HomeMy WebLinkAboutNC0004979_Duke Power Company's 316_19940520Plant Allen, Gaston County NPDES # NC0004979 May 20, 1994 Plant Allen 316(a) Determination Duke Power Company's 316(a) demonstration (March 1976) concluded that the "heated discharge from Plant Allen is such that the protection and propagation of a balanced indigenous aquatic community in and on Lake Wylie is assured." Duke's operation experience during the past five years -under the thermal limitations imposed in NPDES Permit No. NC0004979 substantiates the above conclusion and further supports Duke's 'belief that the operating characteristics of the station have a minimal effect of the aquatic environment of Lake Wylie. Surveys of the aquatic community in Lake Wylie demonstrate that a Balanced Indigenous Population exists in Lake Wylie (see attached report). Accordingly, Duke requests a 316(a) variance and further requests that the thermal limitations imposed in the permit be continued. 0 Plant Allen, Gaston County NPDES # NC0004979 May 20, 1994 LIST OF HAZARDOUS SUBSTANCES (SECTION 311) SUBSTANCE QUANTITY LOCATION USE Ammonia molybdate 2000 gm Lab Water Analysis Acetic acid 1 qt If of Ammonia 1 Ib (gas) Powerhouse Water treatment Ammonium hydroxide 55 gal of of Chlorine 15001b of of Ferric sulfate 360 g Lab Water Analyses Hydrochloric acid 2 gal it" Monoethylamine 6L itWater Analyses Nitric acid 6 qt " Potassium hydroxide 3 Ib " Sodium bisulfite 5 lb Powerhouse Water Treatment Sodium hydroxide 5000 gal Demineralizer regen. Sulfuric acid 5000 gal Yard Demineralizer regen Sulfamic acid 1001b Powerhouse RO unit cleaning Values represent maximum quantities on-site and do not necessarily reflect quantities discharges. Treatment of these and othr chemical substances is achieved by the ash basin. Refer to "NPDES Supplemental Information" for a list of chemicals and amounts used for boiler cleaning. 0 Plant Allen Water Use Schematic Gaston County Cooling Water E D M Misc. Equip. Cooling and Seals Water Treatment L J CATAWBA A Service RIVER F Water c P Screen Backwash Filter B IBackwash K J�N Boiler Room Sumps I Ash I Sluicing E S IT urbine Room Sumps NPDES # NC0004979 001 Sump R T Stormwater (2) Ash Basin 002 x Permanent Lines Temporary Lines Coal Handling Sanitary Sumps Waste v Q Stormwater (1) Coal Yard T Sump j and Drainage Sump R T Stormwater (2) Ash Basin 002 x Permanent Lines Temporary Lines Y� � � Plant Allen, Gaston County NPDES # NC0004979 Water Use Schematic 001 CCW Discharge 428.5 002 Ash Basin Discharge 11.660 003 Misc. Cooling Water 6.340 004 Intake Screen Backwash and Misc Cooling Water 8.010 005 Clamtrap Filter and Debris Backwash 0.018 Flows based on historical data where available. For more information, see "Supplemental Information". Flow Stream AvQ.Flow (MGD) A Intake Water 453.7 B Clam Trap and Debris Filter Backwash 0.003 C Intake Screen Backwash 0.840 D Condenser Cooling Water 428.5 E Water Box Drainage Intermittent F Service Water 24.699 G Boiler Makeup aAter 0.175 H Evaporative losses 0.115 1 Condensate, Seals and Leakage 0.056 J Water Treatment System 0.332 K Water Treatment Waste 0.068 L Misc Equipment Cooling and Seals 17.074 M Boiler Feedpump and Mill Cooling Water 7.170 N Boiler Blowdown 0.004 0 Misc. Equipment Cooling Drains 0.62.1 P Ash Sluicing 7.343 Q Sanitary Waste 0.005 R Boiler Room Sumps 2.965 S Boiler Cleaning Wastes Intermittent T Coal Yard Sump 0.058 U Turbine Room Sumps 0.677 V Coal Handling Sumps (Stormwater and groundwater 0.053 seepage) X Yard Dain Sump 3.689 Y Ash Hopper Seal Overflow 2.893 1 Stormwater 0.018 2 Stormwater 0.570 001 CCW Discharge 428.5 002 Ash Basin Discharge 11.660 003 Misc. Cooling Water 6.340 004 Intake Screen Backwash and Misc Cooling Water 8.010 005 Clamtrap Filter and Debris Backwash 0.018 Flows based on historical data where available. For more information, see "Supplemental Information".