Notice of Violation
Compliance Evaluation Inspection
NOV-2017-PC-0445
Belmont Textile Machinery Company WWTP
NPDES Permit No. NCO037371
Gaston County
Enclosed is a copy of the Compliance Evaluation Inspection for the inspection conducted at
the subject facility on July 5, 2017 by Ori Tuvia. Joseph Cote's cooperation during the site visit was
much appreciated. Please advise the staff involved with this NPDES Permit by forwarding a copy of
the enclosed report.
The main area of concern observed during the inspection was that at the time of the
inspection both blower/motor units were not operational and the plant was running on undersized
backup blower. Due to the undersized blower, the settablelty of solids at the time of the inspection
was very low about 72% after 15 minutes. As per your permit, the facility must have 2 operational,
properly sized blowers/motors.
Additional areas of concern observed during the inspection were:
1) There are safety concerns about the lack of adequate grating and railing installed at the
chlorine contact/dechlorination areas. No railings were observed at the specified area at the
time of the inspection.
2) The laboratory instrumentation used for residual chlorine field analyses had failed the 10
ug/L parameter of the past chlorine curve. The instrument chlorine curve should be redone.
Mooresville Regional Office
Location 610 East Center Ave, Suite 301 Mooresville, NC 28115
nom___ r-rnn nnn nnnn i -- 1-1 n -- 11en
You are requested to respond in writing within 10 days of receipt of this Notice detailing
a plan of action as to how the facility will return two properly sized blowers/motors to
immediate service.
The report should be self-explanatory; however, should you have any questions concerning
this report, please do not hesitate to contact Ori Tuvia at (704) 235-2190, or at
ori.tuvia@ncdenr.gov.
Sincerely,
W. Corey Basinger
Regional Supervisor
Mooresville Regional Office
Division of Water Resources
Cc. NPDES Unit
MRO Files
United States Environmental Protection Agency
Form Approved
EPA Washington, D C 20460
OMB No 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A National Data System Coding (i e, PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN 1 2 15 1 3 I NCO023540 I11 12 17/07/05 17 181,.1 191 G I 201 I Lfi
21111111 1111111 11 11 1 11 1111 1 1 11111 111111111 1_1 �6
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA — Reserved -
74 751 I I I [ I80
67 10 70 [, j 71 1 N J 1 72 I N I 731 I 1 A
lJ L_J I I I
Section B FacilityData
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES permit Number)
09 15AM 17/07/05
15/05/01
Belmont Textile Machinery WWTP
1212 W Catawba Ave
Exit Time/Date
Permit Expiration Date
Mount Holly NC 28120
11 20A 17/07/05
20/02/29
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
///
Joseph R Cote/ORCr/04-827-5836/
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Walter P Rhyne,PO Box 568 Mount Holly NC 281200168//704-827-5836[7048278551
No
Section C Areas Evaluated During Inspection (Check only those areas evaluated)
Permit 0 Flow Measurement Operations & MamtenancE Records/Reports
Self -Monitoring Program E Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters
Laboratory
Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
On A Tuvia MRO WQ//704-663-1699/
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
W Corey Basinger MRO WQ//704-235-2194/
EPA For 3560-3 (Rev 9-94) Previous editions are obsolete
-�V4 *t,7 -
Page#
NPDES yr/mo/day Inspect on Type
31 NCO023540 I11 12 17/07/05 17 18 ICI
Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Page#
Permit NCO023540 Owner -Facility Belmont Textile Machinery WWfP
Inspection Date 07/05/2017 Inspection Type Compliance Evaluation
Permit
Yes No NA NE
(If the present permit expires in 6 months or less) Has the permittee submitted a new
El
ElEl
❑
❑
application?
E
❑
❑
❑
Is the facility as described in the permit?
0
❑
❑
❑
# Are there any special conditions for the permit?
❑
0
❑
❑
Is access to the plant site restricted to the general public?
0
❑
❑
❑
Is the Inspector granted access to all areas for inspection?
0
❑
❑
❑
Comment The subject permit expires on 2/29/2020.
Record Keeping
Yes No NA NE
Are records kept and maintained as required by the permit?
0
❑
❑
❑
Is all required Information readily available, complete and current?
E
❑
❑
❑
Are all records maintained for 3 years (lab reg required 5 years)?
0
❑
❑
❑
Are analytical results consistent with data reported on DMRs?
0
❑
❑
❑
Is the chain -of -custody complete?
0
❑
❑
❑
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported CDCs
Are DMRs complete do they Include all permit parameters?
0
❑
❑
❑
Has the facility submitted its annual compliance report to users and DWQ?
❑
❑
0
❑
(if the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator
❑
❑
N
❑
on each shift?
Is the ORC visitation log available and current?
❑
❑
❑
Is the ORC certified at grade equal to or higher than the facility classification?
N
❑
❑
❑
Is the backup operator certified at one grade less or greater than the facility classification?
0
❑
❑
❑
Is a copy of the current NPDES permit available on site?
0
❑
❑
❑
Facility has copy of previous year's Annual Report on file for review?
❑
❑
E
❑
Comment The records reviewed during the inspection were organized and well maintained
DMRs,
CDCs, calibration logs and ORC logs were reviewed for the period March 2016 through
April
2017
Operations & Maintenance
Yes No NA NE
Page# 3
Permit NCO023540 Owner - Facility Belmont Textile Machinery WWTP
Inspection Date 07/05/2017 Inspection Type Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? ❑ N ❑ ❑
Does the facility analyze process control parameters, for ex MLSS, MCRT, Settleable ❑ ❑ E ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment The facility appeared to be adequately treating the wastewater at the time of the Inspection
however, at the time of the inspection both blower/motor units were not operational and the
plant was running on undersized backup blower Due to the undersized blower, the
settablelty of solids at the time of the inspection was very low about 72% after 15 minutes
Wastewater solids are removed once per year by Ray's Septic Service Solids were last
removed on 6/13/2017
additionally, there are safety concerns due to the lack of adequate railing/grating at the
chlorine contact/dechlorination areas The permittee should ensure that adequate prating
and railing are Installed at the chlorine contact/dechlonnation areas
Laboratory
Are field parameters performed by certified personnel or laboratory?
Are all other parameters(excluding field parameters) performed by a certified lab?
# Is the facility using a contract lab?
# Is proper temperature set for sample storage (kept at less than or equal to 6 0 degrees
Celsius)?
Incubator (Fecal Coliform) set to 44 5 degrees Celsius+/- 0 2 degrees?
Incubator (BOD) set to 20 0 degrees Celsius +/- 1 0 degrees?
Yes No NA NE
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
E ❑ ❑ ❑
Comment On-site field analyses (PH, total residual chlorine, temperature) are performed under the
facility's field laboratory ,certification # 5479 K&W Labs (Certification #559) has also been
contracted to provide analytical support
The laboratory instrumentation used for residual chlorine field analyses, had failed the 10
uq/L parameter of the past chlorine curve
■❑
0 E
Effluent Sampling
Yes No NA NE
Is composite sampling flow proportional?
❑
❑
0
❑
Is sample collected below all treatment units?
E
❑
❑
❑
Is proper volume collected?
0
❑
❑
❑
Is the tubing clean?
❑
❑
0
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6 0 degrees
N
❑
❑
❑
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
0
❑
❑
❑
representative)?
Comment The subject permit requires effluent grab samples
Bar Screens Yes No NA NE
Page# 4
E
Permit NCO023540
Inspection Date 07/05/2017
Bar Screens
Type of bar screen
Owner -Facility Belmont Textile Machinery wwTP
Inspection Type Compliance Evaluation
Yes No NA NE
a Manual
0
No NA NE
Mode of operation
Ext Air
b Mechanical
❑
Type of aeration system
Diffused
Are the bars adequately screening debris?
❑
0
❑
❑
Is the screen free of excessive debns?
0
❑
❑
❑
- Is disposal of screening in compliance?
0
❑
❑
❑
Is the unit in good condition?
❑
❑
E
❑
Comment The Influent passes through a communitor and a coarse bar screen
prior to the aeration
N
❑
❑
basin
Is the DO level acceptable?
❑
❑
❑
Aeration Basins
Yes
No NA NE
Mode of operation
Ext Air
Type of aeration system
Diffused
Is the basin free of dead spots?
0
❑
❑
❑
Are surface aerators and mixers operational?
❑
0
❑
❑
Are the diffusers operational?
❑
❑
0
❑
Is the foam the proper color for the treatment process?
0
❑
❑
❑
Does the foam cover less than 25% of the basin's surface?
N
❑
❑
❑
Is the DO level acceptable?
❑
❑
❑
0
Is the DO level acceptable?(1 0 to 3 0 mg/1)
❑
❑
❑
0
Comment Doa food Is added as a food supplement five days per week at a minimum) due to the low
Influent flows/loading The facility is equipped with two blower/motor units, however, at the
time of the inspection both blower/motor units were not operational and the plant was
running on undersized backup blower Due to the undersized blower, the settablelty of solids
at the time of the inspection was very low about 72% after 15 minutes
Secondary Clarifier
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
1'lM►r•7i!U1UU=
N ❑ ❑ ❑
❑ ❑ ■ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ E ❑
Page# 5
Permit NCO023540 Owner - Facility
Inspection Date 07/05/2017 Inspection Type
Belmont Textile Machinery WwrP
Compliance Evaluation
Are tablet chlorinators operational?
M
Secondary Clarifier
Yes No NA NE
Is the return rate acceptable (low turbulence)?
0
❑
❑
❑
Is the overflow clear of excessive solids/pin floc?
0
❑
❑
❑
Is the sludge blanket level acceptable? (Approximately % of the sidewall depth)
0
❑
❑
❑
Comment
Disinfection -Tablet
Yes No NA NE
Are tablet chlorinators operational?
M
❑
❑
❑
Are the tablets the proper size and type?
M
❑
❑
❑
Number of tubes in use?
1
M
❑
# Is de -chlorination substance stored away from chlorine containers?
Is the level of chlorine residual acceptable?
M
❑
❑
❑
Is the contact chamber free of growth, or sludge buildup?
0
❑
❑
❑
Is there chlorine residual prior to de -chlorination?
M
❑
❑
❑
Comment.
De -chlorination
Yes No NA NE
Type of system ?
Tablet
Is the feed ratio proportional to chlorine amount (1 to 1)?
❑
❑
0
❑
Is storage appropriate for cylinders?
❑
❑
M
❑
# Is de -chlorination substance stored away from chlorine containers?
❑
0
❑
❑
Are the tablets the proper size and type?
0
❑
❑
❑
Comment The chlorination and dechlorination tablets are stored inside the industrial facility
Are tablet de -chlorinators operational?
M
❑
❑
❑
Number of tubes in use?
1
Comment The chlorinated wastewater is pumped through the dechlor tablet unit prior to the effluent
pumping area
Flow Measurement - Effluent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Comment Instantaneous flows are measured by a dose counter (150 gallons per dose)
Yes No NA NE
❑ ❑ M ❑
❑ M ❑ ❑
❑ ❑ M ❑
❑ ❑ M ❑
Page# 6
W
Permit NC0023540 Owner -Facility
Belmont Textile Machinery WWTP
Inspection Date 07/05/2017 Inspection Type
Compliance Evaluation
Effluent Pipe
Yes No NA NE
Is right of way to the outfall properly maintained?
❑
❑
❑
0
Are the receiving water free of foam other than trace amounts and other debris?
❑
❑
❑
0
If effluent (diffuser pipes are required) are they operating properly?
❑
❑
❑
0
Comment
Page# 7