Loading...
HomeMy WebLinkAboutNC0089435_Site Visit_20170707N,Division State of North Carolina of Water Resources " Water Quality Regional Operations Section Environmental Staff Report Quality To: ® NPDES Unit ❑ Non -Discharge Application No.: NCO089435 Attn: Derek Denard Facility name: Martin County WTP From: Scott Vinson Washington Regional Office Note- This form has been adapted from the non -discharge f�ty staff report to document the review of both non - discharge and NPDES permit applications and/or renewals Please complete all sections as they are applicable I. GENERAL AND SITE VISIT INFORMATION 1. Was a site visit conducted? ® Yes or ❑ No a Date of site visit: 6/22/2017 RECEIVEMCDENWR b. Site visit conducted by: Robbie Bullock & Scott Vinson JUL O c. Inspection report attached9 ® Yes or F-1No2��% d. Person contacted: Joe Thaxton, ORC and their contact information: 252 - 43 Water Quality (—) 789 --�J@rt#ir►g-Section e. Driving directions: Located off Hwy. 17 in Williamston, Martin County. Turn east off 17 onto Park Street and site is at the end located behind the local Roses shopping center 2 Discharge Point(s): Latitude. 3.58481 Longitude -77.0442 3. Receiving stream or affected surface waters: UT to Sweetwater Creek Classification: C River Basin and Subbasin No.- Roanoke River, 03-02-09 Describe receiving stream features and pertinent downstream uses: Index No.- 23-50, This receiving stream/unnamed tributary is classified and is used for or has the potential to be used for secondary recreation, fishing, wildlife, fish consumption, aquatic life including propagation, survival and maintenance of biological integrity, and agriculture. Although the stream is primarily surrounded by woods and wetlands from the discharge point until it joins (approximately 3 25 miles) with the Roanoke River, it has the potential for wading, boating and other uses involving human body contact with water in an infrequent, unorganized, or incidental manner. II. PROPOSED FACILITIES: NEW APPLICATIONS - n/a III. EXISTING FACILITIES: MODIFICATION AND RENEWAL APPLICATIONS 1 Are there appropriately certified Operators in Charge (ORCs) for the facility? ❑ Yes ® No ❑ N/A ORC- Joe Thaxton Certificate #. PC -2/ 1001711 Backup ORC: Certificate #: • The facility has a current staff member Eddie Bristow, ready to sit for the September 14 2017 certification exam. If the employee does not pass the ORC was directed to acquire a certified backup operator immediately. (see attached inspection report) FORM: WQROSSR 04-14 Page 1 of 3 2. Are the design, maintenance and operation of the treatment facilities adequate for the type of waste and disposal system? ® Yes or ❑ No If no, please explain: Description of existing facilities: A conventional water treatment plant generating filter -backwash wastewater and sludge potentially containing the treatment additives: Alum/ aluminum sulfate, sodium permanganate, powdered activated carbon, sodium hydroxide, polymer, chlorine, AND Phosphoric acid (as a corrosion inhibitor for potable water lines) which has been used since startup of March 2016 and apparently was not included by engineer in original application process AND a new additive Copper Sulfate proposed to start using in July 2017 (it has Oust been approved by DWR-Public Water) for help with controlling algae in the holding basin where water is pumped from the river to the plant overnight to be treated next day. Proposed flow: 0.7 MGD Current permitted flow: n/a Explain anything observed during the site visit that needs to be addressed by the permit, or that may be important for the permit writer to know (i.e., equipment condition, function, maintenance, a change in facility ownership, etc.) 3. Are the site conditions (e.g., soils, topography, depth to water table, etc) maintained appropriately and adequately assimilating the waste? ® Yes or ❑ No If no, please explain: 4. Has the site changed in any way that may affect the permit (e.g., drainage added, new wells inside the compliance boundary, new development, etc.)? ❑ Yes or ® No If yes, please explain: 5. Is the residuals management plan adequate? ® Yes or ❑ No If no, please explain: 6. Are the existing application rates (e.g., hydraulic, nutrient) still acceptable? ❑ Yes or ❑ No ® N/A If no, please explain: 7 Is the existing groundwater monitoring program adequate? ❑ Yes ❑ No ® N/A If no, explain and recommend any changes to the groundwater monitoring program. 8. Are there any setback conflicts for existing treatment, storage and disposal sites? ❑ Yes or ® No If yes, attach a map showing conflict areas. 9. Is the description of the facilities as written in the existing permit correct? ❑ Yes or ® No If no, please explain: The "treatment additives" list on page 2 of 6 need to include Phosphoric acid & Copper Sulfate. 10. Were monitoring wells properly constructed and located9 ❑ Yes ❑ No ® N/A If no, please explain: 11. Are the monitoring well coordinates correct in BIMS? ❑ Yes ❑ No ® N/A If no, please complete the following (expand table if necessary). 12. Has a review of all self-monitoring data been conducted (e.g., DMR, NDMR, NDAR, GW)? ® Yes or ❑ No Please summarize any findings resulting from this review: No current problems. There was a NOD dated 3/5/15 for failure to submit eDMRs and a NOV (NOV-2015-PC-0211) dated 8/20/15 for failure to submit eDMRs The plant did not start start up testing until November 2015 and full time production until March of 2016 Provide input to help the permit writer evaluate any requests for reduced monitoring, if applicable. 13. Are there any permit changes needed in order to address ongoing BIMS violations? ❑ Yes or ® No If yes, please explain: 14. Check all that apply: ® No compliance issues ❑ Notice(s) of violation ❑ Current enforcement action(s) ❑ Currently under JOC ❑ Currently under SOC ❑ Currently under moratorium FORM. WQROSSR 04-14 Page 2 of 3 Please explain and attach any documents that may help clarify answer/comments (i.e., NOV, NOD, etc.) If the facility has had compliance problems during the permit cycle, please explain the status. Has the RO been working with the Permittee? A backup ORC does need to be named soon. Is a solution underway or in place? Yes, an employee is going to sit for his PC certification the next testing date September 14, 2017. Have all compliance dates/conditions in the existing permit been satisfied? ® Yes ❑ No ❑ N/A If no, please explain: 15. Are there any issues related to compliance/enforcement that should be resolved before issuing this permit? ❑ Yes ®No❑N/A If yes, please explain: 16. Possible toxic impacts to surface waters: None that WaRO is aware of. 17. Pretreatment Program (POTWs only): n/a IV. REGIONAL OFFICE RECOMMENDATIONS 1. Do you foresee any problems with issuance/renewal of this permit? ❑ Yes or ® No If yes, please explain: 2. List any items that you would like the NPDES Unit or Non -Discharge Unit Central Office to obtain through an additional information request: None. 3. List specific permit conditions recommended to be removed from the permit when issued: None. 4. List specific special conditions or compliance schedules recommended to be included in the permit when issued - Condition Reason A conventional water treatment plant generating filter -backwash wastewater and sludge potentially containing the treatment additives: Alum/ aluminum sulfate, sodium permanganate, powdered activated carbon, sodium hydroxide, polymer, chlorine, AND Phosphoric acid (as a corrosion inhibitor for Site Description Update potable water lines which has been used since startup of March 2016 and apparently was not included by engineer in original application process) AND a new additive Copper Sulfate (proposed to start using in July 2017, which has just been approved by DWR-Public Water, for help with controlling algae in the holding basin where water is pumped from the river to the plant overnight to be treated next day). 5. Recommendation: ❑ Hold, pending receipt and review of additional information by regional office ® Hold, pending review of draft permit by regional office ❑ Issue upon receipt of needed additional information ❑ Issue ❑ Deny (Please state reasons: ) 6. Signature of report preparer: — Signature of regional supervisor: Date: &-20,/7- V. -20`/7 V. ADDITIONAL REGIONAL STAFF REVIEW ITEMS None. FORM- WQROSSR 04-14 Page 3 of 3 United States Environmental Protection Agency Fofm Approved EPA Washington, D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A National Data System Coding (I e , PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I NCO089435 I11 121 17/06/22 I17 18 LCI 19 L G j 201 I 21111111 1111111 II II 1111111 1111111 1111111 II I I �6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ------------Reserved 67 70 71 I I 72 n, � L 73 I I 174 751 III I I I 180 LJ I I L_LJ Section 8 Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09 30AM 17/06/22 14/04/01 Martin County WTP 1001 Park St Exit Time/Date Permit Expiration Date Williamston NC 27892 11 15AM 17/06/22 17/05/31 Name(s) of Onsite Representabve(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Joseph R Thaxton/ORC// Name, Address of Responsible Officiairritle/Phone and Fax Number Contacted David Bone,PO Box 668 Williamston NC 278920668//252-789-4300/2527894309 No Section C Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Operations & Maintenance Records/Reports 0 Self -Monitoring Program Sludge Handling Disposal 0 Facility Site Review Effluent/Receiving Waters E Laboratory Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Scott A Vinson WARD WQ//252-946-6481 Ext 208/ Robert E Bullock WARO WQ//252-948-3924/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete Page# NPDES yr/mo/day Inspection Type 31 NCo089435 111 121 17/06/22 117 18 ICI Section D Summary of Find ing/Commerts (Attach additional sheets of narrative and checklists as necessary) The review period for this Inspection was November 2015 through April 2017 No violations were noted over the review period A renewal application has been submitted The current permit which Is set to expire on May 31, 2017 will remain effective until a new permit is issued Joe Thaxton is the ORC with no backup ORC for the facility The permittee has 120 days to fill the vacancy of the backup ORC The facility is considered to be Compliant with NPDES permit NC0089435 Page# Permit NCO089435 Inspection Date 06/22/2017 Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Owner -Facility Martin County WTP Inspection Type Compliance Evaluation Does the facility analyze process control parameters, for ex MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment Permit (If the present permit expires in 6 months or less) Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ ❑ ❑ E ❑ Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ M ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Comment A renewal application has been submitted The current permit which is set to expire on May 31, 2017 will remain effective until a new permit is issued Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ❑ ❑ ❑ ❑ Is all required information readily available, complete and current? ❑ ❑ ❑ ❑ Are all records maintained for 3 years (lab reg required 5 years)? M ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? ❑ 0 ❑ ❑ Dates, times and location of sampling 0 Name of individual performing the sampling ❑ Results of analysis and calibration Dates of analysis Name of person performing analyses Transported CDCs Are DMRs complete do they include all permit parameters? E ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ 0 ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ M ❑ on each shift? Is the ORC visitation log available and current? ❑ 0 ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? M ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? ❑ M ❑ ❑ Is a copy of the current NPDES permit available on site? M ❑ ❑ ❑ Page# 3 Permit NCO089435 Inspection Date 06/22/2017 Record Keeping Facility has copy of previous year's Annual Repot on file for review? Owner - Facility Martin County WrP Inspection Type Compliance Evaluation Yes No NA NE ❑ ❑ N ❑ Comment Joe Thaxton Is the ORC with nc backup ORC for the facility The permittee has 120 days to fill the vacancy of the backup ORC Printed name of Individual sampling and sample type needs to be filled out on the sampling chain of custody Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? 0 ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? E ❑ ❑ ❑ # Is the facility using a contract lab? E ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6 0 degrees E ❑ ❑ ❑ Celsius)? Incubator (Fecal Coliform) set to 44 5 degrees Celsius+/- 0 2 degrees? Incubator (BOD) set to 20 0 degrees Celsius +/- 1 0 degrees? ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ Comment The WTP Is field parameter certified for Total Residual Chlorine and PH All other samples are sent to Environment 1 for analysis Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately % of the sidewall depth) Comment The "secondary clarifier" is a settling basin for solids to settle before discharge Granville Farms land applies solids unser permit WQ0035595 Pump Station - Effluent Is the pump wet well free of bypass Imes or structures? Yes No NA NE ■ ❑ ❑ ❑ ❑ ❑ N ❑ ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ N ❑ ❑ ❑ ❑ ❑ ■ ❑ E ❑ ❑ ❑ ❑ ❑ N ❑ ❑ ❑ N ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ Page# 4 Permit NCO089435 Owner -Facility Martin County WTP Is composite sampling flow proportional? ❑ ❑ Inspection Date 06/22/2017 Inspection Type Compliance Evaluation Is sample collected below all treatment units? M ❑ Pump Station - Effluent Yes No NA NE Are all pumps present? 0 ❑ ❑ ❑ Are all pumps operable? M ❑ ❑ ❑ Are float controls operable? M ❑ ❑ ❑ Is SCADA telemetry available and operational? 0 ❑ ❑ ❑ Is audible and visual alarm available and operational? ❑ ❑ ❑ N Comment Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ M ❑ Is sample collected below all treatment units? M ❑ ❑ ❑ Is proper volume collected? N ❑ ❑ ❑ Is the tubing clean? ❑ ❑ 0 ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6 0 degrees M ❑ ❑ ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type 0 ❑ ❑ ❑ representative)? Comment Samples are grab as stated In the NPDES permit Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? M ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? M ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ N ❑ Comment Page# 5