Loading...
HomeMy WebLinkAboutNC0022691_Compliance Evaluation Inspection_2017062011 Water kesources ENVIRONMENTAL QUALITY June 20, 2017 Mr. Andrew Luter Yes AF Utilities Exp, LLC 1900 16th Street, Suite 950 Denver, CO 80202 SUBJECT: Compliance Evaluation Inspection Autumn Forest AMC WWTP NPDES Permit No. NCO022691 Guilford County Dear Mr. Luter: ROY COOPER Governor MICHAEL S. REGAN Secretary S. JAY ZIMMERMAN Director RECEIVED/NCDEWWR JUN 2 3 2017 Water Quality Permitting Section On June 07, 2017, Min Xiao and George Smith of this office met with Tony Montero, Randy Bell from Bell Enterprises, and Annie Haluska of Apex Companies to perform a Compliance Evaluation Inspection on the wastewater treatment system serving the Autumn Forest MHC. The inspection findings are detailed below and an inspection checklist is attached. I. Permit The current permit became effective October 1, 2016, and will expire at midnight on June 30, 2021. A current copy of the permit was kept onsite. H. Self -Monitoring Program The monthly DMRs were reviewed for the period of January 2016 through December 2016. The Autumn Forest facility violated effluent permit limits in April, May, June, July, September, October, and December. These violations have already been addressed in separate correspondence by this office. M. Flow Measurement The NPDES permit requires continuous flow recording and an annual calibration of the flow measuring device. Effluent flow is obtained using a Siemens HydroRanger 200 meter. The meter was last calibrated by Carolina Technical Services Specialists on June 06, 2017. Currently, the auto -sampler is collecting constant time/constant volume composite samples. Efforts are being made to reprogram the sampler to collect flow proportional composite samples. IV. Sludge Handling and Disposal Solids are removed from the single digester as needed by Jenkins Waste Management for disposal in the City of Greensboro POTW. V. Operations and Maintenance Only one side of the dual train system (aeration basin, clarifier and chlorinator) is being used due to the low influent flow volume. Since September 2016, Autumn Forest WWTP has changed the operators. The current operators have made efforts to operate and maintain the plant. VI. Facility Site Review On February 10, 2017, the Division granted an Authorization to Construct to Autumn Forest WWTP for installation of a new drum -based chemical feed system (aluminum chloride). The system installation has been completed before and has been in service for total phosphorus reduction. State of North Carolina I Environmental Quality I Water Resources 450 West Hanes Mill Road, Suite 300, Winston-Salem, NC 27105 Phone: 336-776-98001 Internet: www.ncdenr gov The 0.082 MGD permitted system consists of the following: EQ basin, bar screen, flow splitter, dual aeration basins, clarifiers and chlorinators followed by a single dechlorinator unit, flow meter and sludge holding. Only one side of the dual train system (aeration basin, clarifier and chlorinator) is being used due to the low influent flow volume VII. Records/Reports A review of the facility files indicates thGt all records are being maintained according to the permit. The ORC performs on-site measurements for flow, TRC, temperature, dissolved oxygen and pH. Other parameters are measured by Statesville Analytical laboratory. A comparison of the January 2017 DMR with the corresponding laboratory data found that the values were transcribed onto the monitoring report correctly, except for the DO concentration for effluent. The DMR of January, February, and March will be amended and resubmitted. VIII. Upstream/Downstream Sampling The upstream samples are collected from a lake, and the downstream sampling location is more than 100 feet. During the inspection, it was noted that the upstream sampling was not relevant and representative due to its location. The permittee can request a minor permit modification to get the upstream monitoring requirement removed. However, the downstream still needs to be monitored. The staff of this office brought a meter to measure some parameters at the effluent discharge point and the downstream sampling location. The data are shown below. ampling location Parameter Effluent discharge point Downstream Temperature (°C) 22.10 2380 DO (mg/1) 6.87 4.82 DO Saturation (%) 80.30 5860 pH 7.17 7.99 Conductivity (uS/cm) 839.00 143.80 IX. Effluent/Receiving Waters The system discharges into a tributary of Reedy Fork, class "WS -V; NSW" waters in the Cape Fear River Basin. The effluent was observed to be clear on the day of the inspection. Should you have any questions concerning this report, please contact Min Xiao or me at (336) 776-9800. Sincerely, herri V. Knight, PE Regional Supervisor Water Quality Regional Operations Section Division of Water Resources cc* Annie Haluska (ahaluska@apexcos.com) Central Files NPDES Unit WSRO United States Environmental Protection Agency Fort Approved EPA Washington, D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A National Data System Coding (i e, PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 U 2 15 I 3 I NCO022691 I11 12 17/06/07 17 18 i C i 19 I G i 20I 211 1 1 1 1 1 1 1 1 1 11 1 1 1 I I I I I I l i i l l 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 _f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved-- -- 73 I 4 75 1 1 1 1 1 80 72 L�j 67 70l_l 71 I —1 Section B Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 12 20PM 17/06/07 16/10/01 Autumn Forest MHC WWTP 3700 Autumn Forest Dr Exit Time/Date Permit Expiration Date Browns Summit NC 27214 01 30PM 17/06/07 21/06/30 Name(s) of Onsite Representative(s)lfitles(s)/Phone and Fax Number(s) Other Facility Data /// Anthony Oscar Montero/ORC/336433-7221/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Adam Motsinger,136 Fairview Rd Ste 125 Mooresville NC 28117//704-799-6390/ No Section C Areas Evaluated During Inspection (Check only those areas evaluated) Permit E Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program N Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Min Xiao WSRO WQ//336769800/ M \ 0/��� Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date 6%�%�' EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete Page# NPDES yr/mo/day Inspection Type 31 NCO022691 I11 12 17/06/07 17 18 ICI Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# Permit. NCO022691 Owner -Facility. Autumn Forest MHC WWTP Inspection Date 06/07/2017 Inspection Type Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less) Has the permittee submitted a new ❑ ❑ 0 ❑ application? Is the facility as described in the permit? M ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? M ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment The current permit became effective October 1, 2016, and will expire at midnight on June 30, 2021 A current copy of the permit was kept onsite Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? M ❑ ❑ ❑ Does the facility analyze process control parameters, for ex MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment Only one side of the dual train system (aeration basin, clarifier and chlorinator) is being used due to the low influent flow volume Since September 2016, Autumn Forest WWTP has 0 ❑ changed the operators The current operators have made efforts to operate and maintain ❑ Has the facility submitted its annual compliance report to users and DWQ? the plant ❑ M ❑ (if the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator Record Keeping Yes No NA NE Are records kept and maintained as required by the permit?- 0 ❑ ❑ ❑ Is all required information readily available, complete and current? 0 ❑ ❑ ❑ Are all records maintained for 3 years (lab reg required 5 years)? M ❑ ❑ ❑ Are analytical results consistent with data reported on DM Rs? ❑ ❑ ❑ Is the chain -of -custody complete? ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported CDCs 0 Are DMRs complete do they Include all permit parameters? 0 ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ M ❑ (if the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ M ❑ on each shift? Is the ORC visitation log available and current? M ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? 0 ❑ ❑ ❑ Page# 3 "v Permit NCO022691 Owner - Facility Autumn Forest MHC yWUrP Inspection Date. 06/07/2017 Inspection Type- Compliance Evaluation Record Keeping Yes No NA NE Is the backup operator certified at one grade less or greater than the facility classification? M ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? E ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ N ❑ Comment: A comparison of the January 2017 DMR with the corresoonding laboratory data found that the values were transcribed onto the monitoring report correctly, except for the DO concentration for effluent The DMR of January. February. and March will be amended and resubmitted Bar Screens Yes No NA NE Type of bar screen 0 ❑ ❑ ❑ a Manual 0 ❑ ❑ ❑ b Mechanical ❑ ❑ ❑ ❑ Are the bars adequately screening debris? E ❑ ❑ ❑ Is the screen free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screening in compliance? N ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment A milk crate hangs below the influent pipe of the EQ basin to catch trash and rags Equalization Basins Yes No NA NE Is the basin aerated? 0 ❑ ❑ ❑ Is the basin free of bypass lines or structures to tie natural environment? 0 ❑ ❑ ❑ Is the basin free of excessive grease? 0 ❑ ❑ ❑ Are all pumps present? 0 ❑ ❑ ❑ Are all pumps operable? N ❑ ❑ ❑ Are float controls operable? ❑ ❑ ❑ N Are audible and visual alarms operable? ❑ ❑ ❑ 0 # Is basin size/volume adequate? 0 ❑ ❑ ❑ Comment The EQ basin has 2 pumps It's aerated using a single blower Chemical Feed Yes No NA NE Is containment adequate? E ❑ ❑ ❑ Is storage adequate? 0 ❑ ❑ ❑ Are backup pumps available? 0 ❑ ❑ ❑ Is the site free of excessive leaking? 0 ❑ ❑ ❑ Page# 4 t* Permit. NCO022691 Owner - Facility Autumn Forest MHC WWTP Inspection Date- 06/07/2017 Inspection Type- Compliance Evaluation Chemical Feed Yes No NA NE Comment- The aluminum chloride is added before entering the secondary clarifier Aeration Basins Mode of operation Type of aeration system Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Is the DO level acceptable?(1 0 to 3 0 mg/1) Yes No NA NE Ext Air Diffused ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ N ❑ ❑ ❑ ■ ❑ ❑ ❑ N ❑ 1:11:1 ❑ ❑ ❑ E ❑ ❑ 110 Comment Only one side of the dual train system (aeration basin, clarifier and chlorinator) is being used due to the low influent flow volume Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? ❑ ❑ 0 ❑ Are weirs level? N ❑ ❑ ❑ Is the site free of weir blockage? N ❑ ❑ ❑ Is the site free of evidence of short-circuiting? N ❑ ❑ ❑ Is scum removal adequate? 0 ❑ ❑ ❑ Is the site free of excessive floating sludge? 0 ❑ ❑ ❑ Is the drive unit operational? ❑ ❑ 0 ❑ Is the return rate acceptable (low turbulence)? 0 ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? 0 ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) ❑ ❑ ❑ 0 Comment, Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? 0 ❑ ❑ ❑ Are the tablets the proper size and type? E ❑ ❑ ❑ Number of tubes In use? 4 Is the level of chlonne residual acceptable? ❑ ❑ ❑ N Page# 5 a Permit NCO022691 Owner - Facility Autumn Forest MHC WWTP Inspection Date- 06/07/2017 Inspection Type. Compliance Evaluation Disinfection -Tablet Yes No NA NE Is the contact chamber free of growth, or sludge buildups M ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑ 0 Comment De -chlorination Yes No NA NE Type of system ? Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ ❑ 0 Is storage appropriate for cylinders? 0 ❑ ❑ ❑ # Is de -chlorination substance stored away from chlorine containers? 0 ❑ ❑ ❑ Comment Are the tablets the proper size and type? 0 ❑ ❑ ❑ Are tablet de-chlonnators operational? ❑ ❑ ❑ Number of tubes in use? Comment Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? M ❑ ❑ ❑ Is the flow meter operational? ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment Effluent flow Is obtained using a Siemens HvdroRanoer 200 meter The meter was last calibrated by Carolina Technical Services Specialists on June 06, 2017 Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? M ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, and M ❑ ❑ ❑ sampling location)? Comment The upstream samples are collected from a lake, and the downstream sampling location Is more than 100 feet Page# 6