Loading...
HomeMy WebLinkAbout20150717 Ver 2_PCN Attachments_20170508USACE Pre-Construction Notification –NWP 18 Duke Energy Carolinas, LLC Dan River Steam Station 48-inch Inlet Area Clean-Up Rockingham County, NC ATTACHMENTS Figure 1 Site Location Map Figure 2 Aerial Photograph Figure 3 NRCS Soils Map Figure 4 USFWS NWI Map Figure 5 SHPO Map Figure 6 FEMA 100-Year Floodplain Map Attachment A –Project Description Plan View drawing Cross-Section drawing Stormwater Diversion drawing DENR Low Density Supplement Form USFWS Information, Planning, and Conservation System (IPaC)database search results Approval letter from NC Division of Mitigation Services -In-Lieu Fee Program USACE Permit Number SAW -2014-01477 (issued 9/29/2014) for the Dan River Steam Station “36-inch Culvert Plug” project (project impacts to WOUS = 0.098 acre wetlands and 65 LF stream) PREPAREDBY DATE CHECKEDBY DATE JOB NUMBER FIGURE 16226-14-0004.02.022 Source: USGS 24k Map Sheets, Southeast Eden and Northeast Eden. Copyright:© 2013 National Geographic Society, i-cubed r PROJECT AREA JMB 8/11/2014 RGH 8/11/2014 SITE LOCATION MAP48-INCH INLET AREA CLEAN-UPDUKE ENERGY DAN RIVER STEAM STATIONROCKINGHAM COUNTY, NORTH CAROLINA ^_ NORTH CAROLINA Project Location 0 1,000 2,000500Feet PREPAREDBY DATE CHECKEDBY DATE JOB NUMBER FIGURE 26226-14-0004.02.022 Source: http://goto.arcgisonline.com/maps/World_Imagery, accessed July 1, 2014. D a n R i v e r S E D G E W O O D R D R O S E W O O D L N Source: Esri, DigitalGlobe, GeoEye, i-cubed, USDA, USGS, AEX,Getmapping, Aerogrid, IGN, IGP, swisstopo, and the GIS User Community r PROJECT AREA JMB 8/11/2014 RGH 8/11/2014 AERIAL PHOTOGRAPH48-INCH INLET AREA CLEAN-UPDUKE ENERGY DAN RIVER STEAM STATIONROCKINGHAM COUNTY, NORTH CAROLINA 0 500 1,000250Feet PREPAREDBY DATE CHECKEDBY DATE JOB NUMBER FIGURE 36226-14-0004.02.022 Source: http://goto.arcgisonline.com/maps/World_Imagery, accessed July 1, 2014; USDA NRCS Soil Survey Geographic (SSURGO) database for Rockingham County, North Carolina, dated December 21, 2013. D a n R i v e r DaA W CmB HbA DaA CmB AyC W SvB Ud SvD PnF W CmD AyF CsA CmD AyF Source: Esri, DigitalGlobe, GeoEye, i-cubed, USDA, USGS, AEX,Getmapping, Aerogrid, IGN, IGP, swisstopo, and the GIS User Community r PROJECT AREA JMB 8/11/2014 RGH 8/11/2014 NRCS SOILS MAP48-INCH INLET AREA CLEAN-UPDUKE ENERGY DAN RIVER STEAM STATIONROCKINGHAM COUNTY, NORTH CAROLINA 0 500 1,000250Feet Map Symbol Description AyC Ayersville gravelly loam, 4 to 15 percent slopesAyF Ayersville gravelly loam, 15 to 45 percent slopesCmB Clover sandy loam, 2 to 8 percent slopes CmD Clover sandy loam, 8 to 15 percent slopesDaA Dan River loam, 0 to 2 percent slopes, frequently flooded SvB Stoneville loam, 2 to 8 percent slopesSvD Stoneville loam, 8 to 15 percent slopesUd Udorthents, loamy W Water Soil Type Boundary PREPAREDBY DATE CHECKEDBY DATE JOB NUMBER FIGURE 46226-14-0004.02.022 Source: http://goto.arcgisonline.com/maps/World_Imagery, accessed July 1, 2014; U.S. Fish and Wildlife Service, National Wetlands Inventory GISdatabase, dated May 1, 2014. D a n R i v e r PUBHx R2UBH PUBHx PUBHh PUBHhPUSCh Source: Esri, DigitalGlobe, GeoEye, i-cubed, USDA, USGS, AEX,Getmapping, Aerogrid, IGN, IGP, swisstopo, and the GIS User Community r PROJECT AREA JMB 8/11/2014 RGH 8/11/2014 USFWS NWI MAP48-INCH INLET AREA CLEAN-UPDUKE ENERGY DAN RIVER STEAM STATIONROCKINGHAM COUNTY, NORTH CAROLINA 0 500 1,000250Feet Freshwater Pond Other Riverine NWI Classification DescriptionPUBHh Palustrine, Unconsolidated Bottom, Permanently Flooded, Diked/Impounded PUBHx Palustrine, Unconsolidated Bottom, Permanently Flooded, ExcavatedPUSCh Palustrine, Unconsolidated Shore, Seasonally Flooded, Diked/ImpoundedR2UBH Riverine, Lower Perennial, Unconsolidated Bottom, Permanently Flooded PREPAREDBY DATE CHECKEDBY DATE JOB NUMBER FIGURE 56226-14-0004.02.022 Source: http://goto.arcgisonline.com/maps/World_Imagery, accessed July 1, 2014; North Carolina Department of Cultural Resources, State Historic Preservation Office interactive web site (HPOWEB); accessed June 27, 2014. D a n R i v e r T O W N C R E E K RD Source: Esri, DigitalGlobe, GeoEye, i-cubed, USDA, USGS, AEX,Getmapping, Aerogrid, IGN, IGP, swisstopo, and the GIS User Community r PROJECT AREA JMB 8/11/2014 RGH 8/11/2014 SHPO MAP48-INCH INLET AREA CLEAN-UPDUKE ENERGY DAN RIVER STEAM STATIONROCKINGHAM COUNTY, NORTH CAROLINA 0 750 1,500375Feet PREPAREDBY DATE CHECKEDBY DATE JOB NUMBER FIGURE 66226-14-0004.02.022 Source: http://goto.arcgisonline.com/maps/World_Imagery, accessed July 1, 2014; FEMA/FIRM Map Numbers 3710798900J, 3710799900J, and 3710709000J, dated July 3, 2007. D a n R i v e r S E D G E W O O D R D R O S E W O O D L N Source: Esri, DigitalGlobe, GeoEye, i-cubed, USDA, USGS, AEX,Getmapping, Aerogrid, IGN, IGP, swisstopo, and the GIS User Community r PROJECT AREA JMB 8/11/2014 RGH 8/11/2014 FEMA 100-YEAR FLOODPLAIN MAP48-INCH INLET AREA CLEAN-UPDUKE ENERGY DAN RIVER STEAM STATIONROCKINGHAM COUNTY, NORTH CAROLINA 0 500 1,000250Feet 100-Year Floodplain 500-Year Floodplain Attachment A Project Description This project is to provide for the clean-up of ash and the temporary impoundment of storm water at the grouted 48 inch reinforced concrete pipe that drains a n 18.6 acre drainage area just upstream of the existing Primary Ash Basin at Dan River Steam Station in Eden, North Carolina. The impacts to the stream include the temporary inundation of the wetlands following storm events and the clean-up of coal combustion products released into the area during the downstream fail ure of the 48-inch pipe. Calculations indicate that the wetland area can store the 25 -year storm event up to elevation 525.0 without discharge. Pumping capacity currently provided allows for the temporarily impounded water to be drawn back down within 72 hours of the storm event. Pumped flows will be discharged to the Service Water Settling Pond by way of existing piping to a proposed new storm water outfall . 1X PROPOSED EXTENTS OF TEMPORARY TEMPORARY IMPACTS 1�I IMPOUNDMENT BASED ON 25 -YEAR �= X —vj Wetland 1 12,420.9 SQ.FT. EVENT RUNOFF STORAGE ( EL. 524) c \ \ Wetland 2 5,299.3 SQ.FT. _ — Total 17,720.2 SQ.FT. (DEWATER BY PUMPING WITHIN 72 _ — woo= =mom _ � HOURS OF RAIN EVENT) � \ Stream 1 219 FT. _ — — low — _ _ .000'Stream 2 97 FT. / t S ream 3 132 FT. -- - - - - - - � Total 448 FT. EXISTING 48 -INCH CORRUGATED - - METAL PIPE (CMP) CULVERT HAS - _ BEEN GROUTED. INFLOWS WILL ° .\ �`� BE PUMPED TO SECONDARY ASH `. ; ; o��� BASIN SHORT-TERM AND LATER %. TO NEW STORMWATER OUTFALL % % I _ - \ FOLLOWING CLEAN-UP. TEMOPORARILY \ \ I ► '� IMPACTED STREAM 3 �,' -.��� (APPROX. 132 FT.) I � J � %� - A+ I A p `+ 4- n_ -- cat�4 is - t � Lo 1 pPCQxima to e. \ TEMPORARILY IMPACTED WETLAND 2�.. ,' ' I I ; X, \. (APPROX. 5,299.3 SQ.FT. °i „ *' + + I` x IMPACTED OF 8,155 + a / ' i � � I 1. '. � '� \, SQ.FT. OF WETLANDS) EMPORARILY %. I\ •+ �, + IMPACTED STREAM 2 �,. _ • �.� (APPROX. 97 FT.) - TEMPORARILY - _ , _ 0100' - �_- `- � TEMPORARILY ��� �� IMPACTED WETLAND 1 Y, j 0 IMPACTED STREAM 1 j� (APPROX. 12,420.9 SQ.FT.) (APPROX. 219 FT.) + LEGEND EXTENTS OF TEMPORARY IMPOUNDMENT EXISTING STREAM WETLANDS PROJECT BOUNDARY IMPACTED WETLAND AREA �-0000 0000 o� o� PROJECT BOUNDARY 0000 0001, _ (APPROX. 3.09 ACRES) 0000o _ rJ + VVA 5 0 0 " 10� F P1\6226 04 0gM1 ng\Prqt@cft\20u\8=61400D4 D- rix rt"-w*\SUffnwat r PlonrJng\end."-f --4& -ffioddwro - Figure 01 - May. 18. Zoos 4°s4pm - jaekbNl DUKE E E Y CLIENT: DUKE ENERGY - CAROLINAS DWN BY: JMB PROJECT DAN RIVER STEAM STATION 48 -INCH INLET AREA CLEAN-UP DATE: JULY 31, 2014 CHK'DBY: XXX PROJECT NO: 6226-14-0004 DATUM: NAD99 AMEC Environment &Infrastructure 2801 YORKMONT ROAD, SUITE 100 CHARLOTTE, NC 28208 PHONE 704-357-8600, FAX 704-357-8638 LICENSURE: NC ENG: F-1253 NC GEOLOGY: C-247 _ � w € '� ���- ' TITLE PLAN VIEW REV. NO.: A PROJECTION: UTM Zone 0 FIGURE No. FIGURE 01 SCALE: 1" = 50' P1\6226 04 0gM1 ng\Prqt@cft\20u\8=61400D4 D- rix rt"-w*\SUffnwat r PlonrJng\end."-f --4& -ffioddwro - Figure 01 - May. 18. Zoos 4°s4pm - jaekbNl P1\U26 04 0gM1 ng\Prqt@eW\20u\ena14aoo4 D- 10— mon-\SUrInwat r PlonrJng\WotlondJ"—f --4& —moddwro — Rpre 02 — May. 18. 2015 12.39prn — Ian,beN 530 525 Ezdae strAarp Centerline 520 515 510 0 20 40 10 60 80 SECTION A -A 0 10 20 FT 10 HORIZONTAL SCALE 100 0 10 VERTICAL SCALE 120 20 FT 140 DUISEDATUM: E E Y CLIENT: DUKE ENERGY - CAROLINAS DWN BY: JMB PROJECT DAN RIVER STEAM STATION 48 -INCH INLET AREA CLEAN-UP DATE: JULY 31, 2014 CHK'DBY: XXX PROJECT NO: 6226-14-0004 NAD99 AMEC Environment &Infrastructure 2801 YORKMONT ROAD, SUITE 100 CHARLOTTE, NC 28208 PHONE 704-357-8600, FAX 704-357-8638 LICENSURE: NC ENG: F-1253 NC GEOLOGY: C-247 � p ���- TITLE CROSS - SECTION VIEW REV. NO.: A PROJECTION: UTM Zone 0 FIGURE No. FIGURE 02 SCALE: P1\U26 04 0gM1 ng\Prqt@eW\20u\ena14aoo4 D- 10— mon-\SUrInwat r PlonrJng\WotlondJ"—f --4& —moddwro — Rpre 02 — May. 18. 2015 12.39prn — Ian,beN 0 E F-4 2 3 4 5 6 7 8 9 FIG. A REV. 0 INCH DUCTILE IRON PIPE DISCHARGES TO O P / / O s SERVICE WATER SETTLING POND AT v FORMER INTAKE. �� f V - 4® (I A O + \a $a ®®® \ 6-® v v\ yl V X/ X \ \ \ V � \90 / fX \ - F /v Pe \' � +� Ar 4177 \I , , I I + -------------- r � f �UO \\� - 6 -INCH DIAMETER HDPE y \ _ �— \ \ SDR -21 DISCHARGE PIPE � TIE-IN TO EXISTING 6 -INCH DUCTILE IRON PIPE WITH OR HDPE BOOT. TEE B� yy❑ _\ — — GODWIN 8 -INCH TEMPORARY SINGLE LANE ROAD RAMP (12 -FT WIDE) V \ \ NOTE: FOR LARGER VEHICLE TRAFFIC USE STONE PIPE RAMP CROSSING 6 -INCH DIAMETER HDPE � /SDR -21 DISCHARGE PIPE INSTALLED AT GRADE SERVICE WATER SETTLING POND ( I J 7 \ \ f \ I I I I \ \ DISCHARGES TO DAN \. ��� / \ �' / o \ RIVER UPSTREAM OF / \ POWERHOUSE DAM rV A \ �.-. 0 0 f ❑ I 8 -INCH DIAMETER HDPE + 'GODWIN CD -150 DIESEL � ;SDR -21 SUCTION PIPE � �/ �=� s INSTALLED AT GRADE PUMP \ INVERT AT INTAKE: 509.0 PUMP OFF - 510.5 r PUMP ON - 511.6 � \ El \ AV r / v CZ� / \ _ TITLE STORMWATER DIVERSION \\i ��y'❑ 11 \ f� f m 48 INCH INLET AREA CLEAN UP AMEC Environment& DAN RIVER N \ o v v v __❑ ,� -\ A y A 77— Infrastructure, Inc. STEAM S TATI 0 \\ — -�- A f v \ v - _ ❑// ,y ,110, F� 2801YORKMONTROAD, SUITE 100 ROCKINGHAM COUNTY, NORTH CAROLINA INCHES 1 2 3 ITENTHS 10 20 \ \ \ \ \ \\ \�\/�\ CHARLOTTE, NC 28208 \ \ \ \ \ \ \ /v \\\�_ \ / TEL: (704) 357-8600 \ % 525 -\ \ \ ` \'= \� ( /_' \\ �\ FAX: (704) 357-8638 FOR / ` \ \ LICENSURE: � NC ENG: F-1253 ISSUED FOR PERMITTING - NOT RELEASED FOR CONSTRUCTION —� 23 -\ �\ A� A / NC GEOLOGY: C-247 SEAL SCALE: AS SHOWN DES: JMB UKE SS \ � ii ��,- ��--�-----� -__-� � � � � �\ � � � DWG TYPE: DWG DFTR: ---------- JOB NO: 6226-14-0004 CHKD: ENEK%7 T \_ \ i [EATE:MARCH 23, 2015 ENGR: JMB p\\\ \ _�--vim ' \ FILENAME: APPD: REV DATE JOB NO. PROJECT TYPE DES DFTR CHKD ENGRI APPD DESCRIPTION DWG SIZE DRAWING NO. REVISION 0 03/23/15 6226-14-0004 TORMWATER REROUTE JMB SS JMB JMB INITIAL ISSUE ARCH FIG. A O 24.0"x35.5" 0 4 5 6 7 8 9 10 M M C) Permit No. (to be provided by DEMLR) State of North Carolina Department of Environment and Natural Resources Division of Energy, Mineral and Land Resources STORMWATER MANAGEMENT PERMIT APPLICATION FORM LOW DENSITY SUPPLEMENT This four. may be photocopied for use as an original A low density project is one that meets the appropriate- criteria for built upon area and transports stormwater runoff primarily through vegetated conveyances. Low density projects should not have a discrete stormwater collection system as defined. by 15A NCAC 2H ,1002(18). Low density requirements and density factors call be found in Session Law 2008-211, 15.A. NCAC 2H .1000, Session Law 2006-216 and the State of North Carolina Stornnwater Best Managcment Practice Manual.. Curb and gutter systems are allowed provided they meet the requirements in 15A NCAC 2H .1008(g). 1. PROJECT INFORMATION Project Name : Duke Dan River Project - 36 -inch Culvert Plug and 48 -inch Inlet Area Clean -Up Contact Persozn: Joshua Bell. P.E. Phone plumber: ( 704 )517-2618 Number of Lots:N/A Allowable Built Upon Area (BUA) Per Lot*:N/A Number of Dwelling Units Per Acre's*:NIA Low Density Development (check one): ❑ without curb & gutter ❑ with curb & gutter, outlets to (clack orae): ❑ Swales ❑ Vegetated Area *If lot sixes are not uniform, attach a table indicating the number of lots, lot sizes and allowable built upon area for each lot. The attachment must include the project name, please, page numbers and provide area subtotals and totals. BUA shall be shown in units of square feet. **(Phase .11 Post -Construction [non-SAl only) I1. BUILT UPON AREA Refer to DEMLR's forms and applications website for specific language that incest be recorded in the deed restrictions for all subdivided projects. (httl):Ilpoital.ncdenr.or /g webllrlstate-stoiianwater-for[ns_does) Coinpletc the following calculation in the space provided below wlncre: • SA Site Area - the total project area above Mean High Water. ■ DF Density Factor - the appropriate percent built upon area divided by 100. • RA Road Area - the total impervious surface occupied by roadways, • OA Other Area - the total area of impervious surfaces such as clubhouses, tennis courts,, sidewalks, etc. • No. of Lots - the total number of lots in the subdivision. • BUA per Lot - the computed allowable built upon area for each lot including driveways and impervious surfaces located between the front lot line and the edge of pavement, • Total allowable lot BUA - the computed allowable built upon area for all lots combined. • Total BUA from lot listing - the sum of built upon arca allocated for each lot on the list of non-uniform lots. I;ornn SW401-Low Density-Rev.3-211.0109 Page T of 4 Calculation: For uniform lot sues: (SA: ftp x DF: ) SRA: ft') (QA: ftz) = BUA per Lot = ft, (No of Lots: ) For non-uniform lot sues: a. (SA, f12 x DF, } — (RA: ftp} — (CSA: ft2) = Total allowable lot BUA ft2 b. Total BUIL from lot listilag; sf b must be:5 a III. DESIGA ! N N 01MATION Con pletc the fallowing table. If additional space is needed the information should be provided in the same format as Table 1 and attached to this fond. Rainfall intensity data can be found iia Appendix 8.03 of the State of North Carolina Erasion and Sedfineut Control Planning azld Desigi7 Manual or at http:1111d se.nws.no aa, gov/lidsc/pfd sl Table 1. Swale desim information based on the 1.0 -year storm, Swale No. Drainage. Area (ac) Tinpervious. Arca ac Grassed. Area (ac) C Q (ds) Slope 0/o) Vallow s V,ctual fps) Flow ` Depth ft 1 2 3 4 5 6 7 8 9 10 11 1.2 13 14 15 16 17 18 19 20 Fonn SW401 -Low Density-Rev.3-2/] 0109 Page 2 of 4 IV. REQUIRED ITEMS CHECKLIST The following cheeldist outlines design requirements per the North Carolina Administrative Code Section 15A NCAC 2H .1000, NCDEN R BMP Manual (2007), Session Law 2006-246, and Session Law 2008-211. Please indicate the page or plan sheet numbers where the supporting documentation can be found. An incomplete submittal package will result in a request for additional information. This will delay final review and approval of the project. Initial in the space provided to indicate that the- following requirements have been tinct and supporting documentation is provided as necessary. If the applicant has designated an agent on the Stonnwater Management Permit Application Fonn, the agent may initial below. If any item is not met, then_. justification must be attached. Only complete items n through p for projects with curb outlets. Page/Plan Initials Sheet No. a. t For projects in the 20 coastal counties: Per NCAC 2II.1005, a 50 foot wide vegetative buffer is provided adjacent to surface waters. For :Rcdcvelopment projects, a 30' wide vegetative buffer adjacent surface waters is provided. b. t For HQW or ORW projects outside the 20 coastal. counties: A 30 foot wide vegetative buffer is provided adjacent to surface waters. C. t For Phase Il Post -Construction projects: All built upon arca is located at least 30 feet I andward of all perennial and intennittent surface waters, d. Deed restriction language as required on form SWU-101 shall be recorded as a restrictive covenant. A copy of the recorded document shall be provided to DWQ within 30 days of platting and prior to the sale of any lots. e. Built upon arca calculations are provided. for the overall project and all lots. f Project conforms to low density requirements within the ORW AEC. (if applicable per 15A NCAC 2Il .1007) g. Side slopes of swales are no steeper than 3:1; or no steeper than S: ]for curb outlet stivales. h. Longitudinal slope of swales is no greater than 5%; for non -curb outlet projects, calculations for shear stress and velocity are provided if slope is greater than 5%. i. At a niiiiiznum, swales are designed to carry the 10 year storm velocity at a non-erosive rate. D"Is i� j. Swales discharging to wetlands are designed to flow into and through the wetlands at a non- erosive velocity (for this flow requirement into wetlands, non-erosive is velocity :5 2 ft/s). k. Swale detail and pennnanent vegetation is specified on the plans. 1. Swale detail provided on plans; includes grass type(s) for permanent vegetative cover. M. Swales are located in recorded drainage easements. n. 'H' Length of swale or vegetated area is at least 100 feet for each curb outlet. o.tt The system tabes into account the run-off at ultimate built -out potential from all surfaces draining to the system (delineate drainage area for each swale). p tt Curb outlets direct flow to a swale or vegetated area. Projects in the Neuse, Tar -Pamlico, Catawba .River basins, and Randleman Malec may require additional buffers. It Only complete these items for projects with curb outlets. Form SW401-Low Density-Rev.3-2110109 Page 3 of 4 V. SWALE SYSTEM MAINTENANCE REQUIREMENTS 1. Mowing will be aecomplished as needed according to the season, Crass height will not exceed six inches at any tine; and grass will not be mowed too close to the ground or "scalped". 2. Swales will be inspected monthly or after every runoff producing rainfall event for sediment build-up, erosion, and track accumulation. 3. Accumulated sediment and trash will be removed as necessary, Swales will be reseeded or sodded following sediment removal. 4. Eroded areas of the swales will be repaired and reseeded. Swales will be revegetated as needed and in a timely manner based on the monthly inspections. Side slopes must be maintained at the permitted slope. 5. Catch basins, curb cuts, velocity reduction devices, and piping will be inspected monthly or after every significant runoff producing rainfall event. Trash and debris will be cleared away from &),rates, curb cuts, velocity reduction devices and piping. G. Swales will not be altered, piped, or filled in without approval from NCDENR. Division of Energy, Mineral and Land Resources. I acknowledge and agree by my signature below that I ann responsible for the performance of the six niaintenance procedures listed above. I agree to notify DEMLR of atny problems with the system or prior to any changes to the system or responsible party. Print Name and Title:1c% spa. %11, PE Address:2801 Yor.Ri�4t9�0, Charlotte, NC 28208 Phone: 7045 L73 659 A I Date:, i { Signature, Nate: The gaily r h, of he u homeowners asrncicrtionunless morelesore than 50%of the Lots have been sold and ca resident of the s�l�Al h.Xenamed line president. I, a Notary Public for the State of _, County of do hereby certify that personally appeared before me flys _ day of ,.and acknowledge the due execution of the forgoing swale maintenance requirements. Witness ray hand and official seat, Notary signature SEAL My commission Folin SW401-Low Density-Rev.3-2110109 Page 4 of 4 Attachment A This project is to provide for the clean-up of ash and the temporary impoundment of storm water at the grouted 48 inch reinforced concrete pipe that drains a n 18.6 acre drainage area just upstream of the existing Primary Ash Basin at Dan River Steam Station in Eden, North Carolina. The impacts to the stream include the temporary inundation of the wetlands following storm events and the clean-up of coal combustion products released into the area during the downstream fail ure of the 48-inch pipe. Calculations indicate that the wetland area can store the 25 -year storm event up to elevation 525.0 without discharge. Pumping capacity currently provided allows for the temporarily impounded water to be drawn back down within 72 hours of the storm event. Pumped flows will be discharged to the Service Water Settling Pond by way of existing piping to a proposed new storm water outfall . U.S. Fish & Wildlife Service U lIfe IPaC Trust Resource Report US Fish & Wildlife Service IPaC Trust Resource Report Project Description NAI\iE My project PROJECT CODE 4GSTK-LL3M5-FX5EH-P6RUP-Q7CRHM LOCATION Rockingham County, North Carolina DESCRIPTION No description provided 4GSTK-LL3M5-FX5EH-P6RUP-Q7CRHM w� I;� III irA �r1{ sy i l f All am b y IKem-anville c.0 I LF OR I! Irb. r r.,r,trnAvn Ha aler>4 GreensboroGibsonville i „i RI" -:r FII.II� I,llll'2`"t�i1411 U.S. Fish & Wildlife Contact Information Species in this report are managed by: Raleigh Ecological Services Field Office Post Office Box 33726 Raleigh, NC 27636-3726 (919) 856-4520 Endangered Species Proposed, candidate, threatened, and endangered species that are managed by the Endangered Species Program and should be considered as part of an effect analysis for this project. Clams James Spinymussel Pleurobema collina Endangered CRITICAL HABITAT No critical habitat has been designated for this species. https://ecos.fws.gov/speciesProfile/profi le/speciesProfi le. action ?spcode=F025 05/19/2015 10:59 IPaC Information for Planning and Conservation Page 2 Version 2.0.18 IPaC Trust Resource Report Flowering Plants Smooth Coneflowef lower laevigata CRITICAL HABITAT No critical habitat has been designated for this species. 4GSTK-LL3M5-FX5EH-PERU P-Q7C RHM https://ecos.fws.gov/speciesProfile/profi le/speciesProfi le. action?spcode=Q293 Critical Habitats Endangered Potential effects to critical habitat(s) within the project area must be analyzed along with the endangered species themselves. There is no critical habitat within this project area 05/19/2015 10:59 IPaC Information for Planning and Conservation Page 3 Version 2.0.18 IPaC Trust Resource Report 4GSTK-LL3M5-FX5EH-P6RUP-Q7CRHM Migratory Birds Birds are protected by the Migratory Bird Treaty Act and the Bald and Golden Eagle Protection Act. Any activity which results in the take of migratory birds or eagles is prohibited unless authorized by the U.S. Fish and Wildlife Service (1). There are no provisions for allowing the take of migratory birds that are unintentionally killed or injured. You are responsible for complying with the appropriate regulations for the protection of birds as part of this project. This involves analyzing potential impacts and implementing appropriate conservation measures for all project activities. American Bittern Botaurus lentiginosus Bird of conservation concern Season: Wintering https:Hecos.fws.gov/speciesProfile/ rop file/speciesProfile.action?spcode=BOF3 Bald Eagle Haliaeetus leucocephalus Bird of conservation concern Year-round https://ecos.fws.gov/speciesProfile/profi le/speciesProfi le. action?spcode=B008 Blue -winged Warbler Vermivora pinus Bird of conservation concern Season: Breeding https://ecos.fws.gov/speciesProfile/profi le/speciesProfi le. action?spcode=BOJY Brown -headed Nuthatch Sitta pusilla Bird of conservation concern Year-round https://ecos.fws.gov/speciesProfile/profile/speciesProfile.action?spcode=B017 Chuck -wills -widow Caprimulgus carolinensis Bird of conservation concern Season: Breeding https:Hecos.fws.gov/speciesProfile/profile/speciesProfi le. action ?spcode=BOLA Fox Sparrow Passerella iliaca Bird of conservation concern Season: Wintering https://ecos.fws.gov/speciesProfile/profile/speciesProfile.action?spcode=BONE Kentucky/ Warbler Oporornis formosus Bird of conservation concern Season: Breeding https://ecos.fws.gov/speciesProfile/profile/speciesProfile. action?spcode=B01 N Least Bittern Ixobrychus exilis Bird of conservation concern Season: Breeding https:Hecos.fws.gov/speciesProfile/profi le/speciesProfi le. action ?spcode=BOJ W Loggerhead Shrike Lanius ludovicianus Bird of conservation concern Year-round https://ecos.fws.gov/speciesProfile/profi le/speciesProfi le. action?spcode=BOFY Pied -billed Grebe Podilymbus podiceps Bird of conservation concern Year-round https://ecos.fws.gov/speciesProfile/profi le/speciesProfi le. action?spcode=BOJQ 05/19/2015 10:59 IPaC Information for Planning and Conservation y Version 2.0.18 IPaC Trust Resource Report 4GSTK-LL3M5-FX5EH-PERU P-Q7C RHM Prairie Warbler Dendroica discolor Bird of conservation concern Season: Breeding https://ecos.fws.g ov/species Prof i le/prof ile/speci es Prof i le. action ?spcode= BO K4 Prothonotary Warbler Protonotaria citrea Bird of conservation concern Season: Breeding https://ecos.fws.g ov/species Prof i le/prof ile/speci es Prof i le. action ?spcode= BO IJ Red-headed Woodpecker Melanerpes erythrocephalus Bird of conservation concern Year-round https:Hecos.fws.gov/speciesProfile/profile/speciesProfile.action?spcode=BOHR Rusty Blackbird Euphagus carolinus Bird of conservation concern Season: Wintering https:Hecos.fws.gov/speciesProfile/ row/speciesProfile.action?spcode=BOJI Wood Thrush Hylocichla mustelina Bird of conservation concern Season: Breeding https://ecos.fws.gov/speciesProfile/profile/speciesProfile.action?spcode=BOIB Worm Eating Warbler Helmitheros vermivorum Bird of conservation concern Season: Breeding https:Hecos.fws.gov/speciesProfile/profile/speciesProfile.action?spcode=BOI I 05/19/2015 10:59 IPaC Information for Planning and Conservation Page 5 Version 2.0.18 IFN Rwry EDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor Steve Cahoon Duke Energy Carolinas, LLC 410 S. Wilmington St. Raleigh, NC 27601 Division of Mitigation Services May 26, 2015 Project: Dan River Steam Station 48 -inch inlet area clean-up Donald R. van der Vaart Secretary Expiration of Acceptance: November 26, 2015 County: Rockingham The purpose of this letter is to notify you that the NCDENR Division of Mitigation Services (DMS) is willing to accept payment for compensatory mitigation for impacts associated with the above referenced project as indicated in the table below. Please note that this decision does not assure that participation in the DMS in -lieu fee mitigation program will be approved by the permit issuing agencies as mitigation for project impacts. It is the responsibility of the applicant to contact permitting agencies to determine if payment to the DMS will be approved. You must also comply with all other state, federal or local government permits, regulations or authorizations associated with the proposed activity including G.S. § 143-214.11. This acceptance is valid for six months from the date of this letter and is not transferable. If we have not received a copy of the issued 404 Permit/401 Certification/CAMA permit within this time frame, this acceptance will expire. It is the applicant's responsibility to send copies of the permits to DMS. Once DMS receives a copy of the permit(s) an invoice will be issued based on the required mitigation in that permit and payment must be made prior to conducting the authorized work. The amount of the in -lieu fee to be paid by an applicant is calculated based upon the Fee Schedule and policies listed at www.nceep.net. Based on the information supplied by you in your request to use the DMS, the impacts that may require compensatory mitigation are summarized in the following table. The amount of mitigation required and assigned to DMS for this impact is determined by permitting agencies and may exceed the impact amounts shown below. Impact River Basin CU Stream (feet) Wetlands (acres) Buffer I Buffer II Location (Sq. Ft.) (Sq. Ft.) Cold Cool Warm Riparian Non -Riparian Coastal Marsh Roanoke 03010103 0 0 513 0 0.505 0 0 0 Upon receipt of payment, DMS will take responsibility for providing the compensatory mitigation. The mitigation will be performed in accordance with the In -Lieu Fee Program instrument dated July 28, 2010. Thank you for your interest in the DMS in -lieu fee mitigation program. If you have any questions or need additional information, please contact Kelly Williams at (919) 707-8915. Sincerely, James. Stanfill Asset Management Supervisor cc: David Bailey, USACE-Raleigh Richard Harmon, agent 1652 Mail Service Center, Raleigh, North Carolina 27699-1652 Phone: 919-707-89761 Internet: www.nceep.net An Equal Opportunity �. Affirmative Action Employer — Made in part from recycled paper U.1. AMV1Y UUKYS UY EINGENELKS WILMINGTON DISTRICT Acroa-, la. 2SAW-:4914-01477 County: macKin,nunl U.s.G.S. quad: 1NC-5i7U 1 iiLA51 LUEN GENERAL PERMIT (REGIONAL AND NATIONWIDE) VERIFICATION Pcrmi[lcc: liLLKc „erEy Pro£ress Abent: AMSC Environment & Infrastructure Inc. attti: Steve Cahoon attn: Josh Bell, P.E. Aaara.s: to 0 S Wilm .,gton Street Address: 2801 Yorkmont Road Suite 100 R..Ie.,h, NC.37601 Charlotte, NC 28208 ti:Zc (uU-e7') 1.151 Nearest Town LLden NUNPIVA U 1- to U..n Kivca River Basin u„t,er Dan. Nortn Car.,l;..a.yir,i;.;a. U6G6 r1U17 1561u11115 Coordinates .55.491704 N -'19.11bi31 W Leeot:v-. ucnvri,,tivT,: t nu 4,: o;act L loc..tcil Ft tl;c Uakc L11crrr DailK,:,a ltc:,., ,tat;ui-. an the —. no.-tl:est 3:TI ac ortl:c asGnL eo41.,�n nW3m. ,-vwiR1.,[cl U.9 ..—,ile northeast of the existing ower generation glant. LJc.oPiyt�o,-. of pra�ects area and activity: The �,ro,.osed .,ro;ect includes a permanent discharge of tell material into O.00I acre of wetlands and 4 linear feet _(8_sq. _ft.) of streams, resulting in theyermanent conversion of 0.097 acre of wetlands and 61 linear feet (0.003 acre) of stream_ to open waters in order to close a 36 inch corrugated metal pipe that flows under an existing coal r.,n 6w.:n. Applicable Law: ® Section 404 (Clean Water Act, 33 USC 1344) ❑ Section 10 (Rivers and Harbors Act, 33 USC 403) Authorization: Regional General Permit Number or Nationwide rermi[ number: nWr ja,v,inor „ischarges. 5CC Al !AMICI) ICGr .,, 1VWY UZ1vZKAL KZiyJD1vAL A1V.0 ")I-CC1AL CalvL1Lllalva Your work is authorized by the above referenced hermit provided it is accomplished in strict accordance with the attached conditions and your submitted application and attached information dated 7/3/2014 (received 71712014) and revised information dated 9/12/2014 (received 9115/2014). Any violation of the attached conditions or deviation from your submitted plans may subject the permittee to a stol, work order, a restoration order, a Class I administrative penalty, and/or appropriate legal action. This verification will remain valid until the expiration date identified below unless the nationwide authorization is modified, suspended or revoked. If, prior to the expiration date identified below, the nationwide permit authorization is reissued and/or modified, this verification will remain valid until the expiration date identified below, provided it complies with all requirements of the modified nationwide permit. If the naiionwide permit authorization expires or is suspended, revoked, or is modified, such that the activity would no longer comply with the terms and conditions of the nationwide permit, activities which have commenced (i.e., are under construction) or are under contract to commence in reliance upon the nationwide permit, will remain authorized provided the aciivity is completed within twelve monihs of the date of the nationwide permit's expiration, modification or revocation, unless discretionary authority has been exercised on a case-by-case basis to modify, suspend or revoke the authorization. Activities subject to Section ziUzi (as indicaletl aoove) may also require an intlivitluat .>eciion yv, water yuatity CerThicadon. it ou should contact the tvC vivision of water yuatity tietepnone y ty-a'ur-'o [1'u) to determine section 40t requirements. ror activities occurring within the twenty coastal evn..l:c., 3..njev[ iv .-c5nlAo.. :; :avP in.. Co. ma Aaeu Act kCAMA), prior to oeginning worK you mus[ contact Lne 1V.C. or 1113 1Jc1r.F[PRe777[ Ot the A.mi., Yc.-itivatioia doe. .-..,t rclicvc tnc Permittee of the respow�.nii ty to obtain any othrr icyulica ucdc.wl, )tale o.- lveW uPPPa r W I�1PcP117:t�. If there are any questions resardins this verification, any of the conditions of the Permit, or the Corps of Enbineers regulatory Probram, Please contact David Bailcy at 910-251-4469 or David.E.Bailey2fo.usace.army.mil. Corps Regulatory Official: _ _ Date: 'v9/z..9/c014 v"tc of Verification: 03/18/2017 Copy furnished: Sue Homewood, NCDENR-DWR, 585 Waughtown Street, Winston-Salem, NC 27101 Special Conditions: 1) The ponding .,ester from the authux i ed inundation must be re-routed as shown and described in r igure 03 and Fi,ure 04 included in ,,our submitted re, ised informatiuu dated 9/12/2014 (received 911512014). 2) Please note that future pha3es of pipe closures and other coal ash basin cleanup activities at the Duke Ener,, Dan Ri, er Steam Station may be „sidered part of a single and complete project, and impacts may be consideree cumulative, with rest,ect to comt.ensato.T mitigation and Nationwide Perri -tit thresholds, with impacts permitted during earlier phases autharized and documented under Action ID: SAW -2014-01477. 3) Given that ine auinorized imt.acts will be in glace for se, eral y cars without an enforceable timeline or restoration method_ they are considered permanent with respect to impact type anti potentially for future phase compensatory mitigation requirements. 4) riease notz that this Nationwide Permit authorization expires on 371872017, aL.d yuu must request reauthorization for pumping/draw-down activities as permitted here -in if t.re-existin., conditions are not restored in the subject wetland/stream complex by that date. Corps Regulatory Official: % vate: 95/zyiLV1z; David -. Bailey t;xpiration Late or ver:r:r,z;t;o..: 9.3gatLlil l Determination of Jtlrisdktivn: A. ❑ Based on preliminary information, there appear to be waters of the US including wetlands within the above described project area. This preliminary determination is not an appealable action under the Regulatory Program Administrative Appeal rrocess ( Reference 33 CFR Par! 331). B. ❑ There are Navigable Waters of the united 5lales within the aoove tlescribetl project area suoject to tile permit requirements of Seciion 10 of the Rivers and Harbors ftCL anti section 44 of the Clean water r.cr. unless mere is a change in the taw or our published regulations, this determination may be relied upon for a period not to exceed five years from the date of this notification. C. ® There are waters o, the us antl,or weuanm witnin ifie aoove Rescrimtl project area suoject to the permit requirements of Section 4'vr+ of the Clean w ater r.ct k%wr.)V,a usC § unless mere is a change in the taw or our pumisned regulations, this determination may be relied upon for a period not to exceed live years trom the bate of Lnis notincation. u. ❑ f he jurisaictional areas witnin me aoove desc-:oca ^l meet ..+-e.+ nr..� peen .8e.-.t:t:ca -_.-.aeP a Y.c-.vee vette.-.. rte@moo efcl'c.-.ce jurisakdonai determination issues . Actio.—. 1L: 5AW- 111. a.to cnli'.Bais ic,.tare. , itn UiU.2n..,- l3, •n write- unR ,w,e[laiiiis as del6;e1 in the l`J2i i w.;tla„d acll;.ewtle+: +'...all�+a .+e8 lh:vnle a c ivnul au lcincnta. i lie �rutc(•a iRClnilC uu ninaRlcti tnll)tltar lI1 to 1)un Kivu - a Ke1�L';-cl 1'0,.'..,ne.'t wutt:� Krw .;n.en no,—,� c�:.-�t-tl to tnt: leu,. Ki;�r u r.-at�itier...il lvari able Wate.-- u..3 unutt:n -ctl�-.dam. 0E. detcl :..rt'.yo 13 t)V lllarii] L. 15i.i1cV IUTACN;) on 8/1 312 0 1 4. KCnlunKa: E. Attention USDA Program rarticipants This delineation/determination has been conducted to identify the limits of Corps' Clean Water Act jurisdiction for the particular site identified in this request. The delineation/determination may not be valid for the wetland conservation provisions of the Food Security Act of 1985. If you or your tenant are USDA Program paRicipanw, or anticipate participation in USDA programs, you should request a certified wetland determination from the local office of the Natural Resources Conservation Service, prior to starting work. F. A1.i.eals Info, mations (This information applies only to approved jurisdictional determinations as indicated in B and C above). This correspondence constitutes an approved jurisdictional determination for Ine aoove descrioed site. ii you ooject to finis determination, you may request an administrative appeal under Corps regulations at» Crm ran .» i. meioses you will !ma a Notification of Appeal Process (Nr.r) fact sheet and request for appeal (mrr►) Corm. ii you request to appeal tnis determination you must submit a completed fort. form to the following address: 115 A,a..y Cv,Ns or 5vu111 Aitv-.-,t-Ic L:r,�ivN ALL.-': Jure.. Steele, 1ZcriCy. ❑tLiw� So 1"ol9ytn Siicc[ 5w, Kpp,.. laMl.) A[lant.., tievaS.G .0.0.i-bbai Phone: (404) 562-5137 In order for an mri. to be accepted by the Corps, the Corps must determine ulat it is complete, inat it meets the criteria tar appeal under 33 CFm pal L.%) f .a, and that it has been received vy ule Livision Vince witnin o'u days of the date of the ivttr. 5nouia you decide to submit an RFA form, it must be received at the above a'udress oy ><vz5twfrr. to M-.. KVA Lvarm to the Othee :t you do .tot onjcct tv the determination in this eorr, syondenee.— Cotes Resulatory Official:_.— fl.-.sib Date of JD: 9/A9/20t4 expiration Late o1 jL: yrcy/Luf y 1 Me L,.rt..et :- ee ;IieB to tnv n:,,nest terel of vj ljvrt to trc Fza%u. 1 o neip us cnswc .,� uon.tirse to no au, ,,lease ee...f,lete au' ci3.rtamxi bur rey e..ltoe ui I.tt,,:ll.e_I�tutP. Y.u'uCCaii. rcY •cOi���. 1v0TIP.LiCA1 tviv yr AUiviiniSiimA itIVE ArrhAL Ort IONS AND PROCESS AND REgUEST FOR APPEAL Applicant: Duke Energy Pra ress File Number: SAW-2013-01477 ate: 0912912014 Auacnea is: Sec Jcction nclo�r -07 INITIAL PROFFERED PERMIT Standard Permit or Letter of ermission A U PROFFERED PERMIT Standard Permit or Letter of ermission rs jJ PERMIT DENIAL C APPROVED JURISDICTIONAL DETERMINATION D LJ PRELIMINARY JURISDICTIONAL DETERMINA I Ion n SECTtOty t - t he following inemilies your rights ana opt,o-s .-egarDi.,, u;-, uti; ,;,,t.-..[ :V at puna of inc t)vTc NDDitiornat :ntv....atio;. ;-,y po TvErta at OF rttp:a.—.,Y..;sace.aimr.mil/Missions/CivilWarks/Regulato,yProeramandPermits.asvx or the Corps regulations at 33 CFR Part 331._ A: INITIAL PROFFEREL rEntnut : r ou may accept or o,oject to the permit • ACCIMP I: t[ yon -ovoi GD .. St.iA.r0 Yc.....t you mar sign the permit document and return it to the district ensineer for final authorization. If you received a Letter of Permission (LOP), you may accept the LOP and your work is authorized. Your signature on the Standard Permit or acceptance of the LOP means that you accept the permit in its entirety_ and waive all rights to appeal the permi[, including its terms and conditions_ and approved jurisDictionat neterminations associates witn Lne permit. OBJECT: If you object to the permit (Standard or LOP) because of certain terms and conditions therein, you may request that the permit be modified accordingly. You must complete Section a of this form and return the form to the District engineer. r our objections must ue receive0 Dy the District engineer witnin 6v says of n:e DuTe forfeit your right To appeal me rernt:[ ;., n:� ierirv. Upoa, rc�Gipt of roet.-totter; the district engineer will evaluate your ob�cct�ons and may: (a) modify the permit to address all of your concerns, (b) modify the permit to address some of your objections, or (c) not modify the permit having determined that the permit should be issued as previously written. After evaluating your objections, the district engineer will send you a proffered permit for your reconsideration, as inuicatea in Section v belma. B: PROFFERED PERMIT: You may accept or appeal the permit • tiCCr r) : if you receiveu a stanaata rermit, you may s:g... Lne t.e,ltl'.t Dee!!.,,v„[ w.-.D rG[.. m h to Inc Dist.ME G.-.r,1,.Ge. ro.- final �eu.or:�w[ion. a yoe .-ccci.t:U u Lettor of Permission (LOP), you may accept the LOP and your work is authorized. Your sir,nature on the Standard Permit or acceptance of the LOP means that you accept the permit in its entirety, and waive all rights to appeal the permit, including its terms and conditions, and approved jurisdictional determinations associated with the permit. ■ APPEAL: Ifyou choose to decline the proffered permit (Standard or LOP) because of certain terms and conditions therein, you may appeal the declined permit under the Corps of Engineers Administrative Appeal Process by completing Section 11 of this form and sending the form to the division engineer. This form musi be received by t1Te division engineer within 50 Days Of the date of this notice. C: PERMIT DENIAL: You may appeal the denial of a permit under the Corps of Engineers Administrative Appeal Process by completing Section II of this form and sending the form to the division engineer. This form must be received by the division engineer within 60 days of the date Of this notice. L: ArrJKU V :u J uxiauiC i TONAL uETERMINATION: You may acceptor appeal the approved JD or provide new information. • ACCEFT : x ou do not neer to notity me Corps to accept an approve0 iii. raiture To notiry Lne Ce.—Y, Biu::. 60 air . of [nG Date o[ tn:s notice e..!!, lr_[yon uGCGpL II.c wpp.o.ca JLJ :n :[a rntiroty; and waive all rishts to appeal the approved JD. APPEAL: If you disagree with the approved JD, you may appeal the approved JD under the Corps of r.ngineers Administrative Appeal rrocess by completing Section it minis Corm ana sensing tile form to me District engineer. t na far.. MUST fie receive0 Dy n.e o:vs:e.-. en,:,-,oe.- w;u.:e 50 Dura "T-160 ar.1c of MIS ..v[:ee. 1',: rKh]U11V11rVAKY ./UK15111C,11VlYAL 11b I K1V111VA 11VA: yva (Iv .imi nvvEl to ic,Fvnd to tro Corps acrarding the iL). inv. 1j.c1.1`R'7-.u.—y iii :s not appealable. Ifyou wish, you may request an approved JD (which may be appealed), by contacting; the Corps district for further instruction. Also you may provide new information for further consideration by the Corps to reevaluate the JD. SECTION lI - REQUEST FOR AP-FAL, orv15iEC. i IGtv5 10 Ary INN I I/Al, PROrrEKGu rr-Rivii I IILZA50Nl VOK Arl'ftL vK QbitC 1 IONS: [Describe your reasons for appealing; the decision or your objections to an initial proff red permit in clear concise statements. You may attach additional information to this form to clarify where your reasons or objections are addressed in the administrative record.) ADDITIONAL INFORMATION: The appeal is limited to a review o1 Lne administrative record, ute Corps memorandum ror me record of the appeal conference or mee[ing, and any suppleme.-.tz1 :ego.- ut:o.. tl,wt u.v Tc icrr otiicc. ni-- avivrrrlimca is ..ccaca to ctariry ute..d-:.-.i.r...t:.e aepo,d. Neu ,icr inc uppcn..nt nor the Corps may add new information or analyses to the record. 11v,.e.er, yoti may provide additional information to clarify the location of information that is already in the administrative record. POINT OF CONTAC F FOR QUESTIONS OR INFORMATION: If you have questions regarding this decision andior the 1r you omy nave quest.p,., ,C57-1"15 111c Wppc..l pivcc33 you .....y appeal process you may contact: also cv;-.ti.ct: 11.,,tr.ct 1, rlr,;uccr, w.letingtvn xcgulator yy Division Mr. Jason Steele, Administrative Appeal Review Officer .=Eln:l1µ;;0 L. 13AIC,7 CESAD-PDO xu[z:gfi tcc ulN[o., r ivill V111c.. U.S. Army Corps of engineers, 50utl1 Atlantic Uivision sssl rtc,;tNgc 1.-..0c u.-.;., Sz;3. 105 50 rorsytn 6t..eet, xvQ.a, iVivi i:) w..Oc 1VvrtT1 Cup vli..0 z758 -i Auzim :, Georgia 30303-8801 Phone: (404) 562-5137 RIGHT OF ENTRY: Your signature below grants the right of entry to Corps of engineers personnel, and any government consuliants-to conduct investigations or the project site during me course or the ..rr��l 1,Fvee33. Y v!I ;.:n [)e prop:0cd w iJ sa..y notice or -any site ';"ve.,t; ..t:o,., Ila ..:11 nu.c me opportunity to particieate in all site investi ations. Date. Telephone number: Signature of appellant oragent. ro, .-py—t.. P.. y..:t:Rt r..,jf,.....t re—d1s send this form to: u;.tr;,t Engineer, Wilmington Regulatory Division, Attn: David Bailey, 69 Darlingion Avenue, Wilmington, North Curolina 28403 For Perndi denials, Proffered Pernri s and approveu rttriscrietionar uetertititratiotts sena rrrisjorm ro: llivislon B, -.glace. Civm.mrnuc.- U.S. Army Ln.,nares Uiv-67., Svutli Atlantic; AM-..: Mr..lason Steele, Administrative Appeal Unicer- C"FSAL-YUU. SO Fvr..,In St.cct. ma,7M. 191V11.7. All .uta; Gvvi6.w 3VJ9J-11801 1 -none: tu04) 1 rG w:n,.N,5ty.-. LJ,St.-=ct is committed to providing; the highest level of support to the public. To help us ensure we continue to do so, please complete our customer Satisfaction Survey online at littp://reaulatol•N'.usaeesurve},.cont/. Action ID NW,..ber: SAW -2014-01477 County: Rockin hast, Permittee: Duke Energy Progress tattn;_Steve Cahuu.1 Project N..me: Dan Rivei Steam Station 36 inch vive clusu, t: f Eden. Rocidughanifountv IEFURe r.nergy /industrial Date Verification Issued: 04/29/2014 ra o;ect Manager: David Bailey Upon completion of the activity authorized x)y tnis permit and any mitigation required by the permit, sign thi, ce, tification and return it to the following address: US ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT attn: David E. Bailey Raleigh Regulatory Field Office 3331 Heritage Trade Drive, Suite 105 Wako Forest, North Carolina 27587 Please note that your permitted activity is subject to a compliance inspection by a U. S. Army Corps of Enginee. s . zpresentat6c. Failure tu comply with any terms or conditions of this authorization may result in the t ort.a suspending; modifying u, ,evuking the authux;Lation and/ox- issuing a Class I administrative penalty, or initiating uthcr appropriate legal action. I hereby ce, tify that the work authorized by the above referenced permit has been comt.let4d in accurdance with the terms and ca,tdition of the said permit, and required mitigation was completed in accordiince .. ith the permit conditions. Si.,nature of Per.ittee D_.tc