HomeMy WebLinkAbout20080950 Ver 2_More Info Letter_20080912?Q? vv!7 ? ?R? Michael F. Easley, Governor
`o ?i William G. Ross Jr., Secretary
Cp r? North Carolina Department of Environment and Natural Resources
p Coleen H. Sullins, Director
Division of Water Quality
September 12, 2008
DWQ Project # 08-0950, Ver. 2
Wake County
CERTIFIED MAIL: RETURN RECEIPT REQUESTED
Mr. Ronnie Thompson
TT & E Metal and Iron Works, Inc.
508 N. Garner Street
Garner, NC 27529
Subject Property: TT & E Facility Expansion
Ut to Big Branch [030402, 27-34-11, C, NSW]
REQUEST FOR MORE INFORMATION
Dear Mr. Thompson:
On August 7, 2008, the Division of Water Quality (DWQ) received your application dated
August 7, 2008, to fill or otherwise impact 138 linear feet of perennial stream, and 6,825 square
feet of Zone 1 Neuse River basin protected riparian buffers and 4,158 square feet of Zone 2
Neuse River basin protected riparian buffers to construct the proposed facility expansion at the
site. The DWQ has determined that your application was incomplete and/or provided inaccurate
information as discussed below. The DWQ will require additional information in order to
process your application to impact protected wetlands and/or streams on the subject property.
Therefore, unless we receive five copies of the additional information requested below, we will
place this project on hold as incomplete until we receive this additional information. If we do
not receive the requested information, your project will be formally returned as incomplete.
Please provide the following information so that we may continue to review your project.
Additional Information Requested:
Level Spreader #1 (treating Drainage Area #3): The photograph indicates that the filter
strip consists of wooded vegetation, not dense vegetation. Thus, the level spreader (sized
at 13 feet per cfs) is not long enough to handle the flow that is being directed toward it.
Please redesign this portion of the project so that the level spreader length is appropriate
for the type of vegetation in the filter strip. Also, please show a profile of the roadway
and the roadway drainage system. This will assist the DWQ in determining if the flow
can be conveyed to the level spreader based on the topography.
2. Scour Hole #1 (treating the discharge from Scour Hole 41): The slopes within the filter
strip appear to be approximately 4 percent, which exceeds the allowable slopes of 2
percent or less for scour holes. Please provide a level spreader in this location. In your
NorthCarolina
401 Oversight/Express Review Permitting Unit Naturally
1650 Mail Service Center, Raleigh, North Carolina 27699-1650
2321 Crabtree Boulevard, Suite 250, Raleigh, North Carolina 27604
Phone: 919-733-1786 / FAX 919-733-6893 / Internet: httn://h2o.enr.state.nc.us/ncwetlands
An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper
TT & E Metal and Ironworks, Inc.
Page 2 of 2
September 12, 2008
resubmittal, please call out the invert of the discharge point. This will assist the DWQ in
determining if the flow can be conveyed to the level spreader based on the topography.
3. SE Portion of Project: Please provide diffuse flow provisions to convey stormwater from
the impervious surfaces on this part of the project to the receiving stream.
Please submit this information within 30 calendar days of the date of this letter. If we do not
receive this requested information within 30 calendar days of the date of this letter, your project
will be withdrawn and you will need to reapply with a new application and a new fee.
This letter only addresses the application review and does not authorize any impacts to wetlands,
waters or protected buffers. Please be aware that any impacts requested within your application
are not authorized (at this time) by the DWQ. Please call Ms. Cyndi Karoly or Mr. Ian
McMillan at 919-733-1786 if you have any questions regarding or would like to set up a meeting
to discuss this matter.
CBK/ijm
cc: Lauren Witherspoon, DWQ Raleigh Regional Office
USACE Raleigh Regulatory Field Office
File Copy
Central Files
Jennifer A. Burdette, Burdette Land Consulting, Inc., 10212 Creedmoor Road, Raleigh, NC 27615
Filename: 080950Ver2T-F&EFacilityExpansion(Wake)On_Hold
¦ Complete items 1, 2, and 3. Also complete
item 4 if Restricted Delivery is desired.
¦ Print your name and address on the reverse
so that we can return the card to you.
¦ Attach this card to the back of the mailpiece,
or on the front if space permits.
1. Article Addressed to:
T T & E Metal and Iron Works, Inc.
Attn: Mr. Ronnie Thompson
508 N. Garner Street
Garner, NC 27529
DWQ# 08-0950-v2-Wake
A. Signature
I
X c ? Agent
d
- dressee
Received?Printed Name) ate f D i ery
D. Is delivery addrers d 1 .
p ? Yes
If YES, enter deliveraddre
,
ss ? No
)
u7
3. rvice Type
Certified Mail ? Express Mail
Registered Return Receipt for Merchandise
? Insured Mail 9C
O
D
.
.
.
4. Restricted Delivery? (Extra Fee)
? Yes
2. Article Number
(Transfer from service 7008 1320 0001, 2224 81,63
PS Form 3811, February 2004 Domestic Return Receipt 102695-02•M-1640
UNITED STATES POSTAL SERVICE
LISPS
• Sender: Please print your name, address, and ZIP+4 in this box •
NC DENR Division of Water Quality
401 Oversight/Express Unit
2321 Crabtree Boulevard, Suite 250
Raleigh, NC 27604
First-Class Mail
Postage & Fees Paid
Permit No. G-10