HomeMy WebLinkAbout20090056 Ver 1_DWR Closeout Letter_buffer assets_20170427Water Resources
ENVIRONMENTAL QUALITY
April 27, 2017
Division of Mitigation Services
Attn: Melonie Allen
1652 Mail Service Center
Raleigh, NC 27699-1652
(via electronic mail)
Re: Greenbrier Creek
DMS ID #671—CLOSEOUT ACCEPTANCE LETTER
Dear Ms. Allen,
ROY COOPER
Governor
MICHAEL S. REGAN
Secretnrr
S. TAY ZIMMERMAN
Director
DWR Project # 2009-0056
Alamance & Chatham Counties
On March 22, 2017, the Division of Water Resources (DWR) received a close-out packet from you on
behalf of the Division of Mitigation Services (DMS) requesting approval to close-out the subject site from
monitoring and maintenance of the riparian areas. On April 26, 2017, Mac Haupt (on behalf of Katie
Merritt) with DWR visited the subject site to assess the vegetation and overall site conditions. An asset
map is attached.
As a result of Ms. Merritt's review of the close-out request and site review from Mr. Haupt the following
mitigation is approved:
River Basin/Service Area
Mitigation
Mitigation Ratio
Mitigation Units
Distance from
Type
stream
Cape Fear / Randleman Lake
Buffer
1:1
253,860.75 ft2 —
0-50' top of bank
(grandfathered for location)
Restoration
Buffer Mitigation
TOTAL
253,860.75 ft2
Please feel free to contact Katie Merritt at (919) 807-6371 if you have any questions regarding this
correspondence.
KAH/kym
ATTACHMENTS: Asset Map, Asset Table
cc:
File Copy - Katie Merritt
Sincerely,
Karen iggins, Supervisor
401 & Buffer Permitting Branch
State of North Carolina I Environmental Quality I Water Resources
1617 Mail Service Center I Raleigh, North Carolina 27699-1617
919 807 6300
GREENBRIER CREEK Asset Map
a�
x
r
reach
main
preservation
t trio
Buffer Restoration
Top_of Bank
CVS Plot
Wetlands_delineated_AsBuil
channel
easement
World Imagery
500 250
0
tt
■ Feet
500
Asset Table
Project
Applicable
Credit
Buffer Width
Buffer
Resulting
Notes
Component
Rule
Eligible
Adjustment
Mitigation
Mitigation
9 5 plots/transects
standard
buffer
Credits
Credit Ratio
Units
P 16.93
15:01
(sq. ft.)
All buffer 50 `
2
E= (BMUs)
P (NS, U) = 3
P(S,U)=3
P(NS,R)=5
P(S,R)=10
Tributary -
15A NCAC
56,656.827
NA
1
56,656.827
Upstream of
02B.0250
crossing
Buffer R
Tributary -
15A NCAC
72,976.046
NA
1
72,976.046
Downstream
028.0250
of crossing
Buffer R
Mainstem —
15A NCAC
40,240.407
NA
1
40,240.407
Upstream of
026.0250
Bridge
Buffer R
Mainstem —
15A NCAC
83,987.470
NA
1
83,987.470
Downstream
02B.0250
of Bridge
Buffer R
Totals
253,860.751
2530860.751
Success Criterion
Existing
Restoration
Success Criteria per
Success Criteria Met
Project
(Acres)
Restoration Level
(Acres)
Mitigation
Mitigation
Component
9 5 plots/transects
standard
Ratio
Credits
Wetland
6.93
P 16.93
15:01
1.38
Success Criterion
Project Component
Success Criteria per
Success Criteria Met
Approved Mitigation Plan
Riparian Buffer
320 stems per acre
Yes — 9 out of 11 plots met
9 5 plots/transects
standard