HomeMy WebLinkAboutNC0003719_Revised Water Balance_20170711July 7, 2017
Ms. Teresa Rodriguez
Permit Writer
N.C. Division of Water Resources
NPDES Permitting
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
Subject: DAK Americas LLC
Cedar Creek Site, Fayetteville, NC
NPDES Permit No. NCO88563242
Dear Ms. Rodriguez:
RECEIVED/KDMVR
JUL 11.2017
water Quality
rMitting Section
DAK Americas submitted its application to renew the Cedar Creek Site's NPDES permit
on May 3, 2016. During a site visit you made on June 14, 2017 you requested that DAK
amend its application by updating the water balance and corresponding information on
the EPA Form 2C to reflect projected operations over the life of the new permit. Please
use the revised water balance, which is enclosed, when developing the site's NPDES
permit.
If you have questions or need additional information, please contact me at (910) 512-
4883 or ewike@dakamericas.com.
Sincerely,
E beth Wike
Senior Environmental Engineer
Cedar Creek Site • 3216 Cedar Creek Road . Fayetteville, NC 28312
910-371-4498 (phone) • 910-512-4883 (mobile) • 910-512-4456 (fax)
www.dakamericas.com
DAK Americas Cedar Creek Site
Water Balance
NPDES Permit No NC088563242
Purchased water from PWC
617 mgdj _
0--004-m-gdF Fire
Ponds
0 175 m Cooling
Tower
Utilities
Deminerahzer
Softener
Boilers
Condensate
to atm
0=004 mgd
line testing
Sanitary
Wastewater
to atm
0133.mgd evaporation
0 042 mgdIBlowdown
DAK
Resins and Batch Plants
CPR
Recycle Bottle Plant
original May 3, 2016
revised July 7, 2017
E Wike
Steam I 0.047 me
condensates 0 055 me
b'065 mac
- --
0127
0 250 mo
Total Influent 0 484 mgd,
Stormwater
0 050 mgdj
Wastewater
Treatment
Plant
Outfall 001
0 092 mqd!
J to atm
0 018 mgd
evaporation
Outfall 002
0 443 mad
0 024 mgd
Sludge
To Cape Fear River
Please or print in the unshaded areas only
typeP Y
EPA ID Number (Copy from Item 1 of Form 1) Form Approved
NCD088563242 OMB No 2040-0086
Approval expires 8-31-98
Form US ENVIRONMENTAL PROTECTION AGENCY
APPLICATION FOR PERMIT TO DISCHARGE WASTEWATER
EXISTING MANUFACTURING, COMMERCIAL, MINING AND SILVICULTURAL OPERATIONS
2 w �� EPA
`
NPDES Consolidated Permits Program
I. Outfall Location
For this outfall, list the latitude and longitude, (degrees, min xxxx) and name of the receiving water(s)
Outfall
Latitude
Longitude
Receiving Water (name)
Number list
Deg
Min
Sec
Deg
Min
Sec
001
34
58
08
78
46
58
Cape Fear River
002
34
58
08
78
46
58
Cape Fear River
Additional outfalls are listed In Table I
II. Flows, Sources of Pollution, and Treatment Technologies
A Attach a line drawing showing the water flow through the facility Indicate sources of intake water, operations contributing wastewater to
the effluent, and treatment units labeled to correspond to the more detailed description In Item B Construct a water balance on the line
drawing by showing average flows between intakes, operations, treatment units, and outfalls If a water balance cannot be determined
(e g, for certain mining activities), provide a pictoral description of the nature and amount of any sources of water and any collection or
treatment measures
B For each outfall, provide a description of (1) All operations contributing wastewater to the effluent, including process wastewater, sanitary
wastewater, cooling water, and storm water runoff, (2) The average flow contributed by each operation, and (3) The treatment received
by the wastewater Continue on additional sheets If necessary
1 Outfall No
2 Operations Contributing Flow
3 Treatment
(list)
a OPERATION (list)
b AVERAGE FLOW
a DESCRIPTION
b LIST CODES FROM TABLE 2C-1
include units
001
Stormwater
0 050 mgd
Stormwater from
Discharge to surface
4-A
Cooling Tower Blowdown
0 042 mild
developed and
undeveloped land
waters
Total
0 092 mgd
throughout the plant
property including the
plant process areas and
cooling tower
blowdown
002
Wastewater Treatment Plant Influent
a) Resins and Batch Plants
b) Sanitary sewers
c) Recycled bottle facility
Sub -total
0 224 mgd
0 005 mgd
0 250 in
0 479 mgd
Treated process
wastewater, sanitary
sewage, cooling tower
blowdown, boiler
blowdown, steam
condensate
Mixing
Activated Sludge
Discharge to surface
waters
Aerobic Digestion
Drying Beds
1-0
3-A
4-A
5-A
5-H
less
Evaporation
0 012 mgd
Sedimentation
Neutralization
1-U
2-K
Water in sludge
0 024 mgd
Total Effluent
0 443 mgd
EPA Form 3510-2C (8-90) Page 1 of 4 CONTINUE ON REVERSE