June 30, 2017
Lee Simaan
PO Box 549
Summerfield, NC 27358-0549
Subject: Compliance Evaluation Inspection Report
NPDES Permit NCO059251
Quail Acres Mobile Home Park, Rockingham County
Dear Mr. Simaan:
ROY COOPER
Covernor
MICHAEL S. RECAN
kcrotary
S, JAY ZIMMERMAN
fll vdor
On June 27, 2017, Paul DiMatteo of the Division of Water Resources ("Division"), Winston-Salem Regional Office
conducted a Compliance Evaluation Inspection of the above referenced wastewater treatment system. Marc Nault,
Operator in Responsible Charge (ORC), was present for the inspection. An inspection summary follows and an inspection
report is attached for your records.
Site Review
Permit
The current permit became effective on June 1, 2017 and expires on May 31, 2022. Permitted components
include a 15,000 -gallon dosing tank, recirculating surface sand filter and chlorine disinfection. A copy of the
current permit was available for review.
2. Facility Site Review
The facility was as described in the permit. The ORC adjusts valves by hand to achieve recirculation of about
1/3 of the effluent after the sand filter.
Operation and Maintenance
The facility appeared to be well maintained. Mr. Nault reported that the sand in the sand filter was replaced
recently and that the sand is raked weekly. Chlorine tablets for disinfection are kept on site and
dechlorination tablets are kept with the ORC.
4. Effluent/Receiving Waters
The outfall was easily accessible and effluent appeared clear with no noted impact to the receiving stream.
Flow Measurement
The permit requires continuous flow monitoring at the influent or effluent. Mr. Nault reported that flow is
estimated by taking readings from the community water supply's meter and subtracting 9000 gallons per
day to account for the fact that roughly 30 residences are connected to the water system but not the sewer
system. The meters on the well pumps are not regularly calibrated.
State of North Carolina I Environmental Quality I Water Resources
450 West Hnnes Nkll Rnad. ,Suite 300. Wrnatnn-Salem_ NC 27105
"Influent" is defined in 15A NCAC 02B.0503(16) to mean "the wastewater entering a water pollution control
facility." Further, "water pollution control facility" is defined to mean "treatment works", or, "any plant,
septic tank disposal field, lagoon, pumping station, constructed drainage ditch or surface water intercepting_
ditch, incinerator, area devoted to sanitary landfill, or other works not specifically mentioned herein,
installed for the purpose of treating, equalizing, neutralizing, stabilizing, or disposing of waste" (GS 143-
213(17)).
Based on the above, please be advised that your current method of flow measurement does not comply
with the requirement for continuous flow measurement. Note also that Part II, Section D.3 requires approval
of the flow measurement device and monitoring location prior to installation, and that the definition of flow
measurement can be found in Part 11, Section A.
Documentation Review
6. Records/Reports
Discharge Monitoring Reports (DMRs) and lab data are maintained according to the permit. DMRs include all
permit parameters. Copies of DMRs, operator visitation logs, lab reports and Chain -of -Custody forms were
available for review during the inspection.
7. Self -Monitoring Program
A review of DMRs from January, 2015 to April, 2017 revealed no violations.
8. Laboratory
All parameters are analyzed by Meritech, Inc. DMRs were compared with lab documents and no errors or
concerns were noted.
9. Sludge Handling Disposal
Mr. Nault reported that you arrange for pumping of the septic tanks throughout the community and
maintain those records. Records were not available during the inspection.
Required Action - To prevent further action by this Division, within 30 days of receiving this report, please reply in
writing with a timeline for installing a continuous flow measurement device that will comply with permit conditions.
If you should have any questions regarding this report, please do not hesitate to contact Paul DiMatteo at (336)
776-9691 or our office at (336) 776-9800.
Sincerely,
-F',VSherri V. Knight, P.E., Regional Supervisor
Water Quality Regional Operations Section
Winston-Salem Regional Office
Division of Water Resources, NCDEQ
Enclosures — Inspection Report and Summary
CC: WQS Winston-Salem Regional Office - Enforcement File
NPDES Compliance/Enforcement Unit - Enforcement File
Central Files
State of North Carolina I Environmental Quality I Water Resources
450 West Hanes Mill Road, Suite 300, Winston-Salem, NC 27105
United States Environmental Protection Agency
Form Approved
EPA Washington, D C 20460
OMB No 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A National Data System Coding (i e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type
Inspector Fac Type
1 IN 2 15 1 3 I NC0059251 11 12 17/06/27 17 18 l, l
19 I c I 20 LJ
211111 1 1 1 1 1 1 II l 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 l 1 1 1 1 1
I II I I 1 1 116
Inspection Work Days Facility Self-Monitoring Evaluation Rating " B1 QA
Reserved--
72 L,J 73 LLJ74 751 I I I I 80
71 itJ
67 70 [__j
Section B Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES Dermit Number)
10 OOAM 17/06/27
17/06/01
Quail Acres Mobile Home Park
Rt 2 Box 395
Exit Time/Date
Permit Expiration Date
Stokesdale NC 27357
11 OOAM 17/06/27
22/05/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
///
Marc W Nault/ORC/336-342-4748/
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Lee Slmaan,PO Box 549 Summerfield NC 273580549//336-274-2208/
No
Section C Areas Evaluated During Inspection (Check only those areas evaluated)
Permit N Flow Measurement Operations & Maintenance Records/Reports
Self-Monitoring Program N Facility Site Review Effluent/Receiving Waters Laboratory
Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers
Date
Paul DlMatteo` WSRO WQ//336-776-9691/
615i>
lo"ik
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers
Date
7
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete
Page#
NPDES yr/mo/day Inspection Type (Cont.)
31 Nco059251 I11 1217los/27 1 ' 18 1 c I
Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Site Review
1. Permit
The current permit became effective on June 1, 2D17 and expires on May 31, 2022. Permitted
components include a 15,000 -gallon dosing tank, recirculating surface sand filter and chlorine
disinfection. A copy of the current permit was avF-ilable for review
2. Facility Site Review
The facility was as described in the permit. The ORC adjusts valves by hand to achieve recirculation of
about 1/3 of the effluent after the sand filter.
3. Operation and Maintenance
The facility appeared to be well maintained. Mr. Nault reported that the sand in the sand filter was
replaced recently and that the sand is raked weekly. Chlorine tablets for disinfection are kept on site
and dechlorination tablets are kept with the OR'C.
4. Effluent/Receiving Waters
The outfall was easily accessible and effluent appeared clear with no noted impact to the receiving
stream.
5. Flow Measurement
The permit requires continuous flow monitoring at the influent or effluent. Mr. Nault reported that flow is
estimated by taking readings from the community water supply's meter and subtracting 9000 gallons
per day to account for the fact that roughly 30 residences are connected to the water system but not
the sewer system. The meters on the well pumps are not regularly calibrated.
"Influent" is defined in 15A NCAC 02B .0503(16) to mean "the wastewater entering a water pollution
control facility." Further, "water pollution control facility" is defined to mean "treatment works", or, "any
plant, septic tank disposal field, lagoon, pumping station, constructed drainage ditch or surface water
intercepting ditch, incinerator, area devoted to sanitary landfill, or other works not specifically mentioned
herein, installed for the purpose of treating, equalizing, neutralizing, stabilizing, or disposing of waste"
(GS 143-213(17)).
Based on the above, please be advised that your current method of flow measurement does not
comply with the requirement for continuous flow measurement. Note also that Part Il, Section D.3
requires approval of the flow measurement device and monitoring location prior to installation, and that
the definition of flow measurement can be found in Part II, Section A.
Documentation Review
6. Records/Reports
Discharge Monitoring Reports (DMRs) and lab data are maintained according to the permit. DMRs
include all permit parameters Copies of DMRs, operator visitation logs, lab reports and
Chain -of -Custody forms were available for review during the Inspection.
7. Self -Monitoring Program
A review of DMRs from January, 2015 to April, 2017 revealed no violations.
8. Laboratory
All parameters are analyzed by Meritech, Inc DMRs were compared with lab documents and no errors
Page#
Permit: NCO059251
Inspection Date: 06/27/2017
or concerns were noted.
Owner - Facility. Quail Acres Mobile Home Park
Inspection Type Compliance Evaluation
9. Sludge Handling Disposal
Mr. Nault reported that you arrange for pumping of the septic tanks throughout the community and
maintain those records. Records were not available during the Inspection.
Required Action - To prevent further action by this Division, within 30 days of receiving this report,
please reply in writing with a timeline for installing a continuous flow measurement device that will
comply with permit conditions.
Page#
Permit NCO059251 Owner - Facility, Quad Acres Mobile Home Park
Inspection Date. 06/27/2017 Inspection Type- Compliance Evaluation
Operations $ Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment.
Permit
Yes No NA NE
(If the present permit expires In 6 months or less) Has the permittee submitted a new
❑
❑
0
❑
application?
N
❑
❑
❑
Is the facility as described in the permit?
M
❑
❑
❑
# Are there any special conditions for the permit?
❑
E
❑
❑
Is access to the plant site restricted to the general public?
E
❑
❑
❑
Is the inspector granted access to all areas for inspection?
E
❑
❑
❑
Comment. Current permit became effective on June 1. 2017 and expires on May 31, 2022
Record Keeping
Yes No NA NE
Are records kept and maintained as required by the permit?
N
❑
❑
❑
Is all required Information readily available, complete and current?
N
❑
❑
❑
Are all records maintained for 3 years (lab reg required 5 years)?
0
❑
❑
❑
Are analytical results consistent with data reported on DMRs?
N
❑
❑
❑
Is the chain -of -custody complete?
E
❑
❑
❑
Dates, times and location of sampling
E
Name of Individual performing the sampling
E
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete- do they Include all permit parameters?
0
❑
❑
❑
Has the facility submitted its annual compliance report to users and DWQ?
❑
❑
0
❑
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator
❑
❑
E
❑
on each shift?
Is the ORC visitation log available and current?
0
❑
❑
❑
Is the ORC certified at grade equal to or higher than the facility classification?
0
❑
❑
❑
Is the backup operator certified at one grade less or greater than the facility Classification?
0
❑
❑
❑
Is a copy of the current NPDES permit available on site?
N
❑
❑
❑
Page# 4
Permit. NCO069251 Owner - Facility. Quail Acres Mobile Home Park
Inspection Date. 06/27/2017 Inspection Type: Compliance Evaluation
Record Keeping Yes No NA NE
Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 ❑
Comment- Compared DMR data from 2/2017,1/2017 and 12/2016.
Effluent Pipe
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Comment:
Flow Measurement - Influent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Yes No NA NE
■
❑
❑
❑
■
❑
❑
❑
❑
❑
■
❑
Yes No NA NE
❑ ■ ❑ ❑
❑ ■ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ■ ❑
Comment Flow Is estimated based on recordings from the community's water supply. Mr. Nault stated
that about 30 homes were on the water supply but not connected to the sewer system. The
water supply's meter is not regularly calibrated. The permit requires "continuous"
measurements at the "influent or effluent."
Septic Tank
Yes No NA NE
(If pumps are used) Is an audible and visual alarm operational?
❑
❑
0
❑
Is septic tank pumped on a schedule?
N
❑
❑
❑
Are pumps or syphons operating properly?
❑
❑
E
❑
Are high and low water alarms operating properly?
❑
❑
110
❑
Comment- Mr. Nault stated the tanks are pumped by the owner yearly. Records are kept with the
owner
Sand Filters (Low rate)
Yes No NA NE
(If pumps are used) Is an audible and visible alarm Present and operational?
0
❑
❑
❑
Is the distribution box level and watertight?
0
❑
❑
❑
Is sand filter free of ponding?
0
❑
❑
❑
Is the sand filter effluent re -circulated at a valid ratio?
0
❑
❑
❑
# Is the sand filter surface free of algae or excessive vegetation?
N
❑
❑
❑
# Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1)
❑
❑
❑
0
Comment:
Page# 5
Permit: NCO059251
Owner - Facility Quad Acres Mobile Home Park
Type of system ?
Tablet
Inspection Date- 06/2712017
Inspection Type Compliance Evaluation
Is the feed ratio proportional to chlorine amount 0 to 1)?
0
❑
Sand Filters (Low rate)
Yes No NA NE
Disinfection -Tablet
Yes No NA NE
Are tablet chlorinators operational?
0
❑
❑
❑
Are the tablets the proper size and type?
0
❑
❑
❑
Number of tubes in use?
3
❑
Is the level of chlorine residual acceptable?
❑
❑
❑
E
Is the contact chamber free of growth, or sludge buildup?
N
❑
❑
❑
Is there chlorine residual prior to de -chlorination?
❑
❑
130
Comment.
De -chlorination
Yes No NA NE
Type of system ?
Tablet
Is the feed ratio proportional to chlorine amount 0 to 1)?
0
❑
❑
❑
Is storage appropriate for cylinders?
E
❑
❑
❑
# Is de -chlorination substance stored away from chlorine containers?
0
❑
❑
❑
Are the tablets the proper size and type?
0
❑
❑
❑
Comment: Dechlorination tablets are kept with the ORC.
Are tablet de -chlorinators operational? 0 ❑ ❑ ❑
Number of tubes in use? 2
Comment.
Page# 6