HomeMy WebLinkAboutNC0020184_Compliance Evaluation Inspection_20170526Water Resources
ENVE3iONMENTAI. QUAUT`4"
May 26, 2017
Ms. Stephanie Scheringer, Division Manager
Two Rivers Utilities
P.O. Box 1748
Gastonia, NC 28053
Dear Ms. Scheringer:
ROY COOPER
Governor
MICHAEL S. REGAN
Secretary
S. JAY ZIMMERMAN
Director
Subject: Compliance Evaluation Inspection
Long Creek WWTP
NPDES Permit No, NCO020184
Gaston County
Enclosed is a copy of the Compliance Evaluation Inspection for the inspection conducted at
the subject facility on May 24, 2017; by Ori Tuvia and Maria Schutte. David Shellenbarger's, Doug
Barker's, and Charlie Graham's cooperation during the site visit was much appreciated. Please
advise the staff involved with this NPDES Permit by forwarding a copy of the enclosed report.
The report should be self-explanatory; however, should you have any questions concerning
this report, please do not hesitate to contact Ori Tuvia at (704) 235-2190, or at
ori.tuvia ncdenr., ov.
Cc: NPDES Unit
MRO Files
Sincerely,
Ori Tuvia, Environmental Engineer
Mooresville Regional Office
Division of Water Resources, DEQ
Mooresville Regional Office
Location: 610 East Center Ave., Suite 301 Mooresville, NC 28115
Phone: (704) 663-16991 Fax: (704) 663.60441 Customer Service: 1-877-623-6748
United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN 1 2 15 1 3 1 NCO020184 111 121 17/05/24 117 181,,l 19I s I 201 I
211111.1) 11111111 1 11 111 1111 1 111111 11111111111 I66
I
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA --Reserved-
Reserved
67 1.0 7014 1 71 1 �, 1 72 1 N 1 731 1 174 75III J_U80
67
L_J L-1 I I I
Section B: FacilityData
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES Permit Number)
09:30AM 17/05/24
17/04/01
Long Creek WWTP
3000 Long Creek Disposal Plant Rd
Exit Time/Date
Permit Expiration Date
Dallas NC 28034
01:15PM 17/05/24
20/01/31
Name(s) of Onsite Representative(s)/Tities(s)/Phone and Fax Number(s)
Other Facility Data
1//
Douglas Edward Barker/ORC/704-9224086/
Name, Address of Responsible OfficiaUTitle/Phone and Fax Number
Contacted
Larry Wayne Cummings,PO Box 1748 Gastonia NC
280531748/1704-866-6991/7048667719 No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit N Flow Measurement Operations & Maintenance Records/Reports
Self-Monitoring Program N Sludge Handling Disposal Facility Site Review Effluent/Reoeiving Waters
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Offioe/Phons and Fax Numbers Date
Ori A Tuvia MRO WQ11704-663-1699/
David G Schlobohm Non Discharge Permitting UniU/919-807-
Signature of Management Q A Reviewer Agency/Offioe/Phone and Fax Numbers Date
y
Andrew Pitne MRO WQ004-663-1699 Ext.21
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#
NPDES yr/mo/day Inspection Type
NCO020184 �11 121 17/05/24 17 18 ICI
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Page#
Permit: NCO020184 Owner -Facility: Long Creek WWTP
Inspection Date: 05/24/2017 Inspection Type: Compliance Evaluation
Yes No NA NE
Are records kept and maintained as required by the permit?
M
❑
Permit
Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
.
❑
❑
❑
application?
M
❑
❑
❑
Is the facility as described in the permit?
M
❑
❑
❑
# Are there any special conditions for the permit?
❑
0
❑
❑
Is access to the plant site restricted to the general public?
■
❑
❑
❑
Is the inspector granted access to all areas for inspection?
0
❑
❑
❑
Comment: The subject permit expires on 1/31/2020.
Record Keeping
Yes No NA NE
Are records kept and maintained as required by the permit?
M
❑
❑
❑
Is all required information readily available, complete and current?
0
❑
❑
❑
Are all records maintained for 3 years (lab. reg. required 5 years)?
M
❑
❑
❑
Are analytical results consistent with data reported on DMRs?
I
❑
❑
❑.
Is the chain -of -custody complete?
0
❑
❑
❑
Dates, times and location of sampling
COCs, visitation logs, calibration logs and bench sheets were reviewed for the
period June
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
0
❑
❑
❑
Has the facility submitted its annual compliance report to users and DWQ?
❑
❑
❑
M
(If the facility is = or > 5 MGD permitted flow) Do they operate 2417 with a certified operator
❑
❑
❑
on each shift?
Is the ORC visitation log available and current?
❑
❑
❑
Is the ORC certified at grade equal to or higher than the facility classification?
❑
❑
❑
Is the backup operator certified at one grade less or greater than the facility classification?
0
❑
❑
❑
Is a copy of the current NPDES permit available on site?
0
❑
❑
❑
Facility has copy of previous year's Annual Report on file for review?
❑
❑
❑
■
Comment: The records reviewed during the inspection were organized and well maintained. DMRs,
COCs, visitation logs, calibration logs and bench sheets were reviewed for the
period June
2016 through April 2017.
Laboratory
Yes No NA NE
Page# 3
Permit: NCO020184
Inspection Date: 05/24/2017
Owner - Facility: Long Creek wWrP
Inspection Type: Compliance Evaluation
Laboratory
Yes No NA NE
Are field parameters performed by certified personnel or laboratory?
0
❑
❑
❑
Are all other parameters(excluding field parameters) performed by a certified lab?
■
❑
❑
❑
# Is the facility using a contract lab?
N
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
M
❑
❑
❑
Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ ■ ❑
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ ■ ❑
Comment: Influent and effluent analyses(including field are performed under the City's Crowders
Creek laboratory certification 1210). Meritech, Inc. 41295 (toxicity) and Shealy
Environmental 4329 Hardnes PPA or anics Cyanide and chloroform have also been
contracted to provide analytical support. The laboratory instrumentation used for field
analyses appeared to be properly calibrated and documented.
Influent Sampling
Yes No NA NE
# Is composite sampling flow proportional?
■
❑
❑
❑
Is sample collected above side streams?
■
❑
❑
❑
Is proper volume collected?
M
❑
M.
❑
Is the tubing clean?
■
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
■
❑
❑
❑
Celsius)?
❑
❑
❑
Is sampling performed according to the permit?
❑
❑
❑
Comment: Permit requires both influent composite samples and grab sampling.
Aliquot sample taken duringthe he inspection pulled 210 ml,
Effluent Samplinq
Yes No NA NE
Is composite sampling flow proportional?
M
❑
❑
❑
Is sample collected below all treatment units?
M
❑
❑
❑
Is proper volume collected?
M
❑
❑
❑
Is the tubing clean?
■
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
❑
❑
❑
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
M
❑
❑
❑
representative)?
Comment: Permit requires both effluent composite samples (flow proportional) and
grab sampling
Aliquot sample taken during the inspection pulled 200 ml.
Upstream / Downstream Sam>31ing
Yes No NA NE
Page# 4
. Permit: N00020184 Owner -Facility: Long Creek WVVrP
Inspection Date: 05/24/2017 Inspection Type: Compliance Evaluation
Upstream / Downstream SampIing Yes No NA NE
Is the facility sampling performed as required by the permit (frequency, sampling type, and ❑ ❑ ❑
sampling location)?
Comment:
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? ■ ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable 0 ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: The facility appeared to be properly operated and well maintained. Theo erations staff
incorporate a comprehensive process control ,program.with all documentation being_ properly_
documented and maintained on-site. The facility is equipped with a SCADA system to assist
the operations staff with the monitoHna of treatment processes and units.
Bar Screens
Yes No NA NE
Type of bar screen
0
❑
❑
❑
a.Manual
❑
❑
❑
❑
b.Mechanical
Are the bars adequately screening debris?
M
❑
❑
❑
Is the screen free of excessive debris?
®
❑
❑
❑
Is disposal of screening in compliance?
M
❑
❑
❑
Is the unit in good condition?
■
❑
❑
❑
Comment: Screenings and grit are disposed at the county Landfill.
Grit Removal
Yes No NA NE
Type of grit removal
0
❑
❑
❑
a.Manual
❑
❑
❑
❑
b.Mechanical
Is the grit free of excessive organic matter?
M
❑
❑
❑
Is the grit free of excessive odor?
N
❑
❑
❑
# Is disposal of grit in compliance?
0
❑
❑
❑
Comment: Screenings and grit are. disposed at the county landfill.
Pump Station - Influent
Yes No NA NE
Is the pump wet well free of bypass lines or structures?
0
❑
❑
❑
Is the wet well free of excessive grease?
M
❑
❑
❑
Page# 5
Permit: NCO020184
Inspection Date: 05/24/2017
Owner -Facility: Long Creek VWVfP
Inspection Type: Compliance Evaluation
Is the clarifier free of black and odorous wastewater?
0
❑
Pump Station - Influent
Yes No NA NE
Are all pumps present?
0
❑
❑
❑
Are all pumps operable?
N
❑
❑
❑
Are float controls operable?
0
❑
❑
❑
Is SCADA telemetry available and operational?
N
❑
❑
❑
Is audible and visual alarm available and operational?
0
❑
❑
M
Comment: 4 of the 5 pumps were in operation during the inspection one pump was out for
maintenance.
Primary Clarifier
Yes No NA NE
Is the clarifier free of black and odorous wastewater?
0
❑
❑
❑
Is the site free of excessive buildup of solids in center well of circular clarifier?
N
❑
❑
❑
Are weirs level?
E
❑
❑
❑
Is the site free of weir blockage?
0
❑
❑
❑
Is the site free of evidence of short-circuiting?
N
❑
❑
❑
Is scum removal adequate?
t
❑
❑
❑
Is the site free of excessive floating sludge?
M
❑
❑
❑
Is the drive unit operational?
S
❑
❑
❑
Is the sludge blanket level acceptable?
S
❑
❑
❑
Is the sludge blanket level acceptable? (Approximately % of the sidewall depth)
0
❑
❑
❑
Comment: One of three primaries was in service all operational)_
Nutrient Removal
Yes No NA NE
# Is total nitrogen removal required?
0 ❑
❑
❑
# Is total phosphorous removal required?
0 ❑
❑
❑
Type
Biological
# Is chemical feed required to sustain process?
0 ❑
❑
❑
Is nutrient removal process operating properly?
N ❑
❑
❑
Comment: The facility, combined with Eagle Road VWVTP are required to comply with a summer {April
1 - October 31) effluent total nitrogen loading limit f214,171, Ib/season as well as winter
'November 1 — March 31) effluent total nitrogen loading limit X302,242 Ib/season). The
combined facilities also have a year around effluent total phosphorus loading limit (60,882
Ib/year). Nutrient removal is performed biologically and chemically alum
Aeration Basins Yes No NA NE
Mode of operation Ext. Air
Page# 6
Permit: NCO020184
Inspection Date: 05/24/2017
Aeration Basins
Type of aeration system
Is the basin free of dead spots?
Are surface aerators and mixers operational?
Are the diffusers operational?
Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin's surface?
Is the DO level acceptable?
Is the DO level acceptable?(1.0 to 3.0 mg/1)
Owner -Facility: Long Creek WWTP
Inspection Type: Compliance Evaluation
Yes No NA NE
Diffused
M ❑ ❑ ❑
0 ❑ ❑ ❑
■ ❑ ❑ ❑
0 ❑ ❑ ❑
■ ❑ ❑ ❑
r ❑ ❑ ❑
M ❑ ❑ ❑
Comment: 3 of the 4 aeration tracks were in operation during the inspection one track was out for
maintenance.
Yes No NA NE
Is the clarifier free of black and odorous wastewater?
M
❑
Chemical Feed
Yes No NA NE
Is containment adequate?
0
❑
❑
❑
Is storage adequate?
M
❑
❑
❑
Are backup pumps available?
■
❑
❑
❑
Is the site free of excessive leaking?
0
❑
❑
❑
Comment:
Secondary Clarifier
Yes No NA NE
Is the clarifier free of black and odorous wastewater?
M
❑
❑
❑
Is the site free of excessive buildup of solids in center well of circular clarifier?
M
❑
❑
❑
Are weirs level?
■
❑
❑
❑
Is the site free of weir blockage?
M
❑
❑
❑
Is the site free of evidence of short-circuiting?
■
❑
❑
❑
Is scum removal adequate?
M
❑
❑
❑
Is the site free of excessive floating sludge?
■
❑
❑
❑
Is the drive unit operational?
■
❑
❑
❑
Is the return rate acceptable (low turbulence)?
■
❑
❑
❑
Is the overflow clear of excessive solids/pin floc?
■
❑
❑
❑
Is the sludge blanket level acceptable? (Approximately % of the sidewall depth)
0
❑
❑
❑
Comment: Three of four secondaries were in service (all operational).
Filtration (High_ Rate_ Tertiary)
Type of operation:
Yes No NA NE
Down flow
Page# 7
Permit: NC0020184
Owner -Facility: Long Creek WWTP
Are cylinders secured adequately?
Gas
❑
Inspection Date: 05/24/2017
Inspection Type: Compliance Evaluation
Are cylinders protected from direct sunlight?
❑
Filtration (High Rate Tertiary)
Yes No NA NE
Is the filter media present?
N
❑
❑
❑
Is the filter surface free of clogging?
N
❑
❑
❑
Is the filter free of growth?
■
❑
❑
❑
Is the air scour operational?
E
❑
❑
❑
Is the scouring acceptable?
■
❑
❑
❑
Is the clear well free of excessive solids and filter media?
®
❑
❑
❑
Comment: all eight tertiary filters were in service.
Disinfection -Gas
Yes No NA NE
Are cylinders secured adequately?
Gas
❑
❑
❑
Are cylinders protected from direct sunlight?
❑
❑
❑
Is there adequate reserve supply of disinfectant?
0
❑
❑
❑
Is the level of chlorine residual acceptable?
N
❑
❑
❑
Is the contact chamber free of growth, or sludge buildup?
N
❑
❑
❑
Is there chlorine residual prior to de -chlorination?
0
❑
❑
❑
Does the Stationary Source have more than 2500 lbs of Chlorine (CAS No. 7782-50-5)?
■
❑
❑
❑
If yes, then is there a Risk Management Plan on site?
❑
❑
❑
0
If yes, then what is the EPA twelve digit ID Number? (1000- -_)
1000-0006-7367
If yes, then when was the RMP last updated?
Comment:
De -chlorination
Yes No NA NE
Type of system ?
Gas
Is the feed ratio proportional to chlorine amount (1 to 1)?
❑
❑
❑
Is storage appropriate for cylinders?
❑
❑
❑
# Is de -chlorination substance stored away from chlorine containers?
❑
■
❑
❑
Are the tablets the proper size and type?
❑
❑
■
❑
Comment: One ton cylinders are stored outside together under cover
Are tablet de -chlorinators operational?
❑
❑
■
❑
Number of tubes in use?
Comment:
Page# 8
Permit: NCO020184
Inspection Date: 05/24/2017
Owner -Facility: Long Creek WWTP
Inspection Type: Compliance Evaluation
# Is flow meter used for reporting?
■
❑
Pumas -RAS -WAS
Yes No NA NE
Are pumps in place?
■
❑
❑
❑
Are pumps operational?
■
❑
❑
❑
Are there adequate spare parts and supplies on site?
r
❑
❑
❑
Comment:
Flow Measurement - Effluent
Yes No NA NE
# Is flow meter used for reporting?
■
❑
❑
❑
Is flow meter calibrated annually?
M
❑
❑
❑
Is the flow meter operational?
■
❑
❑
❑
(If units are separated) Does the chart recorder match the flow meter?
■
❑
❑
❑
Comment: The influent and effluent flow meters are calibrated/verified twice Der near and were last
calibrated/verifed on 12/20/2016 by Fortech Automation Encineering,
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained? ❑ ❑ ❑ M
Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ ❑ ■
If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ ❑ M
Comment: Effluent leaving the WWTP appeared clear with no floatable solids or foam. Effluent pipe
was not examined during the inspection.
Anaerobic Digester
Yes No NA NE
Type of operation:
Fixed cover
Is the capacity adequate?
0 ❑
❑
❑
# Is gas stored on site?
❑ ❑
❑
■
Is the digester(s) free of tilting covers?
❑
❑
❑
Is the gas burner operational?
❑ ❑
❑
■
Is the digester heated?
❑ ❑
❑
0
Is the temperature maintained constantly?
❑ ❑
❑
■
Is tankage available for properly waste sludge?
■ ❑
❑
❑
Comment: Waste activated sludge (WAS) is thickened in a DAF unit prior to being
pumped to the
digesters. The facility is ecuigped with six anaerobic digesters (4 -primary,
3 in operation
and 2 -secondary). Bio -solids are land applied by a contracted company
(EMA) under the
authority of Permit No. W00001793.
Lagoons
Yes No NA NE
Page# 9
Permit: NC0020184
Inspection Date: 05/24/2017
La -goons
Type of lagoons?
# Number of lagoons in operation at time of visit?
Are lagoons operated in?
# Is a re -circulation line present?
Is lagoon free of excessive floating materials?
# Are baffles between ponds or effluent baffles adjustable?
Owner -Facility: Long CreekWWTP
Inspection Type: Compliance Evaluation
Are dike slopes clear of woody vegetation?
Are weeds controlled around the edge of the lagoon?
Are dikes free of seepage?
Are dikes free of erosion?
Are dikes free of burrowing animals?
# Has the sludge blanket in the lagoon (s) been measured periodically in multiple
locations?
# If excessive algae is present, has barley straw been used to help control the growth?
Is the lagoon surface free of weeds?
Is the lagoon free of short circuiting?
Comment: The facility is eguipped with two lagoons used for bio -solids storage (prior to land
application).
Standby Power
Is automatically activated standby power available?
Is the generator tested by interrupting primary power source?
Is the generator tested under load?
Was generator tested & operational during the inspection?
Do the generator(s) have adequate capacity to operate the entire wastewater site?
Is there an emergency agreement with a fuel vendor for extended run on back-up power?
Is the generator fuel level monitored?
Yes No NA NE
2
Series
❑ ❑ M ❑
■ ❑ ❑ ❑
❑ ❑ ■ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ M ❑
❑ ❑ ■ ❑
❑ ❑ M ❑
M ❑ ❑ ❑
❑ ❑ ■ ❑
Yes No NA NE
■ ❑ ❑ ❑
M ❑ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ❑ M
■ ❑ ❑ ❑
■ ❑ ❑ ❑
E ❑ ❑ ❑
Comment: The facility -is eguipped with three standby generators that are placed under load at leat once
per month (peak shaving/storm events)
Page# 10