacts requested within your application are not authorized (at this time) by the DWQ. Please call Ms. Cyndi Karoly or Mr. Ian McMillan at 919-733- 1786 if you have any questions regarding or would like to set up a meeting to discussthis matter. Sincerely, Jt/CVyndi Karoly, Supervisor 401 Oversight/Express Review Permitting Unit CBK/?m cc: Lauren Witherspoon, DWQ Raleigh Regional Office USACE Raleigh Regulatory Field Office File Copy Matt Matthews, DWQ Branch Manager Johnny Edwards, John A. Edwards & Co., 333 Wade Avenue, Raleigh, NC 27605 Filename: 081442 W akeCo u ntyLeesvilleBra nchLi brary(W ake)On_Hold ¦ Complete items 1, 2, and 3. Also complete item 4 if Restricted Delivery Is desires] ¦ Print your name and address on the reverse so that we can return the card to you. ¦ Attach this card to the back of the mailpiece, or on the front if space permits. 1. Article Addressed to: City of Raleigh Attn: Mr. Julian Prosser One Exchange Plaza, Suite 304- Raleigh, NC 27601 DWQ# 08-1442-Wake B. Received by (Printed Nar/e) C. Date of livery ", !Y i_ 6. Is delivery address different from item 1? ? Yes If YES, enter delivery address below: ? No 3. Service Type P Certified Mail ? Express Mail ? Registered jf? Return Receipt for Merchandise ? Insured Mail !? C.O.D. 4. Restricted Delivery? (Extra Fee) ? Yes 2. Article Number 7008 1300 0001 2224 8958 (Transfer from service labug UNITED STATES POSTAL SERVICE • Sender: Please print your name, address, and ZIP+4 in this box • NC DENR Division of Water Quality 401 Oversight/Express Unit 2321 Crabtree Boulevard, Suite 250 Raleigh, NC 27604 First-Class Mail Postage 8 Fees Paid USPS Permit No. G-10