HomeMy WebLinkAbout20070191 Ver 3_More Info Received_20170517Homewood, Sue
From:
Sent:
To:
Cc:
Subject:
Attachments:
Sue
Paul Petitgout <ppetitgout@gmail.com>
Wednesday, May 17, 2017 10:27 AM
Homewood, Sue; Johnson, Alan
Shaeffer, David L SAW
2007-0191 v3 Bryton - Final Culvert Baffle Detail
Revised Bryton Culvert Baffle Detail.pdf
Attached, please find the revised Culvert Baffle Detail that we discussed on Friday, May 12, 2017. As you may
remember, we discussed adding two additional baffles spaced evenly between the upstream and downstream inverts of
the pipe (total of 4 baffles). Other than adding the additional two baffles, these revised details are the same as the
previous version. Please let me know if you have any questions or need any additional information.
Thanks!!
Paul
ADWMS
ENVIRRNMENTRL INR ECRLRCICIL SERVICES
S. Paul Petitgout
President/Managing Member
Lowrys Environmental & Ecological Services, LLC
1823 Quinn Road
Chester, South Carolina 297o6
Phone: (803) 992-0910
Email: ppetitgoutCa)gmail.com
130'
m
° .
a. ^ g
FLOW 12' ° FLOW
43'
— 4"- 6" WIDE CONCRETE WEIR/BAFFLE (TYP.)
BOX CULVERT TOP VIEW
130'
STREAM BED
(1' CULVERT BURY)
1 FILL MATERIAL TO BE PLACED @
1 DEPTH BETWEEN BAFFLES
FLOW 10' 4"- 6" WIDE CONCRETE FLOW
I WEIR/BAFFLE
BOX CULVERT SIDE VIEW
*EXCAVATED STREAM BED MATERIAL TO BE USED AS FILL FOR CULVERT BURY
CULVERT CONCRETE WEIR/BAFFLE DETAIL
TYPICAL DETAIL - N.T.S.
PAGE 1 of 2
HuntersvBer toNortCarolina / '� R. Joe Harris & Associates, Inc.
Engineering • Planning • Management
Drawn B . DBG Date: 05-03-201 Rev./;
127 6cn C:iscy Drivc Suitc 101. Port Mill, S.C. 29708 (803) 802-1799 Fax (803) 502-0886
12'
4" - 6" '. BOX CULVERT
�..................................................................
°'` • RETAINING WALL
CONCRETE
° WEIR/BAFFLE
BOX CULVERT TOP SECTION VIEW
'I CONCRETE
WEIR/BAFFLE
I— — 4
4"
12"
e. BOX CULVERT
12'
STEEL REBAR PIN (TYP)
T O.C. OR AS RECOMMENDED
BY MANUFACTURER
BOX CULVERT FRONT SECTION VIEW
CULVERT CONCRETE WEIR/BAFFLE DETAIL
TYPICAL DETAIL - N.T.S.
Bryton
Huntersville, North Carolina
PAGE 2 of 2
R. Joe Harris & Associates, Inc.
Engineering • Planning • Management
127 Ban Casey Drive Suit, 101, Furl Mill, S.C. 29708 (803) sot -1799 Fax: (803) 802-0886