Loading...
HomeMy WebLinkAboutNC0003468_Seep Pollutant Analysis_20170607k DUKE ENERGY. May 26, 2017 RECE1\17)IN rIDEWWR Mr. Jeffrey O. Poupart JUN 0 7 2017 NC DEQ - DWR 1617 Mail Service Center 1Natel "Duality Raleigh, NC 27699-1617 Permitting Section Subject: Seep Pollutant Analysis Dan River Steam Station — NPDES Permit #NC0003468 Rockingham County Dear Mr. Poupart: Dan River Combined Cycle Duke Energy Carolinas 900 South Edgewood Road Eden, NC 27288 Pursuant to Part I, Condition A.(23) of the above -referenced permit, Duke Energy Carolinas LLC (Duke Energy) is required to demonstrate that the water quality standards for constituents listed in permit condition A.(19) are not contravened in the receiving stream. This demonstration is required to be completed within 180 days of the effective date of the subject permit using in -stream results at station established in referenced permit. This submittal fulfills the requirement found in condition A.(23). Seeps at Dan River Combined Cycle Station are permitted as Outfall 102, Outfall 103, and Outfall 104. Outfall 102 and Outfall 103 discharge to Railroad Branch and Outfall 104 discharges to the Dan River. Outfall 102 is the only outfall which has had flow since the effective date of the subject permit. Samples collected from Outfall 102 have not exceeded water quality standards for Class C waters found in 15A NCAC 02B .0211, therefore it can be stated that the flows from the seepage outfalls have not caused contravention of water quality standards. Duke Energy has also conducted additional sampling in accordance with the requirements of condition A.(19) to further demonstrate the lack of impact on the receiving water from these flows. This summary of sampling results within the receiving water bodies is provided as an attachment (Table 1 — Seep Pollutant Analysis). These results confirm that Outfall 102, Outfall 103, and Outfall 104 have not caused any contravention of water quality standards for constituents listed in condition A.(19). If you have any questions, please contact Joyce Dishmon @ aoN ce.dishmon@duke-enercN .corn or 336-623-0238. "I certify under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. " Sincerel , Lawrence D. Sparks General Manager II, Regulated Stations Dan River Combined Cycle Power Generating Carolinas East Attachment Cc: Sergei Chernikov, Ph.D. Environmental Engineer II 1617 Mail Service Center, Raleigh, NC 27699-1617 Dana Newcomb, Lead EHS Professional Joyce Dishmon, Sr. Env Specialist, CCP P&C Sherri Knight — Supervisor, DEQ Winston-Salem Regional Office TABLE 1- SEEP POLLUTANT ANALYSIS INSTREAM MONITORING RESULTS DAN RIVER COMBINED CYCLE STATION - NPDES PERMIT: NC0003468 Condition A.(23) compliance demonstration May -17 Dissolved O a Dissolved Dissolved Mercury Dissolved Dissolved Dissolved Hardness, Arsenic, Selenium, USEPA Chromium, Dissolved Cadmium, Copper, Dissolved mg/I Date Location ug/I ug/I 1631E, ng/I ug/I Lead, ug/I ug/I ug/I Zinc, ug/I (CaCO3) T D-10 T7 D-5 T D-12 A/C- A/C- A/C- A C- NCAC 26 Standards Dan River ug/I/NA ug/I/NA ng/I/NA 180/24 14/0.54 0.82/0.15 3.6/2.7 A/C - 36/36 N/A 5/16/2017 Dan River Upstream <1 <1 1.4 <1 <1 <0.1 <1 <5 25.8 5/16/2017 Dan River Downstream <1 <1 1.83 <1 <1 <0.1 <1 <5 25.8 5/16/2017 Railroad Branch Upstream <1 <1 1.44 <1 <1 <0.1 <1 <5 41.5 5/16/2017 Railroad Branch Downstream 1.92 <1 1.45 <1 <1 <0.1 <1 <5 50.9 notes: mg/I - milligrams per liter (parts per million) ug/I - micrograms per liter (parts per billion) ng/I - nanograms per liter (parts per trillion) A/C - Acute/Chronic T/D - Total/Dissolved 9 r � , .. 'e. ,�• rteda . t �! n auren Rd Bhdge 'l L Plb 705 0 E,KrN : o. G oar rt 1 �y ,Ata Y