HomeMy WebLinkAboutNC0021547_NOV20170368_20170623I 6A W"el�fiof n;M11keN:r�,� �= Certified Mail #7016 1370 00016571 9S29 Return Receipt Requested June 20, 2017 Summer Woodard, Manager Town Town of Franklin PO Box 1479 Franklin, NC 28744-1479 SUBJECT: NOTICE OF VIOLATION Tracking Number: NOV-2017-PC-0368 Permit No. NCO021547 Franklin WWTP Macon County Dear Permittee: ROY COOPER, fro MICHAEL S. REGAN lwadt lr S. JAY ZIMMERMAN ArWor RECENEDINCDECIDWR JUN 2 3 2017 Water 0 Stion Permittingec The North Carolina Division of Water Resources conducted a Compliance Evaluation Inspection of the Franklin WWTP on June 7, 2017. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0021547. A summary of the findings and comments noted during the inspection are provided in the enclosed copy of the inspection report. The Compliance Evaluation inspection was conducted by Division of Water Resources staff from the Asheville Regional Office. The following violation(s) were noted during the inspection: Inspection Area Description of Violation Permit A Bypass of the treatment facility to the ground surface was occurring at the time of the inspection. [NC0021547 Part II. C. 4(c) Prohibition of Bypass; Bypass from the treatment facility is prohibited and the Permit Issuing Authority may take enforcement action against a Permittee.] Corrective Measures: Remedial actions should have already been taken to correct this problem and prevent further occurrences in the future. The Division of Water Resources may pursue enforcement action for this and any additional violations of State law. State of North Carolina I Environmental Quality Water Resources 2090 U S 70 Highway, Swannanoa, NC 28778 828-296-4500 To prevent further action, please respond in writing to this office within 15 days upon your receipt of this Notice of Violation regarding your plans or measures to be taken to address the indicated violations and other identified issues, if applicable. 1 If you should have any questions, please do not hesitate to contact Mikal Willmer with the Water Quality Regional Operations Section in the Asheville Regional Office at 828-296-4500. Sincerely, G. Landon Davidson, P.G.,Regional Supervisor Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS: Inspection Report Cc: Bill Deal, ORC WQS Asheville Regional Office - Enforcement File NPDES Compliance/Enforcement Unit - Enforcement File United States Environmental Protection Agency Form Approved EPA Washington, D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A National Data System Coding (i e , PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 1 3 I N00021547 111 12 17/06/07 17 18 t C I 19 I G I 20L] 21111111 111111111 11111 1111 1111111 11111111111 l66 I Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA -Reserved 67 70 LI I 71 � LJ 1 72 N 73 Lj 751 I I I I I I 180 J Section B Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10 OOAM 17/06!07 12/12101 Franklin WWTP Sierra Dr Exit Time/Date Permit Expiration Date Franklin NC 28734 12 10PM 17/06/07 17/11/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data William Logan Deal/ORC/828-524-2516/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Sam Greenwood,PO Box 1479 Franklin NC 2874414791Town Manager/828-524-2516/ No Section C Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal Pollution Prevention Facility Site Review Effluent/Receiving Waters Other Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Mikal Willmer ARO WQ//B28-296-4686/ _ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date (:L�_� EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete Page# NPDES yr/mo/day Inspection Type (Cont) 1 3I NCO021547 I11 12 17/06/07 17 18 1C1 Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Inspector, Mikal Wlllmer, with the Asheville Regional Office conducted a Compliance Evaluation Inspection of the Franklin WWTP on June 7, 2017 ORC, BIII Deal was present and assisted in the inspection Overall the plant was well maintained and operated, however, the system was determined to be non-compliant with NPDES Permit Standard Conditions At the time of the inspection, a bypass of the treatment system was noted Secondary effluent was/is seeping from a cracked manhole riser upstream of the chlorine contact basin I further discussed the bypass with Mr Deal on 6!8/2017 He informed me the leak had been occurring for several years, but it was never mentioned in an inspection report or listed as a compliance issue Mr Deal also stated plant staff were under the impression this was not classified as a bypass An NOV is being issued with a request to abate the bypass as soon as possible A follow-up inspection will be conducted to verify system compliance once we receive notification a repair is made Please refer to the attached NOV for specific permit condition violations and requested corrective action Page# 2 U ,i Permit NCO021547 Owner - Facility Franklin WWTP Inspection Date- 06/07/2017 Inspection Type Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? M ❑ ❑ ❑ Does the facility analyze process control parameters, for ex MLSS, MCRT, Settleable M ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment Overall the plant is clean and well maintained ORC states they analyze miss, pH, VSS and Alkalinity DO is monitored by in-line DO meters Permit Yes No NA NE (If the present permit expires In 6 months or less) Has the permittee submitted a new 0 ❑ ❑ ❑ application? M ❑ ❑ ❑ Is the facility as described In the permit? M ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? M ❑ ❑ ❑ Are all records maintained for 3 years (lab reg required 5 years)? M ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? 0 ❑ ❑ ❑ Dates, times and location of sampling Name of Individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete do they Include all permit parameters? ❑ ❑ ❑ Has the facility submitted Its annual compliance report to users and DWQ? M ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ 0 ❑ on each shift? Is the ORC visitation log available and current? M ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? 0 ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? 0 ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑ Page# 3 Permit. NCO021547 Inspection Date 06/07/2017 Record Keeping Facility has copy of previous year's Annual Report on file for review? Owner - Facility. Franklin WWTP Inspection Type. Compliance Evaluation Yes No NA NE N ❑ ❑ ❑ Comment All external and Internal testina records are In binders within the laboratory and sorted b year. The ORC also maintains a log of routine maintenance Yes No NA NE # Is composite sampling flow proportional? ❑ N Flow Measurement - Influent Yes No NA NE # Is flow meter used for reporting? ❑ N ❑ ❑ Is flow meter calibrated annually? S ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment An Influent flow meter Is located at headworks ORC states thev are averaaina about 1 MGD coming Into the plant Yes No NA NE # Is composite sampling flow proportional? ❑ N Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment Ultrasonic flow meter is callbratec annually by Clearwater ORC reports, on average, flow Is 800,000 GPD leaving the plant Influent Samplinq Yes No NA NE # Is composite sampling flow proportional? ❑ N ❑ ❑ Is sample collected above side streams? E ❑ ❑ ❑ Is proper volume collected? ❑ ❑ ❑ E Is the tubing clean? ❑ ❑ ❑ E # Is proper temperature set for sample storage (kept at less than or equal to 6 0 degrees ❑ ❑ ❑ Celsius)? Is sampling performed according to the permit? N ❑ ❑ ❑ Comment Facility has a refrigerated Influent sampler. ORC stated during the Inspection he believes the Influent sampler Is set to time composite Grit Removal Type of grit removal a Manual b Mechanical Yes No NA NE Page# 4 1 Permit NCO021547 Owner - Facility Frandn wwTP Type of bar screen N ❑ Inspection Date 06/07/2017 Inspection Type Compliance Evaluation a Manual ❑ ❑ Grit Removal Yes No NA NE Is the grit free of excessive organic matter? N ❑ ❑ ❑ Is the grit free of excessive odor? ® ❑ ❑ ❑ # Is disposal of grit in compliance? 0 ❑ ❑ ❑ Comment Solids are hauled to the landfill from the headworks on Monday and Friday Bar Screens Yes No NA NE Type of bar screen N ❑ ❑ ❑ a Manual ❑ ❑ ❑ ❑ b Mechanical N ❑ ❑ ❑ Are the bars adequately screening debris? 0 ❑ ❑ ❑ Is the screen free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screening in compliance? 0 ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment The bar screen and headworks appeared to be operating effectively at the time of the inspection ORC reports some issues with screen backups when septage haulers unload ORC believes this is due to the septage station being so close to the headworks Equalization Basins Yes No NA NE Is the basin aerated? N ❑ ❑ ❑ Is the basin free of bypass lines or structures to the natural environment? N ❑ ❑ ❑ Is the basin free of excessive grease? N ❑ ❑ ❑ Are all pumps present? ❑ ❑ E ❑ Are all pumps operable? ❑ ❑ N ❑ Are float controls operable? 0 ❑ ❑ ❑ Are audible and visual alarms operable? 0 ❑ ❑ ❑ # Is basin size/volume adequate? N ❑ ❑ ❑ Comment Audio and Visual alarms and SCADA were present and in use at the headworks Alarms are checked regularly by VWVTP staff The 1 5 MGD EQ basin Is aerated and gravity feeds to the WVTrP ORC reports the plant has seen surges to the top of the EQ basin during heavy rain and storm events Oxidation Ditches Yes No NA NE Are the aerators operational? 0 ❑ ❑ ❑ Are the aerators free of excessive solids build up? 0 ❑ ❑ ❑ # Is the foam the proper color for the treatment process? 0 ❑ ❑ ❑ Page# 5 Permit NCO021547 Owner - Facility Inspection Date 06/07/2017 Inspection Type Franklin WWTP Compliance Evaluation Is the clarifier free of black and odorous wastewater? 0 ❑ Oxidation Ditches Yes No NA NE Does the foam cover less than 25% of the basin's surface? 0 ❑ ❑ ❑ Is the DO level acceptable? M ❑ ❑` ❑ Are settleometer results acceptable (> 30 minutes)? ❑ ❑ ❑ N Is the DO level acceptable?(1 0 to 3 0 mg/1) 0 ❑ ❑ ❑ Are settelometer results acceptable?(400 to 800 ml/I In 30 minutes) ❑ ❑ ❑ 0 Comment The oxidation ditch uses floating brush aerators connected to in-line HACH DO meters ORC has the aerators set to turn on when DO drops below 0 5 mg/L. Mr Deal states they aim to keep the DO between 0 5 and 1 mg/L. The plant is also in the process of upgrading the drives on the aerators to improve performance ORC stated MLSS is generally 4000 mg/L within the oxidation ditch Sludge is wasted about three days a week Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? M ❑ ❑ ❑ Are weirs level? N ❑ ❑ ❑ Is the site free of weir blockage? 0 ❑ ❑ ❑ Is the site free of evidence of short-circuiting? 0 ❑ ❑ ❑ Is scum removal adequate? M ❑ ❑ ❑ Is the site free of excessive floating sludge? 0 ❑ ❑ ❑ Is the drive unit operational? N ❑ ❑ ❑ Is the return rate acceptable (low turbulence)? ❑ ❑ ❑ 0 Is the overflow clear of excessive solids/pin floc? 0 ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately % of the sidewall depth) ❑ ❑ ❑ M Comment Fiber glass weirs were leveled and Datched five vears ago Effluent from clarifier aDDeared free of visible solids. No apparent build-up in center well ORC reports they clean out the center well as needed. Pumps -RAS -WAS Yes No NA NE Are pumps in place? 0 ❑ ❑ ❑ Are pumps operational? M ❑ ❑ ❑ Are there adequate spare parts and supplies on site? 0 ❑ ❑ ❑ Comment Two RAS pumps in operation. One RAS pump recently replaced. ORC states they have budgeted to replace the second RAS pump The WAS pump is in good condition Aerobic Digester Is the capacity adequate? Yes No NA NE ■ ❑ ❑ ❑ Page# 6 Permit N00021547 Inspection Date. 06/07/2017 Owner - Facility: Franklin WWTP Inspection Type Compliance Evaluation Aerobic Digester Yes No NA NE Is the mixing adequate? M ❑ ❑ ❑ Is the site free of excessive foaming In the tank? 0 ❑ ❑ ❑ # Is the odor acceptable? 0 ❑ ❑ ❑ # Is tankage available for properly waste sludge? 0 ❑ ❑ ❑ Comment 1 MGD aerobic digester, three blower motors (lead, lag, lag) supply air to the 15 diffusers ❑ ❑ Digester is aerated 16-20 hours a day during the summer and 4 hours during the winter N ❑ ❑ months The facility has an approved sludge management plan? M ❑ ❑ Solids Handling Equipment Yes No NA NE Is the equipment operational? E ❑ ❑ ❑ Is the chemical feed equipment operational? N ❑ ❑ ❑ Is storage adequate? 0 ❑ ❑ ❑ Is the site free of high level of solids In filtrate from filter presses or vacuum filters? 0 ❑ ❑ ❑ Is the site free of sludge buildup on belts and/or rollers of filter press? 0 ❑ ❑ ❑ Is the site free of excessive moisture in belt filter press sludge cake? N ❑ ❑ ❑ The facility has an approved sludge management plan? M ❑ ❑ ❑ Comment Belt filter press was not in operation at the time of the Inspection Building Is well maintained and equipment appeared to be clean and free of build-up The press Is used to dry sludge before hauling to the landfill Disinfection -Liquid Yes No NA NE Is there adequate reserve supply of disinfectant? 0 ❑ ❑ ❑ (Sodium Hypochlorite) Is pump feed system operational? 0 ❑ ❑ ❑ Is bulk storage tank containment area adequate? (free of leaks/open drains) 0 ❑ ❑ ❑ Is the level of chlorine residual acceptable? ❑ ❑ ❑ M Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑ 0 Comment Hvpochlonte feed Is flow proportional The residual prior to dechlorination Is not monitored Fecal results are used as an Indicator of chlorine effectiveness ORC states the contact chamber was cleaned of solids five years ago. De -chlorination Yes No NA NE Type of system ? Liquid Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ 0 ❑ Is storage appropriate for cylinders? ❑ ❑ 0 ❑ # Is de -chlorination substance stored away from chlorine containers? 0 ❑ ❑ ❑ Page# 7 Permit NCO021547 Owner - Facility Franklin WWTP Inspection Date 06/07/2017 Inspection Type Compliance Evaluation De -chlorination Yes No NA NE Are the tablets the proper size and type? ❑ ❑ ■ ❑ Comment The liquid sulfur dioxide is stored in a separate room from the hypochlorite Are tablet de -chlorinators operational? ❑ ❑ M ❑ Number of tubes in use? Comment Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ® ❑ ❑ ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? M ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6 0 degrees M ❑ ❑ ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type ❑ ❑ ❑ representative)? Comment Composite sampler thermometer is calibrated annually Sampler appeared to be new and well maintained Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? M ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? M ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ M ❑ Comment Path is clear down to effluent pipe No visual Impairments of the receiving stream noted at the time of Inspection Standby Power Is automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Yes No NA NE M ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ M ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Page# 8 Permit NCO021547 Inspection Date 06/07/2017 Standby Power Owner - Facility Franklin WWTP Inspection Type Compliance Evaluation Yes No NA NE Comment This facility has two on-site generators One located at the headworks and one for the WWTP and buildings on-site Both generators self -test on Wednesday under load Generator self -tested during the Inspection Other Yes No NA NE Comment A bypass was noted during the inspection A manhole directly before the chlorine contact basin was slowly leaking secondary effluent See summary and attached NOV for details Page#