Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NC0024406_Waste Load Allocation_19920309 (2)
NPDES WASTE LOAD ALLOCATION PERMIT NO.: NCooC,�Wo(p FACILITY NAME:_ � DWer /Iele1# Cj^e�,� Facility Status: PROPOSE (circle one) Permit Status: AL MODFIL'.ATlON NEW (circle ons) Major minor,..-_ Pipe No: 00 5 Design .Capacity (MGD): Domestic (X of Flow): O Industrial (% of Flow): /0 Comments: No dam At CO2!411,0,� SSca'J`r as4 se 'l;hQ nom, dt'schz!�e W/ 640m*Lwafo- RECEIVING STREAM: elews Cr� La.� Class: `- Sub -Basin: D 3 -- D A-0 1 Reference USGS Quad: 18 SF (please attach) County: _.5 fo LLes Regional Office: As Fa Mo . Ra Wa WI WS (circle one) Requested Bylp5axne_ Barox ,Date:4 ,-g2 "0 Prepared By: Date:. a` Reviewed By: C. ISJDate: li a1192� Modeler Date Rec..* K)S3 3q2202 (• .2 Drainage Area (ml) Avg. Streamflow (cfs): 7Q10 (cfs)- Winter 7Q10 (efs) 30Q2 (cfs) Toxicity Limits: IWC �_ % Instream Monitoring: Parameters Upstream Location Downstream Location (circle one) Acute / Chronic Effluent Characteristics iN 16C -r .o�I a.I W"/r'yej''d) 6'MD �►� ,..., it �Ien v (WO ; 1#4 Comments: FOR APPROPRIATE DISCHARGERS, LIST COMPLETE GUIDELINE LIMITATIONS BELOW Effluent Characteristics Monthly Average 1.7p Daily Maximum Comments 161L -1d V-ICQ� 0. Ig p, o OUTFALL e005 ' (Abandond) }` O WS LAKE OUTFALL 003 BE(EL.725) +\ DISCHARGE P o� =�rff \ \ TAILINGS POND f r /1 /� j (EL.760) !!! BELEWS CREEK (� STEAM STATION �� '(� !: i /� l� �`^�"! r1 1, C 1J \\ ^ -i ,� Jl�✓ \ N4 r i ROAD CLASSIFICATION PRIMARY HIGHWAY LIGHT-DUTY ROAD, HARD OR HARD SURFACE IMPROVED SURFACE SECONDARY HIGHWAY HARD SURFACE UNIMPROVED ROAD Latitude Longitude Map # 818SE Sub -basin 030201 Stream Class C & WSI_ Discharge Class 14 68 69 70 West Belews ree a ews Lake Receiving Stream & nan River Design Q Variable Permit expires 44&"2 �Z��CJz SCALE 1:24 000 000 FEET 1 1 KILOMETER F__ - E�EE3 CONTOUR QUAD LOCATION Duke Power Company NCO024406 Stokes County Belews Creek Steam Plant A. O. EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS FINAL Permit No. NCO024406 During the period beginning on the effective date of the permit and lasting until expiration, the Permittee is authorized to discharge from outfall(s) serial number 005. Such discharges shall be limited and monitored by the permittee as specified below: Effluent Characterlstic. Discharge Llmltatloni Monitoring Requirements Lbs/day Units (specify Measurement Sample ' ample Mon. Avg. Dally Max Mon, Ayg. Dally Max. Frequency Tvpe Locatlon Flow Weekly Pump Logs" E Oil and Grease 9.09 mg/I 12.12 mg/l 2/Month Grab E Total Suspended Residue 18.18 mg/I 60.6 mg/l 2/Month Grab E Total Arsenic Monthly Grab E Total Selenium 5.0 µg/I 2/Month Grab E Total Nitrogen (NO2+NO3+TKN) Monthly Grab E Total Phosphorus Monthly Grab E Acute Toxicity*** Quarterly Composite E * Sample locations: E Effluent Effluent sampling shall be conducted at the discharge from the ash settling pond prior to mixing with any other waste stream. The coal pile runoff and low volume waste shall be discharged into the settling pond. **Or Similar Readings. ***Acute Toxicity (Ceriodaphnia) 90%, February, May, August, November, See Part III, condition N. The pH shall not be less than 6.0 standard units nor greater than 9.0 standard units and shall be monitored 2/month at the effluent by grab sample. There shall be no discharge of floating solids or visible foam in other than trace amounts. Discharge 005 is. only to be used to augment lake levels and should not be used when the wet ash system is put into operation due to dry ash system upset. These monitoring requirements apply only when there is a discharge to Belews Lake. GKEX88/MP .0000 95/10 08/07/96 95/11 COMPLIANCE EVALUATION ANALYSIS REPORT PAGE 1 PERMIT--NC0024406 PIPE --005 REPORT PERIOD: 9507-9606 LOC ---E .0000 FACILITY --DUKE POWER/BELEWS CREEK STEAM DESIGN FLOW-- 5.0000 CLASS --2 LOCATION --WALNUT COVE REGION/COUNTY--04 STOKES AVERAGE 50050 00530 TGE6C 00400 00556 00600 00665 01002 MONTH Q/MGD RES/TSS FTHD24PF PH OIL-GRSE TOTAL N PHOS -TOT ARSENIC LIMIT NOL F 18.1 9.0 6.0 F 9.090 95/07 .0000 95/08 95/09 .0000 95/10 .0000 95/11 .0000 95/12 .0000 96/01 .0000 96/02 .0000 96/03 .0000 96/04 .0000 96/05 .0000 AVERAGE .0000 MAXIMUM MINIMUM .0000 UNIT MGD MG/L PASS/FAI SU MG/L MG/L MG/L UG/L GKEX88/MP 08/07/96 COMPLIANCE EVALUATION ANALYSIS REPORT PAGE 2 PERMIT--NC0024406 PIPE --005 REPORT PERIOD: 9507-9606 LOC ---E FACILITY --DUKE POWER/BELEWS CREEK STEAM DESIGN FLOW-- 5.0000 CLASS --2 LOCATION --WALNUT COVE REGION/COUNTY--04 STOKES 01147 MONTH SELENIUM LIMIT 95/07 95/08 95/09 95/10 95/11 95/12 96/01 96/02 96/03 96/04 96/05 AVERAGE MAXIMUM MINIMUM UNIT UG/L GKEX88/MP 08/07/96 COMPLIANCE EVALUATION ANALYSIS REPORT PAGE 1 PERMIT--NC0024406 PIPE --005 REPORT PERIOD: 9407-9506 LOC ---E FACILITY --DUKE POWER/BELEWS CREEK STEAM DESIGN FLOW-- 5.0000 CLASS --2 LOCATION --WALNUT COVE REGION/COUNTY--04 STOKES 50050 00530 TGE6C 00400 00556 00600 00665 01002 MONTH Q/MGD RES/TSS FTHD24PF PH OIL-GRSE TOTAL N PHOS -TOT ARSENIC LIMIT NOL F 18.1 9.0 6.0 F 9.090 94/07 .0000 94/08 94/09 .0000 94/10 94/11 94/12 .0000 95/01 .0000 95/02 95/03 95/04 .0000 95/05 .0000 95/06 .0000 AVERAGE .0000 MAXIMUM MINIMUM .0000 UNIT MGD MG/L PASS/FAI SU MG/L MG/L MG/L UG/L GKEX88/MP 08/07/96 COMPLIANCE EVALUATION ANALYSIS REPORT PAGE 2 PERMIT--NC0024406 PIPE --005 REPORT PERIOD: 9407-9506 LOC ---E FACILITY --DUKE POWER/BELEWS CREEK STEAM ' DESIGN FLOW-- 5.0000 CLASS --2 LOCATION --WALNUT COVE REGION/COUNTY--04 STOKES 01147 MONTH SELENIUM LIMIT 94/07 94/08 94/09 94/10 94/11 94/12 95/01 95/02 95/03 95/04 95/05 95/06 AVERAGE MAXIMUM' MINIMUM r UNIT UG/L ,I Facility Name: NPDES No.: Type of Waste: Facility Status: Permit Status: Receiving Stream: Stream Classification: Subbasin: County - Regional Office: Requestor: Date of Request: Topo Quad: FACT SHEET FOR WASTELOAD ALLOCATION Request # Duke Power--Belews Lake --pipe 005 NCO024406 Industrial - 100% Existing Renewal Belews Lake C 03-02-01 RECEIVED Y ED N.C. Dept- of EHNR .;u. 61992 6802Winston--Salem Regional Office Stokes Stream Characteristic: Wiston-Salem Regional Office USGS # Lake Rosanne Barona Date: 3/5/92 Drainage Area (mi2): B18SE Summer 7Q10 (cfs): Winter 7Q10 (cfs): Average Flow (cfs): 30Q2 (cfs): IWC (%): Wasteload Allocation Summary (approach taken, correspondence with region, EPA, etc.) c� Discharge from ash pond with stormwater. Discharge 005 is to be used only to augment lake levels and should not be used when the wet ash system is put into operation due to dry ash system �upset. Monitor only when there is discharge to Belews Lake. 155 6kla r,M4 dAty-I and additional comments from Reviewers: Recommended by: Date: 6 ( � F Z Reviewed by Instream Assessment: Date: Regional Supervisor: %1 Date:�- Permits & Engineering: Date: RETURN TO TECHNICAL SERVICES BY: JUL 3 0 1992 2 TOXICS/METALS/CONVENTIONAL PARAMETERS Type of Toxicity Test: Acute Toxicity No Significant Mortality at 90% Existing Limit: Recommended Limit: Monitoring Schedule: Existin Limits Monthly Ave. Daily Max. WQ or EL Daily Max. Monthly Ave Wasteflow (MGD): Monitor Oil and Grease (mg/1): 4-2-172 qt,L Q. TSS (mg/1)*: -6"- Iq X? 1S4-8 tom, u pH (SU): 6.0-9.0 TP (mg/1): monitor TN (mg/1): monitor Selenium (µg/1): 5.0 Arsenic (µg/1): monitor * Monthly average of 38.18 mg/1 is permitted provided that the permittee can satificatorily demonistrate that the difference between 18.18 mg/1 and 38.18 mg/1 is due to concentration of total suspended solids in the source body. Recommended Limits * Monthly average of 38.18 mg/1 is permitted provided that the permittee can satificatorily demonistrate that the difference between 18.18 mg/1 and 38.18 mg/1 is due to concentration of total suspended solids in the source body. Limits Changes Due To: Change in 7Q10 data Change in stream classification Relocation of discharge Change in wasteflow New pretreatment information Other (onsite toxicity study, interaction, etc.) Parameter(s) Affected Parameter(s) are water quality limited. For some parameters, the available load capacity of the immediate receiving water will be consumed. This may affect future water quality based effluent limitations for additional dischargers within this portion of the watershed. OR X No parameters are water quality limited, but this discharge may affect future allocations. Monthly Ave. Daily Max. WQ or EL Wasteflow (MGD): Monitor Oil and Grease (mg/1): .M iD, 4a 12-12-Q.bc -9- BPJ TSS (mg/l)*: -60:6 ISs.Iq lJd 8'lo,w BPJ pH (SU): 6.0-9.0 EL TP (mg/1): monitor TN (mg/1): monitor Selenium (µg/1): 5.0 Arsenic (µg/1): monitor * Monthly average of 38.18 mg/1 is permitted provided that the permittee can satificatorily demonistrate that the difference between 18.18 mg/1 and 38.18 mg/1 is due to concentration of total suspended solids in the source body. Limits Changes Due To: Change in 7Q10 data Change in stream classification Relocation of discharge Change in wasteflow New pretreatment information Other (onsite toxicity study, interaction, etc.) Parameter(s) Affected Parameter(s) are water quality limited. For some parameters, the available load capacity of the immediate receiving water will be consumed. This may affect future water quality based effluent limitations for additional dischargers within this portion of the watershed. OR X No parameters are water quality limited, but this discharge may affect future allocations. t.r�i•�a INSTREAM MONITORING REQUIREMENTS Upstream Location: Downstream Location: Parameters: Special instream monitoring locations or monitoring frequencies: MISCELLANEOUS INFORMATION & SPECIAL CONDITIONS AAd quacy of Existing Treatment Has the facility demonstrated the ability to meet the proposed new limits with existing treatment facilities? Yes 111111////// No If no, which parameters cannot be met? Would a "phasing in" of the new limits be appropriate? Yes No If yes, please provide a schedule (and basis for that schedule) with the regional office recommendations: If no, why not? Special Instructions or Conditions Effluent sampling shall be conducted at the discharge from the ash settling pond prior to mixing with any other waste streams. Wasteload sent to EPA? (Major) (Y or N) (If yes, then attach schematic, toxics spreadsheet, copy of model, or, if not modeled, then old assumptions that were made, and description of how it fits into basinwide plan) Additional Information attached? (Y or N) If yes, explain with attachments. Facility Name % ry , C�4' ermit # 2 Pipe # �® s ACUTE TOXICITY PASS/FAIL PERMIT LIMIT (QRT�RLY) AW. 70 - The permittee shall conduct acute toxicity tests on a ay= basis using protocols defined in the North Carolina Procedure Document entitled "Pass/Fail Methodology For Detaining Acute Toxicity In A Single Effluent Concentration." The monitoring shall be performed as a F�ead�nnow (Pimephales promelas 24 hour static test, using effluent collected as a 24 hour composite. The effluent concentration at which there may be at no time % (defined as treatment two in the North Carolina procedure document). Effluent significant acute mortality is 90 samples for self-monitoring purposes must be obtained during representative effluent discharge below all waste treatment.afirst test ' ®gerfjeed after thirty days from the effective date of this permit during the months of `d ��-- bb All toxicity testing results required as part of this permit condition will be entered on the Effluent Discharge Monitoring Form (MR -1) for the month in which it was performed, using the parameter code TGE6C. Additionally, DEM Form AT -2 (original) is to be sent to the following address: Attention: Environmental Sciences Branch North Carolina Division of Environmental Management 4401 Reedy Creek Road Raleigh, N.C. 27607 Test data shall be complete and accurate and include all supporting chemical/physical measurements performed in association with the toxicity tests, as well as all dose/response data. Total residual chlorine of the effluent toxicity sample must be measured and reported if chlorine is employed for disinfection of the waste stream. Should any single quarterly monitoring indicate a failure to meet specified limits, then monthly monitoring will begin immediately until such time that a single test is passed. Upon passing, this monthly test requirement will revert to quarterly in the months specified above. Should any test data from either these monitoring requirements or tests performed by the North Carolina Division of Environmental Management indicate potential impacts to the receiving stream, this permit may be re -opened and modified to include alternate monitoring requirements or limits. NOTE: Failure to achieve test conditions as specified in the cited document, such as minimum control organism survival and appropriate environmental controls, shall constitute an invalid test and will require immediate retesting(within 30 days of initial monitoring event). Failure to submit suitable test results will constitute noncompliance with monitoring requirements. 7Q10 cfs Permitted Flow ® MGD Reco by: IWC �- % Basin & Sub -basin —©z-- E> Receiving Stream l.e ujs Date 2c� County S kc c QAL PIF Fathead 24 Version 9191