Loading...
HomeMy WebLinkAboutNC0050610_Renewal (Application)_20170523Water Resources ENVIRONMENTAL QUALITY ROY COOPER Govemor MICHAEL S. REGAN Secrelary S. JAY ZIMMERMAN Direclor May 23, 2017 Mr. Jadd W. Brewer Water Quality Utilities, Inc. PO Box 384 Banner Elk, NC 28605 Subject: Permit Renewal Application Application No. NCO05061.0 The Pond WWTP Watauga County Dear Mr. Brewer: The Water Quality Permitting Section acknowledges receipt of your permit application and supporting documentation received on May 19, 2017. The primary reviewer for this renewal application is Emily Phillips. The primary reviewer will review your application, and she will contact you if additional information is required to complete your permit renewal. Per G.S. 150B-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit. Please respond in a timely manner to requests for additional information necessary to complete the permit application. If you have any additional questions concerning renewal of the subject permit, please contact Emily at 919-807-6479 or Sarah.Phillips@ncdenr.gov. Sincerely, Wren Thedford Wastewater Branch cc: Central Files NPDES Winston-Salem Regional Office State of North Carolina I Environmental Quality I Water Resources 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 919-807-6300 NC DENR / DWR / NPDES Renewal Application Checklist RECEIVEDINCDEQIDWR MAY 19 2017 The following items are REQUIRED for all renewal packages: Water Quality Permitting Section o A cover letter requesting renewal of the pen -nit and documenting any changes at the facility since issuance of the last permit. Submit one signed original and two copies. o The completed application form (copy attached), signed by the permittee or an Authorized Representative. Submit one signed original and two copies. o If an Authorized Representative (such as a consulting engineer or environmental consultant) prepares the renewal package, written documentation must be provided showing the authority delegated to the Authorized Representative (see Part II.B.1 Lb of the existing NPDES permit). o A narrative description of the sludge management plan for the facility. Describe how sludge (or other solids) generated during wastewater treatment are handled and disposed. If your facility has no such plan (or the permitted facility does not generate any solids), explain this in writing. Submit one signed original and two copies. The following items must be submitted by any Municipal or Industrial facilities discharging process wastewater. o Industrial facilities classified as Primary Industries (see Appendices A D to Title 40 of the Code of Federal Regulations, Part 122) and ALL Municipal facilities with a permitted flow >_ 1.0 MGD must submit a Priority Pollutant Analysis (PPA) in accordance with 40 CFR Part 122.21. The above requirement does NOT apply to non industrial facilities. Send the completed renewal package to: Wren Thedford NC DENR / DWR / NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Water Quality Lab & Operations, Inc. P.O. Box 1167/1522 Tynecastle Highway Banner Elk, NC 28604 Ph. 828-898-6277 Fax 828-898-6255 May 3, 2017 Wren Thedford NCDENR/DWR/NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Re: The Ponds Permit Renewal Mr. Thedford: Please find enclosed an application for the permit renewal for The Ponds WWTP. All items on the checklist are included with the permit renewal. There have been no significant changes to the facility since the previous permit cycle. If we can be of further assistance, please do not hesitate to contact us. Sincerely, / Jadd Brewer Owner NPDES APPLICATION - FORM D For privately -owned treatment systems treating 100% domestic wastewaters <1.0 MGD Mail the complete application to: N. C. DENR / Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit ,NCO050610 If you are completing this form in computer use the TAB key or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type. 1. Contact Information: Owner Name Facility Name Mailing Address City State / Zip Code Telephone Number Fax Number e-mail Address Water Quality Utilities The Ponds WWTP P.O. Box 384 Banner Elk NC 28604 (828) 898-6277 (828 )898-6255 waterqualitylab ttyahoo.com 2. Location of facility producing discharge: Check here if same address as above ❑ Street Address or State Road 184 Beech Lane City Foscoe State / Zip Code NC 28607 County Watauga 3. Operator Information: Name of the firm, public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Water Quality Lab and Operations Mailing Address P.O. Box 1167 City State / Zip Code Telephone Number Fax Number Banner Elk NC 28604 (828) 898-6277 (828) 898-6255 e-mail Address waterqualitylabsCyahoo.com 1 of 3 Form -D 11112 NPDES APPLICATION - FORM D For privately -owned treatment systems treating 100% domestic wastewaters <1.0 MGD 4. Description of wastewater: Facility Generating Wastewater(check all that apply): Industrial ❑ Number of Employees Commercial ❑ Number of Employees Residential ® Number of Homes 600+ School ❑ Number of Students/Staff Other ❑ Explain: Describe the source(s) of wastewater (example: subdivision, mobile home park, shopping centers, restaurants, etc.): Subdivision Number of persons served: 639 S. Type of collection system ® Separate (sanitary sewer only) ❑ Combined (storm sewer and sanitary sewer) 6. Outfall Information: Number of separate discharge points 1 Outfall Identification number(s) 001 Is the outfall equipped with a diffuser? ® Yes ❑ No 7. Name of receiving stream(s) (NEW applicants: Provide a map showing the exact location of each outfall): Watauga River in the Watauga River Basin S. Frequency of Discharge: If intermittent: Days per week discharge occurs: Continuous ❑ Intermittent Duration: 9. Describe the treatment system List all installed components, including capacities, provide design removal for BOD, TSS, nitrogen and phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a separate sheet of paper. Influent flow control system with comminutor and bar screen, grit chamber, surge tank, extended aeration chamber with clarifier, tertiary system with W disinfection, now monitor and recorder 2 of 3 Form -D 11/12 NPDES APPLICATION - FORM D For privately -owned treatment systems treating 100% domestic wastewaters <1.0 MGD 10. Flow Information: Treatment Plant Design flow 0.076 ,_MGD Annual Average daily flow 0.0311 MGD (for the previous 3 years) Maximum daily flow 0.077 MGD (for the previous 3 years) 11. Is this facility located on Indian country? ❑ Yes ® No 12. Effluent Data NEW APPLICANTS: Provide data for the parameters listed. Fecal Coliform, Temperature and pH shall be grab samples, for all other parameters 24-hour composite sampling shall be used. If more than one analysis is reported, report daily maximum and monthly average. If only one analysis is reported, report as daily maximum. RENEWAL APPLICANTS: Provide the highest single reading (Daily Maximum) and Monthly Average over the past 36 months for parameters currently in your permit. Mark other pararneters "N/A". Parameter Daily Maximum Monthly Units of Average Measurement Biochemical Oxygen Demand (BOD,) 32.3 15.1 mg/L Fecal Coliform 3500 32 cuf/ 100mL Total Suspended Solids 33 17.3 mg/L 25 Degrees Celcius Temperature (Summer) 25 Temperature (Winter) 15 12.7 Degrees Celcius 7.6 7.4 s/u pH 13. List all permits, construction approvals and/or applications: Type Permit Number Type Permit Number Hazardous Waste (RCRA) NESHAPS (CAA) UIC (SDWA) Ocean Dumping (MPRSA) NPDES NCO050610 Dredge or fill (Section 404 or CWA) PSD (CAA) Other Non -attainment program (CAA) 14. APPLICANT CERTIFICATION I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. Jadd Brewer _ Owner Printed name of Person Signing Title `"j ='''•� _ , _ .�' --� Vii- �.,., � �°` Signature of Applicant Date North Carolina General Statute 143-215.6 (b)(2) states: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) 3 of 3 Form -D 11112 Water Quality Lab & Operations, Inc. P.O. Box 1167/ 1522 Tynecastle Highway Banner Elk, NC 28604 Ph. 828-898-6277 Fax 828-898-6255 THE PONDS WWTP SLUDGE MANAGEMENT Sludge is managed via a commercial hauler, Triple T located on 1372 NC Hwy 194 N, Boone, NC 28607.