Loading...
HomeMy WebLinkAbout20170473 Ver 1_SR 1207 Rocky Hock Ck Permits_20170419�LA� vrE �r� DETAILED DRA WI1�lG JUNIUS ALEXANDER COFIELD 637 ROCKY HOCK CREED RD EDENTON, NC 27932 DB 163 / PG 146 EXIST R/W � � � � � � � � i i � � i � i � i � i i' i � i � i � ,'� -�� PROPOSED SHEET PILE � � � ,,' � $ FOR DEWATERING , ,� `�5o4PJ' (OR AQUA BARRIER) ,' .' ,-X / , � �j � � � � 92.4 , � � 6> � U� �1 ° � � G / m O ROGER WHITE 641ROCKY HOCK CREEK RD EDENTON9NC 27932 DB 122 / PG 562 ,� � W�,� PROPOSED 2@ 72" x 38' CAP ��;� � I i I I� WITH HEADWALLS FXICT R iini � l � � ' I � �— - , II II E SR 1207 ROCKY HOCK CREEK RD - �I I I II -I� �I II I ��I II I� �I II II EXISTING 2@ 24" X 36' RCP & � I I! I' 2@ 42" X 44' CMP � �� i - �.s,�_�r,_,��r,.� .�, _r,_ -� �+���'-Pn � - N O� T�,�� � ,--�_��; r �-�-�`=-r- EXIST R/W � `s' \ o NO WETLAND IMPACT NO OPEN WATER IMPACT LEGEND - - - EXISTING PROPOSED PROPOSED SHEET PILE FOR DEWATERING � (OR AQUA BARRIER) / X 91.15'. rr r� FRANCES W BYRUM 634 ROCKY HOCK CREEK RD EDENTON, NC 27932 DB 270 / PG 540 *NOTE: EXACT LOCATION OF WATERLINE YET TO BE DETERMINED. n� �eii �c Tn Rn��v Nn�� Rn —� �n� EXIST R/W PROPOSED RIP RAP �r-fr-- _ _ I� I� I� I� I� I� �� �� �� �� ------I�L—�� PROPOSED PIPE BED DETAIL SECTI01� VARIABLE CR OSS SECTI01� � � � 20'-0" �----------T---------- I I EXIST. WATER LEVEL ====a=___ ______________ VARIABLE PROPOSED RIP RAP � � EXISTING I 2@ 42" x 44' CMP ----^------- �2 @-24' x 36�RCP �:���--..__��_ EXIST. STREAM BED �. pROPOSED 2@ 72" x 38' CORRUGATED ALUMINUM PIPE WITH HEAD WALLS ---�-� I� I� I� I� I� I� �� �� �� �� .._.�� � -- _ EXIST. PIPE BED NOTES: * PROPOSED 2@ 72" x 38' CORRUGATED ALUMINUM PIPE WITH HEADWALLS TO BE BURIED 1.0' BELOW EXISTING STREAM BED * ALL ELEVATIONS BASED ON ASSUMED DATA PROPOSED RIP RAP �_ _ _ _ � � o _ // EXISTING 4 OF PAVEMENT 'IOO.00� PROPOSED FILL _ � � _ _ _ _ _ � _ _ _ _ _ _ � _ _ _ _ _ � � _ _ � j/ � _ _ _ _ _ � / �— �—� � \ \ WATER LEVEL 95.40' I / EXISTING // 24" X 36' RCP\ EXISTING PIPE BED 92.55'� \ EXISTING 2 @ 42" X 44' CMP � � I I � � _ \\ � \ I I/ \ EXISTING � ` I 24" X 36' RCP _ �/ _ _ _� STREAM BED 92.00_ PROPOSED PIPE BED 91.00' �� PROPOSED � 2@ 72" x 38' CAP WITH HEADWALLS NOTE: PROPOSED 2@ 72" x 38' CORRUGATED ALUMINUM PIPE WITH HEADWALLS TO BE BURIED 1.0' BELOW EXISTING STREAM BED DETAIL SECTI01� - O UTLET E1�D VIEW SYMBOLS PROPOSED CROSS SECTI011t — — — — — — EXISTI11tG CROSS SECTI0111 NORTH CAROLINA DEPARTMENT OF TRANSPORTATION DIVISION 1 113 AIRPORT DR. EDENTON, NC 27932 (252) 482-1850 COUNTY: CHOWAN WBS#: DF15001.2021010 QUAD: VALHALLA DATE: OCTOBER 27, 2016 BASIN: CHOWAN SHEET #: 2 OF 2 REPLACE PIPE CULVERT ON SR 1207 ROCKY HOCK CREEK RD LAT. = 36.139732 N LONG. = 76.679931 W DRAWN BY: R.G. WEST SCALE: 1" = 5'